<strong>11</strong>. Master Casts<br />

% No significant bubbles or flaws in stone<br />

% Teeth not fractured from cast<br />

% Includes all anatomical surfaces of final impressions<br />

% Includes 3-4 mm. land area<br />

% Base approximately parallel to ridge and approximately 1/2 inches thick (minimum)<br />

% Evidence of a dense stone surface<br />

% Clean and well trimmed<br />

% Infection Control/Judgment/Other _________________________________<br />

12. Survey of Master Cast<br />

% Height-of-contour lines indicated on all possible abutments<br />

% Acceptable path of insertion, with parallel guide planes<br />

% Cast tripodized<br />

% Retention areas indicated<br />

% Guiding planes indicated<br />

% Height of contour indicated<br />

% Infection Control/Judgment/Other _________________________________<br />

13. Framework Design and Prescription<br />

(Draw on duplicate cast, have marked, then submit with master cast and completed prescription)<br />

% Major connector designed correctly<br />

% Direct retainers designed correctly<br />

% Neatly and accurately drawn<br />

% Lab prescription legibly, accurately completed<br />

% Infection Control/Judgment/Other _________________________________<br />

14. Framework Adjustment<br />

% Framework elements seat completely (tissue contact verified)<br />

% Framework does not interfere with occlusion<br />

% Proper use of indicating medium<br />

% Framework elements of proper proportions<br />

% Framework elements correct distance from abutments, embrasures<br />

% Framework stable, does not rock<br />

% Passive when seated<br />

% No soft tissue impingement (check with PIP.)<br />

% Adequate finish and polish<br />

% Infection Control/Judgment/Other _________________________________<br />

15. Altered Cast Impression (Distal extensions, extensive tooth-borne cases)<br />

% Acrylic tray securely attached to framework, properly extended<br />

% Framework passive when fully seated intraorally , stable with impression in place<br />

% No impression material under direct retainers, major or minor connectors<br />

% Correctly border molded<br />

% Accurately records available supporting structures<br />

% No significant areas of "burn through"<br />

% Peripheries covered by a thin layer of impression material<br />

% No significant voids<br />

% Infection Control/Judgment/Other _________________________________<br />