02.06.2013 Views

MS 3501, MS 3504 MS 3501i, MS 3504i - ILPhotonics.com

MS 3501, MS 3504 MS 3501i, MS 3504i - ILPhotonics.com

MS 3501, MS 3504 MS 3501i, MS 3504i - ILPhotonics.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

0,35 m MONOCHROMATOR - SPECTROGRAPH<br />

Each Model is an F/3,8 instrument with a focal length of 350 mm.<br />

The optics in the Models <strong>MS</strong><strong>3501</strong>i and <strong>MS</strong><strong>3504</strong>i correct for the astigmatism to enable the use<br />

of the devices in multi-track spectroscopy as well as operation with low-light sources in<br />

Emission, Fluorescence and Raman Spectroscopy.<br />

Models <strong>MS</strong><strong>3501</strong>, <strong>MS</strong><strong>3501</strong>i use one easy-changeable or fixed grating,<br />

Models <strong>MS</strong><strong>3504</strong>, <strong>MS</strong><strong>3504</strong>i use a four-grating turret to provide automatic grating switching.<br />

FEATURES<br />

High throughput<br />

Complete <strong>com</strong>puter control<br />

Four-grating turret (for <strong>MS</strong><strong>3504</strong> and <strong>MS</strong><strong>3504</strong>i)<br />

with automatic grating switching<br />

Low stray light and no re-entrant spectra<br />

Continuously automatically or manually<br />

variable slits<br />

Two flat field output ports with automatic port<br />

switching allow simultaneous mounting<br />

of different detectors<br />

Original software Win’9x/ME/2000/XP<br />

APPLICATIONS<br />

UV to IR measurement<br />

Emission, Fluorescence and<br />

Raman Spectroscopy<br />

Absorption and Transmission<br />

Multi-track Spectroscopy (CCD and CID) -<br />

with Models <strong>MS</strong><strong>3501</strong>i and <strong>MS</strong><strong>3504</strong>i<br />

Monochromator-Spectrograph<br />

MODELS<br />

<strong>MS</strong> <strong>3501</strong>, <strong>MS</strong> <strong>3504</strong><br />

Imaging<br />

Monochromator-Spectrograph<br />

MODELS<br />

<strong>MS</strong> <strong>3501</strong>i, <strong>MS</strong> <strong>3504</strong>i<br />

Optic Layout<br />

Models <strong>MS</strong><strong>3501</strong> and <strong>MS</strong><strong>3501</strong>i - Single Grating<br />

Models <strong>MS</strong><strong>3504</strong> and <strong>MS</strong><strong>3504</strong>i - 4-Grating Turret


SYSTEM<br />

Design:<br />

0,35 m Monochromator-Spectrograph, <strong>MS</strong>350 Series<br />

Ports:<br />

Usable wavelength range:<br />

F/number (input):<br />

Focal length:<br />

Main mirrors:<br />

Stray light:<br />

Flat field:<br />

SPECIFICATIONS<br />

IMAGING (Models <strong>MS</strong><strong>3501</strong>i and <strong>MS</strong><strong>3504</strong>i)<br />

Horizontal magnification:<br />

Vertical magnification:<br />

Imaging spatial resolution (aberration limited):<br />

DRIVE<br />

Motor:<br />

Drive:<br />

Step size:<br />

Precision:<br />

Max. speed:<br />

GRATINGS<br />

Grating rotation:<br />

Grating size:<br />

WAVELENGTH (grating 1200 l/mm)*<br />

Reciprocal dispersion:<br />

Wavelength repeatability:<br />

Wavelength resolution:<br />

Wavelength accuracy:<br />

Wavelength step size (aver):<br />

SLITS<br />

Motor (micrometer) driven slit assembly:<br />

Step size:<br />

Parallelism:<br />

Accuracy:<br />

Reading accuracy (micrometer):<br />

SYSTEM CONTROL<br />

Central control by on board CPU<br />

External control by Hand Controller<br />

Programmed control by external <strong>com</strong>puter<br />

External interface RS-232<br />

OVERALL SIZE: 510x395x200 mm<br />

WEIGHT: 18,5 kg<br />

* Other gratings are available (see p.58-59)<br />

Asymmetrical Czerny-Turner configuration<br />

in line using turning mirrors, plus axial port<br />

1 input, 2 output<br />

180 nm to 60 µ m<br />

3,8<br />

350 mm<br />

Spherical<br />

-5<br />

2,5 x 10 (20 nm from 632,8 laser line)<br />

28x10 mm<br />

1,17<br />

1,09<br />

~20 µm<br />

High torque microstepper<br />

Worm<br />

1,29 arc seconds<br />

+/- 1 step<br />

10000 steps/s<br />

Optical center<br />

70x70x10 mm<br />

2,37 nm/mm<br />

+/- 0,03 nm<br />

0,06 nm<br />

+/- 0,125 nm<br />

0,01 nm<br />

Width variable from 0 to 2,0 mm<br />

Diaphragm-adjustable height from 0 to 10 mm<br />

0,5 µ m<br />

+/- 1 µ m<br />

+/- 10 µ m<br />

2 µ m


170<br />

28...36<br />

100<br />

Grating<br />

turret<br />

193<br />

78<br />

18<br />

18<br />

Focal plane<br />

Adapter<br />

mounting site<br />

O<br />

45<br />

145<br />

38,5<br />

O<br />

37’<br />

Axial port<br />

Lateral port<br />

18...27,5 3,5<br />

Exit slit site<br />

0,35 m Monochromator-Spectrograph, <strong>MS</strong>350 Series<br />

Entrance<br />

slit<br />

53<br />

DIMENSIONAL DRAWING<br />

510<br />

O<br />

14 51<br />

53<br />

47<br />

54<br />

Focal plane<br />

EXIT SLIT ADAPTER<br />

+0,039<br />

40<br />

61<br />

M4 (4 places)<br />

295,7<br />

Integrated shutter<br />

68<br />

61<br />

M3 (4 places)<br />

Legs<br />

20<br />

Automated<br />

turning mirror<br />

16...24<br />

Focal plane<br />

18<br />

Mirrors<br />

RS-232<br />

18<br />

Detector flange<br />

mounting site<br />

29 max<br />

Blade surface of entrance slit<br />

288<br />

2,5<br />

DETECTOR ADAPTER<br />

+0,039<br />

45<br />

+0,039<br />

40<br />

53<br />

M3 (4 places)


RS232<br />

Detector<br />

0,35 m Monochromator-Spectrograph, <strong>MS</strong>350 Series<br />

Computer<br />

Adapter for<br />

Detector<br />

Combined Exit Slit<br />

Hand Controller<br />

AXIAL<br />

OUTPUT<br />

PORT<br />

Adapter for<br />

Exit Slit<br />

ACCESSORIES<br />

Manual<br />

Exit Slit<br />

Housing<br />

LATERAL<br />

INPUT<br />

PORT<br />

Fast Shutter<br />

Adapter for<br />

Detector<br />

LATERAL<br />

OUTPUT<br />

PORT<br />

Detector<br />

Combined<br />

Entrance Slit<br />

Manual<br />

Entrance Slit Fiber Filter<br />

Diaphragm<br />

Adapter Wheel<br />

Fiber Adapter<br />

Filter Wheel<br />

Adapter for<br />

Exit Slit<br />

Manual Exit Slit<br />

Fiber<br />

Adapter<br />

Fiber<br />

Adapter<br />

Combined<br />

Exit Slit

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!