<strong>Jones</strong> <strong>Stephens</strong> Corp. • PlumBest • LTConnections<br />

DESCRIPTION<br />

Closed Cell Pipe Insulation is a<br />

fl exible and easy-to-apply tubing<br />

product available in Semi-Slit and<br />

Self-Sealing styles. These chemically<br />

inert pipe insulations are specially<br />

formulated to retard heat gain and<br />

their closed-cell structures allow them<br />

to function as effi cient insulators. The<br />

Self-Sealing version has yellow selfseal<br />

release liner that is both easy to<br />

see and peel.<br />

APPLICATIONS<br />

To reduce unwanted heat loss or heat<br />

gain, control condensation, decrease<br />

plumbing noise and maximize<br />

energy savings. They can be used on<br />

hot and cold water lines, refrigeration<br />

lines, air conditioning lines; line<br />

set tubing, condenser coils, and connection<br />

and distribution lines.<br />

Closed Cell Pipe Insulation has low<br />

thermal conductivity and a very low<br />

water vapor transmission rate. This<br />

low density product demonstrates excellent<br />

thermal, physical and chemical<br />

resistant properties, and has a<br />

broad service temperature range<br />

between -90° F and 180° F (-68° C<br />

and 82° C). It can be installed in<br />

commercial, industrial, and residential<br />

insulation projects.<br />

CLOSED CELL<br />

Pipe Insulation<br />

INSTALLATION<br />

Closed Cell Pipe Insulation is installed<br />

by sliding the stick over pipe or tubing.<br />

For existing lines, the insulation<br />

should be slit lengthwise and fi tted<br />

over the pipe. When in place, make<br />

sure all seams are adhered with contact<br />

adhesive and pressed together to<br />

form a seal. The Self-Sealing version<br />

does not require adhesive. Fittings<br />

can be fabricated from miter-cut<br />

tubular sections. Closed Cell Pipe<br />

Insulation is easily cut with a sharp<br />

knife.<br />

OUTDOOR APPLICATIONS<br />

Outdoor applications require a protective<br />

coating (high quality exterior<br />

acrylic latex paint) for optimum<br />

performance. For best appearance,<br />

two coats are recommended.<br />

UNDERGROUND<br />

For buried lines above the water<br />

table, use a clean fi ll such as sand<br />

(3”-5” layer) to protect Closed Cell<br />

Pipe Insulation before backfi lling. It is<br />

recommended that all materials to<br />

be buried are properly sealed at all<br />

seams and butt joints with Contact<br />

Adhesive. For optimum performance,<br />

the lines should be encased in conduit<br />

to protect them from problems<br />

associated with ground water.<br />

RESISTANCE TO MOISTURE<br />

VAPOR FLOW<br />

The closed-cell structure effectively<br />

retards the fl ow of moisture vapor,<br />

and is considered a low transmittance<br />

vapor retarder. For most applications,<br />

Closed Cell Pipe Insulation<br />

needs no additional protection.<br />

Toll Free Phone 1-800-35-JONES (355-6637) • Toll Free Fax 1-800-462-6991 • Website www.plumbest.com<br />

Poly Insulation<br />

Additional vapor barrier protection<br />

may be necessary for Closed Cell<br />

Pipe Insulation when installed on low<br />

temperature surfaces or where it is<br />

exposed to continuous high humidity.<br />

FLAME AND SMOKE RATING<br />

Closed Cell Pipe Insulation in wall<br />

thicknesses of 1” (25mm) and below<br />

has a fl ame spread rating of 25 or<br />

less and a smoke development rating<br />

of 50 or less as tested by ASTM E<br />

84; CAN/ULC-S102.2-M88 Method<br />

of Testing entitled: “Surface Burning<br />

Characteristics of Building Materials.”<br />

Numerical fl ammability ratings alone<br />

may not defi ne the performance of<br />

products under actual fi re conditions.<br />

They are provided only for use<br />

in the selection of products to meet<br />

limits specifi ed, when compared to a<br />

known standard.<br />

SPECIFICATION COMPLIANCE<br />

Complies with requirements of:<br />

ASTM E 84; CAN/ULC S102.2<br />

ASTM D 1622<br />

ASTM D 1171<br />

ASTM C 177 or C518<br />

ASTM E 96<br />

C<br />