5.4 Vertical Index Zero Setting (V 0S<strong>ET</strong>)<br />

operation display<br />

Turn on the instrument. Displaying ―b‖ means that<br />

the vertical axis is not vertical. If the instrument is<br />

leveled exactly, ―b‖ will disappear.<br />

After the instrument is leveled exactly, turn on the<br />

instrument and it displays ―V 0S<strong>ET</strong>‖ which means<br />

that the vertical index has been set to zero.<br />

Turn the telescope up and down in normal position<br />

in horizontal direction. Vertical index zero is set<br />

when the telescope passes level and the vertical<br />

angle is displayed. The instrument is now ready<br />

for angle measurement.<br />

If vertical index automatic compensation set is used, the vertical index can be<br />

compensated. When the vertical index is beyond the designed criterion, “b” will be<br />

displayed. Level the instrument precisely until “b” disappears. Then the instrument<br />

gets its breath again.<br />

If no operation is performed in 10 or 30 minutes. The power will be turned off<br />

automatically due to “power auto off function” and the horizontal angle will be stored<br />

in memory automatically.<br />