03.03.2013 Views

ATMOS S 61 Servant ENT workstation

ATMOS S 61 Servant ENT workstation

ATMOS S 61 Servant ENT workstation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Top-class <strong>ENT</strong> diagnostic and therapy system<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

The new „<strong>Servant</strong>“<br />

15


Design<br />

Your patients should feel<br />

comfortable in your practice.<br />

An appealing design and a wide<br />

choice of colours create<br />

a pleasant surrounding.<br />

Ergonomics<br />

All functions of the treatment unit are<br />

readily accessible and enable an efficient<br />

workflow. By the modular construction<br />

all important functions and handles are<br />

perfectly arranged and provide ergonomic<br />

working conditions.<br />

Price performance<br />

You only choose the functions you really need.<br />

Thus – even with a low budget you get<br />

the required treatment unit.<br />

16<br />

The special features<br />

of the new <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Mobility<br />

Mobility due to the castors which are located<br />

on the rear of the device, this enables an<br />

easy cleaning of the examination room.


<strong>ATMOS</strong> sets new standards<br />

with regard to:<br />

Modularity/<br />

Use of space<br />

The amount of space in the <strong>ENT</strong><br />

outpatient department is becoming<br />

increasingly limited. However, you<br />

do not want to limit your treatment<br />

possibilities. The modular concept of<br />

the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> guarantees<br />

the perfect use of space.<br />

Hygiene<br />

Hygiene starts with the concept<br />

of the treatment unit.<br />

- Clear separation between clean<br />

and contaminated area<br />

- Instrument management<br />

- Endoscope management with<br />

control of disinfection time<br />

are only some features.<br />

Maintainability/<br />

Retrofitting<br />

The most important functions of the treatment unit are<br />

electronically-controlled. The service displays indicate in<br />

due time the exchange of consumables. With it unexpected<br />

breakdown is prevented.<br />

Later it is also possible to retrofit different modules of your<br />

<strong>workstation</strong>. The upgrade is performed on site by an <strong>ATMOS</strong><br />

technician.<br />

MedizinTechnik<br />

17


18<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

the „module system“<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> –<br />

Definitely a good decision!<br />

You know exactly which services you<br />

would like to offer your patients but your<br />

budget is limited. The modularity of the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> enables the perfect<br />

configuration of your treatment unit.<br />

The amount of space in the <strong>ENT</strong><br />

outpatient department is becoming<br />

increasingly limited. However, you do not<br />

want to limit your treatment possibilities.<br />

The modular concept of the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> guarantees the<br />

perfect use of space.<br />

You established an individual treatment<br />

method and now you need an individual<br />

positioning of the different functions in<br />

your treatment unit – take advantage of<br />

the design alternatives offered by the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>.<br />

Yet again you have to move clinics.<br />

The clinic space or the functions required<br />

for treatment have changed.<br />

Why purchase a completely new<br />

treatment system?<br />

The modular concept and retrofitting<br />

possibilities of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

allow your equipment specification to be<br />

upgraded at a favourable price.<br />

0124<br />

Besides the basic equipment images and specifications<br />

also contain optional functions.<br />

2<br />

6<br />

3


4<br />

Innovation to suit every room<br />

and every budget!<br />

1<br />

5<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

MedizinTechnik<br />

The new <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

The complete solution from<br />

<strong>ATMOS</strong> consisting of:<br />

- <strong>ENT</strong> <strong>workstation</strong><br />

- vision<br />

- instruments<br />

- therapy<br />

- system<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong><br />

<strong>workstation</strong><br />

- Suction equipment<br />

- Ear irrigation / thermal<br />

nystagmus stimulation<br />

- Compressed air<br />

- Light module / economy<br />

- Instrument management<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

- Light modules<br />

- Headlights<br />

- Endoscope management<br />

- <strong>ENT</strong> camera<br />

- LED Stroboscope<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

- Waste bin<br />

- Bowl for used instruments<br />

- Drawers<br />

- Instrument management<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

- Writing surface<br />

- RF surgical device<br />

- Smoke evacuation system<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

- Microscope<br />

- Instrument deposit<br />

- Monitor board<br />

- Monitor arm<br />

- Diagnostics board<br />

Steel housing<br />

Buying an <strong>ENT</strong> treatment<br />

unit is an investment for<br />

many years. Rely on the<br />

long service life of the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>.<br />

19


20<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

Suction Irrigation Compressed Air / Sprayer<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

The <strong>ATMOS</strong> S<strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> Workstation<br />

is the centerpiece of the new <strong>ENT</strong> treatment<br />

system and with its modular design it offers<br />

optional all the functions you need for the<br />

treatment of your patients.<br />

n Powerful suction system<br />

n Ear irrigation module<br />

n Thermal nystagmus stimulation<br />

n Compressed air system for nebulization<br />

of medications<br />

n Innovative LED light module for headlight and<br />

light source<br />

n Instrument deposit and mirror heating<br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

is designed for the demanding use in clinic<br />

and practice.<br />

n The solid steel housing provides the<br />

necessary sturdiness<br />

n High-quality material and lacquers which<br />

withstand the heavy-duty requirements<br />

(disinfectant solutions) in the outpatient<br />

department<br />

n Mobility due to the castors which are located<br />

on the rear of the device, enable easy<br />

cleaning of the examination room.<br />

The design of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong> makes your patients feel<br />

comfortable in your practice. All the technical<br />

equipment is well hidden behind an appealing<br />

housing – however, all important functions and<br />

handles are perfectly arranged and provide<br />

ergonomic working conditions. Regarding<br />

colouring you may choose between more than<br />

200 colours, so the system can be tailored to<br />

match your existing examination room.<br />

Depending on the requirements, it is possible<br />

to optionally upgrade the different modules, in<br />

order for you to adapt your workflow according<br />

to the increased patient through-put (automatic<br />

rinsing, instrument warming, and further<br />

modules from the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> line).<br />

This saves time and money.<br />

You can configure your treatment system by<br />

selecting function modules for the treatments<br />

you wish to carry out. After your initial system<br />

has been purchased, it is possible to upgrade<br />

the functionality of your unit if required.<br />

This can be performed on site by an <strong>ATMOS</strong><br />

engineer so allows you to adapt your system to<br />

meet your changing clinic requirements.<br />

0124<br />

8<br />

9<br />

4<br />

Besides the basic equipment images and specifications<br />

also contain optional functions.<br />

10 9<br />

Hidden technology<br />

All functions of the<br />

treatment unit are<br />

readily accessible and<br />

enable an efficient<br />

workflow.<br />

2<br />

3<br />

5<br />

1<br />

4<br />

6<br />

3<br />

10<br />

Design is important!<br />

7<br />

Your patients should feel<br />

comfortable in your practice.<br />

An appealing design and<br />

a wide choice of colours<br />

create a pleasant surrounding.


Basic equipment and options<br />

8<br />

Clipboard<br />

The clipboard expands<br />

the storage space for<br />

instruments and is the<br />

perfect connection to<br />

further <strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> modules. The<br />

angled arrangement<br />

guarantees ergonomic<br />

working. The doctor<br />

remains in the centre of<br />

events.<br />

7<br />

autostart<br />

Light module Economy<br />

The <strong>ATMOS</strong> LED technology<br />

enables the use of highperformance<br />

LED headlight and<br />

LED light handle – without any<br />

light conducting cable.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

Autostart function<br />

MedizinTechnik<br />

When the suction hose is removed,<br />

from the docking station the suction will<br />

be automatically activated. Miniaturized<br />

light barriers control most part of the<br />

basic functions of the <strong>ATMOS</strong> S <strong>61</strong><br />

<strong>ENT</strong> <strong>workstation</strong>. Time is therefore used<br />

more efficiently with the removal of<br />

manual switching of the light source.<br />

DDS secretion container<br />

Thanks to the Direct Docking System<br />

(DDS) it is possible to exchange the<br />

secretion container with one pull. The<br />

bacterial filter prevents you from bad<br />

odours in the surroundings of the<br />

treatment unit and the inner workings<br />

from contamination.<br />

Ear irrigation /<br />

thermal nystagmus stimulation<br />

The ear irrigation (Hygrotherm<br />

module) resp. the caloric stimulation<br />

of the vestibular organ (Variotherm<br />

module) is performed quickly thanks<br />

to the automatic switching and the<br />

ear rinsing bowl with its own suction<br />

channel.<br />

Nebulization of medications<br />

(compressed air)<br />

Single-handed adaptation of the<br />

sprayer bottles and the automatic<br />

switching enable a time-saving<br />

and hygienic use of medication<br />

sprayers.<br />

Heating module for<br />

instrument tray<br />

One instrument tray has a heating<br />

module for instrument pre-heating<br />

to body temperature. Your patients<br />

will appreciate this.<br />

Mirror quick heating<br />

At one key press mirror heating is<br />

available. This prevents fogging and<br />

guarantees a free vision.<br />

21


22<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

Light sources Endoscopes Camera Stroboscopy<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision –<br />

The professional visualisation<br />

system from <strong>ATMOS</strong><br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision sets a new<br />

standard in the professional visualisation for<br />

the <strong>ENT</strong> workplace. With its modular design<br />

it offers optional all the functions one requires<br />

from a modern endoscopy <strong>workstation</strong>:<br />

n Light module with conventional cold light<br />

technology with the option of innovative<br />

LED technology<br />

n Headlights with automatic light switching<br />

n Smooth endoscope management<br />

n Integrated <strong>ENT</strong> camera with connection to<br />

PC archiving system<br />

n Integrated LED stroboscopy for<br />

larynxdiagnostics<br />

n Storage space for instruments and<br />

medication bottles<br />

The <strong>ATMOS</strong> S <strong>61</strong> Vision sets itself above<br />

other <strong>ENT</strong> systems due to its:<br />

n Sophisticated design<br />

n Sturdy steel housing<br />

n High-quality material, most important when<br />

using aggressive disinfectant solutions<br />

n Later upgrade of all modules, performed on<br />

site by an <strong>ATMOS</strong> service technician<br />

n Extensive service information which prevent<br />

unexpected breakdown of functions<br />

The sophisticated modular concept of the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> Vision allows the<br />

system to be operated as a standalone<br />

<strong>ENT</strong> treatment unit<br />

0124<br />

2<br />

6<br />

10 9<br />

7<br />

Besides the basic equipment images and specifications<br />

also contain optional functions.<br />

8<br />

Placement area for<br />

bottles/<br />

instrument trays<br />

For storage of<br />

medication bottles<br />

and higher objects.<br />

Optionally to be<br />

covered with an<br />

instrument tray.<br />

5<br />

3<br />

10<br />

4<br />

Swab area<br />

The endoscope<br />

management<br />

includes a swab area.<br />

Here disinfectant<br />

solution, water and<br />

anti-fogging agent<br />

can be wiped off<br />

from scopes prior<br />

to their use.<br />

The cotton strip<br />

is easy to exchange.


8<br />

Features and options<br />

4<br />

7<br />

8<br />

Quiver for used<br />

endoscopes /<br />

disinfection time<br />

monitoring<br />

In case used endoscopes<br />

are not directly brought to<br />

sterilisation, it is possible<br />

to store them in a plastic<br />

quiver, which, if requested,<br />

can be filled with disinfectant<br />

solution. Optionally available<br />

is an electronic stop watch<br />

function which can be<br />

activated at one key press.<br />

And this shows the duration<br />

of disinfection by means of an<br />

LED indicator light.<br />

9<br />

9<br />

10<br />

6<br />

7<br />

Quiver for clean<br />

endoscopes<br />

autostart<br />

Clean endoscopes can be<br />

stored in a heated metal<br />

quiver, there they are to<br />

hand for examinations, if<br />

required, with connected<br />

light conducting cable.<br />

Sleeves are available for the<br />

protection of the endoscopes<br />

when inserted quickly.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

MedizinTechnik<br />

Innovative LED light handle<br />

<strong>ATMOS</strong> LS 21 LED<br />

The innovative LED light handle<br />

<strong>ATMOS</strong> LS 21 LED features the<br />

high-performance white-light<br />

LED with an almost unlimited<br />

service life. The light source<br />

is directly connected to the<br />

endoscopes, therefore expensive<br />

and damageable light conducting<br />

cables are no longer needed.<br />

Innovative LED headlight<br />

<strong>ATMOS</strong> HL 21 LED<br />

The innovative LED headlight<br />

<strong>ATMOS</strong> HL 21 LED makes your life<br />

easier: Maximum illumination with<br />

white light at a minimum weight of<br />

the headlight and cable because no<br />

light conducting cable is needed. The<br />

use of miniature Li-ionic batteries<br />

makes you – if required – completely<br />

independent from the treatment unit.<br />

Even the LED headlight has an almost<br />

unlimited lamp service life.<br />

High-performance halogen<br />

cold light<br />

The integrated electronic soft start<br />

function guarantees maximum<br />

lamp service life at maximum<br />

light performance. An average<br />

lamp service life of 300h is selfexplanatory.<br />

Integrated <strong>ENT</strong> camera<br />

The integratable camera module<br />

<strong>ATMOS</strong> Cam 21 / Cam 31 features<br />

n Easy to operate<br />

n One-hand adaptation to endoscope<br />

and microscope<br />

n Integrated image memory with foot<br />

switch function<br />

n 2 Analogue video outlets<br />

n Digital video outlet (DV) for top<br />

quality archiving on PC<br />

Automatic switching<br />

When an endoscope is taken out<br />

from the quiver, the illumination<br />

is switched on and the camera<br />

is automatically adapted to the<br />

relevant endoscope and light<br />

parameters – it cannot be easier.<br />

Integrated<br />

stroboscope <strong>ATMOS</strong><br />

Strobo 21 LED<br />

Due to LED technology<br />

a stroboscopic<br />

examination performed<br />

with the treatment<br />

unit is as easy as the<br />

standard endoscopic<br />

larynx diagnostics.<br />

High-performance<br />

white-light LED<br />

and a sophisticated<br />

microphone electronics<br />

quickly provide a<br />

display of the mucosal<br />

wave.<br />

23


24<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Instruments Deposit of used instruments<br />

Writing surface Waste bin<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments –<br />

Efficient instrument management!<br />

Less is more!<br />

Efficient instrument management saves<br />

valuable time and enables you to meet<br />

strict hygienic requirements even in times of<br />

increased patient volumes.<br />

n Clear separation between clean and dirty<br />

areas (waste bin, bowl for used instruments)<br />

n Quick and easy exchange of the bowl for<br />

used instruments, even when filled with<br />

disinfectant solution<br />

n The systematic arrangement of large and<br />

small trays made of different materials<br />

(stainless steel, aluminium, melamine)<br />

ensures optimum instrument placement<br />

n The closable roller-shutter cover protects the<br />

instruments<br />

n Consumables, rarely needed instruments,<br />

etc. can be stored in the drawers<br />

For protecting your high-quality instruments,<br />

the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments can<br />

optionally be equipped with a central locking<br />

system. A lockable roller shutter cover is an<br />

available option.<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy –<br />

Radiofrequency surgery<br />

in the <strong>ENT</strong> practice<br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> Therapy module<br />

is particularly suitable for integrating a<br />

radiofrequency surgical device into the<br />

<strong>ENT</strong> <strong>workstation</strong>.<br />

The radiofrequency surgical device<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong> can optionally be<br />

integrated in a drawer. When the drawer is<br />

opened, all important control elements and<br />

handles with electrodes are at hand and are<br />

ready for use. The innovative radiofrequency<br />

technology is suitable for haemostasis<br />

(coagulation) as well as for the perfect cutting<br />

of tissue with less scarring (nasal concha).<br />

Radiofrequency surgery with bipolar electrodes<br />

is used in snore therapy (uvulopalatoplasty).<br />

Safety has priority<br />

The <strong>ATMOS</strong> SE 6501 Smoke Evacuation<br />

System module can be integrated within the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy so that it can<br />

be easily accessed when suction of infectious<br />

aerosols is required.<br />

0124<br />

8 7<br />

Smoke evacuation<br />

For suction of<br />

infectious aerosols,<br />

it is possible<br />

to integrate the<br />

smoke evacuation<br />

module <strong>ATMOS</strong> SE<br />

6501 into the <strong>ATMOS</strong><br />

S <strong>61</strong> therapy.<br />

5<br />

4<br />

5<br />

3<br />

6<br />

2<br />

Radiofrequency<br />

surgery<br />

The integration of the<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong><br />

in the <strong>ATMOS</strong><br />

S <strong>61</strong> <strong>Servant</strong><br />

therapy enables<br />

easy application<br />

of radiofrequency<br />

surgery in the<br />

<strong>ENT</strong> outpatient<br />

department.


<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Radiofrequency surgery<br />

Smoke evacuation<br />

6<br />

Besides the basic equipment images and specifications<br />

also contain optional functions.<br />

1<br />

Drawer (airmatic)<br />

The modular construction<br />

of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

instruments enables an<br />

individual configuration of<br />

your required instruments.<br />

The basic version has<br />

one drawer made of steel.<br />

Drawers with airmatic<br />

function are optionally<br />

available. A slight push on<br />

the drawer front and it will<br />

close automatically so you<br />

can concentrate fully on your<br />

patient.<br />

8<br />

7<br />

2<br />

5<br />

Waste bin<br />

The waste bin is easy to<br />

open with a light push via the<br />

kick-plate on the drawer front.<br />

The waste bin makes disposal<br />

simple and has a high capacity.<br />

1<br />

2<br />

3<br />

4<br />

Roller-shutter cover<br />

MedizinTechnik<br />

The roller-shutter cover for the<br />

instrument deposit protects<br />

your instruments from dust and<br />

contamination. In order to protect<br />

your precious instruments from theft,<br />

the roller-shutter cover is optionally<br />

lockable.<br />

Retractable writing surface<br />

Sometimes you may wish to take<br />

notes at the <strong>ENT</strong> workplace, this<br />

is possible by the extendable,<br />

stainless steel writing surface<br />

which is integrated below the<br />

instrument deposit.<br />

Mirror pre-heating<br />

The heated mirror magazine has<br />

space for approx. 70 mirrors (size<br />

K2 to K7). In order to prevent<br />

the mirrors from fogging the<br />

magazine is pre-heated to body<br />

temperature (38°C).<br />

Deposit for used instruments<br />

After use on the patient you would<br />

like to quickly remove instruments<br />

from your working area and have<br />

them disinfected. The bowl for<br />

used instruments is spacious and<br />

readily accessible. It is integrated<br />

in a drawer and is therefore easy<br />

to exchange, but at the same time<br />

it is well hidden and not visible for<br />

the patient.<br />

In case you prefer to deposit the<br />

used instruments in disinfectant<br />

solution you will appreciate the<br />

covered bowl made of plastic.<br />

On request all parts which may<br />

become splashed are available in<br />

stainless steel.<br />

25


26<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system –<br />

The „functional frame“!<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

Offers maximum service directly<br />

at the treatment unit!<br />

1. The integration of the <strong>ENT</strong> examination<br />

microscope has approved:<br />

n Perfect operation comfort<br />

n Fully independent from clinic room<br />

2. Extended instrument placement area<br />

High patient volumes require sufficient<br />

instrument storage capacity. Even rarely<br />

used instruments can be within reach.<br />

3. Diagnostic devices at the <strong>workstation</strong><br />

In order to save time many examinations are<br />

performed directly at the treatment unit.<br />

n Ultrasound<br />

n Tympanometry<br />

n OAE<br />

There are storage shelves close to the<br />

patient, therefore devices can easily be<br />

integrated in the work area.<br />

0124<br />

6<br />

5<br />

Besides the basic equipment images and specifications<br />

also contain optional functions.<br />

9 8<br />

Metal shelf<br />

For integration of<br />

additional diagnostic<br />

devices, for<br />

example, ultrasound,<br />

tympanometer, OAE,<br />

in the work area.<br />

3<br />

1<br />

1<br />

4<br />

Glass shelf<br />

8 9<br />

High-quality shelf with<br />

an appealing design.<br />

2


The ideal add-on to the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> modules<br />

7<br />

7<br />

Instrument deposit<br />

More space for<br />

instrument storage.<br />

The roller-shutter<br />

cover protects the<br />

instruments from dust<br />

and contamination. If<br />

requested, a lockable<br />

version is available.<br />

6<br />

Monitor arm<br />

professional<br />

autostart<br />

Due to the design of the<br />

professional monitor arm,<br />

the TFT screen can be<br />

easily positioned in front<br />

of the microscope column<br />

for demonstration or<br />

beside the patient during<br />

examination.<br />

1<br />

2<br />

3<br />

4<br />

5<br />

System frame<br />

MedizinTechnik<br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

enables the perfect extension of your<br />

treatment unit with examination<br />

microscope, further placement<br />

areas for instruments, shelves and<br />

monitor supports.<br />

Microscope<br />

The integration of a high-quality<br />

examination microscope offers many<br />

advantages:<br />

- Sturdy, vibration-free suspension<br />

- Independent from room conditions<br />

even when moving within the<br />

practice/clinic<br />

Automatic switching<br />

When pulling at the microscope<br />

to bring it close to the patient, the<br />

illumination of the examination field<br />

is automatically activated.<br />

Camera adapter<br />

The camera, integrated in the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision, can be<br />

easily adapted with a beam splitter.<br />

This enables visualisation of the<br />

examination on the monitor and<br />

archiving on the computer.<br />

TFT monitor on console<br />

Flat TFT monitor with medical<br />

approval.<br />

27


MedizinTechnik<br />

Standard colour: ocean<br />

(RAL 5005 signal blue)<br />

1) Further colours for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>:<br />

sapphire (RAL 5003 sapphire)<br />

terra (RAL 2001 red-orange)<br />

coco (RAL 1015 light-ivory)<br />

apple (RAL 6019 white-green)<br />

basic (RAL 7046 grey)<br />

turquoise (RAL 5018 turquoise)<br />

28<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Basic equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> 230 V<br />

Consisting of:<br />

Basic <strong>ENT</strong> treatment unit for modular configuration of suction equipment, ear<br />

irrigation, compressed air system and LED light system.<br />

n Sturdy steel casing, dimensions: H 883 x W 412 x D 540 mm<br />

n Instrument deposit with 2 trays (190 x 150 mm)<br />

Trays are not included in delivery!<br />

n Mobility due to 2 castors on the rear of the device<br />

n Standard colour: Ocean (RAL 5005, signal blue)<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

l Suction equipment<br />

l Ear irrigation / thermal<br />

nystagmus stimulation<br />

l Compressed air<br />

l Light module economy<br />

l Instrument management<br />

l Supply modules<br />

The smallest complete<br />

<strong>ENT</strong> <strong>workstation</strong> which<br />

we know!<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

Besides the basic equipment images<br />

and specifications also contain optional<br />

functions.<br />

REF<br />

530.0000.0<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> 100 V 530.0001.0<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> 115 V 530.0002.0<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> 127 V 530.0003.0<br />

Clipboard<br />

for lateral expansion/connection of working surface<br />

n Instrument deposit with 1 tray (150 mm x 190 mm)<br />

n Holder for suction hose respectively LED light source<br />

Further colours for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Select your colour for the housing from 6 different RAL colourings<br />

(see colour samples 1) )<br />

Special lacquering<br />

There are more than 200 different colours available (RAL colour samples).<br />

Additional price for colours other than standard.<br />

Structural lacquer<br />

Smooth lacquer<br />

Variations of the imaged colour samples and the original colour are possible.<br />

Please ask for our pattern card!<br />

530.0010.0<br />

530.0020.0<br />

530.0021.0<br />

530.0022.0


Options for suction equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Suction equipment<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

REF<br />

The suction equipment of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

can be adapted individually to your requirements and ambient conditions:<br />

Suction pumps are available in two performance classes (standard/<br />

professional), or if available you can use the central vacuum supply in your<br />

clinic. Due to the DDS (Direct Docking System), the secretion collection<br />

container of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> is easy to be<br />

exchanged and easy to clean, especially in combination with the optionally<br />

automatic hygiene module. This module enables an easy cleaning of<br />

the complete secretion way. A wide range of usual disposable container<br />

systems are available in case you decided in favour of single-use systems.<br />

Suction system standard 40 l/min<br />

complete with suction hose, cannula adapter,<br />

DDS secretion container with overflow protection and<br />

bacterial filter<br />

n Almost noiseless<br />

n Standard suction performance (40 l/min, -76 kPa)<br />

n Secretion container lid<br />

n Secretion collection container (1.0 l) with mechanical<br />

overflow protection and bacterial filter<br />

n User-friendly automatic start-up, when removing the<br />

cannula adapter from the support<br />

Included in delivery:<br />

1 x hose adapter set; 1 x suction hose; 1 x secretion container 1.25 l;<br />

secretion container lid<br />

Suction system professional 55 l/min<br />

complete with suction hose, cannula adapter,<br />

DDS secretion container with overflow protection and<br />

bacterial filter<br />

n Extremely noiseless<br />

n Maximum suction performance (55 l/min, -98 kPa)<br />

n Secretion container lid<br />

n Secretion collection container (1.0 l) with mechanical<br />

overflow protection and bacterial filter<br />

n User-friendly automatic start-up, when removing the<br />

cannula adapter from the support<br />

Included in delivery:<br />

1 x hose adapter set; 1 x suction hose; 1 x secretion container 1.25 l;<br />

secretion container lid<br />

Suction equipment for connection to<br />

central vacuum supply<br />

complete with suction hose, cannula adapter,<br />

DDS secretion container with overflow protection and<br />

bacterial filter<br />

n Extremely noiseless<br />

n Secretion container lid<br />

n Secretion collection container (1.0 l) with mechanical<br />

overflow protection and bacterial filter<br />

n Protection of the central vacuum supply against<br />

overflow and contamination<br />

n User-friendly autostart, when removing the cannula<br />

adapter from the support<br />

n Standard NIST-Vac connection on the rear of the<br />

device<br />

Connecting hose is not included in delivery!<br />

Included in delivery:<br />

1 x hose adapter set; 1 x suction hose; 1 x secretion container 1.25 l;<br />

secretion container lid<br />

530.1010.0<br />

530.1020.0<br />

530.1030.0<br />

29


MedizinTechnik<br />

<br />

<br />

30<br />

Options for suction equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Options for suction equipment<br />

Control and display of suction performance<br />

Display of negative pressure (vacuum gauge) and control<br />

of suction performance with rotating knob at the front<br />

panel<br />

Hose rinsing (hygiene module)<br />

with manual filling<br />

To prevent blockages and bad odour in the suction<br />

system. Enables easy, regular cleaning of the suction<br />

hose, respectively the suction ways without splashes<br />

(integrated splash protection), and includes a readily<br />

accessible water storage container in the service<br />

compartment. When touching the cannula adapter with<br />

the rinsing adapter the complete suction way is cleaned<br />

automatically.<br />

Included in delivery:<br />

1 x <strong>ATMOS</strong> special cleanser (REF 080.0005.0)<br />

Manual hose rinsing (hygiene module) with fullyautomatic<br />

filling system for water storage container<br />

for an interrupt-free use of the hose rinsing system.<br />

Water supply system (REF 530.2040.0) or a water<br />

connection module (REF 530.2050.0) are required.<br />

Included in delivery:<br />

1 x <strong>ATMOS</strong> special cleanser (REF 080.0005.0),<br />

1 x rinsing container 1.25 l.<br />

Automatic secretion container evacuation<br />

for an interrupt-free use of the suction system because<br />

the secretion collection container is emptied at regular<br />

intervals. Water drainage system (REF 530.2060.0) is<br />

required.<br />

Optional foot switch for<br />

suction/compressed air system<br />

Start/stop function for suction/compressed air system,<br />

which enables an accurate start-up of the compressed<br />

air system and the suction system via foot switch.<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

l Suction equipment<br />

l Ear irrigation / thermal<br />

nystagmus stimulation<br />

l Compressed air<br />

l Light module economy<br />

l Instrument management<br />

l Supply modules<br />

REF<br />

530.1040.0<br />

530.1050.0<br />

530.1060.0<br />

530.1070.0<br />

530.1080.0


Options for suction equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Optional disposable secretion management<br />

Adapter to connect Receptal ® secretion containers<br />

n For easy put on of Receptal ® containers<br />

n Hidden in the service compartment - suitable for<br />

Receptal ® 1,0 l<br />

Included in delivery:<br />

1 x Receptal ® container 1 l; 1 x Receptal ® bag 1 l<br />

Adapter to connect Medi-Vac ® secretion containers<br />

n For easy put on of Medi-Vac ® containers<br />

n Hidden in the service compartment - suitable for<br />

Medi-Vac ® 1,0 l<br />

Included in delivery:<br />

1 x Medi-Vac ® external container 1 l; 1 x Medi-Vac ® internal cont.1 l<br />

Adapter to connect Serres secretion containers<br />

n For easy put on of Serres containers<br />

n Hidden in the service compartment - suitable for<br />

Serres 1,0 l<br />

Container and bag are not included in delivery!<br />

Consumables for disposable secretion management<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

REF<br />

530.1090.0<br />

530.1092.0<br />

530.1095.0<br />

Receptal ® bag 1 l, not autoclavable, 50 pcs. 312.0463.0 *<br />

Receptal ® external container 1 l 312.0464.0<br />

Disposable hose, not autoclavable, 10 pcs. 006.0058.0<br />

Consumables for the suction system<br />

Bacterial filter for secretion container<br />

Prevents bacterial contamination of the ambient air caused<br />

by bacteria in the secretion container respectively the<br />

suction aggregate (10 pcs.)<br />

<strong>ATMOS</strong> special cleanser for suction ways<br />

Concentrate to be added to the water storage container.<br />

For efficient hose cleaning, protects against residues and<br />

bad odour (100 ml).<br />

340.0054.0<br />

080.0005.0<br />

31


MedizinTechnik<br />

<br />

<br />

32<br />

Temp<br />

37<br />

set<br />

36-38°C<br />

°C<br />

Hygrotherm<br />

Options and accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Ear irrigation / Thermal nystagmus stimulation<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

l Suction equipment<br />

l Ear irrigation / thermal<br />

nystagmus stimulation<br />

l Compressed air<br />

l Light module economy<br />

l Instrument management<br />

l Supply modules<br />

REF<br />

In the <strong>ENT</strong> field tempered water is applied in two fields:<br />

n Ear irrigation at body temperature for removal of cerumen<br />

n Caloric stimulation of the vestibular system at variable temperatures<br />

The ear irrigation module 37°C professional (Hygrotherm) provides up<br />

to 500 ml/min water at the right temperature. The ear irrigation module<br />

37°C basic is a more simple version.<br />

For the nystagmus stimulation the module Variotherm plus is used.<br />

Here the auditory canal is irrigated for a limited time with water,<br />

having a temperature between 20°C and 47°C, for thermal nystagmus<br />

stimulation.<br />

Ear irrigation<br />

Ear irrigation module 37°C professional<br />

(Hygrotherm)<br />

Warm water irrigation module with irrigation handle,<br />

exchangeable jet connection, splash protection, fineadjustment:<br />

Flow adjustable from 50 up to 500 ml/min.<br />

Temperature adjustable between 36°C and 38°C.<br />

Continuous availability due to connection to the water<br />

supply. All parts are autoclavable. Water supply system<br />

(REF 530.2040.0) or water connection system<br />

(REF 530.2050.0) and water drainage system<br />

(REF 530.2060.0) are required.<br />

Ear irrigation module 37°C basic<br />

Warm water irrigation system for connection to the suction<br />

system. Two heated water storage containers 250 ml, and<br />

control thermometer.<br />

(Not in combination with the suction system<br />

professional 55 l/min, REF 530.1020.0)<br />

530.2020.0<br />

530.2010.0<br />

Ear irrigation module compressed air 530.2080.0<br />

For technical data please see page 59!


Options and accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Thermal nystagmus stimulation (water)<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Thermal nystagmus stimulation (Variotherm)<br />

Warm water module with quick, electronically-controlled<br />

water heating, including irrigation handle, exchangeable<br />

jet connection, splash protection, fine-adjustment<br />

n Irrigation mode (adjustable from 36°C to 38°C)<br />

n Stimulation mode, two temperatures are adjustable<br />

(20°C up to 47°C)<br />

n Variable stimulation time (1-99 s)<br />

n Automatic switching with energy-saving mode<br />

Water supply system (REF 530.2040.0)<br />

or water connection system (REF 530.2050.0)<br />

and water drainage system (REF 530.2060.0)<br />

are required<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

REF<br />

530.2030.0<br />

Accessories for ear irrigation / thermal nystagmus stimulation<br />

Ear irrigation bowl<br />

Water collection bowl for connection to the suction<br />

system<br />

Ear irrigation bowl with separate suction channel<br />

For the independent use of the ear irrigation bowl.<br />

Clipboard (REF 530.0010.0) is required.<br />

505.0353.0 *<br />

530.2070.0<br />

Jet connection for water irrigation handle 80 mm 508.0427.0<br />

Jet connection for water irrigation handle 110 mm 508.0429.0<br />

Consumables for ear irrigation/<br />

thermal nystagmus stimulation<br />

Hose tips, 30 pieces<br />

Flexible hose tips, to be slipped on jet connection for<br />

exact guiding of the water jet (30 pcs.)<br />

502.0844.0<br />

Splash protection to be slipped on jet connection 501.0331.0<br />

Hygiene filter for water irrigation system<br />

Independent membrane filter for connection to the<br />

irrigation handle. Medical product acc. to 93/42/EEC,<br />

service life 4 weeks (luer lock).<br />

Accessories for nystagmus stimulation<br />

000.0918.0<br />

Connection for nystagmus binoculars 530.4015.0<br />

Nystagmus binoculars<br />

(Connection for nystagmus binoculars, REF 530.4015.0<br />

is required)<br />

530.4016.0<br />

For technical data regarding the nystagmus stimulation please<br />

see page 59!<br />

33


MedizinTechnik<br />

<br />

<br />

34<br />

Options and accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Compressed air system<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

l Suction equipment<br />

l Ear irrigation / thermal<br />

nystagmus stimulation<br />

l Compressed air<br />

l Light module Economy<br />

l Instrument management<br />

l Supply modules<br />

REF<br />

Medication nebulization with the compressed air system of the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> features by its easy handling:<br />

n One-handed adaptation of the various sprayer bottles to the<br />

compressed air handle.<br />

n The nozzles of the various sprayers are quick and easy to exchange<br />

after every patient.<br />

Optional adjustable compressed air performance enable the comfortable<br />

use of Politzer olives.<br />

Compressed air module<br />

(integrated air compressor, max. 2 bar) for<br />

medication nebulization<br />

including handle, 3 medication bottles with medication<br />

sprayers and support for medication bottles, integrated in<br />

working surface.<br />

Included in delivery:<br />

2 x sprayer straight, complete; 1 x double sprayer, complete<br />

Compressed air module for connection to central<br />

gas supply for medication nebulization<br />

including handle, 3 medication bottles with medication<br />

sprayers (pressure regulator 2 bar integrated in the<br />

module), and support for medication bottles, integrated<br />

in working surface, standard NIST Air connection on the<br />

rear of the device.<br />

Included in delivery:<br />

2 x sprayer straight, complete; 1 x double sprayer, complete.<br />

Connecting hose is not included in delivery!<br />

Options for compressed air module<br />

Fine-adjustment and display for compressed air,<br />

precise pressure reduction for sensitive patients and for use<br />

with Politzer olives. Display on vacuum gauge.<br />

530.3010.0<br />

530.3030.0<br />

530.3040.0


Options and accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Accessories compressed air module<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

REF<br />

Sprayer bottle 000.0577.0<br />

Sprayer, straight 506.5225.0<br />

Sprayer with flexible nozzle (twistable by 360°) 506.5120.0<br />

Sprayer for powdery medications 505.0253.0<br />

Spare nozzle tube with swivel nut for straight sprayer 505.0280.0<br />

Spare nozzle tube for sprayer with flexible nozzle<br />

(twistable by 360°)<br />

Spare hose for sprayer bottle after change of<br />

medication<br />

(10 pcs.)<br />

000.0219.0<br />

506.5229.0<br />

35


MedizinTechnik<br />

36<br />

<br />

<br />

<br />

<br />

Options and accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Light module economy<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

l Suction equipment<br />

l Ear irrigation / thermal<br />

nystagmus stimulation<br />

l Compressed air<br />

l Light module economy<br />

l Instrument management<br />

l Supply modules<br />

REF<br />

The basic module of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> offers<br />

a more simple alternative to the sophisticated optic module<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision. The basic module enables the use of the<br />

innovative LED light source <strong>ATMOS</strong> LS 21 LED and the LED headlight<br />

<strong>ATMOS</strong> HL 21 LED. The ideal solution when scopes are rarely used. At<br />

the same time the advantages of the innovative <strong>ATMOS</strong> LED technology<br />

take effect:<br />

n Damageable light conductors are no longer needed.<br />

n LED light source and headlights have a long LED service life of<br />

approx. 50,000 h. Lamp exchanges are no longer necessary.<br />

n The light intensity is equal to the one of usual halogen cold light<br />

sources with 150 W.<br />

n Optional the mobile use of the LED light source and the LED<br />

headlight is possible for 4 hours by the powerful miniature battery<br />

(optional accessory). Ideal for examinations at the patient’s<br />

bedside!<br />

Light module LED<br />

2 channels, for connection to the LED light source<br />

<strong>ATMOS</strong> HL 21 LED for use with scopes and/or for<br />

the LED headlight <strong>ATMOS</strong> HL 21 LED, module is<br />

switchable, only one channel is activated at a time.<br />

LED headlight <strong>ATMOS</strong> HL 21 LED<br />

n Light source, with long service life and highperformance<br />

white light LED<br />

n Service life 50,000 h<br />

n Infinitely adjustable focusing optic<br />

n Cable 2 m for connection to light module LED<br />

Additional scope of supply:<br />

1 x cable fixation clamp<br />

LED light source <strong>ATMOS</strong> LS 21 LED<br />

for direct connection to scopes and laryngoscopes, with<br />

high-performance white light LED, 2 Watt/50 Lumen,<br />

100 kLux, service life 50,000 h, connection with quick<br />

coupling for any scopes, cable length: 2 m<br />

Included in delivery:<br />

Endoscope adapter Wolf (ACMI → Wolf).<br />

Accessories for light module economy<br />

Lithium-ionic rechargeable battery for mobile use<br />

for <strong>ATMOS</strong> LED light source respectively LED headlight<br />

with power and eco mode, charging indication and<br />

holding clip<br />

Universal battery quick charging power pack<br />

(100-240 V) including multinational adapter<br />

530.4010.0<br />

530.4020.0<br />

507.4600.0<br />

507.4510.0<br />

011.1199.0<br />

Holder for headlight 501.0274.0


Options for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

Instrument management<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Mirror quick heater<br />

Electrically operated heater for quick heating of scopes<br />

and instruments<br />

Heating module for instrument tray<br />

For instrument heating to body temperature, on the<br />

instrument tray (only possible, if the ear irrigation module<br />

37°C basic is not used)<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

REF<br />

530.5010.0<br />

530.5020.0<br />

Instrument tray, melamine, 190 x 150 mm 000.0746.0<br />

Instrument tray, anodised-aluminium, 184x142 mm 508.0058.0<br />

Instrument tray, stainless steel, 180 x 140 mm 508.0058.2<br />

Clipboard<br />

with integrated cotton and tongue patches dispenser<br />

Clipboard<br />

with integrated charging unit for Heine otoscope<br />

(Nicatron)<br />

530.6010.0<br />

530.6020.0<br />

Supply modules (see information for individual options)<br />

Water supply system<br />

Water supply module including water separation<br />

equipment. Protects the drinking water supply network<br />

from contamination caused by the connected medical<br />

devices (fulfils the requirements of EN 1717). For<br />

connection to the drinking water network. Water drainage<br />

module (REF 530.2060.0) is required.<br />

Water connection module<br />

For direct connection to the drinking water network, with<br />

integrated aquastop including connecting hoses (L = 4<br />

m). Water drainage module (REF 530.2060) is required.<br />

Water drainage module<br />

For connection to the local water drainage system,<br />

including lye pump and filling level control of collection<br />

container and drainage hose.<br />

Maximum lifting height: 500 mm<br />

Cable for potential balance<br />

For connection of the module to the potential balance of<br />

the electrical installation.<br />

530.2040.0<br />

530.2050.0<br />

530.2060.0<br />

530.0030.0<br />

According to the rules of the drinking water regulation the operator is obliged to provide a<br />

water supply which is independent from the public drinking water network or to equip it with<br />

a free outlet acc. EN 1717. In the case that such an equipment is not available, <strong>ATMOS</strong> is<br />

able to offer a relevant solution (REF 530.2040.0).<br />

37


MedizinTechnik<br />

Standard colour: ocean<br />

(RAL 5005 signal blue)<br />

1) Further colours for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>:<br />

sapphire (RAL 5003 sapphire)<br />

terra (RAL 2001 red-orange)<br />

coco (RAL 1015 light-ivory)<br />

apple (RAL 6019 white-green)<br />

basic (RAL 7046 grey 2))<br />

turquoise (RAL 5018 turquoise)<br />

Variations of the imaged<br />

colour samples and the<br />

original colour are possible.<br />

Please ask for our<br />

pattern card!<br />

38<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

Basic equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision 230 V<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

l Light modules<br />

l Headlights<br />

l Endoscope management<br />

l <strong>ENT</strong> camera<br />

l Stroboscope<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

Besides the basic equipment images<br />

and specifications also contain optional<br />

functions.<br />

Basic module visualisation unit<br />

531.0000.0<br />

for modular integration of light sources, <strong>ATMOS</strong> camera and LED stroboscopy<br />

systems as well as for enddoscope management.<br />

n Sturdy steel housing, dimensions: H 885 x W 412 x D 540 mm<br />

n Instrument deposit for 2 trays (190 x 150 mm)<br />

(trays are not included in delivery)<br />

or storage for big medication bottles (Ø 10 cm)<br />

n Mobility by 2 castors on the rear side of the device<br />

For modular integration of:<br />

n 5 operation-friendly arranged supports for light conducting cables resp. for<br />

innovative miniature LED light sources, for easy handling of scopes during<br />

examination and disinfection, exchangeable adapters for storing different types of<br />

light conductors<br />

n 4 quivers which can be filled with disinfectant solution, for quick storage of used<br />

scopes<br />

n 4 quivers for storage of unused scopes (optional heated)<br />

n Ergonomic cable and light conductor management<br />

- Light conductors are inside the module and therefore protected against damage<br />

and contamination<br />

- Light sources are readily accessible, especially when changing scopes with<br />

fixed light conductor<br />

n Standard colour: ocean (RAL 5005, signal blue)<br />

n Weight: 15…30 kg, depending on equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision 100 V 531.0001.0<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision 115 V 531.0002.0<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision 127 V 531.0003.0<br />

Further colours for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Select your colour for the housing from 6 different RAL colourings<br />

(see colour samples1) )<br />

Special lacquering<br />

There are more than 200 different colours available (RAL colour samples) for the<br />

housing. Additional price for colours other than standard is:<br />

Structural lacquer (RAL colour samples)<br />

Smooth lacquer (RAL colour samples)<br />

Module door, slotted for feed-in of light conductors<br />

for integration of automatic feed-in of light conductors including fully closed upper<br />

blind.<br />

Automatic feed-in for light conductors / cables<br />

Spring retraction system for automatic retraction of light conductors and cables into<br />

the housing (max. 5 pcs). Option REF 531.0500.0 module door slotted is required.<br />

REF<br />

531.0020.0<br />

531.0021.0<br />

531.0022.0<br />

531.0500.0<br />

531.0300.0


Optional light sources<br />

for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

Licht sources<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

The module <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision can be equipped with max.<br />

4 light sources. All light channels have an automatic switching. The light<br />

conductor or the light source are automatically switched on when they<br />

are removed from the support. The following light sources are available:<br />

n Cold light source, high-performance, halogen 24 V<br />

(service life ca. 300 h)<br />

n Standard cold light source 15 V (service life ca. 50 h)<br />

n Innovative LED light source (service life ca. 50,000 h)<br />

The following light modules are freely combinable (halogen 15 V/24 V<br />

and LED light source). In total there are max. 4 light channels available.<br />

Cold light sources (halogen)<br />

The power supply for cold light systems<br />

(REF 531.1011.0) is required once.<br />

Power supply for cold light equipment<br />

halogen 15 V/24 V<br />

Cold light system halogen 15 V – 1 channel<br />

Light sources (halogen cold light) for use with scopes<br />

with light conducting cable – integrated in the module<br />

<strong>ATMOS</strong> <strong>Servant</strong> S <strong>61</strong> <strong>Servant</strong> vision, lamp service life<br />

approx. 50 h, standard connection: Storz light conductor,<br />

alternatively: Olympus, Wolf, Pentax, see below. The<br />

light source can manually be switched on and off or<br />

is automatically activated when the light conductor is<br />

removed from the support. Adjustable light intensity<br />

between 70-100%, including memory function.<br />

Included in delivery:<br />

1 x Adapter Storz (plastic)<br />

Cold light system high-performance halogen<br />

24 V - 1 channel<br />

Light source (halogen cold light) with high light intensity<br />

for use with scopes with light conducting cable -<br />

integrated in the module <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision.<br />

Long lamp service life (approx. 300 h) due to electronic<br />

softstart. Standard connection: Storz light conductor,<br />

alternatively: Olympus, Wolf, Pentax, see below. The<br />

light source can manually be switched on and off or<br />

is automatically activated when the light conductor is<br />

removed from the support. Adjustable light intensity<br />

between 70-100%, including memory function.<br />

Included in delivery:<br />

1 x Adapter Storz (plastic)<br />

Accessories for halogen cold light sources<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> vision<br />

REF<br />

531.1010.0<br />

531.1020.0<br />

531.1030.0<br />

Adapter sleeve for Storz connection 507.0940.5<br />

Adapter sleeve for Olympus connection 507.0940.6<br />

Adapter sleeve for Pentax connection 507.0940.7<br />

Adapter sleeve for Wolf connection 507.0940.8<br />

39


MedizinTechnik<br />

<br />

<br />

<br />

<br />

40<br />

Optional LED light sources for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

LED light source<br />

LED light source for connection to LED light<br />

handle or LED headlight<br />

Plug connector integrated in the service compartment<br />

of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision. Automatic on/off<br />

switching when the light source is removed. Manual<br />

on/off switching is also possible. Adjustable light<br />

performance 70-100 %.<br />

Accessories for LED light source<br />

LED light handle <strong>ATMOS</strong> LS 21 LED<br />

LED light handle for direct connection to scopes and<br />

laryngoscopes with high-performance white light LED,<br />

2 Watt / 50 Lumen / 100 kLux, service life LED approx.<br />

50,000 h, connection to any desired scope with quick<br />

coupling cable length: 2 m<br />

Additionally included in delivery:<br />

Endoscope adapter Wolf (ACMI → Wolf)<br />

Accessories for LED light handle and LED headlight<br />

Lithium-ionic rechargeable battery for mobile use<br />

For <strong>ATMOS</strong> LED light handle respectively LED headlight<br />

with power and eco mode, charging indication and<br />

holding clip.<br />

Universal battery quick charging power pack (100-240 V)<br />

including multinational adapter.<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

l Light sources<br />

l Headlights<br />

Endoscope management<br />

l <strong>ENT</strong> camera<br />

l Stroboscope<br />

REF<br />

531.1040.0<br />

507.4600.0<br />

507.4510.0<br />

011.1199.0


Headlights for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

Headlights<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Depending on the selected light module the relevant headlight is used:<br />

LED technology: <strong>ATMOS</strong> HL 21 LED<br />

n Damageable light conductors are no longer needed.<br />

n LED light source and headlights have a long LED service life of<br />

approx. 50,000 h. Lamp exchanges are no longer necessary.<br />

n The light intensity is equal to the one of usual halogen cold light<br />

sources with 150 W<br />

n Optional the mobile use of the LED light source and the LED<br />

headlight is possible for 4 hours by the powerful miniature battery<br />

(optional accessory). Ideal for examinations at the patient’s<br />

bedside!<br />

Cold light sources (halogen)<br />

n Headlight with light conducting cable<br />

n Various models, depending on the requested design<br />

(CLAR 73, Binner).<br />

Optional all headlights can be suspended from the automatic switching<br />

headlight hook, which automatically switches on the relevant light<br />

source by removing the headlight. Manual switching is not needed, you<br />

can fully concentrate on your patient.<br />

LED headlight<br />

LED headlight <strong>ATMOS</strong> HL 21 LED<br />

n Light source, with long service life and highperformance<br />

white light LED<br />

n Service life 50,000 h<br />

n Infinitely adjustable focusing optic<br />

n Cable 2 m for connection to LED light source<br />

Additionally included in delivery:<br />

1 x cable fixation clip<br />

Cold light headlight<br />

Headlight CLAR 73, lightweight model<br />

Light conducting cable 2.2 m, 90° connection<br />

Headlight acc. to Binner<br />

Light conducting cable 2.2 m, 90° connection<br />

Options for headlights<br />

Headlight suspension with automatic switching<br />

Hook for the quick removal and storage of the headlight<br />

during patient examination. The light channel (cold light<br />

or LED) is automatically switched on by removing the<br />

headlight.<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> vision<br />

REF<br />

530.4020.0<br />

502.0515.5<br />

502.0516.0<br />

531.1050.0<br />

41


MedizinTechnik<br />

<br />

42<br />

Storz<br />

ACMI<br />

Wolf<br />

(fits to <strong>ATMOS</strong> LS 21 LED)<br />

Optional endoscopes<br />

for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

45°<br />

30°<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Endoscopes<br />

Laryngoscopes<br />

Laryngoscope 70°, without light guide<br />

n working length: 195 mm, Ø 10 mm<br />

Laryngoscope 90°, without light guide<br />

like laryngoscope 70° without light guide<br />

Tele-magnifying laryngoscope 70°,<br />

without light guide<br />

n working length: 195 mm, Ø 10 mm, with handle,<br />

n with integrated focussing and zoom (1.5-fold)<br />

Tele-magnifying laryngoscope 90°,<br />

without light guide<br />

like tele-magnifying laryngoscope 70°<br />

Ear endoscopes, wide-angle Ø 4 mm<br />

Wide-angle optic, 0°<br />

working length: 50 mm, Ø 4 mm, autoclavable<br />

Wide-angle optic, 30°,<br />

working length: 50 mm, Ø 4 mm, autoclavable<br />

Nose / pharynx endoscopes,<br />

wide-angle Ø 4 mm<br />

Wide-angle optic, 0°,<br />

working length: 180 mm, Ø 4 mm, autoclavable<br />

Wide-angle optic, 30°,<br />

working length: 180 mm, Ø 4 mm, autoclavable<br />

Wide-angle optic, 45°,<br />

working length: 180 mm, Ø 4 mm, autoclavable<br />

Wide-angle optic, 70°,<br />

working length: 180 mm, Ø 4 mm, autoclavable<br />

Nose / pharynx endoscopes,<br />

wide-angle Ø 2,7 mm<br />

Wide-angle optic, 0°,<br />

working length: 145 mm, Ø 2,7 mm, autoclavable<br />

Wide-angle optic, 30°,<br />

working length: 145 mm, Ø 2,7 mm, autoclavable<br />

Flexible endoscopes<br />

Naso-pharyngoscope<br />

n Ø 3,4 mm, L = 320 mm, with removable light guide<br />

n direction of view: 0°<br />

n angle of field of view: 80°<br />

n depth of focus: 1 - 50 mm<br />

n angle: 130° / 130°<br />

n light guide cable: Ø 3.5 mm, L =1800 mm<br />

n Storz connection<br />

n With leakage testing device<br />

Delivered in transport case<br />

Light guide for cold light sources<br />

High-performance light guide cable,<br />

Ø 4.8 mm, L = 1800 mm, Storz connection, straight<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

l Light modules<br />

l Headlights<br />

l Endoscope management<br />

l <strong>ENT</strong> camera<br />

l Stroboscope<br />

REF<br />

950.0151.0<br />

950.0177.0<br />

950.0178.0<br />

950.0179.0<br />

950.0156.0<br />

950.0164.0<br />

950.0157.0<br />

950.0158.0<br />

950.0181.0<br />

950.0159.0<br />

950.0160.0<br />

950.01<strong>61</strong>.0<br />

950.0175.0 *<br />

950.0152.0


Endoscope management<br />

for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

<br />

Endoscope management<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

During the examination with scopes you want to concentrate on your<br />

patient. The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision offers the perfect solution for<br />

endoscope handling:<br />

If required, clean endoscopes can be stored in a heated quiver. When<br />

removing from the quiver the relevant light source is switched on<br />

automatically. After examination the scope can be deposited in a second<br />

quiver which can be filled with disinfectant solution. In case you would<br />

like to store the scope in the disinfectant solution for a defined period of<br />

time, a LED indication showing the desired disinfection time is optionally<br />

available. At a maximum 4 of the following endoscope management<br />

systems can be combined.<br />

One-channel endoscope management for rigid scopes<br />

For the safe and quick storage of scopes<br />

(max. L = 190 mm), consisting of:<br />

n 1 metal quiver (Ø 18 mm) for storage of clean scopes<br />

(optionally heated), filling with disinfectant solution is<br />

possible<br />

n 1 plastic quiver (Ø 35 mm) for storage of scopes<br />

(suitable for filling with disinfectant solution)<br />

One-channel endoscope management<br />

for flexible scopes<br />

Max. length 500 mm, consisting of:<br />

Optic sleeve, protecting tube and optic sleeve Pentax<br />

Endoscope heating<br />

To prevent endoscopes from fogging during the<br />

examination they are heated to body temperature<br />

in metal quivers. Module heats all channels of the<br />

endoscope management.<br />

Disinfection time monitoring<br />

After storage of the scope in the quiver, an electronic<br />

stop watch function can be activated at one key press<br />

for the requested disinfection period. The stop watch<br />

shows the duration of disinfection by means of a LED.<br />

Accessories for endoscope management<br />

Protective sleeve<br />

For endoscopes Ø 2.8 – 4 mm, teflon element<br />

for metal quiver<br />

Fixation adapter for plastic quiver<br />

for safe storage of used endoscopes<br />

Ø 2,8-4 mm in the plastic quiver<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> vision<br />

REF<br />

531.1060.0<br />

531.1070.0<br />

531.1080.0<br />

531.1090.0<br />

508.0777.5<br />

508.0782.0<br />

43


MedizinTechnik<br />

<br />

<br />

44<br />

Optional<br />

integrated <strong>ENT</strong> cameras<br />

for <strong>ATMOS</strong> S <strong>61</strong> vision<br />

<strong>ATMOS</strong> <strong>ENT</strong> cameras<br />

The <strong>ATMOS</strong> <strong>ENT</strong> cameras feature their suitability for the daily use in<br />

practice:<br />

n High image quality<br />

n Easy, one-handed exchange of scopes<br />

n One-handed focussing, even during examination<br />

n Easy to operate (no white balancing)<br />

Automatic mode<br />

By removing an endoscope from the support and the activation of the<br />

light channel, the camera is automatically adjusted to the previously<br />

used settings. With it camera adjustments are unnecessary – the<br />

complete visualisation system is perfectly preset and ready to operate. It<br />

cannot be easier!<br />

Optional equipment:<br />

n Integrated image memory with foot switch for freezing up to 4 images:<br />

<strong>ATMOS</strong> Cam 31 and <strong>ATMOS</strong> Cam 31 DV<br />

n Digital interface, perfect image quality for archiving on computer and<br />

laptop: <strong>ATMOS</strong> Cam 21 DV and <strong>ATMOS</strong> Cam 31 DV<br />

Digital<br />

interface<br />

IEEE 1394<br />

Integrated<br />

image<br />

memory<br />

<strong>ATMOS</strong> Cam 21 <strong>ATMOS</strong> Cam 21 DV <strong>ATMOS</strong> Cam 31 <strong>ATMOS</strong> Cam 31 DV<br />

- - <br />

- - <br />

When the <strong>ATMOS</strong> Strobo 21 LED and a camera module are<br />

requested an additional permanent power supply (REF 531.0030.0)<br />

is required.<br />

<strong>ATMOS</strong> Cam 21 without image memory<br />

High-resolving 1/3“ CCD camera with high light sensitivity<br />

for endoscopy, microscopy and video stroboscopy;<br />

camera head with integrated video adapter and digital<br />

zoom up to factor 1.7; cable length camera head-control<br />

unit: 2 m; <strong>ENT</strong>-optimized application adjustment due to<br />

selection of 4 light sources as well as 4 application parts;<br />

automatic white balancing and manual white balancing<br />

with storage; weight of control unit: 2.35 kg; camera<br />

head incl. cable: 235 g; incl. video cable and support for<br />

camera head<br />

<strong>ATMOS</strong> Cam 21 DV without image memory<br />

Like <strong>ATMOS</strong> Cam 21, but<br />

with DV interface for digital image transmission, including<br />

connecting cable for computer and laptop<br />

Additionally included in delivery: jack plug S+B, 3/5 cinch<br />

<strong>ATMOS</strong> Cam 31 with image storage via foot switch<br />

Like <strong>ATMOS</strong> Cam 21, but with digital zoom up to factor<br />

2.0, image memory (1- resp. 4-image mode)<br />

<strong>ATMOS</strong> Cam 31 DV with image storage via foot switch<br />

Like <strong>ATMOS</strong> Cam 21, but<br />

with digital zoom up to factor 2.0, image memory<br />

(1- resp. 4-image mode), with DV interface for digital<br />

image transmission, including connecting cable for<br />

computer and laptop<br />

Included in delivery: jack plug S+B, 3/5 cinch.<br />

For technical data please see page 162!<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

l Light modules<br />

l Head lights<br />

l Endoscope management<br />

l <strong>ENT</strong> cameras<br />

l Stroboscopy<br />

REF<br />

531.2010.0<br />

531.2020.0<br />

531.2030.0<br />

531.2040.0


LED Stroboscopy<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

LED stroboscopy<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Modern LED technology enables the stroboscopic examination<br />

at the treatment unit to be performed as easy as the endoscopic<br />

larynxdiagnostics. High-performance white light LED and a sophisticated<br />

microphone electronics quickly provide an image of the mucosal wave.<br />

The <strong>ATMOS</strong> Strobo 21 LED can be integrated into the operation panel<br />

of the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision.<br />

LED stroboscope<br />

<strong>ATMOS</strong> Strobo 21 LED<br />

Noiseless stroboscopy with flash light and pilot light<br />

for vocal cord diagnostics based on LED technology.<br />

Including attachable LED light handle for direct<br />

connection to existing laryngoscopes. Freeze image<br />

with variable phasing and slow motion mode, adjustable<br />

with foot switch. Display of voice frequency and sound<br />

pressure level, audio output for archiving the voice signal<br />

(including attachable laryngoscope microphone),<br />

flash frequency 70 - 1000 Hz without reduction.<br />

Included in delivery:<br />

1 x audio cable, cinch-cinch mono; 1 x foot controller for <strong>ATMOS</strong><br />

Strobo 21 LED; 1 x microphone for <strong>ATMOS</strong> Strobo 21 LED; 1 x<br />

dongle plug for interlink<br />

For technical data please see page 152!<br />

Permanent power supply<br />

is required when the <strong>ATMOS</strong> Strobo 21 LED and a<br />

camera module are requested.<br />

Accessories for LED stroboscope<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> vision<br />

REF<br />

531.2050.0<br />

531.0030.0<br />

Body sound microphone adapter 507.4775.0<br />

45


MedizinTechnik<br />

Standard colour: ocean<br />

(RAL 5005 signal blue)<br />

1) Further colours for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>:<br />

sapphire (RAL 5003 sapphire)<br />

terra (RAL 2001 red-orange)<br />

coco (RAL 1015 light-ivory)<br />

apple (RAL 6019 white-green)<br />

basic (RAL 7046 grey)<br />

turquoise (RAL 5018 turquoise)<br />

46<br />

Besides the basic equipment images<br />

and specifications also contain optional<br />

functions.<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Basic equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Basic <strong>ENT</strong> instrument cabinet for modular integration of waste bin, bowl for used<br />

instruments, drawers, writing surface, placement area for instrument trays in<br />

up to 3 levels.<br />

n Sturdy steel housing, dimensions: H 885 x W 412 x D 540 mm<br />

n Roller-shutter cover<br />

n Instrument deposit on the lower level<br />

(4 trays 190 x 150 mm or 2 trays 300 x 190 mm)<br />

(trays are not included in delivery)<br />

n Instrument deposit on the upper level (2 trays 190 x 150 mm)<br />

n Shallow drawer<br />

n Mobility by 2 castors on the rear side of the device<br />

n Standard colour: ocean (RAL 5005, signal blue)<br />

n Weight: 17 kg<br />

Further colours for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Please select your colour for the housing from 6 different RAL colourings<br />

(see colour samples 1) )<br />

Special lacquering<br />

There are more than 200 different colours available (RAL colour samples).<br />

Additional price for colours other than standard.<br />

Structural lacquer (RAL colour samples)<br />

Smooth lacquer (RAL colour samples)<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

l Waste bin<br />

l Instrument deposit<br />

l Drawers<br />

l Instrument management<br />

l Supply modules<br />

Position for modules:<br />

top<br />

middle<br />

bottom<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

REF<br />

532.0000.0<br />

532.0020.0<br />

532.0021.0<br />

532.0022.0<br />

Lock for roller-shutter cover 532.1010.0<br />

Central locking system for drawers 532.2015.0<br />

Variations of the imaged colour samples and the original colour are possible. Please ask for our pattern card!


top<br />

<br />

middle<br />

bottom<br />

Options for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Possible drawer combinations: (See next page!)<br />

<br />

1 Instrument deposit<br />

1 Waste bin<br />

1 Retractable writing surface<br />

Waste bin<br />

<br />

<br />

<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Drawer with integrated support for plastic disposable bag<br />

for waste collection. For hygienic reasons, the waste bin<br />

is easy to open and to close by a tap with the foot to the<br />

drawer. Position: bottom (2 elements high)<br />

Included in delivery: 1 x disposable bags (50 pcs.)<br />

Deposit for used instruments<br />

Drawer for easy deposit of used instruments. With closed<br />

drawer they can be deposited in the integrated plastic<br />

container (bowl for used instruments). If requested, the<br />

bowl can be filled with disinfectant solution. For the safe<br />

exchange of the bowl, the drawer can be opened.<br />

n Drawer<br />

n Bowl for used instruments, including cover<br />

Position: in the middle/on the top<br />

Included in delivery: 1 x bowl for used instruments; 1 x cover for<br />

instrument bowl<br />

1 Drawer<br />

1 Waste bin<br />

1 Retractable writing surface<br />

<br />

<br />

<br />

2 Instrument deposits<br />

1 Drawer<br />

1 Retractable writing surface<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> instruments<br />

REF<br />

532.1020.0<br />

532.1030.0<br />

Deposit for used instruments airmatic 532.1050.0<br />

Deposit for used instruments (wet storage)<br />

As described above, but all parts which may become<br />

splashed are available in stainless steel to prevent<br />

from corrosion, which might be caused by aggressive<br />

disinfectant solutions<br />

Included in delivery: 1 x bowl for used instruments; 1 x cover for<br />

instrument bowl<br />

532.1040.0<br />

Deposit for used instruments (wet storage) airmatic 532.1070.0<br />

Spare bowl for used instruments<br />

Enables a smooth workflow at the treatment unit during<br />

instrument cleaning/disinfection<br />

506.7751.0<br />

Cover for instrument bowl 506.7752.0<br />

Stainless steel sieve for instrument deposit 506.7759.0<br />

47<br />

<br />

<br />

<br />

3 Drawers<br />

1 Retractable writing surface


MedizinTechnik<br />

<br />

<br />

<br />

48<br />

Options for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Drawers<br />

Drawer instruments<br />

Position: at the top, in the middle, at the bottom<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

l Waste bin<br />

l Bowl for used instruments<br />

l Drawers<br />

l Instrument management<br />

l Supply modules<br />

REF<br />

532.2010.0<br />

Drawer (two elements high) 532.2011.0<br />

Drawer (two elements high) airmatic 532.1060.0<br />

Drawer Airmatic instruments 532.2020.0<br />

Drawer airmatic instruments heated, (230 V),<br />

supply module for power supply <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

instruments is required<br />

(REF 532.0110.0, see below)<br />

Drawer airmatic instruments heated, (100-127 V)<br />

supply module for power supply <strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> instruments is required<br />

(REF 532.0111.0, see below)<br />

Retractable writing surface (stainless steel)<br />

Instrument management<br />

Mirror pre-heater 230 V<br />

Heated mirror holder for approx. 50 mirrors (mirror size<br />

max. Ø 26 mm). Mirrors are heated to prevent from<br />

fogging. Supply module for power supply is required<br />

(REF 532.0110.0)<br />

Mirror pre-heater (100-127 V)<br />

Heated mirror holder for approx. 50 mirrors (mirror size<br />

max. Ø 26 mm). Mirrors are heated to prevent from<br />

fogging. Supply module for power supply is required<br />

(REF 532.0110.0).<br />

Instrument deposit in the medium level<br />

Additional module for instrument deposit in an additional<br />

level for 2 trays 190 x 150 mm<br />

Supply modules <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Power supply for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

(230 V)<br />

Power supply for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

(100-127 V)<br />

532.2030.0<br />

532.2031.0<br />

532.2040.0<br />

532.2050.0<br />

532.2051.0<br />

532.2060.0<br />

532.0110.0<br />

532.0111.0


Options for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Tray, narrow<br />

Instrument management<br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> instruments and <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

therapy offer the following placement areas for instrument trays:<br />

a) On the top/behind roller-shutter cover:<br />

n 2 instrument tray, small (different materials)<br />

b) First level below roller-shutter cover<br />

n 4 instrument trays, small + 1 tray, narrow (stainless steel) for ear funnels<br />

or<br />

n 2 instrument trays, large + 1 tray, narrow (stainless steel) for ear funnels<br />

c) Medium instrument level (optional)<br />

n 2 instrument trays, small<br />

Optional instrument management REF<br />

Instrument tray, melamine, small, 190 x 150 mm 000.0746.0<br />

Instrument tray, melamine, large, 300 x 190 mm 000.0747.0<br />

Instrument tray, anodised aluminium,<br />

small, 184 x 142 mm<br />

Instrument tray, anodised aluminium,<br />

large, 284 x 184 mm<br />

E N T<br />

508.0058.0<br />

505.0516.0<br />

Instrument tray, stainless steel, small 180 x 140 mm 508.0058.2<br />

Instrument tray, stainless steel, large 280 x 180 mm 505.0516.2<br />

Serrated instrument holder, large 508.0566.0<br />

Serrated instrument holder, small 508.0567.0<br />

Instrument intermediate deposit<br />

with paper, in aluminium or stainless steel tray<br />

Holder for ear specula / Politzer olives<br />

(in a small tray)<br />

Tray, narrow for instrument deposit module<br />

for use with melamine trays<br />

für use with aluminium/stainless steel<br />

Tray, narrow, (stainless steel) for use with melamine<br />

instrument trays, 381 x 31 mm<br />

Tray, narrow, (stainless steel) for use with aluminium/<br />

stainless steel instrument trays, 381 x 46 mm<br />

508.0533.0<br />

508.0545.0<br />

534.0145.0<br />

534.0146.0<br />

532.0145.0<br />

532.0146.0<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> instruments<br />

49


MedizinTechnik<br />

Standard colour ocean<br />

(RAL 5005 signal blue)<br />

1) Further colours for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>:<br />

saphhire (RAL 5003 sapphire)<br />

terra (RAL 2001 red-orange)<br />

coco (RAL 1015 light ivory)<br />

apple (RAL 6019 white-green)<br />

basic (RAL 7046 grey 2)<br />

turquoise (RAL 5018 turquoise)<br />

50<br />

Besides the basic equipment images<br />

and specifications also contain optional<br />

functions.<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Basic equipment<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Basic <strong>ENT</strong> instrument cabinet for modular integration of RF surgical devices,<br />

drawers, writing surface, placement area for instrument trays<br />

in up to 3 levels. Optional with roller-shutter cover.<br />

n Sturdy steel housing, dimensions: H 885 x W 412 x D 540 mm<br />

n Roller-shutter cover<br />

n Instrument deposit on the lower level<br />

(4 trays 190 x 150 mm or 2 trays 300 x 190 mm) (trays are not included in delivery)<br />

n Instrument deposit on the upper level (2 trays 190 x 150 mm)<br />

n Shallow drawer in the upper part<br />

n Mobility by 2 castors on the rear side of the device<br />

n Standard colour: Ocean (RAL 5005, signal blue)<br />

n Weight: 15…32 kg, depending on equipment<br />

Further colours for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Select your colour for the housing from 6 different RAL colourings<br />

(see colour samples 1) )<br />

Special lacquering<br />

There are more than 200 different colours available (RAL colour samples).<br />

Additional price for colours other than standard.<br />

Structural lacquer (RAL colour samples)<br />

Smooth lacquer (RAL colour samples)<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

l Writing surface<br />

l <strong>ATMOS</strong> RF surgical devices<br />

Position for modules:<br />

top<br />

middle<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

REF<br />

533.0000.0<br />

533.0020.0<br />

533.0021.0<br />

533.0022.0<br />

Lock for roller-shutter cover 532.1010.0<br />

Retractable writing surface 532.2040.0<br />

Central locking system for drawers 532.2015.0<br />

Variations of the imaged colour samples and the original colour are possible. Please ask for our pattern card!


Radio frequency surgery in the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Radio frequency surgical device <strong>ATMOS</strong> RS 221 <strong>ENT</strong><br />

With the new <strong>ATMOS</strong> radiofrequency therapy for <strong>ENT</strong> applications a new<br />

generation of electrosurgical devices is now available for<br />

<strong>ENT</strong> medicine. Especially for the following fields of application<br />

radiofrequency surgery is advantageous:<br />

n Immediate haemostasis by coagulation.<br />

n Very slight tissue damage of the surrounding tissue in the field of tonsil<br />

surgery.<br />

n Minimal bleeding<br />

n Less lateral heating guarantees less tissue necrosis and minimized<br />

scarring.<br />

n Opening incision through the cuticle is possible.<br />

Furthermore the bipolar tissue induration has approved in snore therapy.<br />

With this appliance for radiofrequency therapy, the expense factor is much<br />

lesser than the cost price of complete laser equipment.<br />

Drawer for HF / RF surgical device<br />

Drawer for integration of the RF surgical device <strong>ATMOS</strong><br />

RS 221 <strong>ENT</strong> for the use directly at the treatment unit.<br />

n Placement area for electrode cables and electrodes in<br />

the drawer<br />

n User-friendly positioning of the operation panel and all<br />

plug connections<br />

n Also suitable for similar devices<br />

Position: at the top<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong> Radiosurgical System 2.2 MHz<br />

4 operating mode: cutting, coagulation-cutting,<br />

monopolar coagulation, bipolare coagulation, automatic<br />

switching of the outlets: cutting/coagulation alternatively<br />

with handpiece or foot switch. Memory function for<br />

storing the last used values. Cutting performance max.<br />

100 W. Coagulation performance max. 90 W. Standard<br />

connections for <strong>ATMOS</strong>, Martin, Berchtold devices, incl.<br />

<strong>ENT</strong> set of electrodes (<strong>ENT</strong> needle electrode 32, <strong>ENT</strong><br />

round loop electrode 35, <strong>ENT</strong> ball-shaped electrode 34,<br />

<strong>ENT</strong> tonsil electrode, <strong>ENT</strong> radioconchotherapy electrode,<br />

<strong>ENT</strong> UPP electrode), mains cable 3 m and operating<br />

instructions; 230 V / 50 Hz.<br />

Technical data of the <strong>ATMOS</strong> RS 221 you will find on page 62!<br />

<strong>ATMOS</strong> RS 221 monopolar accessories set<br />

n tool holder, Cutting (for 1.6 mm electrodes)<br />

n tool holder, Coagulation (for 1.6 mm electrodes)<br />

n standard set of electrodes (41, 43, 44, 45, 46, 47, 48)<br />

n neutral electrode with rubber fixation<br />

n connection cable for neutral electrode<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong> bipolar accessories set<br />

n bipolar tweezers, short, straight, L = 110 mm<br />

n foot switch with 2.5 m cable<br />

n bipolar cable, L = 2.5 m<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong> accessories (monopolar)<br />

n tool holder, cutting (for 1.6 mm electrodes)<br />

n tool holder, coagulating (for 1.6 mm electrodes)<br />

n <strong>ENT</strong> set of electrodes (32, 35, 34, <strong>ENT</strong> tonsil<br />

electrode, <strong>ENT</strong> radioconchotherapy electrode,<br />

<strong>ENT</strong> UPP electrode<br />

n neutral electrode with rubber bandage<br />

n connecting cable for neutral electrodes<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> therapy<br />

REF<br />

533.1010.0<br />

506.5900.0<br />

506.5850.0<br />

506.5860.0<br />

506.5880.0<br />

51


MedizinTechnik<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

52<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Accessories for <strong>ATMOS</strong> RS 221<br />

<strong>ENT</strong> applications<br />

Accessories for <strong>ATMOS</strong> RS 221 <strong>ENT</strong> radiosurgery<br />

Tool holder yellow<br />

cutting (for 1.6 mm electrodes), cable length 2.5 m<br />

Tool holder blue<br />

coagulating (for 1.6 mm electrodes), cable length 2.5 m<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

l <strong>ATMOS</strong> RS 221 <strong>ENT</strong><br />

- Accessories<br />

- Consumables<br />

REF<br />

506.5851.0<br />

506.5852.0<br />

Neutral electrode 506.5853.0<br />

Connecting cable for neutral electrode 506.5854.0<br />

Rubber bandage for neutral electrode 0.5 m 506.5855.0<br />

Foot switch with 2.5 m cable 506.58<strong>61</strong>.0<br />

Bipolar cable L = 2.5 m 506.5862.0<br />

Bipolar tweezers<br />

short, straight, L = 110 mm, tip 0.5 mm<br />

Bipolar electrode<br />

L = 180 mm, long bent autoclavable<br />

electrode distance 2 mm, Ø 0.3 mm<br />

506.5863.0<br />

506.5864.0 *


<strong>ATMOS</strong> <strong>ENT</strong> electrodes<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy –<br />

electrodes for<br />

<strong>ENT</strong> radiosurgical system<br />

<strong>ATMOS</strong> RS 221 <strong>ENT</strong><br />

Consumables for <strong>ATMOS</strong> RS 221 <strong>ENT</strong><br />

# 45<br />

# 47<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

# 48<br />

# 44<br />

# 43<br />

# 46<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> therapy<br />

REF<br />

Self-adhesive disposable electrodes (50 pcs.) 506.5878.0<br />

Cable for self-adhesive disposable electrodes 506.5877.0<br />

<strong>ENT</strong> needle electrode flexible (Cutting) #32<br />

L = 100 mm, super-fine wire, yellow shaft (2 pcs.)<br />

<strong>ENT</strong> loop electrode flexible (Cutting) #35<br />

L = 128 mm, Ø loop 9 mm, super-fine wire, yellow shaft,<br />

(2 pcs.)<br />

<strong>ENT</strong> ball-shaped electrode (Coag) #34<br />

L = 100 mm, Ø ball 9 mm, blue shaft (2 pcs.)<br />

<strong>ENT</strong> tonsil electrode (glossa-tonsil-coag)<br />

L = 105 mm, tip needle 18 mm, (12 mm isolated), blue shaft<br />

<strong>ENT</strong> radioconchotherapy electrode (Coag)<br />

soft palate, L = 155 mm, tip needle 26 mm, (10 mm isolated)<br />

506.5881.0<br />

506.5882.0<br />

506.5883.0<br />

506.5884.0<br />

506.5885.0<br />

<strong>ENT</strong> UPP Electrode (uvulopalatoplasty, cutting) 506.5886.0<br />

Multi-tip Electrode #41, with spare wire (2 pcs.)<br />

with adjustable wire for depth control, yellow shaft, wire 0.2 mm<br />

506.5870.0<br />

Round loop electrode #43 (2 pcs.) Ø 13 mm. 506.5871.0<br />

Round loop electrode # 44 (2 pcs.) Ø 7 mm. 506.5872.0<br />

Rhomibal electrode # 45 (2 pcs.) leg length 7 mm 506.5873.0<br />

Triangle electrode # 46 (2 pcs.) leg length 7 mm 506.5874.0<br />

Thick needle-coagulation-electrode #47 (2 pcs.)<br />

needle Ø = 1.5 mm, needle length 1.5 mm.<br />

506.5875.0<br />

# 41<br />

53


MedizinTechnik<br />

<br />

<br />

<br />

<br />

54<br />

<br />

Optional<br />

smoke evacuation system for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

Smoke evacuation system <strong>ATMOS</strong> SE 6501<br />

The use of electrosurgical devices is linked with the<br />

following problems:<br />

n Health risk due to toxic gases, harmful aerosols, and<br />

human viruses.<br />

n An obscured view in the operating field associated with<br />

unpleasant smells.<br />

The smoke evacuation system <strong>ATMOS</strong> SE 6501 is the<br />

perfect supplement to the <strong>ATMOS</strong> RS 221 <strong>ENT</strong>.<br />

Compartment for smoke evacuation system<br />

For integration of the smoke evacuation system<br />

<strong>ATMOS</strong> SE 6501; position: below<br />

Smoke Evacuation Module <strong>ATMOS</strong> SE 6501<br />

Microprocessor-controlled unit for removing and filtering<br />

surgical smoke, with automatic switch off, filter control<br />

and electronically controlled brushless blower (incl. ULPA<br />

main filter and 3-stages gas filter), hose and prefilter set,<br />

mains cable, pump performance up to 600 l/min, incl.<br />

holder for suction hose on the function support,<br />

Position: below, 2 elements high (230 V / 50 Hz).<br />

For technical data please see page 62!<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

l <strong>ATMOS</strong> SE 6501<br />

- Consumables<br />

- FAQ<br />

REF<br />

533.1020.0<br />

533.1025.0<br />

Consumables for <strong>ATMOS</strong> SE 6501 (smoke evacuation system)<br />

Main filter with electronically controlled service life<br />

(ULPA 99,9999%@0,01µm / 3-steps gas filter)<br />

Change: after approx. 150 patients<br />

Pre-filter (HEPA)<br />

with connections Ø 22 mm (M/W), (male/female), sterile,<br />

not autoclavable, 50 pcs., to be used for laser ablations<br />

Change: 1 x per patient<br />

Air hose,<br />

Internal Ø =10 mm, L = 1,8 m autoclavable at 132 °C,<br />

made of hytrel, connecting sockets made of silicone<br />

Change: after 50 x autoclaving<br />

Air suction handle for monopolar Slim-Line<br />

surgery handles, clip-on handle, air hose Ø 10 mm,<br />

L = 2,5 m, 25 pcs.,<br />

Change: 1 x per patient<br />

Hose connector,<br />

straight, Ø 22 mm (male) to Ø 10 mm (male)<br />

autoclavable up to 134°C,<br />

Change: after 50 x autoclaving<br />

Hose connector, straight,<br />

Ø 22 mm (female) to Ø 10 mm (male)<br />

autoclavable up to 134°C<br />

Change: after 50 x autoclaving<br />

445.0040.0<br />

445.0044.0<br />

005.0204.0<br />

445.0063.0 *<br />

000.0689.0<br />

000.0688.0


Frequently asked<br />

questions on the smoke<br />

evacuation problem<br />

1. Is normal operating theatre ventilation adequate for<br />

evacuating smoke?<br />

No, the rate of air circulation in the room - up to<br />

24 x volume/hour - is not sufficient to evacuate locally<br />

generated aerosols and gases; the user is still exposed to<br />

dangerous laser smoke.<br />

2. So a normal room suction system (a central vacuum)<br />

is not good enough?<br />

No, the rate of room suction in an operating theatre is too<br />

low, at 30-40 l/min. Research has shown that a minimum<br />

of 400-600 l/min. is required in the operating field.<br />

3. How great is the risk of becoming infected from<br />

biological substances during an operation?<br />

Research is currently being undertaken to ascertain the<br />

degree of danger that exists from using different lasers<br />

and electrosurgical instruments. It has been proven that<br />

infectious particles can reach theatre staff and thereby<br />

create an acute risk of infection via the mucous<br />

membranes and respiratory tracts.<br />

4. So are the particles generated during an operation<br />

really dangerous?<br />

Airborne viruses such as papilloma viruses, proteins such<br />

as prions (BSE pathogens) and other airborne bacteria<br />

and funghi are dangerous substances that can lead to<br />

direct infection.<br />

5. Do surgical face masks help protect the operating<br />

staff?<br />

No, surgical face masks offer theatre staff no protection<br />

against airborne particles. These masks were designed<br />

to protect patients from droplet infections emanating<br />

from the operating team.<br />

Up to 25 % of air breathed in gets past the mask.<br />

6. Are there other reasons for carrying out localised<br />

smoke evacuation, apart from the risk of infection?<br />

The use of local smoke evacuation, when carried out<br />

during endoscopies, minimally invasive surgery and<br />

partially open and closed body cavities, gives optimum<br />

visibility.<br />

Extracted by:<br />

„Smoke-by products<br />

in the laser and HF surgery“<br />

An information brochure for<br />

staff and patients<br />

Edited by <strong>ATMOS</strong> MedizinTechnik<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

7. How do doctors react to smoke evacuation devices?<br />

Smoke evacuation enjoys a high level of acceptance<br />

among medics, as they no longer have to contend with<br />

an obscured view of the surgical site.<br />

8. What effects do particles and gases have on<br />

the patient?<br />

During laparoscopies in particular, toxic gases diffuse into<br />

the patient‘s bloodstream. Small airborne particles in this<br />

smoke (measuring from 0.1 to 0.5 µm) cause ocular<br />

and upper respiratory tract irritation.<br />

9. Is there a risk to the patient?<br />

Medical staff should be aware of the risks to the patient<br />

from laser use and diathermic smoke generation during<br />

an operation. Some of the smoke inside a closed<br />

abdominal cavity can lead to an increase in<br />

methaemoglobin content, which reduces the capacity of<br />

body tissue to absorb oxygen.<br />

10. Does the suction device have to be operated<br />

separately?<br />

No, the suction device runs in the background; assistant<br />

theatre staff do not need to devote any resources to<br />

operating it. The smoke evacuation unit is activated<br />

automatically when needed.<br />

11. How high are the running costs of local smoke<br />

evacuation?<br />

The operating costs of the filter system are less than<br />

1 Euro per surgical procedure and the filter unit has a<br />

life of up to 52 hours, depending on flow.<br />

12. Do lasers deactivate dangerous airborne viruses?<br />

No, research on retroviruses has shown that infectious<br />

viruses and constituents of virus DNA are carried in laser<br />

smoke. So it is possible to be infected, for example,<br />

by papilloma viruses in the laser smoke.<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> therapy<br />

55


MedizinTechnik<br />

56<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

Basic equipment<br />

System frame<br />

<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

l Microscopes and accessories<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

Besides the basic equipment images<br />

and specifications also contain<br />

optional functions.<br />

The <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system offers the appropriate frame for sophisticated treatment units.<br />

Here the particular <strong>ATMOS</strong> S <strong>61</strong> modules are safely placed and protected against slipping and<br />

vibrations. Up from 3 modules the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system enables the vibration-free<br />

integration of a microscope at the treatment unit <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong>.<br />

Furthermore this system frame offers the possibility to integrate further instrument placement<br />

areas and deposits.<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

for 2 modules (without microscope column)<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

for 3 modules (without microscope column)<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

for 4 modules (without microscope column)<br />

REF<br />

534.1005.0<br />

534.1010.0<br />

534.1020.0


<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

Microscopes<br />

Microscopes<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

There are two microscope types available, which can be integrated into<br />

the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system:<br />

n OPMI pico<br />

n <strong>ATMOS</strong> Mikro 02<br />

The optional automatic switching activates the microscope illumination<br />

automatically when the microscope is used.<br />

The magnification changer offers various magnifications for the perfect<br />

adaptation of the image to the examination surrounding.<br />

A beam splitter can be integrated directly in front of the ocular enabling<br />

the connection of an <strong>ATMOS</strong> <strong>ENT</strong> camera. With it, all microscopic<br />

examinations can be visualised. In addition, if requested, the<br />

examination results can be archived with the documentation system<br />

<strong>ATMOS</strong> MedDoc on the computer.<br />

Examination microscope OPMI pico with<br />

automatic on/off switching<br />

objective f = 250 mm, wide-angle straight tube<br />

f = 170 mm, 2 spectacle-wearer oculars with<br />

10 x magnification, incl. 5-steps magnification changer<br />

(0,4 x - 2,5 x), T-handle, dust cover, light conductor<br />

(<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system is required).<br />

E N T<br />

<strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> system<br />

REF<br />

534.2010.0 *<br />

OPMI pico floor stand 508.1660.0 *<br />

OPMI pico wall bracket 508.1665.0 *<br />

Beam splitter for microscopes<br />

(<strong>ATMOS</strong> and OPMI pico)<br />

with integrated camera connection<br />

<strong>ENT</strong> examination microscope <strong>ATMOS</strong> Mikro 02<br />

with automatic on/off switiching<br />

Objective f = 200 mm, wide-angle straight tube f =<br />

125 mm, 2 wide-angle oculars with 10 x magnification,<br />

handle, light conductor,<br />

(<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system is required).<br />

508.1633.0 *<br />

534.2030.0<br />

<strong>ATMOS</strong> Mikro 02 floor stand 508.1670.0<br />

<strong>ATMOS</strong> Mikro 02 wall bracket 508.1675.0<br />

Accessories for microscope <strong>ATMOS</strong> Mikro 02<br />

Magnification changer,<br />

3-steps for <strong>ENT</strong> examination microscope<br />

<strong>ATMOS</strong> Mikro 02 (only in connection with the<br />

microscope, not for retrofitting!)<br />

Cold light module for microscope<br />

150 W cold light module for mounting to the system<br />

frame<br />

508.1641.0<br />

534.2040.0<br />

57


MedizinTechnik<br />

<br />

<br />

<br />

<br />

58<br />

Accessories for<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

Monitor<br />

TFT-Monitor<br />

17“ TFT video monitor with medical power pack, and with<br />

video and computer connections.<br />

Monitor arm <strong>ATMOS</strong> S <strong>61</strong> <strong>ENT</strong> professional<br />

A monitor, mounted on a swivel arm, can be integrated<br />

in the working area, it enables ergonomic working. It is<br />

possible to position the monitor<br />

a) beside the patient chair during examination<br />

b) in front of the microscope column<br />

for demonstration purposes<br />

Module for instrument deposit<br />

Module for instrument deposit (40 cm broad)<br />

This module offers the possibility to considerably enlarge<br />

the space for instrument storage. There is space for<br />

4 small or 2 large trays on 2 levels and an additional<br />

narrow tray (REF 534.0145.0 resp. REF 534.0146.0)<br />

depending on the material of the instrument trays used.<br />

(Trays are not included in delivery!)<br />

In order to protect the instruments from contamination<br />

the standard module is equipped with a roller-shutter<br />

cover (optional available as lockable version).<br />

Tray narrow for instrument deposit module<br />

for use with melamine trays<br />

for use with aluminiun / stainless steel trays<br />

For further instrument trays please see page 49.<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

l Monitor<br />

l Module for instrument deposit<br />

l Technical Data<br />

REF<br />

534.3010.0 *<br />

534.3020.0<br />

534.3040.0<br />

534.0145.0<br />

534.0146.0<br />

Lock for roller-shutter cover 532.1010.0<br />

Shelf (glass) 40 cm broad 534.3050.0<br />

Shelf (metal) 40 cm broad 534.3060.0<br />

Shelf adapter<br />

for direct mounting of shelves, modules for instrument<br />

deposit resp. monitor support to the <strong>ATMOS</strong> S <strong>61</strong><br />

<strong>Servant</strong> (without system frame).<br />

Monitor arm for shelf adapter<br />

for direct mounting to the <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

Illumination<br />

Illumination module (white-light LED)<br />

for mounting underneath the module for instrument<br />

deposit, REF 534.3040.0 resp. shelf, REF 534.3060.0<br />

Illumination module (blue-light LED)<br />

for mounting underneath the module for instrument<br />

deposit, REF 534.3040.0 resp. shelf, REF 534.3060.0<br />

Rear walls for system frame<br />

Rear wall for <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> system<br />

for 2 modules<br />

for 3 modules<br />

for 4 modules<br />

Working surface for mounting to the<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

534.3090.0<br />

534.3095.0<br />

534.3070.0<br />

534.3080.0<br />

534.1006.0<br />

534.1015.0<br />

534.1025.0<br />

534.2090.0


We have been certif ed acc. to EN ISO 9001 and EN ISO 13485<br />

We have been certif ed acc. to EN ISO 9001 and EN ISO 13485<br />

Temp<br />

37<br />

set<br />

36-38°C<br />

0124<br />

0124<br />

°C<br />

Hygrotherm<br />

Technical Data<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

Ear irrigation / <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

Ear irrigation module (Hygrotherm) REF 530.2020.0<br />

Voltage range: 220 - 240 V~ ± 10 % 50/60 Hz<br />

Special voltage: 100 - 127 V~ ± 10 % 50/60 Hz<br />

Power consumption: 1500 W<br />

Water temperature<br />

Water flow:<br />

Temperature indication:<br />

36°C up to 38°C<br />

0-450 ml/min<br />

Accuracy ± 0,5 °C ± ½ digit<br />

Connections: - Power connection<br />

- Water supply<br />

- Water drainage<br />

- Connection for double-barrelled hose<br />

Ambient conditions:<br />

Transport/storage<br />

Ambient conditions:<br />

Operation:<br />

-20...+50°C; 5...90 % humidity without condensing,<br />

air pressure 700...1060 hPa<br />

+10...+35°C; 20...80 % humidity without condensing,<br />

air pressure 700...1060 hPa<br />

Classifications: Protection class (EN 60601-1)<br />

Degree of protection: type B;<br />

Classifcation acc. to Annex IX, EC directive 93/42/EEC: IIa<br />

You will find the ear irrigation module Hygrotherm on page 32!<br />

The stated technical data are valid at the moment of printing, subject to technical alterations!<br />

Thermal nystagmus stimulation / <strong>ATMOS</strong> S <strong>61</strong> <strong>ENT</strong> <strong>workstation</strong><br />

Thermal nystagmus stimulation (Variotherm) REF 530.2030.0<br />

Voltage range: 220 - 240 V~ ± 10 %, 50/60 Hz<br />

Special voltage: 100 - 127 V~, ± 10 % 50/60 Hz<br />

Power consumption: 1500 W<br />

Water temperature<br />

Irrigation mode: adjustable from 36°C up to 38°C<br />

Stimulation mode: adjustable from 20°C - 47°C, 2 channels<br />

Water flow:<br />

0-450 ml/min<br />

Temperature indication: Accuracy ± 0.8 °C ± ½ digit<br />

(can only be guaranteed with unchanged ambient<br />

conditions)<br />

Connections: - Power connection<br />

- Water supply<br />

- Water drainage<br />

- Connection for double-barrelled hose<br />

Ambient conditions: -20...+50°C; 5...90 % humidity without condensing, air<br />

Transport/storage<br />

pressure 700...1060 hPa<br />

Ambient conditions: +10...+35°C; 20...80 % humidity without condensing, air<br />

Operation<br />

pressure 700...1060 hPa<br />

Classifications: Protection class (EN 60601-1) I;<br />

Degree of protection: type B;<br />

Protection category: IPX0;<br />

Classifcation according to Annex IX,<br />

EC directive 93/42/EEC: IIa<br />

You will find the Variotherm (Thermal nystagmus stimulation) on page 33!<br />

The stated technical data are valid at the moment of printing, subject to technical alterations!<br />

E N T<br />

Technical Data<br />

<strong>ATMOS</strong><br />

S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

59


MedizinTechnik<br />

The stated technical data<br />

are valid at the moment<br />

of printing, subject to<br />

technical alterations!<br />

The stated technical data<br />

are valid at the moment<br />

of printing, subject to<br />

technical alterations!<br />

60<br />

Technical Data<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision / <strong>ENT</strong> cameras / brochure page 44<br />

<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision<br />

l Technical Data<br />

<strong>ATMOS</strong> Cam 31 / 31 DV<br />

<strong>ATMOS</strong> Cam 21 / 21 DV<br />

<strong>ATMOS</strong> Strobo 21 LED module<br />

<strong>ATMOS</strong> RS 221<br />

<strong>ATMOS</strong> SE 6501<br />

<strong>ATMOS</strong> Cam 31 <strong>ATMOS</strong> Cam 31 DV <strong>ATMOS</strong> Cam 21 <strong>ATMOS</strong> Cam 21 DV<br />

Resolution: 752 x 582 752 x 582 500 x 582 500 x 582<br />

Photosensitivity:<br />

(min. illumination) 0.25 lux 0.25 lux 0.15 lux 0.15 lux<br />

Image memory: 1- / 4 image mode 1- / 4 image mode - -<br />

Foot switch<br />

image memory<br />

l l - -<br />

Digital zoom 2 x 2 x 1,7 1,7<br />

Outputs:<br />

FBAS <br />

SVHS <br />

Digital DV:<br />

Firewire (IEEE 1394)<br />

- - <br />

Video norm PAL REF 531.2030.0 REF 531.2040.0 REF 531.2010.0 REF 531.2020.0<br />

Video norm NTSC on request - on request on request<br />

= standard l = option - = not available<br />

Technical Data <strong>ATMOS</strong> Cam 31 <strong>ATMOS</strong> Cam 21<br />

Resolution: 752 (H) X 582 (V) Pixel 500 (H) X 582 (V) Pixel<br />

Dynamics: 48 dB 48 dB<br />

Min. illumination: 0.25 lux 0.15 lux<br />

Connection for LED light source: yes (2 Watt, 50 Lumen) yes (2 Watt, 50 Lumen)<br />

Image memory: 1- resp. 4-image mode no<br />

Outputs: Y/C (S-VHS), FBAS (Video),<br />

<strong>ATMOS</strong> interlink, trigger output<br />

Y/C (S-VHS), FBAS (Video),<br />

<strong>ATMOS</strong> interlink, trigger output<br />

Endoscope connection: for lense funnel acc. to DIN 58105 for lense funnel acc. to DIN 58105<br />

Focal distance: optimised for endoscope (Ø 2,7 ... 10 mm) optimised f. endoscope (Ø 2,7 ... 10 mm)<br />

Power consumption: max. 35 VA max. 35 VA<br />

Mains supply: 100-240 V ~; 50-60 Hz 100-240 V ~; 50-60 Hz<br />

Operation time: continuous operation continuous operation<br />

Dimensions<br />

Control unit (W x H x D):<br />

138 x 116 x 265 mm 138 x 116 x 265 mm<br />

Weight control unit: 2.35 kg 2.35 kg<br />

Weight camera head<br />

incl. cable:<br />

235 g 235 g<br />

Ambient conditions: temperature: +10 - +35°C; air humidity: 30 – 80% rel. humidity without<br />

condensation; air pressure: 700 – 1060 hPa<br />

Classifications: protection category: IP20; protection class: I;<br />

class IIa (acc. to appendix IX; directive 93/42/EEC)<br />

Degree of protection of<br />

application parts:<br />

BF BF<br />

We have been certif ed acc. to EN ISO 9001 and EN ISO 13485


We have been certif ed acc. to EN ISO 9001 and EN ISO 13485<br />

Technical Data<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> vision / LED stroboscopy / brochure on page 45<br />

Technical Data <strong>ATMOS</strong> Strobo 21 LED<br />

Voltage: 100 - 240 V~, 50-60 Hz<br />

Power Consumption: 30 VA<br />

Flash frequency: 70 - 1000 Hz; ± 1 Hz without reduction<br />

Sound level measuring range: 70 - 125 dB<br />

Precision of<br />

Sound level display:<br />

± 1dB<br />

Microphone: airborne sound microphone, body sound adaption optional<br />

Operation modes: continuous lighting; slow motion 0,5 up to 2 Hz; freeze image 0°- 400° phase<br />

shifting<br />

Service life of LED light source: approx. 50,000 h<br />

Sound level: no noise emission<br />

Dimensions H x W x D: 118 x 139 x 280 mm<br />

Weight: 5 kg<br />

Classifications: class I; (acc. to appendix IX, EC directive 93/42/EEC)<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

E N T<br />

Technical Data<br />

This image also contains optional functions.<br />

<strong>61</strong>


MedizinTechnik<br />

62<br />

We have been certif ed acc. to EN ISO 9001 and EN ISO 13485<br />

We have been certif ed acc. to EN ISO 9001 and EN ISO 13485<br />

0124<br />

Technical Data<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy / Radio surgery system / brochure on page 51<br />

Technical Data <strong>ATMOS</strong> RS 221 <strong>ENT</strong> Radiosurgical system 2.2 MHz<br />

Nominal Voltage: 230 V ~<br />

Rated frequency : 50 Hz<br />

Fuses: 2 x T 1,6 A / H bei 230 V<br />

Output voltage: 500 V max. high level output voltage<br />

Output frequency: 2,2 MHz<br />

Max. coagulation performance: max 90 Watt at 1 kOhm<br />

Cutting performance: max 100 W at 1 kOhm<br />

Dimensions (H x W x D): 138 mm x 285 mm x 230 mm<br />

Weight: 4 kg<br />

Colour: grey-white (RAL 9002), dove-blue (RAL 5014)<br />

Classifications: protection degree: type BF; defibrillation-proof,<br />

class: IIb (acc. to appendix IX, EC directive 93/42/EEC)<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy / Smoke evacuation / brochure on page 54<br />

Technical Data Smoke evacuation <strong>ATMOS</strong> SE 6501<br />

Appliance air flow:<br />

Controlled 650 l/min ±10%; Turbo up to 800 l/min<br />

with 1.8 m hose<br />

free blower flow 1600 l/min<br />

Voltage: AtmoSafe Europe: 230 V~ 50 Hz; AtmoSafe World switchable:<br />

100 V~ 50-60 Hz or 120 V~ 50-60 Hz or 230 V~ 50-60 Hz<br />

Power consumption: approx. 400 W<br />

Operating time: Continuous operation<br />

Noise level: 52 dB (A) @ 1m (acc. to ISO 7779)<br />

Ambient conditions:<br />

-40...+70°C; 5...95 % rel. humidity, non-condensing<br />

Transport/storage<br />

air pressure 700...1060 hPa<br />

Ambient conditions:<br />

+10°...+40°C; 20...80 % rel. humidity, non-condensing<br />

during operation<br />

air pressure 700...1060 hPa<br />

Dimensions (H x W x D): 210 x 410 x 370 mm (without filter); 420 mm (with filter)<br />

Weight: 14 kg<br />

Classifications: protection class (EN 60601-1): I; degree of protection: type CF defibrillator<br />

protected; protection category: IPX 0; OT-Foot switch: IPX8;<br />

Office-Foot switch IPX1; class I; (acc. to appendix IX, EC directive 93/42/EEC)<br />

The stated technical data are valid at the moment of printing, subject to technical alterations!<br />

Please contact us via:<br />

<strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> therapy<br />

l Technial Data<br />

Radio surgery system<br />

Smoke evacuation system


The space miracle<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

63


MedizinTechnik<br />

Standard colour ocean<br />

(RAL 5005 signal blue)<br />

64<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong> –<br />

Order set A<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong> Order set A<br />

1 x <strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong> <strong>ENT</strong> <strong>workstation</strong><br />

Basic <strong>ENT</strong> treatment unit for modular configuration of<br />

suction equipment, ear irrigation, compressed air system<br />

and LED light system.<br />

(see page 28).<br />

2 x Clipboard<br />

for lateral expansion/connection of working surface<br />

n Instrument deposit with 1 tray (150 mm x 190 mm)<br />

n Holder for suction hose respectively LED light source<br />

(see page 28).<br />

4 x Instrument tray melamine, 190 x 150 mm<br />

(see page 83).<br />

Suction equipment<br />

1 x Suction system standard 40 l/min<br />

complete with suction hose, cannula adapter,<br />

DDS secretion container with overflow protection and<br />

bacterial filter. (see page 29).<br />

Compressed air system for medication sprayer<br />

1 x Compressed air module (integrated air compressor,<br />

max. 2 bar) for medication nebulization<br />

including handle, 3 medication bottles with medication<br />

sprayers and support for medication bottles, integrated in<br />

working surface.<br />

(see page 34).<br />

LED light package<br />

1 x Light module LED<br />

2 channels, for connection to the LED light source<br />

<strong>ATMOS</strong> LS 21 LED for use with scopes and/or for<br />

the LED headlight <strong>ATMOS</strong> HL 21 LED, module is<br />

switchable, only one channel is activated at a time.<br />

(see page 36.)<br />

1 x LED headlight <strong>ATMOS</strong> HL 21 LED<br />

n Light source, with long service life and highperformance<br />

white light LED<br />

n Service life 50,000 h<br />

n Infinitely adjustable focusing optic<br />

n Cable 2 m for connection to light module LED<br />

(see page 36).<br />

1 x LED light source <strong>ATMOS</strong> LS 21 LED<br />

for direct connection to scopes and laryngoscopes, with<br />

high-performance white light LED.(see page 89).<br />

<strong>ATMOS</strong> S <strong>61</strong> <strong>Servant</strong><br />

<strong>ENT</strong> <strong>workstation</strong><br />

l Order set A<br />

Besides the basic equipment images<br />

and specifications also contain optional<br />

functions.<br />

REF<br />

530.0000.0<br />

530.0010.0<br />

000.0746.0<br />

530.1010.0<br />

530.3010.0<br />

530.4010.0<br />

530.4020.0<br />

507.4600.0<br />

Please contact us via: <strong>ENT</strong>@atmosmed.com . Phone: +49 7653 689-374 . Fax: +49 7653 68986-374