WHITE PAPER PERFORMANCE REPORT PRIMERGY RX300 S7 VERSION: 1.3 2012-10-09<br />

After the hard disks the RAID controller is the second performance-determining key component. In the case<br />

of these controllers the ―modular RAID‖ concept of the PRIMERGY servers offers a plethora of options to<br />

meet the various requirements of a wide range of different application scenarios.<br />

The following table summarizes the most important features of the available RAID controllers of the system.<br />

A short alias is specified here for each controller, which is used in the subsequent list of the performance<br />

values.<br />

Controller name Alias Cache Supported<br />

interfaces<br />

LSI SW RAID on Intel<br />

C600 (Onboard SATA)<br />

LSI SW RAID on Intel<br />

C600 (Onboard SAS)<br />

RAID Ctrl SAS 6G 0/1<br />

(D2607)<br />

RAID Ctrl SAS 6G 5/6 512<br />

MB (D2616)<br />

RAID Ctrl SAS 6G 5/6 1GB<br />

(D3116)<br />

Max. # disks<br />

in the system<br />

RAID levels BBU/<br />

FBU<br />

Patsburg A - SATA 3G - 4 × 2.5" 0, 1, 10 -/-<br />

Patsburg B - SATA 3G<br />

SAS 3G<br />

LSI2008 - SATA 3G/6G<br />

SAS 3G/6G<br />

LSI2108 512 MB SATA 3G/6G<br />

SAS 3G/6G<br />

LSI2208-1G 1 GB SATA 3G/6G<br />

SAS 3G/6G<br />

- 4 × 2.5" 0, 1, 10 -/-<br />

PCIe 2.0<br />

x8<br />

PCIe 2.0<br />

x8<br />

PCIe 2.0<br />

x8<br />

8 × 2.5"<br />

6 × 3.5"<br />

16 × 2.5"<br />

6 × 3.5"<br />

16 × 2.5"<br />

6 × 3.5"<br />

0, 1, 1E, 10 -/-<br />

0, 1, 5, 6, 10,<br />

50, 60<br />

0, 1, 1E, 5, 6,<br />

10, 50, 60<br />

The onboard RAID controller is implemented in the chipset Intel C600 on the motherboard of the server and<br />

uses the CPU of the server for the RAID functionality. This controller is a simple solution that does not<br />

require a PCIe slot. In addition to the invariably available connection option of SATA hard disks, the<br />

additional SAS functionality can be activated via an ―SAS enabling key‖.<br />

System-specific interfaces<br />

The interfaces of a controller to the motherboard and to the hard disks have in each case specific limits for<br />

data throughput. These limits are listed in the following table. The minimum of these two values is a definite<br />

limit, which cannot be exceeded. This value is highlighted in bold in the following table.<br />

Controller<br />

alias<br />

Effective in the configuration Connection<br />

# Disk<br />

channels<br />

Limit for<br />

throughput of<br />

disk interface<br />

PCIe<br />

version<br />

PCIe<br />

width<br />

Limit for<br />

throughput of<br />

PCIe interface<br />

via<br />

expander<br />

Patsburg A 4 × SATA 3G 973 MB/s - - - -<br />

Patsburg B 4 × SAS 3G 973 MB/s - - - -<br />

LSI2008 8 × SAS 6G 3890 MB/s 2.0 X8 3433 MB/s -<br />

LSI2108 8 × SAS 6G 3890 MB/s 2.0 X8 3433 MB/s <br />

LSI2208-1G 8 × SAS 6G 3890 MB/s 2.0 X8 3433 MB/s <br />

An expander makes it possible to connect more hard disks in a system than the SAS channels that the<br />

controller has. An expander cannot increase the possible maximum throughput of a controller, but makes it<br />

available in total to all connected hard disks.<br />

More details about the RAID controllers of the PRIMERGY systems are available in the white paper ―RAID<br />