14<br />

Mica Slim<br />

Technical Data<br />

LED<br />

(Pre-fixed PCB)<br />

Monochromatic versions:<br />

Mica Slim SS: 1x1.2W<br />

Mica Slim S: 3x1.2W<br />

Mica Slim A: 4x2W<br />

Mica Slim I: 7x2W<br />

RGB versions<br />

For guidance:<br />

Mica Slim I: 4x3x1.2W with<br />

multichip RGB<br />

For Illumination:<br />

Mica Slim I: 7x2W (RRGGGBB)<br />

Lamps<br />

Mica Slim A:<br />

20W/35W HIT-TC-CE (MT)<br />

Metal halide, cap: PGJ5<br />

Mica Slim I:<br />

35W HIT (MT)<br />

Metal halide, cap: G12<br />

Materials/Finish<br />

Body: LM6 marine grade die-cast<br />

aluminium with powder coated<br />

for high corrosion resistance.<br />

Frame: 316 Stainless steel (3mm<br />

thick).<br />

Retaining screws: stainless steel<br />

Front glass: toughened<br />

semi-frosted or frosted sodic<br />

glass.<br />

Glass thicknesses:<br />

Mica Slim A and I: 19mm. Mica<br />

Slim SS and S: 15mm.<br />

Gasket: anti-ageing silicon.<br />

Recessing box: polypropylene.<br />

Cable:<br />

H07RN-F 0.5m long<br />

All versions have integral power<br />

supply.<br />

All versions have electronic<br />

ballast.<br />

Installation/Mounting<br />

Luminiares delivered complete<br />

with body, recess box, frame and<br />

glass. All versions are pre-wired,<br />

with a 0.5m cable.<br />

For outdoor applications, 30cm<br />

drainage gravel or any equivalent<br />

drainage system must be used<br />

beneath the housing to ensure<br />

water can evacuate. The recessed<br />

box can be embedded in asphalt<br />

with good drainage once the<br />

temperature of the asphalt is<br />

approximately 80°C.<br />

Luminaire must be operated for<br />

45 minutes without its front glass<br />

to avoid moisture build-up inside<br />

the housing.<br />

Can be installed in areas with a<br />

maximum low speed of<br />

30km/hr.<br />

To facilitate quick installation, the<br />

wiring can be done via to IP67<br />

wiring connectors (SAP codes<br />

96257910 or 96257911). For<br />

through wiring, IP67 connection<br />

boxes can be used (SAP codes<br />

96257907, 96257908 or<br />

96257909).<br />

All versions have integral power<br />

supply.<br />

The maximum static load is<br />

5000kg.<br />

Colour change RGB lighting<br />

technology available in<br />

Mica Slim I for guidance or<br />

illumination. For RGB versions,<br />

LEDs are driven by DMX control<br />

(not supplied).<br />

Standards<br />

Design and manufactured to<br />

comply with AS/NZS 60598.<br />

Class I Electrical.<br />

IK 10.<br />

IP67.