<strong>Hardware</strong> <strong>Reference</strong> 51<br />

C613-03020-00 REV J<br />

Figure 28 shows a typical output. The status of the test will be shown in the<br />

right-hand column. For further information on the meanings of the other<br />

figures, see the “Test Facility” chapter of your switch’s Software <strong>Reference</strong>.<br />

Figure 28: Example output from the show test command for a <strong>Rapier</strong> switch with an AT-AR061 ECPAC installed<br />

Board ID Bay Board Name Rev Serial number<br />

--------------------------------------------------------------------------<br />

--<br />

Base 86 AT-RP24 <strong>Rapier</strong> 24 M2-1 46690596<br />

NSM 4PIC 87 AT-AR040-00 NSM 4PIC M3-3 6845206<br />

PIC 38 1 AT-AR023-00 PIC Sync M1-1 8618528<br />

PAC 153 AR061 ECPAC P1-16 6844578<br />

Duration Details<br />

Interface State Result Type (minutes) Data( %OK )<br />

Control<br />

--------------------------------------------------------------------------<br />

port1 no test - - - - - -<br />

port2 no test - - - - - -<br />

port3 no test - - - - - -<br />

port4 no test - - - - - -<br />

port5 no test - - - - - -<br />

port6 no test - - - - - -<br />

port7 no test - - - - - -<br />

port8 no test - - - - - -<br />

port9 no test - - - - - -<br />

port10 no test - - - - - -<br />

port11 no test - - - - - -<br />

port12 no test - - - - - -<br />

port13 no test - - - - - -<br />

port14 no test - - - - - -<br />

port15 no test - - - - - -<br />

port16 no test - - - - - -<br />

port17 no test - - - - - -<br />

port18 no test - - - - - -<br />

port19 no test - - - - - -<br />

port20 no test - - - - - -<br />

port21 no test - - - - - -<br />

port22 no test - - - - - -<br />

port23 no test - - - - - -<br />

port24 no test - - - - - -<br />

syn0 no test - - - - - -<br />

asyn0 no test - - - - - -<br />

enco0 testing wait 4 minutes DES < 1 good(100.0) -<br />

.<br />

enco1 testing wait 4 minutes STAC < 1 good(100.0) -<br />

.<br />

---------------------------------------------------------------------------<br />

If you are unsure about running the Test Facility, or have difficulty evaluating<br />

the results then contact your authorised <strong>Allied</strong> <strong>Telesis</strong> distributor or reseller.