Non-regulatory Information<br />
NHBC St<strong>and</strong>ards 2010<br />
NHBC accepts the use of <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> <strong>and</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus, when installed <strong>and</strong><br />
used in accordance with this Certificate, in relation to NHBC St<strong>and</strong>ards, Chapters 5.1, Substructure <strong>and</strong> ground<br />
bearing floors, 5.2 Suspended ground floors <strong>and</strong> 6.4 Timber <strong>and</strong> concrete upper floors.<br />
Technical Specification<br />
1 Description<br />
1.1 <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> <strong>and</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus are unfaced, plain-edged slabs<br />
manufactured from high-density mineral wool (rock) which is resin-bonded with ECOSE (1) Technology binder <strong>and</strong> is<br />
water repellent.<br />
(1) ECOSE is a registered trademark of <strong>Knauf</strong> <strong>Insulation</strong> Ltd.<br />
1.2 The slabs have the nominal characteristics as shown in Table 1.<br />
Table 1 Nominal characteristics<br />
Length<br />
Width<br />
<strong>Insulation</strong> thickness<br />
Declared overall thermal conductivity<br />
Minimum compressive strength<br />
Nominal density<br />
Edge detail<br />
<strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus<br />
900 mm<br />
600 mm<br />
25 mm<br />
0.036 W·m –1 ·K –1<br />
10 KPa<br />
100 kg·m –3<br />
Square<br />
Page 3 of 12<br />
900 mm<br />
600 mm<br />
25, 30, 40 <strong>and</strong> 50 mm<br />
0.036 W·m –1 ·K –1<br />
10 KPa<br />
140 kg·m –3<br />
Square<br />
2 Delivery <strong>and</strong> site h<strong>and</strong>ling<br />
2.1 The slabs are delivered to site in weatherproof Supakube packaging. Each pack carries a label bearing<br />
the manufacturer’s name, product description, essential instructions for installation <strong>and</strong> the BBA identification mark<br />
incorporating the number of this Certificate.<br />
2.2 The slabs must be stored under cover until required for use.<br />
Assessment <strong>and</strong> Technical Investigations<br />
The following is a summary of the assessment <strong>and</strong> technical investigations carried out on <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong><br />
<strong>and</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus.<br />
Design Considerations<br />
3 General<br />
3.1 <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> <strong>and</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus are used as a resilient layer for acoustic<br />
insulation of intermediate timber-based separating floors <strong>and</strong> intermediate concrete floors respectively, <strong>and</strong> are also<br />
effective in reducing the thermal transmittance (U value) of new or existing concrete floors, when used as a double layer.<br />
3.2 <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> is a suitable resilient layer in timber platform floors, Type 3 in new build <strong>and</strong> <strong>Floor</strong><br />
Treatment/Type 2 in conversions <strong>and</strong> <strong>Earthwool</strong> <strong>Acoustic</strong> <strong>Floor</strong> <strong>Slab</strong> Plus is suitable in FFT4 in E-FC-1 <strong>and</strong> E-FC-2<br />
Robust Details.<br />
3.3 The slabs must not be used where they may come into contact with moisture from the ground.<br />
3.4 Ground-supported concrete floors incorporating the slabs must include a suitable damp-proof membrane laid in<br />
accordance with the relevant clauses of CP 102 : 1973, BS 8102 : 1990 <strong>and</strong>/or BS 8215 : 1991.<br />
3.5 Suspended concrete ground floors incorporating the boards must include a damp-proof membrane or suitable<br />
ventilation of the sub-floor as appropriate.<br />
3.6 The overlay to the slabs should be:<br />
a cement-based floor screed, laid in accordance with the relevant clauses of BS 8204-1 : 2003 <strong>and</strong>/or<br />
BS 8204-2 : 2003, <strong>and</strong> BS 8000-9 : 2003, or<br />
wood-based floor, eg tongue-<strong>and</strong>-groove, flooring grade particle board (Type P5 or P7) to BS EN 312 : 2003<br />
or oriented str<strong>and</strong> board of type OSB/3 or OSB/4 to BS EN 300 : 2006, 18 mm thick (minimum), installed in<br />
accordance with DD CEN/TS 12872:2007, or<br />
a concrete slab in accordance with BS 8204-1 : 2003 <strong>and</strong> BS 8204-2 : 2003.