<strong>Is</strong> a <strong>bolted</strong> <strong>pressure</strong> <strong>contact</strong> <strong>switch</strong> <strong>the</strong> <strong>main</strong><br />
disconnect for your facility?<br />
Bolted <strong>pressure</strong> <strong>contact</strong> <strong>switch</strong> solutions from <strong>Schneider</strong> Electric Services<br />
Without proper <strong>main</strong>tenance, <strong>the</strong> operating mechanism<br />
of a <strong>bolted</strong> <strong>pressure</strong> <strong>contact</strong> <strong>switch</strong> may become hard to<br />
operate or inoperable.<br />
Make <strong>the</strong> most of your energy SM<br />
.<br />
Increase <strong>the</strong> reliability of your electrical distribution system<br />
Through <strong>the</strong> years <strong>bolted</strong> <strong>pressure</strong> <strong>contact</strong> <strong>switch</strong>es have been installed as <strong>the</strong><br />
<strong>main</strong> disconnect for facilities all over <strong>the</strong> country and most facility personnel never<br />
give <strong>the</strong>m a second thought. A <strong>bolted</strong> <strong>pressure</strong> <strong>switch</strong> can typically be identified<br />
by its long operating handle that compresses <strong>the</strong> operating mechanism spring.<br />
Periodic <strong>main</strong>tenance, cleaning and lubrication of a <strong>bolted</strong> <strong>pressure</strong> <strong>contact</strong><br />
<strong>switch</strong> is required to provide reliable operation. Failure to properly <strong>main</strong>tain<br />
this <strong>switch</strong> could result in costly downtime, especially if it serves as <strong>the</strong> <strong>main</strong><br />
disconnect for your entire facility. <strong>Schneider</strong> Electric Services provides a range<br />
of services designed to extend <strong>the</strong> life of your <strong>bolted</strong> <strong>pressure</strong> <strong>contact</strong> <strong>switch</strong><br />
and increase <strong>the</strong> reliability of your electrical distribution system. Based upon<br />
your specific needs or preferences, we offer:<br />
• Preventive <strong>main</strong>tenance for your existing <strong>switch</strong><br />
• Replacement and upgrade of your existing <strong>switch</strong> with a <strong>Square</strong> D <br />
Type B-L Bolt-Loc <strong>switch</strong><br />
• A retrofill solution with <strong>the</strong> <strong>Square</strong> D Masterpact NW circuit breaker
Preventive <strong>main</strong>tenance solutions<br />
Experienced <strong>Schneider</strong> Electric Services technicians<br />
perform a comprehensive scope of work, based<br />
upon manufacturers’ specifications for all<br />
rated <strong>switch</strong>es.<br />
Preventive <strong>main</strong>tenance, including visual inspection<br />
and exercising <strong>the</strong> operating mechanism, should be<br />
performed at a minimum of once a year. Thorough<br />
cleaning and lubrication should occur every three<br />
to five years, depending upon <strong>the</strong> amount of usage<br />
and ambient conditions. Molybdenum disulfide<br />
grease is recommended for <strong>the</strong> <strong>Square</strong> D Bolt-Loc<br />
<strong>switch</strong>; refer to <strong>the</strong> <strong>Square</strong> D Services Lubrication<br />
Manual (Catalog #0100DB0802) for o<strong>the</strong>r<br />
manufacturers’ recommendations.<br />
Replacement and upgrade solutions<br />
This option provides a complete new Type B-L<br />
Bolt-Loc Switch replacement and accessory<br />
upgrade for old or inoperable <strong>bolted</strong> <strong>pressure</strong><br />
<strong>contact</strong> <strong>switch</strong>es. This solution includes:<br />
• Remove and dispose of <strong>the</strong> old/inoperable <strong>switch</strong><br />
• Clean and inspect <strong>the</strong> <strong>switch</strong> compartment,<br />
including bus connections<br />
• Identify damaged or non-functioning accessories<br />
• Install <strong>the</strong> new Type B/L Bolt-Loc Switch, which is<br />
covered by a one-year warranty<br />
• Reconnect all accessory wiring and install<br />
accessories (existing and/or new)<br />
• Accessory replacement or repair can be provided<br />
at an additional charge<br />
• Perform <strong>Schneider</strong> Electric Services standard<br />
start-up procedure for low voltage air <strong>switch</strong>es<br />
For more information<br />
888-778-2733<br />
Safety first. Our field<br />
service representative<br />
verifies <strong>the</strong> <strong>switch</strong> has<br />
been de-energized prior to<br />
performing <strong>main</strong>tenance<br />
and testing.<br />
www.schneider-electric.us/go/services<br />
<strong>Schneider</strong> Electric USA, Inc.<br />
9870 Crescent Park Drive<br />
West Chester, OH 45069<br />
Tel: 513-777-4445<br />
Fax: 513-755-5028<br />
www.schneider-electric.us<br />
Document Number 1910HO0804R05/11<br />
Retrofill solution<br />
<strong>Schneider</strong> Electric Services offers a retrofill solution<br />
that reconfigures <strong>the</strong> <strong>switch</strong> compartment to accept<br />
a new Masterpact NW circuit breaker. Utilizing<br />
<strong>the</strong> existing structure represents an economical<br />
alternative to purchasing new equipment.<br />
Using <strong>the</strong> upgraded technology of our Masterpact<br />
NW insulated case circuit breaker, a retrofill solution<br />
provides solid state protection and reduces<br />
<strong>main</strong>tenance requirements. In fact, under normal<br />
operating conditions, Masterpact circuit breakers<br />
require minimal <strong>main</strong>tenance.<br />
A <strong>Square</strong> D Masterpact NW low-voltage circuit<br />
breaker is retrofilled into <strong>the</strong> <strong>switch</strong> compartment of<br />
<strong>the</strong> old <strong>bolted</strong> <strong>pressure</strong> <strong>switch</strong>. The retrofill solution<br />
includes <strong>the</strong> associated draw-out mechanism,<br />
doors, wiring, metering, bus connectors, fasteners,<br />
and hinges.<br />
Masterpact circuit breakers can also:<br />
• Enhance coordination by <strong>the</strong>ir adjustability<br />
• Provide integral ground-fault protection<br />
for equipment<br />
• Provide high interrupting ratings and<br />
withstand ratings<br />
• Provide communications<br />
• Provide power monitoring<br />
• Provide protective relaying functions<br />
• Provide zone-selective interlocking (ZSI) which<br />
can reduce damage in <strong>the</strong> event of a fault<br />
In addition, <strong>Schneider</strong> Electric Services<br />
provides on-site services, equipment testing<br />
and project management.<br />
Masterpact NW power circuit breakers are designed<br />
to protect electrical systems from damage caused by<br />
overloads, short circuits, and equipment ground faults.<br />
All Masterpact circuit breakers are designed to open and<br />
close a circuit manually, and to open <strong>the</strong> circuit automatically<br />
at a predetermined overcurrent setting.<br />
Why choose<br />
Electrical Distribution<br />
Services from<br />
<strong>Schneider</strong> Electric<br />
As part of <strong>Schneider</strong><br />
Electric, The Global<br />
Specialist in Energy<br />
Management , <strong>the</strong><br />
Electrical Distribution<br />
Services group offers<br />
engineered solutions<br />
designed to promote<br />
workplace safety, lower<br />
life-cycle cost, and<br />
increase power system<br />
reliability to industrial,<br />
utility, and commercial<br />
customers throughout<br />
<strong>the</strong> United States.<br />
Our commitment is<br />
to provide you with<br />
innovative solutions,<br />
best-in-class customer<br />
service and project<br />
management,<br />
advanced technical<br />
knowledge, and<br />
exceptional quality in<br />
everything we do.<br />
This document has been<br />
printed on recycled paper<br />
June 2011<br />
© 2011 <strong>Schneider</strong> Electric. All Rights Reserved. <strong>Schneider</strong> Electric, Bolt-Loc, Masterpact, Make <strong>the</strong> most of your energy, <strong>the</strong> global specialist in energy<br />
management, <strong>Square</strong> D, and <strong>the</strong> D-in-a-square logo are trademarks owned by <strong>Schneider</strong> Electric Industries SAS or its affiliated companies. 998-4720