RPD Manual 11 - Removable Prosthodontics - Dalhousie University
RPD Manual 11 - Removable Prosthodontics - Dalhousie University
RPD Manual 11 - Removable Prosthodontics - Dalhousie University
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>11</strong>. Master Casts<br />
% No significant bubbles or flaws in stone<br />
% Teeth not fractured from cast<br />
% Includes all anatomical surfaces of final impressions<br />
% Includes 3-4 mm. land area<br />
% Base approximately parallel to ridge and approximately 1/2 inches thick (minimum)<br />
% Evidence of a dense stone surface<br />
% Clean and well trimmed<br />
% Infection Control/Judgment/Other _________________________________<br />
12. Survey of Master Cast<br />
% Height-of-contour lines indicated on all possible abutments<br />
% Acceptable path of insertion, with parallel guide planes<br />
% Cast tripodized<br />
% Retention areas indicated<br />
% Guiding planes indicated<br />
% Height of contour indicated<br />
% Infection Control/Judgment/Other _________________________________<br />
13. Framework Design and Prescription<br />
(Draw on duplicate cast, have marked, then submit with master cast and completed prescription)<br />
% Major connector designed correctly<br />
% Direct retainers designed correctly<br />
% Neatly and accurately drawn<br />
% Lab prescription legibly, accurately completed<br />
% Infection Control/Judgment/Other _________________________________<br />
14. Framework Adjustment<br />
% Framework elements seat completely (tissue contact verified)<br />
% Framework does not interfere with occlusion<br />
% Proper use of indicating medium<br />
% Framework elements of proper proportions<br />
% Framework elements correct distance from abutments, embrasures<br />
% Framework stable, does not rock<br />
% Passive when seated<br />
% No soft tissue impingement (check with PIP.)<br />
% Adequate finish and polish<br />
% Infection Control/Judgment/Other _________________________________<br />
15. Altered Cast Impression (Distal extensions, extensive tooth-borne cases)<br />
% Acrylic tray securely attached to framework, properly extended<br />
% Framework passive when fully seated intraorally , stable with impression in place<br />
% No impression material under direct retainers, major or minor connectors<br />
% Correctly border molded<br />
% Accurately records available supporting structures<br />
% No significant areas of "burn through"<br />
% Peripheries covered by a thin layer of impression material<br />
% No significant voids<br />
% Infection Control/Judgment/Other _________________________________<br />
<strong>RPD</strong> Checklist - 99