Vicinity Property No. CA-401<br />
Outdoor gamma readings in the excavated area ranged from 11<br />
to 13 micro R/hr. The readings are given in Table 3.2.<br />
Drawings CA-401-020, CA-401-021, and CA-401-022 show the<br />
actual areas <strong>of</strong> excavation.<br />
These results confirm that exterior contamination has been<br />
reduced to levels below the EPA standards for radium in<br />
soil. Background for the Canonsburg site is 8 to 11 micro<br />
R/hr and 1.2 pCi/g.<br />
Interior:<br />
Remedial action was performed indoors only in Building 14A<br />
on this property. A gamma scan in the excavated regions<br />
showed gamma levels up to a maximum <strong>of</strong> 12 micro R/hr, which<br />
is less than the EPA standard <strong>of</strong> background plus 20 micro<br />
R/hr. These results are described in Table 3.2.<br />
"Grab" radon daughter concentration (RDC) measurements were<br />
made in 4 locations, as described in Table 3.4. These<br />
measurements were made under standard conditions as<br />
described in the VPMIM. Measurements were not made in<br />
Building 14A as close-up conditions cannot be met.<br />
3.2 Recommendation for Certification<br />
3.2.1 Exterior:<br />
3.2.2 Interior:<br />
Fourteen areas <strong>of</strong> contamination were identified and<br />
removed. Soil samples after excavation and prior to<br />
backfilling indicate that the limits <strong>of</strong> 5 pCi/g in the<br />
surface 15 cm. and 15 pCi/g in any 15 cm. layer below the<br />
surface are not exceeded. Based on this information, we<br />
recommend that the exterior <strong>of</strong> this vicinity property be<br />
certified to be in compliance with EPA standards for the<br />
UNTRA Project.<br />
Remedial action was conducted in the structure. All gammu<br />
readings taken in the structure following remedial action<br />
were less than the 20 micro R/hr above background limit.<br />
Radon daughter concentrations are below the 0.01 WL limit<br />
for grab samples. Based on this information, we reconmend<br />
that the interior be certified to be within the limits <strong>of</strong><br />
the EPA standards for the UNTRA Project.<br />