CABLE PULLING LUBRICANTS<br />

<strong>Cable</strong> Pulling Lubricant Selection Guide<br />

aPPliCatioN<br />

sPeCiFiCatioNs<br />

= new producT = Replacement paRt = accessoRy<br />

<strong>Cable</strong>-Cream ®<br />

www.greenlee.com<br />

Winter-Gel <br />

Application Temperature Range (°F) 20°F - 190°F 20°F - 190°F 20°F - 190°F -25°F - 190°F<br />

Application Temperature Range (°C) -6°C - 88°C -6°C - 88°C -6°C - 88°C -31°C - 88°C<br />

Minimum Storage Temperature 30° F/-1 C 30° F/-1 C 30° F/-1 C -25° F/-31 C<br />

Base Polymer Wax Polymer Polymer<br />

Average Coefficient of Friction* 0.26 0.11 0.18 0.21<br />

Color Clear Yellow Blue/Green Blue<br />

CoMPatiBility (<strong>Cable</strong> type)<br />

Rubber ✓ ✓ ✓ ✓<br />

Neoprene ✓ ✓ ✓ ✓<br />

Nylon ✓ ✓ ✓ ✓<br />

PVC ✓ ✓ ✓ ✓<br />

High-density or cross linked polyethylene ✓ ✓ ✓ ✓<br />

Low-density polyethylene ✓ ✓ ✓ ✓<br />

Semiconducting jacket ✓ ✓ ✓ ✓<br />

Hypalon ✓ ✓ ✓ ✓<br />

*(IEEE 375-2 test procedure) kinetic coefficient of friction tested at 300 lb/ft sidewall bearing pressure<br />

<strong>Cable</strong> Lubricant Quantity Chart<br />

Clear Lube <br />

Electrical or<br />

datacom use.<br />

Clear <strong>and</strong> colorless<br />

for easy cleanup.<br />

Electrical use.<br />

Heavy Duty<br />

lubricant adheres<br />

well to cable<br />

without messy<br />

dripping.<br />

The following equation is a general guideline to determine the amount of cable lubricant<br />

to use for an average cable pull.<br />

Q = 0.0015 x l x D<br />

Where:<br />

Q = Quantity of cable lubricant to use in gallons<br />

L = Length of cable pull in feet<br />

D = Diameter of conduit or duct in inches<br />

If the following situations apply, consider using additional lubricant:<br />

• The cable jacket is hard <strong>and</strong>/or cable is very stiff.<br />

• The conduit is rough or dirty.<br />

• There are many bends to pull through.<br />

• The percentage of conduit filled by the cable is unusually high.<br />

• The conduit is water filled.<br />

<strong>Cable</strong>-Gel ®<br />

Electrical or<br />

datacom use.<br />

Cleans up quickly,<br />

non-staining.<br />

Can be applied by<br />

h<strong>and</strong> or pump.<br />

Electrical or<br />

datacom use.<br />

Will not freeze<br />

until 25°F. Can be<br />

applied by h<strong>and</strong><br />

or pump.<br />

PUll leNgtH 1" 2" 3" 4"<br />

200' 0.3 gal. 0.6 gal. 0.9 gal. 1.2 gal.<br />

300' 0.5 gal. 0.9 gal. 1.4 gal. 1.8 gal.<br />

400' 0.6 gal. 1.2 gal. 1.8 gal. 2.4 gal.<br />

600' 0.9 gal. 1.8 gal. 2.7 gal. 3.6 gal.<br />

800' 1.2 gal. 2.4 gal. 3.6 gal. 4.8 gal.<br />

1000' 1.5 gal. 3.0 gal. 4.5 gal. 6.0 gal.<br />

<strong>Cable</strong> Pulling<br />

USA CANADA INTERNATIONAL<br />

Tel: 800.435.0786 Tel: 800.435.0786 Tel: +1.815.397.7070<br />

Fax: 800.451.2632 Fax: 800.524.2853 Fax: +1.815.397.9247<br />