ThermoCYCLE - Forstner Speichertechnik GmbH
ThermoCYCLE - Forstner Speichertechnik GmbH
ThermoCYCLE - Forstner Speichertechnik GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
How does <strong>ThermoCYCLE</strong> ® work?<br />
Warm grey water<br />
(Wastewater from bath, shower,<br />
washing machine… no wastewater<br />
containing faeces, oil or fat).<br />
In a separate wastewater supply pipe ➀ the warm<br />
grey water (from the shower, the washing<br />
machine...) feeds through the <strong>ThermoCYCLE</strong> ® . An<br />
ingenious filter system ➁ ensures that contaminants<br />
in the grey water (such as hair, fluff or<br />
sand…) are kept back. The heat exchanger ➂<br />
extracts the heat contained in the filtered grey<br />
water. The cooled wastewater ➃ then flows into<br />
the sewers. The fully automatic filter cleaning system<br />
➄ flushes out any contaminants ➅ at individually<br />
definable intervals, also feeding them into the<br />
sewers. This ensures smooth operation without<br />
disruption. A bypass ➆ also ensures guaranteed,<br />
smooth flow.<br />
FORSTNER ® Hygienic Storage System<br />
The exact stratification of the FORSTNER HS<br />
enables maximum utilisation of the heat energy<br />
recovered using <strong>ThermoCYCLE</strong> ® . For this reason<br />
the <strong>ThermoCYCLE</strong> ® can only be used in combination<br />
with this technology system.<br />
100 % <strong>Forstner</strong><br />
Bypass<br />
We offer innovative solutions in the sector of heat<br />
storage systems and heat recovery technology.<br />
High quality awareness and progressive thinking<br />
are what makes us stand out.<br />
SIMPLE – LOGICAL – BETTER!<br />
<strong>Forstner</strong> <strong>Speichertechnik</strong> <strong>GmbH</strong><br />
Neulandstrasse 36, 6971 Hard, Austria<br />
www.speichertechnik.com<br />
➃<br />
➆<br />
Cooled grey water or<br />
contaminants feed off<br />
➀<br />
Contaminant<br />
valve<br />
Warm out<br />
Cold in<br />
➄<br />
➅<br />
➁<br />
➂<br />
Chamber<br />
flush valve<br />
Nozzle<br />
Filter<br />
Type selection<br />
Three modules in different sizes are<br />
available to cover the most common<br />
requirement profiles (family home, multifamily<br />
house, commercial…).<br />
<strong>ThermoCYCLE</strong> ® 355<br />
Flow rate: up to 40 l/min (e.g. 3-5 showers simultaneously)<br />
<strong>ThermoCYCLE</strong> ® 450<br />
Flow rate: up to 80 l/min (e.g. 6-10 showers simultaneously)<br />
<strong>ThermoCYCLE</strong> ® 630<br />
Flow rate: up to 200 l/min (e.g. 11-25 showers simultaneously)<br />
It is also possible to use several modules in<br />
parallel depending on the size of the system.<br />
This information is based on experience and the exact sizing<br />
must be considered separately for each case.<br />
Perfect proportions<br />
<strong>ThermoCYCLE</strong> ® requires little space<br />
and can be easily transported<br />
through narrow staircases and small<br />
doors because of its slim dimensions.<br />
This makes it particularly suited<br />
to renovated older buildings.<br />
The modules can be combined with<br />
or supplemented using other residual<br />
heat systems.<br />
Your partner for <strong>Forstner</strong> heat storage technology:<br />
<strong>Forstner</strong> Grey Water Heat Recovery<br />
www.speichertechnik.com<br />
<strong>ThermoCYCLE</strong> ® -Modules are logical, simple and just better!<br />
Heat recovery system at the public Heat exchange using the cross<br />
bath in Dornbirn flow principle<br />
Heat Recovery Module<br />
Heat recovery from grey water is the efficient use of heat that flows<br />
irretrievably into the sewers without <strong>ThermoCYCLE</strong> ® .<br />
DISSIPATED HEAT AT YOUR DISPOS<br />
Should warm shower water get lost in the sewers?<br />
No. Expensive heat is used again to pre-heat service water<br />
and also for the heating system.<br />
We take regular showers...<br />
<strong>ThermoCYCLE</strong> ® allows the intelligent use of previously<br />
unused energy potential.<br />
Amortisation?<br />
Yes. It is possible to recover up to 50% and more<br />
energy input.<br />
On course of innovation -<br />
Our developments are always one step ahead
<strong>ThermoCYCLE</strong> ® - the heat recovery module www.speichertechnik.com<br />
<strong>ThermoCYCLE</strong> ® -<br />
integrates environmental<br />
protection in your life<br />
What means grey water?<br />
Grey water is wastewater from the bath, shower, washbasin and washing machine.<br />
It is created continuously in almost constant quantities – independently of the season or the weather.<br />
What means heat recovery?<br />
Everyone knows that good insulation keeps warmth<br />
inside a building. There are other sources of heat,<br />
besides room heat, that should not leave your building,<br />
namely the 28°C - 40°C warm wastewater from your<br />
shower, washbasin or washing machine … (grey<br />
water). Unfortunately this thermal potential discharges<br />
into the sewers all around the world.<br />
<strong>Forstner</strong> has developed the <strong>ThermoCYCLE</strong> ® heat<br />
recovery system in order to use this heat source efficiently.<br />
The highly efficient process of the patented<br />
<strong>ThermoCYCLE</strong> ® extracts valuable energy from the<br />
grey water as it flows off. Without seperate costs this<br />
heat is used indirectly to pre-heat service water<br />
and/or to support the heating system.<br />
Field of application<br />
The <strong>ThermoCYCLE</strong> ® system can be used everywhere<br />
where warm water flows off, as in a sports or leisure<br />
facility, a hotel, indoor swimming pool, cam ping<br />
site, retirement home, rehabilitation centre, familiy<br />
home or multi-family house.<br />
Litres per person per day<br />
Water consumption?<br />
Shower DOMESTIC<br />
Shower CAMPING<br />
Shower HOTEL/WELLNESS<br />
Toilet flushing<br />
Washing machine<br />
Personal hygiene<br />
Kitchen<br />
43 55 150 40 18 8 10<br />
The warmth from this wastewater can<br />
be used by <strong>ThermoCYCLE</strong> .<br />
®<br />
Wastewater that contains faeces,<br />
oil or fat may not be used.<br />
Conditions of installation<br />
In order to use grey water you need a wastewater<br />
pipe system that is separated from the black water<br />
(e.g. waste water from toilets or the kitchen). This is<br />
easy and inexpensive to realise in new buildings or<br />
in the course of general renovations.<br />
Cold<br />
service<br />
water<br />
Thermal energy (heat) is one of<br />
the basic requirements of<br />
mankind and is needed in all<br />
situations. It is not possible to<br />
create energy, only to convert or<br />
to save it.<br />
For this reasons it should be a<br />
primary aim to use our energy<br />
(heat) more carefully, at least if<br />
it is possible to make the decision<br />
ourselves.<br />
Considerable advantages:<br />
Very high savings potential<br />
Reduction of the emission of harmful substances<br />
An average of 15 kWh can be recovered from 1000<br />
litres of grey water (measured with cold water temperatures<br />
between 8-12°C).<br />
Simple technology<br />
Tested and patented procedure<br />
Made of high quality materials such as stainless steel<br />
1.4404 (V4A) and plastic (PE)<br />
<strong>ThermoCYCLE</strong> ® System – the ideal pre-heating stage when combined with the FORSTNER ® Hygienic Storage System<br />
Floor heating<br />
Heat<br />
production<br />
Warm grey water for heat recovery<br />
Flushing and<br />
regulation module<br />
Cooled grey water or contaminants feed<br />
into the sewer system.<br />
No moving component parts in the container<br />
Easy to install<br />
Uses a minimal amount of space (less than 2 m 2 )<br />
Manageable investment costs<br />
Best cost-benefit ratio<br />
Eligible for grants<br />
Sustainable, future-oriented system:<br />
The earth is only lent by<br />
from the next generation.<br />
Cold service water<br />
Warm service water from FORSTNER ®<br />
Cooled water to <strong>ThermoCYCLE</strong> ®<br />
Pre-heated water from <strong>ThermoCYCLE</strong> ®