The working principles ‘pressure’ and ‘vacuum’<br />

The sample determines<br />

the principle<br />

The <strong>ViscoSystem</strong> ® <strong>AVS</strong> 350 uses<br />

the traditional principle of<br />

pressure, i.e. the sample to be<br />

measured is pressed into the<br />

viscometer with an excess pressure<br />

of up to 0.1 bar.<br />

Comparisons between preferred applications<br />

<strong>ViscoSystem</strong> ® <strong>AVS</strong> 350 and <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360<br />

<strong>AVS</strong> 350 <strong>AVS</strong> 360<br />

Highly viscous samples e.g. oils and polymers yes yes<br />

Automatic cleaning of the<br />

capillary viscometer<br />

The <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360 unit<br />

can be combined with a<br />

semi-automatic suction unit<br />

which includes a suction pump<br />

6<br />

(VZ 5625) and the associated<br />

suction set (VZ 5624). The<br />

semi-automatic suction unit<br />

enables the viscometer to be<br />

emptied in the bath and to<br />

rinse it with the next sample.<br />

(up to approx. 3000 mm 2 /s) (above approx. 3000 mm 2 /s)<br />

Solvents: (examples) highly volatile yes no<br />

sulphuric acid no yes<br />

dichloroacetic acid no yes<br />

toluene yes yes<br />

acetone yes yes<br />

hexafluorisopropanol no yes<br />

m-cresol no yes<br />

Scanning of the opto-electronically* yes yes<br />

fluid meniscus TC sensors* yes yes<br />

PC connection (RS-232-C) exists exists<br />

Software WinVisco Stand alone station yes yes<br />

* with the appropriate viscometer<br />

The viscometer Visco-<br />

System ® <strong>AVS</strong> 360 has<br />

been developed for the<br />

improved measurement of<br />

highly viscous samples. It works<br />

with vacuum to suction the<br />

sample into the viscometer. The<br />

‘vacuum’ working principle<br />

provides the user with a greater<br />

degree of safety: the sample<br />

and up to 8 units<br />

cannot splash out of the viscometer<br />

and this means the<br />

user is not exposed to health<br />

risks from solvents.<br />

Due to the vacuum principle,<br />

the <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360<br />

makes it possible to achieve<br />

greater reproducibility of the<br />

measured values even when<br />

The sample which has already<br />

been measured is sucked into a<br />

waste bottle and hence the<br />

user no longer comes into contact<br />

with dangerous solvents. A<br />

further advantage of the semi-<br />

highly viscous samples are<br />

used. An additional advantage<br />

of the <strong>AVS</strong> 360 is that the uniform<br />

formation of the ‘suspended<br />

sphere level’ is guaranteed<br />

even for the minimum sample<br />

volumes required for Ubbelohde<br />

viscometers.<br />

automatic suction unit is that<br />

the viscometer no longer has<br />

be removed and cleaned separately.<br />

Technical specifications <strong>AVS</strong> 350 <strong>AVS</strong> 360<br />

Measurement range (time) up to 9999.99 s; resolution 0.01 s see <strong>AVS</strong> 350<br />

Measurement range (viscosity) 0.35 ... 1,800 mm 2 /s (cSt) 0.35 ... approx. 5,000 mm 2 /s (cSt)<br />

Tolerance of time measurement ± 0.01 % see <strong>AVS</strong> 350<br />

Display tolerance ± 1 Digit (0.01 s) see <strong>AVS</strong> 350<br />

Readout six figure LED display with<br />

floating decimal point, height = 14.2 mm;<br />

additional LED display for<br />

no. of measurements, height = 7.6 mm<br />

see <strong>AVS</strong> 350<br />

Pump pressure approx. 0.04...0.1 bar, automatically controlled approx. -0.01... -0.4 bar,<br />

automatically controlled<br />

Programmable temp. equilibration time 0 ... 20 min see <strong>AVS</strong> 350<br />

Programmable no. of measurements 1 ... 10 see <strong>AVS</strong> 350<br />

Rinsing unit connection viscometer cleaner <strong>AVS</strong> 26 upon request<br />

Data outputs two RS-232C interfaces see <strong>AVS</strong> 350<br />

Power supply 230 V~ 50 ... 60 Hz: power consumption 30 VA see <strong>AVS</strong> 350<br />

(115 V~ 50 ... 60 Hz specify when ordering)<br />

Ambient temperature 0 ... + 50 °C see <strong>AVS</strong> 350<br />

Casing shielded plastic/steel casing<br />

with chemically resistant two component<br />

coating, can be stacked<br />

see <strong>AVS</strong> 350<br />

Dimensions 225 x 155 x 395 mm (W x H x D) see <strong>AVS</strong> 350<br />

Weight approx. 5.2 kg see <strong>AVS</strong> 350<br />

WinVisco-Software Stand-alone station stand-alone station<br />

for Windows‚ 95 (or higher) or for multi-tasking with 2–8 units<br />

Capillary viscometer The following capillary viscometers manufactured by Schott can be used to<br />

(see separate catalogue ‘Capillary viscometers’) measure fluids without solid particles and with a viscosity between 0.35 – 10,000 mm2 /s:<br />

Ubbelohde viscometer in compliance with DIN and ASTM, micro Ubbelohde viscometer,<br />

Cannon-Fenske routine viscometer and Mikro-Ostwald viscometer.<br />

We reserve the right to make technical changes.<br />

<strong>ViscoSystem</strong> is a registered trademark of the SCHOTT group, Mainz, Germany<br />