Vicinity Property No. CA-401<br />

Outdoor gamma readings in the excavated area ranged from 11<br />

to 13 micro R/hr. The readings are given in Table 3.2.<br />

Drawings CA-401-020, CA-401-021, and CA-401-022 show the<br />

actual areas <strong>of</strong> excavation.<br />

These results confirm that exterior contamination has been<br />

reduced to levels below the EPA standards for radium in<br />

soil. Background for the Canonsburg site is 8 to 11 micro<br />

R/hr and 1.2 pCi/g.<br />

Interior:<br />

Remedial action was performed indoors only in Building 14A<br />

on this property. A gamma scan in the excavated regions<br />

showed gamma levels up to a maximum <strong>of</strong> 12 micro R/hr, which<br />

is less than the EPA standard <strong>of</strong> background plus 20 micro<br />

R/hr. These results are described in Table 3.2.<br />

"Grab" radon daughter concentration (RDC) measurements were<br />

made in 4 locations, as described in Table 3.4. These<br />

measurements were made under standard conditions as<br />

described in the VPMIM. Measurements were not made in<br />

Building 14A as close-up conditions cannot be met.<br />

3.2 Recommendation for Certification<br />

3.2.1 Exterior:<br />

3.2.2 Interior:<br />

Fourteen areas <strong>of</strong> contamination were identified and<br />

removed. Soil samples after excavation and prior to<br />

backfilling indicate that the limits <strong>of</strong> 5 pCi/g in the<br />

surface 15 cm. and 15 pCi/g in any 15 cm. layer below the<br />

surface are not exceeded. Based on this information, we<br />

recommend that the exterior <strong>of</strong> this vicinity property be<br />

certified to be in compliance with EPA standards for the<br />

UNTRA Project.<br />

Remedial action was conducted in the structure. All gammu<br />

readings taken in the structure following remedial action<br />

were less than the 20 micro R/hr above background limit.<br />

Radon daughter concentrations are below the 0.01 WL limit<br />

for grab samples. Based on this information, we reconmend<br />

that the interior be certified to be within the limits <strong>of</strong><br />

the EPA standards for the UNTRA Project.<br />