Fuel Cell Formulary - ZSW
Fuel Cell Formulary - ZSW
Fuel Cell Formulary - ZSW
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Just another<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong><br />
by Dr. Alexander Kabza<br />
This version is from February 27, 2012.
Contents 2<br />
Contents<br />
1 Fundmentals 4<br />
1.1 H2/O2 electrochemical device . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />
1.2 Reactant consumption and feed . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />
1.3 Energy content of hydrogen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />
1.4 <strong>Fuel</strong> cell stack power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />
1.5 <strong>Fuel</strong> cell stack efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
1.5.1 Different efficiencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />
1.5.2 Efficiency calculation example . . . . . . . . . . . . . . . . . . . . . . 12<br />
1.5.3 Electric efficiency calculation . . . . . . . . . . . . . . . . . . . . . . . 12<br />
1.6 Polarization curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />
2 <strong>Fuel</strong> cell system (FCS) 14<br />
2.1 Anode subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
2.2 Cathode subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />
2.3 Coolant subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />
2.4 FCS efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />
2.5 Example calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />
3 Appendix 1: Basics 19<br />
3.1 Thermodynamic basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />
3.2 Energy and relevant energy units . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />
3.3 Temperature dependency of thermodynamic values . . . . . . . . . . . . . . 20<br />
3.4 Standard temperature and pressure . . . . . . . . . . . . . . . . . . . . . . . 21<br />
3.5 HHV and LHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
3.6 Butler-Volmer equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />
4 Appendix 2: Constant values and abbreviations 25<br />
4.1 Relevant units based on SI units . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
4.2 Used abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />
5 Appendix 3: Air 27<br />
5.1 Moist air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />
5.2 Energy and power of air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />
5.3 Air compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
5.3.1 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />
5.3.2 Thermodynamics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />
5.3.3 Ideal and real compressor . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />
5.3.4 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />
5.3.5 Comment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
Contents 3<br />
6 Appendix 4: <strong>Fuel</strong> cell stack water management 42<br />
6.1 Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />
6.2 Derivation 1 (via volume flow and absolute humidity) . . . . . . . . . . . . . . 42<br />
6.3 Derivation 2 (via mass flow and specific humidity) . . . . . . . . . . . . . . . . 43<br />
6.4 Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1 Fundmentals<br />
This is a collection of relevant formulas, calculations and equations for designing a fuel cell<br />
system (FCS)<br />
1.1 H2/O2 electrochemical device<br />
In case of the hydrogen (H2) oxidation with oxygen (O2) the enthalpy ΔH is the enthalpy of<br />
water (H2O) formation and also known as the heating value of H2.<br />
In general, ΔH defines the chemical energy content; and ΔH is negative if energy is released<br />
by a chemical reaction (exothermal).<br />
Depending whether the product water is in either gaseous or liquid phase, there are two<br />
values for ΔH: The lower heating value (LHV) and the higher heating value (HHV). ΔH is a<br />
function of temperature and pressure; values at thermodynamic standard conditions (25 ◦ C<br />
and 101.325 kPa, see section 3.4) for LHV and HHV are defined as:<br />
H2 + 1<br />
2 O2 → H2O (g)<br />
H2 + 1<br />
2 O2 → H2O (l)<br />
ΔHH2O (g) = −LHV = −241.82 kJ/mol<br />
ΔHH2O (l) = −HHV = −285.83 kJ/mol<br />
Please note that LHV and HHV do have positive signs whereas ΔH is negative.<br />
The difference between LHV and HHV of 44.01 kJ/mol is equal to the molar latent heat of<br />
water vaporization.<br />
The free or Gibbs enthalpy G = H − TSdefines the energy which is available and can<br />
be extracted to do external work, neglecting any work done by changes in pressure and/or<br />
volume.<br />
The (thermodynamic) electromotive force (EMF) or reversible open cell voltage (OCV) E 0 of<br />
each electrochemical device is given by:<br />
E 0 = ΔG<br />
n · F<br />
where n is the amount of exchanged electrons and F is Faraday’s constant (see chapter 4).<br />
For hydrogen oxidation or water formation n =2.<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
4
1.1 H2/O2 electrochemical device 5<br />
The free enthalpies of water formation are:<br />
ΔGH2O (g) = −228.57 kJ/mol and ΔGH2O (l) = −237.13 kJ/mol<br />
therefore the reversible voltages are:<br />
E 0 g = −ΔGH2O (g)<br />
2F<br />
=1.184 V and E 0 l = −ΔGH2O (l)<br />
2F<br />
=1.229 V (1.1)<br />
Beside the fact that these voltages are the maximum voltages which can theoretically be<br />
extracted from the electrochemical reaction of H2 and O2, two other voltages are also important<br />
for efficiency calculation (see later on). If all the chemical energy of hydrogen (i.e. its<br />
heating value or enthalpy of water formation) were transformed into electric energy (which is<br />
obviously not the case), the following voltage equivalents would result:<br />
E 0 LHV<br />
LHV<br />
=<br />
2F =1.253 V and E0 HHV<br />
HHV = =1.481 V (1.2)<br />
2F<br />
Those two values are the voltage equivalent to the enthalpy ΔH, also called thermal cell<br />
voltage (see [1], page 27).<br />
All those thermodynamic values are a function of temperature. The temperature dependency<br />
(of absolute values) is as following:<br />
T [°C] 0 25 50 100 200 400 600 800 1000<br />
LHV [kJ/mol] 241.6 241.8 242.1 242.6 243.5 245.3 246.9 248.2 249.3<br />
HHV [kJ/mol] 286.6 285.8 285.0 283.4 280.0 265.8 242.3 218.8 195.3<br />
ΔG H2O (g) [kJ/mol] 229.7 228.6 227.5 225.2 220.4 210.3 199.7 188.7 177.5<br />
ΔG H2O (l) [kJ/mol] 241.3 237.1 233.1 225.2 210.0 199.0 230.4 267.1 308.3<br />
Enthalpy<br />
[kJ/mol]<br />
300<br />
290<br />
280<br />
270<br />
260<br />
250<br />
240<br />
230<br />
220<br />
210<br />
200<br />
Calculated with HSC Chemistry 6.21<br />
HHV<br />
LHV<br />
DG H2O(l)<br />
DG H2O(g)<br />
0 20 40 60 80 100 120 140 160 180 200<br />
T [°C]<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.2 Reactant consumption and feed 6<br />
1.2 Reactant consumption and feed<br />
The reactants H2 and O2 are consumed inside the fuel cell stack by the electrochemical<br />
reaction. Based on Faraday’s laws of electrolysis the molar flows ˙n are defined as following:<br />
˙nO2<br />
˙nH2<br />
= I · N<br />
4F<br />
= I · N<br />
2F<br />
1<br />
= · ˙nH2 [˙nO2<br />
2<br />
[˙nH2 ]=mol/sec (1.3)<br />
]=mol/sec<br />
I is the stack load (electric current, [I] =A), and N is the amount of single cells (cell count,<br />
[N] =−). 2 respectively 4 is the number of electrons transferred per H2 or O2 during the<br />
electrochemical reaction. F is the Faraday constant.<br />
The stoichiometry λ defines the ratio between reactant feed into the stack and reactant consumption<br />
in the stack. Due to stack design and water management issues the stoichiometry<br />
is always above one:<br />
λ =<br />
˙nfeed<br />
˙nconsumed<br />
> 1 [λ] =−<br />
The molar flows of reactants H2 and air into the fuel cell stack are defined by an anode and<br />
cathode stoichiometry λ:<br />
˙nH2, in =˙nH2 · λanode =<br />
˙nair, in = ˙nO2<br />
xO2<br />
I · N<br />
2F<br />
· λanode<br />
I · N<br />
· λcathode = · λcathode<br />
4F · xO2<br />
where xO2 is the oxygen content in air.<br />
The molar flows of unconverted (dry) reactants at the stack exhaust are given as:<br />
˙nH2, out =˙nH2, in − ˙nH2<br />
˙nair, out =˙nair, in − ˙nO2<br />
= I · N<br />
2F · (λanode − 1)<br />
I · N<br />
=<br />
4F ·<br />
<br />
λcathode<br />
− 1<br />
xO2<br />
It is very common to give the reactant feed either as a mass or volume flow. The mass flow<br />
˙m is the product of molar flow ˙n and molar weight M:<br />
˙m =˙n · M [˙m] =g/sec or kg/h<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.3 Energy content of hydrogen 7<br />
The volume flow ˙ V is calculated by the gas density ρ or the molar gas volume V0, mol:<br />
˙V = ˙m<br />
ρ = V0, mol · ˙n [ ˙ V ]=l/min or m 3 /h<br />
Both the gas density ρ and the molar gas volume V0, mol are temperature and pressure dependent!<br />
Therefor the referring temperature and pressure need to be defined. A letter N<br />
or n indicates that the volume flow is normalized to a specific reference temperature and<br />
pressure (e.g. [ ˙ V ]=Nl/min or ln/min). For more information see section 3.4.<br />
1.3 Energy content of hydrogen<br />
Hydrogen contains chemical energy; and the amount of chemical energy is given by the HHV<br />
(or sometimes LHV) of H2. The mass specific chemical energy of H2 is therefore:<br />
WH2, HHV = HHV<br />
M<br />
= 285.83 kJ/mol<br />
2.02 g/mol<br />
WH2, LHV = 119.96 kJ/g<br />
= 141.79 kJ/g<br />
The volume specific chemical energy of H2 (at 273.15 K and 101.325 kPa) is:<br />
WH2, HHV = HHV<br />
V0,mol<br />
The chemical power of an H2 flow is:<br />
= 285.83 kJ/mol<br />
22.414 ln/mol =12.75 J/mln =12.75 kJ/m 3 n =3.54 kWh/m3 n<br />
WH2, LHV =10.79 J/mln =10.79 kJ/m 3 n =3.00 kWh/m3 n<br />
PH2, HHV = HHV · ˙nH2<br />
[PH2, HHV] =J/sec = W<br />
With equations 1.2 and 1.3, the chemical power H2 consumed in a stack with N cells at the<br />
stack load I can be expressed as:<br />
1.4 <strong>Fuel</strong> cell stack power<br />
PH2, HHV =1.481 V · N · I<br />
Electric stack power Pel is the product of stack voltage and stack load:<br />
Pel = UStack · I =Ave<strong>Cell</strong>· N · I<br />
where Ave<strong>Cell</strong> = UStack/N is the average single cell voltage ([Ave<strong>Cell</strong>] = V).<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.5 <strong>Fuel</strong> cell stack efficiency 8<br />
Thermal stack power Ptherm is the rest of the chemical power PH2, HHV of the consumed<br />
fuel (hydrogen) which is not converted into electric power:<br />
Ptherm = PH2, HHV − Pel<br />
For the hydrogen fuel cell it is defined based on HHV as:<br />
Ptherm, HHV =(1.481 V − Ave<strong>Cell</strong>) · N · I = Pel<br />
<br />
1.481 V<br />
− 1<br />
Ave<strong>Cell</strong><br />
1.481 V is the voltage equivalent of the HHV according to equation 1.2. To calculate the<br />
thermal power based on LHV this voltage equivalent needs to be replaced by 1.253 V.<br />
(1.4)<br />
Recoverable heat The recoverable heat is the part of the thermal stack power that is<br />
converted into usable heat. This is e.g. the heat transferred into the (liquid) coolant and can<br />
be calculated as following:<br />
Precoverable heat = ˙ V · cp · ΔT · ρ<br />
Coolant parameters are: ˙ V is the volume flow, cp is the heat capacity, ΔT is the temperature<br />
increase and ρ is the density.<br />
It is a fact that not all thermal power can be transferred to coolant; therefore:<br />
The rest is wasted heat:<br />
This waste heat consists of two parts:<br />
Precoverable heat
1.5 <strong>Fuel</strong> cell stack efficiency 9<br />
All efficiencies can be based on either LHV or HHV of the fuel. Is it true that in the U.S. HHV<br />
is used, whereas LHV is common practice in Europe? I don’t know.<br />
In general the efficiency η is defined as:<br />
η =<br />
(useful) energy output<br />
energy input<br />
= (useful) power output<br />
power input<br />
Maximum efficiency The maximum (thermodynamic and ideal) efficiency is the relation<br />
between the enthalpy (heating value) ΔH and the (maximum extractable) Gibbs free enthalpy<br />
ΔG of the electrochemical device:<br />
For the hydrogen cell it is:<br />
ηel, max, LHV = −ΔGH2O (g)<br />
LHV<br />
ηel, max, HHV = −ΔGH2O (l)<br />
HHV<br />
ηel, max = ΔG<br />
ΔH<br />
= E0 g<br />
E 0 LHV<br />
= E0 l<br />
E 0 HHV<br />
= 1.184 V<br />
= 1.229 V<br />
1.253 V =94.5%<br />
1.481 V =83.1%<br />
The Handbook of <strong>Fuel</strong> <strong>Cell</strong>s [1] calls this simply “ideal efficiency”.<br />
The <strong>Fuel</strong> <strong>Cell</strong> Handbook [2] calls this efficiency the “thermal efficiency of an ideal fuel cell<br />
operating reversibly on pure hydrogen and oxygen at standard conditions”.<br />
<strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3] calls this efficiency “the maximum efficiency possible” or<br />
“maximum efficiency limit” which explains it also very well.<br />
Electric efficiency The (thermodynamic) electric efficiency of a fuel cell (stack) is defined<br />
as:<br />
ηel =<br />
Pel<br />
Pfuel, consumed<br />
It can be defines on both LHV and HHV. Due to the fact that for hydrogen the HHV is 18.2%<br />
higher than LHV, the efficiency based on HHV is 18.2% lower than based on LHV.<br />
The electric efficiency is defined as (more details see section 1.5.3):<br />
Pel<br />
ηel, LHV =<br />
Pfuel, consumed<br />
= Ave<strong>Cell</strong><br />
1.253 V<br />
How this efficiency is named in literature and codes & standards:<br />
and ηel, HHV = Ave<strong>Cell</strong><br />
1.481 V<br />
(1.5)<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.5 <strong>Fuel</strong> cell stack efficiency 10<br />
1. “Load efficiency” in the Handbook of <strong>Fuel</strong> <strong>Cell</strong>s [1], refers to both LHV and HHV.<br />
2. The <strong>Fuel</strong> <strong>Cell</strong> handbook [2] refers to HHV and says “this efficiency is also referred to<br />
as the voltage efficiency”.<br />
3. “<strong>Cell</strong> efficiency” in <strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3], and refers to LHV.<br />
4. SAE J2617 [4] calls this efficiency “stack sub-system efficiency” and refers to LHV.<br />
<strong>Fuel</strong> electric efficiency The fuel efficiency considers the amount of hydrogen feed to the<br />
stack (and not only the amount of consumed hydrogen). It is defined as:<br />
Based on LHV or HHV this is:<br />
Pel<br />
ηfuel, el, LHV =<br />
Pfuel, feed<br />
Ave<strong>Cell</strong><br />
=<br />
1.253 V · λanode<br />
Pel<br />
ηfuel, el =<br />
Pfuel, feed<br />
and ηfuel, el, HHV =<br />
Obviously, the relation between ηfuel, el and ηel is the anode stoic:<br />
How this efficiency is named in literature:<br />
ηfuel, el = ηel<br />
λanode<br />
Ave<strong>Cell</strong><br />
1.481 V · λanode<br />
1. <strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3] calls this efficiency simply “efficiency” (of either LHV<br />
or HHV).<br />
2. <strong>Fuel</strong> <strong>Cell</strong> Handbook [2] says: “To arrive at the net cell efficiency, the voltage efficiency<br />
must be multiplied by the fuel utilization.” In my opinion it is not correct to call this<br />
efficiency voltage efficiency (see next paragraph).<br />
Voltage efficiency is the ratio between average and reversible cell voltage E 0 (equation<br />
1.1):<br />
ηvoltage = Ave<strong>Cell</strong><br />
E 0<br />
Normally the voltage efficiency is based on ΔGH2O (l) :<br />
ηvoltage = Ave<strong>Cell</strong><br />
E 0 l<br />
= Ave<strong>Cell</strong><br />
1.229 V<br />
ηvoltage = ηel, HHV · ηel, max, HHV = Ave<strong>Cell</strong><br />
· 0.831<br />
1.481 V<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.5 <strong>Fuel</strong> cell stack efficiency 11<br />
Thermal efficiency ηtherm can be calculated according the electric efficiency:<br />
Based on HHV it is:<br />
ηtherm =<br />
ηtherm, HHV =<br />
Ptherm<br />
Pfuel, consumed<br />
1.481 V − Ave<strong>Cell</strong><br />
1.481 V<br />
Recovered heat efficiency Due to the fact that not all thermal power P therm is transferred<br />
into the coolant the recovery heat efficiency can be calculated:<br />
For HHV this is:<br />
ηrecovered heat = Precovered heat<br />
Ptherm<br />
ηrecovered heat, HHV = Precovered heat<br />
Ptherm, HHV<br />
Overall stack efficiency can be calculated as:<br />
=<br />
ηoverall = Pel + Ptherm<br />
Pfuel, consumed<br />
˙V · cp · ΔT · ρ<br />
(1.481 V − Ave<strong>Cell</strong>) · N · I<br />
This (thermodynamic) efficiency needs to be ηoverall =1, because the consumed hydrogen<br />
is converted completely in electric and thermal power:<br />
Therefore it is also:<br />
=1<br />
Pfuel, consumed = Pel + Ptherm<br />
ηoverall = ηel + ηtherm<br />
Total efficiency is maybe more reasonable and defined as:<br />
ηtotal = Pel + Precoverable heat<br />
Pfuel, feed<br />
Now obviously ηtotal < 1, because Precoverable heat Pfuel, consumed!<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
< 1
1.5 <strong>Fuel</strong> cell stack efficiency 12<br />
1.5.2 Efficiency calculation example<br />
A fuel cell stack produces 10 kW electric power and consumes 150 ln/min H2. The stack<br />
runs at 600mV average cell voltage.<br />
What is the electric efficiency, the fuel efficiency and what is the anode stoichiometry?<br />
˙n =<br />
ηfuel, el, LHV =<br />
ηel, LHV = Ave<strong>Cell</strong><br />
E 0 LHV<br />
150 ln/min<br />
22.414 ln/mol · 60 sec/min<br />
Pel<br />
=<br />
˙nH2 · LHV<br />
λanode = ηel, LHV<br />
ηfuel, el, LHV<br />
1.5.3 Electric efficiency calculation<br />
How to come from ηel, LHV =<br />
With equations 1.2 and 1.3 it is:<br />
Pel<br />
ηel, LHV =<br />
Pfuel, consumed<br />
Pel<br />
Pfuel, consumed<br />
= 0.6V<br />
1.253 V =47.9%<br />
=0.1115 mol/sec<br />
10 kJ/sec<br />
0.1115 mol/sec · 241.82 kJ/mol =37.1%<br />
to Ave<strong>Cell</strong><br />
1.253 V ?<br />
= 47.9%<br />
37.1% =1.29<br />
= Ave<strong>Cell</strong> · N · I Ave<strong>Cell</strong> · 2F<br />
=<br />
˙nH2 · LHV LHV<br />
= Ave<strong>Cell</strong><br />
E 0 LHV<br />
= Ave<strong>Cell</strong><br />
1.253 V<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
1.6 Polarization curve 13<br />
1.6 Polarization curve<br />
The polarization curve or current voltage characteristic (U-I-curve) plots the cell voltage versus<br />
current density of a single cell (or stack). The following chart shows an pol curve example,<br />
including the electric and thermal power based on LHV or HHV (equation 1.4), and the<br />
electric efficiency based on LHV (1.5).<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
2 <strong>Fuel</strong> cell system (FCS)<br />
IEC 62282-1:2005 [5] defines the main components of a fuel cell system and draws the<br />
system boundary around:<br />
Power inputs<br />
Electrical<br />
thermal<br />
Air<br />
Ventilation<br />
Inert gas<br />
Water<br />
<strong>Fuel</strong><br />
EMD,<br />
vibration,<br />
wind, rain,<br />
temperature, etc.<br />
<strong>Fuel</strong><br />
Processing<br />
System<br />
Air<br />
Processing<br />
System<br />
Ventilation<br />
System<br />
Thermal<br />
Management<br />
System<br />
<strong>Fuel</strong> <strong>Cell</strong><br />
Module (Stack)<br />
Water<br />
Treatment<br />
System<br />
Automatic<br />
Control<br />
System<br />
Power<br />
Conditioning<br />
System<br />
Internal power<br />
needs<br />
Onboard<br />
Energy<br />
storage<br />
Recovered<br />
heat<br />
Waste heat<br />
Usable power<br />
Electrical (net)<br />
Discharge<br />
water<br />
Exhaust gases,<br />
ventilation<br />
EMI, noise,<br />
vibration<br />
The main components are the fuel cell stack, an air processing system (e. g. a compressor<br />
and humidifier), the fuel gas supply, thermal management system etc. Other peripheral components<br />
are valves, pumps, electrical devices etc. <strong>Fuel</strong> like hydrogen (from a tank system)<br />
and air (ambient) are feed into the FCS.<br />
Main FCS inputs are fuel (e.g. hydrogen), air and water, but also electric and thermal power.<br />
Main FCS outputs are the electric net and thermal power, the reactant exhaust gases and<br />
product water. The (electric) gross power is the stack electric power. The difference between<br />
gross and net is the electric power consumed by the parasitic electric components inside the<br />
FCS:<br />
Pnet = Pgross − Pparasitic<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
14
2.1 Anode subsystem 15<br />
2.1 Anode subsystem<br />
Hydrogen is feed into the fuel cell system from a tank system. The consumed hydrogen<br />
inside the fuel cell stack is based of the Faraday equation (equation 1.3) and depending on<br />
the stack load. Actually always more hydrogen is feed into the FCS than is consumed inside<br />
the stack. The relation between hydrogen feed versus consumed hydrogen is called FCS<br />
fuel stoichiometry:<br />
λfuel =<br />
fuel feed<br />
fuel consumed =<br />
H2 feed<br />
≥ 1<br />
H2 consumed<br />
The fuel efficiency (equal to fuel utilization) of a FCS is defined as:<br />
ηfuel =1/λfuel<br />
For many reasons a specific amount of anode off gas needs to exit the fuel cell stack. This<br />
stack anode off gas is finally purged either into the cathode exhaust or directly out of the<br />
FCS. This purged hydrogen is obviously lost for the electrochemical conversion.<br />
It needs to be distinguished between the stack anode and the FCS fuel stoichiometry. For<br />
fuel efficiency reasons the FCS fuel stoichiometry shall be close to 1. But the stack anode<br />
stoichiometry is in the range of 1.1 or 1.6, depending on the stack design and load. This can<br />
be realized e.g. by an anode recirculation system within the anode subsystem.<br />
2.2 Cathode subsystem<br />
An air processing system or cathode submodule is e.g. a compressor and a gas-to-gas<br />
humidifier. Its purpose is to feed the conditioned (humidified) and required amount of air into<br />
the stack.<br />
Ambient air has a specific relative humidity. Depending on the FCS design, this water input<br />
into the FCS may be neglected. More important is the pressure drop inside the stack and<br />
inside the FCS, and therefore the absolute pressure after the compressor and before the<br />
stack. The cathode stoichiometry is depending on the system power level; typical values are<br />
between 1.8 (at higher load) to 3 (or more at low load).<br />
Relative humidity at cathode exhaust In case of PEMFC stacks nearly all product water<br />
is removed via cathode exhaust, mainly as vapor. Assuming complete removal via cathode<br />
exhaust and no water input from ambient air, there is a quite simple relation between cathode<br />
stoichiometry, temperature and pressure of cathode exhaust (for more details see chapter<br />
6).<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
2.3 Coolant subsystem 16<br />
The following equation can be used to estimate the RH at the cathode exhaust at given outlet<br />
pressure pcathode out and temperature T and cathode stoichiometry λcathode:<br />
ϕ =<br />
1<br />
2 · pws(T ) ·<br />
pcathode out<br />
<br />
1+ λcathode<br />
xO 2<br />
where pws(T ) is the saturated water vapor pressure at the cathode outlet temperature T , and<br />
xO2 is the (molar) fraction of O2 in air. The complete derivation of this formula is explained in<br />
chapter 6.<br />
Enthalpy of wet cathode air exhaust The typically fully humidified cathode exhaust gas<br />
of a FCS contains a lot of energy in form of enthalpy (see also section 5.2).<br />
The increasing enthalpy of process air inside the FCS cathode subsystem considers first the<br />
temperature increase (from cold inlet to warm outlet) and second the product water uptake.<br />
As a fist guess the energy loss via stack (not FCS!) cathode exhaust seems to be the difference<br />
between thermal power based on HHV and LHV. But in fact this energy loss is even<br />
higher! This is due to the fact that the air temperature increases inside the stack, while LHV<br />
and HHV are based on the thermodynamic standard temperature T c.<br />
2.3 Coolant subsystem<br />
Coolant (typically liquid, e.g. DI water or WEG) is feed by the coolant pump into the fuel cell<br />
stack. Other peripheral components (e.g. electric converters, compressor, etc.) inside the<br />
FCS may also be cooled in parallel to the stack or serial before or after the stack.<br />
The coolant enters the stack at the stack inlet temperature and leaves the stack at the stack<br />
outlet temperature; leading to a specific temperature increase ΔT depending on stack load.<br />
Typical the temperature increase is ΔT ≤ 10 K. According to given ΔT requirements depending<br />
on stack load the coolant flow needs to be a function of the stack load, too.<br />
The required coolant flow rate ˙ V at a given stack recoverable heat Precoverable heat and coolant<br />
ΔT is calculated as following:<br />
˙V = Precoverable heat<br />
cp · ΔT · ρ<br />
<br />
[ ˙ V ]=l/min<br />
where cp is the specific heat capacity, ΔT = Tcool, out − Tcool, in and ρ the coolant density.<br />
The following table shows the specific heat capacity cp and density ρ of WEG at different<br />
temperatures and mixing ratios (vol%):<br />
Temp.<br />
0°C 20°C 40°C 60°C<br />
80°C<br />
ratio<br />
cp kJ/kg K<br />
ρ<br />
g/cm³<br />
cp<br />
kJ/kg K<br />
ρ<br />
g/cm³<br />
cp<br />
kJ/kg K<br />
ρ<br />
g/cm³<br />
cp<br />
kJ/kg K<br />
ρ<br />
g/cm³<br />
cp<br />
kJ/kg K<br />
ρ<br />
g/cm³<br />
0% 4.218 0.9998 4.182 0.9982 4.179 0.9922 4.184 0.9832 4.196 0.9718<br />
10% 4.09 1.018 4.10 1.011 4.12 1.002 4.13 0.993 4.15 0.983<br />
30% 3.68 1053 3.72 1044 3.76 1034 3.80 1023 3.84 1010<br />
50% 3.28 1.086 3.34 1.075 3.40 1.063 3.46 1.050 3.53 1.036<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
2.4 FCS efficiency 17<br />
Comment: 0% is pure water.<br />
This means that the required coolant volume flow for WEG (50vol%, 60 ◦ C) needs to be 12%<br />
higher compared to pure DI water.<br />
2.4 FCS efficiency<br />
The (electric) efficiency of a fuel cell system is defined as:<br />
ηFCS el =<br />
power out<br />
power in<br />
= electric net power out<br />
fuel power in<br />
= Pnet<br />
Pfuel<br />
“<strong>Fuel</strong> power” Pfuel is the product of the fuel (chemical) energy content based on HHV (or<br />
sometimes LHV) and the fuel feed. For hydrogen as fuel this “fuel power in” is defined as:<br />
Pfuel = HHV · ˙nH2<br />
FCS efficiency can also be exprssed as the product of different (system related) efficiencies<br />
(see also [1], page 718):<br />
with<br />
ηFCS el = ηstack · ηfuel · ηparasitic<br />
ηstack = Ave<strong>Cell</strong><br />
1.253 V , ηfuel = 1<br />
λfuel<br />
and ηparasitic = Pnet<br />
Pgross<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
2.5 Example calculation 18<br />
2.5 Example calculation<br />
Virtual H2/air fuel cell stack with 200 cells and 300 cm 2 active area:<br />
Current density * A/cm2 0.05<br />
Stack electric<br />
0.10 0.20 0.40 0.60 1.00<br />
Ave cell voltage * mV 839 797 756 703 661 588<br />
Current (gross) A 15 30 60 120 180 300<br />
Voltage V 168 159 151 141 132 118<br />
Power (gross) kW el 3 5 9 17 24 35<br />
Stoichiometry * - 3.0<br />
Stack anode<br />
2.0 1.3 1.3 1.3 1.3<br />
Hydrogen flow Nl/min 62.7 83.6 108.7 217.4 326.2 543.6<br />
Hydrogen flow g/sec 0.09 0.13 0.16 0.33 0.49 0.81<br />
Stoichiometry * - 2.2<br />
Stack cathode in<br />
2.0 1.8 1.8 1.8 1.8<br />
Air flow Nl/min 109.5 199.1 358.4 716.8 1075.2 1792.1<br />
Air flow g/sec 2.4 4.3 7.7 15.4 23.2 38.6<br />
Air flow kg/h 8.5 15.4 27.8 55.6 83.4 138.9<br />
P therm LHV kW 1.2 2.7 6.0 13.2 21.3 39.9<br />
P therm HHV kW 1.9 4.1 8.7 18.7 29.5 53.6<br />
delta HHV - LHV kW 0.7 1.4 2.7 5.5 8.2 13.7<br />
Coolant inlet temp * °C 60 60 60 60 60 60<br />
Coolant outlet temp * °C 61 63 66 67 68 70<br />
Coolant delta T K 1 3 6 7 8 10<br />
Coolant flow LHV 2<br />
l/min 17.9 13.1 14.3 27.1 38.3 57.4<br />
Coolant flow HHV 2<br />
Stack thermal<br />
l/min 27.7 19.7 20.8 38.3 53.1 77.0<br />
RH * % 100%<br />
Stack cathode out<br />
100% 100% 100% 100% 100%<br />
pws at coolant outlet temp kPa abs 20.84 22.83 26.12 27.30 28.52 31.12<br />
Pressure out kPa abs 120 120 125 131 137 149<br />
Product water out g/sec 0.3 0.6 1.1 2.2 3.4 5.6<br />
Consumed oxygen g/sec 0.2 0.5 1.0 2.0 3.0 5.0<br />
Dry cathode out g/sec 2 4 7 13 20 34<br />
Wet cathode out g/sec 2 4 8 16 24 39<br />
Enthalpy out kJ/kg 405 445 497 499 500 503<br />
P enthalpy out kW 1 2 3 7 10 17<br />
Stack power in (hydrogen)<br />
Hydrogen feed mol/sec 0.05 0.06 0.08 0.16 0.24 0.40<br />
P chem H2 LHV kW 11 15 20 39 59 98<br />
P chem H2 HHV kW 13 18 23 46 69 116<br />
Stack efficiency (LHV)<br />
Electric efficiency % 67% 64% 60% 56% 53% 47%<br />
<strong>Fuel</strong> efficiency % 22% 32% 46% 43% 41% 36%<br />
* given values<br />
1 20°C and 50% compressor efficiency<br />
2 WEG 50vol% at 60°C<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
3 Appendix 1: Basics<br />
3.1 Thermodynamic basics<br />
The four thermodynamic potentials are:<br />
Internal energy U is the total energy of an thermodynamic system and the sum of all forms<br />
of energies. In an isolated system the internal energy is constant and can not change.<br />
As one result of the first law or thermodynamics the change in the inner energy can be<br />
expressed as the heat supplied to the system minus the work performed by the system:<br />
dU =dq +dw<br />
Free or Helmholtz energy F (or A): is the ”useful” work obtainable from a thermodynamic<br />
system at isothermal and isobaric conditions.<br />
Enthalpy H: The enthalpy is a measure for the energy of a thermodynamic system and the<br />
sum of internal energy and the work for changing the volume: H = U + pV . For each<br />
chemical reaction the entropy change defines the reaction to be endothermic (ΔH 0).<br />
Free or Gibbs enthalpy G: The Gibbs or thermodynamic free enthalpy is the work that a<br />
thermodynamic system can perform: G = H − TS. For each chemical reaction ΔG<br />
defines the reaction to be exergonic (ΔG
3.2 Energy and relevant energy units 20<br />
The following total differentials of the four thermodynamic potentials can be determined:<br />
dU = −pdV + TdS dH = Vdp+ TdS dA = −SdT − pdV dG = Vdp− SdT<br />
How to determine the Maxwell relations?<br />
1. Select two units in the edge of one border, e.g. T and V .<br />
2. Select the corresponding units in the opposite border, here it is −p and −S.<br />
3. Now the Maxwell relation is here: ∂T/∂V = −∂p/∂S<br />
The following four Maxwell relations can be determined:<br />
(∂T/∂V )S = −(∂p/∂S)V<br />
(∂T/∂p)S =(∂V/∂S)p<br />
(∂p/∂T)V =(∂S/∂V )T<br />
(∂V/∂T)p = −(∂S/∂p)T<br />
And finally the following dependencies can be determined by the Guggenheim square:<br />
(∂U/∂S)V = T and (∂U/∂V )S = −p<br />
(∂H/∂S)p = T and (∂H/∂p)S = V<br />
(∂A/∂V )T = −p and (∂A/∂T)V = −S<br />
(∂G/∂p)T = V and (∂G/∂T )p = −S<br />
3.2 Energy and relevant energy units<br />
Energy is the product of power and time: E = P · t<br />
Units for energy:<br />
Joules and kilowatt-hour:<br />
[E]=J=kgm 2 /s 2 =Nm=Ws<br />
1 kWh = 1000 Wh ≡ 3.600.000 Ws = 3.600.000 J = 3.600 kJ = 3.6 MJ<br />
3.3 Temperature dependency of thermodynamic values<br />
Heat capacity of air cp, air of air as a function of temperature ( ◦ C):<br />
T 0 25 50 100 150 200 250 300 350 400 450 500<br />
cp [J/molK] 29.06 29.10 29.13 29.25 29.43 29.67 29.95 30.25 30.58 30.93 31.29 31.64<br />
cp [J/kgK] 1003.37 1004.56 1005.86 1009.91 1016.23 1024.43 1033.96 1044.49 1055.84 1067.87 1080.19 1092.28<br />
Calculated with HSC Chemistry 6.21, air with 78 Vol% N2, 21% O2 and 1% Ar<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
3.4 Standard temperature and pressure 21<br />
Heat capacity of other gases cp of different gases as a function of temperature ( ◦ C):<br />
Molar heat capacity cp [J/molK] vs t [°C]<br />
Species 0 25 50 100 150 200 250 300 350 400 450 500<br />
N2(g) 29.12 29.13 29.14 29.19 29.30 29.47 29.69 29.95 30.24 30.57 30.91 31.26<br />
O2(g) 29.26 29.38 29.50 29.87 30.33 30.83 31.33 31.83 32.31 32.76 33.18 33.56<br />
H2(g) 28.47 29.05 28.90 28.75 28.72 28.77 28.86 28.99 29.13 29.29 29.46 29.64<br />
CO2(g) 36.04 37.12 38.31 40.39 42.19 43.81 45.27 46.61 47.84 48.97 50.01 50.97<br />
H2O(g) 33.56 33.60 33.71 34.04 34.47 34.97 35.50 36.07 36.65 37.25 37.86 38.48<br />
Specific heat capacity cp [J/kgK] vs t [°C]<br />
Species 0 25 50 100 150 200 250 300 350 400 450 500<br />
N2(g) 1039.3 1039.7 1040.3 1042.1 1046.1 1052.2 1060.0 1069.2 1079.6 1091.2 1103.5 1115.9<br />
O2(g) 914.4 918.2 922.0 933.6 947.9 963.4 979.2 994.7 1009.6 1023.7 1036.8 1048.6<br />
H2(g) 14123.8 14409.3 14334.9 14260.3 14247.5 14271.3 14318.2 14380.1 14452.2 14531.3 14615.2 14702.6<br />
CO2(g) 818.9 843.5 870.4 917.7 958.7 995.4 1028.7 1059.1 1087.1 1112.8 1136.4 1158.0<br />
H2O(g) 1863.1 1865.3 1871.0 1889.3 1913.3 1940.9 1970.7 2002.1 2034.6 2067.9 2101.8 2136.2<br />
cp [JJ/mol<br />
K]<br />
50<br />
45<br />
40<br />
35<br />
30<br />
25<br />
20<br />
Calculated with HSC Chemistry 6.21<br />
CO2(g)<br />
H2O(g)<br />
O2(g)<br />
N2(g)<br />
H2(g)<br />
0 50 100<br />
T [°C]<br />
150 200<br />
3.4 Standard temperature and pressure<br />
Standard temperature and pressure (STP) is needed for many fuel cell related calculations;<br />
e.g. to calculate the volumetric reactant flow for a stack. Therefore it seems to be a simple<br />
question to ask for the correct reference temperature and pressure for STP. But the answer<br />
is not simple at all, as the following table shows [6]:<br />
T[ ◦ C] / [K] p abs [kPa] Publishing or establishing entity<br />
0 / 273.15 100.000 IUPAC (present definition)<br />
0 / 273.15 101.325 IUPAC (former definition), NIST, ISO 10780<br />
15 / 288.15 101.325 DIN IEC 62282-3-2 [7]<br />
20 / 293.15 101.325 EPA, NIST<br />
25 / 298.15 101.325 EPA<br />
25 / 298.15 100.000 SATP<br />
Which “standard” is to choose now? To calculate a gas volume flow ˙ V from a molar flow<br />
˙n or mass flow ˙m, the reference temperature and pressure need to be defined, also is mass<br />
flow controllers are used!<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
3.5 HHV and LHV 22<br />
The purpose of Mass flow controllers (MFCs) is to feed a required liquid or gas flow. From<br />
their measurement principle those components do measure a mass flow (e.g. kg/h or g/sec).<br />
But often volumetric values (e.g. l/min or m 3 /h) are more common. To transfer gas mass<br />
flows into gas volumetric flows, the gas density (kg/m 3 ) must be known.<br />
Since the gas density itself is depending on temperature and pressure, a reference temperature<br />
and pressure is needed. Well known MFCs manufacturers like Brooks, Bronkhorst,<br />
Bürckert, Aera or Omega do use the following temperature and pressure as reference for<br />
standard volume flows:<br />
T0 = 273.15 K and p0 = 101.325 kPa<br />
Using such types of MFCs require using this reference temperature and pressure to ensure<br />
correct calculations like described above!<br />
By the way The well known molar volume of an ideal gas is given at this temperature and<br />
pressure:<br />
3.5 HHV and LHV<br />
V0, mol = R · T0<br />
p0<br />
=22.414 ln/mol<br />
The higher heating value (HHV) of any fuel can be measured within a calorimeter. The result<br />
of this measurement is the energy of the chemical (oxidation) reaction starting at 25 ◦ C<br />
and ending at 25 ◦ C; therefore product water is condensed completely. Due to that the HHV<br />
includes the latent heat of water vaporization; but the specific amount of product water produced<br />
by the fuel oxidation reaction needs to be considered.<br />
The lower heating value (LHV) itself can not be measured directly; therefore the LHV needs<br />
to be calculated from HHV minus latent heat of water vaporization.<br />
3.6 Butler-Volmer equation<br />
The Butler-Volmer equation defines the relation between current density j and overpotential<br />
ϕ:<br />
j(ϕ) =j0<br />
<br />
αnF<br />
exp<br />
RT ϕ<br />
<br />
(1 − α)nF<br />
− exp<br />
RT<br />
<br />
ϕ<br />
This is the sum of an anodic and cathodic current j(ϕ) =ja(ϕ)+jc(ϕ) with:<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
3.6 Butler-Volmer equation 23<br />
<br />
αnF<br />
ja(ϕ) =j0 exp<br />
RT ϕ<br />
<br />
Side information: e x − e −x =2sinhx<br />
<br />
(1 − α)nF<br />
jc(ϕ) =−j0 exp<br />
RT<br />
With α =1/2 the Butler-Volmer equation can be dimplified to:<br />
<br />
j(ϕ) 1 nF<br />
=2sinh<br />
2 RT ϕ<br />
<br />
j0<br />
The following chart shows the anodic current (green line), the cathodic current (blue) and the<br />
Butler-Volmer equation itself (red):<br />
current deensity<br />
j [mA/cm²] / j / j0 8<br />
6<br />
4<br />
2<br />
0<br />
-100 -50 0 50 100<br />
-2<br />
-4<br />
-6<br />
-8<br />
overpotential [mV]<br />
In case of low overpotentials (|ϕ| < 10mV , α =1/2) the Butler-Volmer equation simplifies to:<br />
j(ϕ)<br />
j0<br />
= nF<br />
RT ϕ<br />
The following chart shows this linear relation between current density j and overpotential ϕ,<br />
with the slope m = nF/RT :<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
<br />
ϕ
3.6 Butler-Volmer equation 24<br />
j / j 0<br />
0.5<br />
0.4<br />
0.3<br />
0.2<br />
0.1<br />
0.0<br />
-10<br />
-0.1<br />
-5 0 5 10<br />
-0.2<br />
-0.3<br />
-0.4<br />
-0.5<br />
overpotential [mV]<br />
In case of high overpotentials (|ϕ| > 100mV , α =1/2) the Butler-Volmer equation simplifies<br />
to:<br />
ln j(ϕ)<br />
j0<br />
= 1 nF<br />
2 RT ϕ<br />
This relation becomes linear by using a logarithimx y-axes like in the next chart:<br />
ln ( j / j 0)<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
0<br />
-1<br />
0 50 100 150 200 250 300<br />
-2<br />
-3<br />
-4<br />
overpotential [mV]<br />
The slope of the blue dotted line m =1/2 nF/RT is the Tafel slope in the Tafel equation<br />
ϕ = m · j/j0.<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
4 Appendix 2: Constant values and<br />
abbreviations<br />
Constant values Source<br />
Faraday’s constant F = 96 485.3399 A sec/mol [8]<br />
Molar gas constant R =8.314472 J/K mol [8]<br />
Magnus equation constants C1 = 610.780 Pa<br />
C2 =17.08085<br />
C3 = 234.175 ◦ C<br />
Thermodynamics Source<br />
Standard temperature and pressure T0 = 273.15 K [9]<br />
(STP, see section 3.4) p0 = 101.325 kPa [9]<br />
Molar volume of ideal gases (at STP) V0, mol = RT0/p0 =22.414 ln/mol<br />
Standard ambient T and p Tc = 298.15 K [10]<br />
(SATP) pc = 100.000 kPa [10]<br />
LHV of H2 (at SATP) −ΔHH2O (g) = 241.82 kJ/mol [10], [11]<br />
ˆ=119.96 kJ/g [12]<br />
HHV of H2 (at SATP) −ΔHH2O (l) = 285.83 kJ/mol [10], [11]<br />
ˆ=141.79 kJ/g [12]<br />
Gibbs free enthalpy of H2O (g) (at SATP) −ΔGH2O (g) = 228.57 kJ/mol [10]<br />
Gibbs free enthalpy of H2O (l) (at SATP) −ΔGH2O (l) = 237.13 kJ/mol [10]<br />
Molar weights Source<br />
Molar weight water Mwater =18.0153 g/mol<br />
hydrogen<br />
oxygen<br />
nitrogen<br />
CO2<br />
MH2 =2.01588 g/mol<br />
MO2 =31.9988 g/mol<br />
MN2 =28.01348 g/mol<br />
MCO2 =44.0095 g/mol<br />
[8]<br />
[8]<br />
[8]<br />
[8]<br />
air Mair =28.9646431 g/mol [8]<br />
Molar fraction of O2 in air xO2 =0.21<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
25
4.1 Relevant units based on SI units 26<br />
Other relevant constants Source<br />
Individual gas constant of air Rair = R/Mair = 287.06 J/kg K<br />
Individual gas constant of water vapor Rw = R/Mw = 461.52 J/kg K<br />
Density of air (at STP) ρair =1.293 kg/m 3 n<br />
Density of H2 (at STP) ρH2 =0.0899 kg/m3 n<br />
Specific heat capacity of water (20 ◦ C) cp, m, water = 4182 J/kg K<br />
Density of water (20 ◦ C) ρwater = 998.2 kg/m 3<br />
Specific heat capacity of air (p = const) cp, m, air = 1005.45 J/kg K<br />
Specific heat capacity of air (V = const) cV, m, air = cp, m, air − Rair<br />
= 718.39 J/kg K<br />
Ratio of specific heats for air κ = cp/cV =1.40 or (κ − 1)/κ<br />
=0.285<br />
Specific heat capacity of water vapor cp, water = 1858.94 J/kg K<br />
Enthalpy of water vaporization (0 ◦ C) hwe = 2500.827 J/g<br />
4.1 Relevant units based on SI units<br />
Physical unit Unit name and symbol in SI unit in non SI units<br />
Force F Newton (N) kg m/s 2 -<br />
Pressure p Pascal (Pa) kg/(m s 2 ) N/m 2<br />
Energy/work E/W Joule (J) kg m 2 /s 2 Nm, Pa · m 3<br />
Power P Watt (W) kg m 2 /s 3 J/s<br />
Charge Q Coulomb (C) As -<br />
Voltage U Volt (V) kg m 2 /(s 3 A) W/A, J/C<br />
Resistance R Ohm (Ω) kg m 2 /(s 3 A 2 ) V/A<br />
4.2 Used abbreviations<br />
FCS <strong>Fuel</strong> cell system<br />
LHV Lower heating value<br />
HHV Higher heating value<br />
OCV Open circuit voltage<br />
EMF Electromotive force<br />
Nl (or ln), Nm 3 (or m 3 n) Norm liter or norm cubic meter<br />
(volume normalized to SATP)<br />
RH Relative humidity<br />
STP Standard temperature and pressure<br />
SATP Standard ambient temperature and pressure<br />
TD Thermodynamic<br />
WEG Water ethylene glycol<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5 Appendix 3: Air<br />
5.1 Moist air<br />
Water vapor and saturation pressure in moist air The water vapor partial pressure at<br />
saturation pws(t) is a function of temperature t [ ◦ C]. Its values are documented in tables (e.<br />
g. in [13]), but also a couple of equations allow its calculation. The most popular one is the<br />
Magnus equation, but others fit with a higher accuracy to the table values (e.g. equation with<br />
ten parameters in the documentation of Vaisalla products).<br />
Magnus equation:<br />
Water vapor saturration<br />
pressure [kPa]<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
pws(t) =C1 · exp C2 · t<br />
C3 + t<br />
t = C3 · ln pws(t)<br />
C1<br />
C2 − ln pws(t)<br />
C1<br />
[pws(t)] = Pa, [t] = ◦ C<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Temperature t [°C]<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
27
5.1 Moist air 28<br />
Specific humidity or humidity (mixing) ratio Specific humidity Y is the ratio between the<br />
actual mass of water vapor mw in moist air to the mass of the dry air mdry air.<br />
Y (t) = mw<br />
mdry air<br />
= Rair<br />
Rw<br />
pw(t)<br />
·<br />
pa − pw(t)<br />
= Mw<br />
Mair<br />
pw(t)<br />
·<br />
pa − pw(t) =0.622·<br />
pw(t)<br />
pa − pw(t)<br />
[Y (t)] = kg/kg<br />
The maximum amount of water vapor in the air is achieved when p w(t) =pws(t) the saturation<br />
pressure of water vapor at the temperature t.<br />
For other gases the molar weight has to be considered in the equation above. The constant<br />
value 0.622 is only valid for moist air!<br />
Since the water vapor pressure is small regarding to the atmospheric pressure, the relation<br />
between the humidity ratio and the saturation pressure is almost linear at temperature far<br />
below 100 ◦ C.<br />
Specific humidity at a saturation Ysat [kg/kg]<br />
Specific hummidity<br />
Y [kg/kg]<br />
2.0<br />
1.8<br />
1.6<br />
1.4<br />
1.2<br />
1.0<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0.0<br />
2.0<br />
1.8<br />
1.6<br />
1.4<br />
1.2<br />
1.0<br />
0.8<br />
0.6<br />
0.4<br />
0.2<br />
0.0<br />
101.3 kPa<br />
120 kPa<br />
150 kPa<br />
200 kPa<br />
RH is 100% (saturation)<br />
0 20 40 60 80 100<br />
Temperature t [°C]<br />
absolute pressure is 101.325 kPa<br />
100% RH<br />
75% RH<br />
50% RH<br />
25% RH<br />
0 20 40<br />
Temperature t [°C]<br />
60 80 100<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.1 Moist air 29<br />
Relative humidity RH (or ϕ) is the ratio of the partial pressure of water vapor pw(t) to the<br />
partial pressure of water vapor at saturation pws(t):<br />
RH can also be calculated with Y (t):<br />
ϕ = pw(t) aw(t) mw<br />
= =<br />
pws(t) aws(t) mws<br />
ϕ =<br />
Y (t)<br />
·<br />
Mw + Y (t) Mair<br />
p<br />
ps(t) =<br />
ϕ =0.0 − 1.0<br />
Y (t)<br />
0, 622 + Y (t) ·<br />
p<br />
ps(t)<br />
Absolute humidity or water vapor density Absolute humidity a(t) is the actual mass of<br />
water vapor present in the moist air and a function of t:<br />
a(t) = Mw<br />
R<br />
aturation asat [g/m3 absolute humidity at sa<br />
]<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
0<br />
pw(t) 1<br />
· =<br />
T0 + t Rw(t) ·<br />
pw<br />
K pw(t)<br />
=2.167g ·<br />
T0 + t J T0 + t<br />
RH is 100% (saturation)<br />
[a(t)] = g/m 3 , [t] = ◦ C<br />
0 20 40 60 80 100<br />
Temperature [°C]<br />
Molar fraction The molar fraction y(t) of water vapor is calculated as:<br />
y(t) = pw(t)<br />
pa<br />
y =0.0 − 1.0<br />
At standard pressure and 100 ◦ C y = 1 because there is only water in vapor phase (and no<br />
air).<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.1 Moist air 30<br />
Mol fraction<br />
y<br />
1.0<br />
0.9<br />
0.8<br />
0.7<br />
0.6<br />
0.5<br />
0.4<br />
0.3<br />
0.2<br />
0.1<br />
0.0<br />
1E-2<br />
1E-4<br />
1E-6<br />
1E-8<br />
-100 -80 -60 -40 -20 0<br />
101.325 kPa<br />
120 kPa<br />
150 kPa<br />
200 kPa<br />
0 20 40 60 80 100 120<br />
Dew point temperature Tdp [°C]<br />
Dew point temperature The dew point temperature (DPT) T dp is the temperature at which<br />
water vapor starts to condense out of the air, the temperature at which air becomes completely<br />
saturated. Above this temperature the moisture will stay in the air.<br />
If the DPT is close to the air temperature, the relative humidity is high, and if the dew point is<br />
well below the air temperature, the relative humidity is low.<br />
Tdp =<br />
<br />
C3 · ln ϕ + C2·t<br />
<br />
C3+t<br />
C2 − ln ϕ − C2·t<br />
C3+t<br />
To calculate RH from temperature and DPT:<br />
ϕ = pw(t)<br />
pws(t)<br />
= exp C2·Tdp<br />
C3+Tdp<br />
exp C2·t<br />
C3+t<br />
[Tdp] = ◦ C<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.1 Moist air 31<br />
Dew point temmperature<br />
[°C]<br />
relative hummidity<br />
RH [%]<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
-20<br />
100%<br />
90%<br />
80%<br />
70%<br />
60%<br />
50%<br />
40%<br />
30%<br />
20%<br />
10%<br />
0%<br />
100% RH<br />
80% RH<br />
60% RH<br />
40% RH<br />
20% RH<br />
0 20 40 60 80 100<br />
Temperature t [°C]<br />
DPT = t - 2K<br />
DPT = t - 5K<br />
DPT = t - 10K<br />
DPT = t - 20K<br />
0 20 40 60 80 100<br />
Temperature t [°C]<br />
Enthalpy The air enthalpy h is needed to calculate energy and power of air. The enthalpy<br />
of moist air consists of sensible heat and latent heat. Since moist air is a mixture of dry air<br />
and water vapor, the enthalpy includes the enthalpy of the dry air (the sensible heat h air) and<br />
the enthalpy of the evaporated water (the latent heat hwater).<br />
Specific enthalpy h [kJ/kg] of moist air is defined as the total enthalpy of the dry air and the<br />
water vapor mixture per kg of moist air.<br />
The enthalpy consists of three parts: a) warming up dry air from the reference temperature<br />
to the air temperature t, b) evaporating water inside the moist air and c) warming up water<br />
vapor from the reference temperature to the air temperature t:<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.1 Moist air 32<br />
with<br />
h = hair + Y · hwater<br />
hair = cp, air · t and hwater = cp, water · t + hwe<br />
h = cp, air · t + Y · (cp, water · t + hwe) [h] =J/g<br />
(5.1)<br />
where Y is the specific humidity of moist air, cp, air is the specific heat capacity of dry air,<br />
cp, water is the specific heat capacity of water vapor and hwe is the specific enthalpy of water<br />
vaporization. In case of dry air (Y =0), the enthalpy is a linear function of temperature (with<br />
slope cp, air). Heat capacities are depending on temperature (see chapter 3.3), but between<br />
0 and 100 ◦ C this may be neglected.<br />
Because the enthalpy is not an absolute value; only the enthalpy difference to a reference<br />
temperature can be calculated. Depending on the unit of temperature, the reference temperature<br />
is 0◦Cif[t] = ◦C;or0Kif[t] =K. If the temperature is given in ◦C, the enthalpy is 0 kJ<br />
kg<br />
at 0◦C. If temperature is given in K, the enthalpy is 0 kJ<br />
kg at 0 K.<br />
Due to the fact that only the enthalpy difference is used, it doesn’t mater if temperature is<br />
given in K or ◦ C! It’s just important not to switch between both units.<br />
The following chart show the enthalpy based on 0 ◦ C reference:<br />
Specific entthalpy<br />
h [kJ/kg]<br />
500<br />
450<br />
400<br />
350<br />
300<br />
250<br />
200<br />
150<br />
100<br />
50<br />
0<br />
100% RH<br />
75% RH<br />
50% RH<br />
25% RH<br />
dry (0%)<br />
absolute pressure is 101.325 kPa<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Temperature t [°C]<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.2 Energy and power of air 33<br />
Specific enthhalpy<br />
h [kJ/kg]<br />
2000<br />
1800<br />
1600<br />
1400<br />
1200<br />
1000<br />
800<br />
600<br />
400<br />
200<br />
0<br />
relative humidity is 100% (saturation)<br />
101.325 kPa<br />
120 kPa<br />
150 kPa<br />
200 kPa<br />
0 10 20 30 40 50 60 70 80 90 100<br />
Temperature t [°C]<br />
For dry air there is another empirical fit to calculate the enthalpy. This equation is used in<br />
DIN IEC 62282-3-2 [7]:<br />
h(t) =(A · t + B · t 2 + C · t 3 )/Mair<br />
with A =27.434, B=6.18/2000, C= −0.8987/3 · 10 6 .<br />
[h(t)] = kJ/kg, [t] = ◦ C or K<br />
Also here the temperature t can be given in ◦ C or K, see above. But this equation is only<br />
valid for dry air!<br />
5.2 Energy and power of air<br />
Energy and power of dry and wet are important to calculate e.g. the power demand for air<br />
humidification in a fuel cell system or to calculate efficiencies. See also ASME PTC 50-2002<br />
<strong>Fuel</strong> <strong>Cell</strong> Power Systems Performance [14] and DIN IEC 62282-3-2 <strong>Fuel</strong> cell technologies -<br />
Part 3-2: Stationary fuel cell power systems [7].<br />
The energy of air contains the air enthalpy and the pressure:<br />
The air power is given as:<br />
Eair = hair + Ep, air<br />
Pair = Eair · ˙mair<br />
[Eair] =kJ/kg<br />
[Pair] =kW<br />
The air enthalpy hair is defined by equation 5.1. Please be aware that always enthalpy<br />
differences are calculated and not the absolute enthalpy!<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 34<br />
The energy of compressed air is given by:<br />
Ep, air = Rair · T0 · ln p<br />
T0 and p0 are the reference temperature and pressure, see section 3.4.<br />
Example 1: How much power is required to heat dry air from 20 to 60 ◦ C with a mass flow<br />
of 30 kg/hr?<br />
Δh = h 60 ◦ C/0% − h 20 ◦ C/0% =40.218 kJ/kg<br />
P =Δh · ˙mair =40.218 kJ/kg · 30 kg/hr ·<br />
p0<br />
1<br />
hr/sec = 335 W<br />
3600<br />
Example 2: How much power is required to heat and humidify air at ambient pressure from<br />
20 ◦ C and 50% RH to 60 ◦ C and 80% RH? Air mass flow is 30 kg/hr.<br />
h 20 ◦ C/50% =38.56 kJ/kg<br />
h 60 ◦ C/80% = 363.18 kJ/kg<br />
Δh = 326.61 kJ/kg<br />
P =Δh · ˙mair = 326.61 kJ/kg · 30 kg/hr ·<br />
5.3 Air compression<br />
5.3.1 Definitions<br />
1<br />
hr/sec = 2, 722 W<br />
3600<br />
Adiabatic Process where no heat is transferred to or from the surroundings (dq = 0).<br />
Reversible Process can be reversed without loss or dissipation of energy (dS = 0).<br />
Isentropic Process with equal entropy<br />
Any reversible adiabatic process is an isentropic process (dq = dS = 0). But not vice versa!<br />
See also [15].<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 35<br />
5.3.2 Thermodynamics<br />
Compression and expansion<br />
A gas mass flow ˙m1 is compressed or expanded<br />
from pressure p1 and temperature T1 to pressure<br />
p2 and temperature T2. p2 >p1 in case of compression<br />
and p2 1 and for expansion Π < 1.<br />
A compression process consumes energy or<br />
work, an expansion process produces energy or work.<br />
Gas in<br />
W el<br />
Compressor<br />
W loss<br />
Gas out<br />
To calculate the efficiency of a compression process the theoretical energy demand needs to<br />
be calculated based on an isentropic process. In a real compression process there is always<br />
heat transferred to the surrounding (or cooling), and also gas mass flow losses can occur<br />
inside the compressor.<br />
Thermodynamic of gases<br />
Internal energy U The first law of thermodynamics [10] defines infinitesimal changes in<br />
internal energy dU of an ideal gas as changes in added heat dq and provided work dw:<br />
dU =dq +dw<br />
Enthalpy H is defined as H = U + pV . Infinitesimal changes dH are therefore defined as:<br />
dH =dU + pdV + V dp<br />
Heat capacities C describe the temperature dependencies of internal energy U and enthalpy<br />
H:<br />
CV =(∂U/∂T)V<br />
Cp =(∂H/∂T)p<br />
CV is the heat capacity at constant volume and Cp the heat capacity at constant pressure of<br />
an ideal gas:<br />
dU = CVdT and dH = CpdT (5.2)<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 36<br />
With pV = nRT it is dH =dU + nRdT and therefore:<br />
Cp − CV = nR<br />
For ideal gases the specific heat capacities cp and cV with [c] =J/mol K are independent of<br />
temperature! For ideal one atomic gases it ist:<br />
cp = Cp<br />
n<br />
And for ideal two atomic gases:<br />
5<br />
=<br />
2 R cV = CV<br />
n<br />
3 5<br />
= R κ =<br />
2 3 =1.67<br />
cp = 7<br />
2 R cV = 5 7<br />
R κ =<br />
2 5 =1.40<br />
The specific heat capacities cp, m and cV, m are given as:<br />
cp, m = cp/M and cV, m = cV/M [cp, m] =[cV, m] =J/kg K<br />
Polytropic process For all thermodynamic processes of ideal gases it is in general:<br />
pV n = const n = polytropic index (constant)<br />
The energy or work in a volume change process is in general:<br />
With pV = nRT it is:<br />
dw =dU = −p dV = CV dT<br />
CV dT/T = −nR dV/V<br />
The integral over start (1) and end state (2) is:<br />
CV<br />
2<br />
1<br />
dT/T = −nR<br />
2<br />
1<br />
dV/V<br />
CV ln (T2/T1) =−nR ln (V2/V1)<br />
Isentropic process The isentropic process is a special case of a polytropic process, where<br />
the polytropic index becomes the isentropic index or heat capacity ratio κ:<br />
n = κ = cp<br />
cV<br />
> 1<br />
With cp − cV = R, cV = CV/n and therefore CV cV<br />
nR = cp−cV<br />
1 = κ−1 it is:<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 37<br />
T1<br />
T2<br />
=<br />
κ−1 V2<br />
The following ratios are valid for an isentropic process:<br />
T1<br />
T2<br />
=<br />
κ−1 V2<br />
V1<br />
Volume work and technical work<br />
T1<br />
T2<br />
=<br />
V1<br />
p1<br />
p2<br />
κ−1<br />
κ<br />
p1<br />
p2<br />
=<br />
κ<br />
V2<br />
The volume (change) work wV,12 is the work that is done on a piston to reduce the start<br />
volume V1 to the end volume V2. It is equivalent in the change of inner energy. The volume<br />
work for an adiabatic process (dq =0) is defined as:<br />
V2<br />
wV, 12 = −<br />
V1<br />
p dV =<br />
2<br />
1<br />
dU = CV<br />
T2<br />
T1<br />
V1<br />
dT = CVΔT<br />
The technical work wt,12 is the work that is transferred from or mass flow via a technical<br />
system (for instance a mechanical axle). The technical work is equal to the enthalpy of the<br />
kinetic and potential energy of a stationary mass flow. The technical work wt,12 for compression<br />
is the work given to the drive shaft of the compressor; it contains the displacement work,<br />
but not the friction [16]!<br />
The technical work for an adiabatic process (dq =0) are defined as:<br />
p-V-chart<br />
p2<br />
wt, 12 =+<br />
p<br />
p2<br />
p1<br />
p1<br />
V dp =<br />
2<br />
V2<br />
2<br />
1<br />
dH = CpΔT<br />
Each compression process (polytropic, isentropic, isothermal etc.) follows a (similar but not<br />
the same) curve the pV chart from the start (1) to the end (2) point. Adding the different<br />
process areas shown in the pV chart gives:<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
V1<br />
1<br />
V
5.3 Air compression 38<br />
Therefore:<br />
V1<br />
p2V2 +<br />
V2<br />
p2<br />
p dV = p1V1 + V dp<br />
p1<br />
wt, 12 = wV,12 + p2V2 − p1V1<br />
Comment: For liquids ΔV ≈ 0 and therefore wV, 12 ≈ 0; then it is: wt, 12 ≈ (p2 − p1) · V<br />
The thermodynamic derivation (see above) defines the following ratios for the isentropic<br />
compression or expansion:<br />
Π=<br />
κ V1<br />
V2<br />
Therefore for the volume work it is:<br />
And similar for the technical work:<br />
and<br />
T1<br />
T2<br />
=<br />
κ−1 V2<br />
V1<br />
=Π κ−1<br />
κ<br />
<br />
wV, 12 = cV, m · (T2 − T1) =cV, m T1 · Π κ−1 <br />
κ − 1<br />
<br />
wt, 12 = cp, m · (T2 − T1) =cp, m T1 · Π κ−1 <br />
κ − 1<br />
wt, 12 = h2 − h1 with h = cp, m · T<br />
wt, 12 = κ · wV, 12 with κ = cp/cV<br />
The technical work is always more than the volume work, because κ>1.<br />
5.3.3 Ideal and real compressor<br />
Ideal The ideal compression is an isentropic process. There is no (energy or air mass flow)<br />
exchange with the surroundings.<br />
Real Due to friction the gas compression in a real compressor always dissipates energy to<br />
the surroundings or to the cooling system. This compression process is polytropic. After a<br />
polytropic compression the actual end temperature T2, act is always higher compared to an<br />
ideal isentropic compression T2, s:<br />
T2, act >T2, s<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 39<br />
The isentropic efficiency ηs of a compressor is the ratio between isentropic technical work<br />
ws, 12 and actual technical work wact, 12:<br />
ηs = ws, 12<br />
wact, 12<br />
= T2, s − T1<br />
T2, act − T1<br />
wact, 12 is ws, 12 plus specific friction work (dessipitation).<br />
= h2, s − h1<br />
h2, act − h1<br />
To calculate the isentropic work, first of all the isentropic end temperature T2, s needs to be<br />
calculated:<br />
T2, s = T1 · Π κ−1<br />
κ<br />
Now the isentropic technical work can be calculated as:<br />
<br />
ws, 12 = cp, m · (T2, s − T1) =cp, m T1 · Π κ−1 <br />
κ − 1<br />
For dry air at room temperature (25 ◦ C) the isentropic work ws, 12 as a function of pressure<br />
ratio Π looks as following:<br />
Isentropic work w [kJ/kg]<br />
160<br />
140<br />
120<br />
100<br />
80<br />
60<br />
40<br />
20<br />
0<br />
1.0 1.5 2.0 2.5 3.0 3.5 4.0<br />
Finally the isentropic power of compression is:<br />
Pressure ratio P [-]<br />
Ps, 12 = ˙m · ws, 12<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 40<br />
5.3.4 Examples<br />
Example 1: Isentropic efficiency<br />
Air is compressed from 1 bara at 30 ◦ C (303.15 K) to 3 bara at 150 ◦ C (423.15 K). In the<br />
compressor there is no energy or air mass flow loss to the surroundings.<br />
The actual technical work that is done at the air is:<br />
Isentropic temperature:<br />
wact = cp, m · (T2, act − T1) = 1005<br />
T2, s = T1 · Π κ−1<br />
κ = 303.15 K ·<br />
Isentropic technical work:<br />
Isentropic efficiency:<br />
ws = cp, m · (T2, s − T1) = 1005<br />
ηs = ws<br />
wact<br />
Example 2: Electric efficiency<br />
= 112.4 kJ/kg<br />
J<br />
kJ<br />
· 120 K = 120.6<br />
kg · K kg<br />
0.285 3bara<br />
= 414.6K or 141.5<br />
1bara<br />
◦ C<br />
J<br />
kJ<br />
· (414.6K− 303.15 K) = 112.4<br />
kg · K kg<br />
120.6 kJ/kg<br />
=0.932 or 93.2%<br />
27 kg/h air is compressed from 2.4 to 6 barabs, the electric power consumption of the compressor<br />
is 1305 W:<br />
˙m =27kg/h, p1 =2.4 barabs and T1 =18 ◦ = 291K<br />
p2 = 6 barabs and Pel = 1305 W<br />
Air mass flow losses due to gaps and other heat losses to the surroundings are neglected!<br />
But of course heat is transferred to the cooling!<br />
The isentropic technical work given to the air is:<br />
<br />
ws = cp, m T1 · Π κ−1 <br />
κ − 1 = 1005<br />
Isentropic technical power:<br />
<br />
0.285<br />
J<br />
6bar<br />
· 291 K ·<br />
− 1 =87.6<br />
kg · K 2.4bar<br />
kJ<br />
kg<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
5.3 Air compression 41<br />
Ps = ˙m · ws =87.6 kJ<br />
· 27 kg/h = 2365.2 kJ/h = 657.0 W<br />
kg<br />
The electric efficiency of this compressor is:<br />
5.3.5 Comment<br />
ηel = Ps<br />
Pel<br />
= 657.0 W<br />
1305 W<br />
=0.50 or 50%<br />
The technical work equation is often given in literature with different indices. The next two<br />
equations show the relation between κ, R, cp and cV:<br />
κ cp/cV<br />
· R =<br />
κ − 1 cp/cV − 1 · (cp − cV) =<br />
1<br />
· R =<br />
κ − 1<br />
cp<br />
cp − cV<br />
· (cp − cV) =cp<br />
1<br />
cp/cV − 1 · (cp − cV) = cV<br />
· (cp − cV) =cV<br />
cp − cV<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
6 Appendix 4: <strong>Fuel</strong> cell stack water<br />
management<br />
6.1 Assumptions<br />
Simple calculation of fuel cell stack water management, based on calculation of RH at cathode<br />
exhaust with the following assumptions:<br />
1. The product water is removed via cathode side; that means there is no water removal<br />
via anode side.<br />
2. Cathode air is heated inside the stack to a specific temperature t (which does not<br />
necessarily have to be the stack coolant outlet temperature).<br />
3. Condensation is not considered! All water leaves the stack as water vapor.<br />
4. There is no water input via anode or cathode into the stack. That means that cathode<br />
air and hydrogen at stack inlet are dry.<br />
5. All gases (air, hydrogen, water vapor) are treated as ideal gases.<br />
6.2 Derivation 1 (via volume flow and absolute humidity)<br />
Product water (PW) ˙mw = 1<br />
Volume flow PW (=H2)<br />
2F · Mw<br />
Vw(t, ˙ p) =<br />
[˙mw] =g/Asec<br />
1<br />
2F · Vm(t, p) [ ˙ Vw] =m3 Volume flow O2<br />
˙VO2<br />
1 (t, p) = 4F<br />
/Asec<br />
· Vm(t, p) [ ˙ VO2 ]=m3 Air volume flow<br />
/Asec<br />
˙ Vair(t, p, λ, x) = ˙ λ<br />
VO2 (t, p) · x [ ˙ Vair] =m3 /Asec<br />
Volume flow at cathode exhaust (less consumed oxygen, plus product water vapor):<br />
˙Vout(t, p, λ, x) = ˙ Vair(t, p, λ, x) − ˙ VO2 (t, p)+ ˙ Vw(t, p) = 1<br />
4F Vm(t,<br />
<br />
λ<br />
p) · − 1+2<br />
x<br />
[ ˙ Vout] =m 3 /Asec<br />
Absolute humidity at cathode inlet (assumption!): ain =0g/m 3<br />
Absolute humidity at cathode outlet:<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />
42
6.3 Derivation 2 (via mass flow and specific humidity) 43<br />
aout(t, p, λ, x) =<br />
Relative humidity at cathode outlet:<br />
Simplification of deviation 1<br />
˙mw<br />
+ ain [aout]<br />
˙Vout(t, p, λ, x)<br />
φ(t, p, λ, x) = aout(t, p, λ, x)<br />
as(t)<br />
=g/m 3<br />
φ =0.0 − 1.0<br />
This calculation can be combined and simplified to the following formula:<br />
Or in other terms:<br />
φ(t, p, λ, x) =<br />
1/2F ·Mw<br />
1/4F ·Vm(t,p)·(λ/x+1)<br />
Mw/R · ps(t)/t + T0<br />
ϕ =<br />
1<br />
2 · pws ·<br />
pcathode out<br />
<br />
=<br />
1+ λcathode<br />
xO 2<br />
2<br />
λ/x +1 ·<br />
p<br />
ps(t)<br />
For the dew point temperature this calculation can be simplified to the following formula<br />
(which is independent of temperature t!):<br />
Tdp(p, λ, x) = C3 · ln K(p, λ, x)<br />
C2 − ln K(p, λ, x)<br />
<br />
p<br />
with K(p, λ, x) = 1<br />
2 · C1 · 1+ λ<br />
<br />
x<br />
6.3 Derivation 2 (via mass flow and specific humidity)<br />
˙mair in = 1<br />
4F · Mair · λ<br />
· I<br />
x<br />
˙mw = 1<br />
2F · Mw · I<br />
˙mO2 consumed = 1<br />
4F<br />
· MO2 · I<br />
˙mcathode dry out = ˙mair in − ˙mO2 consumed = 1<br />
4F<br />
The specific humidity at cathode outlet is:<br />
· Mair<br />
<br />
λ<br />
x − M <br />
O2<br />
· I<br />
Mair<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
6.4 Conclusion 44<br />
Y =<br />
˙mw<br />
˙mcathode dry out<br />
And the relative humidity at cathode outlet is then:<br />
φ =<br />
Y<br />
·<br />
Mw + Y Mair<br />
6.4 Conclusion<br />
p<br />
ps(t) =<br />
Y<br />
0.622 + Y ·<br />
2 · Mw<br />
= <br />
λ<br />
Mair · x − M 2 · 0.622<br />
= <br />
O λ<br />
2<br />
Mair<br />
x − 1.105<br />
p<br />
ps(t) =<br />
With this simplified model for the cathode exhaust . . .<br />
2<br />
·<br />
λ<br />
x +0.895<br />
p<br />
ps(t) =<br />
p<br />
1<br />
2 · ps(t) 0.895 + λ<br />
x<br />
1. . . . the relative humidity is a function of temperature, pressure and stoichiometry.<br />
2. . . . the dew point temperature is a function of pressure and stoichiometry (and independent<br />
of temperature)!<br />
There both derivations 1 and 2 are coming nearly to the same result; with one minor difference:<br />
The ”1” in derivation 1 is ”0.895” in derivation 2.<br />
I currently really don’t know in which derivation there is an error (in reasoning). But this<br />
failure is not too significant, because λ/x ≫ 1.<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
Bibliography 45<br />
Bibliography<br />
[1] Arnold Lamm Wolf Vielstich and Hubert A. Gasteiger. Handbook of <strong>Fuel</strong> <strong>Cell</strong>s Vol. 1.<br />
John Wiley & Sons Ltd, 1 edition, 2003.<br />
[2] U.S. Department of Energy. <strong>Fuel</strong> <strong>Cell</strong> Handbook. National Technical Information Service,<br />
U.S. Department of Commerce, 7 edition, 2004.<br />
[3] James Larminie and Andrew Dicks. <strong>Fuel</strong> <strong>Cell</strong> Systems Explained. John Wiley & Sons<br />
Ltd, 2 edition, 2004.<br />
[4] Performance Working Group within the SAE <strong>Fuel</strong> <strong>Cell</strong> Standards Committee. SAE<br />
J2617: Recommended Practice for testing Performance of PEM <strong>Fuel</strong> <strong>Cell</strong> Stack Subsystem<br />
for Automotive Applications. SAE International, Nov2007.<br />
[5] <strong>Fuel</strong> <strong>Cell</strong> Technologies BSI Technical Committee GEL/105. DD IEC TS 62282-1:2005<br />
<strong>Fuel</strong> cell technologies - Part 1: Terminology. BSI British Standards, 18 April 2005.<br />
[6] Wikipedia. Standard conditions for temperature and pressure.<br />
http://en.wikipedia.org/wiki/Standard conditions for temperature and pressure, July<br />
2010.<br />
[7] DIN. DIN IEC 62282-3-2 <strong>Fuel</strong> cell technologies - Part 3-2: Stationary fuel cell power<br />
systems. DIN Deutsches Institut fuer Normung e. V., July 2009.<br />
[8] http://physics.nist.gov/cuu/Constants/index.html. NIST Fundamental Physical Constants.<br />
[9] DIN. DIN 1343 Reference conditions, normal conditions, normal volume; concepts and<br />
values. DIN Deutsches Institut fuer Normung e. V., 1990.<br />
[10] Peter W. Atkins. Physikalische Chemie, volume 2. VCH Verlagsgesellschaft GmbH,<br />
1990.<br />
[11] DIN. DIN 51857 Gaseous fuels and other gases - Calculation of calorific value, density,<br />
relative density and Wobbe index of pure gases and gas mixtures. DIN Deutsches<br />
Institut fuer Normung e. V., 1990.<br />
[12] SAE. SAE J2572: Recommended Practice for Measuring <strong>Fuel</strong> Consumption and Range<br />
of <strong>Fuel</strong> <strong>Cell</strong> and Hybrid <strong>Fuel</strong> <strong>Cell</strong> Vehicles <strong>Fuel</strong>led by Compressed Gaseous Hydrogen.<br />
SAE International, 2008-10.<br />
[13] David R. Lide. CRC Handbook of Chemistry and Physics. CRC Press, 1990.<br />
[14] A. J. Leo (Chair). ASME PTC 50-2002 <strong>Fuel</strong> <strong>Cell</strong> Power Systems Performance. The<br />
American Society of Mechanical Engineers, November 29, 2002.<br />
[15] http://www.wikipedia.org/. Wikipedia.<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza
Bibliography 46<br />
[16] Prof. Dr. Dieter Winklmair. Script Energie- und Wärmechnik,<br />
http://www.winklmair.de/ewt/folien-1.pdf, August 2010.<br />
<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza