CAUTION<br />

Lead size should be determined taking into account voltage drop of leads. Voltage<br />

drop can be obtained by the following equation: select such lead size that voltage<br />

drop will be within 2% of normal rated voltage.<br />

phase-to-phase voltage drop (V)<br />

= 3 x lead resistance ( Ω /km) X wiring distance(m) x current(A) X 10 -3 .<br />

Wiring length between inverter and motor.<br />

If total wiring distance between inverter and motor is excessively long and inverter<br />

carrier frequency (main transistor switching frequency) is high, harmonic leakage<br />

current from the cable will increase to effect the inverter unit or peripheral devices.<br />

If the wiring distance between inverter and motor is long, reduce the inverter<br />

carrier frequency.<br />