3. Function of the ramp - generator:<br />

3.1 Normal - or high - frequency - operation - mode:<br />

The adjustment of the ramp - time is made by trimpot P2.<br />

With DS 5 ‘off’ the range of t is 0.1 ... 15 sec. ( for a frequ. step of 150 Hz resp. 600 Hz )<br />

With DS 5 ‘on’ the range of t is 1.5 ... 250sec.<br />

3.2 In the mode ‘pump - operation’ the ramp - time is fixed to 7 sec. ( for a frequ. step of 55 Hz ).<br />

3.3 In the operation - mode ‘200 Hz’ the ramp time is fixed to 1 sec.<br />

4. Electrical connection and examples for the control of the drive:<br />

4.1 Control by potentiometer:<br />

F D<br />

T<br />

OK<br />

8 7 6 5 4 3 2 1<br />

D = direction<br />

F = enable<br />

T = Motor-temp.<br />

OK = Inverter OK<br />

set-point<br />

U<br />

V<br />

motor<br />

3x230V<br />

W PE N<br />

L1<br />

L1<br />

N<br />

PE<br />

mains 230 VAC<br />

Technical description for <strong>MFR</strong> 600/1500 4