09.04.2013 Views

IEI Hub Manager Professional v8 - Linear

IEI Hub Manager Professional v8 - Linear

IEI Hub Manager Professional v8 - Linear

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

166<br />

Chapter 6: Database<br />

The Cancel button discards all edits and returns to Access Levels directory without<br />

saving data.<br />

User Types<br />

Com Unlock - Import \ Export (aka Communications Enable)<br />

This user type is supported by Handheld connected controllers only. It is used to<br />

unlock (or enable) infrared communications in the controller so you can export data to<br />

it from a Handheld device or import transaction logs. This user type does not unlock<br />

the door.<br />

Emergency<br />

As the name implies, this user type is designed for use in emergency situations. An<br />

Emergency User is a special user that unlocks the door regardless of reason it is<br />

locked. This user overrides a Lockout User, meaning if the controller is in lockout<br />

mode an Emergency user can still gain access. In battery powered products, with the<br />

low voltage warning and inhibit features, standard user's are denied access when the<br />

low voltage inhibit warning is reached (ie. low battery). However, Emergency Users<br />

can still gain access after this threshold is reached. One other important item to note<br />

is the unlock timer. This user type uses the Lock Timer - Extended Users time,<br />

rather than the time for Standard Users.<br />

NOTE: The Emergency User type cannot be disabled via the User directory or the<br />

User edit screen. If you do disable a user in the software, the user will still gain<br />

access. An Emergency User in the Max 3 v2 controller has 24 hour access,<br />

regardless of the Time Zones assigned in the Access Level. In addition, this user<br />

type will not trigger a First-In Auto-Unlock Time Zone.<br />

Extended Time<br />

An Extended Time user type unlocks the door for a longer period of time than a<br />

standard user. The unlock time is set in the Lock Timer - Extended Users setting in<br />

the System Parameters section of the Door edit screen. This time is defaulted to 10<br />

seconds. You must specify the time in each individual controller. You would use this<br />

user type for anyone that requires more time to get to the door after they've unlocked<br />

it.<br />

Lockout<br />

<strong>IEI</strong> <strong>Hub</strong> <strong>Manager</strong> <strong>Professional</strong> <strong>v8</strong>