16.04.2013 Views

Fuel Cell Formulary - ZSW

Fuel Cell Formulary - ZSW

Fuel Cell Formulary - ZSW

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Just another<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong><br />

by Dr. Alexander Kabza<br />

This version is from February 27, 2012.


Contents 2<br />

Contents<br />

1 Fundmentals 4<br />

1.1 H2/O2 electrochemical device . . . . . . . . . . . . . . . . . . . . . . . . . . . 4<br />

1.2 Reactant consumption and feed . . . . . . . . . . . . . . . . . . . . . . . . . . 6<br />

1.3 Energy content of hydrogen . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

1.4 <strong>Fuel</strong> cell stack power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

1.5 <strong>Fuel</strong> cell stack efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

1.5.1 Different efficiencies . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8<br />

1.5.2 Efficiency calculation example . . . . . . . . . . . . . . . . . . . . . . 12<br />

1.5.3 Electric efficiency calculation . . . . . . . . . . . . . . . . . . . . . . . 12<br />

1.6 Polarization curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13<br />

2 <strong>Fuel</strong> cell system (FCS) 14<br />

2.1 Anode subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

2.2 Cathode subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

2.3 Coolant subsystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />

2.4 FCS efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17<br />

2.5 Example calculation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18<br />

3 Appendix 1: Basics 19<br />

3.1 Thermodynamic basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19<br />

3.2 Energy and relevant energy units . . . . . . . . . . . . . . . . . . . . . . . . . 20<br />

3.3 Temperature dependency of thermodynamic values . . . . . . . . . . . . . . 20<br />

3.4 Standard temperature and pressure . . . . . . . . . . . . . . . . . . . . . . . 21<br />

3.5 HHV and LHV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

3.6 Butler-Volmer equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22<br />

4 Appendix 2: Constant values and abbreviations 25<br />

4.1 Relevant units based on SI units . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

4.2 Used abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<br />

5 Appendix 3: Air 27<br />

5.1 Moist air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

5.2 Energy and power of air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

5.3 Air compression . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

5.3.1 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

5.3.2 Thermodynamics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35<br />

5.3.3 Ideal and real compressor . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

5.3.4 Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40<br />

5.3.5 Comment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


Contents 3<br />

6 Appendix 4: <strong>Fuel</strong> cell stack water management 42<br />

6.1 Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<br />

6.2 Derivation 1 (via volume flow and absolute humidity) . . . . . . . . . . . . . . 42<br />

6.3 Derivation 2 (via mass flow and specific humidity) . . . . . . . . . . . . . . . . 43<br />

6.4 Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1 Fundmentals<br />

This is a collection of relevant formulas, calculations and equations for designing a fuel cell<br />

system (FCS)<br />

1.1 H2/O2 electrochemical device<br />

In case of the hydrogen (H2) oxidation with oxygen (O2) the enthalpy ΔH is the enthalpy of<br />

water (H2O) formation and also known as the heating value of H2.<br />

In general, ΔH defines the chemical energy content; and ΔH is negative if energy is released<br />

by a chemical reaction (exothermal).<br />

Depending whether the product water is in either gaseous or liquid phase, there are two<br />

values for ΔH: The lower heating value (LHV) and the higher heating value (HHV). ΔH is a<br />

function of temperature and pressure; values at thermodynamic standard conditions (25 ◦ C<br />

and 101.325 kPa, see section 3.4) for LHV and HHV are defined as:<br />

H2 + 1<br />

2 O2 → H2O (g)<br />

H2 + 1<br />

2 O2 → H2O (l)<br />

ΔHH2O (g) = −LHV = −241.82 kJ/mol<br />

ΔHH2O (l) = −HHV = −285.83 kJ/mol<br />

Please note that LHV and HHV do have positive signs whereas ΔH is negative.<br />

The difference between LHV and HHV of 44.01 kJ/mol is equal to the molar latent heat of<br />

water vaporization.<br />

The free or Gibbs enthalpy G = H − TSdefines the energy which is available and can<br />

be extracted to do external work, neglecting any work done by changes in pressure and/or<br />

volume.<br />

The (thermodynamic) electromotive force (EMF) or reversible open cell voltage (OCV) E 0 of<br />

each electrochemical device is given by:<br />

E 0 = ΔG<br />

n · F<br />

where n is the amount of exchanged electrons and F is Faraday’s constant (see chapter 4).<br />

For hydrogen oxidation or water formation n =2.<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

4


1.1 H2/O2 electrochemical device 5<br />

The free enthalpies of water formation are:<br />

ΔGH2O (g) = −228.57 kJ/mol and ΔGH2O (l) = −237.13 kJ/mol<br />

therefore the reversible voltages are:<br />

E 0 g = −ΔGH2O (g)<br />

2F<br />

=1.184 V and E 0 l = −ΔGH2O (l)<br />

2F<br />

=1.229 V (1.1)<br />

Beside the fact that these voltages are the maximum voltages which can theoretically be<br />

extracted from the electrochemical reaction of H2 and O2, two other voltages are also important<br />

for efficiency calculation (see later on). If all the chemical energy of hydrogen (i.e. its<br />

heating value or enthalpy of water formation) were transformed into electric energy (which is<br />

obviously not the case), the following voltage equivalents would result:<br />

E 0 LHV<br />

LHV<br />

=<br />

2F =1.253 V and E0 HHV<br />

HHV = =1.481 V (1.2)<br />

2F<br />

Those two values are the voltage equivalent to the enthalpy ΔH, also called thermal cell<br />

voltage (see [1], page 27).<br />

All those thermodynamic values are a function of temperature. The temperature dependency<br />

(of absolute values) is as following:<br />

T [°C] 0 25 50 100 200 400 600 800 1000<br />

LHV [kJ/mol] 241.6 241.8 242.1 242.6 243.5 245.3 246.9 248.2 249.3<br />

HHV [kJ/mol] 286.6 285.8 285.0 283.4 280.0 265.8 242.3 218.8 195.3<br />

ΔG H2O (g) [kJ/mol] 229.7 228.6 227.5 225.2 220.4 210.3 199.7 188.7 177.5<br />

ΔG H2O (l) [kJ/mol] 241.3 237.1 233.1 225.2 210.0 199.0 230.4 267.1 308.3<br />

Enthalpy<br />

[kJ/mol]<br />

300<br />

290<br />

280<br />

270<br />

260<br />

250<br />

240<br />

230<br />

220<br />

210<br />

200<br />

Calculated with HSC Chemistry 6.21<br />

HHV<br />

LHV<br />

DG H2O(l)<br />

DG H2O(g)<br />

0 20 40 60 80 100 120 140 160 180 200<br />

T [°C]<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.2 Reactant consumption and feed 6<br />

1.2 Reactant consumption and feed<br />

The reactants H2 and O2 are consumed inside the fuel cell stack by the electrochemical<br />

reaction. Based on Faraday’s laws of electrolysis the molar flows ˙n are defined as following:<br />

˙nO2<br />

˙nH2<br />

= I · N<br />

4F<br />

= I · N<br />

2F<br />

1<br />

= · ˙nH2 [˙nO2<br />

2<br />

[˙nH2 ]=mol/sec (1.3)<br />

]=mol/sec<br />

I is the stack load (electric current, [I] =A), and N is the amount of single cells (cell count,<br />

[N] =−). 2 respectively 4 is the number of electrons transferred per H2 or O2 during the<br />

electrochemical reaction. F is the Faraday constant.<br />

The stoichiometry λ defines the ratio between reactant feed into the stack and reactant consumption<br />

in the stack. Due to stack design and water management issues the stoichiometry<br />

is always above one:<br />

λ =<br />

˙nfeed<br />

˙nconsumed<br />

> 1 [λ] =−<br />

The molar flows of reactants H2 and air into the fuel cell stack are defined by an anode and<br />

cathode stoichiometry λ:<br />

˙nH2, in =˙nH2 · λanode =<br />

˙nair, in = ˙nO2<br />

xO2<br />

I · N<br />

2F<br />

· λanode<br />

I · N<br />

· λcathode = · λcathode<br />

4F · xO2<br />

where xO2 is the oxygen content in air.<br />

The molar flows of unconverted (dry) reactants at the stack exhaust are given as:<br />

˙nH2, out =˙nH2, in − ˙nH2<br />

˙nair, out =˙nair, in − ˙nO2<br />

= I · N<br />

2F · (λanode − 1)<br />

I · N<br />

=<br />

4F ·<br />

<br />

λcathode<br />

− 1<br />

xO2<br />

It is very common to give the reactant feed either as a mass or volume flow. The mass flow<br />

˙m is the product of molar flow ˙n and molar weight M:<br />

˙m =˙n · M [˙m] =g/sec or kg/h<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.3 Energy content of hydrogen 7<br />

The volume flow ˙ V is calculated by the gas density ρ or the molar gas volume V0, mol:<br />

˙V = ˙m<br />

ρ = V0, mol · ˙n [ ˙ V ]=l/min or m 3 /h<br />

Both the gas density ρ and the molar gas volume V0, mol are temperature and pressure dependent!<br />

Therefor the referring temperature and pressure need to be defined. A letter N<br />

or n indicates that the volume flow is normalized to a specific reference temperature and<br />

pressure (e.g. [ ˙ V ]=Nl/min or ln/min). For more information see section 3.4.<br />

1.3 Energy content of hydrogen<br />

Hydrogen contains chemical energy; and the amount of chemical energy is given by the HHV<br />

(or sometimes LHV) of H2. The mass specific chemical energy of H2 is therefore:<br />

WH2, HHV = HHV<br />

M<br />

= 285.83 kJ/mol<br />

2.02 g/mol<br />

WH2, LHV = 119.96 kJ/g<br />

= 141.79 kJ/g<br />

The volume specific chemical energy of H2 (at 273.15 K and 101.325 kPa) is:<br />

WH2, HHV = HHV<br />

V0,mol<br />

The chemical power of an H2 flow is:<br />

= 285.83 kJ/mol<br />

22.414 ln/mol =12.75 J/mln =12.75 kJ/m 3 n =3.54 kWh/m3 n<br />

WH2, LHV =10.79 J/mln =10.79 kJ/m 3 n =3.00 kWh/m3 n<br />

PH2, HHV = HHV · ˙nH2<br />

[PH2, HHV] =J/sec = W<br />

With equations 1.2 and 1.3, the chemical power H2 consumed in a stack with N cells at the<br />

stack load I can be expressed as:<br />

1.4 <strong>Fuel</strong> cell stack power<br />

PH2, HHV =1.481 V · N · I<br />

Electric stack power Pel is the product of stack voltage and stack load:<br />

Pel = UStack · I =Ave<strong>Cell</strong>· N · I<br />

where Ave<strong>Cell</strong> = UStack/N is the average single cell voltage ([Ave<strong>Cell</strong>] = V).<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.5 <strong>Fuel</strong> cell stack efficiency 8<br />

Thermal stack power Ptherm is the rest of the chemical power PH2, HHV of the consumed<br />

fuel (hydrogen) which is not converted into electric power:<br />

Ptherm = PH2, HHV − Pel<br />

For the hydrogen fuel cell it is defined based on HHV as:<br />

Ptherm, HHV =(1.481 V − Ave<strong>Cell</strong>) · N · I = Pel<br />

<br />

1.481 V<br />

− 1<br />

Ave<strong>Cell</strong><br />

1.481 V is the voltage equivalent of the HHV according to equation 1.2. To calculate the<br />

thermal power based on LHV this voltage equivalent needs to be replaced by 1.253 V.<br />

(1.4)<br />

Recoverable heat The recoverable heat is the part of the thermal stack power that is<br />

converted into usable heat. This is e.g. the heat transferred into the (liquid) coolant and can<br />

be calculated as following:<br />

Precoverable heat = ˙ V · cp · ΔT · ρ<br />

Coolant parameters are: ˙ V is the volume flow, cp is the heat capacity, ΔT is the temperature<br />

increase and ρ is the density.<br />

It is a fact that not all thermal power can be transferred to coolant; therefore:<br />

The rest is wasted heat:<br />

This waste heat consists of two parts:<br />

Precoverable heat


1.5 <strong>Fuel</strong> cell stack efficiency 9<br />

All efficiencies can be based on either LHV or HHV of the fuel. Is it true that in the U.S. HHV<br />

is used, whereas LHV is common practice in Europe? I don’t know.<br />

In general the efficiency η is defined as:<br />

η =<br />

(useful) energy output<br />

energy input<br />

= (useful) power output<br />

power input<br />

Maximum efficiency The maximum (thermodynamic and ideal) efficiency is the relation<br />

between the enthalpy (heating value) ΔH and the (maximum extractable) Gibbs free enthalpy<br />

ΔG of the electrochemical device:<br />

For the hydrogen cell it is:<br />

ηel, max, LHV = −ΔGH2O (g)<br />

LHV<br />

ηel, max, HHV = −ΔGH2O (l)<br />

HHV<br />

ηel, max = ΔG<br />

ΔH<br />

= E0 g<br />

E 0 LHV<br />

= E0 l<br />

E 0 HHV<br />

= 1.184 V<br />

= 1.229 V<br />

1.253 V =94.5%<br />

1.481 V =83.1%<br />

The Handbook of <strong>Fuel</strong> <strong>Cell</strong>s [1] calls this simply “ideal efficiency”.<br />

The <strong>Fuel</strong> <strong>Cell</strong> Handbook [2] calls this efficiency the “thermal efficiency of an ideal fuel cell<br />

operating reversibly on pure hydrogen and oxygen at standard conditions”.<br />

<strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3] calls this efficiency “the maximum efficiency possible” or<br />

“maximum efficiency limit” which explains it also very well.<br />

Electric efficiency The (thermodynamic) electric efficiency of a fuel cell (stack) is defined<br />

as:<br />

ηel =<br />

Pel<br />

Pfuel, consumed<br />

It can be defines on both LHV and HHV. Due to the fact that for hydrogen the HHV is 18.2%<br />

higher than LHV, the efficiency based on HHV is 18.2% lower than based on LHV.<br />

The electric efficiency is defined as (more details see section 1.5.3):<br />

Pel<br />

ηel, LHV =<br />

Pfuel, consumed<br />

= Ave<strong>Cell</strong><br />

1.253 V<br />

How this efficiency is named in literature and codes & standards:<br />

and ηel, HHV = Ave<strong>Cell</strong><br />

1.481 V<br />

(1.5)<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.5 <strong>Fuel</strong> cell stack efficiency 10<br />

1. “Load efficiency” in the Handbook of <strong>Fuel</strong> <strong>Cell</strong>s [1], refers to both LHV and HHV.<br />

2. The <strong>Fuel</strong> <strong>Cell</strong> handbook [2] refers to HHV and says “this efficiency is also referred to<br />

as the voltage efficiency”.<br />

3. “<strong>Cell</strong> efficiency” in <strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3], and refers to LHV.<br />

4. SAE J2617 [4] calls this efficiency “stack sub-system efficiency” and refers to LHV.<br />

<strong>Fuel</strong> electric efficiency The fuel efficiency considers the amount of hydrogen feed to the<br />

stack (and not only the amount of consumed hydrogen). It is defined as:<br />

Based on LHV or HHV this is:<br />

Pel<br />

ηfuel, el, LHV =<br />

Pfuel, feed<br />

Ave<strong>Cell</strong><br />

=<br />

1.253 V · λanode<br />

Pel<br />

ηfuel, el =<br />

Pfuel, feed<br />

and ηfuel, el, HHV =<br />

Obviously, the relation between ηfuel, el and ηel is the anode stoic:<br />

How this efficiency is named in literature:<br />

ηfuel, el = ηel<br />

λanode<br />

Ave<strong>Cell</strong><br />

1.481 V · λanode<br />

1. <strong>Fuel</strong> <strong>Cell</strong> Systems Explained [3] calls this efficiency simply “efficiency” (of either LHV<br />

or HHV).<br />

2. <strong>Fuel</strong> <strong>Cell</strong> Handbook [2] says: “To arrive at the net cell efficiency, the voltage efficiency<br />

must be multiplied by the fuel utilization.” In my opinion it is not correct to call this<br />

efficiency voltage efficiency (see next paragraph).<br />

Voltage efficiency is the ratio between average and reversible cell voltage E 0 (equation<br />

1.1):<br />

ηvoltage = Ave<strong>Cell</strong><br />

E 0<br />

Normally the voltage efficiency is based on ΔGH2O (l) :<br />

ηvoltage = Ave<strong>Cell</strong><br />

E 0 l<br />

= Ave<strong>Cell</strong><br />

1.229 V<br />

ηvoltage = ηel, HHV · ηel, max, HHV = Ave<strong>Cell</strong><br />

· 0.831<br />

1.481 V<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.5 <strong>Fuel</strong> cell stack efficiency 11<br />

Thermal efficiency ηtherm can be calculated according the electric efficiency:<br />

Based on HHV it is:<br />

ηtherm =<br />

ηtherm, HHV =<br />

Ptherm<br />

Pfuel, consumed<br />

1.481 V − Ave<strong>Cell</strong><br />

1.481 V<br />

Recovered heat efficiency Due to the fact that not all thermal power P therm is transferred<br />

into the coolant the recovery heat efficiency can be calculated:<br />

For HHV this is:<br />

ηrecovered heat = Precovered heat<br />

Ptherm<br />

ηrecovered heat, HHV = Precovered heat<br />

Ptherm, HHV<br />

Overall stack efficiency can be calculated as:<br />

=<br />

ηoverall = Pel + Ptherm<br />

Pfuel, consumed<br />

˙V · cp · ΔT · ρ<br />

(1.481 V − Ave<strong>Cell</strong>) · N · I<br />

This (thermodynamic) efficiency needs to be ηoverall =1, because the consumed hydrogen<br />

is converted completely in electric and thermal power:<br />

Therefore it is also:<br />

=1<br />

Pfuel, consumed = Pel + Ptherm<br />

ηoverall = ηel + ηtherm<br />

Total efficiency is maybe more reasonable and defined as:<br />

ηtotal = Pel + Precoverable heat<br />

Pfuel, feed<br />

Now obviously ηtotal < 1, because Precoverable heat Pfuel, consumed!<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

< 1


1.5 <strong>Fuel</strong> cell stack efficiency 12<br />

1.5.2 Efficiency calculation example<br />

A fuel cell stack produces 10 kW electric power and consumes 150 ln/min H2. The stack<br />

runs at 600mV average cell voltage.<br />

What is the electric efficiency, the fuel efficiency and what is the anode stoichiometry?<br />

˙n =<br />

ηfuel, el, LHV =<br />

ηel, LHV = Ave<strong>Cell</strong><br />

E 0 LHV<br />

150 ln/min<br />

22.414 ln/mol · 60 sec/min<br />

Pel<br />

=<br />

˙nH2 · LHV<br />

λanode = ηel, LHV<br />

ηfuel, el, LHV<br />

1.5.3 Electric efficiency calculation<br />

How to come from ηel, LHV =<br />

With equations 1.2 and 1.3 it is:<br />

Pel<br />

ηel, LHV =<br />

Pfuel, consumed<br />

Pel<br />

Pfuel, consumed<br />

= 0.6V<br />

1.253 V =47.9%<br />

=0.1115 mol/sec<br />

10 kJ/sec<br />

0.1115 mol/sec · 241.82 kJ/mol =37.1%<br />

to Ave<strong>Cell</strong><br />

1.253 V ?<br />

= 47.9%<br />

37.1% =1.29<br />

= Ave<strong>Cell</strong> · N · I Ave<strong>Cell</strong> · 2F<br />

=<br />

˙nH2 · LHV LHV<br />

= Ave<strong>Cell</strong><br />

E 0 LHV<br />

= Ave<strong>Cell</strong><br />

1.253 V<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


1.6 Polarization curve 13<br />

1.6 Polarization curve<br />

The polarization curve or current voltage characteristic (U-I-curve) plots the cell voltage versus<br />

current density of a single cell (or stack). The following chart shows an pol curve example,<br />

including the electric and thermal power based on LHV or HHV (equation 1.4), and the<br />

electric efficiency based on LHV (1.5).<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


2 <strong>Fuel</strong> cell system (FCS)<br />

IEC 62282-1:2005 [5] defines the main components of a fuel cell system and draws the<br />

system boundary around:<br />

Power inputs<br />

Electrical<br />

thermal<br />

Air<br />

Ventilation<br />

Inert gas<br />

Water<br />

<strong>Fuel</strong><br />

EMD,<br />

vibration,<br />

wind, rain,<br />

temperature, etc.<br />

<strong>Fuel</strong><br />

Processing<br />

System<br />

Air<br />

Processing<br />

System<br />

Ventilation<br />

System<br />

Thermal<br />

Management<br />

System<br />

<strong>Fuel</strong> <strong>Cell</strong><br />

Module (Stack)<br />

Water<br />

Treatment<br />

System<br />

Automatic<br />

Control<br />

System<br />

Power<br />

Conditioning<br />

System<br />

Internal power<br />

needs<br />

Onboard<br />

Energy<br />

storage<br />

Recovered<br />

heat<br />

Waste heat<br />

Usable power<br />

Electrical (net)<br />

Discharge<br />

water<br />

Exhaust gases,<br />

ventilation<br />

EMI, noise,<br />

vibration<br />

The main components are the fuel cell stack, an air processing system (e. g. a compressor<br />

and humidifier), the fuel gas supply, thermal management system etc. Other peripheral components<br />

are valves, pumps, electrical devices etc. <strong>Fuel</strong> like hydrogen (from a tank system)<br />

and air (ambient) are feed into the FCS.<br />

Main FCS inputs are fuel (e.g. hydrogen), air and water, but also electric and thermal power.<br />

Main FCS outputs are the electric net and thermal power, the reactant exhaust gases and<br />

product water. The (electric) gross power is the stack electric power. The difference between<br />

gross and net is the electric power consumed by the parasitic electric components inside the<br />

FCS:<br />

Pnet = Pgross − Pparasitic<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

14


2.1 Anode subsystem 15<br />

2.1 Anode subsystem<br />

Hydrogen is feed into the fuel cell system from a tank system. The consumed hydrogen<br />

inside the fuel cell stack is based of the Faraday equation (equation 1.3) and depending on<br />

the stack load. Actually always more hydrogen is feed into the FCS than is consumed inside<br />

the stack. The relation between hydrogen feed versus consumed hydrogen is called FCS<br />

fuel stoichiometry:<br />

λfuel =<br />

fuel feed<br />

fuel consumed =<br />

H2 feed<br />

≥ 1<br />

H2 consumed<br />

The fuel efficiency (equal to fuel utilization) of a FCS is defined as:<br />

ηfuel =1/λfuel<br />

For many reasons a specific amount of anode off gas needs to exit the fuel cell stack. This<br />

stack anode off gas is finally purged either into the cathode exhaust or directly out of the<br />

FCS. This purged hydrogen is obviously lost for the electrochemical conversion.<br />

It needs to be distinguished between the stack anode and the FCS fuel stoichiometry. For<br />

fuel efficiency reasons the FCS fuel stoichiometry shall be close to 1. But the stack anode<br />

stoichiometry is in the range of 1.1 or 1.6, depending on the stack design and load. This can<br />

be realized e.g. by an anode recirculation system within the anode subsystem.<br />

2.2 Cathode subsystem<br />

An air processing system or cathode submodule is e.g. a compressor and a gas-to-gas<br />

humidifier. Its purpose is to feed the conditioned (humidified) and required amount of air into<br />

the stack.<br />

Ambient air has a specific relative humidity. Depending on the FCS design, this water input<br />

into the FCS may be neglected. More important is the pressure drop inside the stack and<br />

inside the FCS, and therefore the absolute pressure after the compressor and before the<br />

stack. The cathode stoichiometry is depending on the system power level; typical values are<br />

between 1.8 (at higher load) to 3 (or more at low load).<br />

Relative humidity at cathode exhaust In case of PEMFC stacks nearly all product water<br />

is removed via cathode exhaust, mainly as vapor. Assuming complete removal via cathode<br />

exhaust and no water input from ambient air, there is a quite simple relation between cathode<br />

stoichiometry, temperature and pressure of cathode exhaust (for more details see chapter<br />

6).<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


2.3 Coolant subsystem 16<br />

The following equation can be used to estimate the RH at the cathode exhaust at given outlet<br />

pressure pcathode out and temperature T and cathode stoichiometry λcathode:<br />

ϕ =<br />

1<br />

2 · pws(T ) ·<br />

pcathode out<br />

<br />

1+ λcathode<br />

xO 2<br />

where pws(T ) is the saturated water vapor pressure at the cathode outlet temperature T , and<br />

xO2 is the (molar) fraction of O2 in air. The complete derivation of this formula is explained in<br />

chapter 6.<br />

Enthalpy of wet cathode air exhaust The typically fully humidified cathode exhaust gas<br />

of a FCS contains a lot of energy in form of enthalpy (see also section 5.2).<br />

The increasing enthalpy of process air inside the FCS cathode subsystem considers first the<br />

temperature increase (from cold inlet to warm outlet) and second the product water uptake.<br />

As a fist guess the energy loss via stack (not FCS!) cathode exhaust seems to be the difference<br />

between thermal power based on HHV and LHV. But in fact this energy loss is even<br />

higher! This is due to the fact that the air temperature increases inside the stack, while LHV<br />

and HHV are based on the thermodynamic standard temperature T c.<br />

2.3 Coolant subsystem<br />

Coolant (typically liquid, e.g. DI water or WEG) is feed by the coolant pump into the fuel cell<br />

stack. Other peripheral components (e.g. electric converters, compressor, etc.) inside the<br />

FCS may also be cooled in parallel to the stack or serial before or after the stack.<br />

The coolant enters the stack at the stack inlet temperature and leaves the stack at the stack<br />

outlet temperature; leading to a specific temperature increase ΔT depending on stack load.<br />

Typical the temperature increase is ΔT ≤ 10 K. According to given ΔT requirements depending<br />

on stack load the coolant flow needs to be a function of the stack load, too.<br />

The required coolant flow rate ˙ V at a given stack recoverable heat Precoverable heat and coolant<br />

ΔT is calculated as following:<br />

˙V = Precoverable heat<br />

cp · ΔT · ρ<br />

<br />

[ ˙ V ]=l/min<br />

where cp is the specific heat capacity, ΔT = Tcool, out − Tcool, in and ρ the coolant density.<br />

The following table shows the specific heat capacity cp and density ρ of WEG at different<br />

temperatures and mixing ratios (vol%):<br />

Temp.<br />

0°C 20°C 40°C 60°C<br />

80°C<br />

ratio<br />

cp kJ/kg K<br />

ρ<br />

g/cm³<br />

cp<br />

kJ/kg K<br />

ρ<br />

g/cm³<br />

cp<br />

kJ/kg K<br />

ρ<br />

g/cm³<br />

cp<br />

kJ/kg K<br />

ρ<br />

g/cm³<br />

cp<br />

kJ/kg K<br />

ρ<br />

g/cm³<br />

0% 4.218 0.9998 4.182 0.9982 4.179 0.9922 4.184 0.9832 4.196 0.9718<br />

10% 4.09 1.018 4.10 1.011 4.12 1.002 4.13 0.993 4.15 0.983<br />

30% 3.68 1053 3.72 1044 3.76 1034 3.80 1023 3.84 1010<br />

50% 3.28 1.086 3.34 1.075 3.40 1.063 3.46 1.050 3.53 1.036<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


2.4 FCS efficiency 17<br />

Comment: 0% is pure water.<br />

This means that the required coolant volume flow for WEG (50vol%, 60 ◦ C) needs to be 12%<br />

higher compared to pure DI water.<br />

2.4 FCS efficiency<br />

The (electric) efficiency of a fuel cell system is defined as:<br />

ηFCS el =<br />

power out<br />

power in<br />

= electric net power out<br />

fuel power in<br />

= Pnet<br />

Pfuel<br />

“<strong>Fuel</strong> power” Pfuel is the product of the fuel (chemical) energy content based on HHV (or<br />

sometimes LHV) and the fuel feed. For hydrogen as fuel this “fuel power in” is defined as:<br />

Pfuel = HHV · ˙nH2<br />

FCS efficiency can also be exprssed as the product of different (system related) efficiencies<br />

(see also [1], page 718):<br />

with<br />

ηFCS el = ηstack · ηfuel · ηparasitic<br />

ηstack = Ave<strong>Cell</strong><br />

1.253 V , ηfuel = 1<br />

λfuel<br />

and ηparasitic = Pnet<br />

Pgross<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


2.5 Example calculation 18<br />

2.5 Example calculation<br />

Virtual H2/air fuel cell stack with 200 cells and 300 cm 2 active area:<br />

Current density * A/cm2 0.05<br />

Stack electric<br />

0.10 0.20 0.40 0.60 1.00<br />

Ave cell voltage * mV 839 797 756 703 661 588<br />

Current (gross) A 15 30 60 120 180 300<br />

Voltage V 168 159 151 141 132 118<br />

Power (gross) kW el 3 5 9 17 24 35<br />

Stoichiometry * - 3.0<br />

Stack anode<br />

2.0 1.3 1.3 1.3 1.3<br />

Hydrogen flow Nl/min 62.7 83.6 108.7 217.4 326.2 543.6<br />

Hydrogen flow g/sec 0.09 0.13 0.16 0.33 0.49 0.81<br />

Stoichiometry * - 2.2<br />

Stack cathode in<br />

2.0 1.8 1.8 1.8 1.8<br />

Air flow Nl/min 109.5 199.1 358.4 716.8 1075.2 1792.1<br />

Air flow g/sec 2.4 4.3 7.7 15.4 23.2 38.6<br />

Air flow kg/h 8.5 15.4 27.8 55.6 83.4 138.9<br />

P therm LHV kW 1.2 2.7 6.0 13.2 21.3 39.9<br />

P therm HHV kW 1.9 4.1 8.7 18.7 29.5 53.6<br />

delta HHV - LHV kW 0.7 1.4 2.7 5.5 8.2 13.7<br />

Coolant inlet temp * °C 60 60 60 60 60 60<br />

Coolant outlet temp * °C 61 63 66 67 68 70<br />

Coolant delta T K 1 3 6 7 8 10<br />

Coolant flow LHV 2<br />

l/min 17.9 13.1 14.3 27.1 38.3 57.4<br />

Coolant flow HHV 2<br />

Stack thermal<br />

l/min 27.7 19.7 20.8 38.3 53.1 77.0<br />

RH * % 100%<br />

Stack cathode out<br />

100% 100% 100% 100% 100%<br />

pws at coolant outlet temp kPa abs 20.84 22.83 26.12 27.30 28.52 31.12<br />

Pressure out kPa abs 120 120 125 131 137 149<br />

Product water out g/sec 0.3 0.6 1.1 2.2 3.4 5.6<br />

Consumed oxygen g/sec 0.2 0.5 1.0 2.0 3.0 5.0<br />

Dry cathode out g/sec 2 4 7 13 20 34<br />

Wet cathode out g/sec 2 4 8 16 24 39<br />

Enthalpy out kJ/kg 405 445 497 499 500 503<br />

P enthalpy out kW 1 2 3 7 10 17<br />

Stack power in (hydrogen)<br />

Hydrogen feed mol/sec 0.05 0.06 0.08 0.16 0.24 0.40<br />

P chem H2 LHV kW 11 15 20 39 59 98<br />

P chem H2 HHV kW 13 18 23 46 69 116<br />

Stack efficiency (LHV)<br />

Electric efficiency % 67% 64% 60% 56% 53% 47%<br />

<strong>Fuel</strong> efficiency % 22% 32% 46% 43% 41% 36%<br />

* given values<br />

1 20°C and 50% compressor efficiency<br />

2 WEG 50vol% at 60°C<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


3 Appendix 1: Basics<br />

3.1 Thermodynamic basics<br />

The four thermodynamic potentials are:<br />

Internal energy U is the total energy of an thermodynamic system and the sum of all forms<br />

of energies. In an isolated system the internal energy is constant and can not change.<br />

As one result of the first law or thermodynamics the change in the inner energy can be<br />

expressed as the heat supplied to the system minus the work performed by the system:<br />

dU =dq +dw<br />

Free or Helmholtz energy F (or A): is the ”useful” work obtainable from a thermodynamic<br />

system at isothermal and isobaric conditions.<br />

Enthalpy H: The enthalpy is a measure for the energy of a thermodynamic system and the<br />

sum of internal energy and the work for changing the volume: H = U + pV . For each<br />

chemical reaction the entropy change defines the reaction to be endothermic (ΔH 0).<br />

Free or Gibbs enthalpy G: The Gibbs or thermodynamic free enthalpy is the work that a<br />

thermodynamic system can perform: G = H − TS. For each chemical reaction ΔG<br />

defines the reaction to be exergonic (ΔG


3.2 Energy and relevant energy units 20<br />

The following total differentials of the four thermodynamic potentials can be determined:<br />

dU = −pdV + TdS dH = Vdp+ TdS dA = −SdT − pdV dG = Vdp− SdT<br />

How to determine the Maxwell relations?<br />

1. Select two units in the edge of one border, e.g. T and V .<br />

2. Select the corresponding units in the opposite border, here it is −p and −S.<br />

3. Now the Maxwell relation is here: ∂T/∂V = −∂p/∂S<br />

The following four Maxwell relations can be determined:<br />

(∂T/∂V )S = −(∂p/∂S)V<br />

(∂T/∂p)S =(∂V/∂S)p<br />

(∂p/∂T)V =(∂S/∂V )T<br />

(∂V/∂T)p = −(∂S/∂p)T<br />

And finally the following dependencies can be determined by the Guggenheim square:<br />

(∂U/∂S)V = T and (∂U/∂V )S = −p<br />

(∂H/∂S)p = T and (∂H/∂p)S = V<br />

(∂A/∂V )T = −p and (∂A/∂T)V = −S<br />

(∂G/∂p)T = V and (∂G/∂T )p = −S<br />

3.2 Energy and relevant energy units<br />

Energy is the product of power and time: E = P · t<br />

Units for energy:<br />

Joules and kilowatt-hour:<br />

[E]=J=kgm 2 /s 2 =Nm=Ws<br />

1 kWh = 1000 Wh ≡ 3.600.000 Ws = 3.600.000 J = 3.600 kJ = 3.6 MJ<br />

3.3 Temperature dependency of thermodynamic values<br />

Heat capacity of air cp, air of air as a function of temperature ( ◦ C):<br />

T 0 25 50 100 150 200 250 300 350 400 450 500<br />

cp [J/molK] 29.06 29.10 29.13 29.25 29.43 29.67 29.95 30.25 30.58 30.93 31.29 31.64<br />

cp [J/kgK] 1003.37 1004.56 1005.86 1009.91 1016.23 1024.43 1033.96 1044.49 1055.84 1067.87 1080.19 1092.28<br />

Calculated with HSC Chemistry 6.21, air with 78 Vol% N2, 21% O2 and 1% Ar<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


3.4 Standard temperature and pressure 21<br />

Heat capacity of other gases cp of different gases as a function of temperature ( ◦ C):<br />

Molar heat capacity cp [J/molK] vs t [°C]<br />

Species 0 25 50 100 150 200 250 300 350 400 450 500<br />

N2(g) 29.12 29.13 29.14 29.19 29.30 29.47 29.69 29.95 30.24 30.57 30.91 31.26<br />

O2(g) 29.26 29.38 29.50 29.87 30.33 30.83 31.33 31.83 32.31 32.76 33.18 33.56<br />

H2(g) 28.47 29.05 28.90 28.75 28.72 28.77 28.86 28.99 29.13 29.29 29.46 29.64<br />

CO2(g) 36.04 37.12 38.31 40.39 42.19 43.81 45.27 46.61 47.84 48.97 50.01 50.97<br />

H2O(g) 33.56 33.60 33.71 34.04 34.47 34.97 35.50 36.07 36.65 37.25 37.86 38.48<br />

Specific heat capacity cp [J/kgK] vs t [°C]<br />

Species 0 25 50 100 150 200 250 300 350 400 450 500<br />

N2(g) 1039.3 1039.7 1040.3 1042.1 1046.1 1052.2 1060.0 1069.2 1079.6 1091.2 1103.5 1115.9<br />

O2(g) 914.4 918.2 922.0 933.6 947.9 963.4 979.2 994.7 1009.6 1023.7 1036.8 1048.6<br />

H2(g) 14123.8 14409.3 14334.9 14260.3 14247.5 14271.3 14318.2 14380.1 14452.2 14531.3 14615.2 14702.6<br />

CO2(g) 818.9 843.5 870.4 917.7 958.7 995.4 1028.7 1059.1 1087.1 1112.8 1136.4 1158.0<br />

H2O(g) 1863.1 1865.3 1871.0 1889.3 1913.3 1940.9 1970.7 2002.1 2034.6 2067.9 2101.8 2136.2<br />

cp [JJ/mol<br />

K]<br />

50<br />

45<br />

40<br />

35<br />

30<br />

25<br />

20<br />

Calculated with HSC Chemistry 6.21<br />

CO2(g)<br />

H2O(g)<br />

O2(g)<br />

N2(g)<br />

H2(g)<br />

0 50 100<br />

T [°C]<br />

150 200<br />

3.4 Standard temperature and pressure<br />

Standard temperature and pressure (STP) is needed for many fuel cell related calculations;<br />

e.g. to calculate the volumetric reactant flow for a stack. Therefore it seems to be a simple<br />

question to ask for the correct reference temperature and pressure for STP. But the answer<br />

is not simple at all, as the following table shows [6]:<br />

T[ ◦ C] / [K] p abs [kPa] Publishing or establishing entity<br />

0 / 273.15 100.000 IUPAC (present definition)<br />

0 / 273.15 101.325 IUPAC (former definition), NIST, ISO 10780<br />

15 / 288.15 101.325 DIN IEC 62282-3-2 [7]<br />

20 / 293.15 101.325 EPA, NIST<br />

25 / 298.15 101.325 EPA<br />

25 / 298.15 100.000 SATP<br />

Which “standard” is to choose now? To calculate a gas volume flow ˙ V from a molar flow<br />

˙n or mass flow ˙m, the reference temperature and pressure need to be defined, also is mass<br />

flow controllers are used!<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


3.5 HHV and LHV 22<br />

The purpose of Mass flow controllers (MFCs) is to feed a required liquid or gas flow. From<br />

their measurement principle those components do measure a mass flow (e.g. kg/h or g/sec).<br />

But often volumetric values (e.g. l/min or m 3 /h) are more common. To transfer gas mass<br />

flows into gas volumetric flows, the gas density (kg/m 3 ) must be known.<br />

Since the gas density itself is depending on temperature and pressure, a reference temperature<br />

and pressure is needed. Well known MFCs manufacturers like Brooks, Bronkhorst,<br />

Bürckert, Aera or Omega do use the following temperature and pressure as reference for<br />

standard volume flows:<br />

T0 = 273.15 K and p0 = 101.325 kPa<br />

Using such types of MFCs require using this reference temperature and pressure to ensure<br />

correct calculations like described above!<br />

By the way The well known molar volume of an ideal gas is given at this temperature and<br />

pressure:<br />

3.5 HHV and LHV<br />

V0, mol = R · T0<br />

p0<br />

=22.414 ln/mol<br />

The higher heating value (HHV) of any fuel can be measured within a calorimeter. The result<br />

of this measurement is the energy of the chemical (oxidation) reaction starting at 25 ◦ C<br />

and ending at 25 ◦ C; therefore product water is condensed completely. Due to that the HHV<br />

includes the latent heat of water vaporization; but the specific amount of product water produced<br />

by the fuel oxidation reaction needs to be considered.<br />

The lower heating value (LHV) itself can not be measured directly; therefore the LHV needs<br />

to be calculated from HHV minus latent heat of water vaporization.<br />

3.6 Butler-Volmer equation<br />

The Butler-Volmer equation defines the relation between current density j and overpotential<br />

ϕ:<br />

j(ϕ) =j0<br />

<br />

αnF<br />

exp<br />

RT ϕ<br />

<br />

(1 − α)nF<br />

− exp<br />

RT<br />

<br />

ϕ<br />

This is the sum of an anodic and cathodic current j(ϕ) =ja(ϕ)+jc(ϕ) with:<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


3.6 Butler-Volmer equation 23<br />

<br />

αnF<br />

ja(ϕ) =j0 exp<br />

RT ϕ<br />

<br />

Side information: e x − e −x =2sinhx<br />

<br />

(1 − α)nF<br />

jc(ϕ) =−j0 exp<br />

RT<br />

With α =1/2 the Butler-Volmer equation can be dimplified to:<br />

<br />

j(ϕ) 1 nF<br />

=2sinh<br />

2 RT ϕ<br />

<br />

j0<br />

The following chart shows the anodic current (green line), the cathodic current (blue) and the<br />

Butler-Volmer equation itself (red):<br />

current deensity<br />

j [mA/cm²] / j / j0 8<br />

6<br />

4<br />

2<br />

0<br />

-100 -50 0 50 100<br />

-2<br />

-4<br />

-6<br />

-8<br />

overpotential [mV]<br />

In case of low overpotentials (|ϕ| < 10mV , α =1/2) the Butler-Volmer equation simplifies to:<br />

j(ϕ)<br />

j0<br />

= nF<br />

RT ϕ<br />

The following chart shows this linear relation between current density j and overpotential ϕ,<br />

with the slope m = nF/RT :<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

<br />

ϕ


3.6 Butler-Volmer equation 24<br />

j / j 0<br />

0.5<br />

0.4<br />

0.3<br />

0.2<br />

0.1<br />

0.0<br />

-10<br />

-0.1<br />

-5 0 5 10<br />

-0.2<br />

-0.3<br />

-0.4<br />

-0.5<br />

overpotential [mV]<br />

In case of high overpotentials (|ϕ| > 100mV , α =1/2) the Butler-Volmer equation simplifies<br />

to:<br />

ln j(ϕ)<br />

j0<br />

= 1 nF<br />

2 RT ϕ<br />

This relation becomes linear by using a logarithimx y-axes like in the next chart:<br />

ln ( j / j 0)<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

-1<br />

0 50 100 150 200 250 300<br />

-2<br />

-3<br />

-4<br />

overpotential [mV]<br />

The slope of the blue dotted line m =1/2 nF/RT is the Tafel slope in the Tafel equation<br />

ϕ = m · j/j0.<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


4 Appendix 2: Constant values and<br />

abbreviations<br />

Constant values Source<br />

Faraday’s constant F = 96 485.3399 A sec/mol [8]<br />

Molar gas constant R =8.314472 J/K mol [8]<br />

Magnus equation constants C1 = 610.780 Pa<br />

C2 =17.08085<br />

C3 = 234.175 ◦ C<br />

Thermodynamics Source<br />

Standard temperature and pressure T0 = 273.15 K [9]<br />

(STP, see section 3.4) p0 = 101.325 kPa [9]<br />

Molar volume of ideal gases (at STP) V0, mol = RT0/p0 =22.414 ln/mol<br />

Standard ambient T and p Tc = 298.15 K [10]<br />

(SATP) pc = 100.000 kPa [10]<br />

LHV of H2 (at SATP) −ΔHH2O (g) = 241.82 kJ/mol [10], [11]<br />

ˆ=119.96 kJ/g [12]<br />

HHV of H2 (at SATP) −ΔHH2O (l) = 285.83 kJ/mol [10], [11]<br />

ˆ=141.79 kJ/g [12]<br />

Gibbs free enthalpy of H2O (g) (at SATP) −ΔGH2O (g) = 228.57 kJ/mol [10]<br />

Gibbs free enthalpy of H2O (l) (at SATP) −ΔGH2O (l) = 237.13 kJ/mol [10]<br />

Molar weights Source<br />

Molar weight water Mwater =18.0153 g/mol<br />

hydrogen<br />

oxygen<br />

nitrogen<br />

CO2<br />

MH2 =2.01588 g/mol<br />

MO2 =31.9988 g/mol<br />

MN2 =28.01348 g/mol<br />

MCO2 =44.0095 g/mol<br />

[8]<br />

[8]<br />

[8]<br />

[8]<br />

air Mair =28.9646431 g/mol [8]<br />

Molar fraction of O2 in air xO2 =0.21<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

25


4.1 Relevant units based on SI units 26<br />

Other relevant constants Source<br />

Individual gas constant of air Rair = R/Mair = 287.06 J/kg K<br />

Individual gas constant of water vapor Rw = R/Mw = 461.52 J/kg K<br />

Density of air (at STP) ρair =1.293 kg/m 3 n<br />

Density of H2 (at STP) ρH2 =0.0899 kg/m3 n<br />

Specific heat capacity of water (20 ◦ C) cp, m, water = 4182 J/kg K<br />

Density of water (20 ◦ C) ρwater = 998.2 kg/m 3<br />

Specific heat capacity of air (p = const) cp, m, air = 1005.45 J/kg K<br />

Specific heat capacity of air (V = const) cV, m, air = cp, m, air − Rair<br />

= 718.39 J/kg K<br />

Ratio of specific heats for air κ = cp/cV =1.40 or (κ − 1)/κ<br />

=0.285<br />

Specific heat capacity of water vapor cp, water = 1858.94 J/kg K<br />

Enthalpy of water vaporization (0 ◦ C) hwe = 2500.827 J/g<br />

4.1 Relevant units based on SI units<br />

Physical unit Unit name and symbol in SI unit in non SI units<br />

Force F Newton (N) kg m/s 2 -<br />

Pressure p Pascal (Pa) kg/(m s 2 ) N/m 2<br />

Energy/work E/W Joule (J) kg m 2 /s 2 Nm, Pa · m 3<br />

Power P Watt (W) kg m 2 /s 3 J/s<br />

Charge Q Coulomb (C) As -<br />

Voltage U Volt (V) kg m 2 /(s 3 A) W/A, J/C<br />

Resistance R Ohm (Ω) kg m 2 /(s 3 A 2 ) V/A<br />

4.2 Used abbreviations<br />

FCS <strong>Fuel</strong> cell system<br />

LHV Lower heating value<br />

HHV Higher heating value<br />

OCV Open circuit voltage<br />

EMF Electromotive force<br />

Nl (or ln), Nm 3 (or m 3 n) Norm liter or norm cubic meter<br />

(volume normalized to SATP)<br />

RH Relative humidity<br />

STP Standard temperature and pressure<br />

SATP Standard ambient temperature and pressure<br />

TD Thermodynamic<br />

WEG Water ethylene glycol<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5 Appendix 3: Air<br />

5.1 Moist air<br />

Water vapor and saturation pressure in moist air The water vapor partial pressure at<br />

saturation pws(t) is a function of temperature t [ ◦ C]. Its values are documented in tables (e.<br />

g. in [13]), but also a couple of equations allow its calculation. The most popular one is the<br />

Magnus equation, but others fit with a higher accuracy to the table values (e.g. equation with<br />

ten parameters in the documentation of Vaisalla products).<br />

Magnus equation:<br />

Water vapor saturration<br />

pressure [kPa]<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

pws(t) =C1 · exp C2 · t<br />

C3 + t<br />

t = C3 · ln pws(t)<br />

C1<br />

C2 − ln pws(t)<br />

C1<br />

[pws(t)] = Pa, [t] = ◦ C<br />

0 10 20 30 40 50 60 70 80 90 100<br />

Temperature t [°C]<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

27


5.1 Moist air 28<br />

Specific humidity or humidity (mixing) ratio Specific humidity Y is the ratio between the<br />

actual mass of water vapor mw in moist air to the mass of the dry air mdry air.<br />

Y (t) = mw<br />

mdry air<br />

= Rair<br />

Rw<br />

pw(t)<br />

·<br />

pa − pw(t)<br />

= Mw<br />

Mair<br />

pw(t)<br />

·<br />

pa − pw(t) =0.622·<br />

pw(t)<br />

pa − pw(t)<br />

[Y (t)] = kg/kg<br />

The maximum amount of water vapor in the air is achieved when p w(t) =pws(t) the saturation<br />

pressure of water vapor at the temperature t.<br />

For other gases the molar weight has to be considered in the equation above. The constant<br />

value 0.622 is only valid for moist air!<br />

Since the water vapor pressure is small regarding to the atmospheric pressure, the relation<br />

between the humidity ratio and the saturation pressure is almost linear at temperature far<br />

below 100 ◦ C.<br />

Specific humidity at a saturation Ysat [kg/kg]<br />

Specific hummidity<br />

Y [kg/kg]<br />

2.0<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.0<br />

2.0<br />

1.8<br />

1.6<br />

1.4<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

0.2<br />

0.0<br />

101.3 kPa<br />

120 kPa<br />

150 kPa<br />

200 kPa<br />

RH is 100% (saturation)<br />

0 20 40 60 80 100<br />

Temperature t [°C]<br />

absolute pressure is 101.325 kPa<br />

100% RH<br />

75% RH<br />

50% RH<br />

25% RH<br />

0 20 40<br />

Temperature t [°C]<br />

60 80 100<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.1 Moist air 29<br />

Relative humidity RH (or ϕ) is the ratio of the partial pressure of water vapor pw(t) to the<br />

partial pressure of water vapor at saturation pws(t):<br />

RH can also be calculated with Y (t):<br />

ϕ = pw(t) aw(t) mw<br />

= =<br />

pws(t) aws(t) mws<br />

ϕ =<br />

Y (t)<br />

·<br />

Mw + Y (t) Mair<br />

p<br />

ps(t) =<br />

ϕ =0.0 − 1.0<br />

Y (t)<br />

0, 622 + Y (t) ·<br />

p<br />

ps(t)<br />

Absolute humidity or water vapor density Absolute humidity a(t) is the actual mass of<br />

water vapor present in the moist air and a function of t:<br />

a(t) = Mw<br />

R<br />

aturation asat [g/m3 absolute humidity at sa<br />

]<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

0<br />

pw(t) 1<br />

· =<br />

T0 + t Rw(t) ·<br />

pw<br />

K pw(t)<br />

=2.167g ·<br />

T0 + t J T0 + t<br />

RH is 100% (saturation)<br />

[a(t)] = g/m 3 , [t] = ◦ C<br />

0 20 40 60 80 100<br />

Temperature [°C]<br />

Molar fraction The molar fraction y(t) of water vapor is calculated as:<br />

y(t) = pw(t)<br />

pa<br />

y =0.0 − 1.0<br />

At standard pressure and 100 ◦ C y = 1 because there is only water in vapor phase (and no<br />

air).<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.1 Moist air 30<br />

Mol fraction<br />

y<br />

1.0<br />

0.9<br />

0.8<br />

0.7<br />

0.6<br />

0.5<br />

0.4<br />

0.3<br />

0.2<br />

0.1<br />

0.0<br />

1E-2<br />

1E-4<br />

1E-6<br />

1E-8<br />

-100 -80 -60 -40 -20 0<br />

101.325 kPa<br />

120 kPa<br />

150 kPa<br />

200 kPa<br />

0 20 40 60 80 100 120<br />

Dew point temperature Tdp [°C]<br />

Dew point temperature The dew point temperature (DPT) T dp is the temperature at which<br />

water vapor starts to condense out of the air, the temperature at which air becomes completely<br />

saturated. Above this temperature the moisture will stay in the air.<br />

If the DPT is close to the air temperature, the relative humidity is high, and if the dew point is<br />

well below the air temperature, the relative humidity is low.<br />

Tdp =<br />

<br />

C3 · ln ϕ + C2·t<br />

<br />

C3+t<br />

C2 − ln ϕ − C2·t<br />

C3+t<br />

To calculate RH from temperature and DPT:<br />

ϕ = pw(t)<br />

pws(t)<br />

= exp C2·Tdp<br />

C3+Tdp<br />

exp C2·t<br />

C3+t<br />

[Tdp] = ◦ C<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.1 Moist air 31<br />

Dew point temmperature<br />

[°C]<br />

relative hummidity<br />

RH [%]<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

-20<br />

100%<br />

90%<br />

80%<br />

70%<br />

60%<br />

50%<br />

40%<br />

30%<br />

20%<br />

10%<br />

0%<br />

100% RH<br />

80% RH<br />

60% RH<br />

40% RH<br />

20% RH<br />

0 20 40 60 80 100<br />

Temperature t [°C]<br />

DPT = t - 2K<br />

DPT = t - 5K<br />

DPT = t - 10K<br />

DPT = t - 20K<br />

0 20 40 60 80 100<br />

Temperature t [°C]<br />

Enthalpy The air enthalpy h is needed to calculate energy and power of air. The enthalpy<br />

of moist air consists of sensible heat and latent heat. Since moist air is a mixture of dry air<br />

and water vapor, the enthalpy includes the enthalpy of the dry air (the sensible heat h air) and<br />

the enthalpy of the evaporated water (the latent heat hwater).<br />

Specific enthalpy h [kJ/kg] of moist air is defined as the total enthalpy of the dry air and the<br />

water vapor mixture per kg of moist air.<br />

The enthalpy consists of three parts: a) warming up dry air from the reference temperature<br />

to the air temperature t, b) evaporating water inside the moist air and c) warming up water<br />

vapor from the reference temperature to the air temperature t:<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.1 Moist air 32<br />

with<br />

h = hair + Y · hwater<br />

hair = cp, air · t and hwater = cp, water · t + hwe<br />

h = cp, air · t + Y · (cp, water · t + hwe) [h] =J/g<br />

(5.1)<br />

where Y is the specific humidity of moist air, cp, air is the specific heat capacity of dry air,<br />

cp, water is the specific heat capacity of water vapor and hwe is the specific enthalpy of water<br />

vaporization. In case of dry air (Y =0), the enthalpy is a linear function of temperature (with<br />

slope cp, air). Heat capacities are depending on temperature (see chapter 3.3), but between<br />

0 and 100 ◦ C this may be neglected.<br />

Because the enthalpy is not an absolute value; only the enthalpy difference to a reference<br />

temperature can be calculated. Depending on the unit of temperature, the reference temperature<br />

is 0◦Cif[t] = ◦C;or0Kif[t] =K. If the temperature is given in ◦C, the enthalpy is 0 kJ<br />

kg<br />

at 0◦C. If temperature is given in K, the enthalpy is 0 kJ<br />

kg at 0 K.<br />

Due to the fact that only the enthalpy difference is used, it doesn’t mater if temperature is<br />

given in K or ◦ C! It’s just important not to switch between both units.<br />

The following chart show the enthalpy based on 0 ◦ C reference:<br />

Specific entthalpy<br />

h [kJ/kg]<br />

500<br />

450<br />

400<br />

350<br />

300<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0<br />

100% RH<br />

75% RH<br />

50% RH<br />

25% RH<br />

dry (0%)<br />

absolute pressure is 101.325 kPa<br />

0 10 20 30 40 50 60 70 80 90 100<br />

Temperature t [°C]<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.2 Energy and power of air 33<br />

Specific enthhalpy<br />

h [kJ/kg]<br />

2000<br />

1800<br />

1600<br />

1400<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

0<br />

relative humidity is 100% (saturation)<br />

101.325 kPa<br />

120 kPa<br />

150 kPa<br />

200 kPa<br />

0 10 20 30 40 50 60 70 80 90 100<br />

Temperature t [°C]<br />

For dry air there is another empirical fit to calculate the enthalpy. This equation is used in<br />

DIN IEC 62282-3-2 [7]:<br />

h(t) =(A · t + B · t 2 + C · t 3 )/Mair<br />

with A =27.434, B=6.18/2000, C= −0.8987/3 · 10 6 .<br />

[h(t)] = kJ/kg, [t] = ◦ C or K<br />

Also here the temperature t can be given in ◦ C or K, see above. But this equation is only<br />

valid for dry air!<br />

5.2 Energy and power of air<br />

Energy and power of dry and wet are important to calculate e.g. the power demand for air<br />

humidification in a fuel cell system or to calculate efficiencies. See also ASME PTC 50-2002<br />

<strong>Fuel</strong> <strong>Cell</strong> Power Systems Performance [14] and DIN IEC 62282-3-2 <strong>Fuel</strong> cell technologies -<br />

Part 3-2: Stationary fuel cell power systems [7].<br />

The energy of air contains the air enthalpy and the pressure:<br />

The air power is given as:<br />

Eair = hair + Ep, air<br />

Pair = Eair · ˙mair<br />

[Eair] =kJ/kg<br />

[Pair] =kW<br />

The air enthalpy hair is defined by equation 5.1. Please be aware that always enthalpy<br />

differences are calculated and not the absolute enthalpy!<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 34<br />

The energy of compressed air is given by:<br />

Ep, air = Rair · T0 · ln p<br />

T0 and p0 are the reference temperature and pressure, see section 3.4.<br />

Example 1: How much power is required to heat dry air from 20 to 60 ◦ C with a mass flow<br />

of 30 kg/hr?<br />

Δh = h 60 ◦ C/0% − h 20 ◦ C/0% =40.218 kJ/kg<br />

P =Δh · ˙mair =40.218 kJ/kg · 30 kg/hr ·<br />

p0<br />

1<br />

hr/sec = 335 W<br />

3600<br />

Example 2: How much power is required to heat and humidify air at ambient pressure from<br />

20 ◦ C and 50% RH to 60 ◦ C and 80% RH? Air mass flow is 30 kg/hr.<br />

h 20 ◦ C/50% =38.56 kJ/kg<br />

h 60 ◦ C/80% = 363.18 kJ/kg<br />

Δh = 326.61 kJ/kg<br />

P =Δh · ˙mair = 326.61 kJ/kg · 30 kg/hr ·<br />

5.3 Air compression<br />

5.3.1 Definitions<br />

1<br />

hr/sec = 2, 722 W<br />

3600<br />

Adiabatic Process where no heat is transferred to or from the surroundings (dq = 0).<br />

Reversible Process can be reversed without loss or dissipation of energy (dS = 0).<br />

Isentropic Process with equal entropy<br />

Any reversible adiabatic process is an isentropic process (dq = dS = 0). But not vice versa!<br />

See also [15].<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 35<br />

5.3.2 Thermodynamics<br />

Compression and expansion<br />

A gas mass flow ˙m1 is compressed or expanded<br />

from pressure p1 and temperature T1 to pressure<br />

p2 and temperature T2. p2 >p1 in case of compression<br />

and p2 1 and for expansion Π < 1.<br />

A compression process consumes energy or<br />

work, an expansion process produces energy or work.<br />

Gas in<br />

W el<br />

Compressor<br />

W loss<br />

Gas out<br />

To calculate the efficiency of a compression process the theoretical energy demand needs to<br />

be calculated based on an isentropic process. In a real compression process there is always<br />

heat transferred to the surrounding (or cooling), and also gas mass flow losses can occur<br />

inside the compressor.<br />

Thermodynamic of gases<br />

Internal energy U The first law of thermodynamics [10] defines infinitesimal changes in<br />

internal energy dU of an ideal gas as changes in added heat dq and provided work dw:<br />

dU =dq +dw<br />

Enthalpy H is defined as H = U + pV . Infinitesimal changes dH are therefore defined as:<br />

dH =dU + pdV + V dp<br />

Heat capacities C describe the temperature dependencies of internal energy U and enthalpy<br />

H:<br />

CV =(∂U/∂T)V<br />

Cp =(∂H/∂T)p<br />

CV is the heat capacity at constant volume and Cp the heat capacity at constant pressure of<br />

an ideal gas:<br />

dU = CVdT and dH = CpdT (5.2)<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 36<br />

With pV = nRT it is dH =dU + nRdT and therefore:<br />

Cp − CV = nR<br />

For ideal gases the specific heat capacities cp and cV with [c] =J/mol K are independent of<br />

temperature! For ideal one atomic gases it ist:<br />

cp = Cp<br />

n<br />

And for ideal two atomic gases:<br />

5<br />

=<br />

2 R cV = CV<br />

n<br />

3 5<br />

= R κ =<br />

2 3 =1.67<br />

cp = 7<br />

2 R cV = 5 7<br />

R κ =<br />

2 5 =1.40<br />

The specific heat capacities cp, m and cV, m are given as:<br />

cp, m = cp/M and cV, m = cV/M [cp, m] =[cV, m] =J/kg K<br />

Polytropic process For all thermodynamic processes of ideal gases it is in general:<br />

pV n = const n = polytropic index (constant)<br />

The energy or work in a volume change process is in general:<br />

With pV = nRT it is:<br />

dw =dU = −p dV = CV dT<br />

CV dT/T = −nR dV/V<br />

The integral over start (1) and end state (2) is:<br />

CV<br />

2<br />

1<br />

dT/T = −nR<br />

2<br />

1<br />

dV/V<br />

CV ln (T2/T1) =−nR ln (V2/V1)<br />

Isentropic process The isentropic process is a special case of a polytropic process, where<br />

the polytropic index becomes the isentropic index or heat capacity ratio κ:<br />

n = κ = cp<br />

cV<br />

> 1<br />

With cp − cV = R, cV = CV/n and therefore CV cV<br />

nR = cp−cV<br />

1 = κ−1 it is:<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 37<br />

T1<br />

T2<br />

=<br />

κ−1 V2<br />

The following ratios are valid for an isentropic process:<br />

T1<br />

T2<br />

=<br />

κ−1 V2<br />

V1<br />

Volume work and technical work<br />

T1<br />

T2<br />

=<br />

V1<br />

p1<br />

p2<br />

κ−1<br />

κ<br />

p1<br />

p2<br />

=<br />

κ<br />

V2<br />

The volume (change) work wV,12 is the work that is done on a piston to reduce the start<br />

volume V1 to the end volume V2. It is equivalent in the change of inner energy. The volume<br />

work for an adiabatic process (dq =0) is defined as:<br />

V2<br />

wV, 12 = −<br />

V1<br />

p dV =<br />

2<br />

1<br />

dU = CV<br />

T2<br />

T1<br />

V1<br />

dT = CVΔT<br />

The technical work wt,12 is the work that is transferred from or mass flow via a technical<br />

system (for instance a mechanical axle). The technical work is equal to the enthalpy of the<br />

kinetic and potential energy of a stationary mass flow. The technical work wt,12 for compression<br />

is the work given to the drive shaft of the compressor; it contains the displacement work,<br />

but not the friction [16]!<br />

The technical work for an adiabatic process (dq =0) are defined as:<br />

p-V-chart<br />

p2<br />

wt, 12 =+<br />

p<br />

p2<br />

p1<br />

p1<br />

V dp =<br />

2<br />

V2<br />

2<br />

1<br />

dH = CpΔT<br />

Each compression process (polytropic, isentropic, isothermal etc.) follows a (similar but not<br />

the same) curve the pV chart from the start (1) to the end (2) point. Adding the different<br />

process areas shown in the pV chart gives:<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

V1<br />

1<br />

V


5.3 Air compression 38<br />

Therefore:<br />

V1<br />

p2V2 +<br />

V2<br />

p2<br />

p dV = p1V1 + V dp<br />

p1<br />

wt, 12 = wV,12 + p2V2 − p1V1<br />

Comment: For liquids ΔV ≈ 0 and therefore wV, 12 ≈ 0; then it is: wt, 12 ≈ (p2 − p1) · V<br />

The thermodynamic derivation (see above) defines the following ratios for the isentropic<br />

compression or expansion:<br />

Π=<br />

κ V1<br />

V2<br />

Therefore for the volume work it is:<br />

And similar for the technical work:<br />

and<br />

T1<br />

T2<br />

=<br />

κ−1 V2<br />

V1<br />

=Π κ−1<br />

κ<br />

<br />

wV, 12 = cV, m · (T2 − T1) =cV, m T1 · Π κ−1 <br />

κ − 1<br />

<br />

wt, 12 = cp, m · (T2 − T1) =cp, m T1 · Π κ−1 <br />

κ − 1<br />

wt, 12 = h2 − h1 with h = cp, m · T<br />

wt, 12 = κ · wV, 12 with κ = cp/cV<br />

The technical work is always more than the volume work, because κ>1.<br />

5.3.3 Ideal and real compressor<br />

Ideal The ideal compression is an isentropic process. There is no (energy or air mass flow)<br />

exchange with the surroundings.<br />

Real Due to friction the gas compression in a real compressor always dissipates energy to<br />

the surroundings or to the cooling system. This compression process is polytropic. After a<br />

polytropic compression the actual end temperature T2, act is always higher compared to an<br />

ideal isentropic compression T2, s:<br />

T2, act >T2, s<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 39<br />

The isentropic efficiency ηs of a compressor is the ratio between isentropic technical work<br />

ws, 12 and actual technical work wact, 12:<br />

ηs = ws, 12<br />

wact, 12<br />

= T2, s − T1<br />

T2, act − T1<br />

wact, 12 is ws, 12 plus specific friction work (dessipitation).<br />

= h2, s − h1<br />

h2, act − h1<br />

To calculate the isentropic work, first of all the isentropic end temperature T2, s needs to be<br />

calculated:<br />

T2, s = T1 · Π κ−1<br />

κ<br />

Now the isentropic technical work can be calculated as:<br />

<br />

ws, 12 = cp, m · (T2, s − T1) =cp, m T1 · Π κ−1 <br />

κ − 1<br />

For dry air at room temperature (25 ◦ C) the isentropic work ws, 12 as a function of pressure<br />

ratio Π looks as following:<br />

Isentropic work w [kJ/kg]<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

1.0 1.5 2.0 2.5 3.0 3.5 4.0<br />

Finally the isentropic power of compression is:<br />

Pressure ratio P [-]<br />

Ps, 12 = ˙m · ws, 12<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 40<br />

5.3.4 Examples<br />

Example 1: Isentropic efficiency<br />

Air is compressed from 1 bara at 30 ◦ C (303.15 K) to 3 bara at 150 ◦ C (423.15 K). In the<br />

compressor there is no energy or air mass flow loss to the surroundings.<br />

The actual technical work that is done at the air is:<br />

Isentropic temperature:<br />

wact = cp, m · (T2, act − T1) = 1005<br />

T2, s = T1 · Π κ−1<br />

κ = 303.15 K ·<br />

Isentropic technical work:<br />

Isentropic efficiency:<br />

ws = cp, m · (T2, s − T1) = 1005<br />

ηs = ws<br />

wact<br />

Example 2: Electric efficiency<br />

= 112.4 kJ/kg<br />

J<br />

kJ<br />

· 120 K = 120.6<br />

kg · K kg<br />

0.285 3bara<br />

= 414.6K or 141.5<br />

1bara<br />

◦ C<br />

J<br />

kJ<br />

· (414.6K− 303.15 K) = 112.4<br />

kg · K kg<br />

120.6 kJ/kg<br />

=0.932 or 93.2%<br />

27 kg/h air is compressed from 2.4 to 6 barabs, the electric power consumption of the compressor<br />

is 1305 W:<br />

˙m =27kg/h, p1 =2.4 barabs and T1 =18 ◦ = 291K<br />

p2 = 6 barabs and Pel = 1305 W<br />

Air mass flow losses due to gaps and other heat losses to the surroundings are neglected!<br />

But of course heat is transferred to the cooling!<br />

The isentropic technical work given to the air is:<br />

<br />

ws = cp, m T1 · Π κ−1 <br />

κ − 1 = 1005<br />

Isentropic technical power:<br />

<br />

0.285<br />

J<br />

6bar<br />

· 291 K ·<br />

− 1 =87.6<br />

kg · K 2.4bar<br />

kJ<br />

kg<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


5.3 Air compression 41<br />

Ps = ˙m · ws =87.6 kJ<br />

· 27 kg/h = 2365.2 kJ/h = 657.0 W<br />

kg<br />

The electric efficiency of this compressor is:<br />

5.3.5 Comment<br />

ηel = Ps<br />

Pel<br />

= 657.0 W<br />

1305 W<br />

=0.50 or 50%<br />

The technical work equation is often given in literature with different indices. The next two<br />

equations show the relation between κ, R, cp and cV:<br />

κ cp/cV<br />

· R =<br />

κ − 1 cp/cV − 1 · (cp − cV) =<br />

1<br />

· R =<br />

κ − 1<br />

cp<br />

cp − cV<br />

· (cp − cV) =cp<br />

1<br />

cp/cV − 1 · (cp − cV) = cV<br />

· (cp − cV) =cV<br />

cp − cV<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


6 Appendix 4: <strong>Fuel</strong> cell stack water<br />

management<br />

6.1 Assumptions<br />

Simple calculation of fuel cell stack water management, based on calculation of RH at cathode<br />

exhaust with the following assumptions:<br />

1. The product water is removed via cathode side; that means there is no water removal<br />

via anode side.<br />

2. Cathode air is heated inside the stack to a specific temperature t (which does not<br />

necessarily have to be the stack coolant outlet temperature).<br />

3. Condensation is not considered! All water leaves the stack as water vapor.<br />

4. There is no water input via anode or cathode into the stack. That means that cathode<br />

air and hydrogen at stack inlet are dry.<br />

5. All gases (air, hydrogen, water vapor) are treated as ideal gases.<br />

6.2 Derivation 1 (via volume flow and absolute humidity)<br />

Product water (PW) ˙mw = 1<br />

Volume flow PW (=H2)<br />

2F · Mw<br />

Vw(t, ˙ p) =<br />

[˙mw] =g/Asec<br />

1<br />

2F · Vm(t, p) [ ˙ Vw] =m3 Volume flow O2<br />

˙VO2<br />

1 (t, p) = 4F<br />

/Asec<br />

· Vm(t, p) [ ˙ VO2 ]=m3 Air volume flow<br />

/Asec<br />

˙ Vair(t, p, λ, x) = ˙ λ<br />

VO2 (t, p) · x [ ˙ Vair] =m3 /Asec<br />

Volume flow at cathode exhaust (less consumed oxygen, plus product water vapor):<br />

˙Vout(t, p, λ, x) = ˙ Vair(t, p, λ, x) − ˙ VO2 (t, p)+ ˙ Vw(t, p) = 1<br />

4F Vm(t,<br />

<br />

λ<br />

p) · − 1+2<br />

x<br />

[ ˙ Vout] =m 3 /Asec<br />

Absolute humidity at cathode inlet (assumption!): ain =0g/m 3<br />

Absolute humidity at cathode outlet:<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza<br />

42


6.3 Derivation 2 (via mass flow and specific humidity) 43<br />

aout(t, p, λ, x) =<br />

Relative humidity at cathode outlet:<br />

Simplification of deviation 1<br />

˙mw<br />

+ ain [aout]<br />

˙Vout(t, p, λ, x)<br />

φ(t, p, λ, x) = aout(t, p, λ, x)<br />

as(t)<br />

=g/m 3<br />

φ =0.0 − 1.0<br />

This calculation can be combined and simplified to the following formula:<br />

Or in other terms:<br />

φ(t, p, λ, x) =<br />

1/2F ·Mw<br />

1/4F ·Vm(t,p)·(λ/x+1)<br />

Mw/R · ps(t)/t + T0<br />

ϕ =<br />

1<br />

2 · pws ·<br />

pcathode out<br />

<br />

=<br />

1+ λcathode<br />

xO 2<br />

2<br />

λ/x +1 ·<br />

p<br />

ps(t)<br />

For the dew point temperature this calculation can be simplified to the following formula<br />

(which is independent of temperature t!):<br />

Tdp(p, λ, x) = C3 · ln K(p, λ, x)<br />

C2 − ln K(p, λ, x)<br />

<br />

p<br />

with K(p, λ, x) = 1<br />

2 · C1 · 1+ λ<br />

<br />

x<br />

6.3 Derivation 2 (via mass flow and specific humidity)<br />

˙mair in = 1<br />

4F · Mair · λ<br />

· I<br />

x<br />

˙mw = 1<br />

2F · Mw · I<br />

˙mO2 consumed = 1<br />

4F<br />

· MO2 · I<br />

˙mcathode dry out = ˙mair in − ˙mO2 consumed = 1<br />

4F<br />

The specific humidity at cathode outlet is:<br />

· Mair<br />

<br />

λ<br />

x − M <br />

O2<br />

· I<br />

Mair<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


6.4 Conclusion 44<br />

Y =<br />

˙mw<br />

˙mcathode dry out<br />

And the relative humidity at cathode outlet is then:<br />

φ =<br />

Y<br />

·<br />

Mw + Y Mair<br />

6.4 Conclusion<br />

p<br />

ps(t) =<br />

Y<br />

0.622 + Y ·<br />

2 · Mw<br />

= <br />

λ<br />

Mair · x − M 2 · 0.622<br />

= <br />

O λ<br />

2<br />

Mair<br />

x − 1.105<br />

p<br />

ps(t) =<br />

With this simplified model for the cathode exhaust . . .<br />

2<br />

·<br />

λ<br />

x +0.895<br />

p<br />

ps(t) =<br />

p<br />

1<br />

2 · ps(t) 0.895 + λ<br />

x<br />

1. . . . the relative humidity is a function of temperature, pressure and stoichiometry.<br />

2. . . . the dew point temperature is a function of pressure and stoichiometry (and independent<br />

of temperature)!<br />

There both derivations 1 and 2 are coming nearly to the same result; with one minor difference:<br />

The ”1” in derivation 1 is ”0.895” in derivation 2.<br />

I currently really don’t know in which derivation there is an error (in reasoning). But this<br />

failure is not too significant, because λ/x ≫ 1.<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


Bibliography 45<br />

Bibliography<br />

[1] Arnold Lamm Wolf Vielstich and Hubert A. Gasteiger. Handbook of <strong>Fuel</strong> <strong>Cell</strong>s Vol. 1.<br />

John Wiley & Sons Ltd, 1 edition, 2003.<br />

[2] U.S. Department of Energy. <strong>Fuel</strong> <strong>Cell</strong> Handbook. National Technical Information Service,<br />

U.S. Department of Commerce, 7 edition, 2004.<br />

[3] James Larminie and Andrew Dicks. <strong>Fuel</strong> <strong>Cell</strong> Systems Explained. John Wiley & Sons<br />

Ltd, 2 edition, 2004.<br />

[4] Performance Working Group within the SAE <strong>Fuel</strong> <strong>Cell</strong> Standards Committee. SAE<br />

J2617: Recommended Practice for testing Performance of PEM <strong>Fuel</strong> <strong>Cell</strong> Stack Subsystem<br />

for Automotive Applications. SAE International, Nov2007.<br />

[5] <strong>Fuel</strong> <strong>Cell</strong> Technologies BSI Technical Committee GEL/105. DD IEC TS 62282-1:2005<br />

<strong>Fuel</strong> cell technologies - Part 1: Terminology. BSI British Standards, 18 April 2005.<br />

[6] Wikipedia. Standard conditions for temperature and pressure.<br />

http://en.wikipedia.org/wiki/Standard conditions for temperature and pressure, July<br />

2010.<br />

[7] DIN. DIN IEC 62282-3-2 <strong>Fuel</strong> cell technologies - Part 3-2: Stationary fuel cell power<br />

systems. DIN Deutsches Institut fuer Normung e. V., July 2009.<br />

[8] http://physics.nist.gov/cuu/Constants/index.html. NIST Fundamental Physical Constants.<br />

[9] DIN. DIN 1343 Reference conditions, normal conditions, normal volume; concepts and<br />

values. DIN Deutsches Institut fuer Normung e. V., 1990.<br />

[10] Peter W. Atkins. Physikalische Chemie, volume 2. VCH Verlagsgesellschaft GmbH,<br />

1990.<br />

[11] DIN. DIN 51857 Gaseous fuels and other gases - Calculation of calorific value, density,<br />

relative density and Wobbe index of pure gases and gas mixtures. DIN Deutsches<br />

Institut fuer Normung e. V., 1990.<br />

[12] SAE. SAE J2572: Recommended Practice for Measuring <strong>Fuel</strong> Consumption and Range<br />

of <strong>Fuel</strong> <strong>Cell</strong> and Hybrid <strong>Fuel</strong> <strong>Cell</strong> Vehicles <strong>Fuel</strong>led by Compressed Gaseous Hydrogen.<br />

SAE International, 2008-10.<br />

[13] David R. Lide. CRC Handbook of Chemistry and Physics. CRC Press, 1990.<br />

[14] A. J. Leo (Chair). ASME PTC 50-2002 <strong>Fuel</strong> <strong>Cell</strong> Power Systems Performance. The<br />

American Society of Mechanical Engineers, November 29, 2002.<br />

[15] http://www.wikipedia.org/. Wikipedia.<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza


Bibliography 46<br />

[16] Prof. Dr. Dieter Winklmair. Script Energie- und Wärmechnik,<br />

http://www.winklmair.de/ewt/folien-1.pdf, August 2010.<br />

<strong>Fuel</strong> <strong>Cell</strong> <strong>Formulary</strong> February 27, 2012 c○ Alexander Kabza

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!