05.04.2013 Views

MRD2 TENANT FITOUT DESIGN REVIEW - Westfield

MRD2 TENANT FITOUT DESIGN REVIEW - Westfield

MRD2 TENANT FITOUT DESIGN REVIEW - Westfield

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

UNIT NUMBER:<br />

RETAILER:<br />

Notes:<br />

STATUS DEFINITION<br />

A<br />

B<br />

C<br />

<strong>MRD2</strong> <strong>TENANT</strong> <strong>FITOUT</strong> <strong>DESIGN</strong> <strong>REVIEW</strong><br />

ZONE: RPM/RDM:<br />

LEVEL: <strong>REVIEW</strong>ER: Natalie Loveridge<br />

DATE RECEIVED REVISION DATE RETURNED CDD M&E SRUT<br />

A<br />

NOTE TO <strong>TENANT</strong><br />

CURRENT OVERALL<br />

STATUS<br />

To ensure prompt detailed design (RD2) approval, please fill in the grey FOR <strong>TENANT</strong> USE columns on the three following<br />

pages for the required outstanding information. Please return a copy with your revised detailed design submission.<br />

Status A signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted.<br />

Status B signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted subject to tenant taking necessary actions to incorporate the<br />

Landlords comments and annotations.<br />

Status C signifies that no work shall be fabricated manufactured or constructed. The tenant must submit new drawings to the landlord for review until resubmission is no longer<br />

required.


General Arrangement<br />

Shopfront<br />

Detail<br />

Life Safety<br />

Note<br />

Tenant Design Contact: Name:<br />

Email:<br />

Phone:<br />

UNIT NUMBER: 0 ZONE:<br />

0 RDM/RPM: 0 DATE <strong>REVIEW</strong>ED: 0<br />

RETAILER: 0 LEVEL: 0 <strong>REVIEW</strong>ER: Natalie Loveridge REVISION: A<br />

CHECKLIST<br />

Provide: GA Plan 1:50 scale for each level<br />

showing;<br />

All partitions with construction types, fire rating<br />

and fire doors<br />

Indication of Back of House ramps (if required)<br />

Provide: GA Section 1:50 scale cross and longitudinal<br />

Provide: Plans, sections, elevations and details of<br />

shopfront showing;<br />

Details of shopfront interfaces with landlord<br />

pilasters, bulkheads, walls, and floor at 1:10/1:5<br />

scale<br />

Glazing specification (if applicable)<br />

Provide: Details (where applicable) indicating;<br />

Tenant finishes over movement joint<br />

Any penetrations of landlords bulkhead (Level<br />

08 units)<br />

Provide: Sprinkler layout plan indicating;<br />

All areas of unit sprinklered including Back of<br />

House and store areas<br />

Underside of mezzanine sprinklered (If<br />

applicable)<br />

Provide: Indication of rear exit smoke lobby (if<br />

required) and means of escape<br />

Provide: Smoke curtain location and details (if<br />

required)<br />

Provide: Smoke fire stop and smoke containment<br />

details (if required)<br />

Provide: Indication of smoke extract grille in Front of<br />

House area (Level 08 units)<br />

Floor finishes zone: Ensure tenant floor build-up<br />

specification is in line with Tenant Floor Finishes<br />

Zone memo<br />

Other<br />

Other<br />

Other<br />

Other<br />

Other<br />

Other<br />

STATUS DEFINITION<br />

A<br />

B<br />

C<br />

<br />

Included<br />

<strong>MRD2</strong> CONSTRUCTION DETAIL <strong>DESIGN</strong> CHECKLIST<br />

Drawing number or<br />

document<br />

description<br />

Required for<br />

Approval<br />

(Y/N)<br />

Reviewed (A,<br />

B or C)<br />

COMMENTS<br />

Status A signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted.<br />

Included in<br />

revised<br />

submission<br />

<br />

OVERALL<br />

STATUS<br />

FOR <strong>TENANT</strong> USE<br />

Located on: (drawing<br />

number or document<br />

description)<br />

Status B signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted subject to tenant taking necessary actions to incorporate the Landlords<br />

comments and annotations.<br />

Status C signifies that no work shall be fabricated manufactured or constructed. The tenant must submit new drawings to the landlord for review until resubmission is no longer required.


Fire<br />

Electrical<br />

Mechanical<br />

Public Health<br />

Food (A3)<br />

Tenant M&E Contact: Name:<br />

Email:<br />

Phone:<br />

UNIT NUMBER: 0<br />

ZONE: 0 RDM/RPM: 0 DATE <strong>REVIEW</strong>ED: 0 OVERALL<br />

RETAILER: 0 LEVEL: 0 <strong>REVIEW</strong>ER: David Rasmussen/NDY REVISION: A<br />

STATUS<br />

UNIT AREA: SQM SQF UNIT TUP ALLOWANCE:<br />

0<br />

CHECKLIST<br />

Provide: Sprinkler layout & schematic drawings<br />

showing;<br />

Flow switch/zone check valve facility located<br />

inside tenancy<br />

System designed to BS EN 12845 and LPC<br />

requirements and installed by LPCB1048<br />

Accredited Contractor<br />

Sprinkler void protection provided<br />

Provide: Fire alarm layout & schematic showing;<br />

Fire panel location indicated<br />

Flashing beacon located at all rear entries of<br />

unit linked to tenant FIP<br />

Landlord and Tenant interface devices, including<br />

isolation of background music, mechanical<br />

systems etc.<br />

Automatic detection to L2+M (including voids)<br />

and sounders throughout<br />

Provide: Schematic electrical layout showing;<br />

Landlord interface (including fuse rating within<br />

switch-fuse and cable size to tenants board)<br />

Maximum Demand (provide load schedule if<br />

over TUP allowance)<br />

Provide: Schematic for heating and chilled water<br />

systems showing;<br />

Standard valving arrangement with 2-port<br />

control valves<br />

Flow rates not exceeding tenant allowance<br />

System pressure drops


Plan Layout<br />

Shopfront<br />

Vertical Transport<br />

New mezzanine<br />

/plant room floors<br />

Inter-tenancy<br />

Walls<br />

Tenant Structural Contact: Name:<br />

Email:<br />

Phone:<br />

UNIT NUMBER: 0 ZONE: 0 RDM/RPM: 0 DATE <strong>REVIEW</strong>ED: 0<br />

RETAILER:<br />

0 LEVEL: 0 <strong>REVIEW</strong>ER: Robert Vozila/MPN REVISION: A<br />

CHECKLIST<br />

All pits and penetrations dimensioned back to<br />

landlord grid<br />

Location and depth of any pockets or chases in<br />

floor slabs<br />

Set out of any items that have significant load<br />

and/or any items attached to landlord structure<br />

dimensioned back to landlord grid<br />

Provide: Reaction loads for;<br />

Any items that have significant load and/or any<br />

items attached to landlord structure<br />

dimensioned back to landlord grid<br />

Provide: Shopfront structural load calculations or<br />

certificate of glazing panels<br />

Plinth to spread escalator erection loads prior to<br />

installation<br />

STATUS DEFINITION<br />

A<br />

B<br />

C<br />

<br />

Included<br />

Provide: GA Plan at 1:50 scale for each floor showing,<br />

Provide: Plans (dimensioned back to landlord grid),<br />

sections, elevations and details of shopfront glazing<br />

Provide: Reaction loads of shopfront located on plan<br />

dimension back to landlord grid<br />

Provide: Additional secondary steel work<br />

Provide: Lift, stair and escalator details indicating;<br />

Weights, loads and calculations<br />

Provide: Method statement of escalator installation<br />

showing;<br />

Provide: Post and stair layout showing;<br />

Reaction loads on plan dimensioned back to<br />

landlord grid<br />

Provide: Lateral stability calculations<br />

Provide: Independent support details for;<br />

Any fixed shelving or furniture etc.<br />

NOTE: Fixing to landlord inter-tenancy walls is not<br />

permitted. Refer to guidelines in Tenant Fit-out<br />

Guide, Appendix 5, Item 2.<br />

Other<br />

Other<br />

Other<br />

Other<br />

Other<br />

<strong>MRD2</strong> STRUCTURAL <strong>DESIGN</strong> CHECKLIST<br />

Drawing number or<br />

document<br />

description<br />

Required for<br />

Approval<br />

(Y/N)<br />

Reviewed (A,<br />

B or C)<br />

COMMENTS<br />

Status A signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted.<br />

Included in<br />

revised<br />

submission<br />

<br />

OVERALL<br />

STATUS<br />

FOR <strong>TENANT</strong> USE<br />

Located on: (drawing<br />

number or document<br />

description)<br />

Status B signifies that fabrication, manufacture, or construction may proceed in accordance with drawing submitted subject to tenant taking necessary actions to incorporate the Landlords<br />

comments and annotations.<br />

Status C signifies that no work shall be fabricated manufactured or constructed. The tenant must submit new drawings to the landlord for review until resubmission is no longer required.