HIGS<br />

<strong>High</strong>ly integrated<br />

generator switchgear<br />

With the highly integrated generator<br />

switchgear, <strong>Siemens</strong> enables more functionality<br />

on less space. For the first time,<br />

the neutral treatment of the generator as<br />

well as the auxiliary feeder are integrated<br />

in a single generator switchgear. The<br />

switchgear can be installed both indoors<br />

<strong>and</strong> outdoors: close to the generator,<br />

without expensive cabling.<br />

All functions are therefore available out<br />

of one h<strong>and</strong> – without time-consuming<br />

coordination between different suppliers,<br />

which offers considerable cost savings<br />

due to ...<br />

... lower expenditure for:<br />

<br />

<br />

<br />

Planning<br />

Investment<br />

Installation<br />

… lower dem<strong>and</strong> for:<br />

<br />

<br />

<br />

Space<br />

Material (cabling)<br />

Service<br />

Technical data<br />

Air-insulated, metal-enclosed<br />

For indoor <strong>and</strong> outdoor installation<br />

Rated voltage: Max. 13.8 kV<br />

(110 kV BIL / 50 kV PFWV)<br />

Rated short-circuit-breaking current I SC :<br />

31.5 – 63 kA<br />

Rated normal current: 2,000 – 3,150 A<br />

Circuit-breaker:<br />

<strong>Generator</strong> circuit-breaker according<br />

to IEEE C37.013, or circuit-breaker<br />

according to IEC 62271-100<br />

Dimensions (L x W x H):<br />

3,430 x 1,200 x 2,500 mm<br />

Equipment (optional):<br />

<strong>Generator</strong> circuit-breaker in<br />

the main transformer feeder<br />

Disconnector in the main<br />

transformer feeder<br />

Earthing switch on generator<br />

<strong>and</strong> transformer side<br />

<strong>Current</strong> <strong>and</strong> voltage transformers<br />

Surge arresters<br />

Surge capacitors<br />

Options:<br />

Integrated auxiliary feeder with<br />

disconnector <strong>and</strong> generator circuitbreaker<br />

or with switch-disconnector<br />

<strong>and</strong> fuses<br />

8BK40<br />

Metal-enclosed generator switchgear<br />

with truck-type circuit-breaker<br />

Technical data<br />

Air-insulated, metal-enclosed<br />

For indoor installation<br />

Rated voltage: Max. 17.5 kV<br />

(95 kV BIL / 38 kV PFWV)<br />

Rated short-circuit-breaking current I SC :<br />

50 kA / 63 kA<br />

Rated normal currents:<br />

Rated normal current of the<br />

busbar, max. 5,000 A<br />

Rated normal current of the<br />

feeder, max. 5,000 A<br />

Circuit-breaker:<br />

<strong>Generator</strong> circuit-breaker according<br />

to IEEE C37.013, or circuit-breaker<br />

according to IEC 62271-100<br />

Dimensions (L x W x H):<br />

2,300 x 1,100 x 2,500 mm<br />

Equipment (optional):<br />

<br />

<br />

<br />

<br />

<br />

<br />

<strong>Generator</strong> circuit-breaker<br />

Disconnecting function by means<br />

of truck-type circuit-breaker<br />

Earthing switch on generator <strong>and</strong><br />

transformer side<br />

<strong>Current</strong> <strong>and</strong> voltage transformers<br />

Surge arresters<br />

Surge capacitors<br />