<strong>SA</strong>LVADOR ESCODA S.A. ®<br />

www.salvadorescoda.com<br />

Provença, 392 1st and 2nd floor<br />

Phone +34 93 446 27 80<br />

Fax +34 93 456 90 32<br />

08025 BARCELONA (SPAIN)<br />

CHECK POSSIBLE UPDATING<br />

It does not generate electromagnetic alterations<br />

The MVD system does not create electromagnetic alterations<br />

because the compressor load and unload are mechanical<br />

movements. Those characteristics make the system<br />

proper for telecommunications companies and in all kinds<br />

of accuracy laboratories.<br />

E<br />

M<br />

W<br />

5 th<br />

7 th<br />

11 th<br />

13 th<br />

17 th<br />

19 th<br />

Inverter EMC Estándard Digital<br />

0 1 2 3 4 5<br />

Accurate temperature control<br />

Compared with the traditional centralized air conditioned<br />

the MVD can reach a 0.5 degrees accuracy<br />

(°C)<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

1 2 3 4 (Tiempo)<br />

TECHNICAL SPECIFICATIONS<br />

Longer pipes, wide height difference<br />

PRICE LIST<br />

The DIGITAL SCROLL system is the only one which<br />

doesn't have separation equipment of gas/liquid and oil.<br />

In the load stage the refrigerant speed is enough to<br />

return the oil to the compressor. During the download<br />

phase, there is no refrigerant outlet so there is no oil<br />

discharge.<br />

Advanced technology<br />

The DIGITAL SCROLL, compressor when is in a load stage,<br />

the motor speed ensures that the refrigerant has<br />

enough capacity to recover all the oil back to the compressor.<br />

During the download phase ther is no oil moving outside<br />

the compressor, because there is no refrigerant outlet.<br />

The refrigerant may also recover the oil back to the compressor.<br />

Model D252W D280W D335W D400W D450W<br />

Code CL 23 010 CL 23 011 CL 23 012 CL 23 013 CL 23 014<br />

COOLING capacity kW 25,2 28,0 33,5 40,0 45,0<br />

HEATING capacity kW 27,0 31,5 35,0 43,0 47,0<br />

Air flow m 3 /h 10.000 10.000 10.000 14.000 14.000<br />

Sound level dB(A) 58 58 58 60 60<br />

Dimensions<br />

150m 150m: Distancia máxima de tubo entre la unidad interior y exterior.<br />

50m 50m: Diferencia de altura máxima entre la unidad interior y exterior.<br />

15m 15m: Diferencia de altura máxima entre unidades interiores.<br />

Net mm 980x1630x800 980x1630x800 980x1630x800 1380x1630x830 1380x1630x830<br />

Packing mm 1040x1780x840 1040x1780x840 1040x1780x840 1440x1800x860 1440x1800x860<br />

Weight<br />

Net<br />

Gross<br />

Kg<br />

Kg<br />

245<br />

260<br />

245<br />

260<br />

245<br />

260<br />

396<br />

416<br />

396<br />

416<br />

Pipes maximum lenght mm 175 175 175 175 175<br />

Max. height difference between interior and<br />

exterior units<br />

15 15 15 15 15<br />

Max. height difference between interior<br />

units<br />

50 50 50 50 50<br />

Maximum number of interior units 1x13 1x16 1x16 1x16 1x20<br />