9. Extended operator functions<br />

Menu 1: Photocell<br />

Photocells Gate movement, OPEN Gate movement, CLOSE<br />

2-wire photocells<br />

A1 A B C D Operation without photocell<br />

B1 A B C D Gate stops not active<br />

C1 A B C D not active Gate reverses completely 2<br />

D1 A B C D Gate stops Gate reverses completely 2<br />

E1 A B C D not active Gate reverses completely 2<br />

2-wire photocells and photocells with potential-free relay contacts<br />

F1 A B C D not active Gate reverses completely 2<br />

G1 A B C D Gate stops Gate reverses completely 2<br />

H1 A B C D not active Gate reverses completely 2<br />

I1 A B C D Gate stops Gate reverses completely 2<br />

J1 A B C D not active Gate reverses completely 2<br />

A Photocell OPEN (terminal XP62B)<br />

B Photocell CLOSE1 (terminal XP62A)<br />

C Photocell at terminals B9 and 34 (only in CLOSE direction) (normally closed contact only)<br />

D Photocell CLOSE2 (terminal XP62B)<br />

Photocell active<br />

Photocell not active<br />

Menu 2: Closing safety edge device<br />

Gate movement, OPEN Gate movement, CLOSE<br />

A2 Gate reverses a little 1 Gate reverses a little 1<br />

B2 Gate reverses a little 1 Gate reverses completely 2<br />

C2 Gate reverses completely 2 Gate reverses a little 1<br />

D2 Gate reverses completely 2 Gate reverses completely 2<br />

48 Manual for installation and operation, <strong>Comfort</strong> <strong>515</strong> <strong>accu</strong> GB (#85512)