The working principles ‘pressure’ and ‘vacuum’<br />
The sample determines<br />
the principle<br />
The <strong>ViscoSystem</strong> ® <strong>AVS</strong> 350 uses<br />
the traditional principle of<br />
pressure, i.e. the sample to be<br />
measured is pressed into the<br />
viscometer with an excess pressure<br />
of up to 0.1 bar.<br />
Comparisons between preferred applications<br />
<strong>ViscoSystem</strong> ® <strong>AVS</strong> 350 and <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360<br />
<strong>AVS</strong> 350 <strong>AVS</strong> 360<br />
Highly viscous samples e.g. oils and polymers yes yes<br />
Automatic cleaning of the<br />
capillary viscometer<br />
The <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360 unit<br />
can be combined with a<br />
semi-automatic suction unit<br />
which includes a suction pump<br />
6<br />
(VZ 5625) and the associated<br />
suction set (VZ 5624). The<br />
semi-automatic suction unit<br />
enables the viscometer to be<br />
emptied in the bath and to<br />
rinse it with the next sample.<br />
(up to approx. 3000 mm 2 /s) (above approx. 3000 mm 2 /s)<br />
Solvents: (examples) highly volatile yes no<br />
sulphuric acid no yes<br />
dichloroacetic acid no yes<br />
toluene yes yes<br />
acetone yes yes<br />
hexafluorisopropanol no yes<br />
m-cresol no yes<br />
Scanning of the opto-electronically* yes yes<br />
fluid meniscus TC sensors* yes yes<br />
PC connection (RS-232-C) exists exists<br />
Software WinVisco Stand alone station yes yes<br />
* with the appropriate viscometer<br />
The viscometer Visco-<br />
System ® <strong>AVS</strong> 360 has<br />
been developed for the<br />
improved measurement of<br />
highly viscous samples. It works<br />
with vacuum to suction the<br />
sample into the viscometer. The<br />
‘vacuum’ working principle<br />
provides the user with a greater<br />
degree of safety: the sample<br />
and up to 8 units<br />
cannot splash out of the viscometer<br />
and this means the<br />
user is not exposed to health<br />
risks from solvents.<br />
Due to the vacuum principle,<br />
the <strong>ViscoSystem</strong> ® <strong>AVS</strong> 360<br />
makes it possible to achieve<br />
greater reproducibility of the<br />
measured values even when<br />
The sample which has already<br />
been measured is sucked into a<br />
waste bottle and hence the<br />
user no longer comes into contact<br />
with dangerous solvents. A<br />
further advantage of the semi-<br />
highly viscous samples are<br />
used. An additional advantage<br />
of the <strong>AVS</strong> 360 is that the uniform<br />
formation of the ‘suspended<br />
sphere level’ is guaranteed<br />
even for the minimum sample<br />
volumes required for Ubbelohde<br />
viscometers.<br />
automatic suction unit is that<br />
the viscometer no longer has<br />
be removed and cleaned separately.<br />
Technical specifications <strong>AVS</strong> 350 <strong>AVS</strong> 360<br />
Measurement range (time) up to 9999.99 s; resolution 0.01 s see <strong>AVS</strong> 350<br />
Measurement range (viscosity) 0.35 ... 1,800 mm 2 /s (cSt) 0.35 ... approx. 5,000 mm 2 /s (cSt)<br />
Tolerance of time measurement ± 0.01 % see <strong>AVS</strong> 350<br />
Display tolerance ± 1 Digit (0.01 s) see <strong>AVS</strong> 350<br />
Readout six figure LED display with<br />
floating decimal point, height = 14.2 mm;<br />
additional LED display for<br />
no. of measurements, height = 7.6 mm<br />
see <strong>AVS</strong> 350<br />
Pump pressure approx. 0.04...0.1 bar, automatically controlled approx. -0.01... -0.4 bar,<br />
automatically controlled<br />
Programmable temp. equilibration time 0 ... 20 min see <strong>AVS</strong> 350<br />
Programmable no. of measurements 1 ... 10 see <strong>AVS</strong> 350<br />
Rinsing unit connection viscometer cleaner <strong>AVS</strong> 26 upon request<br />
Data outputs two RS-232C interfaces see <strong>AVS</strong> 350<br />
Power supply 230 V~ 50 ... 60 Hz: power consumption 30 VA see <strong>AVS</strong> 350<br />
(115 V~ 50 ... 60 Hz specify when ordering)<br />
Ambient temperature 0 ... + 50 °C see <strong>AVS</strong> 350<br />
Casing shielded plastic/steel casing<br />
with chemically resistant two component<br />
coating, can be stacked<br />
see <strong>AVS</strong> 350<br />
Dimensions 225 x 155 x 395 mm (W x H x D) see <strong>AVS</strong> 350<br />
Weight approx. 5.2 kg see <strong>AVS</strong> 350<br />
WinVisco-Software Stand-alone station stand-alone station<br />
for Windows‚ 95 (or higher) or for multi-tasking with 2–8 units<br />
Capillary viscometer The following capillary viscometers manufactured by Schott can be used to<br />
(see separate catalogue ‘Capillary viscometers’) measure fluids without solid particles and with a viscosity between 0.35 – 10,000 mm2 /s:<br />
Ubbelohde viscometer in compliance with DIN and ASTM, micro Ubbelohde viscometer,<br />
Cannon-Fenske routine viscometer and Mikro-Ostwald viscometer.<br />
We reserve the right to make technical changes.<br />
<strong>ViscoSystem</strong> is a registered trademark of the SCHOTT group, Mainz, Germany<br />