Fit the outer suction cover (132) and fine-adjust it<br />
against the impeller using the nuts (27) so that a<br />
minimum and uniform clearance is obtained between<br />
the impeller and the suction cover.<br />
Use a socket, extension bar and handle on the impeller<br />
screw (9). Turn the shaft around during fine adjustment<br />
to make sure it is not seizing anywhere.<br />
Fit the strainers.<br />
NOTE!<br />
For major overhaul instructions please refer to<br />
the workshop <strong>manual</strong> for this product or contact<br />
your local <strong>Grindex</strong> representative.<br />