Single A<br />
(50Hz/R410A/Heat Pump)<br />
5CSL0-06B(Re<strong>pl</strong>aces: 5CSL0-06A)
Introduction<br />
Part 1 General information<br />
1. Model line up.....................................................................................10<br />
1.1 Indoor units ............................................................................................................10<br />
1.2 Outdoor units..........................................................................................................11<br />
2. Nomenclature....................................................................................14<br />
2.1 Indoor units(Global) ...............................................................................................14<br />
2.2 Outdoor units(Global).............................................................................................14<br />
2.3 Indoor units(Europe) ..............................................................................................15<br />
2.4 Outdoor units(Europe) ...........................................................................................15<br />
2.5 Decoration panel....................................................................................................15<br />
3. List <strong>of</strong> functions................................................................................16<br />
4. Features.............................................................................................17<br />
4.1 What's system.........................................................................................17<br />
4.2 Technologies ..........................................................................................................18<br />
4.3 Indoor units ............................................................................................................20<br />
4.4 Outdoor units .........................................................................................................33<br />
5. Control system..................................................................................36<br />
5.1 Individual control system(Accessory).....................................................................36<br />
5.2 Central control system(Accessory) ........................................................................52<br />
5.3 Control device(Accessory) .....................................................................................53<br />
6. Combination......................................................................................54<br />
6.1 Selection procedure ...............................................................................................54<br />
6.2 Combination <strong>of</strong> indoor unit and outdoor unit ..........................................................54<br />
6.3 Synchro operation Guide .......................................................................................57<br />
2 General information
Part 2 Product data<br />
1. Indoor units.......................................................................................60<br />
1.1 Ceiling cassette 4-way ...................................................................................60<br />
1.2 Ceiling & floor.................................................................................................82<br />
1.3 Ceiling suspended..........................................................................................94<br />
1.4 Ceiling concealed duct - High static pressure ..............................................105<br />
1.5 Console(Floor stand)....................................................................................125<br />
2. Outdoor unit....................................................................................133<br />
2.1 DC Inverter SingleA (1, 3 phase) ................................................................133<br />
2.2 DC Inverter Single A-Synchro (1, 3 phase)..................................................216<br />
2.3 Non inverter Single A (1, 3 phase) ...............................................................245<br />
General information 3
Part 3 Design and installation<br />
1. General installation guideline........................................................288<br />
1.1 Installation process & Guideline ...................................................................288<br />
1.2 Checking the drawing ...................................................................................289<br />
2. Guideline for each installation process........................................290<br />
2.1 Sleeve and inserting work.............................................................................290<br />
2.2 Refrigerant piping work .................................................................................292<br />
2.3 Drain piping work .........................................................................................298<br />
2.4 Insulation work ..............................................................................................304<br />
2.5 Electrical work...............................................................................................307<br />
2.6 Air tight test ...................................................................................................310<br />
2.7 Vacuum drying works....................................................................................312<br />
2.8 Additional charge <strong>of</strong> refrigerant.....................................................................316<br />
2.9 Trail test run operation ..................................................................................317<br />
3. Installation <strong>of</strong> indoor unit ..............................................................318<br />
3.1 Safety precautions ........................................................................................318<br />
3.2 Ceiling cassette 4-way ..................................................................................322<br />
3.3 Ceiling and floor, Ceiling suspended only .....................................................330<br />
3.4 Ceiling concealed duct - High static pressure...............................................341<br />
3.5 Console (Floor stand) ...................................................................................347<br />
4. Installation <strong>of</strong> outdoor Unit ...........................................................355<br />
4.1 Safety precautions ........................................................................................355<br />
4.2 Introduction ...................................................................................................359<br />
4.3 Foundation ....................................................................................................360<br />
4.4 Settlement <strong>of</strong> the outdoor unit.......................................................................362<br />
4.5 Selection <strong>of</strong> the best location ........................................................................362<br />
4.6 Clearance space ...........................................................................................364<br />
4.7 Outdoor unit piping........................................................................................367<br />
4.8 Outdoor unit installation requirments ............................................................368<br />
4.9 Outdoor unit cabin.........................................................................................372<br />
4 General information
Part 4 Accessories<br />
List <strong>of</strong> ap<strong>pl</strong>icable models<br />
1. Controller accessories...................................................................377<br />
1.1 Wireless remote controller ...................................................................................377<br />
1.2 Sim<strong>pl</strong>e remote controller ......................................................................................382<br />
1.3 Deluxe remote controller......................................................................................384<br />
1.4 Hotel use remote controller..................................................................................386<br />
1.5 Zone controller .....................................................................................................388<br />
1.6 Dry contact module ..............................................................................................391<br />
2. Mechanical accessories .......................................................................393<br />
2.1 Branch kit .............................................................................................................393<br />
2.2 Drain pump ..........................................................................................................395<br />
2.3 Air guide...............................................................................................................400<br />
2.4 Cassette cover .....................................................................................................401<br />
General information 5
Introduction 5CSL0-06B<br />
Introduction<br />
Preface<br />
New era brings the more sophisticated and advanced buildings which in turn demands for specialized and optimized direct<br />
expansion air conditioning systems. Also energy efficiency, environment friendly, low noise and low maintenance cost are<br />
the features which are essential for these systems.<br />
As a part <strong>of</strong> vertical integration LG makes all the key components in house, which gives an edge to LG to make better and<br />
latest technology products with best quality in optimized time.<br />
systems with are equipped with DC inverter technology and R410A refrigerant which is perfect solution to various<br />
installation locations.<br />
LG system consists <strong>of</strong> a single common outdoor unit for single indoor unit, such as ceiling cassette, ceiling and<br />
floor, ceiling suspended, ceiling concealed duct(H) and Console(Floor stand). Synchro operation is solution to customer<br />
with reasonable prices.<br />
It uses 2,3 or 4 indoor units with one outdoor unit.<br />
Each indoor units are running as one cycle with same mode(cooling or heating).<br />
It helps same air distribution all arround the middle or larger room(<strong>of</strong>fice or open <strong>pl</strong>aces) even in irregualr shaped spaces.<br />
The total capacity based on ODU for Synchro operation are the same as for the fixed combinations.<br />
This Engineering product data book incorporates information about the product itself, its installation and designing for<br />
system.<br />
The comprehensive study <strong>of</strong> this book will improve your knowledge about the system and its ap<strong>pl</strong>ication in details.<br />
LG Electronics Inc.<br />
Air Conditioning Company<br />
6 General information
5CSL0-06B<br />
Publication history<br />
Introduction<br />
Pub. No. Category Type Refrigerant Outdoor units Notes Published in<br />
5CSI0-03A<br />
5CSS0-04D<br />
5CSL0-01A<br />
5CSL0-02A<br />
Inverter Single<br />
Variable Single<br />
All models Added Europe model names Jul.2005<br />
All models<br />
Deletion :<br />
AUUW486C[UU48W UYC]<br />
AUUW606C[UU60W UYC]<br />
Change :<br />
AUUW4860[UU48W UYB]<br />
AUUW6060[UU60W UYB]<br />
New edition <strong>of</strong> EPDB<br />
- Engineering data addition<br />
- Design and installation<br />
guideline addition<br />
-Delete the models<br />
-Change the model names<br />
Feb.2006<br />
Oct.2007<br />
5CSL0-03A<br />
CAC<br />
Inverter Single<br />
Non-inverter<br />
R410A<br />
AUUW126C[UU12W UEC]<br />
AUUW186C[UU18W UEC]<br />
AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED]<br />
AUUW366D[UU36W UED]<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW368D[UU37W UED]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
AUUH126C[UU12 ULC]<br />
AUUH186C[UU18 UEC]<br />
AUUH246D[UU24 UED]<br />
AUUH306D[UU30 UED]<br />
AUUH368D[UU37 UED]<br />
AUUH488D[UU48 U3D]<br />
AUUH608D[UU60 U3D]<br />
- Added outdoor unit models.<br />
- Added indoor unit models :<br />
ATNH126ELFC[UT12 NEC]<br />
ATNH186ELFC[UT18 NEC]<br />
ATNH24GPLED[UT24NPD]<br />
ATNH30GPLED[UT30NPD]<br />
ATNH36GNLED[UT36NND]<br />
ATNH42GMLED[UT42NMD]<br />
ATNH48GMLED[UT48NMD]<br />
ATNH60GMLED[UT60 NMD]<br />
ABNH186HLAC[UB18 NHC]<br />
ABNH246HLAD[UB24 NHD]<br />
ABNH306GLAD[UB30 NGD]<br />
ABNH366GLAD[UB36 NGD]<br />
ABNH426RLAD[UB42 NRD]<br />
ABNH486RLAD[UB48 NRD]<br />
ABNH606RLAD[UB60 NRD]<br />
AVNH126ELAC[UV12 NEC]<br />
AVNH186BLAC[UV18 NBC]<br />
AVNH246BLAD[UV24 NBD]<br />
AVNH306BLAD[UV30 NBD]<br />
AVNH366KLAD[UV36 NKD]<br />
AVNH426LLAD[UV42 NLD]<br />
AVNH486LLAD[UV48 NLD]<br />
AVNH606LLAD[UV60 NLD]<br />
Jan.2008<br />
5CSL0-04A<br />
5CSL0-05A<br />
5CSL0-05B<br />
5CSL0-06A<br />
5CSL0-06B<br />
Inverter Single<br />
Inverter Single<br />
Non-inverter<br />
High efficiency<br />
Inverter<br />
Inverter Single A<br />
High Efficiency<br />
Single A<br />
Inverter Synchro<br />
Single A<br />
Inverter Single<br />
Non-inverter<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
AUUW096D[UU09W ULD]<br />
AUUW126D[UU12W ULD]<br />
AUUW186D[UU18W UED]<br />
AUUH126D[UU12 ULD]<br />
AUUH186D[UU18 UED]<br />
AUUW186DH[UU18WH UED]<br />
AUUW216DH[UU21WH U4D]<br />
AUUW246DH[UU24WH U4D]<br />
All Models<br />
-Added outdoor unit models.<br />
- Added outdoor unit models.<br />
- Added indoor unit models<br />
ATNH09GRLED[UT09 NRD]<br />
ATNH12GRLED[UT12 NRD]<br />
ATNH18GQLED[UT18 NQD]<br />
ABNH186HLAD[UB18 NHD]<br />
AVNH09GELAD[UV09 NED]<br />
AVNH12GELAD[UV12 NED]<br />
AVNH186BLAD[UV18 NBD]<br />
AQNH09GALA0[CQ09 NA0]<br />
AQNH12GALA0[CQ12 NA0]<br />
AQNH18GALA0[CQ18 NA0]<br />
ATNH18GPLED[UT18 NPD]<br />
ATNH21GNLED[UT21 NND]<br />
ATNH24GNLED[UT24 NND]<br />
- Delete the wrong notes about Synchro<br />
Combination<br />
- Add information about the Branch Kit<br />
- Correct the Capacity Table<br />
AUUW186D1[UU18W UED1] -Added outdoor unit model<br />
- - Change the model names<br />
Feb.2008<br />
Feb.2009<br />
Oct.2010<br />
Dec.2010<br />
Dec.2010<br />
General information 7
Introduction 5CSL0-06B<br />
Step by step Single A system selection process (reference)<br />
(1) Calculate or obtain the maximum heat load for the area(s) to be air conditioned<br />
(2)<br />
(3)<br />
(4)<br />
(5)<br />
Indoor unit specifications<br />
Outdoor unit specifications<br />
Capacity coefficient factor<br />
Air flow and temperature distributions<br />
Selection <strong>of</strong> BD unit and branch<br />
Selection <strong>of</strong> the control system<br />
CAUTION<br />
Control wiring method<br />
Description <strong>of</strong> devices<br />
Electrical wiring<br />
Electrical characteristics<br />
Field wiring<br />
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas<br />
or alkaline gas, are produced.<br />
2. If the outdoor unit is installed close to the sea shore, direct exposure to the sea breeze<br />
should be avoided and choose an outdoor unit with anti-corrosion treatment.<br />
8 General information
Part 1 General information<br />
1. Model line up.........................................................................................10<br />
1.1 Indoor units .................................................................................................................10<br />
1.2 Outdoor units...............................................................................................................11<br />
2. Nomenclature........................................................................................14<br />
2.1 Indoor units(Global).....................................................................................................14<br />
2.2 Outdoor units(Global)..................................................................................................14<br />
2.3 Indoor units(Europe) ...................................................................................................15<br />
2.4 Outdoor units(Europe).................................................................................................15<br />
2.5 Decoration panel.........................................................................................................15<br />
3. List <strong>of</strong> functions....................................................................................16<br />
4. Features.................................................................................................17<br />
4.1 What's system..............................................................................................17<br />
4.2 Technologies ...............................................................................................................18<br />
4.3 Indoor units .................................................................................................................20<br />
4.4 Outdoor units...............................................................................................................33<br />
5. Control system......................................................................................36<br />
5.1 Individual control system(Accessory)..........................................................................36<br />
5.2 Central control system(Accessory) .............................................................................52<br />
5.3 Control device(Accessory) ..........................................................................................53<br />
6. Combination..........................................................................................54<br />
6.1 Selection procedure ....................................................................................................54<br />
6.2 Combination <strong>of</strong> indoor unit and outdoor unit ...............................................................54<br />
6.3 Synchro operation Guide ............................................................................................57<br />
General information 9
Model line up<br />
1. Model line up<br />
1.1 Indoor units<br />
Category Type<br />
Ceiling<br />
cassette<br />
Ceiling<br />
concealed<br />
duct<br />
4way<br />
Ceiling & floor<br />
Ceiling suspended<br />
Console<br />
High<br />
static<br />
pressure<br />
* High Efficiency Indoor Units<br />
Chassis<br />
TR ATNH09GRLED<br />
[UT09 NRD]<br />
TQ<br />
TP<br />
TN<br />
TM<br />
BH<br />
BG<br />
BR<br />
VE<br />
VB<br />
VK<br />
VL<br />
QA<br />
5CSL0-06B<br />
2.5 3.5 5.0 6.0 7.1 8.0 10.0 12.5 14.0 15.0<br />
AVNH09GELAD<br />
[UV09 NED]<br />
AQNH09GALA0<br />
[CQ09 NA0]<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
AVNH12GELAD<br />
[UV12 NED]<br />
AQNH12GALA0<br />
[CQ12 NA0]<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
*ATNH18GPLED<br />
[UT18 NPD]<br />
ABNH186HLAD<br />
[UB18 NHD]<br />
UVNH186BLAD<br />
[UV18 NBD]<br />
AQNH18GALA0<br />
[CQ18 NA0]<br />
*ATNH21GNLED<br />
[UT21 NND]<br />
Model Name<br />
Capacity, kW<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
*ATNH24GNLED<br />
[UT24 NND]<br />
ABNH246HLAD<br />
[UB24 NHD]<br />
UVNH246BLAD<br />
[UV24 NBD]<br />
ATNH30GPLED<br />
[UT30 NPD]<br />
ABNH306GLAD<br />
[UB30 NGD]<br />
UVNH306BLAD<br />
[UV30 NBD]<br />
ATNH36GNLED<br />
[UT36 NND]<br />
ABNH366GLAD<br />
[UB36 NGD]<br />
UVNH366KLAD<br />
[UV36 NKD]<br />
ATNH42GMLED<br />
[UT42 NMD]<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
UVNH426LLAD<br />
[UV42 NLD]<br />
ATNH48GMLED<br />
[UT48 NMD]<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
UVNH486LLAD<br />
[UV48 NLD]<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
UVNH606LLAD<br />
[UV60 NLD]<br />
10 General information
5CSL0-06B Model line up<br />
1.2 Outdoor units<br />
DC Inverter (1Ø)<br />
DC Inverter<br />
AUUW096D<br />
[UU09W ULD]<br />
AUUW126D<br />
[UU12W ULD]<br />
AUUW186D<br />
[UU18W UED]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong><br />
connectable indoor units<br />
kW 2.5 3.5 5.0<br />
Power sup<strong>pl</strong>y 1Ø, 220 - 240V, 50Hz<br />
Chassis<br />
DC Inverter<br />
AUUW246D<br />
[UU24W UED]<br />
AUUW306D<br />
[UU30W UED]<br />
AUUW186D1<br />
[UU18W UED1]<br />
AUUW366D<br />
[UU36W UED]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong><br />
connectable indoor units<br />
kW 7.1 8.0 10.0<br />
Power sup<strong>pl</strong>y 1Ø, 220 - 240V, 50Hz<br />
Chassis<br />
DC Inverter<br />
Synchro<br />
AUUW426D<br />
[UU42W U3D]<br />
AUUW486D<br />
[UU48W U3D]<br />
AUUW606D<br />
[UU60W U3D]<br />
No. <strong>of</strong> connectable indoor units 1~4<br />
Total capacity index <strong>of</strong><br />
connectable indoor units<br />
kW 12.5 14.0 15.0<br />
Power sup<strong>pl</strong>y 1Ø, 220 - 240V, 50Hz<br />
Chassis<br />
General information 11
Model line up<br />
DC Inverter (3Ø)<br />
DC Inverter<br />
Synchro<br />
AUUW428D<br />
[UU43W U3D]<br />
AUUW488D<br />
[UU49W U3D]<br />
AUUW608D<br />
[UU61W U3D]<br />
No. <strong>of</strong> connectable indoor units 1~4<br />
Total capacity index <strong>of</strong><br />
connectable indoor units<br />
kW 12.5 14.0 15.0<br />
Power sup<strong>pl</strong>y 3Ø, 380 - 415V, 50Hz<br />
Chassis<br />
DC Inverter<br />
AUUW368D<br />
[UU37W UED]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong><br />
connectable indoor units<br />
kW 10.0<br />
Power sup<strong>pl</strong>y 3Ø, 380 - 415V, 50Hz<br />
Chassis<br />
5CSL0-06B<br />
12 General information
5CSL0-06B Model line up<br />
DC Inverter High Efficiency models(1Ø)<br />
Non Inverter (1Ø, 3Ø)<br />
Heat pump<br />
AUUH368D<br />
[UU37 UED]<br />
AUUH488D<br />
[UU48 U3D]<br />
AUUH608D<br />
[UU60 U3D]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong> connectable<br />
indoor units<br />
kW 10.0 14.0 15.0<br />
Power sup<strong>pl</strong>y 3Ø, 380 - 415V, 50Hz<br />
Chassis<br />
Heat pump<br />
AUUH126D<br />
[UU12 ULD]<br />
AUUH186D<br />
[UU18 UED]<br />
AUUH246D<br />
[UU24 UED]<br />
AUUH306D<br />
[UU30 UED]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong> connectable<br />
indoor units<br />
kW 3.5 5.0 7.1 8.0<br />
Power sup<strong>pl</strong>y 1Ø, 220 - 240V, 50Hz<br />
Chassis<br />
DC Inverter super<br />
AUUW186DH<br />
[UU18WH UED]<br />
AUUW216DH<br />
[UU21WH U4D]<br />
AUUW246DH<br />
[UU24WH U4D]<br />
No. <strong>of</strong> connectable indoor units 1<br />
Total capacity index <strong>of</strong> connectable<br />
indoor units<br />
kW 5.0 6.0 7.1<br />
Power sup<strong>pl</strong>y 1Ø, 220 - 240V, 50Hz<br />
Chassis<br />
General information 13
Nomenclature<br />
2. Nomenclature<br />
Model number nomenclature<br />
2.1 Indoor unit(Global)<br />
A T N H 2 4 G N L E D<br />
2.2 Outdoor units(Global)<br />
A U U W 2 4 6 D H<br />
Serial number<br />
Functions<br />
A : Basic B : Low ambient<br />
C : Plasma filter E : Elevation grille<br />
F : Plasma filter + Elevation grille<br />
function circuit<br />
R : BLDC Motor + Plasma filter<br />
H : Plasma filter + Low ambient<br />
L : Plasma M : Plasma + Elevation grille<br />
Look<br />
L : Basic<br />
5CSL0-06B<br />
Chassis name<br />
Electrical ratings<br />
6: 1Ø, 220V-240V, 50Hz 8: 3Ø, 380V-415V, 50Hz G: 1Ø, 220-240V, 50/60 Hz<br />
Nominal cooling capacity in kW<br />
Ex) 24 -> 7.1 kW, 48 -> 14.0 kW<br />
Model type<br />
C : Cooling only H : Heat pump<br />
Indicates that this is a indoor unit for R410A<br />
ATN : Ceiling cassette type indoor unit<br />
ABN : Ceiling concealed duct type indoor unit<br />
AVN : Convertible, Ceiling and Floor type indoor unit<br />
UVN : Ceiling and Floor, Ceiling Suspended type indoor unit<br />
AQN : Console type indoor unit<br />
High efficiency model<br />
Serial number<br />
Electric standard (Phase, Volts, Freq)<br />
6:1Ø,220V-240V,50Hz<br />
8:3Ø,380V-415V,50Hz<br />
Nominal cooling capacity in kW<br />
09 : 2.5 kW<br />
12 : 3.5 kW<br />
18 : 5.0 kW<br />
24 : 7.1 kW<br />
30 : 8.0 kW<br />
36 : 10.0 kW<br />
42 : 12.5 kW<br />
48 : 14.0 kW<br />
60 : 15.0 kW<br />
Model type<br />
W : Inverter heat pump<br />
H : Heat pump<br />
Indicates that this is a<br />
R410A outdoor unit<br />
14 General information
5CSL0-06B Nomenclature<br />
2.3 Indoor unit(Europe)<br />
U T 2 4<br />
2.4 Outdoor units(Europe)<br />
U U 2 4 W H U4 D<br />
2.5 Decoration panel(For ceiling cassette models)<br />
P T - U M C<br />
N N D<br />
Serial number<br />
Chassis name<br />
Indoor unit<br />
Cooling / Heating capacity (kBtu/h)<br />
Type<br />
T : Cassette, B : Duct, V : Convertible, Q : Console<br />
Model type<br />
U : Universal model<br />
Serial number<br />
Outdoor unit chassis name<br />
High efficiency model<br />
Model type<br />
W : Inverter<br />
No mark for non-inverter model<br />
Cooling / heating capacity (kBtu/h)<br />
Type<br />
U : Outdoor units<br />
Model type<br />
U : Universal model<br />
Functions<br />
A : Basic C : Plasma air purifier<br />
Indoor unit chassis<br />
D : D Chassis E : E Chassis F : F Chassis<br />
H : H Chassis M : P, N, M Chassis<br />
Model type<br />
C : Cooling only H : Heat pump U : Universal<br />
Decoration panel <strong>of</strong> ceiling cassette type indoor unit<br />
General information 15
List <strong>of</strong> functions 5CSL0-06B<br />
3. List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
Ceiling Cassette<br />
4-way<br />
Ceiling & Floor<br />
Ceiling<br />
Suspended<br />
Ceiling Concealed<br />
Duct (High static)<br />
Console<br />
4 1 1 2 2<br />
- Manual Manual - Manual<br />
Auto Auto Auto - Auto<br />
X X - - X<br />
O O O - O<br />
4 / 5 / 4 3 / 4 / 3 3 / 4 / 3 3 / 3 / 3 4 / 5 / 4<br />
X X X - X<br />
- O O - O<br />
O O O - O<br />
O - - - X<br />
X X - - X<br />
Accessory X - X X<br />
O O O O O<br />
O - - Accessory X<br />
- - - O -<br />
O - Accessory - -<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
X X - X X<br />
X - X X X<br />
O O O O O<br />
O O* (Accessory) O* (Accessory) O O<br />
O O O X O<br />
O O* (Accessory) O (Accessory) O O<br />
X O O X O<br />
O O O O O<br />
O O* (Accessory) O (Accessory) O O<br />
O O* (Accessory) O (Accessory) O O<br />
O Accessory * Accessory O X<br />
O X X X Accessory<br />
X X X X X<br />
X X X X X<br />
X X X X X<br />
X X X X X<br />
Accessory O O Accessory O<br />
X X X X X<br />
Accessory Accessory Accessory Accessory ** Accessory **<br />
O O O O O<br />
X X X X X<br />
Accessory Accessory Accessory Accessory Accessory<br />
X X X X X<br />
- - X Accessory X<br />
Accessory Accessory Accessory Accessory X<br />
Note:<br />
* : Some <strong>of</strong> functions are slightly different depending upon models, refer individual function table on "PART 2. indoor units<br />
** : For ceiling concealed duct models, auto-run function <strong>of</strong> dry contact is not ap<strong>pl</strong>icabe. [If RF remote control use, auto-run function <strong>of</strong> dry contact is ap<strong>pl</strong>icable.(Refer to accessory PDB)]<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
16 General information
5CSL0-06B<br />
4. Features<br />
4.1 Whatʼs<br />
• Various IDU combination<br />
Cassette, consealed duct, convertible, console<br />
• Wide capacity range<br />
Indoor range : 2.5~15.0 kW<br />
Outdoor range : 2.5~15.0 kW<br />
• Convenient control<br />
Wired remote control<br />
Central controller<br />
• Long and high elevation piping<br />
• Wide operation range<br />
Cooling : -10~43 °CDB<br />
Heating : -15~24 °CDB<br />
Features<br />
General information 17
Features 5CSL0-06B<br />
4.2 Technologies<br />
Inverter Technology<br />
With the advancement <strong>of</strong> inverter technology comes more silent, economical and powerful air conditioning<br />
systems.<br />
Step-up Inverter by the PFC & the Sine Wave Control Technology (PFC :Power Factor Correction)<br />
The LG air conditioner is manufactured using the PFC and the sine wave technology. By the PFC contorl, raising the operating<br />
voltage from the existing DC 280V to DC 380V can be done. Thereby, it makes the operation smooth in a high-frequency<br />
area. The sine wave control enables s<strong>of</strong>t operation in a low frequency area, thereby expanding the product's operating<br />
range. This also markedly improves the product's energy efficiency.<br />
• Sine wave Control in BLDC Compressor<br />
Loss Full range<br />
Rectangle wave<br />
• PFC Control in Power Input<br />
V<br />
DC280V<br />
I<br />
Partial switching<br />
Powerful BLDC Compressor<br />
Sine wave<br />
The LG inverter air conditioner comes with a BLDC compressor<br />
that uses a strong neodymium magnet. Its compressor<br />
thus has improved efficiency compared with AC inverter.<br />
Notably, during partial-load operation (30-45 Hz), the efficiency<br />
<strong>of</strong> the compressor motor <strong>of</strong> the LG inverter air conditioner<br />
increases, as opposed to the existing AC motors, and<br />
the subcooling effects <strong>of</strong> the bigger condensor will further<br />
increase the product's energy consumption efficiency.<br />
V<br />
DC 380V<br />
(Boost up)<br />
Full range Sine wave switching<br />
I<br />
110Hz<br />
90Hz<br />
BLDC Fan motor<br />
BLDC fan motor <strong>of</strong>fers additional energy saving in operating<br />
mode. Compared with AC motors, BLDC fan motor can cut<br />
energy by 35%at full velocity. AC motor is operating at full<br />
velocity only, but BLDC Motor can change velocity according<br />
to load. Energy efficiency levels at low velocities in particular<br />
have been improved by 65%.<br />
65%<br />
Energy<br />
Saving<br />
35%<br />
Portial Load Full Load<br />
18 General information<br />
Motor Input<br />
Rectangle<br />
wave<br />
Load<br />
Sine<br />
wave<br />
AC Fan Motor<br />
DC Fan Motor
5CSL0-06B<br />
Top Class COP<br />
• DC Inverter Compressor<br />
• BLDC Fan Motor<br />
COP<br />
Cooling<br />
3.33<br />
*Testing Combinations<br />
Capacity<br />
Indoor<br />
3.70<br />
Outdoor<br />
Heating<br />
3.64<br />
3.21 3.21<br />
2.5kW 3.5kW 5.0kW<br />
3.62<br />
2.5kW 3.5kW 5.0kW<br />
UT09 NRD UT12 NRD UT18 NQD<br />
UU09W ULD UU12W ULD UU18W UED<br />
Temp<br />
Temp<br />
Temperature(°C)<br />
Setting<br />
Temperature<br />
Features<br />
Comfortable with Fast Cooling & Heating<br />
Performance<br />
When the air conditioner is initially activated to either heat<br />
or cool, the compressor will operate at maximum speed to<br />
reach the desired temperature quickly.<br />
Once the desired temperature is achieved, unlike conventional<br />
air conditioners that turn the compressor on and <strong>of</strong>f,<br />
LG inverter units constantly adjust and vary the compressor<br />
speed to maintain the desired temperature with minimal<br />
fluctuation to ensure that your comfort is not compromised.<br />
Conventional<br />
Setting Temp.<br />
General information 19<br />
Power<br />
Inverter<br />
Room Temp.<br />
Room Temp.<br />
On On On<br />
Off Off Off<br />
Power<br />
<br />
Power<br />
Input(W) ON ON<br />
ON<br />
<br />
Time<br />
Setting Temp.<br />
Time<br />
OFF OFF OFF<br />
Inverter<br />
(RED)<br />
Conventional<br />
(BLUE)<br />
Inverter<br />
(RED)<br />
Conventional<br />
(BLUE)
Features 5CSL0-06B<br />
4.3 Indoor units<br />
Ceiling Cassette – 4 way<br />
■ Compact design and easy installation<br />
■ Low noise<br />
■ Hygienic and easy-to-clean filter<br />
■ 2-thermistor(unit body and remote controller)<br />
■ Jet cool<br />
■ Plasma air purifying system(Accessory)<br />
■ High head drain pump(700mm)<br />
■ High-ceiling corresponding operation<br />
■ LCD wired remote controller<br />
■ Wireless remote controller(Accessory)<br />
• New Wired Remote Controller<br />
The wired remote controller with a large wide LCD screen<br />
featuring large font letters and a 4-direction key control<br />
enables the user more convenient control <strong>of</strong> operational conditions<br />
<strong>of</strong> the indoor unit.<br />
• 4 Vane Independent Operation<br />
Vane angle control satisfies both users who like direct wind<br />
or indirect wind. And also it prevents cold air draft.<br />
- This function can be controled with new wired remote controller<br />
(PQRCUSA0)<br />
900*900<br />
600*600<br />
• Big Font to see even from a<br />
distance<br />
• Large wide LCD for easy<br />
check<br />
• Easy installation<br />
Direct air flow Indirect air flow<br />
20 General information
5CSL0-06B<br />
All vane operation Individual vane operation Individual vane angle control<br />
• Wide Jet Air Flow<br />
Improved wide and narrow vane will provide comfortable temperature distribution without air flow dead zone.<br />
New<br />
Old<br />
• Elevation Grille (Accessory :PTEGMO)<br />
Easy filter cleaning with elevation grille<br />
- Installed inside main body<br />
- Auto horizontal level<br />
- 4 points support<br />
- Memory for user ʼs level<br />
- Max.4.5m length<br />
567mm<br />
80mm Wider!!<br />
4way<br />
4.5m<br />
Conventional<br />
3.5m<br />
Features<br />
4-Point Support Structure Auto Horizontal Control Memory for userês level Auto bottom detection<br />
General information 21
Features 5CSL0-06B<br />
• Slim & Compact size<br />
The indoor unit with slim and compact size enables successful<br />
installation in confined spaces.<br />
• Convenient Installation<br />
Easy installation with corner detachable decoration panel.<br />
Hanger adjust<br />
7.1 kW<br />
292 mm<br />
204 mm<br />
Model<br />
UT09<br />
UT12<br />
UT18<br />
UT24, UT30<br />
UT36<br />
UT42, UT48<br />
UT60<br />
Drain leakage<br />
check<br />
Hanger adjust<br />
Size<br />
214 mm<br />
214 mm<br />
256 mm<br />
204 mm<br />
246 mm<br />
288mm<br />
• One touch type Panel<br />
It provides easy installation with a one-touch detachable<br />
panel.<br />
• Extra high ceiling mode<br />
A 4.2m maximum high ceiling mode is available with the<br />
support <strong>of</strong> the indoor unit fan position control algorithm<br />
design. This setting <strong>of</strong>fers a reduction <strong>of</strong> droughts.<br />
• Independent Automatic Vane Control<br />
One motor per vane is adopted to control each <strong>of</strong> four vane<br />
independently, freely controlling air current according to situations.<br />
5 : 70°<br />
1 : 20°<br />
0 : 30°<br />
2 : 40°<br />
3 : 50°<br />
4 : 60°<br />
• Two Thermistor Control<br />
There may be a significant difference between the temperature<br />
taken at the installed product and indoor temperature.<br />
Two thermistor control provides option to control temperature<br />
by referring any <strong>of</strong> the two temperatures. With the help<br />
<strong>of</strong> the slide switch at the back <strong>of</strong> the LCD wired remote<br />
controller, selection <strong>of</strong> the desired thermistor for controlling<br />
the unit can be done. One thermistor is in the Indoor unit<br />
&the other one is in the LCD wired remote.<br />
22 General information
5CSL0-06B<br />
• Long Distance, High Elevation Piping<br />
LG air conditioners (cassette and concealed duct<br />
models)can be installed for long distance (up to 75m)and<br />
high elevation ap<strong>pl</strong>ications (up to 30m).<br />
• Weekly Program<br />
The operator can set an On/Off reservation <strong>of</strong> the air conditioner<br />
for a period <strong>of</strong> one week.<br />
LCD Wired Remote Controller<br />
• 24-Hour ON/OFF Timer in 1 hour intervals<br />
• TEST RUN Mode<br />
• Self-Diagnosis function<br />
• 3-Step Fan Speed selection<br />
• Operation Indication<br />
• Room Temperature Dis<strong>pl</strong>ay<br />
• Only 20mm thickness<br />
• Swirl Swing<br />
Swirl swing distributes air evenly throughout the room to<br />
ensure a more comfortable conditioned environment by<br />
adjusting the movement <strong>of</strong> the louvers.<br />
LG New Cassette<br />
Company A<br />
Vertical Temp. Differences Horizontal Temp. Differences<br />
Lover<br />
Lover<br />
Product<br />
Existing type<br />
Product<br />
Ceiling<br />
Ceiling<br />
pollutions<br />
Ceiling<br />
Ceiling pollutions prevention type<br />
Features<br />
• Design to Reduce the Ceiling Stains<br />
The new outlet design can reduce ceiling contamination<br />
from air current flowing along the ceiling.<br />
General information 23
Features 5CSL0-06B<br />
• Group Control<br />
1) Operation Summary<br />
- Where several products are linked, one specific control<br />
device can control a specific number <strong>of</strong> products.<br />
2) Specific Operation<br />
- Connecting line is linked to each <strong>of</strong> the indoor equipments<br />
for communication.<br />
A specific control device is connected to each <strong>of</strong> them<br />
and this control device can control the same function.<br />
- Group control function is enabled by dip switches in the<br />
wired remote control.<br />
At this time, the main system will not respond in order to<br />
prevent data collision.<br />
- While executing group control command, use the random<br />
data(0-3minutes) in the main body <strong>of</strong> indoor equipment<br />
for limiting starting current.<br />
- Control device can control up to 16 indoor equipments.<br />
• Cassette Cover<br />
(Accessory : PTDCQ / PTDCM)<br />
Maintains the ceiling elegance.<br />
- Covers the side area <strong>of</strong> cassette.<br />
- Gives elegant looks.<br />
- Light weight.<br />
- Suitable when false ceiling is unavailable.<br />
• Auto Changeover<br />
With reverse cycle models, the air conditioner will switch<br />
automatically from cooling to heating modes depending on<br />
the set temperature.<br />
• Initial Setting Temp :18 °C:<br />
(Memory the final setting temp)<br />
• Control <strong>of</strong> setting temp.<br />
Wired Remoted Controller:18~30 °C<br />
Reset Button in indoor unit: finally memorized temp.<br />
Wireless Remoted Controller: 23~27<br />
InsideTemp<br />
24 General information<br />
Temp<br />
+2<br />
+1<br />
+0.5<br />
Setting<br />
Temp<br />
-0.5<br />
-1<br />
-2<br />
COMP ON <strong>of</strong>f ON <strong>of</strong>f <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f<br />
Indoor FAN Setting -Low Setting -Low Stop Setting Low stop Setting -Low stop Setting Low<br />
Cycle Cooling<br />
Heating<br />
Cooling
5CSL0-06B<br />
• World Best COP<br />
• DC Inverter Compressor<br />
• BLDC Fan Motor<br />
• Powerful BLDC Compressor<br />
The LG inverter air conditioner comes with a BLDC compressor that<br />
uses a strong neodymium magnet. Its compressor thus has improved<br />
efficiency compared with AC inverter. Notably, during partial-load operation<br />
(30-45 Hz), the efficiency <strong>of</strong> the compressor motor <strong>of</strong> the LG<br />
inverter air conditioner increases, as opposed to the existing AC<br />
motors, and the subcooling effects <strong>of</strong> the bigger condensor will further<br />
increase the product's energy consumption efficiency.<br />
• BLDC Fan motor<br />
BLDC fan motor <strong>of</strong>fers additional energy saving in operating mode.<br />
Compared with AC motors, BLDC fan motor can cut energy by 35%at<br />
full velocity. AC motor is operating at full velocity only, but BLDC Motor<br />
can change velocity according<br />
to load. Energy efficiency levels at low<br />
velocities in particular have been<br />
improved by 65%.<br />
Stator Rotor<br />
• Quick Cooling &Heating<br />
Inverter air conditioners can operate their compressors faster to give<br />
them more powerful performance. This results in being able to attain<br />
the desired temperature much faster in both heating and cooling<br />
modes than conventional air conditioners.<br />
Features<br />
• High efficiency Inverter Technology<br />
You may have heard the excitement about Inverter technology, LG Inverters are the pinnacle <strong>of</strong> energy efficiency due to the<br />
innovative operation. Rather than using a constant speed compressor, the LG Inverter system uses a variable speed compressor,<br />
which means the Cooling or Heating capacity <strong>of</strong> the Air Conditioning can be varied to suit Indoor conditions.<br />
This makes the LG Inverter Units more economical & efficient to operate, produce less noise than standard counterparts and<br />
contain most superior features on the market.<br />
*Testing Combinations<br />
Capacity 5.0kW 6.0kW 7.1kW<br />
INDOOR<br />
OUTDOOR<br />
UT18H<br />
UU18WH<br />
UT21H<br />
UU21WH<br />
General information 25<br />
UT24H<br />
UU24WH<br />
Motor Input<br />
Temp<br />
COP<br />
Cooling<br />
3.70<br />
65%<br />
Energy<br />
Saving<br />
AC Fan Motor<br />
DC Fan Motor<br />
35%<br />
Portial Load Full Load<br />
Load<br />
50%<br />
Time <strong>of</strong><br />
Conventional<br />
4.07<br />
Heating<br />
5.0kW 6.0kW 7.1kW<br />
Conventional<br />
4.22<br />
3.85 3.65<br />
INVERTER<br />
4.15<br />
Setting Temp.<br />
Time
Features 5CSL0-06B<br />
Ceiling & Floor<br />
■ Flexible installation (Ceiling & Floor)<br />
■ 4-way airflow direction control<br />
(Automatic vertical airflow & manual horizontal airflow)<br />
■ LCD wireless remote controller<br />
■ BLDC fan motor (UV09 NED, UV12 NED)<br />
Flexible installation<br />
It can be installed on the floor or ceiling according<br />
to your need.<br />
<br />
<br />
Vertical airflow & balanced temperature<br />
distribution<br />
The heat distribution graph shows an exam<strong>pl</strong>e <strong>of</strong><br />
even temperature distribution achieved by the autoswing<br />
airflow.<br />
Upward<br />
Downward<br />
Auto Changeover<br />
With reverse cycle models, the air conditioner will<br />
switch automatically from cooling to heating modes<br />
depending on the set temperature.<br />
- Initial Setting Temp: 18 °C:(Memory the final setting<br />
temp)<br />
- Control <strong>of</strong> setting temp.<br />
Wired Remoted Controller: 18~30°C<br />
Reset Button in indoor unit:finally memorized temp.<br />
Wireless Remoted Controller: 23~27°C<br />
InsideTemp<br />
26 General information<br />
Temp<br />
+2<br />
+1<br />
+0.5<br />
Setting<br />
Temp<br />
-0.5<br />
-1<br />
-2<br />
COMP ON <strong>of</strong>f ON <strong>of</strong>f <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f<br />
Indoor FAN Setting -Low Setting -Low Stop Setting Low stop Setting -Low stop Setting Low<br />
Cycle Cooling<br />
Heating<br />
Cooling
5CSL0-06B<br />
Upgraded Function<br />
• One Touch Filter & Filter Cleaning Alarm Function<br />
• Power Wind Mode<br />
• Wired Remote Controller (Option)<br />
- 2 thermister control<br />
- Weekly Program<br />
- Group control.etc<br />
UV09, UV12<br />
UV18~UV60<br />
(PVRCUSZ0)<br />
Features<br />
New Wired Remote Controller (Option)<br />
The wired remote controller with a large wide LCD<br />
screen featuring large font letters and a 4-direction<br />
key control enables the user more convenient control<br />
<strong>of</strong> operational conditions <strong>of</strong> the indoor unit.<br />
UV09, UV12<br />
(PQRCUSA0)<br />
• Big Font to see even from a<br />
distance<br />
• Large wide LCD for easy<br />
check<br />
• Easy installation<br />
• 2 thermister control<br />
General information 27
Features 5CSL0-06B<br />
Ceiling Suspended<br />
1350 x 650 x 220 (UV36) 1750 x 650 x 220 (UV42 / UV48 / UV60)<br />
Customize size and weight<br />
• Weight : 65kg, 35kg<br />
• Volume : 100%, 68%<br />
Natural CHAOS wind<br />
• It swings at an angle, thus minimizing the difference in indoor temperatures and allowing air in every corner <strong>of</strong> the<br />
room.<br />
Auto air flow direction (up&down)<br />
• The air flow direction can be adjusted as desired by using the remote controller.<br />
• This is effective when you want to cool yourself directly<br />
One-touch air filter & filter chage alarm function<br />
• Easily change air filter when it is dirty.<br />
28 General information
5CSL0-06B<br />
Ceiling Concealed Duct – High static pressure<br />
■ Compact design and easy installation<br />
■ Phase control motor<br />
■ 2-thermistor control (unit body and remote controller)<br />
■ LCD wired remote controller<br />
■ Wireless remote controller(Accessory)<br />
■ High head drain pump(Accessory)<br />
■ Zone controller(Accessory)<br />
• E.S.P : External Static Pressure<br />
Always air volume and sound kept as design regardless <strong>of</strong><br />
E.S.P change using this technology, you can.<br />
• Optimize Duct work Installation<br />
• Keep Capacity & Sound level as desired<br />
• Sim<strong>pl</strong>ify model numbers<br />
The Phase control motor Technology gives benefit <strong>of</strong> saving<br />
money to Installer. Desired Air flowrate is obtained by controlling<br />
the phase <strong>of</strong> motor while installing the product and<br />
this makes your duct work system flexible.<br />
Air flow rate<br />
at 2mmAq<br />
Air flow rate<br />
at 10mmAq<br />
External static pressure(mmAq)<br />
Features<br />
• Quiet Operation & Easy Service<br />
A lightweight <strong>pl</strong>astic blower and housing makes air conditioning<br />
operation quiet and backup servicing more convenient.<br />
The new fan housing can be easily dismantled for convenient<br />
servicing and maintenance. The fan motor can be<br />
removed without the need to remove the com<strong>pl</strong>ete fan direct<br />
assembly.<br />
Conventional<br />
LG Fan and Housing<br />
General information 29
Features 5CSL0-06B<br />
• Central Controller<br />
Operation Summary<br />
LG units come with advanced control options, take for<br />
instance the Central Controller. Designed for the commercial<br />
ap<strong>pl</strong>ication, where multi<strong>pl</strong>e Air Conditioning units have<br />
been installed.<br />
You can control or fault find up to 16~2048 Air Conditioning<br />
units (via 8 separate controllers) individually or all together.<br />
1 2 3 4<br />
5 6 7 8<br />
9 10 11 12<br />
13 14 15 16<br />
On Of f<br />
1 2 16<br />
Controller<br />
#1<br />
1 2 3 4<br />
5 6 7 8<br />
9 10 11 12<br />
13 14 15 16<br />
On Of f<br />
1 2 16<br />
Controller<br />
#2<br />
1 2 3 4<br />
5 6 7 8<br />
9 10 11 12<br />
13 14 15 16<br />
On Of f<br />
Controller<br />
#8<br />
• Zone Controller<br />
This feature can be used to control the operation <strong>of</strong> the Air<br />
Conditioning Unit where each zone (maximum <strong>of</strong> 4 zones)<br />
has a separate thermostat and damper motor, your Air<br />
Conditioning Specialist can advise you if you require a VAV<br />
(Variable Air Volume) Installation in your home / <strong>of</strong>fice, as<br />
well as providing a quotation for Installation (including the<br />
sup<strong>pl</strong>y <strong>of</strong> thermostats and damper motors).<br />
Zone<br />
Control<br />
sub PCB<br />
ABZCA<br />
ROOM1<br />
Thermostat<br />
Damper Motor<br />
Damper Motor<br />
ROOM3<br />
Thermostat<br />
ROOM2<br />
Thermostat<br />
Damper Motor<br />
Damper Motor<br />
ROOM4<br />
Thermostat<br />
• Weekly Program<br />
The operator can set an On/Off reservation <strong>of</strong> the air conditioner<br />
for a period <strong>of</strong> one week.<br />
LCD Wired Remote Controller<br />
• 24-Hour ON/OFF Timer in<br />
1 hour intervals<br />
• TEST RUN Mode<br />
• Self-Diagnosis function<br />
• 3-Step Fan Speed selection<br />
• Operation Indication<br />
• Room Temperature Dis<strong>pl</strong>ay<br />
• Only 20mm thick<br />
• High Head Drain Pump<br />
Auxiliary Drain Pump automatically drains water. A standard<br />
drain-head height <strong>of</strong> up to 700mm is possible, creating the<br />
ideal solution for perfect water drainage.<br />
Drain Pipe Slope (1/50~1/100)<br />
Flexible Drain Hose<br />
Fixture<br />
Drain pipe<br />
(Accessory:ABDPG)<br />
• Long Distance, High Elevation Piping<br />
Our LG Air Conditioners(Cassette and Concealed duct<br />
model) are possible to be installed a long distance(Max<br />
75m) that is included High Elevation(30m)<br />
30 General information
5CSL0-06B<br />
Console (Floor stand)<br />
• Comfort Air Flow<br />
Features<br />
Different air flow <strong>of</strong> cooling & heating<br />
For cooling, the vane is adjusted upwards to let the cold air travel up. As for heating, the vane sends the heated air downwards<br />
to balance room temperature specially for floor.<br />
Quick floor heating<br />
Console air conditioners can operate faster to provide more powerful performance.<br />
The result is to attain the desired temperature much faster in floor heating mode than conventional air conditioners.<br />
27°C<br />
15°C<br />
Vertical<br />
Horizontal<br />
Lead Time for<br />
Heating<br />
(13°C 21°C)<br />
Average temp.(°C) 22.0[-1.0] 22.0[-1.0] 19.4[-3.6] 23.6[+0.6] 24.1[1.1]<br />
Vertical temp.<br />
difference (°C)<br />
Company D Company M Electric Heater LG LG<br />
Floor Heating Mode<br />
12 minutes<br />
30 second<br />
1.4<br />
[21.8~23.2]<br />
9 minutes<br />
40 second<br />
1.3<br />
[22.7~24.0]<br />
50 minutes<br />
4.9<br />
[15.7~20.6]<br />
EZ vane tap control Quiet operation (22dB)<br />
The indoor unit has a quiet operational noise level in the sleep mode to <strong>of</strong>fer<br />
calmness and comfort.<br />
• Healthy Air (3 stage air filter system)<br />
9 minutes<br />
30 second<br />
1.3<br />
[21.5~22.8]<br />
8 minutes<br />
40 second<br />
0.3<br />
[22.2~22.5]<br />
(Test Condition : Target Temp 23 °C,<br />
Indoor Room : 13 °C~, Outdoor Room :<br />
7 °C)<br />
1st Advanced pre filter : The antibacterial pre-filter primarily reduces large dust, mould and quilt<br />
dust.<br />
2nd Allergy Filter : Filter consists <strong>of</strong> enzyme that breaks down allergen, apatite, and organic/inorganic<br />
binder that attaches the enzyme to the filter. When the air passes the filter, allergen clings to the filter<br />
and like tiny pairs <strong>of</strong> scissors the enzymes cut allergen's protein to deactivate the allergen.<br />
3rd Plazma Ion Generator : The sterilized ion generating system, Ion Generator,<br />
emits around 1.2 million ions, and catches hazardous substances floating in the air, therefore<br />
proactively looking for and catching germs.<br />
General information 31
Features 5CSL0-06B<br />
• LG Unique design<br />
Console has been designed with the latest technologies to ensure optimum comfort.<br />
• EZ Installation & SVC<br />
6Way Pipe Installation<br />
It <strong>of</strong>fers 6way pipe so that fit various installation <strong>pl</strong>aces.<br />
Sliding-Type PCB at control box<br />
It can be installed different levels <strong>of</strong> user access which can be selected.<br />
It <strong>of</strong>fers even air distribution using upper and lower air diffuser.<br />
It has light weight but robust design.<br />
• Ez-Remote Controller<br />
User Friendly & Modern Design and<br />
Easy use!!<br />
- Comfortable to grab<br />
- Sliding type<br />
- Bigger size button<br />
- Highlighted some buttons with different<br />
colors<br />
- Easy to recognize functions with graphics<br />
• Full front panel<br />
• 3 dimensional round design<br />
32 General information
5CSL0-06B<br />
4.4 Outdoor units<br />
DC Inverter<br />
■ Inverter system<br />
- High efficiency<br />
- Low noise<br />
■ Meet EU New harmonics regulation<br />
■ New Design (12.5kW~)<br />
■ Long pipe / high elevation piping<br />
■ DC inverter full line up<br />
■ Energy saving using DC inverter<br />
Model name(1Ø) Model name(3Ø)<br />
Features<br />
2.5/3.5 kW 5.0 kW 7.1/8.0 kW 10.0 kW 12.5/14.0/15.0 kW<br />
AUUW096D[UU09W ULD], AUUW126D[UU12W ULD]<br />
AUUW186D[UU18W UED], AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED], AUUW366D[UU36W UED]<br />
AUUW426D[UU42W U3D], AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D], AUUW186D1[UU18W UED1]<br />
DC Inverter High efficiency<br />
Power sup<strong>pl</strong>y: 1Ø, 220-240V, 50Hz Power sup<strong>pl</strong>y: 3Ø, 380-415V, 50Hz<br />
■ Top class EER/COP<br />
■ New <strong>pl</strong>astic grille design, new ODU (6.0/7.1 kW)<br />
■ High efficiency technology<br />
■ Power operation and energy saving<br />
■ Low noise level<br />
5.0 kW 6.0/7.1 kW<br />
Model name(1Ø)<br />
AUUW186DH [UU18WH UED]<br />
AUUW216DH [UU21WH U4D]<br />
AUUW246DH [UU24WH U4D]<br />
Power sup<strong>pl</strong>y: 1Ø, 220-240V, 50Hz<br />
AUUW368D[UU37W UED]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
General information 33
Features 5CSL0-06B<br />
Non Inverter<br />
■ Reasonable solution<br />
■ Long pipe / high elevation piping up to 50m<br />
■ New Design (14.0/15.0 kW)<br />
■ Low noise level<br />
3.5 kW 5.0 kW 7.1/8.0 kW 10.0 kW 14.0/15.0 kW<br />
Model name(1Ø) Model name(3Ø)<br />
AUUH126D[UU12 ULD]<br />
AUUH186D[UU18 UED]<br />
AUUH246D[UU24 UED]<br />
AUUH306D[UU30 UED]<br />
AUUH368D[UU37 UED]<br />
AUUH488D[UU48 U3D]<br />
AUUH608D[UU60 U3D]<br />
Power sup<strong>pl</strong>y: 1Ø, 220-240V, 50Hz Power sup<strong>pl</strong>y: 3Ø, 380-415V, 50Hz<br />
34 General information
5CSL0-06B<br />
DC Inverter - Synchro (1Ø, 3Ø)<br />
Model name (1Ø)<br />
AUUW426D [UU42W U3D]<br />
AUUW486D [UU48W U3D]<br />
AUUW606D [UU60W U3D]<br />
Power sup<strong>pl</strong>y: 1Ø, 220-240V, 50Hz<br />
(Ex. Duo simultaneous operation)<br />
Circuit<br />
breaker<br />
(Ex. Trio simultaneous operation)<br />
Circuit<br />
breaker<br />
(Ex. Quartet simultaneous operation)<br />
Circuit<br />
breaker<br />
Features<br />
One large room can be cooled simultaneously by duo, trio or quartet<br />
indoor units according to the environmental needs.<br />
■ Synchro op<strong>pl</strong>ication<br />
■ Connectable to 2~4 indoor units by sim<strong>pl</strong>e branch kit piping<br />
■ DC inverter system<br />
- High efficiency<br />
- Low noise<br />
- High reliability<br />
■ Long pipe / high elevation piping<br />
■ New Design<br />
■ New Harmonics Regulation<br />
Model name (3Ø)<br />
AUUW428D [UU43W U3D]<br />
AUUW488D [UU49W U3D]<br />
AUUW608D [UU61W U3D]<br />
Power sup<strong>pl</strong>y: 3Ø, 380-415V, 50Hz<br />
Branch kit(PMUB11A)<br />
Branch kit(PMUB111A)<br />
Branch kit(PMUB1111A)<br />
Only one remote controller<br />
Only one circuit breaker.<br />
Only one remote controller<br />
Only one circuit breaker.<br />
Only one remote controller<br />
Only one circuit breaker.<br />
General information 35
Control system 5CSL0-06B<br />
5. Control system<br />
5.1 Individual control system(Accessory)<br />
Wired<br />
remote<br />
controller<br />
Item Model name Image<br />
Function<br />
Ap<strong>pl</strong>icable model<br />
5.1.1 Wide Remote controller (PQRCUSA0)<br />
Wired<br />
remote<br />
controller<br />
Standard PVRCUSZ0<br />
Sim<strong>pl</strong>e type PQRCUCA0<br />
Deluxe type PQRCUDS0<br />
For hotel use<br />
PQRCFCS0<br />
• On/<strong>of</strong>f, fan speed, mode, tempeture<br />
• Room tempeture<br />
• Fan, <strong>pl</strong>asma, swirl swing<br />
• Automatic<br />
• ESP function<br />
• Reservation(sim<strong>pl</strong>e/weekly)<br />
• Sim<strong>pl</strong>e reservation<br />
• Timer function<br />
• Auto swing, child lock<br />
• On/<strong>of</strong>f<br />
• Fan speed<br />
• Mode<br />
• Set temperature<br />
• Room temp<br />
• ESP function<br />
• Wireless remocon receiver<br />
• On/<strong>of</strong>f, fan speed, mode,<br />
tempeture<br />
• Room tempeture<br />
• Fan, <strong>pl</strong>asma, swirl swing<br />
• Automatic<br />
• Vane control<br />
• ESP function<br />
• Reservation(sim<strong>pl</strong>e/weekly)<br />
• Sim<strong>pl</strong>e reservation<br />
• Timer function<br />
• Auto swing, child lock<br />
• On/<strong>of</strong>f<br />
• Fan speed<br />
• Set temperature<br />
• Room tempeture<br />
• ESP function<br />
• Wireless remocon receiver<br />
For UV Synchro<br />
Ceiling cassette<br />
Ceiling & floor<br />
Ceiling concealed duct<br />
Item Model name Image<br />
Function<br />
Ap<strong>pl</strong>icable model<br />
Picto type PQRCUSA0<br />
❈ For detail information, refer to the accessory part <strong>of</strong> design & installation book.<br />
• On/<strong>of</strong>f, fan speed, mode,<br />
tempeture<br />
• Room tempeture<br />
• Fan, <strong>pl</strong>asma, swirl swing<br />
• Automatic<br />
• Vane control<br />
• ESP function<br />
• Reservation(sim<strong>pl</strong>e/weekly)<br />
• Sim<strong>pl</strong>e reservation<br />
• Timer function<br />
• Auto swing, child lock<br />
• 4 Vane independent operation<br />
Ceiling cassette<br />
36 General information
5CSL0-06B<br />
5.1.2 Wide Remote controller (PQRCUSA0) installation guide<br />
1) When installing more than 2 units <strong>of</strong> air<br />
conditioner to one wired remote controller,<br />
<strong>pl</strong>ease connect as the right figure.<br />
• If it is not event communication indoor unit, set the unit<br />
as slave.<br />
• Check for event communication through the product<br />
manual.<br />
• Refer to regarding <strong>page</strong> on how to set the slave.<br />
(Only Single IDU/ODU operation Not for Synchro<br />
Operation)<br />
2) When installing more than 2 wired remote<br />
controllers to one air conditioner, <strong>pl</strong>ease<br />
connect as the right picture.<br />
• When installing more than 2 units <strong>of</strong> wired remote controller<br />
to one air conditioner, set one wired remote controller<br />
as master and the others all as slaves, as shown<br />
in the right picture.<br />
• Refer to Installer setting section on how to set<br />
master/slave.<br />
• You cannot control the group as shown in the right for<br />
some products.<br />
(Only Single IDU/ODU operation Not for Synchro<br />
Operation)<br />
GND<br />
Signal wire<br />
12V<br />
Control system<br />
General information 37<br />
GND<br />
Signal wire<br />
GND<br />
Signal wire GND<br />
12V<br />
B Y R B Y R<br />
Signal wire<br />
12V<br />
MASTER SLAVE<br />
<br />
<br />
❊ Some products do not use 'Group control'. It depends on the product type.
Control system 5CSL0-06B<br />
Installer Setting -How to enter installer setting mode<br />
Installer setting mode is to set the detail function <strong>of</strong> the remote controller.<br />
If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage.<br />
This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated<br />
person should be responsible for the results. In this case, free service cannot be provided.<br />
1<br />
❈ Some contents may not be dis<strong>pl</strong>ayed depending on the product function.<br />
1<br />
2<br />
Press button for 4 secsonds to enter<br />
the installer setting mode. (When you<br />
enter the setting mode initially, Function<br />
code is dis<strong>pl</strong>ayed on the bottom <strong>of</strong> the<br />
LCD screen.)<br />
Function Code Value<br />
Repeat pressing button, the menu<br />
will change with the corresponding<br />
function code.<br />
Test Run → Address Setting → E.S.P.<br />
Value → Thermistor → Ceiling Height →<br />
Static Pressure → Group Setting →<br />
Override Setting → Dry Contact →<br />
Release 3Min. Delay → Zone State →<br />
Convert Temp. → Plasma → Electric<br />
heater → Humidifier → Elevation Grill →<br />
Ventilation Kit<br />
38 General information
5CSL0-06B<br />
<br />
No. Function Code Value<br />
1 Test Run 01 01:Set<br />
2 Address Setting 02 00~FF : Address<br />
<br />
01:VeryLow 0 ~ 255<br />
3 E.S.P. Value 03<br />
02:Low<br />
03:Med<br />
04:High<br />
05:Very High<br />
01:Remo<br />
4 Thermistor 04 02:Indoor<br />
03:2TH<br />
01:Med<br />
5 Ceiling Height 05<br />
02:Low<br />
03:High<br />
04:Very High<br />
01:V-H<br />
6 Static Pressure 06<br />
02:F-H<br />
03:V-L<br />
04:F-L<br />
7 Group Setting 07<br />
00:Slave<br />
01:Master<br />
8 Override Setting 08<br />
00:Slave<br />
01:Master<br />
9 Dry Contact 09<br />
00:OFF<br />
01:ON<br />
10<br />
Release 3 Min.<br />
Delay<br />
10 01:Set<br />
11 Zone State 11<br />
01:Variable<br />
02:Fixed<br />
12 Plasma 20<br />
13 Humidifier 22 00: Not Installed<br />
14 Elevation Grill 23 01: Installed<br />
15 Ventilation Kit 24<br />
❈ Some contents may not be dis<strong>pl</strong>ayed depending on the product function<br />
Function Code ESP step ESP value<br />
Control system<br />
General information 39
Control system 5CSL0-06B<br />
Installer Setting -Test Run Mode<br />
After installing the product, you must run a Test Run mode.<br />
For details related to this operation, refer to the product manual.<br />
1 2<br />
1<br />
2<br />
Keep pressing button setting for 4<br />
secs to enter installer setting mode until<br />
code dis<strong>pl</strong>ayed in timer segment.<br />
Function Code Set<br />
Press button to start.<br />
❈ 18˚C cooling, High Fan Speed, Airflow direction mode will be operated during 18 minutes with ignoring room temperature.<br />
❈ After running 18 minutes under test run mode, system will automatically turn OFF.<br />
❈ In case <strong>of</strong> duct type, the Airflow UP/DOWN function is not dis<strong>pl</strong>ayed.<br />
❈ During test run mode, receiving signal from wireless remote controller will release this operation.<br />
If you press any kind <strong>of</strong> button, Test Run mode will be released.<br />
40 General information
5CSL0-06B<br />
Installer Setting - Setting Address <strong>of</strong> Central Control<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
Press the button for 4<br />
seconds to enter the installer<br />
setting mode until timer segment<br />
dis<strong>pl</strong>ay "01:01".<br />
Repeat pressing button to select<br />
Function code 02.<br />
Function Code Group No<br />
Ex) Setting Address as 'F5'<br />
Set Group No. by pressing<br />
button.<br />
Indoor No.<br />
Move to Indoor No. setting option<br />
by pressing button.<br />
Set Indoor No. by pressing<br />
button.<br />
Press button to save or release.<br />
Press button to exit or system will<br />
automatically exit after 25 seconds<br />
without any input.<br />
Control system<br />
General information 41
Control system 5CSL0-06B<br />
Installer Setting -E.S.P.<br />
What is an E.S.P function?<br />
This is the function that decides the strength <strong>of</strong> the wind for each wind level and because this function is to make the<br />
installation easier, <strong>pl</strong>ease do not use this function when using the remote controller.<br />
If you set ESP incorrectly, the air conditioner may malfunction.<br />
This setting must be carried out by a certificated-technician.<br />
This function is used for only Duct product.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 03.<br />
Function Code ESP step ESP value<br />
Set ESP step by pressing button.<br />
(01: very low, 02: low, 03: medium, 04:<br />
high. 05: power)<br />
Move to ESP setting by pressing<br />
button.<br />
Press button to select ESP<br />
value(0~255).<br />
42 General information
5CSL0-06B<br />
6<br />
7<br />
❈ Weak and Power setting is not available for some products.<br />
Press button to save or release.<br />
Press button to exit or the system<br />
will automatically exit after 25 seconds<br />
without any input.<br />
Control system<br />
❈ Because the ESP value is already appropriately set when manufactured from the factory, it is recommended that<br />
you do not change the ESP value.<br />
General information 43
Control system 5CSL0-06B<br />
Installer Setting -Thermistor<br />
❈ Therefore system will use value that sensed from indoor unit or remote controller<br />
<br />
Temperature sensor location Function<br />
01 Remote controller Operation in indoor unit temperature sensor<br />
02 Indoor unit Operation in remote controller Temperature sensor<br />
03 2-Thermistor(2TH)<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 04.<br />
Function Code Thermistor setting<br />
Ex) Setting Thermistor as '2TH'.<br />
Set Thermistor mode by pressing<br />
button. (01: Remote Controller,<br />
02: Indoor, 03: 2TH)<br />
Press button to save or release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
Operation in lower temperature after comparing the temperature between the indoor unit<br />
and remote controller<br />
44 General information
5CSL0-06B<br />
Installer Setting -Ceiling Height Selection<br />
This function is to adjust FAN Airflow rate according to ceilingheight (only cassette model)<br />
<br />
Ceiling Height Level Description<br />
01 Low Decrease the indoor airflow rate 1 step from standard level<br />
02 Standard Set the indoor airflow rate as standard level<br />
03 High Increase indoor airflow rate 1 step from standard level<br />
04 Super high Increase indoor airflow rate 2 steps from standard level<br />
❈ Ceiling height setting is available only for some products.<br />
❈ Ceiling height <strong>of</strong> ʻSuper highʼ function may not exist depending on the indoor unit.<br />
❈ Refer to the product manual for more details.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 05.<br />
Function Code Ceiling height<br />
Ex) Setting Ceiling Height as 'Standard'.<br />
Select ceiling height value by pressing<br />
button.<br />
(01:Low, 02:Standard, 03:High,<br />
04:Super high)<br />
Press button to save or release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
Control system<br />
General information 45
Control system 5CSL0-06B<br />
Installer Setting -Static Pressure Setting<br />
This function is ap<strong>pl</strong>ied to only duct type. Setting this in other cases will cause malfunction.<br />
<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 06.<br />
Function Code Pressure<br />
Select static pressure by pressing<br />
button.<br />
(01:V-H, 02:F-H, 03:V-L, 04:F-L)<br />
Press button to save or<br />
release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
Pressure selection<br />
Zone state<br />
Function<br />
ESP standard value<br />
01 F-L Fixed Low<br />
02 F-H Fixed High<br />
03 V-L Variable Low<br />
04 V-H Variable High<br />
46 General information
5CSL0-06B<br />
Installer Setting-Group Setting<br />
This function is only for group control operation. Please donʼt set this function in case <strong>of</strong> non-group control.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay "01:01".<br />
Repeat pressing button to select<br />
Function code 07.<br />
Function Code Master/Slave value<br />
Ex) 'Master' Setting<br />
Select Master/ Slave by pressing<br />
button.<br />
(00: Slave, 01: Master)<br />
Press button to save or release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
Control system<br />
General information 47
Control system 5CSL0-06B<br />
Installer Setting -Mode Override Setting<br />
In case <strong>of</strong> More than 2 indoor units connected to 1 outdoor unit, they are assigned as Master indoor and Slave indoor.<br />
Therefore, they can operate together. (the setting code for this function is not dis<strong>pl</strong>ayed with un-equipped unit).<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay "01:01".<br />
Repeat pressing button to select<br />
Function code 08.<br />
Function Code Master/Slave<br />
Ex) Override 'Master' Setting<br />
Select Master/ Slave by pressing<br />
button.<br />
(00: Slave, 01 : Master)<br />
Press button to save or release<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
48 General information
5CSL0-06B<br />
Installer Setting-Dry Contact Mode Setting<br />
Control system<br />
This function allows the Dry contact-indoor unit operate under Auto Run mode or Manual mode with remote controller.<br />
* Please refer to dry contact manual for more details.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 09.<br />
Function Code Dry Contact setting value<br />
Ex) Setting Dry Contact Mode 'ON'<br />
Select Dry contact setting by<br />
pressing button.<br />
(00: OFF, 01: ON)<br />
Press button to save or release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
General information 49
Control system 5CSL0-06B<br />
Installer Setting-Zone State Setting<br />
This function is only available on some products.<br />
It is possible to setup Variable or Fixed option for Zone State <strong>of</strong> indoor. The initial setting is 'Variable'<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
Function code 11.<br />
Function Code Zone State fixing mode<br />
Ex) Setting Zone State as 'Fixed'.<br />
Select Zone State rate fixing mode by<br />
pressing button.<br />
(01: Variable, 02: Fixed)<br />
Press button to save or release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
50 General information
5CSL0-06B<br />
Installer Setting -Optional Function Setting<br />
Control system<br />
For the optional product such as PLASMA PURIFICATION/dehumidifier/ electric heater and ventilation, elevation grill.<br />
It is possible to set the items are installed or not<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Press button for 4 seconds<br />
to enter the installer setting<br />
mode until timer segment<br />
dis<strong>pl</strong>ay “01:01”.<br />
Repeat pressing button to select<br />
function code.<br />
(20: PLASMA PURIFICATION,<br />
21: DEHUMIDIFIER,<br />
22: ELECTRIC HEATER,<br />
23: ELEVATION GRILL,<br />
24: VENTILATION KIT)<br />
Function Code Existing condition<br />
Select existing condition<br />
<strong>of</strong> each mode by pressing<br />
button.<br />
(00: not installed,<br />
01 : installed)<br />
Press button to save or<br />
release.<br />
Press button to exit or<br />
system will automatically exit<br />
after 25 seconds without any<br />
input.<br />
General information 51
Control system 5CSL0-06B<br />
5.2 Central control system(Accessory)<br />
Central controller<br />
Item Model name Image Ap<strong>pl</strong>icable model<br />
Sim<strong>pl</strong>e central<br />
controller<br />
Sim<strong>pl</strong>e central<br />
controller<br />
(function controller<br />
available)<br />
Function controller<br />
Deluxe central<br />
controller<br />
(without schedule<br />
function)<br />
Deluxe central<br />
controller<br />
(with schedule<br />
function)<br />
PC based central<br />
controller<br />
(without schedule<br />
function)<br />
PC based central<br />
controller<br />
(with schedule<br />
function)<br />
PQCSA101S0<br />
PQCSB101S0<br />
PQCSC101S0<br />
PQCSW501A0<br />
PQCSW502A0<br />
PQCSS501A0<br />
PQCSS502A0<br />
❈ For detail information, refer to the network solution part <strong>of</strong> design & installation book.<br />
Ceiling cassette<br />
Ceiling & floor<br />
Ceiling concealed duct<br />
52 General information
5CSL0-06B<br />
5.3 Control device(Accessory)<br />
Control system<br />
Item Model name Image Ap<strong>pl</strong>ication model<br />
BMS_LW<br />
PDI<br />
(Power distributor indicator)<br />
Product<br />
interface units<br />
LonWorks<br />
for BMS<br />
PI485<br />
CNU<br />
Dry_contact<br />
PQNFB16A0<br />
PQNUD1S00<br />
PMNFP14A0<br />
PQNFG00A0<br />
PQDSA<br />
PQDSB<br />
❈ For detail information, refer to the network solution part <strong>of</strong> design & installation book.<br />
Ceiling cassette<br />
Ceiling & floor<br />
Ceiling concealed duct<br />
General information 53
Combination 5CSL0-06B<br />
6. Combination<br />
6.1 Outdoor units selection<br />
In general, outdoor unit may be selected as follows, though the location <strong>of</strong> the unit, and usage <strong>of</strong> the room, etc.<br />
should be considered.<br />
The combination <strong>of</strong> indoor and outdoor unit was to be decided that the sum <strong>of</strong> indoor unit capacity index should<br />
be smaller than the max. combination capacity <strong>of</strong> outdoor unit. Up to 2 ~ 4 indoor units can be connected to one<br />
outdoor unit. It is recommended to choose a large capacity outdoor unit if the installation space is large enough.<br />
6.2 Combination <strong>of</strong> indoor and outdoor unit<br />
Outdoor Units - 1Ø, 3Ø<br />
LGʼs system consist <strong>of</strong> one outdoor unit which can match with Four different indoor units as individual<br />
system.<br />
Category<br />
Standard Line up<br />
High efficiency Line up<br />
Outdoor unit Indoor unit<br />
1Ø 3Ø Type Model name<br />
Ceiling Cassette ATNH09GRLED[UT09 NRD]<br />
AUUW096D[UU09W ULD] - Ceiling & Floor AVNH09GELAD[UV09 NED]<br />
Console AQNH09GALA0[CQ09 NA0]<br />
Ceiling Cassette ATNH12GRLED[UT12 NRD]<br />
AUUW126D[UU12W ULD] - Ceiling & Floor AVNH12GELAD[UV12 NED]<br />
Console AQNH12GALA0[CQ12 NA0]<br />
Ceiling Cassette ATNH18GQLED[UT18 NQD]<br />
AUUW186D[UU18W UED] -<br />
Ceiling concealed duct<br />
Ceiling & Floor<br />
ABNH186HLAD[UB18 NHD]<br />
UVNH186BLAD[UV18 NBD]<br />
Console AQNH18GALA0[CQ18 NA0]<br />
Ceiling Cassette ATNH18GQLED[UT18 NQD]<br />
AUUW186D1[UU18W UED1] -<br />
Ceiling concealed duct<br />
Ceiling & Floor<br />
ABNH186HLAD[UB18 NHD]<br />
UVNH186BLAD[UV18 NBD]<br />
Console AQNH18GALA0[CQ18 NA0]<br />
Ceiling Cassette ATNH24GPLED[UT24 NPD]<br />
AUUW246D[UU24W UED] - Ceiling concealed duct ABNH246HLAD[UB24 NHD]<br />
Ceiling & Floor UVNH246BLAD[UV24 NBD]<br />
Ceiling Cassette ATNH30GPLED[UT30 NPD]<br />
AUUW306D[UU30W UED] - Ceiling concealed duct ABNH306GLAD[UB30 NGD]<br />
Ceiling & Floor UVNH306BLAD[UV30 NBD]<br />
Ceiling Cassette ATNH36GNLED[UT36 NND]<br />
AUUW366D[UU36W UED] AUUW368D[UU37W UED] Ceiling concealed duct ABNH366GLAD[UB36 NGD]<br />
Ceiling suspended UVNH366KLAD[UV36 NKD]<br />
Ceiling Cassette ATNH42GMLED[UT42 NMD]<br />
AUUW426D[UU42W U3D] AUUW428D[UU43W U3D] Ceiling concealed duct ABNH426RLAD[UB42 NRD]<br />
Ceiling suspended UVNH426LLAD[UV42 NLD]<br />
Ceiling Cassette ATNH48GMLED[UT48 NMD]<br />
AUUW486D[UU48W U3D] AUUW488D[UU49W U3D] Ceiling concealed duct ABNH486RLAD[UB48 NRD]<br />
Ceiling suspended UVNH486LLAD[UV48 NLD]<br />
Ceiling Cassette ATNH60GMLED[UT60 NMD]<br />
AUUW606D[UU60W U3D] AUUW608D[UU61W U3D] Ceiling concealed duct ABNH606RLAD[UB60 NRD]<br />
Ceiling suspended UVNH606LLAD[UV60 NLD]<br />
AUUW186DH [UU18WH UED] ATNH18GPLED [UT18 NPD]<br />
AUUW216DH [UU21WH U4D] - Ceiling Cassette ATNH21GNLED [UT21 NND]<br />
AUUW246DH [UU24WH U4D] ATNH24GNLED [UT24 NND]<br />
54 General information
5CSL0-06B<br />
Synchro Outdoor Unit – 1Ø, 3Ø<br />
(AUUW-D)[UU-W]<br />
Combination<br />
Synchro operation is solution to customer with reasonable prices.<br />
It uses 2, 3 or 4 indoor units with one outdoor unit.<br />
Each indoor units are running as one cycle with same mode(cooling or heating).<br />
It helps same air distribution all arround the middle or larger room(<strong>of</strong>fice or open <strong>pl</strong>aces) even in irregualr shaped<br />
spaces.<br />
The total capacity based on ODU for Synchro operation are the same as for the fixed combinations.<br />
Possible indoor units: indoor unit series<br />
IDU : INDOOR UNIT<br />
ODU : OUT DOOR INUT<br />
BD : BRANCH DISTRIBUTOR UNIT<br />
REMO : WIRED REMOTE CONTROLLER<br />
OUTDOOR<br />
UNITS<br />
AUUW426D[UU42W U3D]<br />
AUUW428D[UU43W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW608D[UU61W U3D]<br />
Ap<strong>pl</strong>ied Accessiries<br />
Capacity (kW)<br />
Cooling Heating<br />
12.5 14.0<br />
14.0 16.0<br />
15.0 17.0<br />
Wired remote<br />
controller*<br />
BD unit<br />
Sim<strong>pl</strong>e central<br />
controller**<br />
Function<br />
controller**<br />
Duo<br />
Cassette Duct Ceiling & Floor<br />
UT24 NPD *2<br />
UT24 NPD *2<br />
UT30 NPD *2<br />
ODU<br />
PMUB11A<br />
Possible combination <strong>of</strong> indoor units<br />
Synchro<br />
Quartet<br />
Note:<br />
* When install ceiling and floor type synchro combinations, You must use wired remote controller "PVRCUSZ0"<br />
* In case <strong>of</strong> cassette or duct type synchro combinations, You can use only one wired remote controller included<br />
in the indoor units.<br />
** When using synchro operation,<br />
- Do not use wireless remote controller.<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central controller and function controller "PQCSB101S0 & PQCSC101S0" only.<br />
General information 55<br />
Trio<br />
ODU<br />
BD<br />
BD BD<br />
IDU IDU IDU IDU IDU IDU IDU IDU IDU<br />
REMO REMO REMO<br />
UB24 NHD *2<br />
UB24 NHD *2<br />
UB30 NGD *2<br />
UV24 NBD *2<br />
UV24 NBD *2<br />
UV30 NBD *2<br />
Cassette Duct Ceiling & Floor Cassette Duct Ceiling & Floor<br />
UT18 NQD *3<br />
UT18 NQD *3<br />
UT18 NQD *3<br />
UB18 NHD *3<br />
UB18 NHD *3<br />
UB18 NHD *3<br />
PVRCUSZO PVRCUSZO<br />
PMUB111A PMUB1111A<br />
PQCSB101S0<br />
PQCSC101S0<br />
UV18 NBD *3<br />
UV18 NBD *3<br />
UV18 NBD *3<br />
UT12 NRD *4<br />
UT12 NRD *4<br />
UT12 NRD *4<br />
ODU<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-
Combination 5CSL0-06B<br />
Non inverter Outdoor Units - 1Ø, 3Ø<br />
[AUUH-D] [UU-D]<br />
• Table <strong>of</strong> combination<br />
LGʼs system consist <strong>of</strong> one outdoor unit which can match with three different indoor units as individual<br />
system.<br />
The indoor units are ceiling cassette, ceiling concealed duct and ceiling & floor, Ceiling suspended, Console<br />
types.<br />
Outdoor unit Indoor unit<br />
1Ø 3Ø Type Model name<br />
AUUH126D[UU12 ULD] -<br />
Ceiling Cassette<br />
Ceiling & Floor<br />
ATNH12GRLED[UT12 NRD]<br />
AVNH12GELAD[UV12 NED]<br />
Ceiling Cassette ATNH18GQLED[UT18 NQD]<br />
AUUH186D[UU18 UED] - Ceiling concealed duct ABNH186HLAD[UB18 NHD]<br />
Ceiling & Floor UVNH186BLAD[UV18 NBD]<br />
Ceiling Cassette ATNH24GPLED[UT24 NPD]<br />
AUUH246D[UU24 UED] - Ceiling concealed duct ABNH246HLAD[UB24 NHD]<br />
Ceiling & Floor UVNH246BLAD[UV24 NBD]<br />
Ceiling Cassette ATNH30GPLED[UT30 NPD]<br />
AUUH306D[UU30 UED] - Ceiling concealed duct ABNH306GLAD[UB30 NGD]<br />
Ceiling & Floor UVNH306BLAD[UV30 NBD]<br />
Ceiling Cassette ATNH36GNLED[UT36 NND]<br />
- AUUH368D[UU37 UED] Ceiling concealed duct ABNH366GLAD[UB36 NGD]<br />
Ceiling suspended UVNH366KLAD[UV36 NKD]<br />
Ceiling Cassette ATNH48GMLED[UT48 NMD]<br />
- AUUH488D[UU48 U3D] Ceiling concealed duct ABNH486RLAD[UB48 NRD]<br />
Ceiling suspended UVNH486LLAD[UV48 NLD]<br />
Ceiling Cassette ATNH60GMLED[UT60 NMD]<br />
- AUUH608D[UU60 U3D] Ceiling concealed duct ABNH606RLAD[UB60 NRD]<br />
Ceiling suspended UVNH606LLAD[UV60 NLD]<br />
56 General information
5CSL0-06B<br />
6.3 Synchro Operation Guide<br />
6.3.1 Piping length guide<br />
Install the branch pipe so that pipe length and difference between high and low will not exceed below SPEC.<br />
h1<br />
L2<br />
L3<br />
L4<br />
L5<br />
Remote<br />
Controller<br />
Main (L1)<br />
Branch<br />
6.3.2 Additional refrigerant charging guide<br />
Indoor Unit Refrigerant Additional charging (kg)<br />
Duo<br />
Trio<br />
Quartet<br />
Model<br />
AUUW42-606(8)D<br />
Refrigerant = (L1-a) x B + (L2 + L3) x A<br />
Refrigerant = (L1-a) x B + (L2 + L3 + L4) x A<br />
Refrigerant = (L1-a) x B + (L2 + L3 + L4 + L5) x A<br />
a<br />
B<br />
7.5 0.04<br />
6.3.3 Electric Wiring method<br />
h2<br />
Pipe Length<br />
Total(L1+L2+L3+L4+L5)<br />
Main Pipe(L1)<br />
Branch Pipe - L2+L3+L4+L5<br />
Each Branch(L2, L3, L4, L5)<br />
In out (h1)<br />
In-In (h2)<br />
L1+L2,L1+L3,L1+L4,L1+L5<br />
L2-L3,L4-L5<br />
S Terminals on the indoor unit 4 1(L) 2(N) 3<br />
CN-REMO<br />
S Terminals on the indoor unit 3<br />
S Terminals on the indoor unit 2<br />
M Terminals on the indoor unit 1<br />
(380V-415V, 3N~)<br />
(220V-240V~)<br />
1(L) 2(N) 3<br />
1(L) 2(N) 3<br />
1(L) 2(N) 3<br />
CN-REMO<br />
CN-REMO<br />
CN-REMO<br />
Terminals on the<br />
Outdoor unit R S T N L N<br />
1(L) 2(N) 3<br />
Remote<br />
Controller<br />
POWER INPUT<br />
POWER INPUT<br />
Pipe Dia.<br />
(mm)<br />
Combination<br />
[Unit : m]<br />
Spec.<br />
Max 80<br />
General information 57<br />
Ø 6.35<br />
Ø 9.52<br />
A<br />
0.03 kg/m<br />
0.04 kg/m<br />
Max 50<br />
Max 40<br />
Max 15<br />
Max 30<br />
Max 1<br />
Max 70<br />
Max 10<br />
Fig.1 Piping length<br />
Fig.2 electric wiring
Combination 5CSL0-06B<br />
6.3.4 Main PCB Appearance<br />
(1) [DIP SW2] for [SETTING No. OF IDU] OR [LONG<br />
PIPE].<br />
1 TO 3 PIN SWITCHES RECOGNIZE IDU NORMAL-<br />
LY BEING UP AND DOWN ONE BY ONE.<br />
(2) [SW01B] for [AUTO-ADDRESSING]<br />
(3) [LED01G/LED02G] for SIGNALS<br />
Table 1. signals<br />
RED LED<br />
ON<br />
ON/OFF<br />
ON/OFF<br />
SLOW<br />
ON/OFF<br />
GREEN LED<br />
ON/OFF<br />
ON<br />
ON/OFF<br />
ON/OFF<br />
* ON / OFF : CONTINUOUS ON AND OFF.<br />
SLOW ON / OFF : AT A PERIOD OF 1.5s<br />
6.3.5 Auto addressing guide<br />
MEANS<br />
UNDERGOING<br />
SUCCEEDED<br />
FAILED<br />
CKECKING<br />
Addressing work assigns address to each indoor unit.<br />
When firstly installing product <strong>of</strong> ro<strong>pl</strong>acing the indoor unit<br />
PCB.<br />
It needs Auto Addressing for Synchro operation<br />
❈ Work procedure<br />
1) DIP SW2 correctly.(Ⓐ)<br />
2) Turn on main power.<br />
3) Press the SW01B for about 3 seconds within 3minutes<br />
After main power on.(Ⓑ)<br />
4) After step 3), the LED01H(green LED) rapidly flickers.When<br />
Addressing work is done, green LED is <strong>of</strong>f,<br />
else LED stops flickering and lights continuously.<br />
5) If you fail to perform the Addressing work, repeat step<br />
2),3).<br />
58 General information<br />
DIP SW2<br />
ON<br />
A<br />
B<br />
LED01H<br />
1 2 3 4 5<br />
SW01B LED01G/02G<br />
Table2.a DIP SW2 Setting<br />
ON<br />
Fig.3 ODU PCB<br />
DIP SW2 Indoor Unit No.<br />
1 2 3 4 5<br />
0 0 0 0 0<br />
ON<br />
1 2 3 4 5<br />
1 0 0 0 0<br />
ON<br />
1 2 3 4 5<br />
1 1 0 0 0<br />
ON<br />
1 2 3 4 5<br />
1 1 1 0 0<br />
ON<br />
1 2 3 4 5<br />
0 0 0 1 0<br />
1(Single)<br />
2(Duo)<br />
3(Trio)<br />
4(Quartet)<br />
Long Pipe
Part 2 Product data<br />
1. Indoor units............................................................................................60<br />
1.1 Ceiling cassette 4-way ..........................................................................................60<br />
1.2 Ceiling & floor........................................................................................................82<br />
1.3 Ceiling suspended ................................................................................................94<br />
1.4 Ceiling concealed duct - High static pressure.....................................................105<br />
1.5 Console(Floor stand) ..........................................................................................125<br />
2. Outdoor unit.........................................................................................133<br />
2.1 DC Inverter Single A (1, 3 phase) ......................................................................133<br />
2.2 DC Inverter Single A-Synchro (1, 3 phase).........................................................216<br />
2.3 Non inverter Single A (1, 3 phase) ......................................................................245<br />
CST 4 - Way 59
List <strong>of</strong> Functions 5CSL0-06B<br />
1. Indoor units<br />
1.1 Ceiling cassette 4-way<br />
1.1.1 List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
ATNH09GRLED<br />
[UT09 NRD]<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
4 4 4<br />
- - -<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
4/5/4 4/5/4 4/5/4<br />
X X X<br />
- - -<br />
O O O<br />
O O O<br />
- - -<br />
PTPKM0 PTPKM0 PTPKM0<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PQRCUSA0<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQWRHSF0 PQWRHSF0 PQWRHSF0<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
60 CST 4 - Way
5CSL0-06B<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
ATNH18GPLED<br />
[UT18 NPD]<br />
ATNH21GNLED<br />
[UT21 NND]<br />
List <strong>of</strong> Functions<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
4 4 4<br />
- - -<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
4/5/4 4/5/4 4/5/4<br />
X X X<br />
- - -<br />
O O O<br />
O O O<br />
- - -<br />
PTPKM0 PTPKM0 PTPKM0<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PQRCUSA0<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQWRHSF0 PQWRHSF0 PQWRHSF0<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
CST 4 - Way 61
List <strong>of</strong> Functions 5CSL0-06B<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
ATNH24GNLED<br />
[UT24 NND]<br />
ATNH30GPLED<br />
[UT30 NPD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
ATNH36GNLED<br />
[UT36 NND]<br />
4 4 4<br />
- - -<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
4/5/4 4/5/4 4/5/4<br />
X X X<br />
- - -<br />
O O O<br />
O O O<br />
- - -<br />
PTPKM0 PTPKM0 PTPKM0<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PQRCUSA0<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQWRHSF0 PQWRHSF0 PQWRHSF0<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
62 CST 4 - Way
5CSL0-06B<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
ATNH42GMLED<br />
[UT42 NMD]<br />
ATNH48GMLED<br />
[UT48 NMD]<br />
List <strong>of</strong> Functions<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
4 4 4<br />
- - -<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
4/5/4 4/5/4 4/5/4<br />
X X X<br />
- - -<br />
O O O<br />
O O O<br />
- - -<br />
PTPKM0 PTPKM0 PTPKM0<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PQRCUSA0<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQWRHSF0 PQWRHSF0 PQWRHSF0<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
CST 4 - Way 63
Specifications 5CSL0-06B<br />
1.1.2 Specifications<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions Body mm<br />
(WxHxD) Decorative Panel mm<br />
Weight Body kg<br />
Air Filter<br />
Decorative Panel kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling Cassette - 4way<br />
Model<br />
Decoration panel<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 ATNH09GRLED<br />
[UT09 NRD]<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
PT-UQC PT-UQC PT-UQC<br />
1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.3 0.3 0.3<br />
BLDC BLDC BLDC<br />
Turbo Turbo Turbo<br />
40*1 40*1 40*1<br />
8.5 / 7.0 / 6.0 9.5 / 8.0 / 7.0 13 / 12 / 11<br />
- - -<br />
Direct Drive Direct Drive Direct Drive<br />
2R x 8C x 18FPI 2R x 8C x 18FPI 2R x 10C x 18FPI<br />
570*214*570 570*214*570 570*256*570<br />
700*30*700 700*30*700 700*30*700<br />
14 14 15<br />
3 3 3<br />
Long life filter Long life filter Long life filter<br />
36/33/30 38/35/32 41/39/36<br />
6.35 6.35 6.35<br />
9.52 9.52 12.7<br />
32 / 25 32 / 25 32 / 25<br />
1.4 1.7 2.4<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor Thermistor<br />
R410A R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Note :<br />
Conversion Formula<br />
1. Capacities are based on the following conditions:<br />
kcal/h = kW × 859.8<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
CFM = CMM × 35.3<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
64 CST 4 - Way
5CSL0-06B<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions Body mm<br />
(WxHxD) Decorative Panel mm<br />
Weight Body kg<br />
Air Filter<br />
Decorative Panel kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling Cassette - 4way<br />
Model<br />
Decoration panel<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 *ATNH18GPLED<br />
[UT18 NPD]<br />
*ATNH21GNLED<br />
[UT21 NND]<br />
Specifications<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
PT-UMC PT-UMC PT-UMC<br />
1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.60 0.60 0.60<br />
BLDC BLDC BLDC<br />
Turbo Fan Turbo Fan Turbo Fan<br />
124*1 124*1 60*1<br />
17 / 15 / 13 19 / 16 / 14 17 / 15 / 13<br />
- - -<br />
Direct Drive Direct Drive Direct Drive<br />
2R x 8C x 19 2R x 10C x 19 2R x 8C x 19<br />
840*204*840 840*246*840 840*204*840<br />
950*25*950 950*25*950 950*25*950<br />
21 23.5 21<br />
5 5 5<br />
Long life filter Long life filter Long life filter<br />
39 / 37 / 34 38 / 36 / 34 39 / 37 / 34<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
32 / 25 32 / 25 32 / 25<br />
2.1 2.7 2.1<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor Thermistor<br />
R410A R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Note :<br />
Conversion Formula<br />
1. Capacities are based on the following conditions:<br />
kcal/h = kW × 859.8<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
CFM = CMM × 35.3<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
4. "*" means high efficient indoor unit<br />
CST 4 - Way 65
Specifications 5CSL0-06B<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions Body mm<br />
(WxHxD) Decorative Panel mm<br />
Weight Body kg<br />
Air Filter<br />
Decorative Panel kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling Cassette - 4way<br />
Model<br />
Decoration panel<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 *ATNH24GNLED<br />
[UT24 NND]<br />
ATNH30GPLED<br />
[UT30 NPD]<br />
ATNH36GNLED<br />
[UT36 NND]<br />
PT-UMC PT-UMC PT-UMC<br />
1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.60 0.60 0.60<br />
BLDC BLDC BLDC<br />
Turbo Fan Turbo Fan Turbo Fan<br />
124*1 60*1 124*1<br />
21 / 18 / 16 19 / 17 / 15 24 / 22 / 19<br />
- - -<br />
Direct Drive Direct Drive Direct Drive<br />
2R x 10C x19 2R x 8C x19 2R x 10C x 19<br />
840*246*840 840*204*840 840*246*840<br />
950*25*950 950*25*950 950*25*950<br />
23 21 23.5<br />
5 5 5<br />
Long life filter Long life filter Long life filter<br />
40 / 38 / 36 43 / 40 / 37 43 / 40 / 37<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
32 / 25 32 / 25 32 / 25<br />
2.7 2.5 2.7<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor Thermistor<br />
R410A R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Note :<br />
Conversion Formula<br />
1. Capacities are based on the following conditions:<br />
kcal/h = kW × 859.8<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
CFM = CMM × 35.3<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
4. "*" means high efficient indoor unit<br />
66 CST 4 - Way
5CSL0-06B<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions Body mm<br />
(WxHxD) Decorative Panel mm<br />
Weight Body kg<br />
Air Filter<br />
Decorative Panel kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling Cassette - 4way<br />
Model<br />
Decoration panel<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 ATNH42GMLED<br />
[UT42 NMD]<br />
ATNH48GMLED<br />
[UT48 NMD]<br />
Specifications<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
PT-UMC PT-UMC PT-UMC<br />
1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.72 0.72 0.72<br />
BLDC BLDC BLDC<br />
Turbo Fan Turbo Fan Turbo Fan<br />
124*1 124*1 124*1<br />
30 / 28 / 26 34 / 32 / 30 34 / 32 / 30<br />
- - -<br />
Direct Drive Direct Drive Direct Drive<br />
2R x 12C x 21 2R x12C x 21 2R x 12C x 21<br />
840*288*840 840*288*840 840*288*840<br />
950*25*950 950*25*950 950*25*950<br />
26 26 26<br />
5 5 5<br />
Long life filter Long life filter Long life filter<br />
46 / 44 / 40 49 / 47 / 43 49 / 47 / 43<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
32 / 25 32 / 25 32 / 25<br />
3.6 4.4 5.5<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor Thermistor<br />
R410A R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Note :<br />
Conversion Formula<br />
1. Capacities are based on the following conditions:<br />
kcal/h = kW × 859.8<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
CFM = CMM × 35.3<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Without optional accessories(i.e. Plasma kit, elevation grille etc.) and with maximum airvolume (Cassette type is using PQRCUS0)<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
CST 4 - Way 67
Dimensions 5CSL0-06B<br />
1.1.3 Dimensions<br />
ATNH09GRLED[UT09 NRD]<br />
ATNH12GRLED[UT12 NRD]<br />
8<br />
Part Name Remark<br />
Decoration panel<br />
PT-UQC<br />
air suction grille<br />
150<br />
86<br />
Ø70<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Drain pipe connection<br />
517<br />
378.6<br />
4-R20<br />
172<br />
3<br />
Ø70<br />
Power sup<strong>pl</strong>y connection<br />
Fresh air connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
1<br />
570<br />
517<br />
523<br />
ATNH12GRLED[UT12 NRD]<br />
1 / 220-240 / 50<br />
ATNH09GRLED[UT09 NRD]<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
Model name<br />
378.6<br />
380(Air outlet hole)<br />
700<br />
6.35<br />
9.52<br />
32/25<br />
6.35<br />
9.52<br />
32/25<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
68 CST 4 - Way<br />
2<br />
461<br />
570<br />
5<br />
4<br />
380(Air outlet hole)<br />
473<br />
700<br />
55<br />
22.5<br />
214<br />
53<br />
84.5 59.5<br />
34.5<br />
142.5<br />
30 19<br />
570<br />
6<br />
CHASSIS CODE: TR<br />
2.5/3.5 kW
5CSL0-06B<br />
ATNH18GQLED[UT18 NQD]<br />
8<br />
150<br />
86<br />
Ø70<br />
Part Name Remark<br />
Decoration panel<br />
PT-UQC<br />
air suction grille<br />
517<br />
378.6<br />
4-R20<br />
172<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Drain pipe connection<br />
3<br />
1<br />
570<br />
517<br />
523<br />
Ø70<br />
Power sup<strong>pl</strong>y connection<br />
Fresh air connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
378.6<br />
380(Air outlet hole)<br />
700<br />
2<br />
ATNH18GQLED[UT18 NQD]<br />
1/ 220-240 / 50<br />
Model name<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
6.35<br />
12.7<br />
32/25<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
Dimensions<br />
CST 4 - Way 69<br />
461<br />
570<br />
5<br />
4<br />
380(Air outlet hole)<br />
473<br />
700<br />
55<br />
22.5<br />
256<br />
76 94<br />
95.5<br />
125 59.5<br />
30 19<br />
142.5<br />
570<br />
6<br />
CHASSIS CODE: TQ<br />
5.0 kW
Dimensions 5CSL0-06B<br />
*ATNH18GPLED[UT18 NPD]<br />
ATNH24GPLED[UT24 NPD]<br />
ATNH30GPLED[UT30 NPD]<br />
8<br />
Ø70<br />
61.5<br />
66<br />
618<br />
Part Name Remark<br />
Decoration panel<br />
PT-UMC<br />
air suction grille<br />
787<br />
4-R20<br />
292<br />
Air discharge grille<br />
Gas pipe connection<br />
1<br />
Liquid pipe connection<br />
Drain pipe connection<br />
684<br />
840<br />
671<br />
500(Air outlet hole)<br />
618<br />
950<br />
2<br />
Ø70<br />
Power sup<strong>pl</strong>y connection<br />
Fresh air connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ATNH30GPLED<br />
[UT30 NPD]<br />
1 / 200-240 / 50<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
*ATNH18GPLED<br />
[UT18 NPD]<br />
3<br />
70 CST 4 - Way<br />
Model name<br />
1 / 200-240 / 50<br />
1 / 200-240 / 50<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
787<br />
840<br />
500(Air outlet hole)<br />
734<br />
950<br />
54<br />
9.52<br />
15.88<br />
32 / 25<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
32 / 25<br />
9.52<br />
15.88<br />
32 / 25<br />
6<br />
4 5<br />
204<br />
40<br />
1. Unit should be installed in com<strong>pl</strong>ance with the installation manual in the<br />
product box.<br />
2. Unit shall be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. The unit is powered from the outdoor unit. So power cable should be<br />
connected with the outdoor unit.<br />
* High efficiency indoor uni.<br />
25<br />
99<br />
82<br />
60<br />
65<br />
60 80<br />
840<br />
108<br />
7<br />
TP<br />
6.0/7.0 kW
5CSL0-06B<br />
*ATNH21GNLED[UT21 NND]<br />
*ATNH24GNLED[UT24 NND]<br />
ATNH36GNLED[UT36 NND]<br />
8<br />
Ø70<br />
79.5<br />
65.5<br />
Part Name Remark<br />
Decoration panel<br />
PT-UMC<br />
air suction grille<br />
618<br />
787<br />
292 No.<br />
4-R20<br />
1<br />
2<br />
Air discharge grille<br />
Gas pipe connection<br />
3<br />
4<br />
1<br />
Liquid pipe connection<br />
Drain pipe connection<br />
5<br />
6<br />
Ø70<br />
Power sup<strong>pl</strong>y connection<br />
Fresh air connection<br />
7<br />
8<br />
500(Air outlet hole)<br />
618<br />
950<br />
2<br />
684<br />
840<br />
671<br />
ATNH36GNLED<br />
[UT36 NND]<br />
1 / 200-240 / 50<br />
ATNH24GNLED<br />
[UT24 NND]<br />
ATNH21GNLED<br />
[UT21 NND]<br />
Model name<br />
3<br />
Dimensions<br />
CST 4 - Way 71<br />
1 / 200-240 / 50<br />
1 / 200-240 / 50<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
787<br />
840<br />
500(Air outlet hole)<br />
734<br />
950<br />
54<br />
9.52<br />
15.88<br />
32 / 25<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
32 / 25<br />
9.52<br />
15.88<br />
32 / 25<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
6<br />
4 5<br />
25<br />
246<br />
60<br />
82<br />
99<br />
65 40<br />
1. Unit should be installed in com<strong>pl</strong>ance with the installation manual in the<br />
product box.<br />
2. Unit shall be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. The unit is powered from the outdoor unit. So power cable should be<br />
connected with the outdoor unit.<br />
* High efficiency indoor uni.<br />
80<br />
840<br />
108 60<br />
7<br />
6.0/7.1/10.0 kW
Dimensions 5CSL0-06B<br />
ATNH42GMLED[UT42 NMD]<br />
ATNH48GMLED[UT48 NMD]<br />
ATNH60GMLED[UT60 NMD]<br />
8<br />
Ø70<br />
109<br />
66<br />
Part Name Remark<br />
Decoration panel<br />
PT-UMC<br />
air suction grille<br />
787<br />
618<br />
4-R20<br />
292<br />
Air discharge grille<br />
Gas pipe connection<br />
1<br />
Liquid pipe connection<br />
Drain pipe connection<br />
840<br />
684<br />
500(Air outlet hole)<br />
618<br />
950<br />
2<br />
671<br />
Ø70<br />
Power sup<strong>pl</strong>y connection<br />
Fresh air connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
ATNH48GMLED<br />
UT48 NMD]<br />
ATNH42GMLED<br />
[UT42 NMD]<br />
Model name<br />
1 / 220-240 / 50<br />
1 / 220-240 / 50<br />
1 / 220-240 / 50<br />
78<br />
3<br />
9.52<br />
15.88<br />
32 / 25<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
32 / 25<br />
9.52<br />
15.88<br />
32 / 25<br />
72 CST 4 - Way<br />
REFER TO EACH<br />
787<br />
840<br />
500(Air outlet hole)<br />
734<br />
950<br />
54<br />
4 5<br />
6<br />
40<br />
25<br />
135<br />
183<br />
288<br />
70<br />
148<br />
110 60 80<br />
840<br />
7<br />
TM<br />
12.5/14.0/15.0 kW
5CSL0-06B<br />
1.1.4 Piping diagrams<br />
Heating<br />
Cooling<br />
Th2<br />
Heat exchanger<br />
Turbo fan<br />
Th1 : Thermistor for suction air temp.<br />
Th2 : Thermistor for liquid line temp.<br />
Th3 : Thermistor for gas line temp.<br />
■ Refrigerant pipe connection port diameters<br />
Piping diagrams<br />
CST 4 - Way 73<br />
Th3<br />
Th1<br />
Gas pipe connection port<br />
(flare connection)<br />
Liquid pipe connection port<br />
(flare connection)<br />
Model Gas Liquid<br />
ATNH09GRLED[UT09 NRD]<br />
ATNH12GRLED[UT12 NRD]<br />
Ø9.52 Ø6.35<br />
ATNH18GQLED[UT18 NQD] Ø12.7 Ø6.35<br />
ATNH18GPLED[UT18 NPD]<br />
ATNH21GNLED[UT21 NND]<br />
ATNH24GNLED[UT24 NND]<br />
ATNH24GPLED[UT24 NPD]<br />
ATNH30GPLED[UT30 NPD] Ø15.88 Ø9.52<br />
ATNH36GNLED[UT36 NND]<br />
ATNH42GMLED[UT42 NMD]<br />
ATNH48GMLED[UT48 NMD]<br />
ATNH60GMLED[UT60 NMD]<br />
[Unit:mm]
Wiring diagrams 5CSL0-06B<br />
1.1.5 Wiring diagrams<br />
1) Wiring diagrams<br />
CONNECTOR NUMBER LOCATION POINT FUNCTION<br />
2) PCB<br />
CN-POWER AC POWER SUPPLY AC POWER LINE INPUT FOR INDOOR CONTROLLER<br />
CN-MOTOR1 FAN MOTOR OUTPUT MOTOR OUTPUT OF BLDC<br />
CN-D/PUMP DRAIN PUMP OUTPUT AC OUTPUT FOR DRAIN PUMP<br />
CN-DISP DISPLAY DISPLAY OF INDOOR STATUS<br />
CN-VANE1 / VANE2 STEP MOTOR STEP MOTOR OUTPUT<br />
CN-FLOAT FLOAT SWITCH INPUT FLOAT SWITCH SENSING<br />
CN-PIPE/IN SUCTION PIPE SENSOR PIPE IN THERMISTOR<br />
CN-PIPE/OUT DISCHARGE PIPE SENSOR PIPE OUT THERMISTOR<br />
CN-ROOM ROOM SENSOR ROOM AIR THERMISTOR<br />
CN-REMO REMOTE CONTROLLER REMOTE CONTROL LINE<br />
CN-CC DRY CONTACT DRY CONTACT LINE<br />
CN_D/PUMP<br />
CN_POWER<br />
CN_MOTOR<br />
CN_FLOAT CN_DISPLAY<br />
CN_VANE2 CN_VANE1<br />
CN_OPTION<br />
CN_REMO<br />
CN_ROOM<br />
CN_PIPE/IN<br />
CN_PIPE/OUT<br />
74 CST 4 - Way<br />
SW01
5CSL0-06B<br />
Air flow and temperature distributions (reference data)<br />
1.1.6 Air flow and temperature distributions (reference data)<br />
Model : 2.5kW/3.5kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
Temperature [°C]<br />
0.5<br />
1.0<br />
1.5<br />
2.0<br />
Cooling Heating<br />
2.7m<br />
0m<br />
2.5m 1.5m 0m<br />
1.5m 2.5m<br />
24<br />
22<br />
20<br />
18<br />
2.0<br />
1.5<br />
1.0<br />
0.5<br />
2m<br />
1m<br />
2.7m<br />
0m<br />
2.5m 1.5m 0m<br />
1.5m 2.5m<br />
Model : 5.0kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
24<br />
0.5<br />
1.0<br />
1.5<br />
22<br />
2.0<br />
18<br />
20<br />
18<br />
2.0<br />
18<br />
20<br />
20<br />
1.5<br />
4m 3m 2m 1m 0m 1m 2m<br />
22<br />
1.0<br />
0.5<br />
22<br />
24<br />
24<br />
3m<br />
3m<br />
2m<br />
1m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
Temperature [°C]<br />
CST 4 - Way 75<br />
0.5<br />
2.0<br />
1.5<br />
1.0<br />
2.0<br />
1.5<br />
2.7m<br />
0m<br />
2.5m 1.5m 0m<br />
1.5m 2.5m<br />
24<br />
21<br />
27<br />
30<br />
33<br />
1.0<br />
0.5<br />
2m<br />
1m<br />
2.7m<br />
0m<br />
2.5m 1.5m 0m<br />
1.5m 2.5m<br />
Cooling Heating<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
21<br />
24<br />
0.5<br />
27<br />
1.0<br />
1.5<br />
2.0<br />
4m 3m 2m 1m 0m 1m 2m<br />
30<br />
33<br />
2.0<br />
33<br />
33<br />
1.5<br />
30<br />
30<br />
1.0<br />
0.5<br />
27<br />
27<br />
24<br />
24<br />
21<br />
3m<br />
21<br />
3m<br />
2m<br />
1m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m
Air flow and temperature distributions (reference data)<br />
Model : 6.0kW/7.1kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
24<br />
1.0<br />
4m 3m 2m 1m 0m 1m 2m<br />
Model : 8.0kW<br />
23<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
1.0<br />
Temperature [°C]<br />
Cooling Heating<br />
2.0<br />
2.0<br />
1.5 1.5<br />
1.5<br />
18<br />
20<br />
22<br />
18<br />
20<br />
22<br />
1.0<br />
23<br />
24<br />
3m<br />
3m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
33 33<br />
30 30<br />
4m 3m 2m 1m 0m 1m 2m<br />
Cooling Heating<br />
3.0<br />
2.5<br />
3.0<br />
2.5<br />
2.0<br />
2.0<br />
1.5<br />
1.0<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
23<br />
22<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
2.7m<br />
2m<br />
1m<br />
5CSL0-06B<br />
76 CST 4 - Way<br />
22<br />
24<br />
0.5<br />
1.0<br />
2.0 2.0<br />
18 18<br />
2.7m<br />
33 33<br />
20<br />
20<br />
2m<br />
22<br />
23<br />
3m<br />
3m<br />
0m<br />
4m 5m<br />
1m<br />
0m<br />
4m 5m<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
Temperature [°C]<br />
24<br />
22<br />
27<br />
3.5<br />
3.0<br />
2.5<br />
2.0<br />
1.0<br />
30 30<br />
27 27<br />
1.0<br />
0.5<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
27<br />
3.5<br />
3.0<br />
2.5<br />
2.0<br />
1.0<br />
24<br />
3m<br />
3m<br />
3m<br />
3m<br />
24<br />
22<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
22<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m 5m
5CSL0-06B Air flow and temperature distributions (reference data)<br />
Model : 10.0kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
Model : 12.5kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
2.0<br />
1.0<br />
Temperature [°C]<br />
3.0<br />
4.0<br />
Cooling Heating<br />
Cooling Heating<br />
4.0<br />
3.0<br />
2.0<br />
1.0<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
24<br />
1.0<br />
Temperature [°C]<br />
22<br />
1.5<br />
20<br />
3.0<br />
2.5<br />
3.0<br />
2.5<br />
2.0<br />
2.0<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
18<br />
18<br />
1.5<br />
20<br />
1.0<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
23<br />
22<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
22<br />
3m<br />
3m<br />
24<br />
2.7m<br />
2m<br />
1m<br />
18 18<br />
2.7m<br />
33 33<br />
20<br />
20<br />
2m<br />
22<br />
23<br />
3m<br />
3m<br />
0m<br />
4m 5m<br />
1m<br />
0m<br />
4m 5m<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
Temperature [°C]<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
CST 4 - Way 77<br />
24<br />
22<br />
24<br />
22<br />
3.5<br />
3.0<br />
2.5<br />
2.0<br />
1.0<br />
1.0<br />
4.0<br />
33 33<br />
30 30<br />
27 27<br />
4.0<br />
3.0 3.0<br />
2.0<br />
30 30<br />
27 27<br />
3.5<br />
3.0<br />
2.5<br />
2.0<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
2.0<br />
1.0<br />
1.0<br />
3m<br />
3m<br />
3m<br />
22<br />
3m<br />
24<br />
24<br />
22<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m
Air flow and temperature distributions (reference data)<br />
Model : 14.0kW/15.0kW<br />
Discharge angle: 40°<br />
Air velocity [m/s]<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
23.9<br />
22.4<br />
0.5<br />
1<br />
21.0<br />
1.5<br />
20.3<br />
23.9<br />
2.5<br />
2<br />
19.2<br />
18.2<br />
Cooling Heating<br />
2.5<br />
2<br />
18.2<br />
19.2<br />
1.5<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
20.3<br />
23.9<br />
1<br />
3m<br />
21.0<br />
3m<br />
0.5<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
22.4<br />
23.9<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
Discharge angle: 50°<br />
Air velocity [m/s]<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
Temperature [°C]<br />
5m 4m 3m 2m 1m 0m 1m 2m<br />
5CSL0-06B<br />
78 CST 4 - Way<br />
25.3<br />
28.6<br />
27.4<br />
0.5<br />
30.8<br />
1<br />
31.4<br />
2<br />
1.5<br />
0.5<br />
32.8<br />
2.5<br />
34.3<br />
2.5<br />
2<br />
1.5<br />
0.5<br />
34.3<br />
32.8<br />
1<br />
0.5<br />
3m<br />
31.4 30.8<br />
3m<br />
28.6<br />
27.4<br />
3.2m<br />
2m<br />
1m<br />
0m<br />
4m 5m<br />
3.2m<br />
2m<br />
25.3<br />
1m<br />
0m<br />
4m 5m
5CSL0-06B Sound levels<br />
1.1.7 Sound levels<br />
Overall<br />
1.5m<br />
Sound pressure level<br />
Sound Pressure Level (dB re 20uPa)<br />
Octave Band Sound Pressure Level (dB re 20 Pa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
s<br />
20<br />
NC-25<br />
Approximate<br />
Hearing<br />
NC-20<br />
Threshold<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Ceiling<br />
ATNH09GRLED [UT09 NRD]<br />
ATNH12GRLED [UT12 NRD]<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20uPa)<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Notes:<br />
- Sound measured at 1.5m below<br />
the center <strong>of</strong> the unit.<br />
- Data is valid at free field condition<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Octave Band Center Frequency (Hz)<br />
CST 4 - Way 79<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
ATNH30GPLED [UT30 NPD] *ATNH21GNLED [UT21 NND]<br />
* High Efficiency Indoor units<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
ATNH18GQLED [UT18 NQD] ATNH24GPLED [UT24 NPD]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20uPa)<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
Approximate<br />
Hearing<br />
NC-20<br />
Threshold<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
*ATNH18GPLED [UT18 NPD]<br />
*ATNH24GNLED [UT24 NND]<br />
ATNH36GNLED [UT36 NND]<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
20<br />
NC-25<br />
Approximate<br />
Hearing<br />
NC-20<br />
Threshold<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)
Sound levels<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
ATNH42GMLED [UT42 NMD] ATNH48GMLED[UT48 NMD]<br />
ATNH60GMLED[UT60 NMD]<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
20<br />
NC-25<br />
Approximate<br />
Hearing<br />
NC-20<br />
Threshold<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
5CSL0-06B<br />
80 CST 4 - Way<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
5CSL0-06B<br />
1.1.8 Controller<br />
■ Wired remote controller<br />
1. Operation indication screen<br />
2. Set temperature button<br />
3. Wireless remote controller Receiver<br />
• Some products don't receive the wireless signals.<br />
4. Ventilation button<br />
5. Operation mode selection button<br />
6. Subfunction button<br />
7. Function setting button<br />
1<br />
2<br />
3<br />
4 10<br />
5<br />
6<br />
7<br />
8<br />
Controller<br />
CST 4 - Way 81<br />
9<br />
11<br />
12<br />
13<br />
14<br />
15<br />
8. Exit button<br />
9. On/ Off button<br />
10. Room temperature button<br />
11. Fan speed button<br />
12. Air flow button<br />
13. Reservation/ Time setting button<br />
14. Setting/ Cancel button<br />
15. Up, Down, Left, Right button<br />
Note<br />
❈ Dis<strong>pl</strong>ay temperature can be different from actual room temperature if the remote controller is installed at the <strong>pl</strong>ace where<br />
sun-rays are falling directly or the <strong>pl</strong>ace nearby heat source.<br />
❈ The actual product can be different from above contents depending upon model type.
List <strong>of</strong> functions 5CSL0-06B<br />
1.2 Ceiling and floor<br />
1.2.1 List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Deluxe wired remote controller<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
AVNH09GELAD<br />
AVNH12GELAD<br />
UVNH186BLAD<br />
[UV09 NED]<br />
[UV12 NED]<br />
[UV18 NBD]<br />
1 1 1<br />
Manual Manual Manual<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
3 / 4 / 3 3 / 4 / 3 3 / 4 / 3<br />
X X X<br />
O O O<br />
O O O<br />
- - -<br />
X X X<br />
X X X<br />
O O O<br />
- - -<br />
- - -<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
- - -<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PVRCUSZ0<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PVRCUSZ0<br />
O O O<br />
O O O<br />
PQRCUSA0 PQRCUSA0 PVRCUSZ0<br />
PQRCUSA0 PQRCUSA0 PVRCUSZ0<br />
PQRCUSA0 PQRCUSA0 PVRCUSZ0<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
O O O<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
82 Ceiling & Floor
5CSL0-06B<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Deluxe wired remote controller<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
UVNH246BLAD<br />
[UV24 NBD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
UVNH306BLAD<br />
[UV30 NBD]<br />
1 1<br />
Manual Manual<br />
Auto Auto<br />
X X<br />
O O<br />
3 / 4 / 3 3 / 4 / 3<br />
X X<br />
O O<br />
O O<br />
- -<br />
X X<br />
X X<br />
O O<br />
- -<br />
- -<br />
- -<br />
PVRCUSZ0 PVRCUSZ0<br />
O O<br />
O O<br />
O O<br />
O O<br />
X X<br />
- -<br />
O O<br />
PVRCUSZ0 PVRCUSZ0<br />
O O<br />
PVRCUSZ0 PVRCUSZ0<br />
O O<br />
O O<br />
PVRCUSZ0 PVRCUSZ0<br />
PVRCUSZ0 PVRCUSZ0<br />
PVRCUSZ0 PVRCUSZ0<br />
X X<br />
X X<br />
X X<br />
X X<br />
O O<br />
X X<br />
PQDSB PQDSB<br />
O O<br />
X X<br />
PMNFP14A0 PMNFP14A0<br />
X X<br />
X X<br />
PQRSTA0 PQRSTA0<br />
List <strong>of</strong> functions<br />
Ceiling & Floor 83
Specifications 5CSL0-06B<br />
1.2.2 Specifications<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions (WxHxD) Body mm<br />
Weight Body kg<br />
Air Filter<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling & Floor<br />
Model<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 AVNH09GELAD<br />
[UV09 NED]<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
AVNH12GELAD<br />
[UV12 NED]<br />
UVNH186BLAD<br />
[UV18 NBD]<br />
1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
BLDC BLDC Induction<br />
Cross Flow Fan Cross Flow Fan Cross Flow Fan<br />
20.0*1 20.0*1 30.0*1<br />
7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.2 13.5 / 12 / 11<br />
- - 1.5/370<br />
Direct Drive Direct Drive Direct Drive<br />
2R x 12C x 20 2R x 12C x 20 2R x 12C x 18<br />
900*200*490 900*200*490 1,200*205*615<br />
13.7 13.7 30.0<br />
Long life filter Long life filter Long life filter<br />
40 / 36 / 31 40 / 36 / 31 43 / 40 / 37<br />
6.35 6.35 6.35<br />
9.52 9.52 12.7<br />
20/16 20/16 20/16<br />
0.93 1.3 1.54<br />
Thermistor<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
84 Ceiling & Floor
5CSL0-06B<br />
Indoor unit type Ceilling & Floor<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor<br />
Drive<br />
μF/Vac<br />
Coil Row x Column x FPI mm<br />
Dimensions (WxHxD) Body mm<br />
Weight<br />
Air Filter<br />
Body kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Connectable outdoor unit<br />
l/h<br />
Power and transmission interunit cable No.x mm2 Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Specifications<br />
Model UVNH246BLAD [UV24 NBD] UVNH306BLAD [UV30 NBD]<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
Induction Induction<br />
Cross Flow Fan Cross Flow Fan<br />
35*1 42.5*1<br />
15 / 13.5 / 12 18 / 16 / 14<br />
1.5/370 1.5/370<br />
Direct Drive Direct Drive<br />
2R x 12C x 20 2R x 12C x 20<br />
1,200*205*615 1,200*205*615<br />
30 30<br />
Long life filter Long life filter<br />
45 / 42 / 39 45 / 42 / 39<br />
9.52 9.52<br />
15.88 15.88<br />
20/16 20/16<br />
3.2 3.5<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Ceiling & Floor 85
Dimensions 5CSL0-06B<br />
1.2.3 Dimensions<br />
AVNH09GELAD[UV09 NED]<br />
AVNH12GELAD[UV12 NED]<br />
1<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
86 Ceiling & Floor<br />
AVNH12GELAD[UV12 NED]<br />
1 / 220-240 / 50<br />
AVNH09GELAD[UV09 NED]<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
6.35<br />
9.52<br />
20 / 16<br />
6.35<br />
9.52<br />
20 / 16<br />
2.5/3.2 kW
5CSL0-06B<br />
UVNH186BLAD[UV18 NBD]<br />
UVNH246BLAD[UV24 NBD]<br />
UVNH306BLAD[UV30 NBD]<br />
1<br />
UVNH306BLAD<br />
[UV30 NBD]<br />
1 / 220-240 / 50<br />
UVNH246BLAD<br />
[UV24 NBD]<br />
UVNH186BLAD<br />
[UV18 NBD]<br />
Model name<br />
Dimensions<br />
Ceiling & Floor 87<br />
1 / 220-240 / 50<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
20/16<br />
9.52<br />
15.88<br />
20/16<br />
6.35<br />
12.7<br />
20/16<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
5<br />
5.0/7.1/8.0 kW
Piping diagrams 5CSL0-06B<br />
1.2.4 Piping diagrams<br />
Heating<br />
Cooling<br />
Th2<br />
Heat exchanger<br />
C.F.F<br />
Th1 : Thermistor for suction air temp.<br />
Th2 : Thermistor for liquid line temp.<br />
Th3 : Thermistor for gas line temp.<br />
Th3<br />
[Unit:mm]<br />
88 Ceiling & Floor<br />
Th1<br />
Gas pipe connection port<br />
(flare connection)<br />
Liquid pipe connection port<br />
(flare connection)<br />
Model Gas Liquid<br />
AVNH09GELAD[UV09 NED]<br />
AVNH12GELAD[UV12 NED]<br />
Ø9.52 Ø6.35<br />
UVNH186BLAD[UV18 NBD] Ø12.7 Ø6.35<br />
UVNH246BLAD[UV24 NBD]<br />
UVNH306BLAD[UV30 NBD]<br />
Ø15.88 Ø9.52
5CSL0-06B<br />
1.2.5 Wiring diagrams<br />
1) Wiring diagrams<br />
Models : AVNH09GELAD[UV09 NED], AVNH12GELAD[UV12 NED]<br />
Wiring diagrams<br />
Models : UVNH186BLAD[UV18 NBD], UVNH246BLAD [UV24 NBD], UVNH306BLAD [UV30 NBD]<br />
Connector Number Location Connector Number Location<br />
CN-POWER AC power sup<strong>pl</strong>y CN-TH2 Discharge pipe sensor<br />
CN-MOTOR BLDC fan motor output CN-TH1 Pipe and room sensor<br />
CN-DPUMP Drain pump output CN-HVB Air cleaner<br />
CN-AC/DC AC/DC connector CN-DOOR Step motor<br />
CN-DISPLAY Dis<strong>pl</strong>ay CN-UD1 Step motor<br />
CN-FLOAT Float switch input CN-CC Central control<br />
Ceiling & Floor 89
Wiring diagrams<br />
2) PCB<br />
CN_ CENTRAL<br />
CONTROL<br />
CN_ WRITE<br />
CN_ DISPLAY<br />
CN_ OPTION<br />
CN-POWER<br />
CN_ REMO<br />
CN_ PIPE/OUT<br />
SW01<br />
CN_ PIPE/IN CN_ ROOM<br />
CN_ vain 1<br />
1<br />
CN_ vain 2<br />
2<br />
CN_ DOOR CN_ MOTOR1<br />
CN_ MOTOR2<br />
<br />
CN_ POWER<br />
CN-MOTOR CN-DISP CN-REMO<br />
CN-FLOAT<br />
CN-PIPE1<br />
CN-ROOM<br />
5CSL0-06B<br />
CVT 1:Communication 2:Cycle 3:Group control 4:Dry Contact 5:Install 6:Heater link 7:Ventilator link 8:Extra<br />
Off (Factory Set) On H/P Master Manual Ceiling Off Off -<br />
On Off C/O Slave Auto Bottom On On -<br />
<br />
CN-CC<br />
CN-PIPE2<br />
90 Ceiling & Floor
5CSL0-06B<br />
Air flow and temperature distributions (reference data)<br />
1.2.6 Air flow and temperature distributions (reference data)<br />
Models : 5.0 kW - installation on ceilling<br />
Cooling Heating<br />
Discharge angle:45° Discharge angle:50°<br />
8m<br />
8m<br />
8m<br />
8m<br />
Air velocity [m/s]<br />
Air velocity [m/s]<br />
7m<br />
6m<br />
Temperature [˚C]<br />
7m<br />
7m<br />
6m<br />
6m<br />
Temperature [˚C]<br />
7m<br />
6m<br />
5m<br />
5m<br />
5m<br />
5m<br />
24<br />
24<br />
4m<br />
4m<br />
0.5<br />
4m<br />
4m<br />
0.5<br />
3m<br />
3m<br />
1.0<br />
3m<br />
22<br />
3m<br />
Models : 5.0 kW - installation on floor or wall<br />
2m<br />
2m<br />
1.5<br />
2m<br />
2m<br />
1.0<br />
22<br />
1.5<br />
2.0<br />
1m<br />
1m<br />
2.0<br />
1m<br />
18<br />
20<br />
1m<br />
Cooling Heating<br />
Discharge angle:45° Discharge angle:50°<br />
18<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
Air velocity [m/s]<br />
Ceiling & Floor 91<br />
8m<br />
8m<br />
8m<br />
8m<br />
Air velocity [m/s]<br />
7m<br />
6m<br />
Temperature [˚C]<br />
7m<br />
7m<br />
6m<br />
6m<br />
Temperature [˚C]<br />
21<br />
7m<br />
6m<br />
5m<br />
5m<br />
5m<br />
5m<br />
24<br />
4m<br />
4m<br />
4m<br />
4m<br />
24<br />
0.5<br />
3m<br />
0.5<br />
3m<br />
3m<br />
3m<br />
27<br />
2m<br />
2m<br />
2m<br />
2m<br />
1.0<br />
27<br />
1.0<br />
1m<br />
1m<br />
1m<br />
30<br />
1.5<br />
33<br />
2.0<br />
1.5<br />
1m<br />
2.0<br />
33<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m
Sound levels<br />
1.2.7 Sound levels<br />
Overall<br />
Sound Pressure Level (dB re 20 Pa )<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
Microphone<br />
1m<br />
1m<br />
20<br />
NC-25<br />
NC-20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Notes:<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
Sound pressure level<br />
AVNH09GELAD[UV09 NED]<br />
AVNH12GELAD[UV12 NED] UVNH186BLAD [UV18 NBD] UVNH246BLAD [UV24 NBD]<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
UVNH306BLAD [UV30 NBD]<br />
Octave Band Center Frequency (Hz)<br />
5CSL0-06B<br />
92 Ceiling & Floor<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
20<br />
NC-25<br />
NC-20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000
5CSL0-06B Controller<br />
1.2.8 Controller<br />
■ Wireless remote controller<br />
The remote controller transmits the signals to the system.<br />
CANCEL<br />
ON OFF SET<br />
AUTO CLEAN<br />
Cooling operation<br />
Auto operation<br />
Healthy dehumidification operation<br />
Heating operation<br />
Signal transmitter<br />
5 1<br />
6<br />
3<br />
4<br />
2<br />
7<br />
11<br />
8<br />
13<br />
14<br />
Operation mode<br />
10<br />
9<br />
12<br />
15<br />
Flip-up door<br />
(opened)<br />
• Cooling model( ), Heat pump model( )<br />
1. Start/Stop btton<br />
Operation starts when this button is pressed<br />
and stops when the button is pressed again.<br />
2. Operation mode selection button<br />
Used to select the operation mode.<br />
3. Room temperature setting buttons<br />
Used to select the room temperature.<br />
4. Indoor fanspeed selector<br />
Used to select fan speed in four steps<br />
low, medium, high and CHAOS.<br />
5. Jet cool<br />
Used to start or stop the speed cooling/heating.<br />
(Speed cooling/heating operates super high fan<br />
speed.)<br />
6. Chaos swing button<br />
Used to stop or start louver movement and set<br />
the desired up/down airflow direction.<br />
7. On/Off timer buttons<br />
Used to set the time <strong>of</strong> starting and stopping<br />
operation.<br />
8. Time setting buttons<br />
Used to adjust the time.<br />
9. Timer set/Cancel button<br />
Used to set the timer when the desired time is<br />
obtained and to cancel the Timer operation.<br />
10. Sleep mode auto button<br />
Used to set sleep mode auto operation.<br />
11. Air circulation button<br />
Used to circulate the room air without cooling or<br />
heating.<br />
12. Room temperature checking button<br />
Used to check the room temperature.<br />
13. PLASMA(Optional)<br />
Used to start or stop the <strong>pl</strong>asma-purification<br />
function.<br />
14. Reset button<br />
Initialize remote controller.<br />
15. 2nd F button<br />
Used prior to using modes printed in blue at the<br />
bottom <strong>of</strong> buttons.<br />
Ceiling & Floor 93<br />
(Heat Pump)
List <strong>of</strong> functions 5CSL0-06B<br />
1.3 Ceiling suspended<br />
1.3.1 List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Deluxe wired remote controller<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
UVNH366KLAD<br />
[UV36 NKD]<br />
UVNH426LLAD<br />
[UV42 NLD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
UVNH486LLAD<br />
[UV48 NLD]<br />
UVNH606LLAD<br />
[UV60 NLD]<br />
1 1 1 1<br />
Manual Manual Manual Manual<br />
Auto Auto Auto Auto<br />
- - - -<br />
O O O O<br />
3 / 4 / 3 3 / 4 / 3 3 / 4 / 3 3 / 4 / 3<br />
X X X X<br />
O O O O<br />
O O O O<br />
- - - -<br />
- - - -<br />
- - - -<br />
O O O O<br />
- - - -<br />
- - - -<br />
- - - -<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
- - - -<br />
X X X X<br />
O O O O<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
O O O O<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
O O O O<br />
O O O O<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
PVRCUSZ0 PVRCUSZ0 PVRCUSZ0 PVRCUSZ0<br />
X X X X<br />
X X X X<br />
X X X X<br />
X X X X<br />
O O O O<br />
X X X X<br />
PQDSB PQDSB PQDSB PQDSB<br />
O O O O<br />
X X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X X<br />
X X X X<br />
PQRSTA0 PQRSTA0 PQRSTA0 PQRSTA0<br />
94 Ceiling suspended
5CSL0-06B<br />
1.3.2 Specifications<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions (WxHxD) Body mm<br />
Weight Body kg<br />
Air Filter<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Refrigerant<br />
Refrigerant Control<br />
Indoor unit type Ceiling suspended<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 Specifications<br />
Model UVNH366KLAD [UV36 NKD] UVNH426LLAD [UV42 NLD]<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.97 0.67*2<br />
Induction Induction<br />
sirocco sirocco<br />
94.5 63*4<br />
29 / 27 / 24 32 / 30 / 28<br />
4.0 / 440 4.0 / 440<br />
Direct Drive Direct Drive<br />
3R*14C*19 3R*14C*19<br />
1,350*630*220 1,750*630*220<br />
35 45<br />
Long life filter Long life filter<br />
44 / 42 / 40 48 / 45 / 42<br />
9.52 9.52<br />
15.88 15.88<br />
20 / 17 20 / 17<br />
3.5 4.5<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Ceiling suspended 95
Specifications 5CSL0-06B<br />
Indoor unit type Ceiling suspended<br />
Model UVNH486LLAD [UV48 NLD] UVNH606LLAD [UV60 NLD]<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
Capacitor<br />
Drive<br />
μF/Vac<br />
Coil Row x Column x FPI mm<br />
Dimensions (WxHxD) Body mm<br />
Weight<br />
Air Filter<br />
Body kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate<br />
Safety devices<br />
Temperature Sensor<br />
Refrigerant<br />
Refrigerant Control<br />
Connectable outdoor unit<br />
l/h<br />
Power and transmission interunit cable No.x mm2 Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
0.67*2 0.67*2<br />
Induction Induction<br />
sirocco sirocco<br />
63*4 63*4<br />
36 / 34 / 32 40 / 38 / 36<br />
4.0 / 440 4.0 / 440<br />
Direct Drive Direct Drive<br />
3R*14C*19 3R*14C*19<br />
1,750*630*220 1,750*630*220<br />
45 45<br />
Long life filter Long life filter<br />
54 / 52 / 50 56 / 54 / 52<br />
9.52 9.52<br />
15.88 15.88<br />
20 / 17 20 / 17<br />
5.8 6.2<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
96 Ceiling suspended
5CSL0-06B<br />
1.3.3 Dimensions<br />
UVNH366KLAD[UV36 NKD]<br />
1<br />
Model name UVNH366KLAD[UV36 NKD]<br />
1 / 220-240 / 50<br />
9.52<br />
15.88<br />
20 / 17<br />
Dimensions<br />
Ceiling suspended 97<br />
Refer to each combination table<br />
10.0 kW
Dimensions 5CSL0-06B<br />
UVNH426LLAD[UV42 NLD]<br />
UVNH486LLAD[UV48 NLD]<br />
UVNH606LLAD[UV60 NLD]<br />
1<br />
UVNH606LLAD<br />
[UV60 NLD]<br />
1 / 220-240 / 50<br />
UVNH486LLAD<br />
[UV48 NLD]<br />
1 / 220-240 / 50<br />
UVNH426LLAD<br />
[UV42 NLD]<br />
1 / 220-240 / 50<br />
Model name<br />
9.52<br />
15.88<br />
20 / 17<br />
9.52<br />
15.88<br />
20 / 17<br />
9.52<br />
15.88<br />
20 / 17<br />
98 Ceiling suspended<br />
Refer to each combination table<br />
12.5/14.0/15.0 kW
5CSL0-06B<br />
1.3.4 Piping diagrams<br />
Heating<br />
Cooling<br />
Th2<br />
Heat exchanger<br />
C.F.F<br />
Th1 : Thermistor for suction air temp.<br />
Th2 : Thermistor for liquid line temp.<br />
Th3 : Thermistor for gas line temp.<br />
■ Refrigerant pipe connection port diameters<br />
Piping diagrams<br />
Ceiling suspended 99<br />
Th3<br />
Th1<br />
Gas pipe connection port<br />
(flare connection)<br />
Liquid pipe connection port<br />
(flare connection)<br />
Model Gas Liquid<br />
UVNH366KLAD[UV36 NKD]<br />
UVNH426LLAD[UV42 NLD]<br />
UVNH486LLAD[UV48 NLD]<br />
UVNH606LLAD[UV60 NLD]<br />
Ø15.88 Ø9.52<br />
[Unit:mm]
Wiring diagrams 5CSL0-06B<br />
1.3.5 Wiring diagrams<br />
1) Wiring diagrams<br />
Connector Number Location Connector Number Location<br />
CN-POWER AC power sup<strong>pl</strong>y CN-TH2 Discharge pipe sensor<br />
CN-MOTOR BLDC fan motor output CN-TH1 Pipe and room sensor<br />
CN-DPUMP Drain pump output CN-HVB Air cleaner<br />
CN-AC/DC AC/DC connector CN-DOOR Step motor<br />
CN-DISPLAY Dis<strong>pl</strong>ay CN-UD1 Step motor<br />
CN-FLOAT Float switch input CN-CC Central control<br />
2) PCB<br />
CN-POWER<br />
CN-MOTOR CN-DISP CN-REMO<br />
CN-FLOAT<br />
< UV36 NKD, UV42 NLD, UV48 NLD, UV60 NLD ><br />
CN-PIPE1<br />
CN-ROOM<br />
CN-CC<br />
CN-PIPE2<br />
100 Ceiling suspended
5CSL0-06B<br />
Air flow and temperature distributions (reference data)<br />
1.3.6 Air flow and temperature distributions (reference data)<br />
2.7m<br />
2m<br />
1m<br />
1<br />
0.5<br />
0.25<br />
3<br />
<br />
Air Flow Direction :10 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
2.5<br />
0.25<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
0.25<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
1<br />
0.25<br />
0.5<br />
4<br />
3.5<br />
0.25<br />
3<br />
2.5<br />
2<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
Models : 10.0 kW<br />
Models : 12.5 kW<br />
0.5<br />
0.25<br />
0.5<br />
0.25<br />
3<br />
3.5<br />
3<br />
1.5<br />
2<br />
1.5<br />
1<br />
1<br />
0.5<br />
0.5<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :45 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
2.5<br />
2<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
1.5<br />
1<br />
0.5<br />
0.25<br />
Ceiling suspended 101<br />
2.7m<br />
2m<br />
1m<br />
2.7m<br />
2m<br />
1m<br />
15<br />
32<br />
30<br />
28<br />
17<br />
16<br />
26<br />
19<br />
24<br />
21<br />
31<br />
22<br />
12<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :10 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
2.7m<br />
2m<br />
1m<br />
30<br />
28<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :45 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
0.25<br />
0.5<br />
2.7m<br />
34<br />
18<br />
2.5<br />
2<br />
1<br />
0.5 2m<br />
30<br />
28<br />
26<br />
1.5<br />
0.25<br />
1m<br />
14<br />
16<br />
18<br />
24<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
23<br />
20<br />
22<br />
20<br />
22<br />
20<br />
25<br />
24<br />
12<br />
29<br />
18<br />
26<br />
12<br />
27<br />
14<br />
14<br />
18<br />
16<br />
16<br />
28
Air flow and temperature distributions (reference data) 5CSL0-06B<br />
2.7m<br />
2m<br />
1m<br />
<br />
Air Flow Direction :10 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
0.25<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
0.5<br />
0.25<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
0.25<br />
0.5<br />
3<br />
3.5<br />
3<br />
0.25<br />
2.5<br />
2.5<br />
2<br />
0m<br />
0.5<br />
0.25<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
2.7m<br />
2m<br />
1m<br />
Models : 14.0 kW<br />
Models : 15.0 kW<br />
0.5<br />
0.25<br />
0.25<br />
0.5<br />
3.5<br />
3.5<br />
3<br />
1.5<br />
2<br />
1.5<br />
1<br />
1<br />
0.5<br />
0.5<br />
0.5<br />
0.25<br />
30 28<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :45 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
0m<br />
0.25<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
102 Ceiling suspended<br />
2.7m<br />
2m<br />
1m<br />
2.7m<br />
2m<br />
1m<br />
14<br />
32<br />
30<br />
18<br />
28<br />
16<br />
26<br />
18<br />
24<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :10 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
3<br />
2.5<br />
2 1.5 1<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
<br />
Air Flow Direction :45 °(downward)<br />
Air Velocity Distribution(m/s) Temperature Distribution(°C)<br />
0.25<br />
2.5<br />
2<br />
1.5<br />
1<br />
0.5<br />
0.5<br />
2.7m<br />
2m<br />
1m<br />
14<br />
32<br />
30<br />
28<br />
16<br />
26<br />
18<br />
12 16<br />
0m<br />
12<br />
0m 1m 2m 3m 4m 5m 6m 7m 8m<br />
24<br />
20<br />
20<br />
22<br />
30<br />
22<br />
18<br />
22<br />
22<br />
24<br />
20<br />
12<br />
24<br />
20<br />
28<br />
14<br />
14<br />
26<br />
16<br />
26<br />
26<br />
18<br />
18
5CSL0-06B<br />
1.3.7 Sound levels<br />
Overall<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
Microphone<br />
1m<br />
1m<br />
Sound Pressure Level<br />
Sound Pressure Level (dB re 20μPa )<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
10<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
UVNH366KLAD[UV36 NKD] UVNH426LLAD[UV42 NLD]<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
20<br />
NC-25<br />
NC-20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
Notes:<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
UVNH486LLAD[UV48 NLD] UVNH606LLAD[UV60 NLD]<br />
Sound Pressure Level (dB re 20μPa )<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound levels<br />
Ceiling suspended 103<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
Controller 5CSL0-06B<br />
1.3.8 Controller<br />
■ Wireless remote controller<br />
The remote controller transmits the signals to the system.<br />
CANCEL<br />
ON OFF SET<br />
AUTO CLEAN<br />
Cooling operation<br />
Auto operation<br />
Healthy dehumidification operation<br />
Heating operation<br />
Signal transmitter<br />
5 1<br />
6<br />
3<br />
4<br />
2<br />
7<br />
11<br />
8<br />
13<br />
14<br />
Operation mode<br />
10<br />
9<br />
12<br />
15<br />
Flip-up door<br />
(opened)<br />
• Cooling model( ), Heat pump model( )<br />
1. Start/Stop btton<br />
Operation starts when this button is pressed<br />
and stops when the button is pressed again.<br />
2. Operation mode selection button<br />
Used to select the operation mode.<br />
3. Room temperature setting buttons<br />
Used to select the room temperature.<br />
4. Indoor fanspeed selector<br />
Used to select fan speed in four steps<br />
low, medium, high and CHAOS.<br />
5. Jet cool<br />
Used to start or stop the speed cooling/heating.<br />
(Speed cooling/heating operates super high fan<br />
speed.)<br />
6. Chaos swing button<br />
Used to stop or start louver movement and set<br />
the desired up/down airflow direction.<br />
7. On/Off timer buttons<br />
Used to set the time <strong>of</strong> starting and stopping<br />
operation.<br />
8. Time setting buttons<br />
Used to adjust the time.<br />
9. Timer set/Cancel button<br />
Used to set the timer when the desired time is<br />
obtained and to cancel the Timer operation.<br />
10. Sleep mode auto button<br />
Used to set sleep mode auto operation.<br />
11. Air circulation button<br />
Used to circulate the room air without cooling or<br />
heating.<br />
12. Room temperature checking button<br />
Used to check the room temperature.<br />
13. PLASMA(Optional)<br />
Used to start or stop the <strong>pl</strong>asma-purification<br />
function.<br />
14. Reset button<br />
Initialize remote controller.<br />
15. 2nd F button<br />
Used prior to using modes printed in blue at the<br />
bottom <strong>of</strong> buttons.<br />
104 Ceiling suspended<br />
(Heat Pump)
5CSL0-06B<br />
1.4 Ceiling concealed duct – high static pressure<br />
1.4.1 List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Deluxe wired remote controller<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
ABNH186HLAD<br />
[UB18 NHD]<br />
ABNH246HLAD<br />
[UB24 NHD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
List <strong>of</strong> functions<br />
ABNH306GLAD<br />
[UB30 NGD]<br />
2 2 2<br />
- - -<br />
- - -<br />
- - -<br />
- - -<br />
3 / 3 / 3 3 / 3 / 3 3 / 3 / 3<br />
- - -<br />
- - -<br />
- - -<br />
- - -<br />
- - -<br />
X X X<br />
O O O<br />
ABDPG ABDPG ABDPG<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
X X X<br />
O O O<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQDSB** PQDSB** PQDSB**<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
ABZCA ABZCA ABZCA<br />
PQRSTA0 PQRSTA0 PQRSTA0<br />
Duct (H) 105
List <strong>of</strong> functions 5CSL0-06B<br />
Category<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Air flow Auto swing(up & down)<br />
Airflow steps(fan/cool/heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Air purifying Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Installation<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Reliability Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Convenience Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Deluxe wired remote controller<br />
Sim<strong>pl</strong>e wired remote controller<br />
Individual control<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
CAC network<br />
Sim<strong>pl</strong>e central control(LGAP)<br />
function<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Special function kit<br />
Zone control<br />
Others Thermistor<br />
ABNH366GLAD<br />
[UB36 NGD]<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
2 2 2 2<br />
- - - -<br />
- - - -<br />
- - - -<br />
- - - -<br />
3 / 3 / 3 3 / 3 / 3 3 / 3 / 3 3 / 3 / 3<br />
- - - -<br />
- - - -<br />
- - - -<br />
- - - -<br />
- - - -<br />
X X X X<br />
O O O O<br />
ABDPG ABDPG ABDPG ABDPG<br />
O O O O<br />
- - - -<br />
- - - -<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
X X X X<br />
X X X X<br />
O O O O<br />
O O O O<br />
X X X X<br />
O O O O<br />
X X X X<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
X X X X<br />
X X X X<br />
X X X X<br />
X X X X<br />
X X X X<br />
X X X X<br />
PQDSB** PQDSB** PQDSB** PQDSB**<br />
O O O O<br />
X X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X X<br />
ABZCA ABZCA ABZCA ABZCA<br />
AQTTA AQTTA AQTTA AQTTA<br />
106 Duct (H)
5CSL0-06B<br />
1.4.2 Specifications<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
External Static Pressure mmAq<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Columns x FPI mm<br />
Dimensions(WxHxD) Body mm<br />
Weight Body kg<br />
Air Filter<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Ceilling Concealed Duct - High Static<br />
Model<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 ABNH186HLAD<br />
[UB18 NHD]<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
ABNH246HLAD<br />
[UB24 NHD]<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
Specifications<br />
0.92 0.92<br />
Induction Induction<br />
Sirocco Fan Sirocco Fan<br />
118*2 118*2<br />
16.5/14.5/13.0 18.0/16.5/14.0<br />
8 8<br />
6/370 6/370<br />
Direct Drive Direct Drive<br />
3R x 10C x 21 3R x 10C x 21<br />
880*260*450 880*260*450<br />
35 35<br />
Long life filter Long life filter<br />
36/34/32 38/36/34<br />
6.35 9.52<br />
12.7 15.88<br />
32/25 32/25<br />
2.0 2.5<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Duct (H) 107
Specifications 5CSL0-06B<br />
Indoor unit type Ceilling Concealed Duct - High Static<br />
Model ABNH306GLAD [UB30 NGD] ABNH366GLAD [UB36 NGD]<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
External Static Pressure mmAq<br />
Capacitor<br />
Drive<br />
μF/Vac<br />
Coil Row x Columns x FPI mm<br />
Dimensions(WxHxD) Body mm<br />
Weight<br />
Air Filter<br />
Body kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Connectable outdoor unit<br />
l/h<br />
Power and transmission interunit cable No.x mm2 Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
1.34 1.42<br />
Induction Induction<br />
Sirocco Fan Sirocco Fan<br />
211*2 272*2<br />
26.5 / 23.0 / 20.0 32.0 / 29.0 / 26.0<br />
10 10<br />
6/370 6/370<br />
Direct Drive Direct Drive<br />
3R x 12C x 21 3R x 12C x 21<br />
1,180*298*450 1,180*298*450<br />
38 38<br />
Long life filter Long life filter<br />
40/38/35 42/39/36<br />
9.52 9.52<br />
15.88 15.88<br />
32/25 32/25<br />
3.3 4.0<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
108 Duct (H)
5CSL0-06B<br />
Indoor unit type Ceilling Concealed Duct - High Static<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
External Static Pressure mmAq<br />
Capacitor<br />
Drive<br />
μF/Vac<br />
Coil Row x Columns x FPI mm<br />
Dimensions(WxHxD) Body mm<br />
Weight<br />
Air Filter<br />
Body kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Connectable outdoor unit<br />
l/h<br />
Power and transmission interunit cable No.x mm2 Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Specifications<br />
Model ABNH426RLAD [UB42 NRD] ABNH486RLAD [UB48 NRD]<br />
1 / 220-240 / 50 1 / 220-240 / 50<br />
Refer to each combination table<br />
3.65 3.65<br />
Induction Induction<br />
Sirocco Fan Sirocco Fan<br />
357*2 357*2<br />
36/32/38 40/35/30<br />
10 15<br />
15/450 15/450<br />
Direct Drive Direct Drive<br />
3R x 13C x 19 3R x 13C x 19<br />
1,230*380*590 1,230*380*590<br />
60 60<br />
Long life filter Long life filter<br />
42/40/38 44/42/40<br />
9.52 9.52<br />
15.88 15.88<br />
32/25 32/25<br />
5.0 6.0<br />
Fuse, Thermal protector for fan motor<br />
Thermistor Thermistor<br />
R410A R410A<br />
EEV(Outdoor Unit) EEV(Outdoor Unit)<br />
Single A Single A<br />
4*0.75(Including Earth) 4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Duct (H) 109
Specifications 5CSL0-06B<br />
Indoor unit type Ceilling Concealed Duct - High Static<br />
Model ABNH606RLAD [UB60 NRD]<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L) cmm<br />
External Static Pressure mmAq<br />
Capacitor<br />
Drive<br />
μF/Vac<br />
Coil Row x Columns x FPI mm<br />
Dimensions(WxHxD) Body mm<br />
Weight<br />
Air Filter<br />
Body kg<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Connectable outdoor unit<br />
l/h<br />
Power and transmission interunit cable No.x mm2 Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
1/220-240 / 50<br />
Refer to each combination table<br />
3.65<br />
Induction<br />
Sirocco Fan<br />
357*2<br />
50/45/40<br />
15<br />
15/450<br />
Direct Drive<br />
4Rx13Cx19<br />
1,230*380*590<br />
62<br />
Long life filter<br />
46/44/42<br />
9.52<br />
15.88<br />
32/25<br />
6.5<br />
Fuse, Thermal protector for fan motor<br />
Thermistor<br />
R410A<br />
EEV(Outdoor Unit)<br />
Single A<br />
4*0.75(Including Earth)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
110 Duct (H)
5CSL0-06B<br />
1.4.3 Dimensions<br />
ABNH186HLAD[UB18 NHD]<br />
ABNH246HLAD[UB24 NHD]<br />
ABNH246HLAD[UB24 NHD]<br />
1 / 220-240 / 50<br />
Model name ABNH186HLAD[UB18 NHD]<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
6.35<br />
12.7<br />
32/25<br />
Dimensions<br />
Duct (H) 111<br />
9.52<br />
15.88<br />
32/25<br />
5.0/7.1 kW
Dimensions 5CSL0-06B<br />
ABNH306GLAD[UB30 NGD]<br />
ABNH366GLAD[UB36 NGD]<br />
ABNH366GLAD[UB36 NGD]<br />
1 / 220-240 / 50<br />
Model name ABNH306GLAD[UB30 NGD]<br />
1/ 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
32 / 35<br />
9.52<br />
15.88<br />
32 / 35<br />
112 Duct (H)<br />
8.0/10.0 kW
5CSL0-06B<br />
ABNH426RLAD[UB42 NRD]<br />
ABNH486RLAD[UB48 NRD]<br />
ABNH606RLAD[UB60 NRD]<br />
ABNH426RLAD[UB42 NRD]<br />
ABNH486RLAD[UB48 NRD]<br />
ABNH606RLAD[UB60 NRD]<br />
Model name<br />
Dimensions<br />
Duct (H) 113<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
COMBINATION TABLE<br />
9.52<br />
15.88<br />
32/25<br />
12.5/14.0/15.0 kW
Piping diagrams 5CSL0-06B<br />
1.4.4 Piping diagrams<br />
Heating<br />
Cooling<br />
Th2<br />
Heat exchanger<br />
Sirocco Fan<br />
Th1 : Thermister for suction air temp.<br />
Th2 : Thermister for liquid line temp.<br />
Th3 : Thermister for gas line temp.<br />
■ Refrigerant pipe connection port diameters<br />
M<br />
Th3<br />
114 Duct (H)<br />
Th1<br />
Gas pipe connection port<br />
(flare connection)<br />
Liquid pipe connection port<br />
(flare connection)<br />
Model Gas Liquid<br />
ABNH186HLAD[UB18 NHD]<br />
ABNH246HLAD[UB24 NHD]<br />
ABNH306GLAD[UB30 NGD]<br />
Ø12.7 Ø6.35<br />
ABNH366GLAD[UB36 NGD]<br />
ABNH426RLAD[UB42 NRD]<br />
Ø15.88 Ø9.52<br />
ABNH486RLAD[UB48 NRD]<br />
ABNH606RLAD[UB60 NRD]<br />
[Unit:mm]
5CSL0-06B<br />
1.4.5 Wiring diagrams<br />
1) Wiring diagrams<br />
Models : ABNH186HLAD[UB18 NHD], ABNH246HLAD[UB24 NHD]<br />
Models : ABNH306GLAD[UB30 NGD], ABNH366GLAD[UB36 NGD]<br />
Connector Number Location<br />
CN-POWER AC power sup<strong>pl</strong>y<br />
CN-MOTOR BLDC fan motor outpup<br />
CN-D/PUMP Drain pump output<br />
CN-DISP RF-remote control<br />
CN-FLOAT Float switch input<br />
CN-ZONE Zone control output<br />
CN-CC Central control ouput<br />
Connector Number Location<br />
CN-PIPE1 Pipe sensor<br />
CN-PIPE2 Dischage pipe sensor<br />
CN-REMO Remote control<br />
CN-ROOM Room sensor<br />
CN-AIRC Air clean<br />
CN-PTC PTC heater<br />
CN-OUT Ventilation/Electric heater<br />
Wiring diagrams<br />
Duct (H) 115
Wiring diagrams 5CSL0-06B<br />
Models: ABNH426RLAD [UB42 NRD], ABNH486RLAD [UB48 NRD], ABNH606RLAD [UB60 NRD]<br />
Connector Number Location<br />
CN-POWER AC power sup<strong>pl</strong>y<br />
CN-MOTOR BLDC fan motor outpup<br />
CN-D/PUMP Drain pump output<br />
CN-DISP RF-remote control<br />
CN-FLOAT Float switch input<br />
CN-ZONE Zone control output<br />
CN-CC Central control ouput<br />
Connector Number Location<br />
CN-PIPE1 Pipe sensor<br />
CN-PIPE2 Dischage pipe sensor<br />
CN-REMO Remote control<br />
CN-ROOM Room sensor<br />
CN-AIRC Air clean<br />
CN-PTC PTC heater<br />
CN-OUT Ventilation/Electric heater<br />
116 Duct (H)
5CSL0-06B<br />
2) PCB<br />
CN-ZONE<br />
CN-FLOAT<br />
CN-PIPE2<br />
CN-ZONE<br />
CN-FLOAT<br />
CN-CC CN-ROOM<br />
CN-FLOAT<br />
CN-REMO<br />
CN-PIPE2<br />
CN-REMO<br />
CN-ROOM<br />
CN-CC CN-PIPE2<br />
CN-PIPE1<br />
CN-STEP<br />
CN-DPUMP CN-POWER<br />
CN-MOTOR<br />
<br />
CN-MOTOR<br />
CN-DPUMP<br />
<br />
Wiring diagrams<br />
CN-POWER<br />
Duct (H) 117
External pressure setting for tuning 5CSL0-06B<br />
1.4.6 External pressure setting for<br />
(ESP Control) provide required constant air volume irrespective <strong>of</strong> ESP charge.<br />
(1) Open the rear cover <strong>of</strong> the wired remote-controller to set the mode.<br />
(2) Select one <strong>of</strong> three selectable modes as follows.<br />
■ Without zone system<br />
1. Position V-H, F-H:<br />
• This position sets the maximum ESP as a default set.<br />
2. Position V-L:<br />
• This position sets the minimum ESP as a default set.<br />
■ With zone system<br />
1. Position V-H:<br />
• Maximum ESP setting & Fan speed is varied according to the state <strong>of</strong> dampers by micom.<br />
2. Position F-H:<br />
• Maximum ESP setting & Fan speed doesn't vary according to the opening & closing <strong>of</strong> dampers.<br />
3. Position V-L:<br />
• Minimum ESP setting & Fan speed is varied according to the state <strong>of</strong> dampers by micom.<br />
Static pressure RECOMMENDATION : NORMAL SET ±2<br />
Static pressure guide (Unit : mmAq)<br />
MODELS MIN NORMAL SET MAX<br />
UB18,UB24 0 4 8<br />
UB30,UB36 0 4 10<br />
UB42,UB48,UB60 0 8 15<br />
(3) Move the slide switch to set position.<br />
(4) Close the rear cover and check if it works normally.<br />
CAUTION<br />
V-L<br />
F-H<br />
V-H<br />
Zone state / Default E.S.P<br />
• Select the position after checking duct work and ESP <strong>of</strong> the unit.<br />
• Maunfactured in the position F-H.<br />
TH R13H R12H OP5R16H OP4<br />
CO1H<br />
118 Duct (H)<br />
R14H<br />
SW TH<br />
OP3 OP2 OP1<br />
REMO<br />
MAIN<br />
2TH<br />
OP7<br />
R18H<br />
R17H<br />
OP6<br />
LO<br />
STAND<br />
HI R03S<br />
SW HIGH<br />
R19H<br />
R11H<br />
C070 R04S<br />
R02S<br />
R01S<br />
R15H
5CSL0-06B<br />
How to Set ESP on the remote controller?<br />
Procedure <strong>of</strong> RPM change:<br />
Ex) External static pressure is 4mmAq for model name "ABNH246HLAD".<br />
• To protect the unit, compressor is designed to be <strong>of</strong>f during ESP setting.<br />
1<br />
2<br />
3<br />
Push the "On/Off" button.<br />
The unit will start.<br />
Push the "Timer" and "Wind" button simultaneously for more than<br />
3 seconds.<br />
Timer<br />
Push the "Up" <strong>of</strong> "Down" button for ESP adjustment.<br />
And, adjust the number which you want.(In this exam<strong>pl</strong>e, the number is "190".<br />
Refer to the table on the next <strong>page</strong>.)<br />
Shift the fan speed mode by pressing the fan speed button.<br />
And then, adjust numbers <strong>of</strong> next steps by repeating the stage 3.<br />
(In this exam<strong>pl</strong>e, the numbers are "220" and "235" respectively.<br />
Push the "Timer" and "Wind" button simultaneously for more than 3 seconds.<br />
Then, wind data is memorized by the EEPROM <strong>of</strong> the main PCB.<br />
External pressure setting for tuning<br />
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION<br />
Room Temp<br />
HI AUTO Heater Preheat<br />
MED JET Defrost Humidify<br />
LO<br />
Filter Out door<br />
Time ZONE 1 2 3 4<br />
Timer Operation unit Program set<br />
On Off<br />
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23<br />
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION<br />
Room Temp<br />
HI AUTO Heater Preheat<br />
MED JET Defrost Humidify<br />
LO<br />
Filter Out door<br />
Time ZONE 1 2 3 4<br />
Timer Operation unit Program set<br />
On Off<br />
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23<br />
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION<br />
Room Temp<br />
HI AUTO Heater Preheat<br />
MED JET Defrost Humidify<br />
LO<br />
Filter Out door<br />
Time ZONE 1 2 3 4<br />
Timer Operation unit Program set<br />
On Off<br />
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23<br />
Note: The range <strong>of</strong> selection is from 1~254. Since, the dis<strong>pl</strong>ay is two digit only.<br />
If the range selection is above 100 then the third digit will appear in the screen as shown.(setting value)<br />
4<br />
5<br />
Timer<br />
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION<br />
Room Temp<br />
HI AUTO Heater Preheat<br />
MED JET Defrost Humidify<br />
LO<br />
Filter Out door<br />
Time ZONE 1 2 3 4<br />
Timer Operation unit Program set<br />
On Off<br />
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23<br />
Duct (H) 119
External pressure setting for tuning 5CSL0-06B<br />
Table 1<br />
[ Notes ]<br />
Static Pressure(mmAq)<br />
Model Name Step CMM<br />
ABNH186HLAD<br />
[UB18 NHD]<br />
ABNH246HLAD<br />
[UB24 NHD]<br />
ABNH306GLAD<br />
[UB30 NGD]<br />
ABNH366GLAD<br />
[UB36 NGD]<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
0 2 4 6 8<br />
Setting Value<br />
10 12 14 15<br />
High 16.5 235 230 225 215 180 - - - -<br />
Med 14.5 245 238 235 230 215 - - - -<br />
Low 13 254 252 248 245 240 - - - -<br />
High 18 220 205 190 50 1 - - - -<br />
Med 16.5 235 230 220 200 100 - - - -<br />
Low 14 250 240 235 230 210 - - - -<br />
High 26.5 153 150 150 148 130 1 - - -<br />
Med 23 173 173 175 175 170 155 - - -<br />
Low 20 190 190 190 190 190 190 - - -<br />
High 32 230 230 225 220 150 1 - - -<br />
Med 29 240 238 237 235 230 220 - - -<br />
Low 26.5 245 245 243 243 240 240 - - -<br />
High 36 238 235 230 225 220 215 - - -<br />
Med 32 253 250 245 240 235 230 - - -<br />
Low 28 255 255 255 255 250 248 - - -<br />
High 40 230 225 220 215 205 200 190 180 160<br />
Med 35 250 245 240 235 230 220 215 210 200<br />
Low 30 255 255 255 250 245 240 235 230 225<br />
High 50 185 180 174 162 154 140 90 5 1<br />
Med 45 210 205 199 191 189 180 155 138 110<br />
Low 40 230 225 219 215 210 205 193 180 171<br />
1. To get the desired Airflow & ESP combination from the table set the matching value from the table. Value<br />
other than that in table will not give the combinations <strong>of</strong> airflow & ESP which are mentioned in the table.<br />
2. Table data is based at 230V. According to the fluctuation <strong>of</strong> voltage, air flow rate varies.<br />
3) Duct work must be designed within the range <strong>of</strong> on installing the unit.<br />
4) If duct work is designed under External Static Pressure adjust the External Static Pressure ap<strong>pl</strong>ying<br />
air damper.<br />
120 Duct (H)
5CSL0-06B<br />
Table 2<br />
[ Notes ]<br />
External pressure setting for tuning<br />
Static Pressure(mmAq)<br />
Model Name Step 0 2 4 6 8<br />
CMM<br />
10 12 14 15<br />
Setting<br />
Value<br />
ABNH186HLAD<br />
[UB18 NHD]<br />
High<br />
Med<br />
180<br />
215<br />
22<br />
18.5<br />
21<br />
17.8<br />
19.8<br />
17.1<br />
18.3<br />
16.2<br />
16.5<br />
14.5<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Low 240 16.1 15.6 15.1 14.2 13 - - - -<br />
ABNH246HLAD<br />
[UB24 NHD]<br />
High<br />
Med<br />
1<br />
100<br />
24<br />
21.3<br />
22.5<br />
19.9<br />
20.8<br />
18.7<br />
19<br />
17.2<br />
18<br />
16.5<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Low 210 17 16.1 15.4 14.7 14 - - - -<br />
ABNH306GLAD<br />
[UB30 NGD]<br />
High<br />
Med<br />
1<br />
155<br />
34.2<br />
27<br />
33.1<br />
26.3<br />
31.7<br />
26.1<br />
29.9<br />
25.8<br />
27.7<br />
24.8<br />
26.5<br />
23<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
Low 190 21 20.8 20.6 20.4 20.4 20 - - -<br />
High 1 42 40 38 35.5 33.5 32 - - -<br />
ABNH366GLAD<br />
[UB36 NGD]<br />
Med<br />
Low<br />
220<br />
240<br />
39<br />
34<br />
37<br />
32.5<br />
35<br />
31<br />
33<br />
29.5<br />
31<br />
27<br />
29<br />
26.5<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
High 215 44.5 43.4 41 39.4 37.5 36.4 - - -<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
Med<br />
Low<br />
230<br />
248<br />
41<br />
37<br />
40.2<br />
36.1<br />
37.6<br />
34.6<br />
35<br />
31.5<br />
33.8<br />
29.1<br />
32.7<br />
27.9<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
High 200 49 47.4 44.9 43.3 41.7 40 38.6 37 35.4<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
Med<br />
Low<br />
220<br />
240<br />
44<br />
38<br />
42.4<br />
37.2<br />
40.2<br />
35<br />
39.2<br />
32.4<br />
36.7<br />
31.6<br />
35<br />
30<br />
34.6<br />
28.6<br />
33<br />
27<br />
32.2<br />
26.2<br />
High 140 59 57.4 55.8 53.4 51.7 50 46.6 42.9 40.6<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
Med<br />
Low<br />
180<br />
205<br />
53<br />
47<br />
51.4<br />
45.8<br />
49.8<br />
43.8<br />
47.4<br />
42.1<br />
45.9<br />
40.7<br />
45<br />
40<br />
42.6<br />
37.8<br />
39.6<br />
35<br />
38.3<br />
33.4<br />
1) The above table shows the correlation <strong>of</strong> External Static Pressure & Air Flow.<br />
2) When installing, the value <strong>of</strong> motor step needs to be set according to E.S.P. <strong>of</strong> the table 2.<br />
3) Duct work must be designed within the range <strong>of</strong> on installing the unit.<br />
4) If duct work is designed under External Static Pressure adjust the External Static Pressure ap<strong>pl</strong>ying<br />
air damper.<br />
Duct (H) 121
Sound levels 5CSL0-06B<br />
1.4.7 Sound levels<br />
overall<br />
DISCHARGE SUCTION<br />
DUCT<br />
2m<br />
1.5m<br />
1m<br />
1m<br />
Sound pressure level<br />
Sound Pressure Level (dB re 20μPa )<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
DUCT<br />
Notes:<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
ABNH186HLAD[UB18 NHD] ABNH246HLAD[UB24 NHD] ABNH306GLAD[UB30 NGD]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
ABNH366GLAD[UB36 NGD] ABNH426RLAD[UB42 NRD] ABNH486RLAD[UB48 NRD]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
122 Duct (H)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20μPa )<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
5CSL0-06B<br />
Sound Pressure Level (dB re 20μPa )<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
ABNH606RLAD[UB60 NRD]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound levels<br />
Duct (H) 123
Controller 5CSL0-06B<br />
1.4.8 Controller<br />
Wired remote controller<br />
3<br />
Signal receiver<br />
5<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
AUTO SWING OPERATION SET TEMP FAN SPEED SUB FUNCTION<br />
Room Temp<br />
HI AUTO Heater Preheat<br />
MED JET Defrost Humidify<br />
LO<br />
Filter Out door<br />
Time ZONE 1 2 3 4<br />
Timer Operation unit<br />
Program set<br />
On Off<br />
Set no. Time 01 03 05 07 09 11 13 15 17 19 21 23<br />
Timer Cancel<br />
Program Week Holiday<br />
Hour<br />
Min<br />
SET/CLR<br />
1. Operation dis<strong>pl</strong>ay<br />
Dis<strong>pl</strong>ays the operation conditions.<br />
2. On/Off button<br />
Operation starts when this button is pressed, and<br />
stops when the button is pressed again.<br />
3. Set temperature button<br />
Used to set the temperature when the desired temperature<br />
is obtained.<br />
4. FAN operation button<br />
Used to circulate room air without cooling or heating.<br />
5. Electric heater button(Optional)<br />
Used to set the electric heater.<br />
6. Fan speed button<br />
Used to set desired fan speed.<br />
7. Operation mode selection button<br />
Used to select the operation mode.<br />
• Auto operation or Auto changeover mode.<br />
• Cooling operation mode.<br />
• S<strong>of</strong>t dry operation mode.<br />
• Heating operation mode.(except cooling model)<br />
8. Timer cancel button<br />
Used to cancel the timer.<br />
Plasma<br />
RESET<br />
124 Duct (H)<br />
1<br />
2<br />
6<br />
7<br />
4<br />
15<br />
16<br />
17<br />
9. Timer set button<br />
Used to set the timer when the desired time is<br />
obtained.<br />
10. Week button<br />
Used to set a day <strong>of</strong> the week.<br />
11. Program button<br />
Used to set the weekly timer.<br />
12. Holiday button<br />
Used to set a holiday <strong>of</strong> the week.<br />
13. Time set button<br />
Used to set the time <strong>of</strong> the day and change the<br />
time in the weekly timer Function.<br />
14. Set and clear button<br />
Used to set and clear the weekly timer.<br />
15. Room temperature checking button<br />
Used to check the room temperature.<br />
16. Plasma air clean button(Accessory)<br />
17. Reset button<br />
Used to set the current time and clear the setting<br />
time.<br />
❈ Dis<strong>pl</strong>ay temperature can be different from actual room temperature if the remote controller is installed at the <strong>pl</strong>ace where<br />
sun-rays are falling directly or the <strong>pl</strong>ace nearby heat source.
5CSL0-06B<br />
1.5 Console (Floor stand)<br />
1.5.1 List <strong>of</strong> functions<br />
Category<br />
Air flow<br />
Air purifying<br />
Installation<br />
Reliability<br />
Convenience<br />
Individual<br />
control<br />
CAC network<br />
function<br />
Special<br />
function kit<br />
Others<br />
Function<br />
Air sup<strong>pl</strong>y outlet<br />
Airflow direction control(left & right)<br />
Airflow direction control(up & down)<br />
Auto swing(left & right)<br />
Auto swing(up & down)<br />
Airflow steps(fan / cool / heat)<br />
Chaos swing<br />
Chaos wind(auto wind)<br />
Jet cool(Power wind)<br />
Swirl wind<br />
Deodorizing filter<br />
Plasma air purifier<br />
Prefilter(washable / anti-fungus)<br />
Drain pump<br />
E.S.P. control<br />
Electric heater(operation)<br />
High ceiling operation<br />
Hot start<br />
Self diagnosis<br />
S<strong>of</strong>t dry operation<br />
Auto changeover<br />
Auto cleaning<br />
Auto operation(artificial intelligence)<br />
Auto restart operation<br />
Child lock<br />
Forced operation<br />
Group control<br />
Sleep mode<br />
Timer(on/<strong>of</strong>f)<br />
Timer(weekly)<br />
Two thermistor control<br />
Standard wired remote controller<br />
Picto wired remote controlxer<br />
Deluxe wired remote controlxer<br />
Sim<strong>pl</strong>e wired remote controller<br />
Wired remote controller(for hotel use)<br />
Wireless remote controller(sim<strong>pl</strong>e)<br />
Wireless LCD remote control<br />
General central control(Non LGAP)<br />
Dry contact<br />
Network Soluation(LGAP)<br />
PDI(power distribution indicator)<br />
PI 485<br />
CTIE<br />
Zone control<br />
Thermistor<br />
AQNH09GALA0<br />
[CQ09 NA0]<br />
AQNH12GALA0<br />
[CQ12 NA0]<br />
Note:<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
List <strong>of</strong> functions<br />
AQNH18GALA0<br />
[CQ18 NA0]<br />
2 2 2<br />
Manual Manual Manual<br />
Auto Auto Auto<br />
X X X<br />
O O O<br />
4/5/4 4/5/4 4/5/4<br />
X X X<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
X X X<br />
O O O<br />
X X X<br />
- - -<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
X X X<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
X X X<br />
PQRCUSA1 PQRCUSA1 PQRCUSA1<br />
X X X<br />
X X X<br />
X X X<br />
X X X<br />
PQWRHSF0 PQWRHSF0 PQWRHSF0<br />
X X X<br />
PQDSB PQDSB PQDSB<br />
O O O<br />
X X X<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
X X X<br />
X X X<br />
X X X<br />
Console 125
Specifications 5CSL0-06B<br />
1.5.2 Specifications<br />
Power Sup<strong>pl</strong>y Ø/V/Hz<br />
Cooling Capacity kW<br />
Heating Capacity kW<br />
Current Nominal running current A<br />
Fan Motor Type<br />
Fan Type<br />
Motor Output x Number <strong>of</strong> Unit<br />
Air Flow Rate(H/M/L/Sleep) cmm<br />
Capacitor μF/Vac<br />
Drive<br />
Coil Row x Column x FPI mm<br />
Dimensions (WxHxD) Body mm<br />
Weight Body kg<br />
Air Filter<br />
Sound Level (H/M/L) dB(A)+3<br />
Piping Liquid mm<br />
Connections Gas mm<br />
Drain(OD/ID) mm<br />
Dehumidification Rate l/h<br />
Safety devices<br />
Temperature Sensor<br />
Referigerant<br />
Referigerant Control<br />
Indoor unit type Console (Floor stand)<br />
Model<br />
Connectable outdoor unit<br />
Power and transmission interunit cable No.x mm2 AQNH09GALA0<br />
[CQ09 NA0]<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />
3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
AQNH12GALA0<br />
[CQ12 NA0]<br />
AQNH18GALA0<br />
[CQ18 NA0]<br />
1 / 220-240V / 50 1 / 220-240V / 50 1 / 220-240V / 50<br />
Refer to each combination table<br />
0.14 0.14 0.18<br />
BLDC BLDC BLDC<br />
Turbo Turbo Turbo<br />
48 x 1 48 x 1 48 x 1<br />
8.5/6.7/5.0/4.0 9.0/6.9/5.2/4.6 11.0/9.5/8.0/6.5<br />
- - -<br />
Direct Direct Direct<br />
2 x 19 x 19 2 x 19 x 19 2 x 19 x 19<br />
700 x 600 x 210 700 x 600 x 210 700 x 600 x 210<br />
13.8 13.8 13.8<br />
Long Life Filter Long Life Filter Long Life Filter<br />
38/32/27/22 39/32/27/23 44/39/35/32<br />
6.35 6.35 6.35<br />
9.52 9.52 12.7<br />
16.7/9.7 16.7/9.7 16.7/9.7<br />
1.2 1.4 2<br />
Fuse, Thermal Protector for Fan Motor<br />
Thermistor Thermistor Thermistor<br />
R410A, 1000g R410A, 1000g R410A, 1300g<br />
EEV (ODU) EEV (ODU) EEV (ODU)<br />
AUUW096D AUUW126D AUUW186D<br />
4 x 0.75 4 x 0.75 4 x 0.75<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
126 Console
5CSL0-06B<br />
1.5.3 Dimensions<br />
Console (Floor stand)<br />
AQNH09GALA0[CQ09 NA0]<br />
AQNH12GALA0[CQ12 NA0]<br />
AQNH18GALA0[CQ18 NA0]<br />
666<br />
45<br />
95<br />
2<br />
210<br />
700<br />
1<br />
AQNH18GALA0<br />
[CQ18 NA0]<br />
1 / 220-240 / 50<br />
AQNH12GALA0<br />
[CQ12 NA0]<br />
1 / 220-240 / 50<br />
REFER TO EACH<br />
AQNH09GALA0<br />
[CQ09 NA0]<br />
1 / 220-240 / 50<br />
Model name<br />
600<br />
584<br />
COMBINATION TABLE<br />
6.35<br />
9.52<br />
16.7/9.7<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
mm<br />
Power sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Piping Liquid<br />
Connections Gas<br />
Drain(OD/ID)<br />
3<br />
Dimensions<br />
Console 127<br />
6.35<br />
12.7<br />
16.7/9.7<br />
6.35<br />
9.52<br />
16.7/9.7<br />
1<br />
90<br />
125<br />
80<br />
18<br />
639<br />
82.5<br />
150<br />
140<br />
120<br />
160<br />
80<br />
68.5<br />
37<br />
37<br />
100<br />
CHASSIS CODE: QA<br />
2.5/3.5/5.0 kW
Piping diagrams 5CSL0-06B<br />
1.5.4 Piping diagrams<br />
Heating<br />
Cooling<br />
Th2<br />
Heat exchanger<br />
Turbo fan<br />
Th1 : Thermistor for suction air temp.<br />
Th2 : Thermistor for liquid line temp.<br />
Th3 : Thermistor for gas line temp.<br />
■ Refrigerant pipe connection port diameters<br />
128 Console<br />
Th3<br />
Th1<br />
Gas pipe connection port<br />
(flare connection)<br />
Liquid pipe connection port<br />
(flare connection)<br />
Model Gas Liquid<br />
AQNH09GALA0[CQ09 NA0]<br />
AQNH12GALA0[CQ12 NA0]<br />
Ø9.52 Ø6.35<br />
AQNH18GALA0[CQ18 NA0] Ø12.7 Ø6.35<br />
[Unit:mm]
5CSL0-06B<br />
1.5.5 Wiring diagrams<br />
1) Wiring diagrams<br />
2) PCB<br />
■ Main PCB<br />
CN_PWR<br />
■ Dis<strong>pl</strong>ay PCB<br />
CN_MOTOR<br />
CN_VANE2<br />
SW01 CN_DISPLAY CN_OPTION<br />
CN_VANE1<br />
CN_CC<br />
CN_ROOM<br />
CN_PIPE/IN<br />
CN_PIPE/OUT<br />
CN_REMO<br />
Wiring diagrams<br />
Console 129
Air flow and temperature distributions (reference data) 5CSL0-06B<br />
1.5.6 Air flow and temperature distributions (reference data)<br />
Models : 2.5 kW/3.5 kW<br />
Air velocity [m/s]<br />
2.7m<br />
2m<br />
1m<br />
3.0<br />
2.0<br />
0m<br />
2.0<br />
1.0<br />
0m 1m 2m 3m 4m 5m<br />
Temperature [°C]<br />
2.7m<br />
2m<br />
1m<br />
Models : 5.0 kW<br />
18<br />
20<br />
20<br />
0m<br />
18<br />
0m 1m 2m 3m 4m 5m<br />
Air velocity [m/s]<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
2.0<br />
0.5<br />
0m 1m 2m 3m 4m 5m<br />
Temperature [°C]<br />
2.7m<br />
2m<br />
1m<br />
23<br />
19<br />
16<br />
2.5<br />
17<br />
1.0<br />
17<br />
2.0<br />
1.5<br />
18<br />
18<br />
Cooling Heating<br />
0.5<br />
0m<br />
0m 1m 2m 3m 4m 5m<br />
1.0<br />
22<br />
0.5<br />
24<br />
0.5<br />
Air velocity [m/s]<br />
Temperature [°C]<br />
2.7m<br />
130 Console<br />
2.7m<br />
2m<br />
1m<br />
2m<br />
1m<br />
33<br />
3.0<br />
33<br />
30<br />
2.0<br />
0m<br />
2.0<br />
1.0<br />
0m 1m 2m 3m 4m 5m<br />
27<br />
30<br />
0m<br />
0m 1m 2m 3m 4m 5m<br />
Cooling Heating<br />
19<br />
23<br />
Air velocity [m/s]<br />
2.7m<br />
2m<br />
1m<br />
0m<br />
0m 1m 2m 3m 4m 5m<br />
Temperature [°C]<br />
2.7m<br />
2m<br />
1m<br />
32<br />
0.5<br />
34<br />
2.5<br />
2.0<br />
1.5<br />
0.5<br />
32<br />
1.0<br />
1.0<br />
32<br />
30<br />
0m<br />
0m 1m 2m 3m 4m 5m<br />
1.0<br />
30<br />
0.5<br />
0.5<br />
0.5<br />
0.5<br />
24<br />
0.5<br />
28
5CSL0-06B<br />
1.5.7 Sound levels<br />
Overall<br />
Microphone<br />
1m<br />
1m<br />
Sound Pressure Level<br />
Octave Band Sound Pressure Level (dB re 20μPa )<br />
AQNH09GALA0[CQ09 NA0]<br />
AQNH12GALA0[CQ12 NA0]<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
High<br />
Middle<br />
Low<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Octave Band Sound Pressure Level (dB re 20μPa )<br />
AQNH18GALA0[CQ18 NA0]<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
Notes:<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound levels<br />
Console 131<br />
High<br />
Middle<br />
Low<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
Controller 5CSL0-06B<br />
1.5.8 Controller<br />
The controls will look like the following. ON/OFF BUTTON<br />
Used to turn <strong>of</strong>f/on the unit.<br />
(Optional1)<br />
(Optional2)<br />
(Optional3)<br />
Operation Mode<br />
Cooling Operation<br />
Auto Operation or Auto Changeover<br />
Healthy Dehumidification Operation<br />
Heating Operation (Only heat pump)<br />
Air Circulation<br />
Signal transmitter<br />
OPERATION MODE SELECTION BUTTON<br />
Used to select the operation mode.<br />
ROOM TEMPERATURE SETTING BUTTONS<br />
Used to select the room temperature.<br />
INDOOR FAN SPEED SELECTION BUTTON<br />
Used to select fan speed in six steps low, medium-low,<br />
medium, medium-high, high and natural wind.<br />
HORIZONTAL VANE CONTROL BUTTON<br />
Used to set the desired vertical airflow direction.<br />
VERTICAL LOUVER CONTROL BUTTON(Optional)<br />
Used to set the desired horizontal airflow direction.<br />
AUTO CLEAN BUTTON<br />
Used to set auto clean.<br />
ENERGY SAVING COOLING BUTTON<br />
Used to save Energy.<br />
ROOM TEMPERATURE CHECKING BUTTON<br />
Used to check the room temperature.<br />
TIMER BUTTON(before adjusting)<br />
Used to set the current time and the time <strong>of</strong> starting / stopping.<br />
TIME ADJUSTING BUTTONS<br />
Used to adjust the time.<br />
TIMER SET/CLEAR BUTTON(after adjusting)<br />
Used to set and to cancel the timer operation.<br />
RESET BUTTON<br />
Used prior to resetting time.<br />
PLASMA BUTTON(Optional)<br />
Used to start or stop the <strong>pl</strong>asma-purification.<br />
LED LUMINOSITY BUTTON(Optional)<br />
Used to adjust LED luminosity.<br />
132 Console
5CSL0-06B<br />
Power sup<strong>pl</strong>y<br />
2. Outdoor<br />
2.1 DC Inverter SINGLE A (1Ø, 3Ø) , High Efficiency models(1Ø)<br />
2.1.1 Power sup<strong>pl</strong>y<br />
Type Outdoor unit Capacity (kW) Circuit breaker capacity Power sup<strong>pl</strong>y<br />
1Phase<br />
Inverter<br />
External wiring procedure<br />
AUUW096D[UU09W ULD] 2.5<br />
AUUW126D[UU12W ULD] 3.5<br />
AUUW186D [UU18W UED] 5.0<br />
AUUW186D1[UU18W UED1] 5.0<br />
AUUW246D[UU24W UED] 7.1<br />
- The power sup<strong>pl</strong>y work is needed only to the outdoor unit. The power sup<strong>pl</strong>y to the indoor unit is conducted through the<br />
transmission wiring. Therefore, the power sup<strong>pl</strong>y work can be carried out at just one <strong>pl</strong>ace <strong>of</strong> the outdoor unit. It will<br />
contribute to sim<strong>pl</strong>ify the work procedure and to save cost.<br />
- Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Circuit breaker<br />
Circuit breaker<br />
Power sup<strong>pl</strong>y<br />
Earth<br />
Power sup<strong>pl</strong>y<br />
Earth<br />
Outdoor unit<br />
Outdoor unit<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 133<br />
15A<br />
20A<br />
AUUW306D[UU30W UED] 8.0 30A<br />
AUUW366D[UU36W UED] 10.0<br />
AUUW426D[UU42W U3D] 12.5<br />
AUUW486D[UU48W U3D] 14.0 40A<br />
AUUW606D[UU60W U3D] 15.0<br />
AUUW368D[UU37W UED] 10.0 20A<br />
3Phase AUUW428D[UU43W U3D] 12.5<br />
Inverter AUUW488D[UU49W U3D] 14.0 25A<br />
AUUW608D[UU61W U3D] 15.0<br />
High AUUW186DH[UU18WH UED] 5.0<br />
1Ø, 220-240V, 50Hz<br />
3Ø, 380-415V, 50Hz<br />
Efficiency AUUW216DH[UU21WH U4D] 6.0 30A 1Ø, 220-240V, 50Hz<br />
Inverter AUUW246DH[UU24WH U4D] 7.1
List <strong>of</strong> functions 5CSL0-06B<br />
2.1.2 List <strong>of</strong> functions<br />
DC Inverter Single A (1Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Convenience Auto operation(Artificial intelligence)<br />
Auto Restart Operation<br />
CAC Network Central control(LGAP)<br />
Function PDI(Power Distribution Indicator)<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Convenience Auto operation(Artificial intelligence)<br />
Auto Restart Operation<br />
CAC Network Central control(LGAP)<br />
Function PDI(Power Distribution Indicator)<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
AUUW096D<br />
[UU09W ULD]<br />
AUUW126D<br />
[UU12W ULD]<br />
AUUW186D<br />
[UU18W UED]<br />
AUUW186D1<br />
[UU18W UED1]<br />
AUUW246D<br />
[UU24W UED]<br />
ˇ O O O O O<br />
- - - - O<br />
- - - - -<br />
- - - - -<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O O O<br />
(program logic) (program logic) (program logic) (program logic) (program logic)<br />
- - - - -<br />
AUUW306D<br />
[UU30W UED]<br />
AUUW366D<br />
[UU36W<br />
UED]<br />
AUUW426D<br />
[UU42W<br />
U3D]<br />
AUUW486D<br />
[UU48W<br />
U3D]<br />
AUUW606D<br />
[UU60W<br />
U3D]<br />
O O O O O<br />
O O O O O<br />
- - - - -<br />
- - - - -<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
O O O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O O O<br />
(program logic) (program logic) (program logic) (program logic) (program logic)<br />
- - - - -<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
134 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
DC Inverter Single A (3Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Auto operation(Artificial intelligence)<br />
Convenience<br />
Auto Restart Operation<br />
Central control(LGAP)<br />
CAC Network<br />
PDI(Power Distribution Indicator)<br />
Function<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
DC Inverter High Efficiency models (1Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Convenience Auto-changeover<br />
Auto Restart Operation<br />
CAC Network Central control(LGAP)<br />
Function PDI(Power Distribution Indicator)<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
AUUW368D<br />
[UU37W UED]<br />
AUUW428D<br />
[UU43W U3D]<br />
AUUW488D<br />
[UU49W U3D]<br />
List <strong>of</strong> functions<br />
AUUW608D<br />
[UU61W U3D]<br />
O O O O<br />
O O O O<br />
O - - -<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O O<br />
(program logic) (program logic) (program logic) (program logic)<br />
- - - -<br />
AUUW186DH<br />
[UU18WH UED]<br />
AUUW216DH<br />
[UU21WH U4D]<br />
AUUW246DH<br />
[UU24WH U4D]<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O<br />
(program logic) (program logic) (program logic)<br />
- - -<br />
Notes<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate<br />
package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 135
Specifications 5CSL0-06B<br />
2.1.3 Specifications<br />
DC Inverter Single A (1Ø)<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Cassette<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Cassette<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Ceiling & floor<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Ceiling & floor<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
ATNH09GRLED<br />
[UT09 NRD]<br />
AUUW096D<br />
[UU09W ULD]<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
AUUW126D<br />
[UU12W ULD]<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
AUUW186D<br />
[UU18W UED]<br />
1.0 ~ 2.5 ~ 2.75 1.36 ~ 3.4 ~ 3.74 2.0 ~ 5.0 ~ 5.5<br />
1.2 ~ 3.0 ~ 3.3 1.60 ~ 4.0 ~ 4.4 2.2 ~ 5.5 ~ 6.05<br />
0.75 1.06 1.56<br />
0.81 1.1 1.52<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
AUUW186D1<br />
[UU18W UED1]<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
AUUW246D<br />
[UU24W UED]<br />
ATNH30GPLED<br />
[UT30 NPD]<br />
AUUW306D<br />
[UU30W UED]<br />
2.0 ~ 5.0 ~ 5.5 2.84 ~ 7.1 ~ 7.81 3.2 ~ 8.0 ~ 8.8<br />
2.2 ~ 5.5 ~ 6.05 3.2 ~ 8.0 ~ 8.8 3.6 ~ 9.0 ~ 9.9<br />
1.56 2.15 2.65<br />
1.52 2.34 2.8<br />
AVNH09GELAD<br />
[UV09 NED]<br />
AUUW096D<br />
[UU09W ULD]<br />
AVNH12GELAD<br />
[UV12 NED]<br />
AUUW126D<br />
[UU12W ULD]<br />
UVNH186BLAD<br />
[UV18 NBD]<br />
AUUW186D<br />
[UU18W UED]<br />
1.0 ~ 2.5 ~ 2.75 1.32 ~ 3.3 ~ 3.63 1.92 ~ 4.8 ~ 5.28<br />
1.2 ~ 3.0 ~ 3.3 1.52 ~ 3.8 ~ 4.18 2.04 ~ 5.1 ~ 5.61<br />
0.75 1.09 1.49<br />
0.83 1.18 1.49<br />
UVNH186BLAD<br />
[UV18 NBD]<br />
AUUW186D1<br />
[UU18W UED1]<br />
UVNH246BLAD<br />
[UV24 NBD]<br />
AUUW246D<br />
[UU24W UED]<br />
UVNH306BLAD<br />
[UV30 NBD]<br />
AUUW306D<br />
[UU30W UED]<br />
1.92 ~ 4.8 ~ 5.28 2.8 ~ 7.0 ~ 7.7 3.04 ~ 7.6 ~ 8.36<br />
2.04 ~ 5.1 ~ 5.61 3.08 ~ 7.7 ~ 8.47 3.36 ~ 8.4 ~ 9.24<br />
1.49 2.3 2.68<br />
1.49 2.74 2.99<br />
136 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Specifications<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Duct<br />
ABNH186HLAD<br />
ABNH186HLAD<br />
ABNH246HLAD<br />
ABNH306GLAD<br />
[UB18 NHD]<br />
[UB18 NHD]<br />
[UB24 NHD]<br />
[UB30 NGD]<br />
Outdoor Units<br />
AUUW186D<br />
AUUW186D1<br />
AUUW246D<br />
AUUW306D<br />
[UU18W UED]<br />
[UU18W UED1]<br />
[UU24W UED]<br />
[UU30W UED]<br />
Nominal Capacity Cooling kW 1.98 ~ 4.95 ~ 5.44 1.98 ~ 4.95 ~ 5.44 2.84 ~ 7.1 ~ 7.81 3.2 ~ 8.0 ~ 8.8<br />
(Min~Rated~Max) Heating kW 2.4 ~ 6.0 ~ 6.6 2.4 ~ 6.0 ~ 6.6 3.2 ~ 8.0 ~ 8.8 3.6 ~ 9.0 ~ 9.9<br />
Nominal Input Cooling kW<br />
1.54 1.54 2.62 2.65<br />
(Min~Rated~Max) Heating kW<br />
1.66 1.66 2.75 2.49<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Console<br />
AQNH09GALA0<br />
AQNH12GALA0<br />
AQNH18GALA0<br />
AQNH18GALA0<br />
[CQ09 NA0]<br />
[CQ12 NA0]<br />
[CQ18 NA0]<br />
[CQ18 NA0]<br />
Outdoor Units<br />
AUUW096D<br />
AUUW126D<br />
AUUW186D<br />
AUUW186D1<br />
[UU09W ULD]<br />
[UU12W ULD]<br />
[UU18W UED]<br />
[UU18W UED1]<br />
Nominal Capacity Cooling kW 1.3 ~ 2.55 ~ 3.4 1.36 ~ 3.5 ~ 3.74 2.0 ~ 4.6 ~ 5.5 2.0 ~ 4.6 ~ 5.5<br />
(Min~Rated~Max) Heating kW 1.36 ~ 3.1 ~ 4.2 1.6 ~ 4.0 ~ 4.4 2.2 ~ 5.0 ~ 6.0 2.2 ~ 5.0 ~ 6.0<br />
Nominal Input Cooling kW<br />
0.635 1.06 1.49 1.49<br />
(Min~Rated~Max) Heating kW<br />
0.74 1.08 1.46 1.46<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Cassette<br />
ATNH36GNLED ATNH42GMLED ATNH48GMLED ATNH60GMLED<br />
[UT36 NND]<br />
[UT42 NMD]<br />
[UT48 NMD]<br />
[UT60 NMD]<br />
Outdoor Units<br />
AUUW366D<br />
AUUW426D<br />
AUUW486D<br />
AUUW606D<br />
[UU36W UED] [UU42W U3D] [UU48W U3D] [UU60W U3D]<br />
Nominal Capacity Cooling kW 4.0 ~ 10.0 ~ 11.0 5.0 ~ 12.5 ~ 13.8 5.48 ~ 13.9~ 15.7 5.92 ~ 14.6 ~ 16.3<br />
(Min~Rated~Max) Heating kW 4.4 ~ 11.0 ~ 12.1 5.6 ~ 14.0 ~ 15.4 6.4 ~ 15.5 ~ 17.6 6.8 ~ 16.9 ~ 18.7<br />
Nominal Input Cooling kW<br />
3.12 3.89 4.61 5.40<br />
(Min~Rated~Max) Heating kW<br />
3.23 3.87 4.54 5.50<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Ceiling & floor<br />
UVNH366KLAD UVNH426LLAD UVNH486LLAD UVNH606LLAD<br />
[UV36 NKD]<br />
[UV42 NLD]<br />
[UV48 NLD]<br />
[UV60 NLD]<br />
Outdoor Units<br />
AUUW366D<br />
AUUW426D<br />
AUUW486D<br />
AUUW606D<br />
[UU36W UED] [UU48W U3D] [UU48W U3D] [UU60W U3D]<br />
Nominal Capacity Cooling kW 3.8 ~ 9.5 ~ 10.5 5.0 ~ 12.5 ~ 13.8 5.32 ~ 13.3 ~ 14.6 5.72 ~ 14.4 ~ 15.7<br />
(Min~Rated~Max) Heating kW 4.2 ~ 10.5 ~ 11.6 5.6 ~ 13.6 ~ 15.4 6.4 ~ 15.3 ~ 17.6 6.8 ~ 16.8 ~ 18.7<br />
Nominal Input Cooling kW<br />
3.32 4.00 4.00 5.30<br />
(Min~Rated~Max) Heating kW<br />
3.27 3.98 3.98 5.50<br />
Nominal Capacity and Nominal Input<br />
Indoor Units - Duct<br />
ABNH366GLAD ABNH426RLAD ABNH486RLAD ABNH606RLAD<br />
[UB36 NGD]<br />
[UB42 NRD]<br />
[UB48 NRD]<br />
[UB60 NRD]<br />
Outdoor Units<br />
AUUW366D<br />
AUUW486D<br />
AUUW486D<br />
AUUW606D<br />
[UU36W UED] [UU48W U3D] [UU48W U3D] [UU60W U3D]<br />
Nominal Capacity Cooling kW 4.0 ~ 9.8 ~ 11.0 5.0 ~ 12.5 ~ 13.8 5.6 ~ 14.0 ~ 15.4 5.92 ~ 14.8 ~ 16.3<br />
(Min~Rated~Max) Heating kW 4.48 ~ 11.2 ~ 12.3 5.6 ~ 14.0 ~ 15.4 6.6 ~ 16.4 ~ 18.2 6.8 ~ 16.8 ~ 18.7<br />
Nominal Input Cooling kW<br />
3.25 4.15 4.65 5.26<br />
(Min~Rated~Max) Heating kW<br />
3.28 3.73 4.54 4.57<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 137
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
A<br />
AUUW096D<br />
[UU09W ULD]<br />
AUUW126D<br />
[UU12W ULD]<br />
AUUW186D<br />
[UU18W UED]<br />
3.42/3.87 5.0/5.1 7.1/7.2<br />
- - -<br />
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50<br />
3*2.5 3*2.5 3*2.5<br />
4*0.75 4*0.75 4*0.75<br />
770*540*245 770*540*245 870*655*320<br />
32 32 46<br />
Rotary Rotary e-Scroll<br />
1 1 1<br />
5RS102XAA21 5RS102XAA21 5CS130XCC03<br />
BLDC BLDC BLDC<br />
320 320 480<br />
FV50S (PVE) FV50S (PVE) RB68A (POE)<br />
1,000 1,000 1,300<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
17 17 18<br />
2R,24C 2R,24C 2R,28C<br />
7 7 7<br />
Reversing cycle Reversing cycle Reversing cycle<br />
SIC-67FV-D843-1 SIC-67FV-D843-1 EHDS82ALG<br />
0.043 0.043 0.084<br />
- - -<br />
Propeller Propeller Propeller<br />
400 400 460<br />
Side Discharge Side Discharge Side Discharge<br />
32 32 50<br />
48/42 48/42 51/45<br />
6.35 6.35 6.35<br />
9.52 9.52 12.7<br />
15/10 15/10 40/30<br />
20 20 20<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
AUUW186D1<br />
[UU18W UED1]<br />
7.1/7.1<br />
(CST/CVT/Console)<br />
7.01/7.42<br />
(Duct)<br />
-<br />
1, 220-240, 50<br />
3*2.5<br />
4*0.75<br />
870*655*320<br />
52<br />
Rotary<br />
1<br />
GJT240DAA<br />
BLDC<br />
900<br />
FVC68D<br />
1,500<br />
R410A<br />
EEV<br />
18<br />
2R, 28C<br />
7<br />
Reversing cycle<br />
EAU52759301<br />
0.084<br />
-<br />
Propeller<br />
460<br />
Side Discharge<br />
50<br />
51/45<br />
6.35<br />
12.7<br />
40/30<br />
20(Over 5.0m)<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
138 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Specifications<br />
AUUW246D<br />
AUUW306D<br />
AUUW366D<br />
[UU24W UED]<br />
[UU30W UED]<br />
[UU36W UED]<br />
10.0/10.7 12.0/13.0 14.0/14.2<br />
- - -<br />
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50<br />
3*2.5 3*2.5 3*2.5<br />
4*0.75 4*0.75 4*0.75<br />
870*808*320 870*808*320 870*1,060*320<br />
60 60 75<br />
Rotary Rotary Rotary<br />
1 1 1<br />
5KD240XAE21 5KD240XAE21 5JD420XAD22<br />
BLDC BLDC BLDC<br />
900 900 1,300<br />
FV50S(PVE) FV50S(PVE) FV50S(PVE)<br />
2,000 2,000 2,500<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
18 18 18<br />
2R,36C 2R,36C 2R,24C X 2<br />
7 7 7<br />
Reversing cycle Reversing cycle Reversing cycle<br />
SIC-72FW-F1124-3 SIC-72FW-F1124-3 SIC-67FV-D843-1<br />
0.124 0.124 0.043 x 2<br />
- - -<br />
Propeller Propeller Propeller<br />
520 520 400<br />
Side Discharge Side Discharge Side Discharge<br />
58 58 32 X 2<br />
52/46 52/46 56/52<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
50/30 50/30 50/30<br />
35 35 50<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 139
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
AUUW426D<br />
AUUW486D<br />
AUUW606D<br />
[UU42W U3D]<br />
[UU48W U3D]<br />
[UU60W U3D]<br />
17.7/16.7 20.5/20.5 24.7/23.5<br />
- - -<br />
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50<br />
3*5.0 3*5.0 3*5.0<br />
4*0.75 4*0.75 4*0.75<br />
950*1,380*330 950*1,380*330 950*1,380*330<br />
103 103 103<br />
Rotary Rotary Rotary<br />
1 1 1<br />
5JD420XAD22 5JD420XAD22 5JD420XAD22<br />
BLDC BLDC BLDC<br />
1,300 1,300 1,300<br />
FV50S(PVE) FV50S(PVE) FV50S(PVE)<br />
3,600 3,600 3,600<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
17 17 17<br />
2R,32C x 2 2R,32C x 2 2R,32C x 2<br />
7 7 7<br />
Reversing cycle Reversing cycle Reversing cycle<br />
SIC-72FW-F1124-3 SIC-72FW-F1124-3 SIC-72FW-F1124-3<br />
0.124 X 2 0.124 X 2 0.124 X 2<br />
- - -<br />
Propeller Propeller Propeller<br />
526 526 526<br />
Side Discharge Side Discharge Side Discharge<br />
55 X 2 55 X 2 55(1,942) X 2<br />
55/51 55/51 55/51<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
75/30 75/30 75/30<br />
40 40 40<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
140 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
DC Inverter Single A (3Ø)<br />
Specifications<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
ATNH36GNLED ATNH42GMLED ATNH48GMLED ATNH60GMLED<br />
[UT36 NND]<br />
[UT42 NMD]<br />
[UT48 NMD]<br />
[UT60 NMD]<br />
Outdoor Units<br />
AUUW368D<br />
AUUW428D<br />
AUUW488D<br />
AUUW608D<br />
[UU37W UED] [UU43W U3D] [UU49W U3D] [UU61W U3D]<br />
Nominal Capacity Cooling kW 4.0 ~ 10.0 ~ 11.0 5.0 ~ 12.5 ~ 13.8 5.48 ~ 13.8~ 15.7 5.92 ~ 14.7 ~ 16.3<br />
(Min~Rated~Max) Heating kW 4.4 ~ 11.0 ~ 12.1 5.6 ~ 14.0 ~ 15.4 6.4 ~ 15.9 ~ 17.6 6.8 ~ 17.0 ~ 18.7<br />
Nominal Input Cooling kW<br />
3.12 3.89 4.58 5.63<br />
(Min~Rated~Max) Heating kW<br />
3.23 3.87 4.66 5.64<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
UVNH366KLAD UVNH426LLAD UVNH486LLAD UVNH606LLAD<br />
[UV36 NKD]<br />
[UV42 NLD]<br />
[UV48 NLD]<br />
[UV60 NLD]<br />
Outdoor Units<br />
AUUW368D<br />
AUUW428D<br />
AUUW488D<br />
AUUW608D<br />
[UU37W UED] [UU43W U3D] [UU49W U3D] [UU61W U3D]<br />
Nominal Capacity Cooling kW 3.8 ~ 9.5 ~ 10.5 5.0 ~ 12.5 ~ 13.8 5.32 ~ 13.3 ~ 14.6 5.72 ~ 14.4 ~ 15.7<br />
(Min~Rated~Max) Heating kW 4.2 ~ 10.5 ~ 11.6 5.6 ~ 13.6 ~ 15.4 6.4 ~ 15.3 ~ 17.6 6.8 ~ 16.8~ 18.7<br />
Nominal Input Cooling kW<br />
3.32 4.00 4.41 5.30<br />
(Min~Rated~Max) Heating kW<br />
3.27 3.98 4.76 5.50<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
ABNH366GLAD ABNH426RLAD ABNH486RLAD ABNH606RLAD<br />
[UB36 NGD]<br />
[UB42 NRD]<br />
[UB48 NRD]<br />
[UB60 NRD]<br />
Outdoor Units<br />
AUUW368D<br />
AUUW428D<br />
AUUW488D<br />
AUUW608D<br />
[UU37W UED] [UU43W U3D] [UU49W U3D] [UU61W U3D]<br />
Nominal Capacity Cooling kW 4.0 ~ 10.0 ~ 11.0 5.0 ~ 12.5 ~ 13.8 5.6 ~ 14.0 ~ 15.4 5.92 ~ 14.8 ~ 16.3<br />
(Min~Rated~Max) Heating kW 4.48 ~ 11.2 ~ 12.3 5.6 ~ 14.0 ~ 15.4 6.6 ~ 16.7 ~ 18.2 6.8 ~ 17.0 ~ 18.7<br />
Nominal Input Cooling kW<br />
3.51 4.15 4.65 5.26<br />
(Min~Rated~Max) Heating kW<br />
3.49 3.82 4.57 4.70<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 141
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
AUUW368D<br />
AUUW428D<br />
AUUW488D<br />
[UU37W UED]<br />
[UU43W U3D]<br />
[UU49W U3D]<br />
3.7/3.9 4.09/4.28 4.98/5.23<br />
- - -<br />
3 ,380-415 , 50 3 ,380-415 , 50 3 ,380-415 , 50<br />
5 x 2.5 5 x 2.5 5 x 2.5<br />
4*0.75 4*0.75 4*0.75<br />
870*1,060*320 950*1,380*330 950*1,380*330<br />
80 103 103<br />
Rotary Rotary Rotary<br />
1 1 1<br />
5KD240XBA21 5JD420XBB22 5JD420XBB22<br />
BLDC BLDC BLDC<br />
900 1,300 1,300<br />
FV50S (PVE) FV50S (PVE) FV50S (PVE)<br />
2,650 3,600 3,600(127)<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
18 17 17<br />
2R,24C 2R,32C 2R,32C<br />
7 7 7<br />
Reversing cycle Reversing cycle Reversing cycle<br />
SIC - 67FV-D843-1 SIC - 72FW- 8F1124-3 SIC - 72FW- 8F1124-3<br />
0.043*2 0.124*2 0.124*2<br />
- - -<br />
Propeller Propeller Propeller<br />
2/400 2/526 2/526<br />
Side Discharge Side Discharge Side Discharge<br />
32*2 55*2 55*2<br />
54/50 55/51 55/51<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
50/30 75/30 75/30<br />
45 40 40<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
142 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
AUUW608D<br />
[UU61W U3D]<br />
5.91/5.79<br />
-<br />
3 ,380-415 , 50<br />
5 x 2.5<br />
4*0.75<br />
950*1,380*330<br />
103<br />
Rotary<br />
1<br />
5JD420XBB22<br />
BLDC<br />
1,300<br />
FV50S (PVE)<br />
3,600(127)<br />
R410A<br />
EEV<br />
17<br />
2R,32C<br />
7<br />
Reversing cycle<br />
SIC - 72FW- 8F1124-3<br />
0.124*2<br />
-<br />
Propeller<br />
2/526<br />
Side Discharge<br />
55*2<br />
55/51<br />
9.52<br />
15.88<br />
75/30<br />
40<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Specifications<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 143
Specifications 5CSL0-06B<br />
DC Inverter High Efficiency models (1Ø)<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
AUUW186DH<br />
[UU18WH UED]<br />
ATNH21GNLED<br />
[UT21 NND]<br />
AUUW216DH<br />
[UU21WH U4D]<br />
ATNH24GPLED<br />
[UT24 NPD]<br />
AUUW246DH<br />
[UU24WH U4D]<br />
2.0 ~ 5.0 ~ 5.5 2.8 ~ 6.0 ~ 8.0 2.8 ~ 7.0 ~ 8.4<br />
2.2 ~ 5.5 ~ 6.05 3.2 ~ 7.0 ~ 9.0 3.2 ~ 8.0 ~ 9.4<br />
1.35 1.56 1.92<br />
1.35 1.66 1.93<br />
144 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, v, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Quantity<br />
Model<br />
Motor Type<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge(at 7.5m) g<br />
Type<br />
Control<br />
Heat exchanger Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Tube Size (OD) mm<br />
Defrosting Method<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Type<br />
Fan No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level (H/L) Sound Press,1m dB(A)+3<br />
Piping connections Liquid mm<br />
Gas mm<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Specifications<br />
AUUW186DH<br />
AUUW216DH<br />
AUUW246DH<br />
[UU18WH UED] [UU21WH U4D] [UU24WH U4D]<br />
5.0/5.5 6.9/7.4 8.5/8.6<br />
- - -<br />
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50<br />
3*2.5 3*2.5 3*2.5<br />
4*0.75 4*0.75 4*0.75<br />
870*808*320 950*834*330 950*834*330<br />
52 52 52<br />
Rotary Rotary Rotary<br />
1 1 1<br />
5KD240XAE21 5KD240XAE21 5KD240XAE21<br />
BLDC BLDC BLDC<br />
900 900 900<br />
FV50S(PVE) FV50S(PVE) FV50S(PVE)<br />
1,500 1,500 1,500<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
18 17 17<br />
2R,36C 2R,38C 2R,38C<br />
7 7 7<br />
Reversing cycle Reversing cycle Reversing cycle<br />
SIC-72FW-F1124 SIC-72FW-F1124 SIC-72FW-F1124<br />
0.124 0.124 0.124<br />
- - -<br />
BLDC BLDC BLDC<br />
528 528 528<br />
Side Side Side<br />
50 58 58<br />
52/46 55/49 55/49<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
40/30 50/30 50/30<br />
20 40 40<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 145
Dimensions<br />
2.1.4 Dimensions<br />
OUTDOOR UNIT<br />
AUUW096D[UU09W ULD]<br />
AUUW126D[UU12W ULD]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
6<br />
Earth screw<br />
SVC valve cover<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
Technical Specification<br />
AUUW126D[UU12W ULD]<br />
1/ 220-240 / 50<br />
AUUW096D[UU09W ULD]<br />
1/ 220-240 / 50<br />
Model name<br />
Simultaneous operation<br />
Refer to combination table<br />
Refer to combination table<br />
6.35<br />
9.52<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
146 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
6.35<br />
9.52<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Note<br />
CHASSIS CODE: UL<br />
OUTDOOR UNIT<br />
76, Seongsan-dong, Changwon City, Gyeongnam,<br />
641-713, Korea<br />
www.lge.com/airconditioner
5CSL0-06B Dimensions<br />
OUTDOOR UNIT<br />
AUUW186D [UU18W UED]<br />
AUUW186D1[UU18W UED1]<br />
Part Name Remark<br />
870<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
160<br />
546<br />
6<br />
340<br />
360<br />
Earth screw<br />
SVC valve cover<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
10<br />
54.6<br />
Technical Specification<br />
AUUW186D1[UU18W UED1]<br />
1/ 220-240 / 50<br />
AUUW186D[UU18W UED]<br />
1/ 220-240 / 50<br />
Model name<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Simultaneous operation Refer to combination table<br />
301<br />
Heating Capacity<br />
320<br />
6.35<br />
12.7<br />
6.35<br />
12.7<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 147<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Ø531<br />
4<br />
Note<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
1<br />
513<br />
630<br />
655<br />
2<br />
319<br />
3<br />
5<br />
50<br />
80<br />
25<br />
CHASSIS CODE: UE<br />
OUTDOOR UNIT<br />
76, Seongsan-dong, Changwon City, Gyeongnam,<br />
641-713, Korea<br />
www.lge.com/airconditioner
Dimensions<br />
AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
6<br />
Earth screw<br />
SVC valve cover<br />
AUUW246D[UU24W UED] AUUW306D[UU30W UED]<br />
1/ 220-240 / 50<br />
1/ 220-240 / 50<br />
Simultaneous operation<br />
Refer to combination table<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
148 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
9.52<br />
15.88<br />
9.52<br />
15.88<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Note<br />
1<br />
OUTDOOR UNIT
5CSL0-06B Dimensions<br />
AUUW366D[UU36W UED]<br />
AUUW368D[UU37W UED]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
6<br />
Earth screw<br />
SVC valve cover<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
AUUW366D[UU36W UED] AUUW368D[UU37W UED]<br />
1/ 220-240 / 50<br />
3/ 380-415 / 50<br />
Simultaneous operation<br />
_Refer<br />
to combination table<br />
9.52<br />
9.52<br />
15.88<br />
15.88<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 149<br />
Note<br />
OUTDOOR UNIT
Dimensions<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
4<br />
Supporter<br />
AUUW606D[UU60W U3D]<br />
1/ 220-240 / 50<br />
AUUW486D[UU48W U3D]<br />
AUUW426D[UU42W U3D]<br />
Model name<br />
1/ 220-240 / 50<br />
1/ 220-240 / 50<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
9.52<br />
15.88<br />
Simultaneous operation<br />
Refer to combination table<br />
9.52<br />
15.88<br />
Heating Capacity<br />
9.52<br />
15.88<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
150 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Note<br />
490<br />
OUTDOOR UNIT
5CSL0-06B Dimensions<br />
OUTDOOR UNIT<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
Technical Specification<br />
Model name<br />
4<br />
Supporter<br />
AUUW608D[UU61W U3D]<br />
3/ 380-415 / 50<br />
AUUW488D[UU49W U3D]<br />
3/ 380-415 / 50<br />
AUUW428D[UU43W U3D]<br />
3/ 380-415 / 50<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Simultaneous operation<br />
Refer to combination table<br />
Heating Capacity<br />
9.52<br />
15.88<br />
9.52<br />
15.88<br />
9.52<br />
15.88<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Note<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 151<br />
490<br />
CHASSIS CODE: U3<br />
OUTDOOR UNIT<br />
76, Seongsan-dong, Changwon City, Gyeongnam,<br />
641-713, Korea<br />
www.lge.com/airconditioner
Dimensions<br />
OUTDOOR UNIT<br />
AUUW186DH[UU18WH UED]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
6<br />
Earth screw<br />
SVC valve cover<br />
Technical Specification<br />
AUUW186DH[UU18WH UED]<br />
1/ 220-240 / 50<br />
Simultaneous 4.04 operation<br />
Refer to combination 13,800 table<br />
9.52<br />
15.88<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
152 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Note<br />
1<br />
CHASSIS CODE: UE1<br />
76, Seongsan-dong, Changwon City, Gyeongnam,<br />
641-713, Korea<br />
www.lge.com/airconditioner
5CSL0-06B Dimensions<br />
OUTDOOR UNIT<br />
AUUW216DH [UU21WH U4D]<br />
AUUW246DH [UU24WH U4D]<br />
Remark<br />
Part Name<br />
Air discharge grille<br />
Item No.<br />
1<br />
Gas pipe connection<br />
2<br />
Liquid pipe connection<br />
Power & transmission connection<br />
3<br />
4<br />
Earth screw<br />
5<br />
Technical Specification<br />
AUUW216DH [UU21WH U4D] AUUW246DH [UU24WH U4D]<br />
1/ 220-240 / 50<br />
1/ 220-240 / 50<br />
Simultaneous operation<br />
Refer to combination table<br />
9.52<br />
9.52<br />
15.88<br />
15.88<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 153<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Note<br />
CHASSIS CODE: U4<br />
76, Seongsan-dong, Changwon City, Gyeongnam,<br />
641-713, Korea<br />
www.lge.com/airconditioner
Piping diagrams<br />
2.1.5 Piping diagrams<br />
Models : AUUW096D[UU09W ULD], AUUW126D[UU12W ULD]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 9.52mm)<br />
Liquid<br />
(Ø 6.35mm)<br />
EEV<br />
Accumulator<br />
5CSL0-06B<br />
154 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
Th4<br />
Th3<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2
5CSL0-06B Piping diagrams<br />
Models : AUUW186D[UU18W UED]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 9.52mm)<br />
Liquid<br />
(Ø 6.35mm)<br />
EEV<br />
Accumulator<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 155<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
OUTDOOR UNIT<br />
Th4<br />
Th3<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2
Piping diagrams 5CSL0-06B<br />
Models : AUUW186D1[UU18W UED1]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 12.7mm)<br />
Liquid<br />
(Ø 6.35mm)<br />
E.E.V.<br />
Accumulator<br />
r<br />
156 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
OUTDOOR UNIT<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2<br />
Th5 Thermistor for condenser middle pipe temperature CN_TH4<br />
Th4<br />
Heat<br />
Exchanger<br />
Th5<br />
Th3
5CSL0-06B<br />
Models : AUUW246D[UU24W UED], AUUW306D[UU30W UED]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
EEV<br />
Accumulator<br />
r<br />
Piping diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 157<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
Th4<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2<br />
Th3
Piping diagrams 5CSL0-06B<br />
Models : AUUW366D[UU36W UED], AUUW426D[UU42W U3D], AUUW486D[UU48W U3D], AUUW606D[UU60W U3D],<br />
AUUW428D[UU43W U3D], AUUW488D[UU49W U3D], AUUW608D[UU61W U3D]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
EEV<br />
Accumulator<br />
r<br />
Th1<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2<br />
158 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Th2<br />
Th3<br />
Th4
5CSL0-06B<br />
Models : AUUW368D[UU37W UED]<br />
Field piping<br />
Gas Ø15.88mm<br />
Field piping<br />
Liquid Ø9.52mm<br />
Accumulator<br />
Low Pressure<br />
Switch<br />
Solenoid<br />
valve<br />
Th1<br />
Inverter<br />
Compressor<br />
Reversing<br />
Valve<br />
Oil<br />
Separator<br />
Piping diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 159<br />
Th2<br />
High Pressure Switch<br />
EEV<br />
.<br />
Th3<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_EEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH3<br />
Th2 Thermistor for discharge pipe temperature CN_TH3<br />
Th3 Thermistor for condenser pipe temperature CN_TH2<br />
Th4 Thermistor for outdoor air temperature CN_TH2<br />
Th4
Piping diagrams 5CSL0-06B<br />
Models: AUUW186DH[UU18WH UED], , AUUW216DH [UU21WH U4D], AUUW246DH [UU24WH U4D]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
E.E.V.<br />
Accumulator<br />
r<br />
160 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN-EEV<br />
Th1 Thermistor for suction pipe temperature CN-TH3<br />
Th2 Thermistor for discharge pipe temperature CN-TH3<br />
Th3 Thermistor for condenser pipe temperature CN-TH2<br />
Th4 Thermistor for outdoor air temperature CN-TH2<br />
Th5 Thermistor for condenser middle pipe temperature CN-TH4<br />
Th4<br />
Heat<br />
Exchanger<br />
Th5<br />
Th3
5CSL0-06B<br />
2.1.6 Wiring diagrams<br />
Models : AUUW096D[UU09W ULD], AUUW126D[UU12W ULD]<br />
Notes:<br />
BL<br />
RD<br />
YL<br />
PSCM<br />
Phase current<br />
detector<br />
IPM<br />
BLUE<br />
RED<br />
YELLOW<br />
BK<br />
OR<br />
GN/YL<br />
SMPS<br />
CN_MOTOR<br />
BLACK<br />
ORANGE<br />
GREEN/YELLOW<br />
4WAY<br />
DC LINK<br />
VOLTAGE<br />
ERROR<br />
DISPLAY<br />
CN_EEV<br />
EEPROM<br />
Wiring diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 161<br />
BR<br />
WH<br />
CURRENT<br />
DETECTOR<br />
CN_CENTRAL<br />
BROWN<br />
WHITE<br />
FIELD WIRING<br />
EMC<br />
CN_TH1(PIPE/AIR)<br />
CN_TH1(DIS/SUC)<br />
CN_FLASH(WRITER)<br />
CN_LGMV
Wiring diagrams 5CSL0-06B<br />
Models : AUUW186D[UU18W UED]<br />
Notes:<br />
BL<br />
RD<br />
YL<br />
PSCM<br />
Phase current<br />
detector<br />
BLUE<br />
RED<br />
YELLOW<br />
IPM<br />
PSC OUT<br />
DC LINK<br />
VOLTAGE<br />
SMPS<br />
BK<br />
OR<br />
GN/YL<br />
CN_MOTOR<br />
DIP SW<br />
BLACK<br />
ORANGE<br />
GREEN/YELLOW<br />
4WAY<br />
EEPROM<br />
ERROR<br />
DISPLAY<br />
CN_CENTRAL<br />
CN_EEV<br />
CURRENT<br />
DETECTOR<br />
CN_COM<br />
162 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
BR<br />
WH<br />
BROWN<br />
WHITE<br />
FIELD WIRING<br />
EMC<br />
CN_TH1(SUC/DIS)<br />
COMMUNICATION<br />
PART<br />
CN_TH2(AIR/PIPE)<br />
CN_FLASH(WRITER)<br />
CN_LGMV
5CSL0-06B<br />
Models : AUUW186D1[UU18W UED1]<br />
CN-PFC-OUT<br />
CN-MOTOR1<br />
CN-PFC-IN CN_4WAY<br />
CN_EEV1<br />
CN_CENTRAL CN_COM<br />
CN_TH3<br />
CN_TH2<br />
CN_TH4<br />
CN_FLASH<br />
CN_LGMV<br />
CN_CP(N)<br />
CN_CP(L)<br />
Wiring diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 163
Wiring diagrams 5CSL0-06B<br />
Models : AUUW246D[UU24W UED], AUUW306D [UU30W UED], AUUW186DH [UU18WH UED]<br />
CN-PFC-OUT<br />
DC LINK VOLTAGE<br />
PFC MODULE<br />
PHASE CURRENT<br />
DETECTOR<br />
IPM<br />
CN-PFC-IN<br />
SMPS<br />
CN-MOTOR1<br />
ERROR<br />
DISPLAY CURRENT<br />
CN 4WAY CN_H/P DETECTOR EMC<br />
DIP SW<br />
CN_LEV1<br />
CN_CENTRAL<br />
CN_COM<br />
CN_TH3<br />
CN_TH2<br />
CN_FLASH(WRITER)<br />
CN_LGMV<br />
COMMUNICATION PART<br />
164 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW366D[UU36W UED]<br />
DC LINK VOLTAGE<br />
PFC MODULE<br />
PHASE CURRENT<br />
DETECTOR<br />
CN-PFC-OUT<br />
IPM<br />
CN-PFC-IN<br />
ERROR<br />
DISPLAY CURRENT<br />
CN 4WAY CN_H/P DETECTOR EMC<br />
CN-MOTOR1 DIP SW CN_LEV1<br />
SMPS<br />
CN-MOTOR2<br />
EEPROM<br />
CN_COM<br />
CN_TH3<br />
CN_TH2<br />
Wiring diagrams<br />
CN_FLASH(WRITER)<br />
CN_LGMV<br />
COMMUNICATION PART<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 165
Wiring diagrams 5CSL0-06B<br />
Models : AUUW426D[UU42W U3D], AUUW486D[UU48W U3D], AUUW606D[UU60W U3D]<br />
CN-<br />
4WAY<br />
CN-H/PRESS<br />
CENTRAL<br />
CONTROLLER<br />
POWER SUPPLY<br />
MAIN PCB ASSY<br />
CN-POWER<br />
CN-COMM<br />
CN-EEV1<br />
CN-COM(INV)<br />
CN-JIG_PC<br />
CN-CENTRAL<br />
CN-TH1<br />
CN-TH2<br />
CN-WRITER<br />
CN-FLASH<br />
CN-<br />
MAIN(COM)<br />
CN-<br />
MOTOR2<br />
CN-<br />
MOTOR1<br />
INVERTER PCB ASSY<br />
CN_ POWER<br />
CN(N) CN(L)<br />
166 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW368D [UU37W UED]<br />
CN_14-2(IU+)<br />
CN_14-4(IV+)<br />
CN_14-3(IV-)<br />
CN_IPM<br />
CN_GATE2<br />
CN_GATE1<br />
CN_14-1(IU-)<br />
TAB1<br />
CN_TH2<br />
CN_TH3<br />
CN_IPM(N)<br />
CN_LEV1<br />
CN_PRESS<br />
CN_IPM(P) CN_COIL(IN)<br />
CN_OIL/S<br />
CN_T<br />
CN_S<br />
CN_R<br />
CN_FAN(A)<br />
CN_POWER<br />
CN_FAN(B)<br />
CN_N<br />
Wiring diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 167<br />
CN_PWR<br />
CN_INV/HT<br />
CN_4WAY<br />
CN_PHASE<br />
CN_COM
Wiring diagrams 5CSL0-06B<br />
Models : AUUW428D[UU43W U3D], AUUW488D[UU49W U3D], AUUW608D[UU61W U3D]<br />
CN-<br />
C/FAN<br />
CN-<br />
4WAY<br />
CENTRAL<br />
CONTROLLER<br />
POWER SUPPLY<br />
CN-H/PRESS<br />
MAIN PCB ASSY<br />
CN-POWER<br />
CN-COMM<br />
CN-EEV1<br />
CN-COM(INV)<br />
CN-JIG_PC<br />
CN-CENTRAL<br />
CN-TH1<br />
CN-TH2<br />
CN-WRITER<br />
CN-FLASH<br />
CN_COMP<br />
CN_<br />
COM(INV)<br />
CN-MOTOR1<br />
CN-MOTOR2<br />
INVERTER PCB ASSY<br />
CN-L2(S)<br />
CN-L1(R)<br />
CN_<br />
AC220V<br />
168 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
to inverter<br />
driver<br />
R2<br />
S2<br />
T-N<br />
T2<br />
Noise filter PCB<br />
To Ceramic resistor<br />
Phase detector_main<br />
Wiring diagrams<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 169<br />
R1<br />
S1<br />
T1<br />
N1<br />
From main power
Wiring diagrams 5CSL0-06B<br />
Models: AUUW216DH [UU21WH U4D], AUUW246DH [UU24WH U4D]<br />
CN-PFC-OUT<br />
CN-MOTOR1<br />
MAIN PCB ASSY<br />
CN-PFC-IN CN 4WAY CN_PRESS<br />
CN_EEV<br />
CN_CENTRAL CN_COM<br />
CN_TH3<br />
CN_TH2<br />
CN_TH4<br />
CN_FLASH<br />
CN_LGMVC<br />
CN_CP(N)<br />
CN_CP(L)<br />
170 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
2.1.7 Capacity tables<br />
Models : AUUW096D + ATNH09GRLED, AVNH09GELAD, AQNH09GALA0<br />
[UU09W ULD] + [UT09 NRD], [UV09 NED], [CQ09 NAD]<br />
• Cooling Capacity<br />
Model ATNH09GRLED[UT09 NRD]<br />
AFR 8.5<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 2.70 2.46 0.55 2.58 2.38 0.57 2.42 2.28 0.77 2.35 2.21 0.86 2.24 2.14 0.94 2.18 2.07 0.92<br />
16.0 22.0 2.86 2.49 0.74 2.74 2.42 0.75 2.59 2.33 0.90 2.51 2.25 0.97 2.41 2.19 1.01 2.35 2.12 0.96<br />
18.0 25.0 3.03 2.51 0.80 2.91 2.44 0.81 2.75 2.36 0.95 2.67 2.29 0.99 2.57 2.23 1.03 2.51 2.16 0.96<br />
19.0 27.0 3.11 2.54 0.81 2.99 2.47 0.82 2.83 2.39 0.96 2.75 2.31 0.99 2.65 2.26 1.03 2.59 2.19 0.96<br />
22.0 30.0 3.36 2.59 0.81 3.24 2.52 0.83 3.08 2.45 0.98 3.00 2.38 1.04 2.90 2.33 1.05 2.84 2.26 0.97<br />
24.0 32.0 3.53 2.64 0.81 3.41 2.57 0.84 3.24 2.51 1.00 3.17 2.44 1.06 3.06 2.39 1.07 3.00 2.32 0.99<br />
Model AVNH09GELAD[UV09 NED]<br />
AFR 7.6<br />
Indoor Air<br />
Temperature<br />
Model AQNH09GALA0[CQ09 NAD]<br />
AFR 8.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 2.70 2.55 0.55 2.58 2.47 0.57 2.42 2.37 0.77 2.35 2.29 0.86 2.24 2.22 0.94 2.18 2.14 0.92<br />
16.0 22.0 2.86 2.58 0.74 2.74 2.50 0.75 2.59 2.41 0.90 2.51 2.33 0.97 2.41 2.27 1.01 2.35 2.19 0.96<br />
18.0 25.0 3.03 2.60 0.80 2.91 2.53 0.81 2.75 2.45 0.95 2.67 2.37 0.99 2.57 2.31 1.03 2.51 2.24 0.96<br />
19.0 27.0 3.11 2.63 0.81 2.99 2.56 0.82 2.83 2.47 0.96 2.75 2.39 0.99 2.65 2.34 1.03 2.59 2.27 0.96<br />
22.0 30.0 3.36 2.68 0.81 3.24 2.61 0.83 3.08 2.54 0.98 3.00 2.47 1.04 2.90 2.42 1.05 2.84 2.35 0.97<br />
24.0 32.0 3.53 2.73 0.81 3.41 2.67 0.84 3.24 2.60 1.00 3.17 2.52 1.06 3.06 2.48 1.07 3.00 2.41 0.99<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
2.12 2.00 0.83<br />
2.28 2.06 0.84<br />
2.45 2.10 0.82<br />
2.53 2.13 0.81<br />
2.78 2.21 0.81<br />
2.94 2.27 0.83<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
2.12 2.07 0.83<br />
2.28 2.13 0.84<br />
2.45 2.18 0.82<br />
2.53 2.21 0.81<br />
2.78 2.29 0.81<br />
2.94 2.35 0.83<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 3.33 3.08 0.53 3.19 2.98 0.55 2.99 2.86 0.74 2.90 2.76 0.83 2.78 2.68 0.91 2.70 2.58 0.89<br />
16.0 22.0 3.54 3.12 0.72 3.39 3.02 0.73 3.20 2.91 0.88 3.10 2.82 0.94 2.98 2.74 0.98 2.90 2.65 0.93<br />
18.0 25.0 3.74 3.15 0.78 3.60 3.06 0.78 3.40 2.95 0.92 3.31 2.86 0.96 3.18 2.79 1.00 3.10 2.70 0.93<br />
19.0 27.0 3.85 3.17 0.79 3.70 3.09 0.79 3.50 2.99 0.93 3.40 2.89 0.96 3.28 2.83 1.00 3.20 2.74 0.93<br />
22.0 30.0 4.15 3.24 0.79 4.01 3.16 0.81 3.81 3.07 0.95 3.71 2.98 1.01 3.58 2.92 1.01 3.51 2.83 0.94<br />
24.0 32.0 4.36 3.30 0.78 4.21 3.22 0.81 4.01 3.14 0.97 3.91 3.05 1.03 3.79 2.99 1.04 3.71 2.91 0.96<br />
TC SHC PI<br />
2.62 2.50 0.80<br />
2.83 2.57 0.81<br />
3.03 2.63 0.79<br />
3.13 2.67 0.78<br />
3.43 2.76 0.78<br />
3.63 2.84 0.80<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 171
Capacity tables 5CSL0-06B<br />
Models : AUUW096D + ATNH09GRLED, AVNH09GELAD, AQNH09GALA0<br />
[UU09W ULD] + [UT09 NRD], [UV09 NED], [CQ09 NAD]<br />
• Heating Capacity<br />
Model ATNH09GRLED[UT09 NRD]<br />
AFR 8.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 2.35 1.30 2.51 1.32 2.80 1.26 3.08 1.17 3.36 1.11 3.57 1.08 3.67 1.03<br />
18 2.33 1.32 2.50 1.36 2.81 1.29 3.08 1.21 3.33 1.14 3.53 1.10 3.66 1.04<br />
20 2.31 1.34 2.50 1.39 2.81 1.33 3.07 1.24 3.30 1.16 3.50 1.12 3.66 1.04<br />
21 2.30 1.36 2.50 1.41 2.81 1.35 3.06 1.26 3.28 1.17 3.50 1.13 3.64 1.04<br />
22 2.30 1.37 2.50 1.43 2.81 1.37 3.05 1.27 3.26 1.18 3.50 1.13 3.61 1.04<br />
24 2.28 1.39 2.48 1.45 2.77 1.39 3.04 1.28 3.25 1.19 3.44 1.13 3.59 1.05<br />
Model AVNH09GELAD[UV09 NED]<br />
AFR 7.6<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 2.35 1.33 2.51 1.36 2.80 1.29 3.08 1.20 3.36 1.13 3.57 1.11 3.67 1.05<br />
18 2.33 1.35 2.50 1.39 2.81 1.33 3.08 1.24 3.33 1.16 3.53 1.13 3.66 1.06<br />
20 2.31 1.38 2.50 1.42 2.81 1.36 3.07 1.27 3.30 1.19 3.50 1.15 3.66 1.07<br />
21 2.30 1.39 2.50 1.45 2.81 1.38 3.06 1.29 3.28 1.20 3.50 1.15 3.64 1.07<br />
22 2.30 1.40 2.50 1.47 2.81 1.40 3.05 1.30 3.26 1.21 3.50 1.16 3.61 1.07<br />
24 2.28 1.43 2.48 1.49 2.77 1.42 3.04 1.32 3.25 1.22 3.44 1.16 3.59 1.08<br />
Model AQNH09GALA0[CQ09 NAD]<br />
AFR 8.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 2.99 1.33 3.19 1.35 3.56 1.29 3.92 1.20 4.27 1.13 4.55 1.10 4.67 1.05<br />
18 2.96 1.35 3.19 1.39 3.57 1.32 3.92 1.23 4.24 1.16 4.49 1.13 4.65 1.06<br />
20 2.94 1.37 3.19 1.42 3.57 1.36 3.91 1.27 4.20 1.18 4.46 1.14 4.66 1.07<br />
21 2.93 1.39 3.19 1.44 3.57 1.38 3.90 1.28 4.17 1.20 4.46 1.15 4.63 1.07<br />
22 2.93 1.40 3.19 1.46 3.57 1.40 3.89 1.30 4.14 1.20 4.46 1.16 4.59 1.07<br />
24 2.90 1.43 3.15 1.48 3.53 1.42 3.86 1.31 4.14 1.21 4.38 1.16 4.57 1.07<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
172 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW126D + ATNH12GRLED, AVNH12GELAD, AQNH12GALA0<br />
[UU12W ULD] + [UT12 NRD], [UV12 NED], [CQ12 NAD]<br />
• Cooling Capacity<br />
Model ATNH12GRLED[UT12 NRD]<br />
AFR 9.5<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 3.67 3.39 0.77 3.51 3.28 0.81 3.29 3.14 1.08 3.19 3.04 1.21 3.05 2.95 1.33 2.97 2.84 1.30<br />
16.0 22.0 3.89 3.43 1.05 3.73 3.33 1.06 3.52 3.20 1.28 3.42 3.10 1.37 3.28 3.02 1.43 3.19 2.92 1.36<br />
18.0 25.0 4.12 3.46 1.13 3.96 3.36 1.14 3.74 3.25 1.34 3.64 3.15 1.40 3.50 3.07 1.45 3.41 2.97 1.36<br />
19.0 27.0 4.23 3.49 1.15 4.07 3.40 1.16 3.85 3.29 1.36 3.74 3.18 1.40 3.61 3.11 1.46 3.53 3.01 1.36<br />
22.0 30.0 4.57 3.56 1.15 4.41 3.47 1.18 4.19 3.37 1.39 4.08 3.28 1.47 3.94 3.21 1.48 3.86 3.12 1.37<br />
24.0 32.0 4.80 3.63 1.14 4.63 3.54 1.19 4.41 3.45 1.41 4.31 3.35 1.50 4.17 3.29 1.51 4.08 3.20 1.40<br />
Model AVNH12GELAD[UV12 NED]<br />
AFR 9.2<br />
Indoor Air<br />
Temperature<br />
Model AQNH12GALA0[CQ12 NAD]<br />
AFR 9.0<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 3.56 3.40 0.79 3.40 3.29 0.83 3.20 3.16 1.11 3.10 3.05 1.24 2.96 2.96 1.37 2.88 2.85 1.34<br />
16.0 22.0 3.78 3.44 1.08 3.62 3.34 1.09 3.41 3.22 1.31 3.32 3.11 1.41 3.18 3.03 1.47 3.10 2.93 1.40<br />
18.0 25.0 4.00 3.47 1.16 3.84 3.37 1.17 3.63 3.26 1.38 3.53 3.16 1.44 3.40 3.08 1.49 3.31 2.98 1.40<br />
19.0 27.0 4.11 3.50 1.18 3.95 3.41 1.19 3.74 3.30 1.40 3.63 3.19 1.44 3.50 3.12 1.50 3.42 3.02 1.40<br />
22.0 30.0 4.44 3.57 1.18 4.28 3.48 1.21 4.06 3.38 1.43 3.96 3.29 1.51 3.83 3.22 1.52 3.75 3.13 1.41<br />
24.0 32.0 4.65 3.64 1.17 4.49 3.55 1.22 4.28 3.46 1.45 4.18 3.37 1.54 4.04 3.30 1.55 3.96 3.21 1.44<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
2.89 2.75 1.17<br />
3.11 2.83 1.18<br />
3.33 2.89 1.15<br />
3.44 2.93 1.14<br />
3.77 3.04 1.14<br />
4.00 3.12 1.17<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
2.80 2.76 1.20<br />
3.02 2.84 1.22<br />
3.23 2.90 1.19<br />
3.34 2.94 1.18<br />
3.66 3.05 1.18<br />
3.88 3.14 1.20<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 3.67 3.47 0.79 3.51 3.36 0.83 3.29 3.22 1.11 3.19 3.11 1.24 3.05 3.02 1.36 2.97 2.91 1.33<br />
16.0 22.0 3.89 3.52 1.07 3.73 3.41 1.08 3.52 3.29 1.31 3.42 3.18 1.40 3.28 3.09 1.46 3.19 2.99 1.39<br />
18.0 25.0 4.12 3.55 1.16 3.96 3.45 1.17 3.74 3.33 1.37 3.64 3.23 1.43 3.50 3.15 1.48 3.41 3.05 1.39<br />
19.0 27.0 4.23 3.58 1.17 4.07 3.48 1.18 3.85 3.37 1.39 3.74 3.26 1.43 3.61 3.19 1.49 3.53 3.09 1.39<br />
22.0 30.0 4.57 3.65 1.17 4.41 3.56 1.20 4.19 3.46 1.42 4.08 3.36 1.50 3.94 3.29 1.51 3.86 3.19 1.40<br />
24.0 32.0 4.80 3.72 1.16 4.63 3.63 1.21 4.41 3.54 1.45 4.31 3.44 1.53 4.17 3.37 1.54 4.08 3.28 1.43<br />
TC SHC PI<br />
2.89 2.82 1.19<br />
3.11 2.90 1.21<br />
3.33 2.96 1.18<br />
3.44 3.01 1.17<br />
3.77 3.12 1.17<br />
4.00 3.20 1.20<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 173
Capacity tables 5CSL0-06B<br />
Models : AUUW126D + ATNH12GRLED, AVNH12GELAD, AQNH12GALA0<br />
[UU12W ULD] + [UT12 NRD], [UV12 NED], [CQ12 NAD]<br />
• Heating Capacity<br />
Model ATNH12GRLED[UT12 NRD]<br />
AFR 9.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 3.13 1.77 3.34 1.80 3.73 1.71 4.11 1.60 4.47 1.50 4.76 1.47 4.89 1.39<br />
18 3.10 1.79 3.34 1.84 3.74 1.76 4.10 1.64 4.44 1.54 4.70 1.50 4.88 1.41<br />
20 3.08 1.82 3.34 1.89 3.74 1.81 4.09 1.68 4.40 1.57 4.67 1.52 4.88 1.42<br />
21 3.07 1.84 3.34 1.92 3.74 1.83 4.08 1.71 4.37 1.59 4.67 1.53 4.85 1.42<br />
22 3.07 1.86 3.34 1.94 3.74 1.86 4.07 1.73 4.34 1.60 4.67 1.54 4.81 1.42<br />
24 3.04 1.89 3.30 1.97 3.70 1.88 4.05 1.74 4.33 1.61 4.59 1.54 4.79 1.43<br />
Model AVNH12GELAD[UV12 NED]<br />
AFR 9.2<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 2.97 1.89 3.18 1.93 3.55 1.83 3.90 1.71 4.25 1.61 4.53 1.57 4.65 1.49<br />
18 2.95 1.92 3.17 1.98 3.55 1.89 3.90 1.76 4.22 1.65 4.47 1.61 4.63 1.51<br />
20 2.93 1.96 3.17 2.02 3.55 1.94 3.89 1.81 4.18 1.69 4.44 1.63 4.64 1.52<br />
21 2.92 1.97 3.17 2.05 3.55 1.97 3.88 1.83 4.15 1.70 4.44 1.64 4.61 1.52<br />
22 2.91 2.00 3.17 2.08 3.55 1.99 3.87 1.85 4.12 1.72 4.43 1.65 4.57 1.52<br />
24 2.89 2.03 3.14 2.11 3.51 2.02 3.85 1.87 4.12 1.73 4.36 1.65 4.55 1.53<br />
Model AQNH12GALA0[CQ12 NAD]<br />
AFR 9.0<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 3.13 1.73 3.34 1.77 3.73 1.68 4.11 1.57 4.47 1.48 4.76 1.44 4.89 1.37<br />
18 3.10 1.76 3.34 1.81 3.74 1.73 4.10 1.61 4.44 1.51 4.70 1.47 4.88 1.38<br />
20 3.08 1.79 3.34 1.85 3.74 1.78 4.09 1.65 4.40 1.54 4.67 1.49 4.88 1.39<br />
21 3.07 1.81 3.34 1.88 3.74 1.80 4.08 1.67 4.37 1.56 4.67 1.50 4.85 1.39<br />
22 3.07 1.83 3.34 1.91 3.74 1.83 4.07 1.70 4.34 1.57 4.67 1.51 4.81 1.39<br />
24 3.04 1.86 3.30 1.93 3.70 1.85 4.05 1.71 4.33 1.58 4.59 1.51 4.79 1.40<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
174 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW186D + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD, AQNH18GALA0<br />
[UU18W UED]+ [UT18 NQD], [UV18 NBD], [UB18 NHD], [CQ18 NAD]<br />
• Cooling Capacity<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.39 5.10 1.14 5.16 4.93 1.19 4.84 4.73 1.60 4.70 4.57 1.78 4.49 4.43 1.95 4.37 4.28 1.92<br />
16.0 22.0 5.72 5.16 1.54 5.49 5.01 1.56 5.17 4.82 1.88 5.02 4.67 2.02 4.82 4.54 2.11 4.69 4.39 2.00<br />
18.0 25.0 6.06 5.21 1.67 5.82 5.06 1.68 5.50 4.89 1.98 5.35 4.74 2.06 5.14 4.62 2.14 5.02 4.48 2.00<br />
19.0 27.0 6.22 5.25 1.69 5.98 5.11 1.70 5.67 4.95 2.00 5.50 4.79 2.06 5.31 4.68 2.14 5.18 4.54 2.00<br />
22.0 30.0 6.72 5.36 1.69 6.48 5.23 1.73 6.16 5.08 2.04 6.00 4.93 2.16 5.80 4.83 2.18 5.67 4.69 2.02<br />
24.0 32.0 7.05 5.46 1.68 6.81 5.33 1.75 6.49 5.19 2.08 6.33 5.05 2.20 6.13 4.95 2.22 6.00 4.82 2.06<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Indoor Air<br />
Temperature<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.33 4.51 1.12 5.10 4.36 1.17 4.79 4.18 1.58 4.64 4.04 1.76 4.44 3.92 1.93 4.32 3.78 1.89<br />
16.0 22.0 5.66 4.57 1.52 5.43 4.43 1.54 5.12 4.27 1.86 4.97 4.13 2.00 4.76 4.01 2.08 4.64 3.88 1.98<br />
18.0 25.0 5.99 4.61 1.65 5.76 4.48 1.66 5.44 4.32 1.95 5.29 4.19 2.03 5.09 4.09 2.11 4.97 3.96 1.98<br />
19.0 27.0 6.16 4.65 1.66 5.92 4.52 1.68 5.60 4.37 1.97 5.44 4.23 2.03 5.25 4.14 2.11 5.13 4.01 1.97<br />
22.0 30.0 6.65 4.74 1.66 6.41 4.62 1.71 6.09 4.49 2.02 5.94 4.36 2.13 5.74 4.27 2.15 5.61 4.15 1.99<br />
24.0 32.0 6.98 4.83 1.65 6.74 4.71 1.72 6.42 4.59 2.06 6.26 4.46 2.17 6.06 4.38 2.19 5.94 4.26 2.04<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
4.24 4.14 1.72<br />
4.57 4.26 1.74<br />
4.90 4.35 1.70<br />
5.06 4.42 1.68<br />
5.55 4.58 1.68<br />
5.88 4.70 1.72<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.18 4.46 1.09 4.95 4.32 1.13 4.65 4.15 1.52 4.51 4.01 1.70 4.31 3.88 1.87 4.19 3.75 1.83<br />
16.0 22.0 5.50 4.52 1.47 5.27 4.39 1.49 4.97 4.22 1.80 4.82 4.09 1.93 4.62 3.98 2.01 4.51 3.84 1.91<br />
18.0 25.0 5.81 4.56 1.59 5.59 4.43 1.60 5.28 4.28 1.89 5.14 4.15 1.97 4.94 4.05 2.04 4.82 3.92 1.91<br />
19.0 27.0 5.97 4.60 1.61 5.75 4.48 1.63 5.44 4.33 1.91 5.28 4.19 1.97 5.10 4.10 2.05 4.98 3.97 1.91<br />
22.0 30.0 6.45 4.69 1.61 6.22 4.58 1.65 5.91 4.45 1.95 5.76 4.32 2.06 5.57 4.23 2.08 5.45 4.11 1.93<br />
24.0 32.0 6.77 4.78 1.60 6.54 4.67 1.67 6.23 4.55 1.99 6.08 4.42 2.10 5.88 4.34 2.12 5.76 4.22 1.97<br />
TC SHC PI<br />
4.07 3.63 1.64<br />
4.39 3.73 1.66<br />
4.70 3.81 1.62<br />
4.86 3.87 1.61<br />
5.33 4.01 1.61<br />
5.64 4.12 1.65<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
4.20 3.67 1.70<br />
4.52 3.77 1.72<br />
4.84 3.85 1.68<br />
5.01 3.91 1.66<br />
5.49 4.05 1.66<br />
5.81 4.16 1.70<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 175
Capacity tables 5CSL0-06B<br />
Model AQNH18GALA0[CQ18 NAD]<br />
AFR 11.0<br />
Indoor Air<br />
Temperature<br />
• Symbol<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.39 4.80 1.14 5.16 4.65 1.19 4.84 4.46 1.60 4.70 4.31 1.79 4.49 4.18 1.96 4.37 4.03 1.92<br />
16.0 22.0 5.72 4.86 1.55 5.49 4.72 1.56 5.17 4.54 1.89 5.02 4.40 2.03 4.82 4.28 2.11 4.69 4.13 2.01<br />
18.0 25.0 6.06 4.91 1.67 5.82 4.77 1.68 5.50 4.61 1.98 5.35 4.47 2.07 5.14 4.35 2.14 5.02 4.22 2.01<br />
19.0 27.0 6.22 4.95 1.69 5.98 4.81 1.71 5.67 4.66 2.00 5.50 4.51 2.07 5.31 4.41 2.15 5.18 4.27 2.00<br />
22.0 30.0 6.72 5.05 1.69 6.48 4.92 1.74 6.16 4.78 2.05 6.00 4.65 2.17 5.80 4.55 2.18 5.67 4.42 2.02<br />
24.0 32.0 7.05 5.14 1.68 6.81 5.02 1.75 6.49 4.89 2.09 6.33 4.76 2.21 6.13 4.67 2.23 6.00 4.54 2.07<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
TC SHC PI<br />
4.24 3.90 1.72<br />
4.57 4.01 1.75<br />
4.90 4.10 1.70<br />
5.06 4.16 1.69<br />
5.55 4.31 1.69<br />
5.88 4.43 1.73<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
176 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW186D + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD, AQNH18GALA0<br />
[UU18W UED]+ [UT18 NQD], [UV18 NBD], [UB18 NHD], [CQ18 NAD]<br />
• Heating Capacity<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Indoor Air<br />
Temperature<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.31 2.44 4.60 2.49 5.13 2.36 5.65 2.20 6.15 2.08 6.55 2.03 6.73 1.93<br />
18 4.26 2.48 4.59 2.55 5.14 2.43 5.64 2.27 6.11 2.13 6.47 2.07 6.70 1.95<br />
20 4.24 2.52 4.59 2.61 5.14 2.50 5.63 2.33 6.05 2.17 6.43 2.10 6.72 1.96<br />
21 4.22 2.54 4.59 2.65 5.14 2.53 5.61 2.36 6.01 2.19 6.43 2.11 6.67 1.96<br />
22 4.22 2.57 4.59 2.69 5.14 2.57 5.60 2.39 5.97 2.21 6.42 2.12 6.62 1.96<br />
24 4.18 2.62 4.54 2.72 5.08 2.60 5.57 2.41 5.96 2.23 6.31 2.13 6.58 1.97<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 3.99 2.39 4.26 2.44 4.76 2.31 5.24 2.16 5.70 2.04 6.08 1.99 6.24 1.89<br />
18 3.95 2.43 4.25 2.50 4.77 2.38 5.23 2.22 5.66 2.09 6.00 2.03 6.22 1.91<br />
20 3.93 2.47 4.25 2.56 4.77 2.45 5.22 2.28 5.61 2.13 5.96 2.06 6.23 1.92<br />
21 3.92 2.49 4.25 2.59 4.77 2.48 5.21 2.31 5.57 2.15 5.96 2.07 6.19 1.92<br />
22 3.91 2.52 4.25 2.63 4.77 2.52 5.19 2.34 5.53 2.17 5.95 2.08 6.14 1.92<br />
24 3.87 2.56 4.21 2.67 4.71 2.55 5.16 2.36 5.53 2.18 5.85 2.09 6.10 1.93<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.70 2.67 5.01 2.71 5.60 2.58 6.16 2.41 6.71 2.27 7.15 2.21 7.34 2.10<br />
18 4.65 2.71 5.01 2.78 5.61 2.65 6.16 2.47 6.66 2.33 7.06 2.26 7.31 2.13<br />
20 4.62 2.75 5.01 2.85 5.61 2.73 6.14 2.54 6.60 2.37 7.01 2.29 7.33 2.14<br />
21 4.61 2.78 5.01 2.89 5.61 2.77 6.12 2.57 6.56 2.40 7.01 2.31 7.28 2.14<br />
22 4.60 2.81 5.01 2.93 5.61 2.81 6.11 2.61 6.51 2.41 7.00 2.32 7.22 2.14<br />
24 4.56 2.86 4.96 2.97 5.54 2.84 6.07 2.63 6.50 2.43 6.89 2.32 7.18 2.15<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 177
Capacity tables 5CSL0-06B<br />
Model AQNH18GALA0[CQ18 NAD]<br />
AFR 11.0<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.27 2.42 4.56 2.47 5.09 2.34 5.60 2.19 6.10 2.06 6.50 2.01 6.67 1.91<br />
18 4.23 2.46 4.55 2.53 5.10 2.41 5.60 2.25 6.06 2.12 6.42 2.05 6.65 1.93<br />
20 4.20 2.50 4.55 2.59 5.10 2.48 5.58 2.31 6.00 2.16 6.37 2.08 6.66 1.94<br />
21 4.19 2.53 4.55 2.63 5.10 2.52 5.57 2.34 5.96 2.18 6.37 2.10 6.62 1.95<br />
22 4.18 2.56 4.55 2.67 5.10 2.55 5.55 2.37 5.92 2.20 6.36 2.11 6.56 1.95<br />
24 4.14 2.60 4.51 2.70 5.04 2.59 5.52 2.39 5.91 2.21 6.26 2.11 6.53 1.96<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
178 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW186D1 + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD, AQNH18GALA0<br />
[UU18W UED1]+ [UT18 NQD], [UV18 NBD], [UB18 NHD], [CQ18 NAD]<br />
• Cooling Capacity<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.39 5.10 1.14 5.16 4.93 1.19 4.84 4.73 1.60 4.70 4.57 1.78 4.49 4.43 1.95 4.37 4.28 1.92<br />
16.0 22.0 5.72 5.16 1.54 5.49 5.01 1.56 5.17 4.82 1.88 5.02 4.67 2.02 4.82 4.54 2.11 4.69 4.39 2.00<br />
18.0 25.0 6.06 5.21 1.67 5.82 5.06 1.68 5.50 4.89 1.98 5.35 4.74 2.06 5.14 4.62 2.14 5.02 4.48 2.00<br />
19.0 27.0 6.22 5.25 1.69 5.98 5.11 1.70 5.67 4.95 2.00 5.50 4.79 2.06 5.31 4.68 2.14 5.18 4.54 2.00<br />
22.0 30.0 6.72 5.36 1.69 6.48 5.23 1.73 6.16 5.08 2.04 6.00 4.93 2.16 5.80 4.83 2.18 5.67 4.69 2.02<br />
24.0 32.0 7.05 5.46 1.68 6.81 5.33 1.75 6.49 5.19 2.08 6.33 5.05 2.20 6.13 4.95 2.22 6.00 4.82 2.06<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Indoor Air<br />
Temperature<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.33 4.51 1.12 5.10 4.36 1.17 4.79 4.18 1.58 4.64 4.04 1.76 4.44 3.92 1.93 4.32 3.78 1.89<br />
16.0 22.0 5.66 4.57 1.52 5.43 4.43 1.54 5.12 4.27 1.86 4.97 4.13 2.00 4.76 4.01 2.08 4.64 3.88 1.98<br />
18.0 25.0 5.99 4.61 1.65 5.76 4.48 1.66 5.44 4.32 1.95 5.29 4.19 2.03 5.09 4.09 2.11 4.97 3.96 1.98<br />
19.0 27.0 6.16 4.65 1.66 5.92 4.52 1.68 5.60 4.37 1.97 5.44 4.23 2.03 5.25 4.14 2.11 5.13 4.01 1.97<br />
22.0 30.0 6.65 4.74 1.66 6.41 4.62 1.71 6.09 4.49 2.02 5.94 4.36 2.13 5.74 4.27 2.15 5.61 4.15 1.99<br />
24.0 32.0 6.98 4.83 1.65 6.74 4.71 1.72 6.42 4.59 2.06 6.26 4.46 2.17 6.06 4.38 2.19 5.94 4.26 2.04<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
4.24 4.14 1.72<br />
4.57 4.26 1.74<br />
4.90 4.35 1.70<br />
5.06 4.42 1.68<br />
5.55 4.58 1.68<br />
5.88 4.70 1.72<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.18 4.46 1.09 4.95 4.32 1.13 4.65 4.15 1.52 4.51 4.01 1.70 4.31 3.88 1.87 4.19 3.75 1.83<br />
16.0 22.0 5.50 4.52 1.47 5.27 4.39 1.49 4.97 4.22 1.80 4.82 4.09 1.93 4.62 3.98 2.01 4.51 3.84 1.91<br />
18.0 25.0 5.81 4.56 1.59 5.59 4.43 1.60 5.28 4.28 1.89 5.14 4.15 1.97 4.94 4.05 2.04 4.82 3.92 1.91<br />
19.0 27.0 5.97 4.60 1.61 5.75 4.48 1.63 5.44 4.33 1.91 5.28 4.19 1.97 5.10 4.10 2.05 4.98 3.97 1.91<br />
22.0 30.0 6.45 4.69 1.61 6.22 4.58 1.65 5.91 4.45 1.95 5.76 4.32 2.06 5.57 4.23 2.08 5.45 4.11 1.93<br />
24.0 32.0 6.77 4.78 1.60 6.54 4.67 1.67 6.23 4.55 1.99 6.08 4.42 2.10 5.88 4.34 2.12 5.76 4.22 1.97<br />
TC SHC PI<br />
4.07 3.63 1.64<br />
4.39 3.73 1.66<br />
4.70 3.81 1.62<br />
4.86 3.87 1.61<br />
5.33 4.01 1.61<br />
5.64 4.12 1.65<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
4.20 3.67 1.70<br />
4.52 3.77 1.72<br />
4.84 3.85 1.68<br />
5.01 3.91 1.66<br />
5.49 4.05 1.66<br />
5.81 4.16 1.70<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 179
Capacity tables 5CSL0-06B<br />
Model AQNH18GALA0[CQ18 NAD]<br />
AFR 11.0<br />
Indoor Air<br />
Temperature<br />
• Symbol<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.39 4.80 1.14 5.16 4.65 1.19 4.84 4.46 1.60 4.70 4.31 1.79 4.49 4.18 1.96 4.37 4.03 1.92<br />
16.0 22.0 5.72 4.86 1.55 5.49 4.72 1.56 5.17 4.54 1.89 5.02 4.40 2.03 4.82 4.28 2.11 4.69 4.13 2.01<br />
18.0 25.0 6.06 4.91 1.67 5.82 4.77 1.68 5.50 4.61 1.98 5.35 4.47 2.07 5.14 4.35 2.14 5.02 4.22 2.01<br />
19.0 27.0 6.22 4.95 1.69 5.98 4.81 1.71 5.67 4.66 2.00 5.50 4.51 2.07 5.31 4.41 2.15 5.18 4.27 2.00<br />
22.0 30.0 6.72 5.05 1.69 6.48 4.92 1.74 6.16 4.78 2.05 6.00 4.65 2.17 5.80 4.55 2.18 5.67 4.42 2.02<br />
24.0 32.0 7.05 5.14 1.68 6.81 5.02 1.75 6.49 4.89 2.09 6.33 4.76 2.21 6.13 4.67 2.23 6.00 4.54 2.07<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
TC SHC PI<br />
4.24 3.90 1.72<br />
4.57 4.01 1.75<br />
4.90 4.10 1.70<br />
5.06 4.16 1.69<br />
5.55 4.31 1.69<br />
5.88 4.43 1.73<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
180 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW186D1 + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD, AQNH18GALA0<br />
[UU18W UED1]+ [UT18 NQD], [UV18 NBD], [UB18 NHD], [CQ18 NAD]<br />
• Heating Capacity<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Indoor Air<br />
Temperature<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.31 2.44 4.60 2.49 5.13 2.36 5.65 2.20 6.15 2.08 6.55 2.03 6.73 1.93<br />
18 4.26 2.48 4.59 2.55 5.14 2.43 5.64 2.27 6.11 2.13 6.47 2.07 6.70 1.95<br />
20 4.24 2.52 4.59 2.61 5.14 2.50 5.63 2.33 6.05 2.17 6.43 2.10 6.72 1.96<br />
21 4.22 2.54 4.59 2.65 5.14 2.53 5.61 2.36 6.01 2.19 6.43 2.11 6.67 1.96<br />
22 4.22 2.57 4.59 2.69 5.14 2.57 5.60 2.39 5.97 2.21 6.42 2.12 6.62 1.96<br />
24 4.18 2.62 4.54 2.72 5.08 2.60 5.57 2.41 5.96 2.23 6.31 2.13 6.58 1.97<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 3.99 2.39 4.26 2.44 4.76 2.31 5.24 2.16 5.70 2.04 6.08 1.99 6.24 1.89<br />
18 3.95 2.43 4.25 2.50 4.77 2.38 5.23 2.22 5.66 2.09 6.00 2.03 6.22 1.91<br />
20 3.93 2.47 4.25 2.56 4.77 2.45 5.22 2.28 5.61 2.13 5.96 2.06 6.23 1.92<br />
21 3.92 2.49 4.25 2.59 4.77 2.48 5.21 2.31 5.57 2.15 5.96 2.07 6.19 1.92<br />
22 3.91 2.52 4.25 2.63 4.77 2.52 5.19 2.34 5.53 2.17 5.95 2.08 6.14 1.92<br />
24 3.87 2.56 4.21 2.67 4.71 2.55 5.16 2.36 5.53 2.18 5.85 2.09 6.10 1.93<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.70 2.67 5.01 2.71 5.60 2.58 6.16 2.41 6.71 2.27 7.15 2.21 7.34 2.10<br />
18 4.65 2.71 5.01 2.78 5.61 2.65 6.16 2.47 6.66 2.33 7.06 2.26 7.31 2.13<br />
20 4.62 2.75 5.01 2.85 5.61 2.73 6.14 2.54 6.60 2.37 7.01 2.29 7.33 2.14<br />
21 4.61 2.78 5.01 2.89 5.61 2.77 6.12 2.57 6.56 2.40 7.01 2.31 7.28 2.14<br />
22 4.60 2.81 5.01 2.93 5.61 2.81 6.11 2.61 6.51 2.41 7.00 2.32 7.22 2.14<br />
24 4.56 2.86 4.96 2.97 5.54 2.84 6.07 2.63 6.50 2.43 6.89 2.32 7.18 2.15<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 181
Capacity tables 5CSL0-06B<br />
Model AQNH18GALA0[CQ18 NAD]<br />
AFR 11.0<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.27 2.42 4.56 2.47 5.09 2.34 5.60 2.19 6.10 2.06 6.50 2.01 6.67 1.91<br />
18 4.23 2.46 4.55 2.53 5.10 2.41 5.60 2.25 6.06 2.12 6.42 2.05 6.65 1.93<br />
20 4.20 2.50 4.55 2.59 5.10 2.48 5.58 2.31 6.00 2.16 6.37 2.08 6.66 1.94<br />
21 4.19 2.53 4.55 2.63 5.10 2.52 5.57 2.34 5.96 2.18 6.37 2.10 6.62 1.95<br />
22 4.18 2.56 4.55 2.67 5.10 2.55 5.55 2.37 5.92 2.20 6.36 2.11 6.56 1.95<br />
24 4.14 2.60 4.51 2.70 5.04 2.59 5.52 2.39 5.91 2.21 6.26 2.11 6.53 1.96<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
182 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW246D +ATNH24GPLED, UVNH246BLAD , ABNH246HLAD<br />
[UU24W UED]+ [UT24 NPD], [UV24 NBD], [UB24 NHD]<br />
• Cooling Capacity<br />
Model ATNH24GPLED[UT24 NPD]<br />
AFR 17<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 7.66 6.55 1.57 7.32 6.34 1.64 6.88 6.08 2.20 6.67 5.88 2.45 6.38 5.70 2.69 6.20 5.50 2.64<br />
16.0 22.0 8.13 6.64 2.13 7.79 6.44 2.14 7.34 6.20 2.59 7.13 6.00 2.79 6.84 5.83 2.90 6.66 5.64 2.76<br />
18.0 25.0 8.60 6.69 2.30 8.26 6.50 2.31 7.81 6.28 2.72 7.60 6.09 2.84 7.30 5.94 2.94 7.13 5.75 2.76<br />
19.0 27.0 8.84 6.75 2.32 8.50 6.57 2.34 8.04 6.36 2.75 7.81 6.15 2.84 7.54 6.02 2.95 7.36 5.83 2.75<br />
22.0 30.0 9.54 6.89 2.32 9.20 6.72 2.39 8.74 6.52 2.82 8.53 6.34 2.98 8.23 6.21 3.00 8.06 6.03 2.78<br />
24.0 32.0 10.02 7.01 2.31 9.67 6.85 2.41 9.21 6.67 2.87 8.99 6.49 3.03 8.70 6.37 3.06 8.52 6.19 2.84<br />
Model UVNH246BLAD[UV24 NBD]<br />
AFR 15<br />
Indoor Air<br />
Temperature<br />
Model ABNH246HLAD[UB24 NHD]<br />
AFR 18<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 7.55 5.61 1.68 7.22 5.43 1.75 6.78 5.21 2.35 6.57 5.04 2.62 6.29 4.88 2.88 6.11 4.71 2.82<br />
16.0 22.0 8.01 5.69 2.27 7.68 5.51 2.29 7.24 5.31 2.77 7.03 5.14 2.98 6.74 5.00 3.11 6.57 4.83 2.96<br />
18.0 25.0 8.48 5.74 2.46 8.15 5.57 2.47 7.70 5.39 2.91 7.49 5.22 3.04 7.20 5.09 3.15 7.03 4.93 2.95<br />
19.0 27.0 8.71 5.79 2.49 8.38 5.63 2.51 7.93 5.45 2.94 7.70 5.27 3.04 7.43 5.16 3.16 7.26 5.00 2.94<br />
22.0 30.0 9.41 5.90 2.49 9.07 5.75 2.55 8.62 5.59 3.01 8.41 5.43 3.18 8.12 5.32 3.21 7.94 5.16 2.97<br />
24.0 32.0 9.87 6.01 2.47 9.53 5.87 2.57 9.08 5.72 3.07 8.86 5.56 3.25 8.58 5.45 3.28 8.40 5.30 3.04<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
6.02 5.33 2.37<br />
6.49 5.48 2.40<br />
6.95 5.59 2.34<br />
7.19 5.68 2.32<br />
7.88 5.88 2.32<br />
8.35 6.04 2.38<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
5.94 4.56 2.53<br />
6.40 4.69 2.57<br />
6.86 4.79 2.50<br />
7.08 4.86 2.48<br />
7.77 5.04 2.48<br />
8.23 5.18 2.54<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 7.66 5.99 1.91 7.32 5.79 2.00 6.88 5.56 2.68 6.67 5.37 2.99 6.38 5.21 3.28 6.20 5.03 3.22<br />
16.0 22.0 8.13 6.07 2.59 7.79 5.88 2.61 7.34 5.67 3.16 7.13 5.48 3.39 6.84 5.33 3.54 6.66 5.16 3.37<br />
18.0 25.0 8.60 6.12 2.80 8.26 5.95 2.82 7.81 5.75 3.32 7.60 5.57 3.46 7.30 5.43 3.59 7.13 5.26 3.36<br />
19.0 27.0 8.84 6.17 2.83 8.50 6.00 2.86 8.04 5.81 3.35 7.81 5.62 3.46 7.54 5.50 3.60 7.36 5.33 3.35<br />
22.0 30.0 9.54 6.29 2.83 9.20 6.14 2.91 8.74 5.96 3.43 8.53 5.79 3.63 8.23 5.67 3.65 8.06 5.51 3.39<br />
24.0 32.0 10.02 6.41 2.82 9.67 6.26 2.93 9.21 6.10 3.50 8.99 5.93 3.70 8.70 5.82 3.73 8.52 5.66 3.46<br />
TC SHC PI<br />
6.02 4.87 2.89<br />
6.49 5.01 2.92<br />
6.95 5.11 2.85<br />
7.19 5.19 2.83<br />
7.88 5.37 2.83<br />
8.35 5.52 2.90<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 183
Capacity tables 5CSL0-06B<br />
Models : AUUW246D +ATNH24GPLED, UVNH246BLAD , ABNH246HLAD<br />
[UU24W UED]+ [UT24 NPD], [UV24 NBD], [UB24 NHD]<br />
• Heating Capacity<br />
Model ATNH24GPLED[UT24 NPD]<br />
AFR 17<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.26 3.76 6.68 3.83 7.47 3.63 8.21 3.39 8.95 3.20 9.53 3.12 9.78 2.96<br />
18 6.20 3.81 6.67 3.92 7.48 3.74 8.21 3.49 8.89 3.28 9.41 3.18 9.75 3.00<br />
20 6.16 3.88 6.67 4.02 7.48 3.85 8.18 3.58 8.80 3.35 9.35 3.23 9.77 3.01<br />
21 6.14 3.92 6.67 4.07 7.48 3.90 8.17 3.63 8.74 3.38 9.35 3.25 9.71 3.02<br />
22 6.13 3.96 6.67 4.13 7.48 3.96 8.14 3.67 8.68 3.40 9.34 3.27 9.63 3.02<br />
24 6.07 4.03 6.61 4.19 7.39 4.01 8.10 3.71 8.67 3.43 9.18 3.27 9.57 3.03<br />
Model UVNH246BLAD[UV24 NBD]<br />
AFR 15<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.03 4.06 6.43 4.14 7.19 3.93 7.90 3.67 8.61 3.46 9.17 3.37 9.42 3.20<br />
18 5.97 4.12 6.42 4.24 7.20 4.04 7.90 3.77 8.55 3.55 9.06 3.44 9.39 3.24<br />
20 5.93 4.20 6.42 4.34 7.20 4.16 7.88 3.87 8.47 3.62 9.00 3.49 9.40 3.26<br />
21 5.91 4.23 6.42 4.40 7.20 4.22 7.86 3.92 8.42 3.65 9.00 3.52 9.34 3.26<br />
22 5.90 4.28 6.42 4.47 7.20 4.28 7.84 3.97 8.36 3.68 8.98 3.53 9.27 3.26<br />
24 5.85 4.35 6.36 4.53 7.11 4.33 7.79 4.01 8.34 3.70 8.84 3.54 9.21 3.28<br />
Model ABNH246HLAD[UB24 NHD]<br />
AFR 18<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.26 4.08 6.68 4.15 7.47 3.94 8.21 3.68 8.95 3.47 9.53 3.39 9.78 3.21<br />
18 6.20 4.14 6.67 4.25 7.48 4.06 8.21 3.78 8.89 3.56 9.41 3.45 9.75 3.25<br />
20 6.16 4.21 6.67 4.36 7.48 4.17 8.18 3.88 8.80 3.63 9.35 3.50 9.77 3.27<br />
21 6.14 4.25 6.67 4.42 7.48 4.23 8.17 3.93 8.74 3.67 9.35 3.53 9.71 3.27<br />
22 6.13 4.30 6.67 4.48 7.48 4.29 8.14 3.99 8.68 3.69 9.34 3.54 9.63 3.27<br />
24 6.07 4.37 6.61 4.55 7.39 4.35 8.10 4.02 8.67 3.72 9.18 3.55 9.57 3.29<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
184 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW306D +ATNH30GPLED, UVNH306BLAD , ABNH306GLAD<br />
[UU30W UED]+ [UT30NPD], [UV30 NBD], [UB30 NGD]<br />
• Cooling Capacity<br />
Model ATNH30GPLED[UT30 NPD]<br />
AFR 19<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.63 7.22 1.93 8.25 6.98 2.02 7.75 6.70 2.71 7.51 6.48 3.02 7.18 6.28 3.32 6.99 6.06 3.25<br />
16.0 22.0 9.16 7.31 2.62 8.78 7.09 2.64 8.28 6.83 3.20 8.04 6.61 3.43 7.71 6.43 3.58 7.51 6.21 3.41<br />
18.0 25.0 9.69 7.38 2.83 9.31 7.17 2.85 8.80 6.93 3.36 8.56 6.71 3.50 8.23 6.54 3.63 8.03 6.34 3.40<br />
19.0 27.0 9.96 7.44 2.86 9.58 7.24 2.89 9.06 7.00 3.39 8.80 6.78 3.50 8.49 6.63 3.64 8.29 6.43 3.39<br />
22.0 30.0 10.75 7.59 2.86 10.37 7.40 2.94 9.85 7.19 3.47 9.61 6.99 3.67 9.28 6.84 3.70 9.08 6.64 3.43<br />
24.0 32.0 11.28 7.73 2.85 10.90 7.55 2.97 10.38 7.35 3.54 10.13 7.15 3.74 9.80 7.01 3.77 9.60 6.82 3.50<br />
Model UVNH306BLAD[UV30 NBD]<br />
AFR 18<br />
Indoor Air<br />
Temperature<br />
Model ABNH306GLAD[UB30 NGD]<br />
AFR 26.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.20 6.23 1.95 7.84 6.03 2.04 7.36 5.79 2.74 7.14 5.59 3.06 6.82 5.42 3.36 6.64 5.23 3.29<br />
16.0 22.0 8.70 6.32 2.65 8.34 6.12 2.67 7.86 5.90 3.23 7.63 5.71 3.47 7.32 5.55 3.62 7.13 5.37 3.44<br />
18.0 25.0 9.21 6.37 2.86 8.85 6.19 2.88 8.36 5.98 3.39 8.13 5.80 3.54 7.82 5.65 3.67 7.63 5.47 3.44<br />
19.0 27.0 9.46 6.43 2.90 9.10 6.25 2.92 8.61 6.05 3.43 8.36 5.85 3.54 8.07 5.73 3.68 7.88 5.55 3.43<br />
22.0 30.0 10.22 6.55 2.90 9.85 6.39 2.97 9.36 6.21 3.51 9.13 6.03 3.71 8.81 5.91 3.74 8.63 5.74 3.46<br />
24.0 32.0 10.72 6.68 2.88 10.35 6.52 3.00 9.86 6.35 3.58 9.62 6.17 3.78 9.31 6.06 3.82 9.12 5.89 3.54<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
6.79 5.87 2.92<br />
7.31 6.03 2.96<br />
7.84 6.16 2.89<br />
8.10 6.25 2.86<br />
8.88 6.48 2.86<br />
9.41 6.66 2.93<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
6.45 5.07 2.95<br />
6.95 5.21 2.99<br />
7.44 5.32 2.92<br />
7.69 5.40 2.89<br />
8.44 5.60 2.89<br />
8.94 5.75 2.96<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.63 7.69 1.93 8.25 7.44 2.02 7.75 7.14 2.71 7.51 6.90 3.02 7.18 6.69 3.32 6.99 6.45 3.25<br />
16.0 22.0 9.16 7.79 2.62 8.78 7.55 2.64 8.28 7.27 3.20 8.04 7.04 3.43 7.71 6.85 3.58 7.51 6.62 3.41<br />
18.0 25.0 9.69 7.85 2.83 9.31 7.63 2.85 8.80 7.38 3.36 8.56 7.15 3.50 8.23 6.97 3.63 8.03 6.75 3.40<br />
19.0 27.0 9.96 7.92 2.86 9.58 7.71 2.89 9.06 7.46 3.39 8.80 7.22 3.50 8.49 7.06 3.64 8.29 6.84 3.39<br />
22.0 30.0 10.75 8.08 2.86 10.37 7.88 2.94 9.85 7.66 3.47 9.61 7.44 3.67 9.28 7.28 3.70 9.08 7.07 3.43<br />
24.0 32.0 11.28 8.23 2.85 10.90 8.04 2.97 10.38 7.83 3.54 10.13 7.61 3.74 9.80 7.47 3.77 9.60 7.26 3.50<br />
TC SHC PI<br />
6.79 6.25 2.92<br />
7.31 6.43 2.96<br />
7.84 6.56 2.89<br />
8.10 6.66 2.86<br />
8.88 6.90 2.86<br />
9.41 7.09 2.93<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 185
Capacity tables 5CSL0-06B<br />
Models : AUUW306D +ATNH30GPLED, UVNH306BLAD , ABNH306GLAD<br />
[UU30W UED]+ [UT30NPD], [UV30 NBD], [UB30 NGD]<br />
• Heating Capacity<br />
Model ATNH30GPLED[UT30 NPD]<br />
AFR 19<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 7.04 4.50 7.52 4.58 8.40 4.35 9.24 4.06 10.07 3.83 10.72 3.73 11.01 3.55<br />
18 6.98 4.56 7.51 4.69 8.42 4.48 9.23 4.17 10.00 3.93 10.59 3.81 10.97 3.59<br />
20 6.93 4.64 7.51 4.80 8.42 4.60 9.21 4.28 9.90 4.00 10.51 3.86 10.99 3.60<br />
21 6.91 4.69 7.51 4.88 8.42 4.67 9.19 4.34 9.84 4.04 10.51 3.89 10.92 3.61<br />
22 6.90 4.74 7.51 4.95 8.42 4.73 9.16 4.40 9.77 4.07 10.50 3.91 10.83 3.61<br />
24 6.83 4.82 7.43 5.01 8.31 4.79 9.11 4.44 9.75 4.10 10.33 3.92 10.77 3.63<br />
Model UVNH306BLAD[UV30 NBD]<br />
AFR 18<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.58 4.80 7.02 4.89 7.84 4.64 8.62 4.34 9.39 4.09 10.01 3.99 10.27 3.79<br />
18 6.51 4.87 7.01 5.01 7.85 4.78 8.62 4.46 9.33 4.19 9.88 4.07 10.24 3.83<br />
20 6.47 4.96 7.01 5.13 7.85 4.92 8.59 4.57 9.24 4.28 9.81 4.13 10.26 3.85<br />
21 6.45 5.00 7.01 5.21 7.85 4.99 8.57 4.63 9.18 4.32 9.81 4.16 10.19 3.86<br />
22 6.44 5.06 7.01 5.28 7.85 5.05 8.55 4.69 9.11 4.35 9.80 4.18 10.11 3.86<br />
24 6.38 5.15 6.94 5.35 7.76 5.12 8.50 4.74 9.10 4.38 9.64 4.18 10.05 3.87<br />
Model ABNH306GLAD[UB30 NGD]<br />
AFR 26.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 7.04 4.00 7.52 4.07 8.40 3.87 9.24 3.61 10.07 3.40 10.72 3.32 11.01 3.15<br />
18 6.98 4.06 7.51 4.17 8.42 3.98 9.23 3.71 10.00 3.49 10.59 3.39 10.97 3.19<br />
20 6.93 4.13 7.51 4.27 8.42 4.09 9.21 3.81 9.90 3.56 10.51 3.44 10.99 3.20<br />
21 6.91 4.17 7.51 4.34 8.42 4.15 9.19 3.86 9.84 3.60 10.51 3.46 10.92 3.21<br />
22 6.90 4.21 7.51 4.40 8.42 4.21 9.16 3.91 9.77 3.62 10.50 3.48 10.83 3.21<br />
24 6.83 4.29 7.43 4.46 8.31 4.26 9.11 3.95 9.75 3.65 10.33 3.48 10.77 3.23<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
186 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW366D +ATNH36GNLED , UVNH366KLAD, ABNH366GLAD<br />
[UU36W UED]+ [UT36 NND] , [UV36 NKD] , [ UB36 NGD]<br />
• Cooling Capacity<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.79 9.49 2.27 10.32 9.18 2.38 9.69 8.81 3.19 9.39 8.52 3.56 8.98 8.26 3.91 8.73 7.97 3.83<br />
16.0 22.0 11.45 9.61 3.08 10.98 9.33 3.11 10.34 8.98 3.76 10.05 8.69 4.04 9.63 8.45 4.21 9.39 8.17 4.01<br />
18.0 25.0 12.11 9.70 3.33 11.64 9.43 3.35 11.00 9.11 3.95 10.70 8.83 4.12 10.29 8.61 4.27 10.04 8.33 4.00<br />
19.0 27.0 12.45 9.78 3.37 11.97 9.52 3.40 11.33 9.21 3.99 11.00 8.91 4.12 10.62 8.72 4.28 10.37 8.45 3.99<br />
22.0 30.0 13.44 9.98 3.37 12.96 9.73 3.46 12.32 9.45 4.09 12.01 9.19 4.32 11.60 8.99 4.35 11.35 8.73 4.03<br />
24.0 32.0 14.11 10.16 3.35 13.62 9.93 3.49 12.97 9.67 4.16 12.66 9.40 4.40 12.25 9.22 4.44 12.00 8.97 4.12<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Indoor Air<br />
Temperature<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.30 8.50 2.42 9.85 8.22 2.53 9.25 7.89 3.40 8.96 7.63 3.79 8.57 7.39 4.16 8.34 7.13 4.08<br />
16.0 22.0 10.93 8.61 3.28 10.48 8.35 3.31 9.87 8.04 4.00 9.59 7.79 4.30 9.20 7.57 4.48 8.96 7.32 4.27<br />
18.0 25.0 11.56 8.69 3.55 11.11 8.44 3.57 10.50 8.16 4.20 10.21 7.91 4.38 9.82 7.71 4.55 9.58 7.46 4.26<br />
19.0 27.0 11.88 8.76 3.59 11.42 8.52 3.62 10.82 8.25 4.25 10.50 7.98 4.38 10.13 7.81 4.56 9.90 7.57 4.25<br />
22.0 30.0 12.83 8.94 3.59 12.37 8.72 3.68 11.76 8.47 4.35 11.46 8.23 4.59 11.07 8.06 4.63 10.83 7.82 4.29<br />
24.0 32.0 13.46 9.10 3.57 13.00 8.89 3.72 12.38 8.66 4.43 12.09 8.42 4.69 11.69 8.26 4.73 11.46 8.03 4.39<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
8.49 7.72 3.44<br />
9.14 7.93 3.48<br />
9.79 8.11 3.40<br />
10.12 8.22 3.37<br />
11.10 8.52 3.37<br />
11.76 8.76 3.45<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
8.10 6.91 3.66<br />
8.72 7.11 3.70<br />
9.35 7.26 3.62<br />
9.66 7.37 3.58<br />
10.60 7.63 3.58<br />
11.22 7.84 3.67<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.79 9.25 2.37 10.32 8.95 2.47 9.69 8.59 3.32 9.39 8.30 3.71 8.98 8.05 4.07 8.73 7.77 3.99<br />
16.0 22.0 11.45 9.38 3.21 10.98 9.09 3.24 10.34 8.76 3.92 10.05 8.48 4.21 9.63 8.24 4.39 9.39 7.97 4.18<br />
18.0 25.0 12.11 9.46 3.47 11.64 9.19 3.49 11.00 8.88 4.12 10.70 8.61 4.29 10.29 8.39 4.45 10.04 8.13 4.17<br />
19.0 27.0 12.45 9.54 3.51 11.97 9.28 3.54 11.33 8.98 4.16 11.00 8.69 4.29 10.62 8.50 4.46 10.37 8.24 4.16<br />
22.0 30.0 13.44 9.73 3.51 12.96 9.49 3.61 12.32 9.22 4.26 12.01 8.96 4.50 11.60 8.77 4.53 11.35 8.52 4.20<br />
24.0 32.0 14.11 9.91 3.49 13.62 9.68 3.64 12.97 9.42 4.34 12.66 9.17 4.59 12.25 8.99 4.63 12.00 8.74 4.30<br />
TC SHC PI<br />
8.49 7.53 3.58<br />
9.14 7.74 3.62<br />
9.79 7.90 3.54<br />
10.12 8.02 3.51<br />
11.10 8.31 3.51<br />
11.76 8.54 3.59<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 187
Capacity tables 5CSL0-06B<br />
Models : AUUW366D +ATNH36GNLED , UVNH366KLAD, ABNH366GLAD<br />
[UU36W UED]+ [UT36 NND] , [UV36 NKD] , [ UB36 NGD]<br />
• Heating Capacity<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.61 5.19 9.19 5.28 10.27 5.02 11.29 4.68 12.30 4.41 13.10 4.31 13.45 4.09<br />
18 8.53 5.26 9.18 5.41 10.29 5.16 11.28 4.81 12.22 4.53 12.94 4.39 13.41 4.14<br />
20 8.47 5.36 9.18 5.54 10.29 5.31 11.25 4.94 12.10 4.62 12.85 4.46 13.43 4.16<br />
21 8.45 5.40 9.18 5.62 10.29 5.39 11.23 5.01 12.02 4.66 12.85 4.49 13.35 4.17<br />
22 8.43 5.47 9.18 5.71 10.29 5.46 11.20 5.07 11.94 4.70 12.84 4.51 13.24 4.17<br />
24 8.35 5.56 9.09 5.78 10.16 5.53 11.13 5.12 11.92 4.73 12.62 4.52 13.16 4.19<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.25 5.25 8.81 5.35 9.85 5.08 10.83 4.74 11.79 4.47 12.56 4.36 12.90 4.14<br />
18 8.18 5.33 8.80 5.48 9.86 5.23 10.82 4.87 11.71 4.58 12.40 4.45 12.85 4.19<br />
20 8.12 5.42 8.80 5.61 9.86 5.38 10.79 5.00 11.60 4.68 12.32 4.51 12.88 4.21<br />
21 8.10 5.47 8.80 5.69 9.86 5.45 10.77 5.07 11.53 4.72 12.32 4.54 12.80 4.22<br />
22 8.08 5.53 8.80 5.78 9.86 5.53 10.73 5.13 11.44 4.76 12.31 4.57 12.69 4.22<br />
24 8.01 5.63 8.71 5.86 9.74 5.60 10.67 5.18 11.43 4.79 12.10 4.58 12.62 4.24<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.75 5.27 9.34 5.36 10.44 5.09 11.48 4.76 12.51 4.48 13.32 4.38 13.68 4.15<br />
18 8.67 5.35 9.33 5.50 10.46 5.24 11.47 4.89 12.42 4.60 13.15 4.46 13.63 4.20<br />
20 8.61 5.44 9.33 5.63 10.46 5.39 11.44 5.02 12.30 4.69 13.06 4.53 13.65 4.22<br />
21 8.59 5.49 9.33 5.71 10.46 5.47 11.41 5.08 12.22 4.74 13.06 4.56 13.57 4.23<br />
22 8.57 5.55 9.33 5.79 10.46 5.54 11.38 5.15 12.13 4.77 13.05 4.58 13.46 4.23<br />
24 8.49 5.65 9.24 5.87 10.33 5.62 11.32 5.20 12.12 4.80 12.83 4.59 13.38 4.25<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
188 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW426D +ATNH42GMLED , UVNH426LLAD, ABNH426RLAD<br />
[UU42W U3D]+ [UT42 NMD], [UV42 NLD] , [UB42 NRD]<br />
• Cooling Capacity<br />
Model ATNH42GMLED[UT42 NMD]<br />
AFR 30<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 11.76 2.84 12.94 11.38 2.96 12.15 10.92 3.98 11.78 10.55 4.44 11.27 10.23 4.87 10.96 9.87 4.78<br />
16.0 22.0 14.36 11.91 3.85 13.77 11.55 3.88 12.98 11.13 4.69 12.60 10.77 5.04 12.09 10.47 5.25 11.78 10.13 5.00<br />
18.0 25.0 15.20 12.02 4.16 14.60 11.68 4.18 13.80 11.28 4.93 13.42 10.94 5.13 12.91 10.66 5.33 12.60 10.33 4.99<br />
19.0 27.0 15.61 12.12 4.21 15.02 11.79 4.24 14.21 11.41 4.98 13.80 11.04 5.13 13.32 10.80 5.34 13.01 10.47 4.98<br />
22.0 30.0 16.86 12.36 4.20 16.26 12.06 4.32 15.45 11.71 5.10 15.07 11.38 5.38 14.55 11.14 5.42 14.24 10.82 5.03<br />
24.0 32.0 17.70 12.59 4.18 17.09 12.30 4.35 16.28 11.98 5.19 15.89 11.65 5.49 15.37 11.43 5.54 15.06 11.11 5.14<br />
Model UVNH426LLAD[UV42 NLD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Model ABNH426RLAD[UB42 NRD]<br />
AFR 36<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 11.03 2.92 12.94 10.67 3.05 12.15 10.24 4.09 11.78 9.90 4.56 11.27 9.60 5.01 10.96 9.26 4.91<br />
16.0 22.0 14.36 11.17 3.95 13.77 10.84 3.99 12.98 10.44 4.82 12.60 10.10 5.18 12.09 9.82 5.40 11.78 9.50 5.14<br />
18.0 25.0 15.20 11.27 4.28 14.60 10.95 4.30 13.80 10.58 5.07 13.42 10.26 5.28 12.91 10.00 5.48 12.60 9.69 5.13<br />
19.0 27.0 15.61 11.37 4.32 15.02 11.06 4.36 14.21 10.70 5.12 13.80 10.36 5.28 13.32 10.13 5.49 13.01 9.82 5.12<br />
22.0 30.0 16.86 11.60 4.32 16.26 11.31 4.44 15.45 10.99 5.24 15.07 10.68 5.53 14.55 10.45 5.58 14.24 10.15 5.17<br />
24.0 32.0 17.70 11.81 4.30 17.09 11.54 4.48 16.28 11.23 5.34 15.89 10.93 5.65 15.37 10.72 5.70 15.06 10.42 5.29<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
10.65 9.56 4.29<br />
11.47 9.83 4.34<br />
12.29 10.04 4.24<br />
12.70 10.19 4.20<br />
13.93 10.56 4.20<br />
14.75 10.85 4.30<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
10.65 8.97 4.41<br />
11.47 9.22 4.46<br />
12.29 9.42 4.36<br />
12.70 9.56 4.31<br />
13.93 9.90 4.32<br />
14.75 10.18 4.42<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 12.46 3.03 12.94 12.06 3.16 12.15 11.57 4.24 11.78 11.18 4.74 11.27 10.84 5.20 10.96 10.46 5.09<br />
16.0 22.0 14.36 12.63 4.10 13.77 12.25 4.14 12.98 11.80 5.01 12.60 11.42 5.38 12.09 11.10 5.60 11.78 10.73 5.33<br />
18.0 25.0 15.20 12.74 4.44 14.60 12.38 4.46 13.80 11.96 5.25 13.42 11.59 5.48 12.91 11.30 5.68 12.60 10.95 5.32<br />
19.0 27.0 15.61 12.85 4.49 15.02 12.50 4.53 14.21 12.09 5.31 13.80 11.70 5.48 13.32 11.45 5.70 13.01 11.10 5.31<br />
22.0 30.0 16.86 13.11 4.49 16.26 12.78 4.60 15.45 12.42 5.44 15.07 12.06 5.74 14.55 11.81 5.79 14.24 11.47 5.37<br />
24.0 32.0 17.70 13.35 4.46 17.09 13.04 4.64 16.28 12.69 5.54 15.89 12.35 5.86 15.37 12.11 5.91 15.06 11.78 5.48<br />
TC SHC PI<br />
10.65 10.14 4.57<br />
11.47 10.42 4.63<br />
12.29 10.65 4.52<br />
12.70 10.80 4.48<br />
13.93 11.19 4.48<br />
14.75 11.50 4.59<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 189
Capacity tables 5CSL0-06B<br />
Models : AUUW426D +ATNH42GMLED , UVNH426LLAD, ABNH426RLAD<br />
[UU42W U3D]+ [UT42 NMD], [UV42 NLD] , [UB42 NRD]<br />
• Heating Capacity<br />
Model ATNH42GMLED[UT42 NMD]<br />
AFR 30<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 6.21 11.70 6.33 13.07 6.01 14.37 5.61 15.66 5.29 16.68 5.16 17.12 4.90<br />
18 10.86 6.31 11.68 6.48 13.09 6.19 14.36 5.77 15.55 5.43 16.47 5.26 17.07 4.96<br />
20 10.78 6.42 11.68 6.64 13.09 6.36 14.32 5.92 15.40 5.53 16.36 5.34 17.09 4.98<br />
21 10.75 6.48 11.68 6.74 13.09 6.45 14.29 6.00 15.30 5.59 16.36 5.38 16.99 4.99<br />
22 10.73 6.55 11.68 6.84 13.09 6.54 14.25 6.08 15.19 5.63 16.34 5.40 16.85 4.99<br />
24 10.63 6.66 11.56 6.93 12.93 6.63 14.17 6.13 15.17 5.67 16.07 5.42 16.75 5.01<br />
Model UVNH426LLAD[UV42 NLD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 6.39 11.70 6.51 13.07 6.18 14.37 5.77 15.66 5.44 16.68 5.31 17.12 5.04<br />
18 10.86 6.49 11.68 6.67 13.09 6.36 14.36 5.93 15.55 5.58 16.47 5.41 17.07 5.10<br />
20 10.78 6.60 11.68 6.83 13.09 6.55 14.32 6.09 15.40 5.69 16.36 5.49 17.09 5.12<br />
21 10.75 6.66 11.68 6.93 13.09 6.64 14.29 6.17 15.30 5.75 16.36 5.53 16.99 5.13<br />
22 10.73 6.74 11.68 7.03 13.09 6.73 14.25 6.25 15.19 5.79 16.34 5.56 16.85 5.13<br />
24 10.63 6.85 11.56 7.13 12.93 6.81 14.17 6.31 15.17 5.83 16.07 5.57 16.75 5.16<br />
Model ABNH426RLAD[UB42 NRD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 5.99 11.70 6.10 13.07 5.79 14.37 5.41 15.66 5.10 16.68 4.98 17.12 4.72<br />
18 10.86 6.08 11.68 6.25 13.09 5.96 14.36 5.56 15.55 5.23 16.47 5.07 17.07 4.78<br />
20 10.78 6.19 11.68 6.40 13.09 6.13 14.32 5.71 15.40 5.33 16.36 5.15 17.09 4.80<br />
21 10.75 6.24 11.68 6.49 13.09 6.22 14.29 5.78 15.30 5.39 16.36 5.18 16.99 4.81<br />
22 10.73 6.31 11.68 6.59 13.09 6.30 14.25 5.86 15.19 5.43 16.34 5.21 16.85 4.81<br />
24 10.63 6.42 11.56 6.68 12.93 6.39 14.17 5.91 15.17 5.46 16.07 5.22 16.75 4.83<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
190 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW486D +ATNH48GMLED , UVNH486LLAD, ABNH486RLAD<br />
[UU48W U3D]+ [UT48 NMD] , [UV48 NLD], [UB48 NRD]<br />
• Cooling Capacity<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.39 12.87 3.36 14.72 12.46 3.51 13.83 11.95 4.71 13.40 11.55 5.26 12.82 11.20 5.78 12.46 10.80 5.66<br />
16.0 22.0 16.34 13.04 4.56 15.67 12.65 4.60 14.76 12.18 5.56 14.34 11.79 5.97 13.75 11.47 6.22 13.40 11.08 5.92<br />
18.0 25.0 17.29 13.15 4.93 16.61 12.78 4.96 15.70 12.35 5.84 15.27 11.97 6.09 14.68 11.67 6.31 14.33 11.30 5.91<br />
19.0 27.0 17.76 13.27 4.98 17.08 12.91 5.03 16.17 12.49 5.90 15.70 12.09 6.09 15.15 11.83 6.33 14.80 11.46 5.90<br />
22.0 30.0 19.19 13.53 4.98 18.50 13.20 5.11 17.58 12.82 6.04 17.14 12.46 6.38 16.55 12.20 6.43 16.20 11.85 5.96<br />
24.0 32.0 20.13 13.79 4.95 19.44 13.47 5.16 18.52 13.11 6.15 18.07 12.75 6.51 17.49 12.51 6.57 17.13 12.16 6.09<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Model ABNH486RLAD[UB48 NRD]<br />
AFR 40<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 14.32 11.51 3.21 13.69 11.13 3.36 12.86 10.68 4.51 12.46 10.32 5.03 11.92 10.01 5.53 11.59 9.66 5.41<br />
16.0 22.0 15.20 11.66 4.36 14.57 11.31 4.40 13.73 10.89 5.32 13.33 10.54 5.71 12.79 10.25 5.95 12.46 9.91 5.67<br />
18.0 25.0 16.08 11.76 4.71 15.45 11.43 4.74 14.60 11.04 5.58 14.20 10.70 5.82 13.66 10.43 6.04 13.33 10.10 5.66<br />
19.0 27.0 16.52 11.86 4.77 15.89 11.54 4.81 15.04 11.16 5.65 14.60 10.80 5.82 14.09 10.57 6.05 13.76 10.24 5.65<br />
22.0 30.0 17.84 12.10 4.77 17.20 11.80 4.89 16.35 11.46 5.78 15.94 11.14 6.10 15.39 10.90 6.15 15.06 10.59 5.70<br />
24.0 32.0 18.72 12.32 4.74 18.08 12.04 4.94 17.22 11.72 5.89 16.81 11.40 6.23 16.26 11.18 6.28 15.93 10.87 5.83<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
12.11 10.47 5.08<br />
13.05 10.76 5.14<br />
13.98 10.99 5.02<br />
14.45 11.16 4.97<br />
15.85 11.56 4.97<br />
16.78 11.88 5.09<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
11.26 9.36 4.86<br />
12.13 9.62 4.92<br />
13.00 9.83 4.80<br />
13.43 9.97 4.76<br />
14.74 10.33 4.76<br />
15.60 10.62 4.87<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.10 13.59 3.39 14.44 13.15 3.54 13.56 12.62 4.76 13.15 12.19 5.31 12.57 11.82 5.83 12.23 11.41 5.71<br />
16.0 22.0 16.03 13.77 4.60 15.37 13.35 4.64 14.48 12.86 5.61 14.06 12.45 6.02 13.49 12.11 6.28 13.14 11.70 5.98<br />
18.0 25.0 16.96 13.89 4.97 16.29 13.50 5.00 15.40 13.04 5.89 14.98 12.64 6.14 14.40 12.32 6.37 14.06 11.93 5.97<br />
19.0 27.0 17.42 14.01 5.03 16.76 13.63 5.07 15.86 13.19 5.95 15.40 12.76 6.14 14.86 12.49 6.38 14.52 12.10 5.95<br />
22.0 30.0 18.82 14.29 5.03 18.14 13.94 5.16 17.24 13.54 6.09 16.81 13.15 6.43 16.24 12.88 6.48 15.89 12.51 6.01<br />
24.0 32.0 19.75 14.56 5.00 19.07 14.22 5.20 18.16 13.84 6.21 17.73 13.46 6.56 17.15 13.21 6.62 16.81 12.84 6.15<br />
TC SHC PI<br />
11.88 11.05 5.12<br />
12.80 11.36 5.19<br />
13.71 11.61 5.06<br />
14.17 11.78 5.02<br />
15.54 12.20 5.02<br />
16.46 12.54 5.14<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 191
Capacity tables 5CSL0-06B<br />
Models : AUUW486D +ATNH48GMLED , UVNH486LLAD, ABNH486RLAD<br />
[UU48W U3D]+ [UT48 NMD] , [UV48 NLD], [UB48 NRD]<br />
• Heating Capacity<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.52 7.29 13.37 7.42 14.94 7.05 16.43 6.58 17.90 6.21 19.06 6.06 19.57 5.75<br />
18 12.41 7.40 13.35 7.61 14.96 7.26 16.41 6.77 17.77 6.36 18.82 6.18 19.50 5.82<br />
20 12.32 7.53 13.35 7.79 14.96 7.47 16.37 6.95 17.60 6.49 18.69 6.26 19.54 5.84<br />
21 12.29 7.60 13.35 7.91 14.96 7.57 16.33 7.04 17.49 6.56 18.69 6.31 19.42 5.86<br />
22 12.27 7.68 13.35 8.02 14.96 7.67 16.29 7.13 17.36 6.60 18.67 6.34 19.25 5.86<br />
24 12.15 7.81 13.22 8.13 14.78 7.77 16.19 7.20 17.34 6.65 18.36 6.35 19.14 5.88<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.52 6.39 13.37 6.51 14.94 6.18 16.43 5.77 17.90 5.44 19.06 5.31 19.57 5.04<br />
18 12.41 6.49 13.35 6.67 14.96 6.36 16.41 5.93 17.77 5.58 18.82 5.41 19.50 5.10<br />
20 12.32 6.60 13.35 6.83 14.96 6.55 16.37 6.09 17.60 5.69 18.69 5.49 19.54 5.12<br />
21 12.29 6.66 13.35 6.93 14.96 6.64 16.33 6.17 17.49 5.75 18.69 5.53 19.42 5.13<br />
22 12.27 6.74 13.35 7.03 14.96 6.73 16.29 6.25 17.36 5.79 18.67 5.56 19.25 5.13<br />
24 12.15 6.85 13.22 7.13 14.78 6.81 16.19 6.31 17.34 5.83 18.36 5.57 19.14 5.16<br />
Model ABNH486RLAD[UB48 NRD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.95 7.29 13.82 7.42 15.45 7.05 16.99 6.58 18.51 6.21 19.71 6.06 20.24 5.75<br />
18 12.83 7.40 13.80 7.61 15.47 7.26 16.97 6.77 18.38 6.36 19.46 6.18 20.17 5.82<br />
20 12.74 7.53 13.80 7.79 15.47 7.47 16.93 6.95 18.20 6.49 19.33 6.26 20.20 5.84<br />
21 12.71 7.60 13.80 7.91 15.47 7.57 16.89 7.04 18.08 6.56 19.33 6.31 20.08 5.86<br />
22 12.68 7.68 13.80 8.02 15.47 7.67 16.84 7.13 17.95 6.60 19.31 6.34 19.91 5.86<br />
24 12.56 7.81 13.67 8.13 15.28 7.77 16.75 7.20 17.93 6.65 18.99 6.35 19.80 5.88<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
192 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW606D +ATNH60GMLED , UVNH606LLAD, ABNH606RLAD<br />
[UU60W U3D]+ [UT60 NMD], [UV60 NLD], [UB60 NRD]<br />
• Cooling Capacity<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.98 12.84 3.94 15.29 12.43 4.11 14.35 11.93 5.52 13.92 11.52 6.16 13.31 11.17 6.77 12.94 10.78 6.63<br />
16.0 22.0 16.97 13.01 5.34 16.27 12.62 5.38 15.33 12.15 6.51 14.89 11.76 7.00 14.28 11.44 7.29 13.91 11.06 6.94<br />
18.0 25.0 17.95 13.12 5.77 17.25 12.76 5.81 16.30 12.32 6.84 15.86 11.95 7.13 15.25 11.65 7.39 14.88 11.28 6.93<br />
19.0 27.0 18.44 13.24 5.84 17.74 12.88 5.89 16.79 12.46 6.91 16.30 12.06 7.13 15.73 11.80 7.41 15.36 11.43 6.91<br />
22.0 30.0 19.92 13.50 5.84 19.20 13.17 5.99 18.25 12.79 7.08 17.79 12.43 7.47 17.18 12.17 7.53 16.82 11.82 6.98<br />
24.0 32.0 20.90 13.75 5.80 20.18 13.43 6.04 19.23 13.08 7.21 18.76 12.72 7.62 18.15 12.48 7.69 17.79 12.13 7.14<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.39 11.96 3.86 14.72 11.57 4.04 13.83 11.11 5.42 13.40 10.73 6.05 12.82 10.41 6.64 12.46 10.04 6.51<br />
16.0 22.0 16.34 12.12 5.24 15.67 11.75 5.29 14.76 11.32 6.39 14.34 10.96 6.87 13.75 10.65 7.16 13.40 10.30 6.81<br />
18.0 25.0 17.29 12.22 5.66 16.61 11.88 5.70 15.70 11.48 6.71 15.27 11.13 7.00 14.68 10.85 7.26 14.33 10.50 6.80<br />
19.0 27.0 17.76 12.33 5.73 17.08 12.00 5.78 16.17 11.61 6.79 15.70 11.23 7.00 15.15 10.99 7.28 14.80 10.65 6.79<br />
22.0 30.0 19.19 12.58 5.73 18.50 12.27 5.88 17.58 11.91 6.95 17.14 11.58 7.33 16.55 11.34 7.39 16.20 11.01 6.85<br />
24.0 32.0 20.13 12.81 5.70 19.44 12.51 5.93 18.52 12.18 7.07 18.07 11.85 7.48 17.49 11.62 7.55 17.13 11.30 7.00<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
12.57 10.44 5.95<br />
13.54 10.74 6.02<br />
14.51 10.97 5.88<br />
15.00 11.13 5.82<br />
16.45 11.53 5.83<br />
17.42 11.85 5.97<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
12.11 9.73 5.84<br />
13.05 10.00 5.91<br />
13.98 10.22 5.77<br />
14.45 10.37 5.72<br />
15.85 10.74 5.72<br />
16.78 11.04 5.86<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.98 14.43 3.83 15.29 13.96 4.01 14.35 13.40 5.38 13.92 12.95 6.00 13.31 12.55 6.59 12.94 12.11 6.46<br />
16.0 22.0 16.97 14.62 5.20 16.27 14.18 5.25 15.33 13.66 6.34 14.89 13.22 6.81 14.28 12.85 7.10 13.91 12.42 6.76<br />
18.0 25.0 17.95 14.74 5.62 17.25 14.33 5.65 16.30 13.85 6.66 15.86 13.42 6.94 15.25 13.08 7.20 14.88 12.67 6.75<br />
19.0 27.0 18.44 14.87 5.69 17.74 14.47 5.74 16.79 14.00 6.73 16.30 13.55 6.94 15.73 13.26 7.22 15.36 12.85 6.73<br />
22.0 30.0 19.92 15.17 5.69 19.20 14.80 5.84 18.25 14.37 6.89 17.79 13.97 7.28 17.18 13.68 7.34 16.82 13.28 6.80<br />
24.0 32.0 20.90 15.45 5.65 20.18 15.09 5.89 19.23 14.70 7.02 18.76 14.29 7.42 18.15 14.02 7.49 17.79 13.63 6.95<br />
TC SHC PI<br />
12.57 11.73 5.79<br />
13.54 12.06 5.87<br />
14.51 12.32 5.73<br />
15.00 12.50 5.67<br />
16.45 12.95 5.68<br />
17.42 13.31 5.81<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 193
Capacity tables 5CSL0-06B<br />
Models : AUUW606D +ATNH60GMLED , UVNH606LLAD, ABNH606RLAD<br />
[UU60W U3D]+ [UT60 NMD], [UV60 NLD], [UB60 NRD]<br />
• Heating Capacity<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 8.83 14.20 8.99 15.87 8.54 17.45 7.98 19.01 7.52 20.25 7.34 20.79 6.97<br />
18 13.18 8.96 14.18 9.22 15.90 8.79 17.44 8.20 18.88 7.71 20.00 7.48 20.72 7.05<br />
20 13.09 9.12 14.18 9.44 15.90 9.04 17.39 8.42 18.70 7.87 19.86 7.59 20.76 7.08<br />
21 13.06 9.20 14.18 9.58 15.90 9.17 17.35 8.53 18.58 7.94 19.86 7.64 20.63 7.09<br />
22 13.03 9.31 14.18 9.72 15.90 9.30 17.30 8.63 18.45 8.00 19.84 7.68 20.46 7.09<br />
24 12.91 9.47 14.04 9.85 15.70 9.42 17.21 8.72 18.42 8.06 19.51 7.70 20.34 7.13<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 8.83 14.20 8.99 15.87 8.54 17.45 7.98 19.01 7.52 20.25 7.34 20.79 6.97<br />
18 13.18 8.96 14.18 9.22 15.90 8.79 17.44 8.20 18.88 7.71 20.00 7.48 20.72 7.05<br />
20 13.09 9.12 14.18 9.44 15.90 9.04 17.39 8.42 18.70 7.87 19.86 7.59 20.76 7.08<br />
21 13.06 9.20 14.18 9.58 15.90 9.17 17.35 8.53 18.58 7.94 19.86 7.64 20.63 7.09<br />
22 13.03 9.31 14.18 9.72 15.90 9.30 17.30 8.63 18.45 8.00 19.84 7.68 20.46 7.09<br />
24 12.91 9.47 14.04 9.85 15.70 9.42 17.21 8.72 18.42 8.06 19.51 7.70 20.34 7.13<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 7.34 14.20 7.47 15.87 7.10 17.45 6.63 19.01 6.25 20.25 6.10 20.79 5.79<br />
18 13.18 7.45 14.18 7.66 15.90 7.31 17.44 6.81 18.88 6.41 20.00 6.22 20.72 5.85<br />
20 13.09 7.58 14.18 7.84 15.90 7.52 17.39 6.99 18.70 6.54 19.86 6.31 20.76 5.88<br />
21 13.06 7.65 14.18 7.96 15.90 7.62 17.35 7.08 18.58 6.60 19.86 6.35 20.63 5.89<br />
22 13.03 7.74 14.18 8.07 15.90 7.72 17.30 7.17 18.45 6.65 19.84 6.38 20.46 5.89<br />
24 12.91 7.87 14.04 8.18 15.70 7.83 17.21 7.24 18.42 6.69 19.51 6.40 20.34 5.92<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
194 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW368D+ATNH36GNLED, UVNH366KLAD, ABNH366GLAD<br />
[UU37W UED]+[UT36 NND], [UV36 NKD], [UB36 NGD]<br />
• Cooling Capacity<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.79 9.49 2.27 10.32 9.18 2.38 9.69 8.81 3.19 9.39 8.52 3.56 8.98 8.26 3.91 8.73 7.97 3.83<br />
16.0 22.0 11.45 9.61 3.08 10.98 9.33 3.11 10.34 8.98 3.76 10.05 8.69 4.04 9.63 8.45 4.21 9.39 8.17 4.01<br />
18.0 25.0 12.11 9.70 3.33 11.64 9.43 3.35 11.00 9.11 3.95 10.70 8.83 4.12 10.29 8.61 4.27 10.04 8.33 4.00<br />
19.0 27.0 12.45 9.78 3.37 11.97 9.52 3.40 11.33 9.21 3.99 11.00 8.91 4.12 10.62 8.72 4.28 10.37 8.45 3.99<br />
22.0 30.0 13.44 9.98 3.37 12.96 9.73 3.46 12.32 9.45 4.09 12.01 9.19 4.32 11.60 8.99 4.35 11.35 8.73 4.03<br />
24.0 32.0 14.11 10.16 3.35 13.62 9.93 3.49 12.97 9.67 4.16 12.66 9.40 4.40 12.25 9.22 4.44 12.00 8.97 4.12<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Indoor Air<br />
Temperature<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.30 8.50 2.42 9.85 8.22 2.53 9.25 7.89 3.40 8.96 7.63 3.79 8.57 7.39 4.16 8.34 7.13 4.08<br />
16.0 22.0 10.93 8.61 3.28 10.48 8.35 3.31 9.87 8.04 4.00 9.59 7.79 4.30 9.20 7.57 4.48 8.96 7.32 4.27<br />
18.0 25.0 11.56 8.69 3.55 11.11 8.44 3.57 10.50 8.16 4.20 10.21 7.91 4.38 9.82 7.71 4.55 9.58 7.46 4.26<br />
19.0 27.0 11.88 8.76 3.59 11.42 8.52 3.62 10.82 8.25 4.25 10.50 7.98 4.38 10.13 7.81 4.56 9.90 7.57 4.25<br />
22.0 30.0 12.83 8.94 3.59 12.37 8.72 3.68 11.76 8.47 4.35 11.46 8.23 4.59 11.07 8.06 4.63 10.83 7.82 4.29<br />
24.0 32.0 13.46 9.10 3.57 13.00 8.89 3.72 12.38 8.66 4.43 12.09 8.42 4.69 11.69 8.26 4.73 11.46 8.03 4.39<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
8.49 7.72 3.44<br />
9.14 7.93 3.48<br />
9.79 8.11 3.40<br />
10.12 8.22 3.37<br />
11.10 8.52 3.37<br />
11.76 8.76 3.45<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.79 9.26 2.56 10.32 8.96 2.67 9.69 8.60 3.59 9.39 8.30 4.01 8.98 8.05 4.40 8.73 7.77 4.31<br />
16.0 22.0 11.45 9.38 3.47 10.98 9.10 3.50 10.34 8.76 4.23 10.05 8.48 4.55 9.63 8.24 4.74 9.39 7.97 4.51<br />
18.0 25.0 12.11 9.46 3.75 11.64 9.19 3.77 11.00 8.88 4.44 10.70 8.61 4.63 10.29 8.39 4.81 10.04 8.13 4.50<br />
19.0 27.0 12.45 9.54 3.79 11.97 9.28 3.83 11.33 8.98 4.49 11.00 8.69 4.63 10.62 8.50 4.82 10.37 8.24 4.49<br />
22.0 30.0 13.44 9.73 3.79 12.96 9.49 3.89 12.32 9.22 4.60 12.01 8.96 4.86 11.60 8.77 4.89 11.35 8.52 4.54<br />
24.0 32.0 14.11 9.91 3.77 13.62 9.68 3.93 12.97 9.43 4.69 12.66 9.17 4.95 12.25 9.00 5.00 12.00 8.74 4.64<br />
TC SHC PI<br />
8.10 6.91 3.66<br />
8.72 7.11 3.70<br />
9.35 7.26 3.62<br />
9.66 7.37 3.58<br />
10.60 7.63 3.58<br />
11.22 7.84 3.67<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
8.49 7.53 3.87<br />
9.14 7.74 3.91<br />
9.79 7.90 3.82<br />
10.12 8.02 3.79<br />
11.10 8.31 3.79<br />
11.76 8.54 3.88<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 195
Capacity tables 5CSL0-06B<br />
Models : AUUW368D+ATNH36GNLED, UVNH366KLAD, ABNH366GLAD<br />
[UU37W UED]+[UT36 NND], [UV36 NKD], [UB36 NGD]<br />
• Heating Capacity<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Indoor Air<br />
Temperature<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.61 5.19 9.19 5.28 10.27 5.02 11.29 4.68 12.30 4.41 13.10 4.31 13.45 4.09<br />
18 8.53 5.26 9.18 5.41 10.29 5.16 11.28 4.81 12.22 4.53 12.94 4.39 13.41 4.14<br />
20 8.47 5.36 9.18 5.54 10.29 5.31 11.25 4.94 12.10 4.62 12.85 4.46 13.43 4.16<br />
21 8.45 5.40 9.18 5.62 10.29 5.39 11.23 5.01 12.02 4.66 12.85 4.49 13.35 4.17<br />
22 8.43 5.47 9.18 5.71 10.29 5.46 11.20 5.07 11.94 4.70 12.84 4.51 13.24 4.17<br />
24 8.35 5.56 9.09 5.78 10.16 5.53 11.13 5.12 11.92 4.73 12.62 4.52 13.16 4.19<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.25 5.25 8.81 5.35 9.85 5.08 10.83 4.74 11.79 4.47 12.56 4.36 12.90 4.14<br />
18 8.18 5.33 8.80 5.48 9.86 5.23 10.82 4.87 11.71 4.58 12.40 4.45 12.85 4.19<br />
20 8.12 5.42 8.80 5.61 9.86 5.38 10.79 5.00 11.60 4.68 12.32 4.51 12.88 4.21<br />
21 8.10 5.47 8.80 5.69 9.86 5.45 10.77 5.07 11.53 4.72 12.32 4.54 12.80 4.22<br />
22 8.08 5.53 8.80 5.78 9.86 5.53 10.73 5.13 11.44 4.76 12.31 4.57 12.69 4.22<br />
24 8.01 5.63 8.71 5.86 9.74 5.60 10.67 5.18 11.43 4.79 12.10 4.58 12.62 4.24<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 8.75 5.60 9.34 5.71 10.44 5.42 11.48 5.06 12.51 4.77 13.32 4.66 13.68 4.42<br />
18 8.67 5.69 9.33 5.85 10.46 5.58 11.47 5.20 12.42 4.89 13.15 4.75 13.63 4.47<br />
20 8.61 5.79 9.33 5.99 10.46 5.74 11.44 5.34 12.30 4.99 13.06 4.82 13.65 4.49<br />
21 8.59 5.84 9.33 6.08 10.46 5.82 11.41 5.41 12.22 5.04 13.06 4.85 13.57 4.50<br />
22 8.57 5.91 9.33 6.16 10.46 5.90 11.38 5.48 12.13 5.08 13.05 4.87 13.46 4.50<br />
24 8.49 6.01 9.24 6.25 10.33 5.98 11.32 5.53 12.12 5.11 12.83 4.88 13.38 4.52<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
196 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW428D +ATNH42GMLED , UVNH426LLAD , ABNH426RLAD<br />
[UU43W U3D]+ [UT42 NMD] , [UV42 NLD] , [UB42 NRD]<br />
• Cooling Capacity<br />
Model ATNH42GMLED[UT42 NMD]<br />
AFR 30<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 11.70 2.84 12.94 11.32 2.96 12.15 10.86 3.98 11.78 10.50 4.44 11.27 10.18 4.87 10.96 9.82 4.78<br />
16.0 22.0 14.36 11.85 3.85 13.77 11.50 3.88 12.98 11.07 4.69 12.60 10.72 5.04 12.09 10.42 5.25 11.78 10.07 5.00<br />
18.0 25.0 15.20 11.96 4.16 14.60 11.62 4.18 13.80 11.23 4.93 13.42 10.88 5.13 12.91 10.61 5.33 12.60 10.27 4.99<br />
19.0 27.0 15.61 12.06 4.21 15.02 11.73 4.24 14.21 11.35 4.98 13.80 10.98 5.13 13.32 10.75 5.34 13.01 10.42 4.98<br />
22.0 30.0 16.86 12.30 4.20 16.26 12.00 4.32 15.45 11.65 5.10 15.07 11.32 5.38 14.55 11.09 5.42 14.24 10.77 5.03<br />
24.0 32.0 17.70 12.53 4.18 17.09 12.24 4.35 16.28 11.92 5.19 15.89 11.59 5.49 15.37 11.37 5.54 15.06 11.05 5.14<br />
Model UVNH426LLAD[UV42 NLD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Model ABNH426RLAD[UB42 NRD]<br />
AFR 36<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 11.03 2.92 12.94 10.67 3.05 12.15 10.24 4.09 11.78 9.90 4.56 11.27 9.60 5.01 10.96 9.26 4.91<br />
16.0 22.0 14.36 11.17 3.95 13.77 10.84 3.99 12.98 10.44 4.82 12.60 10.10 5.18 12.09 9.82 5.40 11.78 9.50 5.14<br />
18.0 25.0 15.20 11.27 4.28 14.60 10.95 4.30 13.80 10.58 5.07 13.42 10.26 5.28 12.91 10.00 5.48 12.60 9.69 5.13<br />
19.0 27.0 15.61 11.37 4.32 15.02 11.06 4.36 14.21 10.70 5.12 13.80 10.36 5.28 13.32 10.13 5.49 13.01 9.82 5.12<br />
22.0 30.0 16.86 11.60 4.32 16.26 11.31 4.44 15.45 10.99 5.24 15.07 10.68 5.53 14.55 10.45 5.58 14.24 10.15 5.17<br />
24.0 32.0 17.70 11.81 4.30 17.09 11.54 4.48 16.28 11.23 5.34 15.89 10.93 5.65 15.37 10.72 5.70 15.06 10.42 5.29<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
10.65 9.52 4.29<br />
11.47 9.78 4.34<br />
12.29 9.99 4.24<br />
12.70 10.14 4.20<br />
13.93 10.50 4.20<br />
14.75 10.80 4.30<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 13.53 12.46 3.03 12.94 12.06 3.16 12.15 11.57 4.24 11.78 11.18 4.74 11.27 10.84 5.20 10.96 10.46 5.09<br />
16.0 22.0 14.36 12.63 4.10 13.77 12.25 4.14 12.98 11.80 5.01 12.60 11.42 5.38 12.09 11.10 5.60 11.78 10.73 5.33<br />
18.0 25.0 15.20 12.74 4.44 14.60 12.38 4.46 13.80 11.96 5.25 13.42 11.59 5.48 12.91 11.30 5.68 12.60 10.95 5.32<br />
19.0 27.0 15.61 12.85 4.49 15.02 12.50 4.53 14.21 12.09 5.31 13.80 11.70 5.48 13.32 11.45 5.70 13.01 11.10 5.31<br />
22.0 30.0 16.86 13.11 4.49 16.26 12.78 4.60 15.45 12.42 5.44 15.07 12.06 5.74 14.55 11.81 5.79 14.24 11.47 5.37<br />
24.0 32.0 17.70 13.35 4.46 17.09 13.04 4.64 16.28 12.69 5.54 15.89 12.35 5.86 15.37 12.11 5.91 15.06 11.78 5.48<br />
TC SHC PI<br />
10.65 8.97 4.41<br />
11.47 9.22 4.46<br />
12.29 9.42 4.36<br />
12.70 9.56 4.31<br />
13.93 9.90 4.32<br />
14.75 10.18 4.42<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
10.65 10.14 4.57<br />
11.47 10.42 4.63<br />
12.29 10.65 4.52<br />
12.70 10.80 4.48<br />
13.93 11.19 4.48<br />
14.75 11.50 4.59<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 197
Capacity tables 5CSL0-06B<br />
Models : AUUW428D +ATNH42GMLED , UVNH426LLAD , ABNH426RLAD<br />
[UU43W U3D]+ [UT42 NMD] , [UV42 NLD] , [UB42 NRD]<br />
• Heating Capacity<br />
Model ATNH42GMLED[UT42 NMD]<br />
AFR 30<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 6.21 11.70 6.33 13.07 6.01 14.37 5.61 15.66 5.29 16.68 5.16 17.12 4.90<br />
18 10.86 6.31 11.68 6.48 13.09 6.19 14.36 5.77 15.55 5.43 16.47 5.26 17.07 4.96<br />
20 10.78 6.42 11.68 6.64 13.09 6.36 14.32 5.92 15.40 5.53 16.36 5.34 17.09 4.98<br />
21 10.75 6.48 11.68 6.74 13.09 6.45 14.29 6.00 15.30 5.59 16.36 5.38 16.99 4.99<br />
22 10.73 6.55 11.68 6.84 13.09 6.54 14.25 6.08 15.19 5.63 16.34 5.40 16.85 4.99<br />
24 10.63 6.66 11.56 6.93 12.93 6.63 14.17 6.13 15.17 5.67 16.07 5.42 16.75 5.01<br />
Model UVNH426LLAD[UV42 NLD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 6.39 11.70 6.51 13.07 6.18 14.37 5.77 15.66 5.44 16.68 5.31 17.12 5.04<br />
18 10.86 6.49 11.68 6.67 13.09 6.36 14.36 5.93 15.55 5.58 16.47 5.41 17.07 5.10<br />
20 10.78 6.60 11.68 6.83 13.09 6.55 14.32 6.09 15.40 5.69 16.36 5.49 17.09 5.12<br />
21 10.75 6.66 11.68 6.93 13.09 6.64 14.29 6.17 15.30 5.75 16.36 5.53 16.99 5.13<br />
22 10.73 6.74 11.68 7.03 13.09 6.73 14.25 6.25 15.19 5.79 16.34 5.56 16.85 5.13<br />
24 10.63 6.85 11.56 7.13 12.93 6.81 14.17 6.31 15.17 5.83 16.07 5.57 16.75 5.16<br />
Model ABNH426RLAD[UB42 NRD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 10.96 6.13 11.70 6.25 13.07 5.93 14.37 5.54 15.66 5.22 16.68 5.10 17.12 4.84<br />
18 10.86 6.23 11.68 6.40 13.09 6.11 14.36 5.69 15.55 5.36 16.47 5.20 17.07 4.89<br />
20 10.78 6.34 11.68 6.56 13.09 6.28 14.32 5.84 15.40 5.46 16.36 5.27 17.09 4.92<br />
21 10.75 6.39 11.68 6.65 13.09 6.37 14.29 5.92 15.30 5.52 16.36 5.31 16.99 4.93<br />
22 10.73 6.47 11.68 6.75 13.09 6.46 14.25 6.00 15.19 5.56 16.34 5.33 16.85 4.93<br />
24 10.63 6.57 11.56 6.84 12.93 6.54 14.17 6.06 15.17 5.60 16.07 5.35 16.75 4.95<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
198 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW488D +ATNH48GMLED , UVNH486LLAD , ABNH486RLAD<br />
[UU49W U3D]+ [UT48 NMD] , [ UV48 NLD] , [UB48 NRD]<br />
• Cooling Capacity<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.39 12.85 3.34 14.72 12.43 3.49 13.83 11.93 4.68 13.40 11.53 5.23 12.82 11.17 5.74 12.46 10.78 5.62<br />
16.0 22.0 16.34 13.01 4.53 15.67 12.62 4.57 14.76 12.16 5.52 14.34 11.77 5.93 13.75 11.44 6.18 13.40 11.06 5.89<br />
18.0 25.0 17.29 13.13 4.90 16.61 12.76 4.92 15.70 12.33 5.80 15.27 11.95 6.05 14.68 11.65 6.27 14.33 11.28 5.88<br />
19.0 27.0 17.76 13.24 4.95 17.08 12.88 5.00 16.17 12.46 5.86 15.70 12.06 6.05 15.15 11.80 6.29 14.80 11.44 5.86<br />
22.0 30.0 19.19 13.51 4.95 18.50 13.17 5.08 17.58 12.79 6.00 17.14 12.43 6.34 16.55 12.17 6.39 16.20 11.82 5.92<br />
24.0 32.0 20.13 13.76 4.92 19.44 13.44 5.13 18.52 13.08 6.11 18.07 12.72 6.46 17.49 12.48 6.52 17.13 12.14 6.05<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 40<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 14.32 11.44 3.21 13.69 11.07 3.36 12.86 10.62 4.51 12.46 10.26 5.03 11.92 9.95 5.53 11.59 9.60 5.41<br />
16.0 22.0 15.20 11.59 4.36 14.57 11.24 4.40 13.73 10.82 5.32 13.33 10.47 5.71 12.79 10.19 5.95 12.46 9.85 5.67<br />
18.0 25.0 16.08 11.69 4.71 15.45 11.36 4.74 14.60 10.97 5.58 14.20 10.64 5.82 13.66 10.37 6.04 13.33 10.04 5.66<br />
19.0 27.0 16.52 11.79 4.77 15.89 11.47 4.81 15.04 11.10 5.65 14.60 10.74 5.82 14.09 10.51 6.05 13.76 10.18 5.65<br />
22.0 30.0 17.84 12.02 4.77 17.20 11.73 4.89 16.35 11.39 5.78 15.94 11.07 6.10 15.39 10.84 6.15 15.06 10.52 5.70<br />
24.0 32.0 18.72 12.25 4.74 18.08 11.96 4.94 17.22 11.65 5.89 16.81 11.33 6.23 16.26 11.11 6.28 15.93 10.80 5.83<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
12.11 10.45 5.05<br />
13.05 10.74 5.11<br />
13.98 10.97 4.99<br />
14.45 11.13 4.94<br />
15.85 11.53 4.94<br />
16.78 11.85 5.06<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.10 13.59 3.39 14.44 13.15 3.54 13.56 12.62 4.76 13.15 12.19 5.31 12.57 11.82 5.83 12.23 11.41 5.71<br />
16.0 22.0 16.03 13.77 4.60 15.37 13.35 4.64 14.48 12.86 5.61 14.06 12.45 6.02 13.49 12.11 6.28 13.14 11.70 5.98<br />
18.0 25.0 16.96 13.89 4.97 16.29 13.50 5.00 15.40 13.04 5.89 14.98 12.64 6.14 14.40 12.32 6.37 14.06 11.93 5.97<br />
19.0 27.0 17.42 14.01 5.03 16.76 13.63 5.07 15.86 13.19 5.95 15.40 12.76 6.14 14.86 12.49 6.38 14.52 12.10 5.95<br />
22.0 30.0 18.82 14.29 5.03 18.14 13.94 5.16 17.24 13.54 6.09 16.81 13.15 6.43 16.24 12.88 6.48 15.89 12.51 6.01<br />
24.0 32.0 19.75 14.56 5.00 19.07 14.22 5.20 18.16 13.84 6.21 17.73 13.46 6.56 17.15 13.21 6.62 16.81 12.84 6.15<br />
TC SHC PI<br />
11.26 9.30 4.86<br />
12.13 9.56 4.92<br />
13.00 9.77 4.80<br />
13.43 9.91 4.76<br />
14.74 10.27 4.76<br />
15.60 10.55 4.87<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
11.88 11.05 5.12<br />
12.80 11.36 5.19<br />
13.71 11.61 5.06<br />
14.17 11.78 5.02<br />
15.54 12.20 5.02<br />
16.46 12.54 5.14<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 199
Capacity tables 5CSL0-06B<br />
Models : AUUW488D +ATNH48GMLED , UVNH486LLAD , ABNH486RLAD<br />
[UU49W U3D]+ [UT48 NMD] , [ UV48 NLD] , [UB48 NRD]<br />
• Heating Capacity<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.52 7.48 13.37 7.62 14.94 7.24 16.43 6.76 17.90 6.37 19.06 6.22 19.57 5.90<br />
18 12.41 7.59 13.35 7.81 14.96 7.45 16.41 6.94 17.77 6.53 18.82 6.34 19.50 5.97<br />
20 12.32 7.73 13.35 8.00 14.96 7.66 16.37 7.13 17.60 6.66 18.69 6.43 19.54 6.00<br />
21 12.29 7.80 13.35 8.11 14.96 7.77 16.33 7.22 17.49 6.73 18.69 6.48 19.42 6.01<br />
22 12.27 7.89 13.35 8.23 14.96 7.88 16.29 7.32 17.36 6.78 18.67 6.51 19.25 6.01<br />
24 12.15 8.02 13.22 8.34 14.78 7.98 16.19 7.39 17.34 6.83 18.36 6.52 19.14 6.04<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.52 7.64 13.37 7.78 14.94 7.39 16.43 6.90 17.90 6.51 19.06 6.35 19.57 6.03<br />
18 12.41 7.76 13.35 7.98 14.96 7.61 16.41 7.09 17.77 6.67 18.82 6.47 19.50 6.10<br />
20 12.32 7.90 13.35 8.17 14.96 7.83 16.37 7.28 17.60 6.81 18.69 6.57 19.54 6.13<br />
21 12.29 7.96 13.35 8.29 14.96 7.94 16.33 7.38 17.49 6.87 18.69 6.62 19.42 6.14<br />
22 12.27 8.06 13.35 8.41 14.96 8.05 16.29 7.47 17.36 6.92 18.67 6.65 19.25 6.14<br />
24 12.15 8.19 13.22 8.52 14.78 8.15 16.19 7.55 17.34 6.97 18.36 6.66 19.14 6.17<br />
Model ABNH486RLAD[UB48 NRD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.95 7.34 13.82 7.47 15.45 7.10 16.99 6.63 18.51 6.25 19.71 6.10 20.24 5.79<br />
18 12.83 7.45 13.80 7.66 15.47 7.31 16.97 6.81 18.38 6.41 19.46 6.22 20.17 5.85<br />
20 12.74 7.58 13.80 7.84 15.47 7.52 16.93 6.99 18.20 6.54 19.33 6.31 20.20 5.88<br />
21 12.71 7.65 13.80 7.96 15.47 7.62 16.89 7.08 18.08 6.60 19.33 6.35 20.08 5.89<br />
22 12.68 7.74 13.80 8.07 15.47 7.72 16.84 7.17 17.95 6.65 19.31 6.38 19.91 5.89<br />
24 12.56 7.87 13.67 8.18 15.28 7.83 16.75 7.24 17.93 6.69 18.99 6.40 19.80 5.92<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
200 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW608D +ATNH60GMLED , UVNH606LLAD , ABNH606RLAD<br />
[UU61W U3D] + [UT60 NMD], [UV60 NLD] , [UB60 NRD]<br />
• Cooling Capacity<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.98 12.76 4.10 15.29 12.34 4.29 14.35 11.84 5.76 13.92 11.44 6.42 13.31 11.10 7.06 12.94 10.71 6.91<br />
16.0 22.0 16.97 12.92 5.57 16.27 12.53 5.61 15.33 12.07 6.79 14.89 11.68 7.29 14.28 11.36 7.60 13.91 10.98 7.23<br />
18.0 25.0 17.95 13.03 6.02 17.25 12.67 6.05 16.30 12.24 7.13 15.86 11.86 7.43 15.25 11.57 7.71 14.88 11.20 7.22<br />
19.0 27.0 18.44 13.15 6.09 17.74 12.79 6.14 16.79 12.38 7.21 16.30 11.98 7.43 15.73 11.72 7.73 15.36 11.36 7.21<br />
22.0 30.0 19.92 13.41 6.09 19.20 13.08 6.25 18.25 12.71 7.38 17.79 12.35 7.79 17.18 12.09 7.85 16.82 11.74 7.28<br />
24.0 32.0 20.90 13.66 6.05 20.18 13.34 6.30 19.23 12.99 7.52 18.76 12.64 7.95 18.15 12.40 8.02 17.79 12.05 7.44<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 38<br />
Indoor Air<br />
Temperature<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.39 11.96 3.86 14.72 11.57 4.04 13.83 11.11 5.42 13.40 10.73 6.05 12.82 10.41 6.64 12.46 10.04 6.51<br />
16.0 22.0 16.34 12.12 5.24 15.67 11.75 5.29 14.76 11.32 6.39 14.34 10.96 6.87 13.75 10.65 7.16 13.40 10.30 6.81<br />
18.0 25.0 17.29 12.22 5.66 16.61 11.88 5.70 15.70 11.48 6.71 15.27 11.13 7.00 14.68 10.85 7.26 14.33 10.50 6.80<br />
19.0 27.0 17.76 12.33 5.73 17.08 12.00 5.78 16.17 11.61 6.79 15.70 11.23 7.00 15.15 10.99 7.28 14.80 10.65 6.79<br />
22.0 30.0 19.19 12.58 5.73 18.50 12.27 5.88 17.58 11.91 6.95 17.14 11.58 7.33 16.55 11.34 7.39 16.20 11.01 6.85<br />
24.0 32.0 20.13 12.81 5.70 19.44 12.51 5.93 18.52 12.18 7.07 18.07 11.85 7.48 17.49 11.62 7.55 17.13 11.30 7.00<br />
Indoor Air<br />
Temperature<br />
TC SHC PI<br />
12.57 10.37 6.20<br />
13.54 10.66 6.28<br />
14.51 10.89 6.13<br />
15.00 11.05 6.07<br />
16.45 11.45 6.08<br />
17.42 11.77 6.22<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 15.98 14.43 3.83 15.29 13.96 4.01 14.35 13.40 5.38 13.92 12.95 6.00 13.31 12.55 6.59 12.94 12.11 6.46<br />
16.0 22.0 16.97 14.62 5.20 16.27 14.18 5.25 15.33 13.66 6.34 14.89 13.22 6.81 14.28 12.85 7.10 13.91 12.42 6.76<br />
18.0 25.0 17.95 14.74 5.62 17.25 14.33 5.65 16.30 13.85 6.66 15.86 13.42 6.94 15.25 13.08 7.20 14.88 12.67 6.75<br />
19.0 27.0 18.44 14.87 5.69 17.74 14.47 5.74 16.79 14.00 6.73 16.30 13.55 6.94 15.73 13.26 7.22 15.36 12.85 6.73<br />
22.0 30.0 19.92 15.17 5.69 19.20 14.80 5.84 18.25 14.37 6.89 17.79 13.97 7.28 17.18 13.68 7.34 16.82 13.28 6.80<br />
24.0 32.0 20.90 15.45 5.65 20.18 15.09 5.89 19.23 14.70 7.02 18.76 14.29 7.42 18.15 14.02 7.49 17.79 13.63 6.95<br />
TC SHC PI<br />
12.11 9.73 5.84<br />
13.05 10.00 5.91<br />
13.98 10.22 5.77<br />
14.45 10.37 5.72<br />
15.85 10.74 5.72<br />
16.78 11.04 5.86<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
TC SHC PI<br />
12.57 11.73 5.79<br />
13.54 12.06 5.87<br />
14.51 12.32 5.73<br />
15.00 12.50 5.67<br />
16.45 12.95 5.68<br />
17.42 13.31 5.81<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 201
Capacity tables 5CSL0-06B<br />
Models : AUUW608D +ATNH60GMLED , UVNH606LLAD , ABNH606RLAD<br />
[UU61W U3D] + [UT60 NMD], [UV60 NLD] , [UB60 NRD]<br />
• Heating Capacity<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 9.06 14.20 9.22 15.87 8.76 17.45 8.18 19.01 7.71 20.25 7.52 20.79 7.14<br />
18 13.18 9.19 14.18 9.45 15.90 9.02 17.44 8.41 18.88 7.91 20.00 7.67 20.72 7.23<br />
20 13.09 9.36 14.18 9.68 15.90 9.27 17.39 8.63 18.70 8.07 19.86 7.78 20.76 7.26<br />
21 13.06 9.44 14.18 9.82 15.90 9.40 17.35 8.74 18.58 8.14 19.86 7.84 20.63 7.28<br />
22 13.03 9.55 14.18 9.96 15.90 9.53 17.30 8.85 18.45 8.20 19.84 7.88 20.46 7.28<br />
24 12.91 9.71 14.04 10.10 15.70 9.66 17.21 8.94 18.42 8.26 19.51 7.89 20.34 7.31<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 38<br />
Indoor Air<br />
Temperature<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 8.83 14.20 8.99 15.87 8.54 17.45 7.98 19.01 7.52 20.25 7.34 20.79 6.97<br />
18 13.18 8.96 14.18 9.22 15.90 8.79 17.44 8.20 18.88 7.71 20.00 7.48 20.72 7.05<br />
20 13.09 9.12 14.18 9.44 15.90 9.04 17.39 8.42 18.70 7.87 19.86 7.59 20.76 7.08<br />
21 13.06 9.20 14.18 9.58 15.90 9.17 17.35 8.53 18.58 7.94 19.86 7.64 20.63 7.09<br />
22 13.03 9.31 14.18 9.72 15.90 9.30 17.30 8.63 18.45 8.00 19.84 7.68 20.46 7.09<br />
24 12.91 9.47 14.04 9.85 15.70 9.42 17.21 8.72 18.42 8.06 19.51 7.70 20.34 7.13<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 13.31 7.55 14.20 7.69 15.87 7.30 17.45 6.82 19.01 6.42 20.25 6.27 20.79 5.95<br />
18 13.18 7.66 14.18 7.88 15.90 7.51 17.44 7.00 18.88 6.59 20.00 6.39 20.72 6.02<br />
20 13.09 7.80 14.18 8.07 15.90 7.73 17.39 7.19 18.70 6.72 19.86 6.49 20.76 6.05<br />
21 13.06 7.86 14.18 8.18 15.90 7.84 17.35 7.29 18.58 6.79 19.86 6.53 20.63 6.06<br />
22 13.03 7.96 14.18 8.30 15.90 7.94 17.30 7.38 18.45 6.84 19.84 6.56 20.46 6.06<br />
24 12.91 8.09 14.04 8.42 15.70 8.05 17.21 7.45 18.42 6.88 19.51 6.58 20.34 6.09<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
202 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW186DH + ATNH18GPLED<br />
[UU18WH UED] + [UT18 NPD]<br />
• Cooling Capacity<br />
Model ATNH18GPLED[UT18 NPD]<br />
AFR 17<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.39 5.04 0.98 5.16 4.87 1.03 4.84 4.68 1.38 4.70 4.52 1.54 4.49 4.38 1.69 4.37 4.23 1.66<br />
16.0 22.0 5.72 5.10 1.33 5.49 4.95 1.35 5.17 4.77 1.63 5.02 4.61 1.75 4.82 4.49 1.82 4.69 4.34 1.73<br />
18.0 25.0 6.06 5.15 1.44 5.82 5.00 1.45 5.50 4.83 1.71 5.35 4.69 1.78 5.14 4.57 1.85 5.02 4.42 1.73<br />
19.0 27.0 6.22 5.19 1.46 5.98 5.05 1.47 5.67 4.89 1.73 5.50 4.73 1.78 5.31 4.63 1.85 5.18 4.49 1.73<br />
22.0 30.0 6.72 5.30 1.46 6.48 5.17 1.50 6.16 5.02 1.77 6.00 4.88 1.87 5.80 4.77 1.88 5.67 4.64 1.75<br />
24.0 32.0 7.05 5.40 1.45 6.81 5.27 1.51 6.49 5.13 1.80 6.33 4.99 1.91 6.13 4.90 1.92 6.00 4.76 1.78<br />
Capacity tables<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Heating Capacity<br />
Model ATNH18GPLED[UT18 NPD]<br />
AFR 17<br />
Indoor Air<br />
Temperature<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
TC SHC PI<br />
4.24 4.10 1.49<br />
4.57 4.21 1.51<br />
4.90 4.30 1.47<br />
5.06 4.37 1.46<br />
5.55 4.52 1.46<br />
5.88 4.65 1.49<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 4.31 2.03 4.60 2.07 5.13 1.96 5.65 1.83 6.15 1.73 6.55 1.69 6.73 1.60<br />
18 4.26 2.06 4.59 2.12 5.14 2.02 5.64 1.89 6.11 1.77 6.47 1.72 6.70 1.62<br />
20 4.24 2.10 4.59 2.17 5.14 2.08 5.63 1.94 6.05 1.81 6.43 1.75 6.72 1.63<br />
21 4.22 2.12 4.59 2.20 5.14 2.11 5.61 1.96 6.01 1.83 6.43 1.76 6.67 1.63<br />
22 4.22 2.14 4.59 2.23 5.14 2.14 5.60 1.99 5.97 1.84 6.42 1.77 6.62 1.63<br />
24 4.18 2.18 4.54 2.27 5.08 2.17 5.57 2.01 5.96 1.85 6.31 1.77 6.58 1.64<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 203
Capacity tables 5CSL0-06B<br />
Models : AUUW216DH + ATNH21GNLED<br />
[UU21WH U4D] + [UT21 NND]<br />
• Cooling Capacity<br />
Model ATNH21GNLED[UT21 NND]<br />
AFR 19<br />
Indoor Air<br />
Temperature<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Heating Capacity<br />
Model ATNH21GNLED[UT21 NND]<br />
AFR 19<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 7.84 7.10 1.38 7.50 6.87 1.44 7.04 6.59 1.93 6.83 6.37 2.16 6.53 6.18 2.37 6.35 5.96 2.32<br />
16.0 22.0 8.33 7.19 1.87 7.98 6.98 1.89 7.52 6.72 2.28 7.31 6.50 2.45 7.01 6.32 2.55 6.83 6.11 2.43<br />
18.0 25.0 8.81 7.26 2.02 8.46 7.05 2.03 8.00 6.81 2.39 7.78 6.60 2.50 7.48 6.44 2.59 7.30 6.24 2.43<br />
19.0 27.0 9.05 7.32 2.04 8.70 7.12 2.06 8.24 6.89 2.42 8.00 6.67 2.50 7.72 6.52 2.60 7.54 6.32 2.42<br />
22.0 30.0 9.78 7.47 2.04 9.43 7.28 2.10 8.96 7.07 2.48 8.73 6.87 2.62 8.43 6.73 2.64 8.25 6.53 2.44<br />
24.0 32.0 10.26 7.60 2.03 9.91 7.43 2.12 9.44 7.23 2.52 9.21 7.03 2.67 8.91 6.90 2.69 8.73 6.71 2.50<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.40 2.89 6.84 2.94 7.64 2.79 8.40 2.61 9.15 2.46 9.75 2.40 10.01 2.28<br />
18 6.34 2.93 6.83 3.01 7.65 2.88 8.39 2.68 9.09 2.52 9.62 2.45 9.97 2.31<br />
20 6.30 2.98 6.83 3.09 7.65 2.96 8.37 2.75 9.00 2.57 9.56 2.48 9.99 2.32<br />
21 6.28 3.01 6.83 3.13 7.65 3.00 8.35 2.79 8.94 2.60 9.56 2.50 9.93 2.32<br />
22 6.27 3.05 6.83 3.18 7.65 3.04 8.33 2.82 8.88 2.62 9.55 2.51 9.85 2.32<br />
24 6.21 3.10 6.76 3.22 7.56 3.08 8.28 2.85 8.87 2.64 9.39 2.52 9.79 2.33<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
TC SHC PI<br />
6.17 5.77 2.08<br />
6.65 5.94 2.11<br />
7.12 6.06 2.06<br />
7.36 6.15 2.04<br />
8.07 6.37 2.04<br />
8.55 6.55 2.09<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
204 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW246DH + ATNH24GNLED<br />
[UU24WH U4D] + [UT24 NND]<br />
• Cooling Capacity<br />
Model ATNH24GPLED[UT24 NND]<br />
AFR 21<br />
Capacity tables<br />
• Symbol<br />
AFR : Air flow rate [m3 Indoor Air<br />
Outdoor Air Temperature : °CDB<br />
Temperature 20 25 32 35 40 43 46<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.24 7.78 1.43 7.88 7.53 1.50 7.40 7.23 2.01 7.17 6.98 2.24 6.86 6.77 2.46 6.67 6.53 2.41 6.48 6.33 2.16<br />
16.0 22.0 8.74 7.89 1.94 8.38 7.65 1.96 7.90 7.37 2.37 7.67 7.13 2.54 7.36 6.93 2.65 7.17 6.70 2.52 6.98 6.51 2.19<br />
18.0 25.0 9.25 7.95 2.10 8.89 7.73 2.11 8.40 7.47 2.49 8.17 7.24 2.59 7.86 7.06 2.69 7.67 6.84 2.52 7.48 6.65 2.14<br />
19.0 27.0 9.50 8.02 2.12 9.14 7.81 2.14 8.65 7.55 2.51 8.40 7.31 2.59 8.11 7.15 2.70 7.92 6.93 2.51 7.73 6.75 2.12<br />
22.0 30.0 10.26 8.18 2.12 9.90 7.98 2.18 9.41 7.75 2.57 9.17 7.53 2.72 8.86 7.38 2.74 8.67 7.16 2.54 8.48 6.99 2.12<br />
24.0 32.0 10.77 8.34 2.11 10.40 8.14 2.20 9.91 7.93 2.62 9.67 7.71 2.77 9.36 7.56 2.80 9.17 7.35 2.60 8.98 7.18 2.17<br />
• Notes<br />
/min] 1. All capacites are net, evaporator fan motor heat is<br />
DB : Dry bulb temperature [°C]<br />
deducted.<br />
WB : Wet bulb temperature [°C] 2. Indicates rated capacity.<br />
TC : Total capacity [kW] 3. Direct interpolation is permissible. Do not extrapolate<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
• Heating Capacity<br />
Model ATNH24GPLED[UT24 NND]<br />
AFR 21<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CWB<br />
-15 -10 -5 0 6 10 15<br />
˚CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 6.69 3.10 7.14 3.16 7.98 3.00 8.77 2.80 9.56 2.64 10.18 2.57 10.45 2.44<br />
18 6.63 3.15 7.13 3.23 7.99 3.09 8.77 2.88 9.49 2.71 10.05 2.63 10.42 2.47<br />
20 6.58 3.20 7.13 3.31 7.99 3.17 8.74 2.95 9.40 2.76 9.98 2.66 10.43 2.48<br />
21 6.56 3.23 7.13 3.36 7.99 3.22 8.72 2.99 9.34 2.79 9.98 2.68 10.37 2.49<br />
22 6.55 3.27 7.13 3.41 7.99 3.26 8.70 3.03 9.27 2.81 9.97 2.70 10.28 2.49<br />
24 6.49 3.32 7.06 3.46 7.89 3.30 8.65 3.06 9.26 2.83 9.81 2.70 10.22 2.50<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 205
Capacity coefficient factor 5CSL0-06B<br />
2.1.8 Capacity coefficient factor<br />
DC Inverter SINGLE A.(1Ø)<br />
1) Rate <strong>of</strong> change in capacity due to the main piping length<br />
Rate <strong>of</strong> change in cooling capacity<br />
Main piping length(m)<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
Rate <strong>of</strong> change in heating capacity<br />
Main piping length(m)<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
DC Inverter SINGLE A.(3Ø)<br />
5 10 15 20 30 40 50 60 70 75<br />
3.5 kW 100 99.8 99.3 - - - - - - -<br />
5.0 kW 100 99.8 99.3 98.8 97.8 96.9 97.7 - - -<br />
7.1/8.0/10.0 kW 100 99.3 97.9 96.6 93.8 91.1 88.4 - - -<br />
12.5/14.0/15.0 kW 100 99.3 97.9 96.6 93.8 91.1 88.4 85.6 82.9 81.5<br />
5 10 15 20 30 40 50 60 70 75<br />
3.5 kW 100 99.8 99.4 - - - - - - -<br />
5.0 kW 100 99.8 99.4 99.0 98.3 97.5 98.3 - - -<br />
7.1/8.0/10.0 kW 100 99.7 99.2 98.7 97.7 96.6 95.6 - - -<br />
12.5/14.0/15.0 kW 100 99.7 99.2 98.7 97.7 96.6 95.6 94.6 93.5 93<br />
1) Rate <strong>of</strong> change in capacity due to the main piping length<br />
Rate <strong>of</strong> change in cooling capacity<br />
Main piping length(m)<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
Rate <strong>of</strong> change in heating capacity<br />
Main piping length(m)<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
5 10 15 20 30 40 50 60 70 75<br />
10.0 kW 100 99.3 97.9 96.6 93.8 91.1 88.4 - - -<br />
12.5/14.0/15.0 kW 100 99.3 97.9 96.6 93.8 91.1 88.4 85.6 82.9 81.5<br />
5 10 15 20 30 40 50 60 70 75<br />
10.0 kW 100 99.7 99.2 98.7 97.7 96.6 95.6 - - -<br />
12.5/14.0/15.0 kW 100 99.7 99.2 98.7 97.7 96.6 95.6 94.6 93.5 93<br />
206 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
3) Calculation <strong>of</strong> actual system capacity<br />
① Outdoor unit rated capacity<br />
Qodu(rated) [from specification table]<br />
② Outdoor unit capacity at Ti, To temperature.<br />
Qodu(Ti, To) [from capacity table]<br />
③ Outdoor unit capacity coefficient factor<br />
F(Ti, To) = Qodu(Ti, To) / Qodu(rated)<br />
④ Piping correction factor [from capacity coefficient factor table]<br />
Fmain (length, elevation) for main piping length or elevation<br />
Fbranch (length, elevation) for branch piping length or elevation<br />
⑤ Individual indoor unit combinational capacity<br />
Qidu (combi) = Qodu(rated) x Qidu(rated) / Qidu(rated-total)<br />
⑥ Individual indoor unit actual capacity<br />
Qidu (actual) = Qodu(combi) x F(Ti, To) x Fmain (length, elevation) x Fbranch (length, elevation)<br />
Exam<strong>pl</strong>e) • Outdoor unit model : AUUW126D[UU12W ULD]<br />
• Indoor units (ATNH12GRLED[UT12 NRD]) : 3.5 kW<br />
• Outdoor temperature : 40.0°CDB<br />
• Indoor temperature: 19.0°CWB<br />
• Main piping length(O/D to BD):15m<br />
• Indoor unit actual cooling capacity in A room?<br />
- Qodu(rated) : 3.40kW<br />
- Qodu(Ti, To) : 3.28 kW<br />
- F(Ti, To) : 3.28 / 3.40 = 96.47%<br />
- Fmain (length, elevation) = 99.3%<br />
- Qind(actual) =3.4kW x 0.9647 x 0.993 = 3.257kW<br />
Capacity coefficient factor<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 207
Operation range 5CSL0-06B<br />
2.1.9 Operation range<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
46<br />
43<br />
21<br />
-5<br />
-10<br />
Cooling<br />
Operative<br />
Continuous<br />
operation<br />
18 32<br />
Indoor Unit [°C DB]<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
208 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
24<br />
-10<br />
-15<br />
Warming up<br />
Operation<br />
Heating<br />
Continuous<br />
operation<br />
Operative<br />
16 30<br />
Indoor Unit [°C DB]<br />
Operative: Intermittent operation due to the operational<br />
conditions (indoor/outdoor temperature,<br />
humidity, load etc.) can cause the heating<br />
capacity to decrease
5CSL0-06B<br />
2.1.10 Electric characteristics<br />
Unit<br />
Electric characteristics<br />
Power Compressor OFM<br />
Model Type Hz Voltage Voltage range MCA MOP MSC RLA kW FLA<br />
AUUW096D[UU09W ULD]<br />
AUUW126D[UU12W ULD]<br />
AUUW186D[UU18W UED]<br />
AUUW186D1[UU18W UED1]<br />
AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED]<br />
AUUW366D[UU36W UED]<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW368D[UU37WUED]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
AUUW186DH[UU18WH UED]<br />
AUUW216DH[UU21WH U4D]<br />
AUUW246DH[UU24WH U4D]<br />
1 Phase<br />
inverter<br />
3 phase<br />
inverter<br />
DC Inverter<br />
High<br />
Efficiency<br />
50<br />
50<br />
50<br />
220-240<br />
380-415<br />
220-240<br />
Notes :<br />
1. Voltage range<br />
Voltage sup<strong>pl</strong>ied to the unit terminals should be within the<br />
minimum and maximum range<br />
2. Maximum allowable voltage unbalance between phase is 2 %<br />
3. MCA / MOP<br />
MCA = (1.25 x Load1) + Load2 + Load3<br />
MOP = (2.25 x Load1) + Load2 + Load3<br />
- Load1 : Rated running current <strong>of</strong> largest motor<br />
(compressor or other motor)<br />
- Load2 : sum <strong>of</strong> current for all other motors<br />
- Load3 : any other load rated 1.0A or more<br />
4. Select wire spec. based on the MCA<br />
5. Recommended circuit breaker is ELCB (Earth Leakage circuit<br />
breaker)<br />
6. MSC & RLA are measured as the compressor only test<br />
condition.<br />
7. MSC values<br />
Min. : 198<br />
Max. :264<br />
Min. : 352<br />
Max. : 457<br />
Min. : 198<br />
Max. :264<br />
4.25 7.65 3.40 3.40 0.043 0.25<br />
6.25 11.25 5.00 5.00 0.043 0.25<br />
8.75 15.75 7.00 7.00 0.084 0.05<br />
13.00 23.40 - 8.1 0.12 0.60<br />
13.38 24.08 10.70 10.70 0.12 0.60<br />
16.25 29.25 13.00 13.00 0.12 0.60<br />
17.75 31.95 14.20 14.20 0.16 0.70<br />
23.33 41.03 17.70 17.70 0.24 1.20<br />
26.83 47.33 20.50 20.50 0.24 1.20<br />
32.08 56.78 24.70 24.70 0.24 1.20<br />
8.75 15.75 10.00 7.00 0.16 0.70<br />
6.55 10.83 4.28 4.28 0.24 1.20<br />
7.74 12.97 5.23 5.23 0.24 1.20<br />
8.59 14.50 5.91 5.91 0.24 1.20<br />
6.25 11.25 5.0 5.0 0.12 0.6<br />
8.62 15.5 6.9 6.9 0.12 0.6<br />
10.6 19.1 8.5 8.5 0.12 0.6<br />
8. RLA is measured during each individual compressor test<br />
condition.<br />
9. OFM is measured as the outdoor unit test condition<br />
(Exam<strong>pl</strong>e) Selection <strong>of</strong> proper circuit breaker<br />
Model : AUUW186D [UU18W UED]<br />
Rated running current : 7.0A (refer to spec. sheet)<br />
MCA = (1.25 x Load1) + Load2 + Load3<br />
= (1.25 x 7.0) + 0 + 0 = 8.75A<br />
MOP = (2.25 x Load1) + Load2 + Load3<br />
= (2.25 x 7.0) + 0 + 0 = 15.75A<br />
→ Finally select circuit breaker 15A(Min. circuit breaker is 15A)<br />
MCA : Minimum Circuit Amperes (A)<br />
MOP : Maximum rating over current protective device<br />
MSC : Maximum Starting Current<br />
RLA : Rated Load Amperes (A)<br />
OFM : Outdoor Fan Motor<br />
kW : Fan Motor rated output (kW)<br />
FLA : Full Load Amperes (A)<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 209
Field wiring diagrams 5CSL0-06B<br />
2.1.11 Field wiring diagrams<br />
DC Inverter SINGLE A(1Ø)<br />
1. All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
2. Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the current as required by the air conditioner.<br />
3. Feed the power source to the unit via a distribution switch board designed for this purpose.<br />
4. The terminal screws inside the control box may be loose due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can overload and damage electrical components.)<br />
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.<br />
L<br />
N<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
Circuit breaker<br />
Fuse<br />
Power cable 3 core x 2.5/5.0mm 2<br />
(Including earth)<br />
L<br />
N<br />
G<br />
Outdoor unit<br />
Terminal Block outdoor<br />
1(L) 2(N) 4(L) 5(N) 3<br />
1(L) 2(N) 3<br />
Terminal block indoor<br />
Notes:<br />
1. All wirings, components and materials to be procured on the site should be according to the standard<br />
2. Use copper conductor only<br />
3. Install circuit breaker for safety<br />
4. Unit should be grounded in com<strong>pl</strong>iance with the ap<strong>pl</strong>icable local and national codes<br />
5. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Transmission<br />
line<br />
210 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)
5CSL0-06B<br />
DC Inverter SINGLE A(3Ø)<br />
R<br />
S<br />
T N<br />
Circuit breaker<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
Fuse<br />
Power cable 5 core x 2.5mm 2<br />
(Including earth)<br />
R<br />
S<br />
T N<br />
Outdoor unit<br />
Terminal Block outdoor<br />
R S T N 1(L) 2(N) 3 4 5<br />
1(L) 2(N) 3<br />
Terminal block indoor<br />
Notes:<br />
1. All wirings, components and materials to be procured on the site should be according to the standard<br />
2. Use copper conductor only<br />
3. Install circuit breaker for safety<br />
4. Unit should be grounded in com<strong>pl</strong>iance with the ap<strong>pl</strong>icable local and national codes<br />
5. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Field wiring diagrams<br />
Transmission<br />
cable<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 211
Sound levels 5CSL0-06B<br />
2.1.12 Sound levels<br />
Sound Pressure Level (dB re 20 Pa)<br />
DC Inverter SINGLE A(1Ø, 3Ø)<br />
Overall<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
D<br />
1m<br />
1m<br />
1m<br />
1m<br />
15m<br />
Sound pressure level<br />
AUUW096D[UU09W ULD]<br />
AUUW126D[UU12W ULD]<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound Pressure Level (dB re 20 Pa )<br />
Center <strong>of</strong><br />
Outdoor Unit<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Notes:<br />
- Sound measured at 1m away from the center <strong>of</strong> the unit.<br />
- Data is valid at free field condition<br />
- Data is valid at nominal operation condition<br />
- Reference accoustic pressure OdB = 20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as the<br />
construction(acoustic absorption coefficient) <strong>of</strong> particular room in<br />
which the equipment is installed.<br />
- The operating conditions are assumed to be standard<br />
AUUW186D[UU18W UED]<br />
AUUW186D1[UU18W UED1]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Octave Band Center Frequency (Hz)<br />
212 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20μPa )<br />
AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED]
5CSL0-06B<br />
AUUW366D[UU36W UED] AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
Sound Pressure Level (dB re 20μPa )<br />
Octave Band Center Frequency (Hz)<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
Sound levels<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 213<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound Pressure Level (dB re 20 Pa )<br />
AUUW368D[UU37W UED]<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
Sound levels 5CSL0-06B<br />
High Efficiency models(1Ø)<br />
Overall<br />
1m<br />
Sound pressure level<br />
Sound Pressure Level (dB re 20μPa )<br />
Octave Band Center Frequency (Hz)<br />
Microphone<br />
1m<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Notes:<br />
- Sound measured at 1m away from the center <strong>of</strong> the unit.<br />
- Data is valid at free field condition.<br />
- Data is valid at nominal operation condition.<br />
- Reference accoustic pressure 0dB=20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
AUUW186DH[UU18WH UED] AUUW216DH [UU21WH U4D]<br />
AUUW246DH [UU24WH U4D]<br />
Sound Pressure Level (dB re 20μPa )<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
214 Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15
5CSL0-06B<br />
2.1.13 Accessories<br />
Standard accessories<br />
• See the "Installation manual"<br />
Optional accessories (For 3Ø models only)<br />
NOTE<br />
No. Accessory Name Model Name Remarks<br />
1 Air Guide<br />
2<br />
3<br />
Central control<br />
Gateway<br />
PQAGA<br />
PQCSA101S0<br />
PQCSA101S0<br />
PQCSW502A0<br />
PQCSS101S0<br />
PQCSS502A0<br />
PHNFP14A0<br />
PQNFG00A0<br />
* For the detail information, see the "CAC ACCESSORIES Product Data book"<br />
For Air discharge change<br />
Sim<strong>pl</strong>e Type<br />
Deluxe Type<br />
PC Based Type<br />
PI485<br />
CNU<br />
Accessories<br />
Outdoor unit - DC Inverter SINGLE A (1Ø, 3Ø) 215
Power sup<strong>pl</strong>y 5CSL0-06B<br />
2.2 DC Inverter SINGLE A - Synchro (1Ø, 3Ø)<br />
2.2.1 Power sup<strong>pl</strong>y<br />
Type Outdoor unit Capacity (kW) Circuit breaker capacity Power sup<strong>pl</strong>y<br />
1 Phase<br />
Inveter<br />
3 Phase<br />
Inverter<br />
AUUW426D[UU42W U3D] 12.5<br />
AUUW486D[UU48W U3D] 14.0 50A 1Ø, 220-240 V, 50Hz<br />
AUUW606D[UU60W U3D] 15.0<br />
AUUW428D(UU43W U3D) 12.5<br />
AUUW488D[UU49W U3D] 14.0 25A 3Ø, 380-415 V, 50Hz<br />
AUUW608D[UU61W U3D] 15.0<br />
External wiring procedure<br />
- The power sup<strong>pl</strong>y work is needed only to the outdoor unit. The power sup<strong>pl</strong>y to the indoor unit is conducted through the<br />
transmission wiring. Therefore, the power sup<strong>pl</strong>y work can be carried out at just one <strong>pl</strong>ace <strong>of</strong> the outdoor unit. It will<br />
contribute to sim<strong>pl</strong>ify the work procedure and to save cost.<br />
- Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
(Ex. Duo simultaneous operation)<br />
Circuit<br />
breaker<br />
(Ex. Trio simultaneous operation)<br />
Circuit<br />
breaker<br />
AUUW606D<br />
[UU60W U3D]<br />
AUUW606D<br />
[UU60W U3D]<br />
(Ex. Quartet simultaneous operation)<br />
Circuit<br />
breaker<br />
AUUW606D<br />
[UU60W U3D]<br />
Branch kit(PMUB11A)<br />
ATNH30GPLED<br />
[UT30NPD]<br />
Branch kit(PMUB111A)<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
Branch kit(PMUB1111A)<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
ATNH30GPLED<br />
[UT30NPD]<br />
Only one remote controller.<br />
Only one circuit breaker.<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
ATNH18GQLED<br />
[UT18 NQD]<br />
Only one remote controller.<br />
Only one circuit breaker.<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
Only one remote controller.<br />
Only one circuit breaker.<br />
ATNH12GRLED<br />
[UT12 NRD]<br />
216 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.2.2 List <strong>of</strong> functions<br />
DC Inverter Synchro(1Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Auto operation(Artificial intelligence)<br />
Convenience<br />
Auto Restart Operation<br />
Central control(LGAP)<br />
CAC Network<br />
PDI(Power Distribution Indicator)<br />
Function<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
DC Inverter Synchro(3Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Auto operation(Artificial intelligence)<br />
Convenience<br />
Auto Restart Operation<br />
Central control(LGAP)<br />
CAC Network<br />
PDI(Power Distribution Indicator)<br />
Function<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
AUUW426D<br />
[UU42W U3D]<br />
AUUW486D<br />
[UU48W U3D]<br />
List <strong>of</strong> functions<br />
AUUW606D<br />
[UU60W U3D]<br />
O O O<br />
O O O<br />
- - -<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O<br />
(program logic) (program logic) (program logic)<br />
- - -<br />
AUUW428D<br />
[UU43W U3D]<br />
AUUW488D<br />
[UU49W U3D]<br />
AUUW608D<br />
[UU61W U3D]<br />
O O O<br />
O O O<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O O O<br />
(program logic) (program logic) (program logic)<br />
- - -<br />
• Group control is not available which is connected with UU48W & UU60W<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 217
Specifications 5CSL0-06B<br />
2.2.3 Specifications<br />
■ Capacity for sigle combination<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
ATNH42GMLED<br />
[UT42 NMD]<br />
AUUW426D<br />
[UU42W U3D]<br />
ATNH48GMLED<br />
[UT48 NMD]<br />
Notes:<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m(25ft)<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Due to our policy <strong>of</strong> innovation some specifications may be changed without notification.<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
AUUW486D<br />
AUUW606D<br />
[UU48W U3D]<br />
[UU60W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.48 ~ 13.9 ~ 15.7 5.92 ~ 14.6 ~ 16.3<br />
5.6 ~ 14.0 ~ 15.4 6.4 ~ 15.5 ~ 17.6 6.8 ~ 16.9 ~ 18.7<br />
3.89 4.61 5.40<br />
3.87 4.54 5.50<br />
UVNH426LLAD<br />
[UV42 NLD]<br />
AUUW426D<br />
[UU42W U3D]<br />
UVNH486LLAD<br />
[UV48 NLD]<br />
UVNH606LLAD<br />
[UV60 NLD]<br />
AUUW486D<br />
AUUW606D<br />
[UU48W U3D]<br />
[UU60W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.32 ~ 13.3 ~ 14.6 5.72 ~ 14.4 ~ 15.7<br />
5.6 ~ 13.6 ~ 15.4 6.4 ~ 15.3 ~ 17.6 6.8 ~ 16.8 ~ 18.7<br />
4.00 4.41 5.30<br />
3.98 4.76 5.50<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
AUUW426D<br />
[UU42W U3D]<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
AUUW486D<br />
AUUW606D<br />
[UU48W U3D]<br />
[UU60W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.6 ~ 14.0 ~ 15.4 5.92 ~ 14.8 ~ 16.3<br />
5.6 ~ 14.0 ~ 15.4 6.6 ~ 16.4 ~ 18.2 6.8 ~ 16.8 ~ 18.7<br />
4.15 4.65 5.26<br />
3.73 4.54 4.57<br />
218 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
■ Capacity for sigle combination<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
ATNH42GMLED<br />
[UT42 NMD]<br />
AUUW428D<br />
[UU43W U3D]<br />
ATNH48GMLED<br />
[UT48 NMD]<br />
Notes:<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m(25ft)<br />
- Level Difference <strong>of</strong> Zero.<br />
2. Due to our policy <strong>of</strong> innovation some specifications may be changed without notification.<br />
Specifications<br />
ATNH60GMLED<br />
[UT60 NMD]<br />
AUUW488D<br />
AUUW608D<br />
[UU49W U3D]<br />
[UU61W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.48 ~ 13.8 ~ 15.7 5.92 ~ 14.7 ~ 16.3<br />
5.6 ~ 14.0 ~ 15.4 6.4 ~ 15.9 ~ 17.6 6.8 ~ 17.0 ~ 18.7<br />
3.89 4.58 5.63<br />
3.87 4.66 5.64<br />
UVNH426LLAD<br />
[UV42 NLD]<br />
AUUW428D<br />
[UU43W U3D]<br />
UVNH486LLAD<br />
[UV48 NLD]<br />
UVNH606LLAD<br />
[UV60 NLD]<br />
AUUW488D<br />
AUUW608D<br />
[UU49W U3D]<br />
[UU61W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.32 ~ 13.3 ~ 14.6 5.72 ~ 14.4 ~ 15.7<br />
5.6 ~ 13.6 ~ 15.4 6.4 ~ 15.3 ~ 17.6 6.8 ~ 16.8 ~ 18.7<br />
4.00 4.41 5.30<br />
3.98 4.76 5.50<br />
ABNH426RLAD<br />
[UB42 NRD]<br />
AUUW428D<br />
[UU43W U3D]<br />
ABNH486RLAD<br />
[UB48 NRD]<br />
ABNH606RLAD<br />
[UB60 NRD]<br />
AUUW488D<br />
AUUW608D<br />
[UU49W U3D]<br />
[UU61W U3D]<br />
5.0 ~ 12.5 ~ 13.8 5.6 ~ 14.0 ~ 15.4 5.92 ~ 14.8 ~ 16.3<br />
5.6 ~ 14.0 ~ 15.4 6.6 ~ 16.7 ~ 18.2 6.8 ~ 17.0 ~ 18.7<br />
4.15 4.65 5.26<br />
3.82 4.57 4.70<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 219
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, V, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Model<br />
Quantity<br />
Motor Input kW<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge* g<br />
Type<br />
Control<br />
Heat exchnager Tube Size (OD) mm<br />
Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Fan Type<br />
No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level(H/L) Sound Press,1m dB(A)+3<br />
Defrosting<br />
SVC Valve Liquid mm<br />
Gas mm<br />
Max. Interunit Total Piping(Main+Total Branch) m<br />
Piping Length Main Piping m<br />
Total Branch Piping m<br />
Each Branch Piping m<br />
Max. Installation Indoor Unit~Outdoor Unit m<br />
Height Difference Indoor Unit~Indoor Unit m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
AUUW426D<br />
[UU42W U3D]<br />
AUUW486D<br />
[UU48W U3D]<br />
Synchro ap<strong>pl</strong>ication<br />
(simultaneous operation).<br />
Refer to combination table.<br />
AUUW606D<br />
[UU60W U3D]<br />
17.7/16.7 20.5/20.5 24.7/23.5<br />
- - -<br />
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50<br />
3*5.0 3*5.0 3*5.0<br />
4*0.75 4*0.75 4*0.75<br />
950*1,380*330 950*1,380*330 950*1,380*330<br />
103 103 103<br />
Rotary Rotary Rotary<br />
5JD420XAD22 5JD420XAD22 5JD420XAD22<br />
1 1 1<br />
4.18 4.18 4.18<br />
1,300 1,300 1,300<br />
FV50S(PVE) FV50S(PVE) FV50S(PVE)<br />
3,600 3,600 3,600<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
0.276(7.0) 0.276(7.0) 0.276(7.0)<br />
17 17 17<br />
2R,24C X 2 2R,32C x 2 2R,32C x 2<br />
SIC-72FW-F1124-3 SIC-72FW-F1124-3 SIC-72FW-F1124-3<br />
0.124 X 2 0.124 X 2 0.124 X 2<br />
- - -<br />
Propeller Propeller Propeller<br />
526/1 526/1 526/1<br />
Side Discharge Side Discharge Side Discharge<br />
55(1,942) x 2 55(1,942) x 2 55(1,942) x 2<br />
55/51 55/51 55/51<br />
Reversing cycle Reversing cycle Reversing cycle<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
80 80 80<br />
50 50 50<br />
40 40 40<br />
15 15 15<br />
30 30 30<br />
1 1 1<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
220 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power sup<strong>pl</strong>y Ø, V, Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable(Includes earth) No.* mm 2<br />
Dimensions W*H*D mm<br />
Net Weight Outdoor kg<br />
Compressor Type<br />
(Inverter) Model<br />
Quantity<br />
Motor Input kW<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge* g<br />
Type<br />
Control<br />
Heat exchnager Tube Size (OD) mm<br />
Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Fan Type<br />
No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level(H/L) Sound Press,1m dB(A)+3<br />
Defrosting<br />
SVC Valve Liquid mm<br />
Gas mm<br />
Max. Interunit Total Piping(Main+Total Branch) m<br />
Piping Length Main Piping m<br />
Total Branch Piping m<br />
Each Branch Piping m<br />
Max. Installation Indoor Unit~Outdoor Unit m<br />
Height Difference Indoor Unit~Indoor Unit m<br />
Note :<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
AUUW428D<br />
[UU43W U3D]<br />
AUUW488D<br />
[UU49W U3D]<br />
Synchro ap<strong>pl</strong>ication<br />
(simultaneous operation).<br />
Refer to combination table.<br />
2. Due to our policy <strong>of</strong> innovation some specifications<br />
may be changed without notification.<br />
3. At least two indoor units should be connected.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national<br />
code.<br />
Specifications<br />
AUUW608D<br />
[UU61W U3D]<br />
4.09/4.28 4.98/5.23 5.91/5.79<br />
- - -<br />
3, 380-415, 50 3, 380-415, 50 3, 380-415, 50<br />
5 x 2.5 5 x 2.5 5 x 2.5<br />
4 x 0.75 (Including Earth) 4 x 0.75 (Including Earth) 4 x 0.75 (Including Earth)<br />
950*1,380*330 950*1,380*330 950*1,380*330<br />
103 103 103<br />
Rotary Rotary Rotary<br />
5JD420XBB22 5JD420XBB22 5JD420XBB22<br />
1 1 1<br />
4.18 4.18 4.18<br />
1,300 1,300 1,300<br />
FV50S (PVE) FV50S (PVE) FV50S (PVE)<br />
3,600 3,600 3,600<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
0.276 0.276 0.276<br />
17 17 17<br />
2R, 32C x 2 2R, 32C x 2 2R, 32C x 2<br />
SIC-72FW-F1124-3 SIC-72FW-F1124-3 SIC-72FW-F1124-3<br />
0.124*2 0.124*2 0.124*2<br />
- - -<br />
Propeller Propeller Propeller<br />
2/526 2/526 2/526<br />
Side Discharge Side Discharge Side Discharge<br />
55 x 2 55 x 2 55 x 2<br />
55/51 55/51 55/51<br />
Reversing cycle Reversing cycle Reversing cycle<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
80 80 80<br />
50 50 50<br />
40 40 40<br />
15 15 15<br />
30 30 30<br />
1 1 1<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 221
Combination table 5CSL0-06B<br />
2.2.4 Combination table<br />
Possible combinations<br />
IDU : INDOOR UNIT<br />
ODU : OUT DOOR INUT<br />
BD : BRANCH DISTRIBUTOR UNIT<br />
REMO : WIRED REMOTE CONTROLLER<br />
OUTDOOR Capacity (kW)<br />
UNITS<br />
AUUW426D<br />
Cooling Heating<br />
[UU42W U3D]<br />
AUUW428D<br />
[UU43W U3D]<br />
AUUW486D<br />
12.5 14.0<br />
[UU48W U3D]<br />
AUUW488D<br />
[UU49W U3D]<br />
AUUW606D<br />
14.0 16.0<br />
[UU60W U3D]<br />
AUUW608D<br />
[UU61W U3D]<br />
15.0 17.0<br />
Wired remote<br />
controller*<br />
Ap<strong>pl</strong>ied<br />
Accessiries<br />
BD unit<br />
Sim<strong>pl</strong>e central<br />
controller**<br />
Function<br />
controller**<br />
Duo<br />
ODU<br />
Cassette Duct Ceiling & Floor<br />
UT24 NPD *2<br />
UT24 NPD *2<br />
UT30 NPD *2<br />
PMUB11A<br />
Possible combination <strong>of</strong> indoor units<br />
Synchro<br />
Quartet<br />
222 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)<br />
Trio<br />
ODU<br />
BD<br />
BD BD<br />
IDU IDU IDU IDU IDU IDU IDU IDU IDU<br />
REMO REMO REMO<br />
UB24 NHD *2<br />
UB24 NHD *2<br />
UB30 NGD *2<br />
UV24 NBD *2<br />
UV24 NHD *2<br />
UV30 NGD *2<br />
Cassette Duct Ceiling & Floor Cassette Duct Ceiling & Floor<br />
UT18 NQD*3<br />
UT18 NQD*3<br />
UT18 NQD*3<br />
UB18 NHD*3<br />
UB18 NHD*3<br />
UB18 NHD*3<br />
PVRCUSZO PVRCUSZO<br />
PMUB111A PMUB1111A<br />
PQCSB101S0<br />
PQCSC101S0<br />
UV18 NBD*3<br />
UV18 NBD*3<br />
UV18 NBD*3<br />
UT12 NRD*4<br />
UT12 NRD*4<br />
UT12 NRD*4<br />
Notes :<br />
1. Possible indoor units: indoor unit series<br />
• Dry contact & Zone control & Auto changeover is not available which is connected with synchro.<br />
• When using synchro operation<br />
- Do not use wireless remote controller<br />
- Use only one wired remote controller in the indoor units.<br />
- Use central and function controller "PQCSB101S0" & "PQCSC101S0" only<br />
2. Between units are the required Branch kits mentioned, that are necessary to install the combination.<br />
(Gas pipe)<br />
(Liquid pipe)<br />
Indoor Classification<br />
2 Units<br />
3 Units<br />
4 Units<br />
C<br />
A<br />
Model Name<br />
PMUB11A<br />
PMUB111A<br />
PMUB1111A<br />
a b c<br />
a b<br />
Type 1 Type 2<br />
B<br />
D<br />
Capacity Ratio(%)<br />
50:50 (1:1)<br />
33:33:33 (1:1:1)<br />
25:25:25:25(1:1:1:1)<br />
(I.D)<br />
ODU<br />
-<br />
-<br />
-<br />
Unit : mm (inch)<br />
ⓐ ⓑ ⓒ Type<br />
Ⓐ Ø15.88(5/8) Ø19.05(3/4) Ø25.4(1) 1<br />
Ⓑ<br />
Ø9.52(3/8)<br />
Ø12.7(1/2)<br />
Ø12.7(1/2)<br />
Ø15.88(5/8)<br />
- 2<br />
Ⓒ Ø6.35(1/4) Ø9.52(3/8) - 2<br />
Ⓓ Ø9.52(3/8) Ø12.7(1/2) - 2<br />
-<br />
-<br />
-
5CSL0-06B<br />
■ 1Ø Synchro Equivalent capacity table<br />
AUUW426D[UU42W U3D] (Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Combination table<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 5.60 14.0 14.0 8.20 20.5 20.5 1.84 4.60 4.60<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 15.0 9.00 22.6 22.6 2.08 5.20 5.20<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 14.0 8.25 21.5 22.0 1.91 4.69 4.82<br />
• Heating<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 6.40 16.0 16.0 8.20 20.5 20.5 1.84 4.60 4.60<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 17.0 8.70 21.7 21.7 2.08 5.00 5.00<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 16.0 8.50 22.5 22.0 2.10 4.70 4.82<br />
AUUW486D[UU48W U3D] (Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 5.60 14.0 14.7 8.20 20.5 22.6 1.84 4.60 5.06<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 15.7 9.00 22.6 24.9 2.08 5.20 5.72<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 14.7 8.25 21.5 22.0 1.91 4.69 4.82<br />
• Heating<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 6.40 16.0 16.8 8.20 20.5 22.6 1.84 4.60 5.06<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 17.5 8.70 21.7 23.9 2.08 5.00 5.50<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 16.8 8.50 22.5 22.0 2.20 4.78 4.89<br />
• Notes<br />
1. Individual indoor capacities are not given because the combinations are for simultaneous operation.<br />
2. Rated cooling capacities are based on the following conditions:<br />
Indoor air temperature: 27°CDB, 19.0°CWB, outdoor temperature 35°CDB.<br />
Rated heating capacities are based on the following conditions:<br />
Indoor air temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB.<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 223
Combination table 5CSL0-06B<br />
AUUW606D[UU60W U3D] (Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Duo 8.0+8.0 16.0 6.00 15.0 16.5 9.32 23.3 24.0 2.24 5.60 5.80<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 16.5 9.00 22.6 22.6 2.08 5.20 5.20<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 15.4 8.25 21.5 22.0 1.91 4.69 4.82<br />
• Heating<br />
Simultaneous<br />
Operation<br />
• Notes<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 8.0+8.0 16.0 6.80 17.0 18.2 9.20 22.0 23.0 2.12 5.30 5.70<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 18.2 8.70 21.7 23.0 2.08 5.00 5.00<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 17.6 8.50 22.5 22.0 2.20 4.78 4.89<br />
1. Individual indoor capacities are not given because the combinations are for simultaneous operation.<br />
2. Rated cooling capacities are based on the following conditions:<br />
Indoor air temperature: 27°CDB, 19.0°CWB, outdoor temperature 35°CDB.<br />
Rated heating capacities are based on the following conditions:<br />
Indoor air temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB.<br />
224 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
■ 3Ø Synchro Equivalent capacity table<br />
AUUW428D[UU43W U3D](Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Combination table<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 5.60 14.0 14.0 1.99 4.98 5.47 1.84 4.60 4.60<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 15.0 2.36 5.91 6.50 2.08 5.20 5.20<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 14.0 2.02 5.10 5.50 1.91 4.69 4.82<br />
• Heating<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 6.40 16.0 16.0 2.10 5.23 5.75 1.84 4.60 4.60<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 17.0 2.31 5.79 6.36 2.08 5.00 5.00<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 16.0 2.30 5.40 5.90 1.91 4.69 4.82<br />
AUUW488D[UU49W U3D] (Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 5.60 14.0 14.7 1.99 4.98 5.47 1.84 4.60 5.06<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 15.7 2.36 5.91 6.50 2.08 5.20 5.72<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 14.7 2.02 5.10 5.50 1.91 4.69 5.12<br />
• Heating<br />
Simultaneous<br />
Operation<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 7.1+7.1 14.2 6.40 16.0 16.8 2.10 5.23 5.75 1.84 4.60 5.06<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 17.5 2.31 5.79 6.36 2.08 5.00 5.50<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 16.8 2.30 5.40 5.90 1.91 4.69 5.22<br />
• Notes<br />
1. Individual indoor capacities are not given because the combinations are for simultaneous operation.<br />
2. Rated cooling capacities are based on the following conditions:<br />
Indoor air temperature: 27°CDB, 19.0°CWB, outdoor temperature 35°CDB.<br />
Rated heating capacities are based on the following conditions:<br />
Indoor air temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB.<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 225
Combination table 5CSL0-06B<br />
AUUW608D[UU61W U3D] (Synchro-Duo, Trio, Quartet)<br />
• Cooling<br />
Simultaneous<br />
Operation<br />
Duo 8.0+8.0 16.0 6.00 15.0 16.5 1.99 4.98 5.47 2.24 5.60 5.80<br />
Trio 5.0+5.0+5.0 15.0 6.00 15.0 16.5 2.36 5.91 6.50 2.08 5.20 5.20<br />
Quartet 3.5+3.5+3.5+3.5 14.2 5.60 14.0 14.0 2.02 5.10 5.50 1.91 4.69 4.82<br />
• Heating<br />
Simultaneous<br />
Operation<br />
• Notes<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Combination <strong>of</strong> indoor units<br />
(kW)<br />
Possiblity Total<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Cooling Capacity<br />
Current<br />
Input<br />
Min Rated Max<br />
A<br />
kW<br />
kW kW kW Min Rated Max Min Rated Max<br />
Duo 8.0+8.0 16.0 6.80 17.0 18.2 2.10 5.23 5.75 2.12 5.30 5.70<br />
Trio 5.0+5.0+5.0 15.0 6.80 17.0 18.2 2.31 5.79 6.36 2.08 5.00 5.00<br />
Quartet 3.5+3.5+3.5+3.5 14.2 6.40 16.0 16.0 2.30 5.40 5.90 1.91 4.69 4.82<br />
1. Individual indoor capacities are not given because the combinations are for simultaneous operation.<br />
2. Rated cooling capacities are based on the following conditions:<br />
Indoor air temperature: 27°CDB, 19.0°CWB, outdoor temperature 35°CDB.<br />
Rated heating capacities are based on the following conditions:<br />
Indoor air temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB.<br />
226 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.2.5 Branch kit<br />
Models : PMUB11A, PMUB111A, PMUB1111A<br />
Picture<br />
Features<br />
Connectable <strong>of</strong><br />
indoor units<br />
Between units are the required Branch kits mentioned, that are necessary to install the combination.<br />
Indoor Classification<br />
2 Units<br />
3 Units<br />
4 Units<br />
Models<br />
2 Units PMUB 11A<br />
3 Units<br />
4 Units<br />
(Gas pipe)<br />
(Liquid pipe)<br />
C<br />
A<br />
PMUB 111A<br />
PMUB 1111A<br />
Model Name<br />
PMUB11A<br />
PMUB111A<br />
PMUB1111A<br />
a b c<br />
a b<br />
Type 1 Type 2<br />
B<br />
Gas pipe Liquid pipe<br />
Gas pipe Liquid pipe<br />
D<br />
(1:1) (1:1)<br />
(1:1:1) (1:1:1)<br />
(1:1:1:1) (1:1:1:1)<br />
Capacity Ratio(%)<br />
50:50 (1:1)<br />
33:33:33 (1:1:1)<br />
25:25:25:25(1:1:1:1)<br />
Branch kit<br />
Unit : mm (inch)<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 227<br />
(I.D)<br />
ⓐ ⓑ ⓒ Type<br />
Ⓐ Ø15.88(5/8) Ø19.05(3/4) Ø25.4(1) 1<br />
Ⓑ<br />
Ø9.52(3/8)<br />
Ø12.7(1/2)<br />
Ø12.7(1/2)<br />
Ø15.88(5/8)<br />
- 2<br />
Ⓒ Ø6.35(1/4) Ø9.52(3/8) - 2<br />
Ⓓ Ø9.52(3/8) Ø12.7(1/2) - 2
Piping diagrams 5CSL0-06B<br />
2.2.6 Piping diagrams<br />
Models : "Synchro" Duo - AUUW426D[UU42W U3D], AUUW486D[UU48W U3D], AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D], AUUW488D[UU49W U3D] , AUUW608D[UU61W U3D]<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Fan<br />
Fan<br />
Fan<br />
Fan<br />
Fan<br />
Gas Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Gas Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Gas Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Gas<br />
Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Gas Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Branch kit<br />
(Accessory)<br />
Service Valve<br />
Gas(Ø15.88)<br />
Service Valve<br />
Liquid(Ø9.52)<br />
Branch kit<br />
(Accessory)<br />
Branch kit<br />
(Accessory)<br />
Service Valve<br />
Gas(Ø15.88)<br />
Service Valve<br />
Liquid(Ø9.52)<br />
Branch kit<br />
(Accessory)<br />
Indoor Unit<br />
(kW)<br />
A B<br />
(mm) (mm)<br />
9.52 15.88<br />
9.52 15.88<br />
Note :<br />
1.The pipes between the indoor units and the branch kits must have<br />
same dimensions as indoor unit connections.<br />
OUTDOOR UNIT<br />
Refrigerant Flow<br />
228 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)<br />
E.E.V.<br />
7.1<br />
8.0<br />
Accumulator<br />
r<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
Note :<br />
1.The pipes between the indoor units and the branch kits must have<br />
same dimensions as indoor unit connections.<br />
Th4<br />
Heat<br />
Exchanger<br />
Models : "Synchro" Trio - AUUW426D[UU42W U3D], AUUW486D[UU48W U3D], AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D], AUUW488D[UU49W U3D] , AUUW608D[UU61W U3D]<br />
Thermistor<br />
Thermistor<br />
Thermistor<br />
E.E.V.<br />
Indoor Unit<br />
(kW)<br />
5.0<br />
Accumulator<br />
r<br />
A<br />
(mm)<br />
6.35<br />
B<br />
(mm)<br />
12.7<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
Th3<br />
Cooling<br />
Heating<br />
OUTDOOR UNIT<br />
Th4<br />
Heat<br />
Exchanger<br />
Th3<br />
Refrigerant Flow<br />
Cooling<br />
Heating
5CSL0-06B<br />
Piping diagrams<br />
Models : "Synchro" Quartet - AUUW426D[UU42W U3D], AUUW486D[UU48W U3D], AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D], AUUW488D[UU49W U3D] , AUUW608D[UU61W U3D]<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
INDOOR UNIT<br />
Heat<br />
Exchanger<br />
Thermistor<br />
Fan<br />
Fan<br />
Fan<br />
Fan<br />
Gas<br />
Piping<br />
ØB<br />
Liquid<br />
Piping<br />
ØA<br />
Gas<br />
Piping<br />
ØB<br />
Liquid<br />
Piping<br />
ØA<br />
Gas<br />
Piping<br />
ØB<br />
Liquid<br />
Piping<br />
ØA<br />
Gas Piping<br />
ØB<br />
Liquid Piping<br />
ØA<br />
Branch kit<br />
(Accessory)<br />
Service Valve<br />
Gas(Ø15.88)<br />
Service Valve<br />
Liquid( Ø9.52)<br />
Branch kit<br />
(Accessory)<br />
Indoor Unit<br />
(kW)<br />
Note :<br />
1.The pipes between the indoor units and the branch kits must have<br />
same dimensions as indoor unit connections.<br />
OUTDOOR UNIT<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 229<br />
3.5<br />
E.E.V.<br />
Accumulator<br />
r<br />
A<br />
(mm)<br />
6.35<br />
B<br />
(mm)<br />
9.52<br />
Th1<br />
Th2<br />
Reversing<br />
Valve<br />
Inverter<br />
Compressor<br />
High Pressure<br />
S/W<br />
Th4<br />
Heat<br />
Exchanger<br />
Th3
Capacity tables 5CSL0-06B<br />
2.2.8 Capacity tables<br />
■ Synchro operation (1Φ)<br />
Models : AUUW426D[UU42W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
• Symbol<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 13.73 2.54 13.13 2.65 12.33 3.56 11.95 3.98 11.43 4.37 11.11 4.28 10.80 3.84<br />
16.0 22.0 14.57 3.45 13.97 3.48 13.17 4.20 12.79 4.51 12.26 4.71 11.95 4.48 11.63 3.89<br />
18.0 25.0 15.42 3.72 14.81 3.75 14.00 4.41 13.62 4.60 13.09 4.77 12.78 4.47 12.47 3.79<br />
19.0 27.0 15.84 3.77 15.23 3.80 14.42 4.46 14.00 4.60 13.51 4.78 13.20 4.46 12.88 3.76<br />
22.0 30.0 17.11 3.77 16.49 3.87 15.68 4.57 15.28 4.82 14.76 4.86 14.45 4.51 14.13 3.76<br />
24.0 32.0 17.95 3.74 17.34 3.90 16.51 4.65 16.12 4.92 15.59 4.96 15.28 4.61 14.96 3.85<br />
14.0 20.0 14.71 2.87 14.07 3.00 13.21 4.03 12.81 4.50 12.25 4.94 11.91 4.84 11.57 4.34<br />
16.0 22.0 15.61 3.89 14.97 3.93 14.11 4.75 13.70 5.10 13.14 5.32 12.80 5.06 12.46 4.39<br />
18.0 25.0 16.52 4.21 15.87 4.24 15.00 4.99 14.59 5.20 14.03 5.39 13.69 5.05 13.36 4.29<br />
19.0 27.0 16.97 4.26 16.32 4.30 15.45 5.04 15.00 5.20 14.48 5.41 14.14 5.04 13.80 4.25<br />
22.0 30.0 18.33 4.26 17.67 4.37 16.80 5.16 16.38 5.45 15.81 5.49 15.48 5.09 15.14 4.25<br />
24.0 32.0 19.24 4.23 18.57 4.41 17.69 5.26 17.27 5.56 16.71 5.61 16.37 5.21 16.03 4.35<br />
14.0 20.0 13.73 2.66 13.13 2.78 12.33 3.73 11.95 4.17 11.43 4.58 11.11 4.48 10.80 4.02<br />
16.0 22.0 14.57 3.61 13.97 3.64 13.17 4.40 12.79 4.73 12.26 4.93 11.95 4.69 11.63 4.07<br />
18.0 25.0 15.42 3.90 14.81 3.93 14.00 4.62 13.62 4.82 13.09 5.00 12.78 4.68 12.47 3.98<br />
19.0 27.0 15.84 3.95 15.23 3.98 14.42 4.68 14.00 4.82 13.51 5.01 13.20 4.67 12.88 3.94<br />
22.0 30.0 17.11 3.95 16.49 4.05 15.68 4.79 15.28 5.05 14.76 5.09 14.45 4.72 14.13 3.94<br />
24.0 32.0 17.95 3.92 17.34 4.09 16.51 4.87 16.12 5.15 15.59 5.20 15.28 4.83 14.96 4.03<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 11.39 5.16 12.15 5.26 13.58 5.00 14.93 4.67 16.27 4.40 17.33 4.29 17.79 4.07<br />
18 11.28 5.24 12.13 5.39 13.60 5.14 14.92 4.79 16.15 4.51 17.11 4.38 17.73 4.12<br />
20 11.20 5.34 12.13 5.52 13.60 5.29 14.88 4.92 16.00 4.60 16.99 4.44 17.76 4.14<br />
21 11.17 5.38 12.13 5.60 13.60 5.36 14.85 4.99 15.90 4.65 16.99 4.47 17.65 4.15<br />
22 11.15 5.44 12.13 5.68 13.60 5.44 14.81 5.05 15.78 4.68 16.97 4.49 17.50 4.15<br />
24 11.04 5.54 12.01 5.76 13.44 5.51 14.72 5.10 15.76 4.71 16.69 4.50 17.40 4.17<br />
16 12.10 5.61 12.91 5.72 14.43 5.43 15.87 5.07 17.29 4.78 18.41 4.66 18.90 4.43<br />
18 11.98 5.70 12.89 5.86 14.45 5.59 15.85 5.21 17.16 4.90 18.18 4.76 18.84 4.48<br />
20 11.90 5.80 12.89 6.00 14.45 5.75 15.81 5.35 17.00 5.00 18.06 4.83 18.87 4.50<br />
21 11.87 5.85 12.89 6.09 14.45 5.83 15.78 5.42 16.89 5.05 18.06 4.86 18.75 4.51<br />
22 11.85 5.92 12.89 6.18 14.45 5.91 15.73 5.49 16.77 5.09 18.03 4.88 18.60 4.51<br />
24 11.73 6.02 12.77 6.26 14.28 5.99 15.64 5.54 16.75 5.12 17.74 4.89 18.49 4.53<br />
16 11.39 5.41 12.15 5.51 13.58 5.23 14.93 4.89 16.27 4.61 17.33 4.50 17.79 4.27<br />
18 11.28 5.49 12.13 5.65 13.60 5.39 14.92 5.02 16.15 4.73 17.11 4.58 17.73 4.32<br />
20 11.20 5.59 12.13 5.78 13.60 5.54 14.88 5.16 16.00 4.82 16.99 4.65 17.76 4.34<br />
21 11.17 5.64 12.13 5.87 13.60 5.62 14.85 5.22 15.90 4.87 16.99 4.68 17.65 4.35<br />
22 11.15 5.71 12.13 5.95 13.60 5.70 14.81 5.29 15.78 4.90 16.97 4.71 17.50 4.35<br />
24 11.04 5.80 12.01 6.04 13.44 5.77 14.72 5.34 15.76 4.94 16.69 4.72 17.40 4.37<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
230 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
Models : AUUW486D[UU48W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 14.41 2.79 13.79 2.92 12.94 3.92 12.55 4.37 12.00 4.80 11.67 4.71 11.34 4.22<br />
16.0 22.0 15.30 3.79 14.67 3.82 13.82 4.62 13.42 4.97 12.87 5.18 12.54 4.93 12.21 4.28<br />
18.0 25.0 16.19 4.10 15.55 4.12 14.70 4.85 14.30 5.06 13.75 5.25 13.42 4.92 13.09 4.17<br />
19.0 27.0 16.63 4.14 15.99 4.18 15.14 4.91 14.70 5.06 14.19 5.26 13.86 4.91 13.53 4.13<br />
22.0 30.0 17.96 4.14 17.32 4.25 16.46 5.02 16.05 5.30 15.50 5.35 15.17 4.96 14.84 4.14<br />
24.0 32.0 18.85 4.12 18.20 4.29 17.34 5.12 16.92 5.41 16.37 5.46 16.04 5.07 15.71 4.24<br />
14.0 20.0 15.39 3.16 14.72 3.30 13.83 4.43 13.40 4.95 12.82 5.43 12.46 5.32 12.11 4.77<br />
16.0 22.0 16.34 4.28 15.67 4.32 14.76 5.23 14.34 5.61 13.75 5.85 13.40 5.57 13.05 4.83<br />
18.0 25.0 17.29 4.63 16.61 4.66 15.70 5.49 15.27 5.72 14.68 5.93 14.33 5.56 13.98 4.72<br />
19.0 27.0 17.76 4.68 17.08 4.73 16.17 5.55 15.70 5.72 15.15 5.95 14.80 5.55 14.45 4.67<br />
22.0 30.0 19.19 4.68 18.50 4.81 17.58 5.68 17.14 6.00 16.55 6.04 16.20 5.60 15.85 4.68<br />
24.0 32.0 20.13 4.66 19.44 4.85 18.52 5.78 18.07 6.12 17.49 6.17 17.13 5.73 16.78 4.79<br />
14.0 20.0 14.41 2.66 13.79 2.78 12.94 3.73 12.55 4.17 12.00 4.58 11.67 4.48 11.34 4.02<br />
16.0 22.0 15.30 3.61 14.67 3.64 13.82 4.40 13.42 4.73 12.87 4.93 12.54 4.69 12.21 4.07<br />
18.0 25.0 16.19 3.90 15.55 3.93 14.70 4.62 14.30 4.82 13.75 5.00 13.42 4.68 13.09 3.98<br />
19.0 27.0 16.63 3.95 15.99 3.98 15.14 4.68 14.70 4.82 14.19 5.01 13.86 4.67 13.53 3.94<br />
22.0 30.0 17.96 3.95 17.32 4.05 16.46 4.79 16.05 5.05 15.50 5.09 15.17 4.72 14.84 3.94<br />
24.0 32.0 18.85 3.92 18.20 4.09 17.34 4.87 16.92 5.15 16.37 5.20 16.04 4.83 15.71 4.03<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 11.95 5.68 12.76 5.79 14.26 5.49 15.68 5.13 17.08 4.84 18.19 4.72 18.68 4.48<br />
18 11.84 5.77 12.74 5.93 14.28 5.66 15.67 5.27 16.96 4.96 17.96 4.81 18.62 4.53<br />
20 11.76 5.87 12.74 6.07 14.28 5.82 15.62 5.41 16.80 5.06 17.84 4.88 18.65 4.55<br />
21 11.73 5.92 12.74 6.16 14.28 5.90 15.59 5.48 16.69 5.11 17.84 4.92 18.53 4.56<br />
22 11.71 5.99 12.74 6.25 14.28 5.98 15.55 5.56 16.57 5.15 17.82 4.94 18.38 4.56<br />
24 11.60 6.09 12.62 6.34 14.11 6.06 15.46 5.61 16.55 5.18 17.53 4.95 18.27 4.59<br />
16 12.45 6.18 13.29 6.29 14.85 5.97 16.33 5.58 17.79 5.26 18.95 5.13 19.46 4.87<br />
18 12.34 6.27 13.27 6.44 14.88 6.15 16.32 5.73 17.67 5.39 18.71 5.23 19.39 4.93<br />
20 12.25 6.38 13.27 6.60 14.88 6.33 16.28 5.89 17.50 5.50 18.59 5.31 19.43 4.95<br />
21 12.22 6.44 13.27 6.70 14.88 6.41 16.24 5.96 17.39 5.55 18.59 5.35 19.31 4.96<br />
22 12.20 6.51 13.27 6.79 14.88 6.50 16.19 6.04 17.26 5.59 18.56 5.37 19.15 4.96<br />
24 12.08 6.62 13.14 6.89 14.70 6.59 16.10 6.10 17.24 5.63 18.26 5.38 19.03 4.98<br />
16 11.95 5.49 12.76 5.59 14.26 5.31 15.68 4.96 17.08 4.67 18.19 4.56 18.68 4.33<br />
18 11.84 5.57 12.74 5.73 14.28 5.47 15.67 5.10 16.96 4.79 17.96 4.65 18.62 4.38<br />
20 11.76 5.67 12.74 5.87 14.28 5.62 15.62 5.23 16.80 4.89 17.84 4.72 18.65 4.40<br />
21 11.73 5.72 12.74 5.95 14.28 5.70 15.59 5.30 16.69 4.94 17.84 4.75 18.53 4.41<br />
22 11.71 5.79 12.74 6.04 14.28 5.78 15.55 5.37 16.57 4.97 17.82 4.78 18.38 4.41<br />
24 11.60 5.89 12.62 6.12 14.11 5.86 15.46 5.42 16.55 5.01 17.53 4.79 18.27 4.43<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 231
Models : AUUW606D[UU60W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Temperature<br />
5CSL0-06B<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 16.18 3.20 15.48 3.35 14.53 4.49 14.09 5.01 13.47 5.51 13.10 5.39 12.73 4.84<br />
16.0 22.0 17.17 4.34 16.47 4.38 15.52 5.30 15.07 5.69 14.45 5.93 14.08 5.65 13.71 4.90<br />
18.0 25.0 18.17 4.70 17.46 4.72 16.50 5.56 16.05 5.80 15.43 6.02 15.06 5.64 14.69 4.78<br />
19.0 27.0 18.67 4.75 17.95 4.79 17.00 5.63 16.50 5.80 15.92 6.03 15.55 5.63 15.18 4.74<br />
22.0 30.0 20.16 4.75 19.44 4.87 18.47 5.76 18.01 6.08 17.40 6.13 17.02 5.68 16.65 4.74<br />
24.0 32.0 21.16 4.72 20.43 4.92 19.46 5.87 18.99 6.20 18.38 6.26 18.01 5.81 17.64 4.86<br />
14.0 20.0 16.18 2.87 15.48 3.00 14.53 4.03 14.09 4.50 13.47 4.94 13.10 4.84 12.73 4.34<br />
16.0 22.0 17.17 3.89 16.47 3.93 15.52 4.75 15.07 5.10 14.45 5.32 14.08 5.06 13.71 4.39<br />
18.0 25.0 18.17 4.21 17.46 4.24 16.50 4.99 16.05 5.20 15.43 5.39 15.06 5.05 14.69 4.29<br />
19.0 27.0 18.67 4.26 17.95 4.30 17.00 5.04 16.50 5.20 15.92 5.41 15.55 5.04 15.18 4.25<br />
22.0 30.0 20.16 4.26 19.44 4.37 18.47 5.16 18.01 5.45 17.40 5.49 17.02 5.09 16.65 4.25<br />
24.0 32.0 21.16 4.23 20.43 4.41 19.46 5.26 18.99 5.56 18.38 5.61 18.01 5.21 17.64 4.35<br />
14.0 20.0 15.10 2.66 14.44 2.78 13.56 3.73 13.15 4.17 12.57 4.58 12.23 4.48 11.88 4.02<br />
16.0 22.0 16.03 3.61 15.37 3.64 14.48 4.40 14.06 4.73 13.49 4.93 13.14 4.69 12.80 4.07<br />
18.0 25.0 16.96 3.90 16.29 3.93 15.40 4.62 14.98 4.82 14.40 5.00 14.06 4.68 13.71 3.98<br />
19.0 27.0 17.42 3.95 16.76 3.98 15.86 4.68 15.40 4.82 14.86 5.01 14.52 4.67 14.17 3.94<br />
22.0 30.0 18.82 3.95 18.14 4.05 17.24 4.79 16.81 5.05 16.24 5.09 15.89 4.72 15.54 3.94<br />
24.0 32.0 19.75 3.92 19.07 4.09 18.16 4.87 17.73 5.15 17.15 5.20 16.81 4.83 16.46 4.03<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.95 6.40 13.82 6.52 15.45 6.19 16.99 5.78 18.51 5.45 19.71 5.32 20.24 5.05<br />
18 12.83 6.50 13.80 6.68 15.47 6.37 16.97 5.94 18.38 5.59 19.46 5.42 20.17 5.11<br />
20 12.74 6.61 13.80 6.84 15.47 6.56 16.93 6.10 18.20 5.70 19.33 5.50 20.20 5.13<br />
21 12.71 6.67 13.80 6.94 15.47 6.65 16.89 6.18 18.08 5.76 19.33 5.54 20.08 5.14<br />
22 12.68 6.75 13.80 7.04 15.47 6.74 16.84 6.26 17.95 5.80 19.31 5.57 19.91 5.14<br />
24 12.56 6.86 13.67 7.14 15.28 6.83 16.75 6.32 17.93 5.84 18.99 5.58 19.80 5.16<br />
16 12.95 5.61 13.82 5.72 15.45 5.43 16.99 5.07 18.51 4.78 19.71 4.66 20.24 4.43<br />
18 12.83 5.70 13.80 5.86 15.47 5.59 16.97 5.21 18.38 4.90 19.46 4.76 20.17 4.48<br />
20 12.74 5.80 13.80 6.00 15.47 5.75 16.93 5.35 18.20 5.00 19.33 4.83 20.20 4.50<br />
21 12.71 5.85 13.80 6.09 15.47 5.83 16.89 5.42 18.08 5.05 19.33 4.86 20.08 4.51<br />
22 12.68 5.92 13.80 6.18 15.47 5.91 16.84 5.49 17.95 5.09 19.31 4.88 19.91 4.51<br />
24 12.56 6.02 13.67 6.26 15.28 5.99 16.75 5.54 17.93 5.12 18.99 4.89 19.80 4.53<br />
16 12.52 5.49 13.37 5.59 14.94 5.31 16.43 4.96 17.90 4.67 19.06 4.56 19.57 4.33<br />
18 12.41 5.57 13.35 5.73 14.96 5.47 16.41 5.10 17.77 4.79 18.82 4.65 19.50 4.38<br />
20 12.32 5.67 13.35 5.87 14.96 5.62 16.37 5.23 17.60 4.89 18.69 4.72 19.54 4.40<br />
21 12.29 5.72 13.35 5.95 14.96 5.70 16.33 5.30 17.49 4.94 18.69 4.75 19.42 4.41<br />
22 12.27 5.79 13.35 6.04 14.96 5.78 16.29 5.37 17.36 4.97 18.67 4.78 19.25 4.41<br />
24 12.15 5.89 13.22 6.12 14.78 5.86 16.19 5.42 17.34 5.01 18.36 4.79 19.14 4.43<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
232 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW428D[UU43W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 13.73 2.54 13.13 2.65 12.33 3.56 11.95 3.98 11.43 4.37 11.11 4.28 10.80 3.84<br />
16.0 22.0 14.57 3.45 13.97 3.48 13.17 4.20 12.79 4.51 12.26 4.71 11.95 4.48 11.63 3.89<br />
18.0 25.0 15.42 3.72 14.81 3.75 14.00 4.41 13.62 4.60 13.09 4.77 12.78 4.47 12.47 3.79<br />
19.0 27.0 15.84 3.77 15.23 3.80 14.42 4.46 14.00 4.60 13.51 4.78 13.20 4.46 12.88 3.76<br />
22.0 30.0 17.11 3.77 16.49 3.87 15.68 4.57 15.28 4.82 14.76 4.86 14.45 4.51 14.13 3.76<br />
24.0 32.0 17.95 3.74 17.34 3.90 16.51 4.65 16.12 4.92 15.59 4.96 15.28 4.61 14.96 3.85<br />
14.0 20.0 14.71 2.87 14.07 3.00 13.21 4.03 12.81 4.50 12.25 4.94 11.91 4.84 11.57 4.34<br />
16.0 22.0 15.61 3.89 14.97 3.93 14.11 4.75 13.70 5.10 13.14 5.32 12.80 5.06 12.46 4.39<br />
18.0 25.0 16.52 4.21 15.87 4.24 15.00 4.99 14.59 5.20 14.03 5.39 13.69 5.05 13.36 4.29<br />
19.0 27.0 16.97 4.26 16.32 4.30 15.45 5.04 15.00 5.20 14.48 5.41 14.14 5.04 13.80 4.25<br />
22.0 30.0 18.33 4.26 17.67 4.37 16.80 5.16 16.38 5.45 15.81 5.49 15.48 5.09 15.14 4.25<br />
24.0 32.0 19.24 4.23 18.57 4.41 17.69 5.26 17.27 5.56 16.71 5.61 16.37 5.21 16.03 4.35<br />
14.0 20.0 13.73 2.66 13.13 2.78 12.33 3.73 11.95 4.17 11.43 4.58 11.11 4.48 10.80 4.02<br />
16.0 22.0 14.57 3.61 13.97 3.64 13.17 4.40 12.79 4.73 12.26 4.93 11.95 4.69 11.63 4.07<br />
18.0 25.0 15.42 3.90 14.81 3.93 14.00 4.62 13.62 4.82 13.09 5.00 12.78 4.68 12.47 3.98<br />
19.0 27.0 15.84 3.95 15.23 3.98 14.42 4.68 14.00 4.82 13.51 5.01 13.20 4.67 12.88 3.94<br />
22.0 30.0 17.11 3.95 16.49 4.05 15.68 4.79 15.28 5.05 14.76 5.09 14.45 4.72 14.13 3.94<br />
24.0 32.0 17.95 3.92 17.34 4.09 16.51 4.87 16.12 5.15 15.59 5.20 15.28 4.83 14.96 4.03<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 11.39 5.16 12.15 5.26 13.58 5.00 14.93 4.67 16.27 4.40 17.33 4.29 17.79 4.07<br />
18 11.28 5.24 12.13 5.39 13.60 5.14 14.92 4.79 16.15 4.51 17.11 4.38 17.73 4.12<br />
20 11.20 5.34 12.13 5.52 13.60 5.29 14.88 4.92 16.00 4.60 16.99 4.44 17.76 4.14<br />
21 11.17 5.38 12.13 5.60 13.60 5.36 14.85 4.99 15.90 4.65 16.99 4.47 17.65 4.15<br />
22 11.15 5.44 12.13 5.68 13.60 5.44 14.81 5.05 15.78 4.68 16.97 4.49 17.50 4.15<br />
24 11.04 5.54 12.01 5.76 13.44 5.51 14.72 5.10 15.76 4.71 16.69 4.50 17.40 4.17<br />
16 12.10 5.61 12.91 5.72 14.43 5.43 15.87 5.07 17.29 4.78 18.41 4.66 18.90 4.43<br />
18 11.98 5.70 12.89 5.86 14.45 5.59 15.85 5.21 17.16 4.90 18.18 4.76 18.84 4.48<br />
20 11.90 5.80 12.89 6.00 14.45 5.75 15.81 5.35 17.00 5.00 18.06 4.83 18.87 4.50<br />
21 11.87 5.85 12.89 6.09 14.45 5.83 15.78 5.42 16.89 5.05 18.06 4.86 18.75 4.51<br />
22 11.85 5.92 12.89 6.18 14.45 5.91 15.73 5.49 16.77 5.09 18.03 4.88 18.60 4.51<br />
24 11.73 6.02 12.77 6.26 14.28 5.99 15.64 5.54 16.75 5.12 17.74 4.89 18.49 4.53<br />
16 11.39 5.41 12.15 5.51 13.58 5.23 14.93 4.89 16.27 4.61 17.33 4.50 17.79 4.27<br />
18 11.28 5.49 12.13 5.65 13.60 5.39 14.92 5.02 16.15 4.73 17.11 4.58 17.73 4.32<br />
20 11.20 5.59 12.13 5.78 13.60 5.54 14.88 5.16 16.00 4.82 16.99 4.65 17.76 4.34<br />
21 11.17 5.64 12.13 5.87 13.60 5.62 14.85 5.22 15.90 4.87 16.99 4.68 17.65 4.35<br />
22 11.15 5.71 12.13 5.95 13.60 5.70 14.81 5.29 15.78 4.90 16.97 4.71 17.50 4.35<br />
24 11.04 5.80 12.01 6.04 13.44 5.77 14.72 5.34 15.76 4.94 16.69 4.72 17.40 4.37<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 233
Models : AUUW488D[UU49W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Temperature<br />
5CSL0-06B<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 14.41 2.79 13.79 2.92 12.94 3.92 12.55 4.37 12.00 4.80 11.67 4.71 11.34 4.22<br />
16.0 22.0 15.30 3.79 14.67 3.82 13.82 4.62 13.42 4.97 12.87 5.18 12.54 4.93 12.21 4.28<br />
18.0 25.0 16.19 4.10 15.55 4.12 14.70 4.85 14.30 5.06 13.75 5.25 13.42 4.92 13.09 4.17<br />
19.0 27.0 16.63 4.14 15.99 4.18 15.14 4.91 14.70 5.06 14.19 5.26 13.86 4.91 13.53 4.13<br />
22.0 30.0 17.96 4.14 17.32 4.25 16.46 5.02 16.05 5.30 15.50 5.35 15.17 4.96 14.84 4.14<br />
24.0 32.0 18.85 4.12 18.20 4.29 17.34 5.12 16.92 5.41 16.37 5.46 16.04 5.07 15.71 4.24<br />
14.0 20.0 15.39 3.16 14.72 3.30 13.83 4.43 13.40 4.95 12.82 5.43 12.46 5.32 12.11 4.77<br />
16.0 22.0 16.34 4.28 15.67 4.32 14.76 5.23 14.34 5.61 13.75 5.85 13.40 5.57 13.05 4.83<br />
18.0 25.0 17.29 4.63 16.61 4.66 15.70 5.49 15.27 5.72 14.68 5.93 14.33 5.56 13.98 4.72<br />
19.0 27.0 17.76 4.68 17.08 4.73 16.17 5.55 15.70 5.72 15.15 5.95 14.80 5.55 14.45 4.67<br />
22.0 30.0 19.19 4.68 18.50 4.81 17.58 5.68 17.14 6.00 16.55 6.04 16.20 5.60 15.85 4.68<br />
24.0 32.0 20.13 4.66 19.44 4.85 18.52 5.78 18.07 6.12 17.49 6.17 17.13 5.73 16.78 4.79<br />
14.0 20.0 14.41 2.83 13.79 2.95 12.94 3.97 12.55 4.43 12.00 4.86 11.67 4.76 11.34 4.27<br />
16.0 22.0 15.30 3.83 14.67 3.87 13.82 4.68 13.42 5.03 12.87 5.24 12.54 4.98 12.21 4.33<br />
18.0 25.0 16.19 4.15 15.55 4.17 14.70 4.91 14.30 5.12 13.75 5.31 13.42 4.98 13.09 4.22<br />
19.0 27.0 16.63 4.19 15.99 4.23 15.14 4.97 14.70 5.12 14.19 5.33 13.86 4.97 13.53 4.18<br />
22.0 30.0 17.96 4.19 17.32 4.30 16.46 5.08 16.05 5.37 15.50 5.41 15.17 5.01 14.84 4.19<br />
24.0 32.0 18.85 4.17 18.20 4.34 17.34 5.18 16.92 5.48 16.37 5.52 16.04 5.13 15.71 4.29<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 11.95 5.68 12.76 5.79 14.26 5.49 15.68 5.13 17.08 4.84 18.19 4.72 18.68 4.48<br />
18 11.84 5.77 12.74 5.93 14.28 5.66 15.67 5.27 16.96 4.96 17.96 4.81 18.62 4.53<br />
20 11.76 5.87 12.74 6.07 14.28 5.82 15.62 5.41 16.80 5.06 17.84 4.88 18.65 4.55<br />
21 11.73 5.92 12.74 6.16 14.28 5.90 15.59 5.48 16.69 5.11 17.84 4.92 18.53 4.56<br />
22 11.71 5.99 12.74 6.25 14.28 5.98 15.55 5.56 16.57 5.15 17.82 4.94 18.38 4.56<br />
24 11.60 6.09 12.62 6.34 14.11 6.06 15.46 5.61 16.55 5.18 17.53 4.95 18.27 4.59<br />
16 12.45 6.18 13.29 6.29 14.85 5.97 16.33 5.58 17.79 5.26 18.95 5.13 19.46 4.87<br />
18 12.34 6.27 13.27 6.44 14.88 6.15 16.32 5.73 17.67 5.39 18.71 5.23 19.39 4.93<br />
20 12.25 6.38 13.27 6.60 14.88 6.33 16.28 5.89 17.50 5.50 18.59 5.31 19.43 4.95<br />
21 12.22 6.44 13.27 6.70 14.88 6.41 16.24 5.96 17.39 5.55 18.59 5.35 19.31 4.96<br />
22 12.20 6.51 13.27 6.79 14.88 6.50 16.19 6.04 17.26 5.59 18.56 5.37 19.15 4.96<br />
24 12.08 6.62 13.14 6.89 14.70 6.59 16.10 6.10 17.24 5.63 18.26 5.38 19.03 4.98<br />
16 11.95 5.86 12.76 5.97 14.26 5.67 15.68 5.29 17.08 4.99 18.19 4.87 18.68 4.62<br />
18 11.84 5.95 12.74 6.12 14.28 5.84 15.67 5.44 16.96 5.12 17.96 4.97 18.62 4.68<br />
20 11.76 6.06 12.74 6.26 14.28 6.00 15.62 5.59 16.80 5.22 17.84 5.04 18.65 4.70<br />
21 11.73 6.11 12.74 6.36 14.28 6.09 15.59 5.66 16.69 5.27 17.84 5.07 18.53 4.71<br />
22 11.71 6.18 12.74 6.45 14.28 6.17 15.55 5.73 16.57 5.31 17.82 5.10 18.38 4.71<br />
24 11.60 6.28 12.62 6.54 14.11 6.25 15.46 5.79 16.55 5.35 17.53 5.11 18.27 4.73<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
234 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
Models : AUUW608D[UU61W U3D]<br />
• Cooling Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43 46<br />
°CWB °CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
14.0 20.0 16.18 3.20 15.48 3.35 14.53 4.49 14.09 5.01 13.47 5.51 13.10 5.39 12.73 4.84<br />
16.0 22.0 17.17 4.34 16.47 4.38 15.52 5.30 15.07 5.69 14.45 5.93 14.08 5.65 13.71 4.90<br />
18.0 25.0 18.17 4.70 17.46 4.72 16.50 5.56 16.05 5.80 15.43 6.02 15.06 5.64 14.69 4.78<br />
19.0 27.0 18.67 4.75 17.95 4.79 17.00 5.63 16.50 5.80 15.92 6.03 15.55 5.63 15.18 4.74<br />
22.0 30.0 20.16 4.75 19.44 4.87 18.47 5.76 18.01 6.08 17.40 6.13 17.02 5.68 16.65 4.74<br />
24.0 32.0 21.16 4.72 20.43 4.92 19.46 5.87 18.99 6.20 18.38 6.26 18.01 5.81 17.64 4.86<br />
14.0 20.0 16.18 2.87 15.48 3.00 14.53 4.03 14.09 4.50 13.47 4.94 13.10 4.84 12.73 4.34<br />
16.0 22.0 17.17 3.89 16.47 3.93 15.52 4.75 15.07 5.10 14.45 5.32 14.08 5.06 13.71 4.39<br />
18.0 25.0 18.17 4.21 17.46 4.24 16.50 4.99 16.05 5.20 15.43 5.39 15.06 5.05 14.69 4.29<br />
19.0 27.0 18.67 4.26 17.95 4.30 17.00 5.04 16.50 5.20 15.92 5.41 15.55 5.04 15.18 4.25<br />
22.0 30.0 20.16 4.26 19.44 4.37 18.47 5.16 18.01 5.45 17.40 5.49 17.02 5.09 16.65 4.25<br />
24.0 32.0 21.16 4.23 20.43 4.41 19.46 5.26 18.99 5.56 18.38 5.61 18.01 5.21 17.64 4.35<br />
14.0 20.0 13.73 2.66 13.13 2.78 12.33 3.73 11.95 4.17 11.43 4.58 11.11 4.48 10.80 4.02<br />
16.0 22.0 14.57 3.61 13.97 3.64 13.17 4.40 12.79 4.73 12.26 4.93 11.95 4.69 11.63 4.07<br />
18.0 25.0 15.42 3.90 14.81 3.93 14.00 4.62 13.62 4.82 13.09 5.00 12.78 4.68 12.47 3.98<br />
19.0 27.0 15.84 3.95 15.23 3.98 14.42 4.68 14.00 4.82 13.51 5.01 13.20 4.67 12.88 3.94<br />
22.0 30.0 17.11 3.95 16.49 4.05 15.68 4.79 15.28 5.05 14.76 5.09 14.45 4.72 14.13 3.94<br />
24.0 32.0 17.95 3.92 17.34 4.09 16.51 4.87 16.12 5.15 15.59 5.20 15.28 4.83 14.96 4.03<br />
• Heating Capacity<br />
Simultaneous<br />
Operation<br />
Duo<br />
Trio<br />
Quartet<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature -15 -10 -5 0 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16 12.95 6.40 13.82 6.52 15.45 6.19 16.99 5.78 18.51 5.45 19.71 5.32 20.24 5.05<br />
18 12.83 6.50 13.80 6.68 15.47 6.37 16.97 5.94 18.38 5.59 19.46 5.42 20.17 5.11<br />
20 12.74 6.61 13.80 6.84 15.47 6.56 16.93 6.10 18.20 5.70 19.33 5.50 20.20 5.13<br />
21 12.71 6.67 13.80 6.94 15.47 6.65 16.89 6.18 18.08 5.76 19.33 5.54 20.08 5.14<br />
22 12.68 6.75 13.80 7.04 15.47 6.74 16.84 6.26 17.95 5.80 19.31 5.57 19.91 5.14<br />
24 12.56 6.86 13.67 7.14 15.28 6.83 16.75 6.32 17.93 5.84 18.99 5.58 19.80 5.16<br />
16 12.95 5.61 13.82 5.72 15.45 5.43 16.99 5.07 18.51 4.78 19.71 4.66 20.24 4.43<br />
18 12.83 5.70 13.80 5.86 15.47 5.59 16.97 5.21 18.38 4.90 19.46 4.76 20.17 4.48<br />
20 12.74 5.80 13.80 6.00 15.47 5.75 16.93 5.35 18.20 5.00 19.33 4.83 20.20 4.50<br />
21 12.71 5.85 13.80 6.09 15.47 5.83 16.89 5.42 18.08 5.05 19.33 4.86 20.08 4.51<br />
22 12.68 5.92 13.80 6.18 15.47 5.91 16.84 5.49 17.95 5.09 19.31 4.88 19.91 4.51<br />
24 12.56 6.02 13.67 6.26 15.28 5.99 16.75 5.54 17.93 5.12 18.99 4.89 19.80 4.53<br />
16 11.39 5.41 12.15 5.51 13.58 5.23 14.93 4.89 16.27 4.61 17.33 4.50 17.79 4.27<br />
18 11.28 5.49 12.13 5.65 13.60 5.39 14.92 5.02 16.15 4.73 17.11 4.58 17.73 4.32<br />
20 11.20 5.59 12.13 5.78 13.60 5.54 14.88 5.16 16.00 4.82 16.99 4.65 17.76 4.34<br />
21 11.17 5.64 12.13 5.87 13.60 5.62 14.85 5.22 15.90 4.87 16.99 4.68 17.65 4.35<br />
22 11.15 5.71 12.13 5.95 13.60 5.70 14.81 5.29 15.78 4.90 16.97 4.71 17.50 4.35<br />
24 11.04 5.80 12.01 6.04 13.44 5.77 14.72 5.34 15.76 4.94 16.69 4.72 17.40 4.37<br />
• Symbol<br />
TC : Total capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. Indicates rated capacity.<br />
2. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 235
Capacity coefficient factor (Reference) 5CSL0-06B<br />
2.2.9 Capacity coefficient factor (Reference)<br />
1) Rate <strong>of</strong> Change in Capacity by the Main Piping Length<br />
DC Inverter Synchro.(1Ø, 3Ø)<br />
Rate <strong>of</strong> Change in Cooling Capacity Rate <strong>of</strong> Change in Heating Capacity<br />
HL<br />
(m)<br />
HU<br />
(m)<br />
45<br />
30<br />
15<br />
0<br />
0<br />
15<br />
30<br />
45<br />
0.97<br />
0.93<br />
0.90<br />
0.85 0.81 0.80<br />
0 15 30 45 60 75 80 90<br />
0.97<br />
0.93<br />
0.90<br />
0.85 0.81 0.80<br />
Description <strong>of</strong> symbols:<br />
HL : Level difference(m) between outdoor and indoor units where indoor units are at alower position.<br />
HU : Level difference(m) between outdoor and indoor units where indoor units are in an upper position.<br />
L : Equivalent piping length(m)<br />
δ : Capacity correction factor<br />
• Notes<br />
δ<br />
δ<br />
236 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)<br />
HL<br />
(m)<br />
HU<br />
(m)<br />
45<br />
30<br />
15<br />
0<br />
0<br />
15<br />
30<br />
45<br />
0.99<br />
0.97<br />
0.96<br />
0.94 0.93 0.92<br />
0 15 30 45 60 75 80 90<br />
0.99<br />
0.97<br />
0.96<br />
0.94 0.93 0.92<br />
1. These figures shows the rate change in capacity <strong>of</strong> a standard indoor unit system at max. load (with the thermostat set to<br />
the max.) under the standard conditions.<br />
2. With this outdoor unit during cooling operation, the evaporating temperature is controlled to be constant and during<br />
heating condensing temperature is controlled to be constant.<br />
3. Method <strong>of</strong> calculating the cooling/heating capacity (max. capacity for combination with the standard indoor unit)<br />
Cooling/Heating capacity = Cooling/Heating capacity obtained from the performance characteristics table x each capacity<br />
rate <strong>of</strong> change.<br />
When the piping length is different depending upon the indoor unit, the max. capacity <strong>of</strong> each unit during simultaneous<br />
operation is as follows.<br />
Cooling/Heating Capacity = Cooling/Heating Capacity <strong>of</strong> each unit x capacity rate <strong>of</strong> change for each piping length<br />
4. Even thogh there are over-height, over-length that we guarantee, pipe length and height are followed by each<br />
specification allowed.<br />
δ<br />
δ
5CSL0-06B<br />
2) Rate <strong>of</strong> Change in Capacity by the Branch Piping Length<br />
3.5 kW models 5.0 kW models<br />
Piping Rate <strong>of</strong> Change in Capacity<br />
Length Cooling Heating<br />
5 100.00% 100.00%<br />
10 97.00% 98.30%<br />
15 94.00% 96.50%<br />
7.1 kW models<br />
Piping Rate <strong>of</strong> Change in Capacity<br />
Length Cooling Heating<br />
5 100.00% 100.00%<br />
10 97.80% 99.20%<br />
15 95.50% 98.40%<br />
Capacity coefficient factor (Reference)<br />
Piping Rate <strong>of</strong> Change in Capacity<br />
Length Cooling Heating<br />
5 100.00% 100.00%<br />
10 98.30% 99.50%<br />
15 96.50% 99.00%<br />
8.0 kW models<br />
Piping Rate <strong>of</strong> Change in Capacity<br />
Length Cooling Heating<br />
5 100.00% 100.00%<br />
10 98.40% 99.10%<br />
15 96.80% 98.20%<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 237
Capacity coefficient factor (Reference) 5CSL0-06B<br />
3) Calculation <strong>of</strong> actual system capacity<br />
① Outdoor unit rated capacity<br />
Qodu(rated) [from specification table]<br />
② Outdoor unit capacity at Ti, To temperature.<br />
Qodu(Ti, To) [from capacity table]<br />
③ Outdoor unit capacity coefficient factor<br />
F(Ti, To) = Qodu(Ti, To) / Qodu(rated)<br />
④ Piping correction factor [from capacity coefficient factor table]<br />
Fmain (length, elevation) for main piping length or elevation<br />
Fbranch (length, elevation) for branch piping length or elevation<br />
⑤ Individual indoor unit combinational capacity<br />
Qidu (combi) = Qodu(rated) x Qidu(rated) / Qidu(rated-total)<br />
⑥ Individual indoor unit actual capacity<br />
Qidu (actual) = Qodu(combi) x F(Ti, To) x Fmain (length, elevation) x Fbranch (length, elevation)<br />
Exam<strong>pl</strong>e) • Outdoor unit model : AUUW486D[UU48W U3D]<br />
• Total indoor units combination : UT24 + UT24<br />
• Outdoor temperature : 32.0°CDB<br />
• Indoor temperature: 19.0°WDB<br />
• Main piping length(O/D to BD):40m<br />
• Branch piping length(BD to I/D):10m<br />
• Indoor unit actual cooling capacity<br />
- Qodu(rated) : 14.0 kW<br />
- Qodu(Ti, To) : 14.4 kW<br />
- F(Ti, To) : 14.4 / 14.0 = 1.03%<br />
- Fmain (length, elevation) = 91.1%<br />
- Fbranch (length, elevation) = 97.8%<br />
- Qidu(actual) [UT24 + UT24] = 14.0 kW x 1.03 x 0.911 x 0.978 = 12.85kW<br />
238 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.2.10 Operation range<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
46<br />
43<br />
21<br />
-5<br />
-10<br />
Cooling<br />
Operative<br />
Continuous<br />
operation<br />
18 32<br />
Indoor Unit [°C DB]<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
Operation limit<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 239<br />
24<br />
-10<br />
-15<br />
Warming up<br />
Operation<br />
Heating<br />
Continuous<br />
operation<br />
Operative<br />
16 30<br />
Indoor Unit [°C DB]<br />
Operative: Intermittent operation due to the operational<br />
conditions (indoor/outdoor temperature,<br />
humidity, load etc.) can cause the heating<br />
capacity to decrease
Electric Characteristics 5CSL0-06B<br />
2.2.11 Electric Characteristics<br />
Unit<br />
Power Compressor OFM<br />
Model Type Hz Voltage Voltage range MCA MOP MSC RLA kW FLA<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
1 Phase<br />
inverter<br />
3 Phase<br />
inverter<br />
50<br />
50<br />
220-240<br />
380-415<br />
Notes :<br />
1. Voltage range<br />
Voltage sup<strong>pl</strong>ied to the unit terminals should be within the<br />
minimum and maximum range<br />
2. Maximum allowable voltage unbalance between phase is 2 %<br />
3. MCA / MOP<br />
MCA = (1.25 x Load1) + Load2 + Load3<br />
MOP = (2.25 x Load1) + Load2 + Load3<br />
- Load1 : Rated running current <strong>of</strong> largest motor<br />
(compressor or other motor)<br />
- Load2 : sum <strong>of</strong> current for all other motors<br />
- Load3 : any other load rated 1.0A or more<br />
4. Select wire spec. based on the MCA<br />
5. Recommended circuit breaker is ELCB (Earth Leakage circuit<br />
breaker)<br />
6. MSC & RLA are measured as the compressor only test<br />
condition.<br />
7. MSC values<br />
Min.: 198<br />
Max.: 264<br />
Min.: 352<br />
Maxi.: 457<br />
22.45 39.45 14.20 17.00 0.24 1.20<br />
26.20 46.20 14.20 20.00 0.24 1.20<br />
31.83 56.33 14.20 24.50 0.24 1.20<br />
6.55 10.83 4.28 4.28 0.24 1.20<br />
7.74 12.97 5.23 5.23 0.24 1.20<br />
8.59 14.50 5.91 5.91 0.24 1.20<br />
8. RLA is measured during each individual compressor test<br />
condition.<br />
9. OFM is measured as the outdoor unit test condition<br />
(Exam<strong>pl</strong>e) Selection <strong>of</strong> proper circuit breaker<br />
① Model : AUUW486D<br />
- Rated running current : 20.0A (refer to spec. sheet)<br />
② MCA = (1.25 x Load1) + Load2 + Load3<br />
= (1.25 x 20.0) + 0 + 1.20 = 26.2A<br />
③ MOP = (2.25 x Load1) + Load2 + Load3<br />
= (2.25 x 20.0) + 0 + 1.20 = 46.2A<br />
→ Finally select circuit breaker 50A<br />
MCA : Minimum Circuit Amperes (A)<br />
MOP : Maximum rating over current protective device<br />
MSC : Maximum Starting Current<br />
RLA : Rated Load Amperes (A)<br />
OFM : Outdoor Fan Motor<br />
kW : Fan Motor rated output (kW)<br />
FLA : Full Load Amperes (A)<br />
240 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.2.12 Field wiring diagrams<br />
DC Inverter Synchro(1Ø)<br />
1. All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
2. Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the current as required by the air conditioner.<br />
3. Feed the power source to the unit via a distribution switch board designed for this purpose.<br />
4. The terminal screws inside the control box may be loose due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can overload and damage electrical components.)<br />
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.<br />
L<br />
N<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
Circuit breaker<br />
Power cable 3 core 5.0mm 2<br />
(Including earth)<br />
Fuse<br />
L<br />
N<br />
G<br />
Outdoor unit<br />
Terminal Block outdoor<br />
1(L) 2(N) 1(L) 2(N) 3<br />
Notes:<br />
1. All wirings, components and materials to be procured on the site should be according to the standard<br />
2. Use copper conductor only<br />
3. Install circuit breaker for safety<br />
4. Unit should be grounded in com<strong>pl</strong>iance with the ap<strong>pl</strong>icable local and national codes<br />
5. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Field wiring diagrams<br />
Transmission line<br />
1(L) 2(N) 3 1(L) 2(N) 3 1(L) 2(N) 3 1(L) 2(N) 3<br />
Terminal block indoor<br />
Terminal block indoor<br />
Terminal block indoor<br />
Terminal block indoor<br />
A unit B unit C unit D unit<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 241
Field wiring diagrams 5CSL0-06B<br />
DC Inverter Synchro(3Ø)<br />
1. All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
2. Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the current as required by the air conditioner.<br />
3. Feed the power source to the unit via a distribution switch board designed for this purpose.<br />
4. The terminal screws inside the control box may be loose due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can overload and damage electrical components.)<br />
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.<br />
R<br />
S<br />
T N<br />
Circuit breaker<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
Fuse<br />
Power cable 5 core x 2.5mm 2<br />
(Including earth)<br />
R<br />
S<br />
T N<br />
Outdoor unit<br />
Terminal Block outdoor<br />
R S T N 1(L) 2(N) 3 4 5<br />
Notes:<br />
1. All wirings, components and materials to be procured on the site should be according to the standard<br />
2. Use copper conductor only<br />
3. Install circuit breaker for safety<br />
4. Unit should be grounded in com<strong>pl</strong>iance with the ap<strong>pl</strong>icable local and national codes<br />
5. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Transmission<br />
cable<br />
1(L) 2(N) 3 1(L) 2(N) 3 1(L) 2(N) 3 1(L) 2(N) 3<br />
Terminal block indoor<br />
Terminal block indoor<br />
Terminal block indoor<br />
Terminal block indoor<br />
A unit B unit C unit D unit<br />
242 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.2.13 Sound levels<br />
Sound Pressure Level (dB re 20μPa )<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
D<br />
1m<br />
1m<br />
15m<br />
Sound pressure level<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU48W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Sound levels<br />
Notes:<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as the<br />
construction(acoustic absorption coefficient) <strong>of</strong> particular room in<br />
which the equipment is installed.<br />
- The operating conditions are assumed to be standard<br />
Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø) 243
Accessories 5CSL0-06B<br />
2.2.14 Accessories<br />
Optional accessories<br />
Name Model No. Indoor classification Capacity Ratio(%)<br />
PMUB11A "Synchro" Duo 50:50(1:1)<br />
Branch Kit PMUB111A "Synchro" Trio 33:33:33(1:1:1)<br />
PMUB1111A "Synchro" Quartet 25:25:25:25(1:1:1:1)<br />
244 Outdoor unit - DC Inverter SINGLE A - Synchro (1Ø, 3Ø)
5CSL0-06B<br />
2.3 Non inverter Single A (1Ø, 3Ø)<br />
2.3.1 Power sup<strong>pl</strong>y<br />
External wiring procedure<br />
Power sup<strong>pl</strong>y<br />
Type Outdoor unit Capacity (kW) Circuit breaker capacity Power sup<strong>pl</strong>y<br />
AUUH126D[UU12 ULD]<br />
AUUH186D[UU18 UED]<br />
AUUH246D[UU24 UED]<br />
3.5<br />
5.0<br />
7.1<br />
15A<br />
20A<br />
1Ø, 220-240 V, 50Hz<br />
Heat pump AUUH306D[UU30 UED] 8.0 30A<br />
AUUH368D[UU37 UED] 10.0 25A<br />
AUUH488D[UU48 U3D] 14.0 30A 3Ø, 380V-415V, 50Hz<br />
AUUH608D[UU60 U3D] 15.0 30A<br />
- The power sup<strong>pl</strong>y work is needed only to the outdoor unit. The power sup<strong>pl</strong>y to the indoor unit is conducted through the<br />
transmission wiring.<br />
- Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Circuit breaker<br />
Power sup<strong>pl</strong>y<br />
Earth<br />
Outdoor unit<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 245
List <strong>of</strong> functions 5CSL0-06B<br />
2.3.2 List <strong>of</strong> functions<br />
Non inverter Single A (1Ø, 3Ø)<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Auto operation(Artificial intelligence)<br />
Convenience<br />
Auto Restart Operation<br />
Central control(LGAP)<br />
CAC Network<br />
PDI(Power Distribution Indicator)<br />
Function<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
Category<br />
Function<br />
Defrost / Deicing<br />
High Pressure Switch<br />
Low Pressure Switch<br />
Reliability Phase protection<br />
Restart Delay (3-minutes)<br />
Self Diagnosis<br />
S<strong>of</strong>t Start<br />
Test Function<br />
Auto operation(Artificial intelligence)<br />
Convenience<br />
Auto Restart Operation<br />
Central control(LGAP)<br />
CAC Network<br />
PDI(Power Distribution Indicator)<br />
Function<br />
PI485<br />
Special<br />
Low Ambient Kit<br />
Function Kit<br />
Others Thermistor<br />
AUUH126D<br />
[UU12 ULD]<br />
AUUH186D<br />
[UU18 UED]<br />
AUUH246D<br />
[UU24 UED]<br />
O O O O<br />
- - O O<br />
- - - -<br />
- - - -<br />
O O O O<br />
O O O O<br />
- - - -<br />
O O O O<br />
O O O O<br />
O O O O<br />
O O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O(program logic) AQLA AQLA O(program logic)<br />
- - - -<br />
AUUH368D<br />
[UU37 UED]<br />
AUUH488D<br />
[UU48 U3D]<br />
AUUH306D<br />
[UU30 UED]<br />
O O O<br />
O O O<br />
- O O<br />
O O O<br />
O O O<br />
O O O<br />
- - -<br />
O O O<br />
O O O<br />
O O O<br />
O O O<br />
PQNFG00A0 PQNFG00A0 PQNFG00A0<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
O(program logic) O(program logic) O(program logic)<br />
- - -<br />
AUUH608D<br />
[UU60 U3D]<br />
• O: Ap<strong>pl</strong>ied, • X: Not ap<strong>pl</strong>ied, • - : No relation,<br />
• Option: Model name & price are different according to options, and assembled in factory with main unit.<br />
• Accessory: Installed at field, ordered and purchased separately by the corresponding model name, sup<strong>pl</strong>ied with separate package.<br />
246 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B<br />
2.3.3 Specifications<br />
Specifications<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
ATNH12GRLED ATNH18GQLED ATNH24GPLED ATNH30GPLFD<br />
[UT12 NRD [UT18 NQD] [UT24 NPD] [UT30 NPD]<br />
Outdoor Units<br />
AUUH126D<br />
AUUH186D<br />
AUUH246D<br />
AUUH306D<br />
[UU12 ULD] [UU18 UED] [UU24 UED] [UU30 UED]<br />
Nominal Capacity Cooling kW<br />
3.38 5.25 7.00 8.00<br />
(Min~Rated~Max) Heating kW<br />
3.75 5.67 7.5 9.00<br />
Nominal Input Cooling kW<br />
1.29 1.85 2.49 3.62<br />
(Min~Rated~Max) Heating kW<br />
1.32 1.93 2.60 3.60<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
AVNH12GELAD UVNH186BLAD UVNH246BLAD UVNH306BLAD<br />
[UV12 NED] [UV18 NBD] [UV24 NBD] [UV30 NBD]<br />
Outdoor Units<br />
AUUH126D<br />
AUUH186D<br />
AUUH246D<br />
AUUH306D<br />
[UU12 ULD] [UU18 UED] [UU24 UED] [UU30 UED]<br />
Nominal Capacity Cooling kW<br />
3.27 4.45 6.50 7.80<br />
(Min~Rated~Max) Heating kW<br />
3.75 5.4 7.3 8.80<br />
Nominal Input Cooling kW<br />
1.3 1.84 2.49 3.53<br />
(Min~Rated~Max) Heating kW<br />
1.32 2.00 2.6 3.65<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
ABNH186HLAD<br />
ABNH246HLAD<br />
ABNH306GLAD<br />
[UB18 NHD]<br />
[UB24 NHD]<br />
[UB30 NGD]<br />
AUUH186D<br />
AUUH246D<br />
AUUH306D<br />
[UU18 UED]<br />
[UU24 UED]<br />
[UU30 UED]<br />
4.95 6.5 8.00<br />
5.8 7.40 9.00<br />
1.96 2.49 3.60<br />
2.18 2.6 3.20<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 247
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units AUUH126D[UU12 ULD] AUUH186D[UU18 UED] AUUH246D[UU24 UED] AUUH306D[UU30 UED]<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power Sup<strong>pl</strong>y Ø,V,Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable (Includes earth) No.* mm 2<br />
Compressor Type<br />
Quantity<br />
Model<br />
Motor Input kW<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge* g<br />
Type<br />
Control<br />
Heat exchnager Tube Size (OD) mm<br />
Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Fan Type<br />
No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level(H/L) Sound Press,1m dB(A)+3<br />
Defrosting<br />
SVC Valve Liquid mm<br />
Gas mm<br />
Dimensions W*H*D mm<br />
Net Weight (Outdoor) kg<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge (Over 7.5m) g/m<br />
5.8/5.95 8.26/8.6 11.4/12.6 17.2/16.3<br />
24 36 62 82<br />
1,220-240,50 1,220-240,50 1,220-240,50 1,220-240,50<br />
3*2.5 3*2.5 3*2.5 3*3.5<br />
4*0.75 4*0.75 4*0.75 4*0.75<br />
Rotary Rotary Rotary Rotary<br />
1 1 1 1<br />
GK151PAC 5KS225DAF21 GP290PAC GPT407P<br />
1.24 1.98 2.50 2.17<br />
350 600 1,130 1,200<br />
FVC68D (PVE) FV50S (PVE) FVC68D (PVE) FVC68D (PVE)<br />
1,200 1,300 1,950 1,870<br />
R410A R410A R410A R410A<br />
capillary EEV EEV EEV<br />
7.0 7.0 7.0 7.0<br />
18 18 18 18<br />
2R,24C 2R,28C 2R,36C 2R,36C<br />
OBM-2012P2 IC28640LG28P IC28640LG28P IC28640LG28J<br />
0.25 0.67 0.67 0.67<br />
1.5/370 6/370 6/370 6/370<br />
Propeller Propeller Propeller Propeller<br />
1/400 1/460 1/460 1/460<br />
Side Discharge Side Discharge Side Discharge Side Discharge<br />
26 53 53 53<br />
47 52 52 53<br />
Reversing cycle Reversing cycle Reversing cycle Reversing cycle<br />
6.35 6.35 9.52 9.52<br />
9.52 12.7 15.88 15.88<br />
770*545*245 870*655*320 870*808*320 870*808*320<br />
31 52 60 64<br />
15/10 50/30 40/30 50/30<br />
20 35 45 45<br />
Notes:<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m(25ft)<br />
- Level Difference <strong>of</strong> Zero.<br />
2. * : Full factory charge is shipped in the outdoor unit. The charge is determined based on 7.5m(25ft) <strong>of</strong> line.<br />
3. Due to our policy <strong>of</strong> innovation some specifications may be changed without notification.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
248 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Capacity and Nominal Input<br />
Indoor Units<br />
Outdoor Units<br />
Nominal Capacity Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Nominal Input Cooling kW<br />
(Min~Rated~Max) Heating kW<br />
Specifications<br />
ATNH36GNLED<br />
ATNH48GMLED<br />
ATNH60GMLED<br />
[UT36 NND]<br />
[UT48 NMD]<br />
[UT60 NMD]<br />
AUUH368D<br />
AUUH488D<br />
AUUH608D<br />
[UU37 UED]<br />
[UU48 U3D]<br />
[UU60 U3D]<br />
10.00 13.70 14.30<br />
11.00 15.00 17.00<br />
3.80 5.40 5.90<br />
3.40 5.00 5.80<br />
UVNH366KLAD<br />
UVNH486LLAD<br />
UVNH606LLAD<br />
[UV36 NKD]<br />
[UV48 NLD]<br />
[UV60 NLD]<br />
AUUH368D<br />
AUUH488D<br />
AUUH608D<br />
[UU37 UED]<br />
[UU48 U3D]<br />
[UU60 U3D]<br />
10.00 13.20 14.3<br />
11.00 16.00 17.0<br />
3.72 5.30 5.90<br />
3.78 5.10 5.80<br />
ABNH366GLAD<br />
ABNH486RLAD<br />
ABNH606RLAD<br />
[UB36 NGD]<br />
[UB48 NRD]<br />
[UB60 NRD]<br />
AUUH368D<br />
AUUH488D<br />
AUUH608D<br />
[UU37 UED]<br />
[UU48 U3D]<br />
[UU60 U3D]<br />
10.00 13.70 14.90<br />
11.00 16.00 17.50<br />
4.00 5.84 6.30<br />
3.60 5.10 5.00<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 249
Specifications 5CSL0-06B<br />
Nominal Capacity and Nominal Input<br />
Outdoor Units AUUH368D[UU37 UED] AUUH488D[UU48 U3D] AUUH608D[UU60 U3D]<br />
Running Current Cooling/Heating A<br />
Starting Current Cooling/Heating A<br />
Power Sup<strong>pl</strong>y Ø,V,Hz<br />
Power Sup<strong>pl</strong>y Cable (Includes earth) No.* mm 2<br />
Interunit Cable (Includes earth) No.* mm 2<br />
Compressor Type<br />
Quantity<br />
Model<br />
Motor Input kW<br />
Oil Charge cc<br />
Oil Type<br />
Refrigerant Charge* g<br />
Type<br />
Control<br />
Heat exchnager Tube Size (OD) mm<br />
Fins per inch<br />
No. <strong>of</strong> Rows & Column/No.<br />
Fan motor Model<br />
Output kW<br />
Capacitor μF/Vac<br />
Fan Type<br />
No. Used / Diameter EA/mm<br />
Discharge Side / Top<br />
Air Circulation CMM<br />
Noise Level(H/L) Sound Press,1m dB(A)+3<br />
Defrosting<br />
SVC Valve Liquid mm<br />
Gas mm<br />
Dimensions W*H*D mm<br />
Net Weight (Outdoor) kg<br />
Max. Piping Length/Elevation m<br />
Additional Refrigerant Charge g/m<br />
7.5/7.7 6.5/6.4 6.9/6.7<br />
47 63 67<br />
3,380-415,50 3,380-415,50 3,380-415,50<br />
5*2.5 5*2.5 5*2.5<br />
4*0.75 4*0.75 4*0.75<br />
Scroll Scroll Scroll<br />
1 1 1<br />
AQ042YAA AR061YAB ARA068YAA<br />
3.6 4.4 5.3<br />
1,200 1,800 1,800<br />
FVC68D (PVE) FVC68D (PVE) FVC68D (PVE)<br />
2,450 3,300 3,500<br />
R410A R410A R410A<br />
EEV EEV EEV<br />
7.0 7.0 7.0<br />
18 17 17<br />
2R,48C 2R 64C 2R 64C<br />
5BM-3018P2*2 YDK75-6M YDK75-6M<br />
47*2 63*2 63*2<br />
2.0/400 6/370 6/370<br />
Propeller Propeller Propeller<br />
2 /400 2/520 2/520<br />
Side Discharge Side Discharge Side Discharge<br />
32*2 55*2 55*2<br />
52 55 55<br />
Reversing cycle Reversing cycle Reversing cycle<br />
9.52 9.52 9.52<br />
15.88 15.88 15.88<br />
870*1,060*320 950*1,380*330 950*1,380*330<br />
85(187) 105(231) 105(231)<br />
50/30 50/30 50/30<br />
45 50 40<br />
Notes:<br />
1. Capacities are based on the following conditions:<br />
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />
Piping Length - Interconnecting Piping Length 7.5m(25ft)<br />
- Level Difference <strong>of</strong> Zero.<br />
2. * : Full factory charge is shipped in the outdoor unit. The charge is determined based on 7.5m(25ft) <strong>of</strong> line.<br />
3. Due to our policy <strong>of</strong> innovation some specifications may be changed without notification.<br />
4. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Conversion Formula<br />
kcal/h = kW × 859.8<br />
CFM = CMM × 35.3<br />
250 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Dimensions<br />
2.3.4 Dimensions<br />
1) Outdoor unit<br />
AUUH126D [UU12 ULD]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
6<br />
Earth screw<br />
SVC valve cover<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
AUUH126D[UU12 ULD]<br />
1/ 220-240 / 50<br />
Simultaneous operation<br />
Refer to combination table<br />
6.35<br />
9.52<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 251<br />
Note
Dimensions<br />
AUUH186D [UU18 UED]<br />
Part Name Remark<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
870<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
160<br />
546<br />
6<br />
Earth screw<br />
SVC valve cover<br />
340<br />
360<br />
10<br />
54.6<br />
AUUH186D[UU18 UED]<br />
Model name<br />
1Ø, 220-240V, 50Hz<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Simultaneous operation<br />
Refer to combination table<br />
Heating Capacity<br />
6.35<br />
12.7<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
301<br />
320<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
252 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
Ø531<br />
Note<br />
4<br />
1<br />
513<br />
630<br />
655<br />
2<br />
319<br />
3<br />
5<br />
50<br />
80<br />
25
5CSL0-06B Dimensions<br />
AUUH246D[UU24 UED]<br />
AUUH306D[UU30 UED]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
6<br />
Earth screw<br />
SVC valve cover<br />
AUUH246D[UU24 UED] AUUH306D[UU30 UED]<br />
1Ø, 220-240V, 50Hz 1Ø, 220-240V, 50Hz<br />
Simultaneous operation<br />
Refer to combination table<br />
9.52<br />
9.52<br />
15.88<br />
15.88<br />
Model name<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Heating Capacity<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 253<br />
1
Dimensions<br />
AUUH368D[UU37 UED]<br />
Part Name Remark<br />
Air discharge grille<br />
Gas pipe connection<br />
Liquid pipe connection<br />
Power & transmission connection<br />
6<br />
Earth screw<br />
SVC valve cover<br />
No.<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
AUUH368D[UU37 UED]<br />
Model name<br />
1Ø, 220-240V, 50Hz<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Simultaneous operation<br />
Refer to combination table<br />
Heating Capacity<br />
9.52<br />
15.88<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
5CSL0-06B<br />
254 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
Note
5CSL0-06B Dimensions<br />
AUUH488D[UU48 U3D]<br />
AUUH608D[UU60 U3D]<br />
4<br />
Supporter<br />
AUUH608D[UU60 U3D]<br />
3Ø, 380-415V, 50Hz<br />
AUUH488D[UU48 U3D]<br />
Model name<br />
3Ø, 380-415V, 50Hz<br />
Power Sup<strong>pl</strong>y<br />
Cooling Capacity<br />
Simultaneous operation<br />
Refer to combination table<br />
Heating Capacity<br />
9.52<br />
15.88<br />
9.52<br />
15.88<br />
Ø/V/Hz<br />
kW<br />
kW<br />
mm<br />
mm<br />
Liquid<br />
Gas<br />
Piping<br />
Connections<br />
1. Unit should be installed in com<strong>pl</strong>iance with the installation manual in<br />
the product box.<br />
2. Unit should be grounded in accordance with the local regulations or<br />
ap<strong>pl</strong>icable national codes.<br />
3. All electrical components and materials to be sup<strong>pl</strong>ied on the site<br />
must com<strong>pl</strong>y with the local regulations or international codes.<br />
4. Electrical characteristics chapter should be considered for electrical<br />
work and design. Especially the capacity <strong>of</strong> power cable and circuit<br />
breaker for outdoor unit should be more than that <strong>of</strong> electrical<br />
characteristics chapter.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 255<br />
Note<br />
490<br />
CHASSIS CODE: U3
Piping diagram<br />
2.3.5 Piping diagram<br />
Models :AUUH126D[UU12 ULD]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 9.52mm)<br />
Liquid<br />
(Ø 6.35mm)<br />
Capillary<br />
Accumulator<br />
Reversing<br />
Valve<br />
Constant<br />
Compressor<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
Th1 Thermistor for condenser pipe temperature CN_TH<br />
Th2 Thermistor for outdoor air temperature CN_TH<br />
5CSL0-06B<br />
256 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
Th2<br />
Th1
5CSL0-06B Piping diagram<br />
Models : AUUH186D[UU18 UED]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 12.7mm)<br />
Liquid<br />
(Ø 6.35mm)<br />
EEV<br />
Accumulator<br />
Reversing<br />
Valve<br />
Constant<br />
Compressor<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_LEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH2<br />
Th2 Thermistor for discharge pipe temperature CN_TH2<br />
Th3 Thermistor for condenser pipe temperature CN_TH1<br />
Th4 Thermistor for outdoor air temperature CN_TH1<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 257<br />
Th1<br />
Th2<br />
Th4<br />
Th3
Piping diagram<br />
Models : AUUH246D[UU24 UED], AUUH306D [UU30 UED]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
EEV<br />
Accumulator<br />
Reversing<br />
Valve<br />
Constant<br />
Compressor<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
5CSL0-06B<br />
258 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
Th.1<br />
Th.2<br />
High<br />
pressure<br />
S/W<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN_LEV1<br />
Th1 Thermistor for suction pipe temperature CN_TH2<br />
Th2 Thermistor for discharge pipe temperature CN_TH2<br />
Th3 Thermistor for condenser pipe temperature CN_TH1<br />
Th4 Thermistor for outdoor air temperature CN_TH1<br />
Th.4<br />
Th.3
5CSL0-06B Piping diagram<br />
Models: AUUH368D [UU37 UED]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
EEV<br />
Accumulator<br />
r<br />
Th1<br />
Reversing<br />
Valve<br />
Constant<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN-EEV1<br />
Th1 Thermistor for suction pipe temperature CN-TH2<br />
Th2 Thermistor for discharge pipe temperature CN-TH2<br />
Th3 Thermistor for condenser pipe temperature CN-TH1<br />
Th4 Thermistor for outdoor air temperature CN-TH1<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 259<br />
Th2<br />
Th3<br />
Th4
Piping diagram<br />
Models: AUUH488D [UU48 U3D], AUUH608D [UU60 U3D]<br />
Field Piping<br />
Refrigerant Flow<br />
Cooling<br />
Heating<br />
Gas<br />
(Ø 15.88mm)<br />
Liquid<br />
(Ø 9.52mm)<br />
EEV<br />
Low Pressure<br />
S/W<br />
Accumulator<br />
r<br />
Th1<br />
Reversing<br />
Valve<br />
Constant<br />
Compressor<br />
High Pressure<br />
S/W<br />
OUTDOOR UNIT<br />
Heat<br />
Exchanger<br />
LOC. Description PCB Connector<br />
EEV Electronic Expansion Valve CN-EEV1<br />
Th1 Thermistor for suction pipe temperature CN-TH2<br />
Th2 Thermistor for discharge pipe temperature CN-TH2<br />
Th3 Thermistor for condenser pipe temperature CN-TH1<br />
Th4 Thermistor for outdoor air temperature CN-TH1<br />
5CSL0-06B<br />
260 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
Th2<br />
Th3<br />
Th4
5CSL0-06B Wiring diagrams<br />
2.3.6 Wiring diagrams<br />
Models : AUUH126D [UU12 ULD]<br />
Communication<br />
CENTRAL CONTROLLER<br />
POWER SUPPLY<br />
CN_POWER<br />
4WAY VALVE<br />
(Main power) COMP FAN<br />
LEV 1<br />
EEPROM<br />
CENTRAL<br />
CONTROLLER<br />
SENSOR<br />
(Air, Cond)<br />
SENSOR<br />
(Dis, Suc)<br />
LGMV<br />
FLASH<br />
(ON bording)<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 261
Wiring diagrams<br />
Model: AUUH186D[UU18 UED]<br />
Central controller<br />
POWER SUPPLY<br />
CN_COM<br />
(Communication)<br />
CN_POWER<br />
(Main power)<br />
COMP 1<br />
CN_FAN 1<br />
SMPS CN_TH 2 CN_CENTRAL<br />
(Suction discharge)<br />
CN_TH 1<br />
(Pipe out)<br />
CN_SV<br />
(4WAY VALVE)<br />
5CSL0-06B<br />
CN_TEST<br />
CN_LEV 1<br />
262 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Wiring diagrams<br />
Models : AUUH246D[UU24 UED]<br />
Central controller<br />
POWER SUPPLY<br />
CN_COM<br />
(Communication)<br />
CN_POWER<br />
(Main power)<br />
COMP 1<br />
CN_FAN 1<br />
SMPS CN_TH 2 CN_CENTRAL<br />
(Suction discharge)<br />
CN_TH 1<br />
(Pipe out)<br />
CN_SV<br />
(4WAY VALVE)<br />
CN_TEST<br />
CN_LEV 1<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 263
Wiring diagrams<br />
Models : AUUH306D [UU30 UED]<br />
CN-PRESS<br />
CN-COM<br />
CENTRAL CONTROLLER<br />
POWER SUPPLY<br />
CN-POWER<br />
(Main Power) RY_COMP2 CN_4WAY<br />
CN_LEV1 EEP ROM<br />
CN_FAN<br />
5CSL0-06B<br />
CENTRAL<br />
CONTROLLER<br />
CN_TH1<br />
CN_TH2<br />
CN_LGMV<br />
CN_FLASH<br />
(ON boarding)<br />
264 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Wiring diagrams<br />
Models : AUUH368D[UU37 UED]<br />
Error Indicator<br />
EEPROM<br />
Central<br />
Controller<br />
Power sup<strong>pl</strong>y<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 265
Wiring diagrams<br />
Models : AUUH488D[UU48 U3D], AUUH608D[UU60 U3D]<br />
CENTRAL<br />
CONTROLLER<br />
POWER<br />
SUPPLY<br />
CN_COM<br />
CN_POWER CN_PRESS1 CN_COMP CN_4WAY<br />
CN_3PHASE<br />
EEPROM<br />
CN_LEV1<br />
CN_<br />
PHASE_FAN<br />
CN_LGMV<br />
5CSL0-06B<br />
Error Indicator<br />
CN_<br />
CENTRAL<br />
CN_<br />
FLASH<br />
CN_TH1<br />
(AIR/PIPE1)<br />
CN_TH2<br />
(PIPE2/DIS1)<br />
266 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
2.3.7 Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH126D + ATNH12GRLED, AVNH12GELAD<br />
[UU12 ULD] + [UT12 NRD], [UV12 NED]<br />
Model ATNH12GRLED[UT12 NRD]<br />
AFR 9.5<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 2.74 2.36 0.85 2.68 2.34 1.00 2.56 2.28 1.17 2.48 2.23 1.23 2.39 2.18 1.31 2.33 2.15 1.35<br />
16.0 22.0 3.20 2.68 0.86 3.13 2.65 1.02 2.98 2.58 1.19 2.89 2.52 1.25 2.79 2.46 1.33 2.72 2.42 1.37<br />
18.0 25.0 3.57 2.92 0.87 3.49 2.88 1.03 3.33 2.79 1.20 3.23 2.73 1.27 3.11 2.66 1.35 3.04 2.62 1.39<br />
19.0 27.0 3.74 3.01 0.89 3.66 2.98 1.05 3.48 2.88 1.22 3.38 2.82 1.29 3.25 2.75 1.37 3.18 2.70 1.42<br />
22.0 30.0 4.10 3.20 0.90 4.01 3.16 1.06 3.82 3.05 1.24 3.71 2.98 1.31 3.57 2.89 1.39 3.49 2.84 1.44<br />
24.0 32.0 4.25 3.25 0.91 4.16 3.20 1.08 3.97 3.09 1.26 3.85 3.02 1.33 3.71 2.93 1.41 3.62 2.88 1.46<br />
Model AVNH12GELAD[UV12 NED]<br />
AFR 9.2<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 2.65 2.29 0.85 2.60 2.27 1.01 2.47 2.20 1.18 2.40 2.16 1.24 2.31 2.11 1.32 2.26 2.08 1.36<br />
16.0 22.0 3.09 2.60 0.86 3.03 2.57 1.03 2.89 2.50 1.20 2.80 2.44 1.26 2.70 2.38 1.34 2.63 2.35 1.38<br />
18.0 25.0 3.45 2.82 0.88 3.38 2.79 1.04 3.22 2.71 1.21 3.12 2.65 1.28 3.01 2.58 1.36 2.94 2.54 1.40<br />
19.0 27.0 3.61 2.92 0.89 3.54 2.89 1.06 3.37 2.79 1.23 3.27 2.73 1.30 3.15 2.66 1.38 3.08 2.62 1.43<br />
22.0 30.0 3.97 3.10 0.90 3.88 3.06 1.07 3.70 2.95 1.25 3.59 2.88 1.32 3.45 2.80 1.40 3.38 2.75 1.45<br />
24.0 32.0 4.12 3.15 0.92 4.03 3.10 1.09 3.84 3.00 1.27 3.72 2.92 1.34 3.59 2.84 1.42 3.50 2.79 1.47<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 267
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH126D + ATNH12GRLED, AVNH12GELAD<br />
[UU12 ULD] + [UT12 NRD], [UV12 NED]<br />
Model ATNH12GRLED[UT12 NRD]<br />
AFR 9.5<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 2.53 0.96 2.98 1.05 3.45 1.15 3.63 1.18 3.80 1.22 4.01 1.24 4.35 1.30 4.80 1.39<br />
18.0 2.45 1.00 2.89 1.09 3.34 1.18 3.51 1.22 3.68 1.26 3.89 1.28 4.21 1.35 4.64 1.44<br />
20.0 2.38 1.03 2.80 1.12 3.24 1.22 3.41 1.26 3.57 1.30 3.75 1.32 4.08 1.39 4.51 1.49<br />
22.0 2.29 1.06 2.70 1.16 3.13 1.26 3.28 1.30 3.44 1.34 3.64 1.36 3.94 1.44 4.34 1.54<br />
24.0 2.21 1.09 2.61 1.19 3.02 1.30 3.17 1.34 3.32 1.38 3.51 1.41 3.80 1.48 4.19 1.58<br />
Model AVNH12GELAD[UV12 NED]<br />
AFR 9.2<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 2.53 0.96 2.98 1.05 3.45 1.15 3.63 1.18 3.80 1.22 4.01 1.24 4.35 1.30 4.80 1.39<br />
18.0 2.45 1.00 2.89 1.09 3.34 1.18 3.51 1.22 3.68 1.26 3.89 1.28 4.21 1.35 4.64 1.44<br />
20.0 2.38 1.03 2.80 1.12 3.24 1.22 3.41 1.26 3.57 1.30 3.75 1.32 4.08 1.39 4.51 1.49<br />
22.0 2.29 1.06 2.70 1.16 3.13 1.26 3.28 1.30 3.44 1.34 3.64 1.36 3.94 1.44 4.34 1.54<br />
24.0 2.21 1.09 2.61 1.19 3.02 1.30 3.17 1.34 3.32 1.38 3.51 1.41 3.80 1.48 4.19 1.58<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
268 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH186D + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD<br />
[UU18 UED] + [UT18 NQD], [UV18 NBD], [UB18 NHD]<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 4.26 3.08 1.21 4.17 3.05 1.44 3.97 2.97 1.68 3.85 2.91 1.76 3.71 2.85 1.88 3.62 2.81 1.94<br />
16.0 22.0 4.97 3.50 1.23 4.86 3.46 1.46 4.63 3.36 1.70 4.50 3.29 1.79 4.33 3.21 1.91 4.23 3.16 1.97<br />
18.0 25.0 5.54 3.81 1.25 5.43 3.76 1.48 5.17 3.65 1.73 5.02 3.57 1.82 4.83 3.48 1.93 4.72 3.42 2.00<br />
19.0 27.0 5.80 3.93 1.27 5.68 3.89 1.51 5.41 3.77 1.76 5.25 3.68 1.85 5.05 3.59 1.97 4.94 3.53 2.03<br />
22.0 30.0 6.37 4.17 1.29 6.23 4.12 1.53 5.94 3.98 1.78 5.76 3.89 1.87 5.55 3.78 1.99 5.42 3.71 2.06<br />
24.0 32.0 6.61 4.24 1.31 6.47 4.18 1.55 6.16 4.04 1.80 5.98 3.94 1.90 5.76 3.83 2.02 5.62 3.76 2.09<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 3.61 2.84 1.21 3.53 2.81 1.43 3.37 2.74 1.67 3.27 2.68 1.76 3.14 2.62 1.87 3.07 2.58 1.93<br />
16.0 22.0 4.21 3.22 1.22 4.12 3.19 1.45 3.93 3.10 1.69 3.81 3.03 1.78 3.67 2.96 1.90 3.58 2.92 1.96<br />
18.0 25.0 4.70 3.51 1.24 4.60 3.47 1.47 4.38 3.36 1.72 4.25 3.29 1.81 4.09 3.20 1.92 4.00 3.15 1.99<br />
19.0 27.0 4.92 3.63 1.26 4.81 3.58 1.50 4.59 3.47 1.75 4.45 3.39 1.84 4.28 3.30 1.96 4.19 3.25 2.02<br />
22.0 30.0 5.40 3.85 1.28 5.28 3.80 1.52 5.03 3.67 1.77 4.88 3.58 1.86 4.70 3.48 1.98 4.59 3.42 2.05<br />
24.0 32.0 5.60 3.91 1.30 5.48 3.86 1.54 5.22 3.72 1.79 5.07 3.63 1.89 4.88 3.53 2.01 4.77 3.46 2.08<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 4.01 3.69 1.28 3.93 3.65 1.52 3.74 3.55 1.77 3.63 3.48 1.87 3.50 3.40 1.99 3.42 3.35 2.05<br />
16.0 22.0 4.68 4.18 1.30 4.59 4.14 1.55 4.37 4.02 1.80 4.24 3.93 1.90 4.08 3.84 2.02 3.99 3.78 2.09<br />
18.0 25.0 5.23 4.55 1.32 5.12 4.50 1.57 4.88 4.36 1.83 4.73 4.26 1.93 4.55 4.16 2.05 4.45 4.09 2.12<br />
19.0 27.0 5.47 4.71 1.35 5.35 4.65 1.60 5.10 4.50 1.86 4.95 4.40 1.96 4.77 4.29 2.08 4.66 4.22 2.15<br />
22.0 30.0 6.00 4.99 1.36 5.88 4.93 1.62 5.60 4.76 1.88 5.43 4.65 1.99 5.23 4.52 2.11 5.11 4.44 2.18<br />
24.0 32.0 6.23 5.07 1.38 6.10 5.00 1.64 5.81 4.83 1.91 5.64 4.71 2.01 5.43 4.58 2.14 5.30 4.49 2.21<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 269
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH186D + ATNH18GQLED, UVNH186BLAD, ABNH186HLAD<br />
[UU18 UED] + [UT18 NQD], [UV18 NBD], [UB18 NHD]<br />
Model ATNH18GQLED[UT18 NQD]<br />
AFR 13<br />
Model UVNH186BLAD[UV18 NBD]<br />
AFR 13.5<br />
Model ABNH186HLAD[UB18 NHD]<br />
AFR 16.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 3.83 1.41 4.51 1.54 5.22 1.68 5.48 1.73 5.74 1.78 6.07 1.81 6.57 1.90 7.25 2.04<br />
18.0 3.71 1.46 4.37 1.59 5.05 1.73 5.31 1.79 5.56 1.84 5.88 1.87 6.36 1.97 7.02 2.11<br />
20.0 3.60 1.50 4.24 1.64 4.90 1.79 5.15 1.84 5.40 1.90 5.67 1.93 6.17 2.03 6.81 2.18<br />
22.0 3.47 1.55 4.08 1.69 4.73 1.85 4.96 1.90 5.20 1.96 5.50 1.99 5.95 2.10 6.57 2.25<br />
24.0 3.35 1.60 3.94 1.75 4.56 1.90 4.79 1.96 5.02 2.02 5.31 2.05 5.74 2.16 6.34 2.32<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 3.65 1.46 4.30 1.59 4.97 1.74 5.22 1.79 5.47 1.84 5.78 1.87 6.26 1.97 6.91 2.11<br />
18.0 3.53 1.51 4.16 1.65 4.81 1.79 5.05 1.85 5.30 1.91 5.60 1.94 6.06 2.04 6.69 2.19<br />
20.0 3.43 1.56 4.04 1.70 4.67 1.85 4.90 1.91 5.14 1.97 5.40 2.00 5.88 2.11 6.49 2.26<br />
22.0 3.30 1.61 3.89 1.76 4.50 1.91 4.73 1.97 4.95 2.03 5.23 2.07 5.67 2.17 6.25 2.33<br />
24.0 3.19 1.66 3.76 1.81 4.35 1.97 4.57 2.03 4.78 2.09 5.05 2.13 5.47 2.24 6.04 2.40<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 3.92 1.59 4.61 1.74 5.34 1.89 5.61 1.95 5.87 2.01 6.21 2.04 6.72 2.15 7.42 2.30<br />
18.0 3.79 1.64 4.47 1.80 5.17 1.96 5.43 2.02 5.69 2.08 6.01 2.11 6.51 2.22 7.18 2.38<br />
20.0 3.68 1.70 4.33 1.85 5.01 2.02 5.27 2.08 5.52 2.14 5.80 2.18 6.31 2.30 6.97 2.46<br />
22.0 3.55 1.75 4.18 1.91 4.83 2.08 5.08 2.15 5.32 2.21 5.62 2.25 6.08 2.37 6.72 2.54<br />
24.0 3.42 1.81 4.03 1.97 4.67 2.15 4.90 2.21 5.14 2.28 5.43 2.32 5.88 2.44 6.48 2.62<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
270 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH246D + ATNH24GPLED , UVNH246BLAD, ABNH246HLAD<br />
[UU24 UED]+ [UT24 NPD], [UV24 NBD], [UB24 NHD]<br />
Model ATNH24GPLED[UT24 NPD]<br />
AFR 17<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.68 4.63 1.63 5.56 4.59 1.93 5.30 4.46 2.25 5.14 4.37 2.38 4.95 4.28 2.53 4.83 4.22 2.61<br />
16.0 22.0 6.62 5.26 1.66 6.48 5.21 1.96 6.18 5.05 2.29 5.99 4.94 2.41 5.77 4.83 2.57 5.64 4.76 2.65<br />
18.0 25.0 7.39 5.72 1.68 7.23 5.66 1.99 6.89 5.48 2.32 6.69 5.36 2.45 6.44 5.22 2.60 6.29 5.14 2.69<br />
19.0 27.0 7.74 5.91 1.71 7.57 5.84 2.03 7.22 5.66 2.36 7.00 5.53 2.49 6.74 5.39 2.65 6.58 5.30 2.74<br />
22.0 30.0 8.49 6.27 1.73 8.31 6.19 2.05 7.92 5.98 2.39 7.68 5.84 2.52 7.40 5.68 2.68 7.22 5.58 2.77<br />
24.0 32.0 8.81 6.38 1.76 8.62 6.29 2.08 8.22 6.07 2.43 7.97 5.92 2.56 7.68 5.75 2.72 7.50 5.64 2.81<br />
Model UVNH246BLAD[UV24 NBD]<br />
AFR 15<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.27 4.03 1.63 5.16 3.99 1.93 4.92 3.88 2.25 4.77 3.80 2.38 4.59 3.72 2.53 4.49 3.67 2.61<br />
16.0 22.0 6.15 4.57 1.66 6.02 4.53 1.96 5.74 4.40 2.29 5.57 4.30 2.41 5.36 4.20 2.57 5.23 4.14 2.65<br />
18.0 25.0 6.86 4.97 1.68 6.72 4.92 1.99 6.40 4.77 2.32 6.21 4.66 2.45 5.98 4.54 2.60 5.84 4.47 2.69<br />
19.0 27.0 7.18 5.14 1.71 7.03 5.08 2.03 6.70 4.92 2.36 6.50 4.81 2.49 6.26 4.69 2.65 6.11 4.61 2.74<br />
22.0 30.0 7.88 5.45 1.73 7.72 5.38 2.05 7.35 5.20 2.39 7.13 5.08 2.52 6.87 4.94 2.68 6.71 4.85 2.77<br />
24.0 32.0 8.18 5.55 1.76 8.01 5.47 2.08 7.63 5.28 2.43 7.40 5.15 2.56 7.13 5.00 2.72 6.96 4.91 2.81<br />
Model ABNH246HLAD[UB24 NHD]<br />
AFR 18<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 5.27 3.87 1.63 5.16 3.84 1.93 4.92 3.73 2.25 4.77 3.65 2.38 4.59 3.57 2.53 4.49 3.52 2.61<br />
16.0 22.0 6.15 4.39 1.66 6.02 4.35 1.96 5.74 4.22 2.29 5.57 4.13 2.41 5.36 4.04 2.57 5.23 3.97 2.65<br />
18.0 25.0 6.86 4.78 1.68 6.72 4.73 1.99 6.40 4.58 2.32 6.21 4.48 2.45 5.98 4.37 2.60 5.84 4.30 2.69<br />
19.0 27.0 7.18 4.94 1.71 7.03 4.88 2.03 6.70 4.73 2.36 6.50 4.62 2.49 6.26 4.50 2.65 6.11 4.43 2.74<br />
22.0 30.0 7.88 5.24 1.73 7.72 5.17 2.05 7.35 5.00 2.39 7.13 4.88 2.52 6.87 4.75 2.68 6.71 4.66 2.77<br />
24.0 32.0 8.18 5.33 1.76 8.01 5.25 2.08 7.63 5.07 2.43 7.40 4.95 2.56 7.13 4.81 2.72 6.96 4.72 2.81<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 271
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH246D + ATNH24GPLED , UVNH246BLAD, ABNH246HLAD<br />
[UU24 UED]+ [UT24 NPD], [UV24 NBD], [UB24 NHD]<br />
Model ATNH24GPLED[UT24 NPD]<br />
AFR 17<br />
Model UVNH246BLAD[UV24 NBD]<br />
AFR 15<br />
Model ABNH246HLAD[UB24 NHD]<br />
AFR 18<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 5.07 1.90 5.97 2.07 6.90 2.26 7.25 2.33 7.60 2.40 8.03 2.44 8.69 2.57 9.59 2.75<br />
18.0 4.91 1.96 5.78 2.14 6.69 2.33 7.02 2.40 7.36 2.48 7.77 2.52 8.42 2.65 9.29 2.84<br />
20.0 4.76 2.02 5.61 2.21 6.49 2.41 6.81 2.48 7.14 2.56 7.50 2.60 8.16 2.74 9.01 2.93<br />
22.0 4.59 2.09 5.40 2.28 6.25 2.49 6.57 2.56 6.88 2.64 7.27 2.68 7.87 2.83 8.69 3.03<br />
24.0 4.43 2.15 5.22 2.35 6.04 2.56 6.34 2.64 6.64 2.72 7.02 2.77 7.60 2.91 8.39 3.12<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 4.93 1.90 5.81 2.07 6.72 2.26 7.06 2.33 7.39 2.40 7.81 2.44 8.46 2.57 9.33 2.75<br />
18.0 4.77 1.96 5.62 2.14 6.51 2.33 6.83 2.40 7.16 2.48 7.56 2.52 8.19 2.65 9.04 2.84<br />
20.0 4.63 2.02 5.46 2.21 6.31 2.41 6.63 2.48 6.95 2.56 7.30 2.60 7.94 2.74 8.77 2.93<br />
22.0 4.46 2.09 5.26 2.28 6.08 2.49 6.39 2.56 6.70 2.64 7.07 2.68 7.66 2.83 8.45 3.03<br />
24.0 4.31 2.15 5.08 2.35 5.87 2.56 6.17 2.64 6.47 2.72 6.83 2.77 7.40 2.91 8.16 3.12<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 5.00 1.90 5.89 2.07 6.81 2.26 7.15 2.33 7.49 2.40 7.92 2.44 8.57 2.57 9.46 2.75<br />
18.0 4.84 1.96 5.70 2.14 6.59 2.33 6.93 2.40 7.26 2.48 7.67 2.52 8.30 2.65 9.16 2.84<br />
20.0 4.69 2.02 5.53 2.21 6.40 2.41 6.72 2.48 7.04 2.56 7.40 2.60 8.05 2.74 8.89 2.93<br />
22.0 4.52 2.09 5.33 2.28 6.17 2.49 6.48 2.56 6.79 2.64 7.17 2.68 7.76 2.83 8.57 3.03<br />
24.0 4.37 2.15 5.15 2.35 5.96 2.56 6.25 2.64 6.55 2.72 6.93 2.77 7.50 2.91 8.27 3.12<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
272 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH306D + ATNH30GPLED , UVNH306BLAD, ABNH306GLAD<br />
[UU30 UED]+ [UT30 NPD], [UV30 NBD], [UB30 NGD]<br />
Model ATNH30GPLED[UT30 NPD]<br />
AFR 19<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 6.49 5.29 2.37 6.35 5.25 2.81 6.05 5.10 3.28 5.87 5.00 3.45 5.65 4.89 3.67 5.52 4.82 3.79<br />
16.0 22.0 7.57 6.01 2.41 7.41 5.95 2.85 7.06 5.78 3.33 6.85 5.65 3.51 6.60 5.52 3.73 6.44 5.43 3.85<br />
18.0 25.0 8.45 6.54 2.45 8.27 6.46 2.90 7.88 6.26 3.38 7.64 6.12 3.56 7.36 5.97 3.79 7.19 5.87 3.91<br />
19.0 27.0 8.84 6.76 2.49 8.65 6.68 2.95 8.25 6.47 3.44 8.00 6.32 3.62 7.70 6.16 3.85 7.52 6.06 3.98<br />
22.0 30.0 9.70 7.17 2.52 9.50 7.07 2.98 9.05 6.84 3.48 8.78 6.67 3.67 8.45 6.49 3.90 8.26 6.38 4.03<br />
24.0 32.0 10.07 7.29 2.56 9.86 7.19 3.03 9.39 6.93 3.53 9.11 6.77 3.72 8.77 6.57 3.96 8.57 6.45 4.09<br />
Model UVNH306BLAD[UV30 NBD]<br />
AFR 18<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 6.33 4.83 2.31 6.19 4.79 2.74 5.90 4.66 3.20 5.72 4.56 3.37 5.51 4.46 3.58 5.38 4.40 3.70<br />
16.0 22.0 7.38 5.49 2.35 7.23 5.43 2.78 6.89 5.28 3.25 6.68 5.16 3.42 6.43 5.04 3.64 6.28 4.96 3.76<br />
18.0 25.0 8.24 5.97 2.38 8.06 5.90 2.83 7.68 5.72 3.30 7.45 5.59 3.47 7.18 5.45 3.69 7.01 5.37 3.81<br />
19.0 27.0 8.62 6.17 2.42 8.44 6.10 2.87 8.04 5.91 3.35 7.80 5.77 3.53 7.51 5.62 3.75 7.34 5.53 3.88<br />
22.0 30.0 9.46 6.55 2.46 9.26 6.46 2.91 8.82 6.24 3.39 8.56 6.09 3.58 8.24 5.93 3.80 8.05 5.82 3.93<br />
24.0 32.0 9.82 6.65 2.49 9.61 6.56 2.95 9.16 6.33 3.44 8.88 6.18 3.63 8.55 6.00 3.86 8.36 5.89 3.99<br />
Model ABNH306GLAD[UB30 NGD]<br />
AFR 26.5<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 6.49 5.36 2.36 6.35 5.31 2.80 6.05 5.17 3.26 5.87 5.06 3.43 5.65 4.95 3.65 5.52 4.88 3.77<br />
16.0 22.0 7.57 6.09 2.40 7.41 6.02 2.84 7.06 5.85 3.31 6.85 5.72 3.49 6.60 5.59 3.71 6.44 5.50 3.83<br />
18.0 25.0 8.45 6.62 2.43 8.27 6.55 2.88 7.88 6.34 3.36 7.64 6.20 3.54 7.36 6.05 3.77 7.19 5.95 3.89<br />
19.0 27.0 8.84 6.84 2.47 8.65 6.76 2.93 8.25 6.55 3.42 8.00 6.40 3.60 7.70 6.24 3.83 7.52 6.13 3.96<br />
22.0 30.0 9.70 7.26 2.50 9.50 7.16 2.97 9.05 6.92 3.46 8.78 6.76 3.65 8.45 6.57 3.88 8.26 6.46 4.01<br />
24.0 32.0 10.07 7.38 2.54 9.86 7.28 3.01 9.39 7.02 3.51 9.11 6.85 3.70 8.77 6.66 3.93 8.57 6.53 4.06<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 273
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH306D + ATNH30GPLED , UVNH306BLAD, ABNH306GLAD<br />
[UU30 UED]+ [UT30 NPD], [UV30 NBD], [UB30 NGD]<br />
Model ATNH30GPLED[UT30 NPD]<br />
AFR 19<br />
Model UVNH306BLAD[UV30 NBD]<br />
AFR 18<br />
Model ABNH306GLAD[UB30 NGD]<br />
AFR 26.5<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 6.08 2.62 7.16 2.87 8.28 3.12 8.70 3.22 9.11 3.32 9.63 3.37 10.4 3.55 11.5 3.80<br />
18.0 5.88 2.71 6.93 2.97 8.02 3.23 8.42 3.33 8.83 3.43 9.33 3.49 10.1 3.67 11.1 3.93<br />
20.0 5.71 2.80 6.73 3.06 7.78 3.34 8.17 3.44 8.56 3.54 9.00 3.60 9.79 3.79 10.81 4.06<br />
22.0 5.50 2.89 6.48 3.16 7.50 3.44 7.88 3.55 8.25 3.65 8.72 3.72 9.44 3.91 10.42 4.19<br />
24.0 5.31 2.98 6.26 3.26 7.24 3.55 7.61 3.66 7.97 3.77 8.42 3.83 9.12 4.03 10.06 4.32<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 5.94 2.45 7.00 2.68 8.10 2.92 8.51 3.01 8.91 3.10 9.42 3.15 10.2 3.32 11.3 3.55<br />
18.0 5.75 2.53 6.78 2.77 7.84 3.02 8.24 3.11 8.63 3.20 9.12 3.26 9.87 3.43 10.9 3.67<br />
20.0 5.58 2.62 6.58 2.86 7.61 3.11 7.99 3.21 8.37 3.31 8.80 3.36 9.58 3.54 10.6 3.79<br />
22.0 5.38 2.70 6.34 2.95 7.33 3.21 7.70 3.31 8.07 3.41 8.53 3.47 9.23 3.65 10.2 3.91<br />
24.0 5.20 2.78 6.12 3.04 7.08 3.31 7.44 3.41 7.79 3.52 8.24 3.58 8.92 3.77 9.84 4.03<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 6.08 2.33 7.16 2.55 8.28 2.78 8.70 2.86 9.11 2.95 9.63 3.00 10.4 3.16 11.5 3.38<br />
18.0 5.88 2.41 6.93 2.64 8.02 2.87 8.42 2.96 8.83 3.05 9.33 3.10 10.1 3.26 11.1 3.50<br />
20.0 5.71 2.49 6.73 2.72 7.78 2.97 8.17 3.06 8.56 3.15 9.00 3.20 9.79 3.37 10.8 3.61<br />
22.0 5.50 2.57 6.48 2.81 7.50 3.06 7.88 3.15 8.25 3.25 8.72 3.30 9.44 3.48 10.4 3.73<br />
24.0 5.31 2.65 6.26 2.90 7.24 3.15 7.61 3.25 7.97 3.35 8.42 3.41 9.12 3.59 10.1 3.84<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
274 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH368D + ATNH36GNLED , UVNH366KLAD, ABNH366GLAD<br />
[UU37 UED]+ [UT36 NND] , [UV36 NKD] , [UB36 NGD]<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.11 6.64 2.49 7.94 6.58 2.95 7.56 6.40 3.44 7.34 6.27 3.62 7.07 6.13 3.86 6.90 6.04 3.98<br />
16.0 22.0 9.46 7.54 2.53 9.26 7.47 3.00 8.83 7.25 3.49 8.56 7.09 3.68 8.24 6.92 3.91 8.05 6.82 4.04<br />
18.0 25.0 10.6 8.20 2.57 10.3 8.11 3.04 9.85 7.86 3.55 9.55 7.68 3.74 9.20 7.49 3.97 8.99 7.37 4.11<br />
19.0 27.0 11.1 8.48 2.61 10.8 8.38 3.09 10.3 8.12 3.61 10.0 7.93 3.80 9.63 7.73 4.04 9.41 7.60 4.18<br />
22.0 30.0 12.1 8.99 2.64 11.9 8.88 3.13 11.3 8.58 3.65 11.0 8.37 3.85 10.6 8.14 4.09 10.3 8.00 4.23<br />
24.0 32.0 12.6 9.14 2.68 12.3 9.02 3.18 11.7 8.70 3.71 11.4 8.49 3.90 11.0 8.25 4.15 10.7 8.10 4.29<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.11 6.11 2.44 7.94 6.06 2.89 7.56 5.89 3.37 7.34 5.77 3.55 7.07 5.64 3.77 6.90 5.56 3.90<br />
16.0 22.0 9.46 6.94 2.48 9.26 6.87 2.93 8.83 6.67 3.42 8.56 6.53 3.60 8.24 6.37 3.83 8.05 6.28 3.96<br />
18.0 25.0 10.6 7.55 2.51 10.3 7.47 2.98 9.85 7.24 3.47 9.55 7.07 3.66 9.20 6.90 3.89 8.99 6.79 4.02<br />
19.0 27.0 11.1 7.81 2.56 10.8 7.71 3.03 10.3 7.47 3.53 10.0 7.30 3.72 9.63 7.11 3.96 9.41 7.00 4.09<br />
22.0 30.0 12.1 8.28 2.59 11.9 8.17 3.07 11.3 7.90 3.58 11.0 7.71 3.77 10.6 7.50 4.01 10.3 7.36 4.14<br />
24.0 32.0 12.6 8.42 2.63 12.3 8.30 3.11 11.7 8.01 3.63 11.4 7.81 3.82 11.0 7.59 4.07 10.7 7.45 4.20<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 8.11 6.53 2.62 7.94 6.47 3.11 7.56 6.30 3.62 7.34 6.17 3.82 7.07 6.03 4.06 6.90 5.95 4.19<br />
16.0 22.0 9.46 7.42 2.66 9.26 7.34 3.15 8.83 7.13 3.68 8.56 6.97 3.87 8.24 6.81 4.12 8.05 6.71 4.26<br />
18.0 25.0 10.6 8.07 2.70 10.3 7.98 3.20 9.85 7.73 3.73 9.55 7.56 3.93 9.20 7.37 4.18 8.99 7.25 4.32<br />
19.0 27.0 11.1 8.34 2.75 10.8 8.24 3.26 10.3 7.98 3.80 10.0 7.80 4.00 9.63 7.60 4.25 9.41 7.48 4.40<br />
22.0 30.0 12.1 8.85 2.78 11.9 8.73 3.30 11.3 8.44 3.85 11.0 8.24 4.05 10.6 8.01 4.31 10.3 7.87 4.45<br />
24.0 32.0 12.6 8.99 2.82 12.3 8.87 3.35 11.7 8.56 3.90 11.4 8.35 4.11 11.0 8.11 4.37 10.7 7.96 4.52<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 275
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH368D + ATNH36GNLED , UVNH366KLAD, ABNH366GLAD<br />
[UU37 UED]+ [UT36 NND] , [UV36 NKD] , [UB36 NGD]<br />
Model ATNH36GNLED[UT36 NND]<br />
AFR 24<br />
Model UVNH366KLAD[UV36 NKD]<br />
AFR 29<br />
Model ABNH366GLAD[UB36 NGD]<br />
AFR 32<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 7.42 2.48 8.74 2.71 10.1 2.95 10.6 3.04 11.1 3.13 11.8 3.19 12.7 3.35 14.1 3.59<br />
18.0 7.19 2.56 8.46 2.80 9.79 3.05 10.3 3.14 10.8 3.24 11.4 3.29 12.3 3.47 13.6 3.71<br />
20.0 6.97 2.65 8.21 2.89 9.50 3.15 10.0 3.25 10.5 3.35 11.0 3.40 12.0 3.58 13.2 3.84<br />
22.0 6.72 2.73 7.92 2.98 9.16 3.25 9.62 3.35 10.1 3.45 10.7 3.51 11.5 3.70 12.7 3.96<br />
24.0 6.49 2.82 7.64 3.08 8.84 3.35 9.29 3.45 9.73 3.56 10.3 3.62 11.1 3.81 12.3 4.08<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 7.42 2.76 8.74 3.01 10.1 3.28 10.6 3.38 11.1 3.48 11.8 3.54 12.7 3.73 14.1 3.99<br />
18.0 7.19 2.85 8.46 3.11 9.79 3.39 10.3 3.50 10.8 3.60 11.4 3.66 12.3 3.86 13.6 4.13<br />
20.0 6.97 2.94 8.21 3.22 9.50 3.50 10.0 3.61 10.5 3.72 11.0 3.78 12.0 3.98 13.2 4.27<br />
22.0 6.72 3.04 7.92 3.32 9.16 3.61 9.62 3.73 10.1 3.84 10.7 3.90 11.5 4.11 12.7 4.40<br />
24.0 6.49 3.13 7.64 3.42 8.84 3.73 9.29 3.84 9.73 3.96 10.3 4.02 11.1 4.24 12.3 4.54<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 7.42 2.62 8.74 2.87 10.1 3.12 10.6 3.22 11.1 3.32 11.8 3.37 12.7 3.55 14.1 3.80<br />
18.0 7.19 2.71 8.46 2.97 9.79 3.23 10.3 3.33 10.8 3.43 11.4 3.49 12.3 3.67 13.6 3.93<br />
20.0 6.97 2.80 8.21 3.06 9.50 3.34 10.0 3.44 10.5 3.54 11.0 3.60 12.0 3.79 13.2 4.06<br />
22.0 6.72 2.89 7.92 3.16 9.16 3.44 9.6 3.55 10.1 3.65 10.7 3.72 11.5 3.91 12.7 4.19<br />
24.0 6.49 2.98 7.64 3.26 8.84 3.55 9.3 3.66 9.7 3.77 10.3 3.83 11.1 4.03 12.3 4.32<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
276 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH488D + ATNH48GMLED , UVNH486LLAD , ABNH486RLAD<br />
[UU48 U3D]+ [UT48 NMD] , [UV48 NLD] , [UB48 NRD]<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 11.1 8.8 3.54 10.9 8.72 4.19 10.4 8.48 4.89 10.1 8.31 5.15 9.68 8.12 5.48 9.46 8.01 5.66<br />
16.0 22.0 13.0 10.0 3.59 12.7 9.89 4.26 12.1 9.60 4.97 11.7 9.40 5.23 11.3 9.17 5.56 11.0 9.04 5.75<br />
18.0 25.0 14.5 10.9 3.65 14.2 10.7 4.32 13.5 10.4 5.04 13.1 10.2 5.31 12.6 9.93 5.65 12.3 9.77 5.83<br />
19.0 27.0 15.1 11.2 3.71 14.8 11.1 4.40 14.1 10.8 5.13 13.7 10.5 5.40 13.2 10.2 5.74 12.9 10.1 5.93<br />
22.0 30.0 16.6 11.9 3.76 16.3 11.8 4.45 15.5 11.4 5.19 15.0 11.1 5.47 14.5 10.8 5.82 14.1 10.6 6.01<br />
24.0 32.0 17.2 12.1 3.81 16.9 11.9 4.52 16.1 11.5 5.27 15.6 11.2 5.55 15.0 10.9 5.90 14.7 10.7 6.10<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 10.7 8.29 3.47 10.5 8.22 4.12 10.0 7.99 4.80 9.69 7.83 5.06 9.33 7.65 5.38 9.11 7.55 5.55<br />
16.0 22.0 12.5 9.41 3.53 12.2 9.32 4.18 11.7 9.05 4.87 11.3 8.85 5.13 10.9 8.64 5.46 10.6 8.51 5.64<br />
18.0 25.0 13.9 10.2 3.58 13.6 10.1 4.24 13.0 9.81 4.95 12.6 9.59 5.21 12.1 9.35 5.54 11.9 9.20 5.73<br />
19.0 27.0 14.6 10.6 3.64 14.3 10.5 4.31 13.6 10.1 5.03 13.2 9.90 5.30 12.7 9.65 5.64 12.4 9.49 5.82<br />
22.0 30.0 16.0 11.2 3.69 15.7 11.1 4.37 14.9 10.7 5.10 14.5 10.5 5.37 13.9 10.2 5.71 13.6 10.0 5.90<br />
24.0 32.0 16.6 11.4 3.74 16.3 11.3 4.43 15.5 10.9 5.17 15.0 10.6 5.45 14.5 10.3 5.79 14.1 10.1 5.98<br />
Model ABNH486RLAD[UB48 NRD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 11.1 9.01 3.83 10.9 8.93 4.54 10.4 8.68 5.29 10.1 8.50 5.57 9.68 8.32 5.93 9.46 8.20 6.12<br />
16.0 22.0 13.0 10.2 3.89 12.7 10.1 4.61 12.1 9.83 5.37 11.7 9.62 5.66 11.3 9.39 6.02 11.03 9.25 6.22<br />
18.0 25.0 14.5 11.1 3.94 14.2 11.0 4.68 13.5 10.7 5.45 13.1 10.4 5.74 12.6 10.2 6.11 12.3 10.0 6.31<br />
19.0 27.0 15.1 11.5 4.01 14.8 11.4 4.75 14.1 11.0 5.54 13.7 10.8 5.84 13.2 10.5 6.21 12.9 10.3 6.42<br />
22.0 30.0 16.6 12.2 4.06 16.3 12.0 4.82 15.5 11.6 5.61 15.0 11.4 5.91 14.5 11.0 6.29 14.1 10.8 6.50<br />
24.0 32.0 17.2 12.4 4.12 16.9 12.2 4.89 16.1 11.8 5.70 15.6 11.5 6.00 15.0 11.2 6.38 14.7 11.0 6.59<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 277
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH488D + ATNH48GMLED , UVNH486LLAD , ABNH486RLAD<br />
[UU48 U3D]+ [UT48 NMD] , [UV48 NLD] , [UB48 NRD]<br />
Model ATNH48GMLED[UT48 NMD]<br />
AFR 34<br />
Model UVNH486LLAD[UV48 NLD]<br />
AFR 36<br />
Model ABNH486RLAD[UB48 NRD]<br />
AFR 40<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 10.1 3.65 11.9 3.98 13.8 4.34 14.5 4.47 15.2 4.61 16.1 4.69 17.4 4.93 19.2 5.28<br />
18.0 9.8 3.77 11.6 4.12 13.4 4.49 14.0 4.62 14.7 4.76 15.5 4.85 16.8 5.10 18.6 5.46<br />
20.0 9.5 3.89 11.2 4.25 13.0 4.63 13.6 4.78 14.3 4.92 15.0 5.00 16.3 5.27 18.0 5.64<br />
22.0 9.2 4.02 10.8 4.39 12.5 4.78 13.1 4.93 13.8 5.08 14.5 5.16 15.7 5.44 17.4 5.82<br />
24.0 8.9 4.14 10.4 4.52 12.1 4.93 12.7 5.08 13.3 5.23 14.0 5.32 15.2 5.60 16.8 6.00<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 10.8 3.72 12.7 4.06 14.7 4.43 15.5 4.56 16.2 4.70 17.1 4.78 18.5 5.03 20.5 5.39<br />
18.0 10.5 3.84 12.3 4.20 14.3 4.58 15.0 4.72 15.7 4.86 16.6 4.94 17.9 5.20 19.8 5.57<br />
20.0 10.2 3.97 12.0 4.34 13.8 4.73 14.5 4.87 15.2 5.02 16.0 5.10 17.4 5.37 19.2 5.75<br />
22.0 9.8 4.10 11.5 4.48 13.3 4.88 14.0 5.03 14.7 5.18 15.5 5.27 16.8 5.54 18.5 5.94<br />
24.0 9.4 4.22 11.1 4.61 12.9 5.03 13.5 5.18 14.2 5.34 15.0 5.43 16.2 5.72 17.9 6.12<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 10.8 3.72 12.7 4.06 14.7 4.43 15.5 4.56 16.2 4.70 17.1 4.78 18.5 5.03 20.5 5.39<br />
18.0 10.5 3.84 12.3 4.20 14.3 4.58 15.0 4.72 15.7 4.86 16.6 4.94 17.9 5.20 19.8 5.57<br />
20.0 10.2 3.97 12.0 4.34 13.8 4.73 14.5 4.87 15.2 5.02 16.0 5.10 17.4 5.37 19.2 5.75<br />
22.0 9.8 4.10 11.5 4.48 13.3 4.88 14.0 5.03 14.7 5.18 15.5 5.27 16.8 5.54 18.5 5.94<br />
24.0 9.4 4.22 11.1 4.61 12.9 5.03 13.5 5.18 14.2 5.34 15.0 5.43 16.2 5.72 17.9 6.12<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
278 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Capacity tables<br />
• Cooling Capacity<br />
Models : AUUH608D + ATNH60GMLED , UVNH606LLAD , ABNH606RLAD<br />
[UU60 U3D]+ [UT60 NMD] , [UV60 NLD] , [UB60 NRD]<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Indoor Air<br />
Temperature<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 11.6 8.97 3.87 11.4 8.89 4.58 10.8 8.65 5.34 10.5 8.47 5.63 10.1 8.28 5.99 9.87 8.16 6.18<br />
16.0 22.0 13.5 10.2 3.93 13.2 10.1 4.65 12.6 9.79 5.42 12.2 9.58 5.71 11.8 9.35 6.08 11.5 9.21 6.28<br />
18.0 25.0 15.1 11.1 3.99 14.8 11.0 4.72 14.1 10.6 5.51 13.7 10.4 5.80 13.2 10.1 6.17 12.9 10.0 6.37<br />
19.0 27.0 15.8 11.5 4.05 15.5 11.3 4.80 14.7 11.0 5.60 14.3 10.7 5.90 13.8 10.4 6.28 13.4 10.3 6.48<br />
22.0 30.0 17.3 12.1 4.10 17.0 12.0 4.86 16.2 11.6 5.67 15.7 11.3 5.98 15.1 11.0 6.36 14.8 10.8 6.57<br />
24.0 32.0 18.0 12.3 4.16 17.6 12.2 4.94 16.8 11.8 5.76 16.3 11.5 6.06 15.7 11.1 6.45 15.3 10.9 6.66<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 40<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 11.6 8.86 3.87 11.4 8.78 4.58 10.8 8.54 5.34 10.5 8.37 5.63 10.1 8.18 5.99 9.87 8.07 6.18<br />
16.0 22.0 13.5 10.1 3.93 13.2 10.0 4.65 12.6 9.67 5.42 12.2 9.46 5.71 11.8 9.24 6.08 11.5 9.10 6.28<br />
18.0 25.0 15.1 10.9 3.99 14.8 10.8 4.72 14.1 10.5 5.51 13.7 10.3 5.80 13.2 10.0 6.17 12.9 9.84 6.37<br />
19.0 27.0 15.8 11.3 4.05 15.5 11.2 4.80 14.7 10.8 5.60 14.3 10.6 5.90 13.8 10.3 6.28 13.4 10.1 6.48<br />
22.0 30.0 17.3 12.0 4.10 17.0 11.8 4.86 16.2 11.4 5.67 15.7 11.2 5.98 15.1 10.9 6.36 14.8 10.7 6.57<br />
24.0 32.0 18.0 12.2 4.16 17.6 12.0 4.94 16.8 11.6 5.76 16.3 11.3 6.06 15.7 11.0 6.45 15.3 10.8 6.66<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
Indoor Air<br />
Temperature<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
Outdoor Air Temperature : °CDB<br />
20 25 32 35 40 43<br />
°CWB °CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI<br />
14.0 20.0 12.1 9.76 4.13 11.8 9.67 4.89 11.3 9.41 5.70 10.9 9.21 6.01 10.5 9.01 6.39 10.3 8.88 6.60<br />
16.0 22.0 14.1 11.1 4.19 13.8 11.0 4.97 13.2 10.6 5.79 12.8 10.4 6.10 12.3 10.2 6.49 12.0 10.0 6.70<br />
18.0 25.0 15.7 12.1 4.26 15.4 11.9 5.04 14.7 11.5 5.88 14.2 11.3 6.20 13.7 11.0 6.59 13.4 10.8 6.81<br />
19.0 27.0 16.5 12.5 4.33 16.1 12.3 5.13 15.4 11.9 5.98 14.9 11.7 6.30 14.3 11.4 6.70 14.0 11.2 6.92<br />
22.0 30.0 18.1 13.2 4.38 17.7 13.0 5.19 16.9 12.6 6.06 16.4 12.3 6.38 15.7 12.0 6.79 15.4 11.8 7.01<br />
24.0 32.0 18.8 13.4 4.45 18.4 13.2 5.27 17.5 12.8 6.15 17.0 12.5 6.47 16.3 12.1 6.89 16.0 11.9 7.11<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 279
Capacity tables<br />
• Heating Capacity<br />
Models : AUUH608D + ATNH60GMLED , UVNH606LLAD , ABNH606RLAD<br />
[UU60 U3D]+ [UT60 NMD] , [UV60 NLD] , [UB60 NRD]<br />
Model ATNH60GMLED[UT60 NMD]<br />
AFR 34<br />
Model UVNH606LLAD[UV60 NLD]<br />
AFR 40<br />
Model ABNH606RLAD[UB60 NRD]<br />
AFR 50<br />
• Symbol<br />
AFR : Air flow rate [m3 /min]<br />
DB : Dry bulb temperature [°C]<br />
WB : Wet bulb temperature [°C]<br />
TC : Total capacity [kW]<br />
SHC : Sensible capacity [kW]<br />
PI : Power Input [kW]<br />
(Comp.+ indoor fan motor+outdoor fan motor)<br />
5CSL0-06B<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 11.5 4.23 13.5 4.62 15.6 5.03 16.4 5.19 17.2 5.34 18.2 5.44 19.7 5.72 21.7 6.13<br />
18.0 11.1 4.37 13.1 4.78 15.1 5.21 15.9 5.36 16.7 5.53 17.6 5.62 19.1 5.92 21.0 6.34<br />
20.0 10.8 4.52 12.7 4.93 14.7 5.38 15.4 5.54 16.2 5.71 17.0 5.80 18.5 6.11 20.4 6.54<br />
22.0 10.4 4.66 12.2 5.09 14.2 5.55 14.9 5.72 15.6 5.89 16.5 5.99 17.8 6.31 19.7 6.75<br />
24.0 10.0 4.80 11.8 5.25 13.7 5.72 14.4 5.89 15.1 6.07 15.9 6.17 17.2 6.50 19.0 6.96<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 11.5 4.23 13.5 4.62 15.6 5.03 16.4 5.19 17.2 5.34 18.2 5.44 19.7 5.72 21.7 6.13<br />
18.0 11.1 4.37 13.1 4.78 15.1 5.21 15.9 5.36 16.7 5.53 17.6 5.62 19.1 5.92 21.0 6.34<br />
20.0 10.8 4.52 12.7 4.93 14.7 5.38 15.4 5.54 16.2 5.71 17.0 5.80 18.5 6.11 20.4 6.54<br />
22.0 10.4 4.66 12.2 5.09 14.2 5.55 14.9 5.72 15.6 5.89 16.5 5.99 17.8 6.31 19.7 6.75<br />
24.0 10.0 4.80 11.8 5.25 13.7 5.72 14.4 5.89 15.1 6.07 15.9 6.17 17.2 6.50 19.0 6.96<br />
Indoor Air<br />
Outdoor Air Temperature : °CWB<br />
Temperature(°C) -10 -5 0 2 4 6 10 15<br />
°CDB TC PI TC PI TC PI TC PI TC PI TC PI TC PI TC PI<br />
16.0 11.8 3.65 13.9 3.98 16.1 4.34 16.9 4.47 17.7 4.61 18.7 4.69 20.3 4.93 22.4 5.28<br />
18.0 11.4 3.77 13.5 4.12 15.6 4.49 16.4 4.62 17.2 4.76 18.1 4.85 19.6 5.10 21.7 5.46<br />
20.0 11.1 3.89 13.1 4.25 15.1 4.63 15.9 4.78 16.6 4.92 17.5 5.00 19.0 5.27 21.0 5.64<br />
22.0 10.7 4.02 12.6 4.39 14.6 4.78 15.3 4.93 16.0 5.08 17.0 5.16 18.4 5.44 20.3 5.82<br />
24.0 10.3 4.14 12.2 4.52 14.1 4.93 14.8 5.08 15.5 5.23 16.4 5.32 17.7 5.60 19.6 6.00<br />
• Notes<br />
1. All capacites are net, evaporator fan motor heat is<br />
deducted.<br />
2. Indicates rated capacity.<br />
3. Direct interpolation is permissible. Do not extrapolate<br />
4. Capacities are based on the following conditions:<br />
- Interconnecting Piping Length 7.5m<br />
- Level Difference <strong>of</strong> Zero.<br />
280 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B The coefficient <strong>of</strong> capacity change<br />
2.3.8 The coefficient <strong>of</strong> capacity change<br />
1) Rate <strong>of</strong> change in capacity due to the main piping length<br />
Rate <strong>of</strong> change in cooling capacity<br />
Main piping length(m)<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
10 15 20 30 35 40 45 50<br />
3.5kW 99.2 97.6 - - - - - -<br />
5.0/6.0kW 99.5 98.4 97.4 95.2 94.2 93.1 - -<br />
7.1kW 99.7 99.1 98.5 97.4 96.2 95.8 94.3 92.0<br />
8.0kW 99.8 99.5 98.4 97.4 96.3 95.2 94.1 93.1<br />
14.0/15.0kW 99.5 98.4 97.4 95.2 94.2 93.1 92.1 91.0<br />
Rate <strong>of</strong> change in heating capacity<br />
Main piping length(m)<br />
10 15 20 30 35 40 45 50<br />
3.5kW 98.8 96.4 - - - - - -<br />
Rate <strong>of</strong> change<br />
in capacity(%)<br />
5.0/6.0kW<br />
7.1kW<br />
8.0kW<br />
99.5<br />
99.7<br />
99.5<br />
98.4<br />
99.1<br />
98.4<br />
97.4<br />
98.5<br />
97.4<br />
95.2<br />
97.4<br />
95.2<br />
94.2<br />
96.8<br />
94.2<br />
93.1<br />
95.2<br />
93.1<br />
-<br />
94.3<br />
92.1<br />
-<br />
91.8<br />
91.1<br />
14.0/15.0kW 99.5 98.4 97.4 95.2 94.2 93.1 92.1 91.0<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 281
The coefficient <strong>of</strong> capacity change<br />
2) Calculation <strong>of</strong> actual system capacity<br />
① Outdoor unit rated capacity<br />
Qodu(rated) [from specification table]<br />
② Outdoor unit capacity at Ti, To temperature.<br />
Qodu(Ti, To) [from capacity table]<br />
③ Outdoor unit capacity coefficient factor<br />
F(Ti, To) = Qodu(Ti, To) / Qodu(rated)<br />
④ Piping correction factor [from capacity coefficient factor table]<br />
Fmain (length, elevation) for main piping length or elevation<br />
Fbranch (length, elevation) for branch piping length or elevation<br />
⑤ Individual indoor unit combinational capacity<br />
Qidu (combi) = Qodu(rated) x Qidu(rated) / Qidu(rated-total)<br />
⑥ Individual indoor unit actual capacity<br />
Qidu (actual) = Qodu(combi) x F(Ti, To) x Fmain (length, elevation) x Fbranch (length, elevation)<br />
Exam<strong>pl</strong>e) • Outdoor unit model : AUUH368D[UU37 UED]<br />
• Indoor units(ATNH36GNLED) : 10kW<br />
• Outdoor temperature : 32.0°CDB<br />
• Indoor temperature: 19.0°CWB<br />
• Main piping length(O/D to BD) : 30m<br />
• Indoor unit actual cooling capacity<br />
- Qodu(rated) : 10.0 kW<br />
- Qodu(Ti, To) : 10.3 kW<br />
- F(Ti, To) : 103%<br />
- Fmain(length, elevation) = 97.4%(by table)<br />
- Qidu(actual) =10.0kW x 1.03 x 0.974 = 10.03kW<br />
5CSL0-06B<br />
282 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Operation range<br />
2.3.9 Operation range<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
46<br />
43<br />
21<br />
-5<br />
Cooling<br />
Operative<br />
Continuous<br />
operation<br />
18 32<br />
Indoor Unit [°C DB]<br />
❈ Although low ambient kit is installed, in<br />
case outdoor temperature goes below 0°C,<br />
the cooling capacity can be dropped and<br />
operation characteristics can be slightly<br />
different.<br />
Outdoor<br />
Unit<br />
[°C DB]<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 283<br />
24<br />
-5<br />
-10<br />
Warming up<br />
Operation<br />
Heating<br />
Continuous<br />
operation<br />
Operative<br />
16 30<br />
Indoor Unit [°CDB]<br />
Operative:<br />
Intermittent operation due to the operation<br />
conditions (indoor/outdoor temperature humidity,<br />
and load) can cause<br />
the heating capacity to drop.
Electric characteristics<br />
2.3.10 Electric characteristics<br />
Outdoor Unit<br />
Power Compressor OFM<br />
5CSL0-06B<br />
Model Type Hz Voltage Voltage range MCA MOP MSC RLA kW FLA<br />
AUUH126D<br />
[UU12 ULD]<br />
AUUH186D<br />
[UU18 UED]<br />
AUUH246D<br />
[UU24 UED]<br />
AUUH306D<br />
[UU30 UED]<br />
AUUH368D<br />
[UU37 UED]<br />
AUUH488D<br />
[UU48 U3D]<br />
AUUH608D<br />
[UU60 U3D]<br />
Non inverter 50<br />
220-240<br />
380-415<br />
Notes :<br />
1. Voltage range<br />
Voltage sup<strong>pl</strong>ied to the unit terminals should be within the<br />
minimum and maximum range<br />
2. Maximum allowable voltage unbalance between phase is 2 %<br />
3. MCA / MOP<br />
MCA = (1.25 x Load1) + Load2 + Load3<br />
MOP = (2.25 x Load1) + Load2 + Load3<br />
- Load1 : Rated running current <strong>of</strong> largest motor<br />
(compressor or other motor)<br />
- Load2 : sum <strong>of</strong> current for all other motors<br />
- Load3 : any other load rated 1.0A or more<br />
4. Select wire spec. based on the MCA<br />
5. Recommended circuit breaker is ELCB (Earth Leakage circuit<br />
breaker)<br />
6. MSC & RLA are measured as the compressor only test<br />
condition.<br />
7. MSC values<br />
Min.: 198<br />
Max.: 264<br />
Min : 352<br />
Maxi :457<br />
7.50 13.50 24.00 6.00 0.10 0.51<br />
11.25 20.25 35.00 9.00 0.13 0.70<br />
13.75 24.75 62.00 11.00 0.13 0.70<br />
20.88 37.58 82.00 16.70 0.13 0.70<br />
9.13 15.63 47.00 6.50 0.16 1.00<br />
12.77 22.07 63.00 9.30 0.25 1.14<br />
13.14 22.74 74.00 9.60 0.25 1.14<br />
8. RLA is measured during each individual compressor test<br />
condition.<br />
9. OFM is measured as the outdoor unit test condition<br />
(Exam<strong>pl</strong>e) Selection <strong>of</strong> proper circuit breaker<br />
① Model : AUUH126D[UU12 ULD]<br />
- Rated running current : 6.0A (refer to spec. sheet)<br />
② MCA = (1.25 x Load1) + Load2 + Load3<br />
= (1.25 x 6.0) + 0 + 0 = 7.5A<br />
③ MOP = (2.25 x Load1) + Load2 + Load3<br />
= (2.25 x 6.0) + 0 + 0 = 13.5A<br />
→ Finally select circuit breaker 15A (Min. circuit breaker is 15A)<br />
MCA : Minimum Circuit Amperes (A)<br />
MOP : Maximum rating over current protective device<br />
MSC : Maximum Starting Current<br />
RLA : Rated Load Amperes (A)<br />
OFM : Outdoor Fan Motor<br />
kW : Fan Motor rated output (kW)<br />
FLA : Full Load Amperes (A)<br />
284 Outdoor unit - Non inverter Single A (1Ø, 3Ø)
5CSL0-06B Field wiring diagrams<br />
2.3.11 Field wiring diagrams<br />
1. All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
2. Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the current as required by the air conditioner.<br />
3. Feed the power source to the unit via a distribution switch board designed for this purpose.<br />
4. The terminal screws inside the control box may be loose due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can overload and damage electrical components.)<br />
5. Always ground the air conditioner with a grounding wire and connector to meet the LOCAL REGULATION.<br />
L N<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
L<br />
Circuit breaker<br />
Fuse<br />
Power cable 3/5 core 2.5/3.5mm 2<br />
(Including earth)<br />
N<br />
G<br />
(1 PHASE)<br />
1(L) 2(N) 3<br />
Terminal block indoor<br />
Outdoor unit<br />
Terminal Block outdoor<br />
1(L) 2(N) 1(L) 2(N) 3<br />
Transmission line<br />
R S T N<br />
Circuit breaker<br />
Fuse<br />
Power sup<strong>pl</strong>y<br />
Main switch<br />
Power cable 5 core x 2.5mm 2<br />
(Including earth)<br />
Notes:<br />
. All wirings, components and materials to be procured on the site should be according to the standard<br />
. Use copper conductor only<br />
. Install circuit breaker for safety<br />
. Unit should be grounded in com<strong>pl</strong>iance with the ap<strong>pl</strong>icable local and national codes<br />
. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />
Outdoor unit<br />
Outdoor unit - Non inverter Single A (1Ø, 3Ø) 285<br />
R S<br />
T N<br />
(3 PHASE)<br />
Terminal Block outdoor<br />
R S T N 1(L) 2(N) 3 4 5<br />
1(L) 2(N) 3<br />
Terminal b lock indoor<br />
Transmission<br />
cable
Sound levels<br />
2.3.12 Sound levels<br />
Overall<br />
Sound Pressure Level (dB re 20μPa)<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
1m<br />
Sound Pressure Level<br />
Sound Pressure Level (dB re 20μPa)<br />
20<br />
NC-25<br />
NC-20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
Microphone<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
1m<br />
Sound Pressure Level (dB re 20μPa)<br />
Sound Pressure Level (dB re 20μPa)<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
Notes:<br />
- Sound measured at 1m away from the center <strong>of</strong> the unit.<br />
- Data is valid at free field condition.<br />
- Data is valid at nominal operation condition.<br />
- Reference accoustic pressure 0dB=20μPa<br />
- Sound level will vary depending on a range <strong>of</strong> factors such as<br />
the construction(acoustic absorption coefficient) <strong>of</strong> particular<br />
room in which the equipment is installed.<br />
- The operating conditions are assumed to be standard.<br />
AUUH126D [UU12 ULD] AUUH186D [UU18 UED] AUUH246D[UU24 UED]<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
5CSL0-06B<br />
286 Outdoor unit - Non inverter Single A (1Ø, 3Ø)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
Sound Pressure Level (dB re 20 Pa)<br />
Sound Pressure Level (dB re 20μPa)<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
NC-15<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
AUUH306D[UU30 UED] AUUH368D[UU37 UED] AUUH488D[UU48 U3D]<br />
AUUH608D[UU60 U3D]<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
Approximate<br />
Hearing<br />
Threshold<br />
63 125 250 500 1000 2000 4000 8000<br />
Octave Band Center Frequency (Hz)<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20<br />
NC-15<br />
NC-70<br />
NC-65<br />
NC-60<br />
NC-55<br />
NC-50<br />
NC-45<br />
NC-40<br />
NC-35<br />
NC-30<br />
NC-25<br />
NC-20
Part 3 Design and installation<br />
1. General installation guideline ............................................................288<br />
1.1 Installation process & Guideline .......................................................................288<br />
1.2 Checking the drawing ........................................................................................289<br />
2. Guideline for each installation process ............................................290<br />
2.1 Sleeve and inserting work..................................................................................290<br />
2.2 Refrigerant piping work......................................................................................292<br />
2.3 Drain piping work ..............................................................................................298<br />
2.4 Insulation work...................................................................................................304<br />
2.5 Electrical work....................................................................................................307<br />
2.6 Air tight test........................................................................................................310<br />
2.7 Vacuum drying works.........................................................................................312<br />
2.8 Additional charge <strong>of</strong> refrigerant..........................................................................316<br />
2.9 Trail test run operation .......................................................................................317<br />
3. Installation <strong>of</strong> indoor unit ..................................................................318<br />
3.1 Safety precautions .............................................................................................318<br />
3.2 Ceiling cassette 4-way.......................................................................................322<br />
3.3 Ceiling and floor, Ceiling suspended only..........................................................330<br />
3.4 Ceiling concealed duct - High static pressure....................................................341<br />
3.5 Console (Floor stand) ........................................................................................347<br />
4. Installation <strong>of</strong> outdoor Unit ...............................................................355<br />
4.1 Safety precautions .............................................................................................355<br />
4.2 Introduction ........................................................................................................359<br />
4.3 Foundation.........................................................................................................360<br />
4.4 Settlement <strong>of</strong> the outdoor unit............................................................................362<br />
4.5 Selection <strong>of</strong> the best location.............................................................................362<br />
4.6 Clearance space................................................................................................364<br />
4.7 Outdoor unit piping ............................................................................................367<br />
4.8 Outdoor unit installation requirments .................................................................368<br />
4.9 Outdoor unit cabin .............................................................................................372<br />
Design and installation 287
Installation process & Guideline 5CSL0-06B<br />
1. General installation guideline<br />
1.1 Installation process & Guideline<br />
Striking a balance between system installation & general construction work.<br />
Construction work Air conditioning work<br />
Fitting <strong>of</strong> steel sleeves<br />
Moulding box and<br />
reinforcement work<br />
Preparation <strong>of</strong><br />
contract drawing<br />
Sleeve and insert work<br />
Removal moulding boxes Installation <strong>of</strong> indoor unit<br />
Ceiling preparations<br />
Building ro<strong>of</strong>top<br />
Refrigerant piping work<br />
Drain piping work<br />
Duct work<br />
Insulation work<br />
Electrical work<br />
Outdoor unit foundation work<br />
Installation <strong>of</strong> outdoor unit<br />
Air tight test<br />
Vacuum drying<br />
Additional charge <strong>of</strong> refrigerant<br />
Fit decoration panels<br />
Cleaning inside and outside Test run<br />
Energization<br />
Setting sleeve and insert work details<br />
T.A.B and final report<br />
Transfer to customer with<br />
ex<strong>pl</strong>anation<br />
1. The division <strong>of</strong> the work should be thoroughly clarified.<br />
2. keep a constant check on the progress <strong>of</strong> the construction work to avoid deviations from the air conditioning<br />
work schedule.<br />
288 General installation guideline
5CSL0-06B<br />
1.2 Checking the drawing<br />
Installation procedure Remarks<br />
Determination <strong>of</strong> work scope<br />
Preparation <strong>of</strong> contract drawings<br />
Sleeve and insert works<br />
Installation <strong>of</strong> indoor units<br />
Refrigerant piping works<br />
Drain pipe works<br />
Duct works<br />
Insulation works<br />
Electrical work<br />
Outdoor unit foundation works<br />
Installation <strong>of</strong> outdoor units<br />
Air tight test<br />
Vacuum drying<br />
Additional charge <strong>of</strong> refrigerant<br />
Fit decoration panels<br />
Test run<br />
Transfer to customer with ex<strong>pl</strong>anation<br />
Checking the drawing<br />
Check and confirm required loads calculation,<br />
model selection, drawings etc.<br />
Make a relationship between outdoor ,indoor<br />
controller and option connection clear.<br />
(prepare control circuit diagram)<br />
Determine sleeve position, size and<br />
counts as required<br />
Check model name to make sure the fitting is<br />
made correctly<br />
Special attention to dryness , cleanness and<br />
tightness<br />
Make sure that the drain pipe diameter is<br />
big enough and adjust it to downward gradient<br />
Make sure airflow is sufficient<br />
Make sure no gap is left where the<br />
insulating materials are joined<br />
Multi<strong>pl</strong>e core cable must not be used<br />
(suitable cable should be selected)<br />
The foundation must be vibration pro<strong>of</strong> and<br />
in level<br />
Avoid airflow short circuit and ensure<br />
sufficient space is allowed for servicing<br />
For 24 hours at 3.8MPa(R410a) or 2.8MPa(R22)<br />
there must be no drop in pressure<br />
Less than 5 Torr (At least more than 1hr)<br />
Charge the refrigerant accurately by using a<br />
charging cylinder<br />
Make sure there are no gaps left between<br />
facing materials used on the ceiling<br />
Follow the testing operation check sheet<br />
Ex<strong>pl</strong>ain to customer or operator the manual<br />
etc<br />
General installation guideline 289
Sleeve and insert work 5CSL0-06B<br />
2. Guideline for each installation process<br />
2.1 Sleeve and insert work<br />
2.1.1 Positioning <strong>of</strong> the pipe holes<br />
1. The through holes for the drain piping should be positioned<br />
such that pipes have a downward gradient (the<br />
gradient must be at least 1/100.The thickness <strong>of</strong> the insulating<br />
materials must also be taken into consideration.)<br />
2. The diameter <strong>of</strong> the through holes for the refrigerant piping<br />
should include an allowance for the thickness <strong>of</strong> the<br />
heat insulation materials.<br />
3. Attention should be paid to the construction <strong>of</strong> the beam<br />
themselves since there are sometimes parts <strong>of</strong> the beam<br />
which cannot be used to accommodate through holes.<br />
2.1.2 Selection <strong>of</strong> sleeve<br />
1. Sleeve work should be performed to make a space for<br />
passing pipe and wire through the wall or ground under<br />
construction.<br />
For exam<strong>pl</strong>e if gas pipe and liquid pipe is 12.7mm , 6.35mm<br />
the sleeve diameter is minimum 79.05mm .<br />
Gas pipe diameter 12.7mm<br />
Liquid pipe diameter 6.35mm<br />
Insulation thickness(gas pipe) 10mm x 2<br />
Insulation thickness(liquid pipe) 10mm x 2<br />
20mm sur<strong>pl</strong>us 20mm<br />
Total sleeve diameter 79.05mm<br />
* Assumption : Gas pipe insulation thickness and liquid pipe<br />
insulation thickness is 10mm and 10mm respectively<br />
2.1.3 Sleeve type<br />
NOTE<br />
Pipe<br />
Sleeve<br />
Insulation<br />
Sleeve type should be considered as per local regulation &<br />
laws.<br />
NOTE<br />
CAUTION<br />
1. In high voltage generation <strong>pl</strong>aces, water-pro<strong>of</strong> flexible<br />
conduit should be used. (in substation room, in elevator<br />
room)<br />
2. Conduit should be chosen in accordance with electrical<br />
installation regulation.<br />
Cable conduit should be considered under the local regulation<br />
& laws.<br />
2.1.4 Insert work and support work<br />
An insert is a metal tool which is inserted into a floor or<br />
beam before the concrete is set such that fittings such as<br />
duct , pipes or suspension bolts for hanging units can be fitted<br />
into the <strong>pl</strong>ace later. The positioning <strong>of</strong> the inserts must<br />
be decided early.<br />
1. Insert work<br />
Exam<strong>pl</strong>e : Through holes in a reinforced concrete beam<br />
Molding box<br />
290 Guideline for each installation process<br />
Embedding<br />
depth h<br />
Polyblock<br />
Nail securing<br />
molding box<br />
Suspension bolt
5CSL0-06B<br />
2. Support work.<br />
Insulated U-bolt type supporting<br />
Bolt<br />
Saddle supporting<br />
CAUTION<br />
1.5t<br />
<strong>pl</strong>ate<br />
a) Supporting with insulated pipe<br />
Foam<br />
resin<br />
Sleeve and insert work<br />
Guideline for each installation process 291<br />
PVC<br />
PVC<br />
U-bolt supporting 0-ring band supporting<br />
To prevent<br />
Insulation from<br />
pressing, and<br />
lagging, cover<br />
can be used.<br />
Sheathing<br />
pipe<br />
Supporting interval 1.5~2.0m<br />
Insulated O-ring band type supporting<br />
During saddle supporting work, insulation should not be pressed by saddle as this can lead to tearing <strong>of</strong> insulation and<br />
thus falling <strong>of</strong> condensed water during product operation.<br />
B) Down stopper supporting<br />
Hexagonal nut<br />
One point supporter (200kg)<br />
O-ring band<br />
Plate nut<br />
Welding<br />
Down stopper<br />
O-ring<br />
band<br />
lags<br />
Insulated<br />
Supporting band<br />
Sheathing<br />
pipe<br />
Bolt<br />
Welding<br />
Insulated<br />
Supporting band<br />
Refrigerant pipe
Refrigerant piping work 5CSL0-06B<br />
2.2 Refrigerant piping work<br />
2.2.1 Flaring work<br />
NOTE<br />
CAUTION<br />
Flare connection and procedure<br />
1. Stiffened pipe must always be annealed at least once<br />
prior to the flaring work.<br />
A<br />
2. A pipe cutter must be used to cut the pipe.<br />
(A large pipe cutter must be used where<br />
the pipe has a large diameter. When cutting<br />
a pipe which is too big for the pipe cutter a<br />
metal saw may be used but care must be<br />
taken to ensure that the debris from sawing<br />
does not get into the pipe.)<br />
D<br />
CAUTION<br />
Choice <strong>of</strong> material for refrigerant piping<br />
Copper pipe selection<br />
a. The wall thickness <strong>of</strong> the refrigerant piping should com<strong>pl</strong>y with relevant local and national regulation for<br />
R410A the design pressure is 3.8MPa.(38.7kgf/cm2 )<br />
b. If not, we recommend to use with phosphorus deoxidized copper type<br />
c. Generally used copper pipe specifications as follows;<br />
Size(ø)mm<br />
Torque<br />
kg·f.m R22<br />
Thickness<br />
R410A<br />
6.35 1.80~2.50 0.7 0.8<br />
9.52 3.40~4.20 0.8 0.8<br />
12.70 5.50~6.60 0.8 0.8<br />
15.88 6.30~8.20 1.0 1.0<br />
19.05 9.90~12.1 1.0 1.0<br />
* Never use the pipe which is mixed scrap or a pipe used somewhere else<br />
The method how to distinguish the pipe mixed scarp : check the oxidization evidence after leaving the pipe for 24hour.<br />
External diameter <strong>of</strong> pipe D<br />
(in) (mm)<br />
1. Burrs should be carefully removed.<br />
2. 2 spanners should be used to grip the pipe.<br />
3. The flare nut must be inserted before starting the flaring operation.<br />
4. The appropriate amount <strong>of</strong> torque should be used to tighten the flare nut.<br />
5. Check that there is no superficial damage to the surface <strong>of</strong> the flare.<br />
H<br />
3. Set the flaring tool to make sure the flare size remains<br />
within the prescribed limits.<br />
4. Coat the inner and outer surface <strong>of</strong> the<br />
flare with refrigerator oil (Ester or ether<br />
oil).<br />
(this ensures that the flare nut passes<br />
smoothly, preventing the pipe Oil<br />
Oil<br />
from twisting.)<br />
Do not use SUNISO-4GS oil.<br />
Pipe widening dimension A<br />
(mm)<br />
Required flare height H<br />
(mm)<br />
1/4 6.35 8.6~9.0 1.1~1.3<br />
3/8 9.52 12.6~13.0 1.5~1.7<br />
1/2 12.7 15.8~16.2 1.6~1.8<br />
5/8 15.88 19.0~19.4 1.6~1.8<br />
3/4 19.05 22.9~23.3 1.9~2.1<br />
292 Guideline for each installation process
5CSL0-06B Refrigerant piping work<br />
2.2.2 Pipe connection and flaring works<br />
NOTE<br />
1. After installation com<strong>pl</strong>etion make sure to open the<br />
valve. operating the unit with the valve shut <strong>of</strong>f will<br />
destroy the compressor (Refer to the Additional<br />
refrigerant charge detail information)<br />
2. Use R410A to add refrigerant. All field piping must be<br />
installed by a licensed refrigeration technician<br />
3. Must com<strong>pl</strong>y with local and national standard<br />
regulations.<br />
1) Connecting the piping to the indoor unit<br />
and drain hose to drain pipe<br />
① Align the center <strong>of</strong> the piping and sufficiently tighten the<br />
flare nut by hand.<br />
② Tighten the flare nut with a wrench. Wrap the insulation<br />
material around the connecting portion.<br />
Outside diameter(Ø) Torque<br />
mm inch kg.f.m<br />
6.35 1/4 1.80~2.50<br />
9.52 3/8 3.40~4.20<br />
12.7 1/2 5.50~6.60<br />
15.88 5/8 6.30~8.20<br />
19.05 3/4 9.90~12.1<br />
2) Wrap the insulation material around the<br />
connecting portion.<br />
① Overlap the connection pipe insulation material and the<br />
indoor unit pipe insulation material. Bind them together<br />
with vinyl tape so that there is no gap.<br />
② Wrap the area which accommodates the rear piping<br />
housing section with vinyl tape.<br />
③ When the piping is passed through a tray, duct work or a<br />
sleeve the insulation wrapping on the pipe is not required.<br />
3) Close up a socket out <strong>of</strong> use with a brass cap.<br />
① Align the center <strong>of</strong> the piping and sufficiently tighten the<br />
brass cap by hand.<br />
② Tighten the brass cap with a wrench.<br />
③ Wrap the area contacted with insulation.<br />
Indoor unit tubing Flare nut Pipes<br />
2.2.3. SVC valve fitting<br />
Cautions on handling SVC valve<br />
• The figure below shows the name <strong>of</strong> each part required in<br />
handling SVC valve. At the time <strong>of</strong> shipment, SVC valve<br />
is closed.<br />
• If only a torque wrench is used to loosen or tighten the<br />
flare nut, the side <strong>pl</strong>ate may be distorted. Make sure to fix<br />
SVC valve with a spanner, then loosen or tighten the flare<br />
nut with a torque wrench.<br />
• When it is expected that the operating pressure will be<br />
low (for exam<strong>pl</strong>e, when cooling will be performed while<br />
the outside air tem-perature is low), seal sufficiently the<br />
flare nut in SVC valve on the gas line with silicon sealant<br />
to prevent freezing.<br />
[Valve operation method]<br />
Prepare hexagon wrenches (whose size is 4 mm).<br />
How to open the stop valve<br />
1. Insert a hexagon wrench into the valve stem, and turn<br />
the valve stem counterclockwise.<br />
2. When the valve stem cannot be turned any more, stop<br />
turning. Now, the valve is open.<br />
Guideline for each installation process 293<br />
Wrench<br />
Indoor unit tubing<br />
Connection pipe<br />
Open-end wrench (fixed)<br />
Flare nut<br />
Vinyl tape(narrow)<br />
Connection pipe<br />
Vinyl tape (wide) Wrap with vinyl tape<br />
Connecting cable<br />
90°±2°<br />
45°±2°<br />
Flare shape<br />
Indoor unit pipe<br />
Pipe<br />
R0.4~0.8mm
Refrigerant piping work 5CSL0-06B<br />
How to close the stop valve<br />
1. Insert a hexagon wrench into the valve stem, and turn the<br />
valve stem clockwise.<br />
2. When the valve stem cannot be turned any more, stop<br />
turning. Now, the valve is closed.<br />
Service port<br />
Valve stem<br />
Valve cap<br />
Field piping<br />
connection part<br />
Silicon sealant<br />
(Take care not to generate cavity.)<br />
Opening direction Opening direction<br />
<br />
Cautions on handling the valve cap<br />
• The valve is sealed in the arrow area. Take care not to<br />
damage the arrow area.<br />
Valve cap<br />
SVC valve<br />
(valve cap attachment area)<br />
• After handling the valve, make sure to tighten the valve<br />
cap securely.<br />
Liquid line Gas line<br />
3.4~4.2 m-kgf 6.3~8.2 m-kgf<br />
Cautions on handling the service port<br />
• Use charge hose equipped with push in the work.<br />
• After the work, make sure to tighten the valve cap securely.<br />
Tightening torque.....8.5~10.3 ft·lbf<br />
Do not ap<strong>pl</strong>y any force to the valve cap<br />
Using a spanner on the valve cap and the valve body could<br />
cause a refrigerant leak.<br />
Oil Trap<br />
• Necessity <strong>of</strong> trap<br />
Since there is fear <strong>of</strong> the oil held inside the riser piping<br />
flowing back into the compressor when stopped and causing<br />
liquid compression phenomenon, or cases <strong>of</strong> deterioration<br />
<strong>of</strong> oil return, it will be necessary to provide a trap at an<br />
appropriate <strong>pl</strong>ace in the riser gas piping.<br />
• Trap installation spacing<br />
NOTE<br />
Spanner<br />
prohibition to<br />
valve cap and<br />
body part<br />
SVC valve <strong>of</strong> two<br />
hands method<br />
SVC valve <strong>of</strong> one<br />
hands method<br />
294 Guideline for each installation process<br />
Spanner<br />
Torque<br />
wrench<br />
Torque<br />
wrench<br />
A trap is not necessary when the outdoor unit is installed<br />
in a higher position than the indoor unit.
5CSL0-06B<br />
2.2.4 Brazing work<br />
CAUTION<br />
Brazing <strong>of</strong> refrigerant piping :<br />
The following precaution should be taken.<br />
1. Do not use flux when brazing copper to copper<br />
refrigerant piping.<br />
(Particularly for the HFC refrigerant piping)<br />
Therefore, use the phosphor copper brazing filler metal<br />
(BCuP) which does not require flux.<br />
(Flux has extremely harmful influence on refrigerant piping<br />
systems. For instance, if the chlorine based flux is<br />
used, it will cause pipe corrosion or, in particular, if the<br />
flux contains fluorine, it will damage the refrigerant oil.)<br />
1. Niorogen flushing method (During brazing)<br />
CAUTION<br />
Taping<br />
Brazing section<br />
Copper pipe 1/4<br />
Packless<br />
valve<br />
Outdoor unit<br />
High<br />
pressure hose<br />
Pipe<br />
Packless<br />
valve<br />
Pressure regulator<br />
Nitrogen cylinder<br />
Hose<br />
Pressure<br />
regulator<br />
Nitrogen cylinder<br />
Nitrogen Brazing<br />
a. This procedure is designed to prevent formation <strong>of</strong><br />
oxidation film by filling piping with inert gas. Note that<br />
excessive gas pressure will generate pinholes at<br />
brazed points. (Nitrogen gas: Sup<strong>pl</strong>y pressure<br />
0.05~0.1kg/cm 2 G)<br />
b. When sup<strong>pl</strong>ying inert gas, be sure to open one end <strong>of</strong><br />
piping.<br />
CAUTION<br />
Refrigerant piping work<br />
If brazing work is carried out without passing nitrogen gas<br />
through the pipes then it allows the formation <strong>of</strong><br />
oxidation bubbles on the inside surface <strong>of</strong> the pipes.<br />
These oxidation bubbles are then carried along inside the<br />
pipes to cause damage to various members <strong>of</strong> the system<br />
such as valve or compressors and the system ceases to<br />
function properly.<br />
In order to avoid this problem nitrogen is passed through<br />
the pipe while the soldering work is being carried out.<br />
This operation work is known as nitrogen<br />
re<strong>pl</strong>acement.(Air is re<strong>pl</strong>aced by nitrogen)<br />
This is standard work during all brazing works.<br />
CAUTION<br />
Water enters Plaster enters<br />
Make sure to keep the connecting piping dry (away<br />
from water) , clean (away from dust) , and air tight<br />
(avoid refrigerant leakage)<br />
Pipe bending<br />
Annealed copper pipe with small diameter (Ø6.35 or<br />
Ø9.52) can be easily bent manually. In this case, secure<br />
large R (radius) for the bend section and gradually bend<br />
pipe. If annealed copper pipe is large in diameter<br />
(Ø15.88 or over), bend pipe with bender. Use bender<br />
appropriate for the pipe diameter.<br />
(Direction <strong>of</strong> Nitrogen gas.)<br />
Nitrogen Brazing<br />
Guideline for each installation process 295<br />
N2
Refrigerant piping work 5CSL0-06B<br />
Brazing work should be carried out either downwards or sideways.<br />
An upward direction should be avoided wherever possible(to prevent leakage).<br />
Piping size<br />
6.35<br />
9.52<br />
12.7<br />
15.9<br />
19.1<br />
22.2<br />
25.4<br />
31.8<br />
38.1<br />
44.5<br />
CAUTION<br />
Table 1: Correlation <strong>of</strong> nozzle tip and size <strong>of</strong> refrigeration piping<br />
# 200<br />
over 10mm<br />
(Expending pipe brazing)<br />
(Flare part brazing)<br />
N2<br />
N2<br />
over 10mm<br />
(Pipe brazing with socket)<br />
(Butt-brazing)<br />
Nozzle tip No. Brazing filler diameter Ø<br />
# 225 # 250 # 315 # 400 # 450 # 500 1.6 2.4 3.2<br />
1. Generally expending pipe brazing is performed with pan-coil type copper pipe, and socket blazing is<br />
performed with straight copper pipe.<br />
2. Do not perform flare part brazing or butt-brazing.<br />
3. Brazing should be performed on welding table.<br />
4. Any dust should enter in the pipe while brazing.<br />
5. Distance <strong>of</strong> copper pipe support spacing is within 1~2m<br />
6. The copper pipe should not be secured directly by metal brackets.<br />
296 Guideline for each installation process<br />
N2<br />
N2
5CSL0-06B<br />
2.2.5 Refrigerant pipe flushing<br />
Flushing is a method <strong>of</strong> cleaning extraneous matter out <strong>of</strong> pipes using pressurized gas.<br />
NOTE<br />
Refrigerant pipe flushing <strong>of</strong> 3 major effects<br />
1. Removal <strong>of</strong> oxidation bubbles formed inside copper pipes when “nitrogen re<strong>pl</strong>acement is insufficient”<br />
during soldering work<br />
2. Removal <strong>of</strong> extraneous material and moisture from pipes when covering has been insufficient<br />
3. Checks connections in pipes linking outdoor and indoor units (Both liquid and gas pipes)<br />
① Set pressure regulator on nitrogen cylinder.<br />
② Connect the charge hose from pressure regulator to<br />
service port on the liquid pipe side <strong>of</strong> the outdoor unit<br />
before its connection to BD unit or indoor unit.<br />
③ Open the main valve on the nitrogen cylinder and set<br />
the pressure regulator to 0.5MPa.<br />
④ Ensure that nitrogen is flowing through the pipe properly.<br />
⑤ For flushing block the end <strong>of</strong> the pipe with wood insulation<br />
block.<br />
⑥ When the pressure becomes great remove the block<br />
quickly.<br />
⑦ Do step 6 & 7 repeatedly till cleanness is ensured.<br />
⑧ Connect the charge hose from pressure regulator to<br />
service port on the gas pipe side <strong>of</strong> outdoor unit before<br />
its connection to BD unit or indoor unit.<br />
⑨ Flow the steps 3, 4, 5, 6, 7.<br />
⑩ In case <strong>of</strong> BD unit system, before connecting to indoor<br />
units, each pipe should be flushed individually.<br />
⑪ Flow the steps 3, 4, 5, 6, 7.<br />
CAUTION<br />
After welding the pipe, nitrogen flushing is strongly<br />
recommended.<br />
Nitrogen<br />
Nitrogen<br />
Primary<br />
side<br />
Nitrogen<br />
Pressure regulator<br />
Gas pressure <strong>of</strong> 0.5 MPa<br />
Refrigerant piping work<br />
Guideline for each installation process 297<br />
Lo Hi<br />
Lo Hi<br />
Wood Insulation<br />
Lo Hi<br />
Secondary<br />
side 0.5 MPa<br />
Taping
Drain piping work 5CSL0-06B<br />
2.3 Drain piping work<br />
The purpose <strong>of</strong> drain piping is to prevent damage <strong>of</strong> products and ceiling materials by proper draining <strong>of</strong> dew condensation<br />
which is generated from the evaporator <strong>of</strong> indoor unit when the hot vapors come in contact with the evaporator.<br />
1. Ap<strong>pl</strong>ication<br />
Pipes for draining water generated from indoor unit on cooling operation<br />
Specification for drain piping<br />
Single A<br />
Type<br />
Cassette 4 way<br />
Duct<br />
Ceiling and floor<br />
Suspended only<br />
[Reference Table] Drain amount per capacity<br />
kW<br />
2.04<br />
2.33<br />
2.91<br />
4.36<br />
5.82<br />
7.28<br />
8.73<br />
10.2<br />
11.6<br />
14.6<br />
Air flow rate<br />
(CMH)<br />
8<br />
8.5<br />
10.5<br />
11.5<br />
17<br />
19<br />
21<br />
23<br />
25<br />
34<br />
Drain pipe<br />
diameter<br />
(External/<br />
Internal)<br />
Ø32/25mm<br />
Ø32/25mm<br />
-<br />
Drain<br />
pump<br />
Standard<br />
Accessory<br />
Remark<br />
400 (0.4)<br />
Indoor temp. : 26C DB<br />
Indoor humidity RH : 85%<br />
Outlet temp. :14C DB<br />
Outlet temp. RH: 50%<br />
298 Guideline for each installation process<br />
-<br />
Drain pump<br />
discharge<br />
head (mm)<br />
700<br />
700<br />
- -<br />
-<br />
-<br />
Drain amount<br />
(lpm)<br />
0.128<br />
0.137<br />
0.169<br />
0.185<br />
0.273<br />
0.305<br />
0.337<br />
0.369<br />
0.402<br />
0.546<br />
-<br />
Drain amount<br />
(at 10mm height)<br />
cm 3/min (lpm)<br />
400 (0.4)<br />
-
5CSL0-06B<br />
2.3.1 Drain pipe slope and support<br />
Drain piping work<br />
• Slope gradient for drain should be (1/50~1/100mm) and PVC pipes should be used.<br />
• Support hanger should be at 1~1.5m interval to prevent from loosing and dropping.<br />
• Drain pipe insulation<br />
: The inside temperature <strong>of</strong> drain pipe is about 10°C. When high temperature and humidity air touches the surface <strong>of</strong><br />
pipe, dew condensation occurs. To prevent that, drain pipe keeps warm using insulation with polyethylene 10mm<br />
thickness.<br />
Indoor unit<br />
Or<br />
Drain pan<br />
1. Ap<strong>pl</strong>ication<br />
Refrigerant pipe length contracts and expands on heating and cooling repeatedly. So supporting work is needed not to<br />
hinder each copper pipe connection part.<br />
2. Supporting distance for common drain pipe<br />
[Table]The interval <strong>of</strong> the supporting hanger for drainage pipe<br />
Gradient <strong>of</strong> at least 1 / 50 ~ 1 / 100<br />
Pipe diameter<br />
(mm) Ø20~40 Ø40~50 Ø65~125<br />
Max. interval(m) Below 1.0 Below 1.2 Below 1.5<br />
3. Anchor bolt supporting work<br />
Anchor bolt supporting work should be used for supporting a heavy indoor unit to ceiling.<br />
Clamp hanger supporting work is for hanging refrigerant pipe, drain pipe and cables.<br />
It can prevent vibrating noise from passing through pipe.<br />
We recommend set anchor bolt for supporting indoor unit and strong anchor bolt for supporting pipes and cables<br />
Guideline for each installation process 299
Drain piping work 5CSL0-06B<br />
2.3.2 Drain pipe trap (only for high static duct)<br />
A ≥ 50mm<br />
SP = External Pressure<br />
(mmAq)<br />
Ex) External Pressure<br />
= 10mmAq<br />
A<br />
A ≥ 50mm<br />
B ≥ 50mm<br />
<br />
Indoor unit<br />
Plug<br />
U-Trap<br />
- In case <strong>of</strong> duct high static pressure, the U trap maintains a positive pressure on the indoor side <strong>of</strong> the unit.<br />
Models with drain pump:<br />
Models without drain pump<br />
Max. 700<br />
Polyethylene insulation 10t<br />
PVC drain pipe<br />
300mm or less<br />
PVC elbow<br />
Drain pump<br />
PVC<br />
Flexible hose<br />
[Unit : mm]<br />
Metal clamp<br />
Flexible drain hose<br />
Drain pan Thermal insulation(bend area)<br />
300 Guideline for each installation process<br />
B<br />
Common drain pipe<br />
Thermal insulation (drain pipe area)
5CSL0-06B<br />
2.3.3 Grouped drain pipes<br />
NOTE<br />
It is standard work practice to make connections to the main pipe from above.<br />
The pipe down from the combination should be as large as possible.<br />
The diameter <strong>of</strong> ventilation pipe should be same or larger than drain pipe diameter.<br />
45~60°<br />
45~60°<br />
45~60°<br />
Grouped drain piping standard<br />
slope 1/50 ~ 1/100<br />
45~60° angle connection against overflow<br />
Sharing horizontal pipe<br />
700mm<br />
maxinmum<br />
Common drain pipe<br />
Trap in the end<br />
Drain piping work<br />
Face the vent pipe mouth<br />
downward to keep foreign matter<br />
from penentrating the system<br />
1. Trap is required if the pie is open towards sewage to prevent bad smell from coming to indoor.<br />
2. Do not connect drain pipe with building common drain pipe in heavy snow area. It might block the pipe with ice and<br />
remaining collected water can get back to indoor unit.<br />
Provide seperate air conditioner drain pipe.<br />
- For drain pipe diameter selection, refer to the following table.<br />
- The drainpipe should be used for only air conditioners. If you share it for rainwater drain, you should be careful <strong>of</strong> a<br />
back flow, leakage, bad odor and so on.<br />
- Use separate drain pipe for polluted water or wasted water<br />
NOTE<br />
Sum <strong>of</strong> the capacity<br />
<strong>of</strong> indoor units (Btu/h)<br />
[Table] Drain pipe diameter selection standard<br />
~80,000 ~200,000 ~400,000 ~600,000 ~1000,000<br />
Internal diameter (External) 25(32) 32(40) 40(50) 50(60) 65(75)<br />
Select the diameter <strong>of</strong> the horizontal pipe bigger than vertical.<br />
Guideline for each installation process 301
Drain piping work 5CSL0-06B<br />
2.3.4 Caution for drain piping work<br />
Notice on drain working<br />
1. Drain pipe should be insulated all connected joints and ends.<br />
CAUTION<br />
Flexible tube should be connected with clamp concentrically.<br />
If not, water will leak from the connection.<br />
<br />
2. No reverse slope for drain connection<br />
Water flow<br />
<br />
Sh Sharp crook<br />
Sharp crook<br />
302 Guideline for each installation process
5CSL0-06B<br />
Drain pipe insulation<br />
- Drain pipe should be insulated all connected joints and ends.<br />
Insulation<br />
not required<br />
- Do not use the loose fitting insulation.<br />
Drain water leakage test<br />
- Water leakage test should be performed 24 hours later after drain work finishing.<br />
- In the test, only water should be used. Other liquids are unacceptable.<br />
2.3.5. Outdoor unit drain (recommendation)<br />
• Mild heating region : 2) South EU<br />
use drain hose recommended (drain hole diameter 20mm)<br />
• Intermediate heating : 1) central,3) central-east,5) east EU<br />
outdoor unit Drain pan(local) recommended.<br />
• Hard heating region : 4) North EU<br />
super extreme heat pump model<br />
Heating<br />
Index<br />
115<br />
100<br />
85<br />
Insulation<br />
required<br />
1) Central<br />
Loose fitting<br />
wrong insulation<br />
4) North<br />
3) Central-East<br />
2) South<br />
5) East<br />
Fitting insulation<br />
Drain piping work<br />
Region devided<br />
Heating index<br />
Guideline for each installation process 303
Insulation work 5CSL0-06B<br />
2.4 Insulation work<br />
2.4.1 Insulation<br />
1) Operational steps<br />
1 EPDM length should be more<br />
longer than pipe length.<br />
Do not extend EPDM by force.<br />
2) Bending vertical side <strong>of</strong> insulation<br />
1 Use the original uncut insulation<br />
material.<br />
2 Put the pipe in EPDM insulation 3 Bond on both side <strong>of</strong> cut surfaces 4 Dry it until it becomes thick, sticky<br />
carefully so that the pipe will not <strong>of</strong> move sure to use the correct type and does not get detached.<br />
get damaged with EPDM.<br />
<strong>of</strong> bond for EPDM cut surface<br />
attaching.<br />
2 Only in specialcase is the vertical 3 Bond both sides <strong>of</strong> the surface <strong>of</strong> 4 Dry it until it becomes thick and<br />
cutting <strong>of</strong> the insulation allowed. EPDM and press them together for<br />
long lasting bonding.<br />
sticky.<br />
3) ' L'<br />
Fitting connection part insulation<br />
1 All <strong>of</strong> the fitting connecting parts 2 Make fitting cover to fit the EPDM 3 Bond the both cutting sides <strong>of</strong><br />
should be insulated.<br />
insulation fitting cover should be fitting cover.<br />
Bring face to face the each end <strong>of</strong> overlapped with insulation min 1<br />
EPDM on fitting connection part. inch (2.5cm).<br />
304 Guideline for each installation process
5CSL0-06B<br />
2.4.2 Forming the piping<br />
Insulation work<br />
1) Form the piping by wrapping the connecting portion <strong>of</strong> the indoor unit with insulation material and secure<br />
it with two kinds <strong>of</strong> vinyl tape.<br />
• If you want to connect an additional drain hose, the end <strong>of</strong> the drain outlet should be routed above the ground. Secure the<br />
drain hose appropriately.<br />
2) In cases where the outdoor unit is installed below the indoor unit perform the following.<br />
① Tape the piping, drain hose and transmission cable from down to up.<br />
② Secure the tapped piping along the exterior wall using saddle or equivalent.<br />
The cable is required to prevent rain water<br />
from entering into electrical parts <strong>of</strong> outdoor unit.<br />
4 way pipe direction : select what you want<br />
to form pipe.<br />
Guideline for each installation process 305
Insulation work 5CSL0-06B<br />
2.4.3 Essential points <strong>of</strong> thermal insulation<br />
1) Thermal insulation <strong>of</strong> refrigerant piping<br />
Be sure to give insulation work to refrigerant piping by covering liquid pipe and gas pipe separately with enough thickness<br />
heat-resistant insulation materials, so that no gap is observed in the joint between indoor unit and insulating material, and<br />
insulating materials themselves. When insulation work is insufficient, there is a possibility <strong>of</strong> condensation drip, etc. pay special<br />
attention to insulation work to ceiling <strong>pl</strong>enum.<br />
Wrong<br />
method<br />
Correct<br />
method<br />
3) Insulation tube thickness<br />
① Thickness decision <strong>of</strong> insulation tube<br />
• Insulation material: EPDM or polyethylene foam<br />
• Thermal conductivity 0.035 kcal~0.040kcal/mh°C<br />
• Heat resistance=85°C(Cooling only) or more<br />
100°C(Heat pump) or over<br />
② The thickness <strong>of</strong> the thermal insulation material must be determined in the light <strong>of</strong> the pipe sizes.<br />
Pipe size Thickness <strong>of</strong> insulation material<br />
6.35 ~ 25.4 mm 10mm or more<br />
25.4 ~ 15mm<br />
③ It will be necessary to increase the thickness <strong>of</strong> insulation in the above table when conditions are hot and humid.<br />
④ Where a customer sup<strong>pl</strong>ies his own specifications then these must be adhered to.<br />
CAUTION<br />
• Do not insulate gas or low pressure pipe and liquid or high<br />
pressure pipe together .<br />
A<br />
B<br />
C<br />
C<br />
B<br />
C<br />
A<br />
A Liquid pipe<br />
B Gas pipe<br />
C Insulation<br />
A Liquid pipe<br />
B Gas pipe<br />
C Insulation<br />
• Be sure to fully insulate connecting portion.<br />
A These parts are not insulated.<br />
2) Caution during insulation work<br />
• In case the cables are installed in the conduit, a finishing tape is not required.<br />
• Defect and insufficient insulation can cause condensation drops.<br />
• Binding the insulation too tight may result in dew drops.<br />
• Be sure not to tie rap the insulation but put special taping or the clamp at the connecting portion.<br />
• The insulation overlapping part at the piping connection must be a distance from the flaring part at the pipe connection.<br />
Outdoor temperature and hummidity around the cooling piping might exceed 30°C and RH80%, reinforce the insulation<br />
on the cooling piping (at least 20mm thick)<br />
306 Guideline for each installation process<br />
A
5CSL0-06B Electrical work<br />
2.5 Electrical work<br />
2.5.1 Precautions<br />
CAUTION<br />
When knocking out knock holes<br />
• To punch a knock hole, hit on it with a hammer.<br />
• After knocking out the holes, we recommend you paint<br />
the edges and areas around the edges using paint to<br />
prevent rusting.<br />
• When passing electrical wiring through the knock holes,<br />
remove any burrs from the knock holes and wrap the<br />
wiring with protective tape to prevent damage.<br />
Use a conduit for the cable<br />
• Outside the unit, make sure the thin signal cable (i.e. for the<br />
remote control, between units, etc.) and the thick electric<br />
wiring do not pass near each other and use <strong>of</strong> the shield signal<br />
cable is recommended.<br />
Otherwise, the outdoor unit may be affected by electrical<br />
noise (external noise), and malfunction or fail.<br />
• Secure the wiring with the accessory clamps so that it does<br />
not touch the piping.<br />
• Make sure the wiring and the electric parts box cover do not<br />
stick up above the structure, and close the cover firmly.<br />
CAUTION<br />
Burr<br />
If there are any possibilities that<br />
small animals or insects enter the<br />
system through the knock holes,<br />
<strong>pl</strong>ug the holes with packing<br />
materials (to be prepared onsite).<br />
Do not operate the air conditioner until the refrigerant piping<br />
work is com<strong>pl</strong>eted.<br />
(Operating the air conditioner before the refrigerant piping<br />
work is com<strong>pl</strong>eted may damage the compressor.)<br />
• Install an earth leakage circuit breaker.<br />
Since this is a inverter air conditioner. In order to prevent<br />
malfunction <strong>of</strong> the earth leakage breaker itself, use a<br />
breaker resistant to higher harmonics.<br />
• After finishing the electric work, confirm that each electric<br />
part and terminal inside the electric parts box is connected<br />
securely.<br />
NOTE<br />
• Only pr<strong>of</strong>essional electricians having sufficient knowledge<br />
should perform the electrical wiring work.<br />
Perform the electrical wiring work in accordance with the<br />
electrical wiring diagram.<br />
Make sure to set OFF the branch switch and over current<br />
breaker before starting the work.<br />
• Install an earth leakage breaker.<br />
• Perform grounding to the indoor units and outdoor units.<br />
• Do not connect the ground wire to gas pipes, sewage<br />
pipes, lightning rods telephone ground wires.<br />
• Gas pipes ···· Can ex<strong>pl</strong>ode or catch fire if gas leaks.<br />
• Sewage pipes···· Provides no grounding effect if hard<br />
<strong>pl</strong>astic pipes are used.<br />
• Telephone ground wires and lightening rods ···· dangerous<br />
when struck by lightening due to abnormal rise in the<br />
ele trical potential in the ground.<br />
• Use only copper wires.<br />
• Make sure to shut down the power before starting the electric<br />
wiring work.<br />
Do not set ON any switch until the work is com<strong>pl</strong>eted.<br />
• The outdoor unit has an inverter compresser which generates<br />
noise and charges the outer casing with the leakag<br />
current. The outdoor unit should be grounded so that the<br />
effect <strong>of</strong> the generated noise on othe equipment can be<br />
reduced, and that the outer casing can be discharged.<br />
• Never install a phase advancing capacitor for power factor<br />
improvement.<br />
(Even if it is installed, the power factor is not improved. And<br />
if it is installed, the outdoor unit is abnormally overheated.)<br />
• Use specified electric wires in the wiring, and connect them<br />
securely.<br />
Fix them in such a way that external force is not ap<strong>pl</strong>ied at<br />
the terminals<br />
(transmission wiring in the local field and ground terminal).<br />
• Never push excessive electric wires into the units.<br />
• Protect electric wires with conduit tubes or other proper<br />
tubes so that they will not be damaged by edges <strong>of</strong> knock<br />
holes.<br />
• Do not use multi conductor cable which have more than 5<br />
wires in one core.<br />
Guideline for each installation process 307
Electrical work 5CSL0-06B<br />
2.5.2 Control wiring / power sup<strong>pl</strong>y<br />
1) All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
2) Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the<br />
current as required by the air conditioner.<br />
3) Feed the power source to the unit via a distribution<br />
switch board designed for this purpose.<br />
4) The terminal screws inside the control box may be loose<br />
due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can<br />
overload and damage electrical components.)<br />
5) Always ground the air conditioner with a grounding wire<br />
and connector to meet the LOCAL REGULATION.<br />
DC inverter Single A<br />
1Phase model<br />
Terminals on the indoor unit<br />
Terminals on the outdoor unit 1(L) 2(N) 1(L) 2(N) 3<br />
DC inverter Single A synchro<br />
Non inverter Single A<br />
1Phase heat pump model<br />
Terminals on the indoor unit<br />
Terminals on the outdoor unit 1(L) 2(N) 1(L) 2(N) 3<br />
POWER<br />
INPUT<br />
3Phase heat pump model.<br />
R S T N<br />
Power<br />
Input<br />
POWER<br />
INPUT<br />
Circuit breaker<br />
Circuit Break<br />
Power<br />
Input<br />
Terminal Block<br />
(Outdoor Unit)<br />
1(L) 2(N) 3<br />
1(L) 2(N) 3<br />
Terminal Block<br />
(Outdoor Unit)<br />
4 5<br />
1(L) 2(N) 3 4 5<br />
Terminal Block<br />
(Indoor Unit)<br />
1(L) 2(N) 3 4 5<br />
4 5<br />
308 Guideline for each installation process
5CSL0-06B<br />
Connecting the cable to Outdoor Unit<br />
Electrical work<br />
• Remove the side panel for wiring connection.<br />
• Use the cord clamp to fix the cord.<br />
• Earthing work<br />
- Case 1 :Terminal block <strong>of</strong> Outdoor Unit have mark.<br />
• Connect the cable <strong>of</strong> diameter 1.6mm2 or more to the earthing terminal provided in the control box and do earthing.<br />
- Case 2 :Terminal block <strong>of</strong> Outdoor Unit don't have mark.<br />
• Connect the cable <strong>of</strong> diameter 1.6mm2 or more, to the panel <strong>of</strong> control box, marked as and fasten with earth screw.<br />
❈ Please check !!<br />
CAUTION<br />
Connecting cable terminal<br />
Power cord terminal<br />
Cord clamp<br />
Cord clamp<br />
* Make sure the rubber bushes are<br />
Properly used in knock-out holes after<br />
connecting main Power cable<br />
• The circuit diagram is not subject to change without notice.<br />
• Be sure to connect wires according to the wiring diagram.<br />
• Connect the wires firmly, so that not to be pulled out easily.<br />
• Connect the wires according to color codes by referring the wiring diagram.<br />
Guideline for each installation process 309
Air tight test 5CSL0-06B<br />
2.6 Air tight test<br />
2.6.1 Air purging<br />
Air and moisture remaining in the refrigerant system have<br />
undesirable effects as indicated below.<br />
① Pressure in the system rises.<br />
② Operating current rises.<br />
③ Cooling (or heating) efficiency drops.<br />
④ Moisture in the refrigerant circuit may freeze and block<br />
capillary tubing.<br />
⑤ Water may lead to corrosion <strong>of</strong> parts in the refrigeration<br />
system. Therefore, the indoor/outdoor unit and connecting<br />
tube must be checked for leak tight, and vacuumed<br />
to remove incondensable gas and moisture in the system.<br />
Checking method<br />
1) Preparation<br />
• Check that each pipe (both liquid and gas side pipes)<br />
between the indoor and outdoor units have been properly<br />
connected and all wiring for the test run has been com<strong>pl</strong>eted.<br />
Remove the service valve caps from both the gas<br />
and the liquid side on the outdoor unit. Check that both the<br />
liquid and the gas side service valves on the outdoor unit<br />
are kept closed at this stage.<br />
2) Leakage test<br />
• Connect the manifold valve (with pressure gauges) and<br />
dry nitrogen gas cylinder to this service port with charge<br />
hoses.<br />
CAUTION<br />
Be sure to use a manifold valve for leakage test. If it is<br />
not available, use a stop valve for this purpose. The "Hi"<br />
knob <strong>of</strong> the manifold valve must always be kept close.<br />
Outdoor unit<br />
Gas Pipe pipe Pipe<br />
Liquid Pipe<br />
pipe<br />
Manifold gauge hose<br />
Manifold valve<br />
Pressure<br />
gauge<br />
Charge hose<br />
Nitrogen gas<br />
cylinder(in vertical<br />
standing position)<br />
Lo Hi<br />
CAUTION<br />
To avoid nitrogen entering the refrigerant system<br />
in a liquid state, the top <strong>of</strong> the cylinder must be higher<br />
than its bottom when you pressurize the system. Usually,<br />
the cylinder is used in a vertical standing position.<br />
1. Do a leakage test <strong>of</strong> all joints <strong>of</strong> the Tubing (both<br />
indoor and outdoor) and both gas and liquid side service<br />
valves. Bubbles indicate a leak. Be sure to wipe<br />
<strong>of</strong>f the soap with a clean cloth.<br />
2. After the system is found to be free <strong>of</strong> leaks, relieve the<br />
nitrogen pressure by loosening the charge hose connector<br />
at the nitrogen cylinder. When the system pressure<br />
is reduced to normal, disconnect the hose from<br />
the cylinder.<br />
2.6.2 Essential points <strong>of</strong> testing<br />
The key to successful testing is strict adherence to<br />
the following procedure:<br />
a) The liquid and gas piping in each refrigerant system<br />
should be pressurized in turn in accordance with the<br />
following steps. (Nitrogen gas must be Manifold used.) gauge<br />
Step 1: increase pressure to 0.3MPa<br />
for 3 minutes or more<br />
Step 1: increase pressure to 1.5MPa<br />
for 3 minutes or more<br />
Step 3: increase pressure to 3.8MPa<br />
for approxmate 24 hours<br />
Liquid Pipe<br />
Indicates existence<br />
<strong>of</strong> major leaks<br />
Indicates existence<br />
<strong>of</strong> major leaks<br />
310 Guideline for each installation process<br />
Gas Pipe<br />
Increasing the system pressure to 3.8MPa does not guarantee<br />
the identification <strong>of</strong> minor leaks if pressure is maintained<br />
for only a short time. It is therefore recommended<br />
that the system remain pressurized in accordance with<br />
Step 3 above for at least 24 hours.<br />
NOTE<br />
Piping should not be pressured more than 3.8MPa.<br />
b) Check for pressure drop<br />
If there is no drop in pressure then the test is deemed a<br />
success.<br />
If the pressure drops then the leak must be located. See<br />
following <strong>page</strong>.<br />
However, if there is a change in the ambient temperature<br />
between the pressurizing stage and the time when<br />
you check for a drop in pressure then you will have to<br />
adjust your calculations accordingly since a change <strong>of</strong><br />
1°C can account for a pressure change <strong>of</strong> approximately<br />
0.01MPa.<br />
Compensating adjustment value:<br />
(temperature at time <strong>of</strong> pressurizing – temperature at<br />
time <strong>of</strong> checking) × 0.01
5CSL0-06B<br />
Exam<strong>pl</strong>e:<br />
During <strong>of</strong> pressurizing: 3.8MPa 25˚C<br />
24 hours later: 3.75MPa 20˚C<br />
Although the gauge pressure is dropped from 3.8MPa to<br />
3.75MPa, it can be safely assumed that there is no leakage<br />
because the gauge pressure can also drop due to<br />
the change in outdoor temperature.<br />
(MPa)<br />
3.8<br />
3.5<br />
3.0<br />
2.5<br />
2.0<br />
1.5<br />
1.0<br />
0.5<br />
0<br />
3 minutes<br />
5 minutes<br />
Step 3 3.8MPa x 24min<br />
Step 1 1.5MPa x 5min<br />
Step 1 0.3MPa x 3min<br />
Gas Pipe<br />
Outdoor Outdoor Outdoor temperature(℃)<br />
temperature(<br />
temperature(°C)<br />
24 hours<br />
Liquid Pipe<br />
2.6.3 Checking for leakage<br />
[Check 1] (Where pressure falls while carrying out Steps 1<br />
to 3 described on previous <strong>page</strong>)<br />
▶ Check by measure gage......gas detector.<br />
▶ Check by ear......Listen for the sound <strong>of</strong> a major leakage.<br />
▶ Check by hand......Check for leak by feeling around jointed<br />
sections with hand.<br />
▶ Bubble check ......Bubbles will reveal the presence <strong>of</strong> a<br />
leakage.<br />
[Check 2] (When searching for a minor leak or when there<br />
has been a fall in pressure while the system has<br />
been fully pressurized but the source <strong>of</strong> the leak<br />
cannot be traced.)<br />
1. Release the nitrogen until the pressure reaches 0.3MPa.<br />
2. Increase pressure to 1.5MPa using gaseous<br />
refrigerant(R410).<br />
3. Search for the source <strong>of</strong> the leakage using a leackage<br />
detector such as a halide torch or a propane or electrronic<br />
detector.<br />
4. If the source <strong>of</strong> the leakage still cannot be traced then<br />
repressurize with nitrogen up to 3.8MPa and check again.<br />
(The pressure must not be increased to more than<br />
3.8MPa.)<br />
3.75<br />
25°C<br />
20°C<br />
15°C<br />
(Time)<br />
(System sam<strong>pl</strong>e)<br />
(R410A gas)<br />
Nitrogen gas Gauge Vacuum pump<br />
Do not open the<br />
service valve during<br />
the airtight test.<br />
Air tight test<br />
Important points<br />
1. Where the lengths <strong>of</strong> piping involved are particularly long<br />
then the air tight test should be carried out block by block.<br />
1) Indoor side<br />
2) Indoor side + vertical pipes<br />
3) Indoor side + vertical pipes + outdoor side<br />
CAUTION<br />
2-way valve<br />
(Open)<br />
3-way valve<br />
(Close)<br />
Liquid side<br />
Hexagonal wrench<br />
Liquid Pipe<br />
Manifold gauge<br />
Gas side<br />
Guideline for each installation process 311<br />
Gas Pipe<br />
Soap water method<br />
1. Remove the caps from the 2-way and 3-way valves.<br />
2. Remove the service-port cap from the 3-way valve.<br />
3. To open the 2-way valve turn the valve stem counterclockwise<br />
approximately 90°, wait for about 2~3 sec,<br />
and close it.<br />
4. Ap<strong>pl</strong>y a soap water or a liquid neutral detergent on the<br />
indoor unit connection or outdoor unit connections by a<br />
s<strong>of</strong>t brush to check for leakage <strong>of</strong> the connecting points<br />
<strong>of</strong> the piping.<br />
5. If bubbles appear then those points have leakage.<br />
Cap
Vacuum drying works<br />
2.7 Vacuum drying works<br />
2.7.1 What is Vacuum drying?<br />
Vacuum drying is : The use <strong>of</strong> a vacuum pump to<br />
vaporize(gasify) the moisture (liquid) inside the pipe and<br />
expel it leaving the pipes com<strong>pl</strong>etely dry inside.<br />
At 1 atm(760mmHg) the boiling point (evaporating temperature)<br />
<strong>of</strong> water is 100°C but if a vacuum is created inside the<br />
pipes using a vacuum pump then the boiling point is rapidly<br />
reduced as the degree <strong>of</strong> the vacuum is increased.<br />
If the boiling point is reduced to a level below that <strong>of</strong> the<br />
ambient temperature then the moisture in the pipes will<br />
evaporate.<br />
Exam<strong>pl</strong>e<br />
When outside temperature is 11.7°C as shown in the table<br />
on the right , the degree <strong>of</strong> vacuum must be lowered below -<br />
750mmHg<br />
Boilng point <strong>of</strong><br />
water(°C)<br />
The degree<br />
<strong>of</strong> a vacuum<br />
mmHg<br />
Pressure<br />
Pa Torr<br />
40 -705 7333 55<br />
30 -724 4800 36<br />
26.7 -735 3333 25<br />
24.4 -738 3066 22<br />
22.2 -740 2666 20<br />
20.6 -742 2400 18<br />
17.8 -745 2000 15<br />
15.0 -747 1733 13<br />
11.7 -750 1333 10<br />
7.2 -752 1066 8<br />
0 -755 667 5<br />
The evacuation <strong>of</strong> air conditioner piping provides the following<br />
effects.<br />
1. Vaccum drying<br />
2. Removes air and nitrogen(used in air-tightness test)<br />
from the inside <strong>of</strong> pipes.<br />
Therefore , it is necessary to ensure that both purposes<br />
have been achieved in the vacuum drying operation.<br />
NOTE<br />
Key point: Maintain a vacuum level <strong>of</strong> -755mmHg<br />
mmHg<br />
760<br />
-20 -10 0 10 20 30 40<br />
(C)<br />
50 60 70<br />
2.7.2 Evacuation<br />
Temperature<br />
5CSL0-06B<br />
1. Connect the manifold hose end described in the preceding<br />
steps to the vacuum pump to evacuate the tubing and<br />
indoor unit. Confirm the "Lo" knob <strong>of</strong> the manifold valve is<br />
open. Then, run the vacuum pump. The operation time<br />
for evacuation varies with tubing length and capacity <strong>of</strong><br />
the pump. The following table shows the time required for<br />
evacuation.<br />
2. When the desired vacuum is reached, close the "Lo"<br />
knob <strong>of</strong> the manifold valve and stop the vacuum pump.<br />
312 Guideline for each installation process<br />
3.8MPa<br />
Required degree<br />
<strong>of</strong> vaccum<br />
Evaporation<br />
point<br />
The degree <strong>of</strong> a vacuum (mmHg)<br />
60<br />
160<br />
260<br />
0<br />
360<br />
460<br />
560<br />
660<br />
670<br />
680<br />
690<br />
700<br />
710<br />
720<br />
730<br />
740<br />
755<br />
760mmHg<br />
700<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
90<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
5<br />
Absolute pressure (mmHg)<br />
0 mmHg<br />
x<br />
Outside<br />
temperature<br />
range
5CSL0-06B Vacuum drying works<br />
CAUTION<br />
Outdoor unit<br />
Pressure<br />
gauge<br />
Gas Pipe<br />
Manifold valve<br />
Lo Hi<br />
Open Close<br />
Vacuum pump<br />
(0.5 ~ 1HP)<br />
Liquid Pipe Pipe<br />
Manifold gauge<br />
Finishing the job<br />
1. With a service valve wrench, turn the valve stem <strong>of</strong> liquid<br />
side valve counter-clockwise to fully open the valve.<br />
2. Turn the valve stem <strong>of</strong> gas side valve counter-clockwise<br />
to fully open the valve.<br />
3. Loose the charge hose connected to the gas side service<br />
port slightly to release the pressure, then remove<br />
the hose.<br />
4. Re<strong>pl</strong>ace the flare nut and fasten the flare nut securely<br />
with an adjustable wrench. This process is very important<br />
to prevent leakage from the system.<br />
5. Re<strong>pl</strong>ace the valve caps at both gas and liquid side service<br />
valves and fasten them tight. This com<strong>pl</strong>etes air<br />
purging with a vacuum pump. The air conditioner is now<br />
ready for test run.<br />
2.7.3 Choosing a vacuum pump<br />
The necessity for counter flow prevention<br />
After the vacuum process <strong>of</strong> the refrigerant cycle, the inside<br />
<strong>of</strong> the hose will be vacuumed after stopping the vacuum<br />
pump, the oil <strong>of</strong> vacuumpump may flow back. Moreover, if<br />
the vacuum pump stops during the operation for some rea-<br />
Guideline for each installation process 313<br />
son.<br />
Gas Pipe<br />
Manifold gauge<br />
Therefore, in order to prevent the counter flow from the vacuum<br />
pump, a check valve is reguired.<br />
1) Vacuum pump performanceLiquid<br />
Pipe<br />
The 2 most important things for determining vacuum<br />
pump performance are as follows:<br />
(1) Exhaust velocity<br />
(2) Degree <strong>of</strong> vacuum<br />
(1) Exhaust velocity<br />
Exhaust volume is usually expressed as l/min or m3 /hr. The<br />
larger the number, the faster the vacuum is achieved.<br />
Generally speaking, the faster the exhaust velocity, the larger<br />
and heavier the vacuum pump itself is.<br />
Commercially available vacuum pumps (exhaust velocity <strong>of</strong><br />
20 - 30 l/min) usually take an extremely long time to achieve<br />
vacuum. (We recommend a vacuum pump <strong>of</strong> approx. 60 -<br />
100 l/min.)<br />
(2) Degree <strong>of</strong> vacuum<br />
Ultimate vacuum varies largely according to use <strong>of</strong> the vacuum<br />
pump. Vacuum pumps used for vacuum forming cannot<br />
be used for vacuum drying. (A vacuum pump with a high<br />
degree <strong>of</strong> vacuum is required.)<br />
When selecting a vacuum, you should select one which is<br />
capable <strong>of</strong> achieving 0.2 Torr <strong>of</strong> ultimate vacuum.<br />
Degree <strong>of</strong> vacuum is expressed in Torr, micron, mmHg, and<br />
Pascal (Pa). The units correlate as follows:<br />
Unit<br />
Standard<br />
atmospheric<br />
pressure<br />
Perfect vacuum<br />
Gauge Pressure kg/cm 2 0 -1.033<br />
Absolute Pressure kg/cm 2 abs 1.033 0<br />
Torr Torr 760 0<br />
Micron Micron 760000 0<br />
mmHg mmHg 0 760<br />
Pa Pa 1013.33 0
Vacuum drying works<br />
Degree <strong>of</strong> vacuum must be within the range expressed by<br />
0 Torr<br />
0 Pa<br />
760 mmHg<br />
Perfect vacuum<br />
5 Torr<br />
667 Pa<br />
755 cmHg<br />
Vacuum target value<br />
2) Vacuum pump maintenance<br />
Because <strong>of</strong> their nature, most vacuum pumps contain large<br />
amounts <strong>of</strong> oil which lubricates bearings, etc., and functions<br />
to enhance airtightness <strong>of</strong> pistons. When using a vacuum<br />
pump to discharge air from refrigerant piping, moisture in<br />
the air tends to get mixed in with the oil. You must therefore<br />
change oil periodically and make sure the proper oil level is<br />
maintained. (Perform periodic inspections in accordance<br />
with the operating instructions.)<br />
3) Degree <strong>of</strong> vacuum measurement<br />
An extremely accurate vacuum gauge is required to test<br />
degree <strong>of</strong> vacuum. You cannot accurately measure degree<br />
<strong>of</strong> vacuum with the compound gauge on the gauge manifold.<br />
A Pirani vacuum gauge is required to measure degree<br />
<strong>of</strong> vacuum accurately. Because Pirani gauges are very sensitive<br />
and require extreme care when using, they are not<br />
very suitable for use in the field. You should therefore use<br />
the Pirani gauge to calibrate the attached vacuum gauge on<br />
the gauge manifold and the degree <strong>of</strong> vacuum <strong>of</strong> the vacuum<br />
pump.<br />
4) Calibration method<br />
1. Connect a Pirani vacuum gauge and the gauge manifold<br />
vacuum gauge (760 mmHg) to the vacuum pump at the<br />
same time, and run the pump for about 3 minutes.<br />
2. Make sure the reading <strong>of</strong> the Pirani vacuum gauge is 5<br />
Torr (667 Pa ) or less. The reading <strong>of</strong> conventional vacuum<br />
pumps lowers to about 0.2 Torr.<br />
If the reading is not 5 Torr or less, check the vacuum<br />
pump oil. (Oil is low in many cases.)<br />
3. Check the attached gauge on the gauge manifold. Adjust<br />
the gauge if the reading is not exactly correct.<br />
4. Adjust the gauge manifold valve so that the Pirani vacuum<br />
gauge reads 5 Torr.<br />
5. Mark the position indicated by the gauge manifold gauge<br />
with an oil based ink pen.<br />
6. Use the mark <strong>of</strong> the gauge manifold as a target when<br />
vacuuming in the field.<br />
Pressure detection section<br />
Indicator<br />
5CSL0-06B<br />
760 Torr<br />
1013.33 hPa<br />
0 mmHg<br />
Standard atmospheric pressure<br />
Gauge manifold<br />
(Reference) Types <strong>of</strong> vacuum pump with respect to maximum<br />
degree <strong>of</strong> vacuum<br />
Vacuum pump<br />
Many handy<br />
pumps fall into this<br />
category<br />
314 Guideline for each installation process<br />
Type<br />
Oil rotary<br />
(Oil using)<br />
Oilless rotary<br />
(No need <strong>of</strong> oil)<br />
Maximum degree <strong>of</strong> vacuum Use<br />
Expulsion capacity Vacuum drying Air expulsion<br />
0.02 mmHg<br />
100 l/min Suitable Suitable<br />
10 mmHg<br />
0.02 mmHg<br />
50 l/min<br />
40 l/min<br />
Unsuitable<br />
Suitable<br />
Suitable<br />
Suitable
5CSL0-06B<br />
2.7.4 Vacuum drying procedure<br />
There are two vacuum drying methods and the appropriate one<br />
should always be chosen to confirm with individual local conditions.<br />
[Normal vacuum drying]........The standard method<br />
[Operational steps]<br />
1. Vacuum drying (1st time): Connect a manifold gauge to the service<br />
port <strong>of</strong> the liquid or gas pipe and operate the vacuum pump<br />
for at least 2 hours.<br />
(The degree <strong>of</strong> vacuum produced should be in excess <strong>of</strong> 5 Torr)<br />
If after 2 hours the vacuum produced has not exceeded 5 Torr<br />
then either there is moisture in the pipe or there is a leak.<br />
Operate the vacuum pump for further one more hour.<br />
If, even after 3 hours, the vacuum has not reached 5 Torr then<br />
check the system for a leak.<br />
2. Carry out vacuum test.<br />
Produce a vacuum in excess <strong>of</strong> 5 Torr and do not release it for<br />
an hour or more. Check the vacuum gauge to make sure that it<br />
has not risen. (If the gauge rise then there is still moisture in the<br />
pipe or there is a leak somewhere.)<br />
3. Additional charge <strong>of</strong> refrigerant.<br />
Connect the charging cylinder to the liquid pipe service port and<br />
charge with the required amount <strong>of</strong> refrigerant.<br />
4. Open stop valve to the full.<br />
Open the stop valve on the liquid and the gas pipes to the full.<br />
NOTE<br />
Vacuums should be produced in both the liquid and the gas pipes.<br />
(Because there are a large number <strong>of</strong> functional components in the<br />
indoor unit which cut <strong>of</strong>f the vacuum mid-way through)<br />
Rising pressure<br />
Falling<br />
pressure<br />
(vacuum)<br />
+0.05MPa<br />
(Atmospheric<br />
pressure)<br />
0 MPa<br />
Vacuum<br />
drying<br />
Vacuum drying works<br />
Maintaining<br />
vacuum test<br />
(2 hours) (1 hours)<br />
Time required: approximately 3 hours.<br />
Guideline for each installation process 315<br />
0 MPa<br />
-200 mmHg<br />
-400 mmHg<br />
-600 mmHg<br />
-700 mmHg<br />
-760 mmHg<br />
-755 mmHg<br />
(5 Torr)<br />
Time.<br />
Additional refrigerant<br />
charge
Additional charge <strong>of</strong> refrigerant 5CSL0-06B<br />
2.8 Additional charge <strong>of</strong><br />
refrigerant<br />
2.8.1 Refrigerant charging instructions<br />
Refrigerant charging<br />
1. The results <strong>of</strong> all calculations must be recorded. (make a<br />
list)<br />
2. The refrigerant will need to be additionally charged when<br />
the distance between the outdoor Unit and the most distant<br />
indoor unit is more than length (refer to section 8 outdoor<br />
unit installation condition)<br />
3. The additional charging operation should be carried out<br />
by input <strong>of</strong> liquid into the liquid pipes from a charging<br />
cylinder following com<strong>pl</strong>etion <strong>of</strong> the Vacuum drying operation.<br />
4. When the additional charging operation cannot be satisfactorily<br />
com<strong>pl</strong>eted , use the action <strong>of</strong> the compressor to<br />
com<strong>pl</strong>ete the additional charging during the test run.<br />
R-410A is a non-azeotrope refrigerants. Therefore , these<br />
refrigerants must be charged in the Liquid state.<br />
When charging the refrigerant into equipment from the cylinder<br />
, turn the refrigerant cylinder upside down.<br />
NOTE<br />
Make sure that the refrigerant (liquid) is taken out from the<br />
bottom part <strong>of</strong> the refrigerant cylinder.<br />
Do not take out the refrigerant (gas) at the upper <strong>of</strong> the<br />
refrigerant cylinder for charging.<br />
Refrigerant<br />
cylinder<br />
Outdoor unit A<br />
CAUTION<br />
Outdoor unit B<br />
• Since some refrigerant cylinders differ in the internal<br />
mechanism, it is necessary to examine the cylinder<br />
carefully.<br />
(Some cylinders have a siphon tube to eliminate the<br />
need for turning it upside down)<br />
316 Guideline for each installation process<br />
Refrigerant<br />
cylinder<br />
siphon tube
5CSL0-06B<br />
2.9 Trial test run operation<br />
2.9.1 Test run procedure<br />
Check the following before turning power on<br />
Wrong power wiring , loosed screws<br />
Wrong control transmission wiring , loose screws<br />
Piping size , presence <strong>of</strong> thermal insulation<br />
Measurement <strong>of</strong> main power circuit insulation<br />
Addition or refrigerant if required<br />
Fully open respective stop valves on liquid, gas<br />
Turn on outdoor unit power<br />
Use a mega-tester<br />
Be sure to record the additional<br />
quantity <strong>of</strong> refrigerant<br />
2.9.2 Evaluation performance<br />
Evaluation <strong>of</strong> the performance<br />
Operate unit for 15~20 minutes, then check the system<br />
refrigerant charge:<br />
1. Measure the pressure <strong>of</strong> the gas side service valve.<br />
2. Measure the temperature <strong>of</strong> the intake and discharge <strong>of</strong> air.<br />
3. Ensure the difference between the intake temperature<br />
and the discharge is more than 8°C<br />
4. For reference, the gas side pressure <strong>of</strong> optimum condition<br />
is as below. (Cooling)<br />
Refrigerant<br />
Discharge air<br />
Outside ambient<br />
Temp.<br />
Intake temperature<br />
Discharge<br />
temperature<br />
The pressure <strong>of</strong> the gas side<br />
service valve.<br />
R410A 35°C (95°F) 8.0~10.0kg/cm 2 G<br />
NOTE<br />
Trial test run operation<br />
: If the actual pressure is higher than shown, the system is<br />
most likely overcharged so extra refrigerant should be<br />
removed.<br />
If the actual pressure is lower than shown, the system is<br />
most likely undercharged so extra refrigerant should be<br />
added.<br />
The air conditioner is now ready for use.<br />
2.9.3 Transfer to customer with ex<strong>pl</strong>anation<br />
1. Operational step<br />
Com<strong>pl</strong>ete test run<br />
Ex<strong>pl</strong>ain how to<br />
operate and<br />
maintain equipment<br />
Make final report<br />
(test run<br />
inspection sheet)<br />
Hand over<br />
relevant printed<br />
materials<br />
a) The measurements taken during the test run should be<br />
recorded and kept on a test run inspection sheet.<br />
b) Do not forget to record the length <strong>of</strong> the refrigerant piping<br />
and the refrigerant additional charging volume on the<br />
<strong>pl</strong>ate on the back <strong>of</strong> the outdoor unit external notice<br />
board, as this information will be required for servicing<br />
the system.<br />
c) Ex<strong>pl</strong>ain to the customer how to operate and maintain the<br />
equipment and let him try it.<br />
d) Assemble all the relevant diagrams and other printed<br />
matter which is required to operate the system and hand<br />
over to the customer (on the spot) and request him to<br />
keep it handy.<br />
e) Service contact address.<br />
List <strong>of</strong> equipment which has been delivered<br />
Installation drawing<br />
It is essential to prepare a control wiring diagram<br />
which clarifies the refrigerant system and the<br />
control system.<br />
1 set <strong>of</strong> operation manuals<br />
Names <strong>of</strong> those responsible for the<br />
work (emergency contact address)<br />
Equipment guarantees.<br />
Guideline for each installation process 317
Safety precautions<br />
3. Installation <strong>of</strong> indoor unit<br />
3.1 Safety precautions<br />
Please strictly follow the instructions given in the Installation<br />
manual .Improper installation by ignoring the instructions<br />
can lead to damage to life and property.<br />
Make sure to read the following safety instructions very<br />
carefully and throughly .<br />
WARNING<br />
: This symbol indicates the possibility <strong>of</strong><br />
death or serious injury.<br />
CAUTION : This symbol indicates the possibility <strong>of</strong><br />
injury or damage to properties.<br />
■ The meanings <strong>of</strong> the symbols used in this manual are as<br />
shown below.<br />
: Be sure not to do.<br />
: Be sure to follow the instruction.<br />
WARNING<br />
Do not use a defective or underrated circuit breaker.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Always use this ap<strong>pl</strong>iance on a dedicated circuit breaker.<br />
• Otherwise it can cause electric shock or fire.<br />
For electrical work, contact the dealer, seller, a qualified<br />
electrician, or an authorized service center. Do not disassemble<br />
or repair the product by yourself.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Always ground the product as per the field wiring diagram.<br />
Do not connect the ground wire to gas or water pipes lightening<br />
rod or telephone ground wire.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Install the panel and the cover <strong>of</strong> control box securely.<br />
• There is risk <strong>of</strong> fire or electric shock due to dust , water etc.<br />
Use the correctly rated breaker or fuse.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Do not modify or extend the power cable. If the power<br />
cable or cord has scratches or skin peeled <strong>of</strong>f or deterioted<br />
then immediately re<strong>pl</strong>ace it.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
For installation, removal or reinstall, always contact the<br />
dealer or an Authorized Service Center.<br />
• There is risk <strong>of</strong> fire, electric shock, ex<strong>pl</strong>osion, or injury.<br />
Do not install the product on a defective installation foundation.<br />
Be sure that the installation area does not deteriorate<br />
with age.<br />
• If the base collapses, the air conditioner could fall with it,<br />
causing property damage, product failure, and personal<br />
injury.<br />
When the product is soaked (flooded or submerged) in<br />
water, contact an Authorized Service Center for repair<br />
before using it again.<br />
5CSL0-06B<br />
• There is risk <strong>of</strong> fire or eletric shock.<br />
In outdoor unit the step-up capacitor sup<strong>pl</strong>ies high voltage<br />
electlicity to the electrical components.<br />
Be sure to discharge the capacitor com<strong>pl</strong>etely before conducting<br />
the repair work.<br />
• An charged capacitor can cause electrical shock.<br />
Be sure to use only those parts which are listed in the service<br />
parts list. Never attempt to modify the equipment.<br />
• The use <strong>of</strong> inappropriate parts can cause an electrical shock,<br />
excessive heat generation or fire.<br />
Indoor/outdoor wiring connections must be secured tightly<br />
and the cable should be routed properly so that there is<br />
no force pulling the cable at the connection terminals.<br />
• Improper or loose connections can cause excessive heat<br />
generation or fire.<br />
Safely dispose <strong>of</strong>f the packing materials.<br />
• Things like screws, nails, batteries, broken things etc. after<br />
installation or svc can cause injury to small kids. Tear away<br />
and throw away the <strong>pl</strong>astic packaging bags so that children<br />
will not <strong>pl</strong>ay with them.<br />
During svc be sure to check the refrigerant to the used.<br />
• Incorrect refrigerant used can prevent the normal operation <strong>of</strong><br />
the unit.<br />
When installing the unit, use the installation kit provided<br />
with the product.<br />
• Otherwise the unit may fall and cause severe injury .<br />
Do not touch, operate, or repair the product with wet<br />
hands.<br />
• There is risk <strong>of</strong> electric shock or fire.<br />
Do not <strong>pl</strong>ace a heater or other ap<strong>pl</strong>iances near the power<br />
cable.<br />
• There is risk <strong>of</strong> fire and electric shock.<br />
Do not allow water to run into electric parts. Install the unit<br />
away from water sources<br />
• There is risk <strong>of</strong> fire, failure <strong>of</strong> the product, or electric shock.<br />
Do not store or use or even allow flammable gas or combustibles<br />
near the product.<br />
• There is risk <strong>of</strong> fire or failure <strong>of</strong> product.<br />
Do not use the product in a tightly closed space for a long<br />
time. Perform ventilation regularly.<br />
• Oxygen deficiency could occur and hence harm your health.<br />
If strange sounds, smell or smoke comes from product,<br />
immediately turn the breaker <strong>of</strong>f or disconnect the power<br />
sup<strong>pl</strong>y cable.<br />
• There is risk <strong>of</strong> electric shock or fire.<br />
When installing the unit, use the installation kit provided<br />
with the product.<br />
• Otherwise the unit may fall and cause severe injury.<br />
Do not open the front grill <strong>of</strong> the product during operation.<br />
(Do not touch the electrostatic filter, if the unit is so<br />
equipped.)<br />
• There is risk <strong>of</strong> physical injury, electric shock or product failure.<br />
318 Installation <strong>of</strong> indoor unit
5CSL0-06B Safety precautions<br />
Ventilate the product room from time to time when operating<br />
it together with a stove, or heating element etc.<br />
• Oxygen deficiency can occur and hence harm your health.<br />
Turn the main power when cleaning or repairing the product.<br />
• There is risk <strong>of</strong> electric shock.<br />
When the product is not to be used for a long time, shut<br />
<strong>of</strong>f the circuit breaker.<br />
• There is risk <strong>of</strong> product damage or failure or unintended operation.<br />
CAUTION<br />
Use two or more peo<strong>pl</strong>e to lift and transport the product.<br />
• Avoid personal injury.<br />
Do not install the product where it will be exposed to<br />
sea wind (salt spray) directly.<br />
• It may cause corrosion on the product. Corrosion, particularly<br />
on the condenser and evaporator fins, could cause<br />
product malfunction or inefficient operation.<br />
Install the drain hose to ensure that water is drained<br />
away properly.<br />
• A bad connection may cause water leakage.<br />
Keep level even when installing the product.<br />
• To avoid vibration or noise.<br />
Always check for gas (refrigerant) leakage after installation<br />
or repair <strong>of</strong> product.<br />
• Low pressure levels may cause failure <strong>of</strong> product.<br />
Do not block the inlet or outlet <strong>of</strong> air flow.<br />
• It may cause product failure.<br />
Use a s<strong>of</strong>t cloth to clean. Do not use harsh detergents,<br />
solvents or s<strong>pl</strong>ashing water etc .<br />
• There is risk <strong>of</strong> fire, electric shock, or damage to the <strong>pl</strong>astic<br />
parts <strong>of</strong> the product.<br />
Do not step on or put anyting on the product. (outdoor<br />
units)<br />
• There is risk <strong>of</strong> personal injury and failure <strong>of</strong> product.<br />
Do not insert hands or other objects through the air<br />
inlet or outlet while the product is operating.<br />
• There are sharp and moving parts that could cause personal<br />
injury.<br />
Be cautious when unpacking and installing the product.<br />
• Sharp edges could cause injury. Be especially careful <strong>of</strong><br />
the case edges and the fins on the condenser and evaporator.<br />
If the refrigerant gas leaks during the repair, do not<br />
touch the leaking refrigerant gas.<br />
• The refrigerant gas can cause frostbite (cold burn).<br />
Do not tilt the unit when removing or uninstalling it.<br />
• The condensed water inside can cause spill and wet the<br />
furniture and the floor.<br />
Do not mix air or gas other than the specified refrigerant<br />
used in the system.<br />
• If air enters the refrigerant system, an excessively high<br />
pressure results, causing equipment damage or injury.<br />
Re<strong>pl</strong>ace the all batteries in the remote control with new<br />
ones <strong>of</strong> the same type. Do not mix old and new batteries<br />
or different types <strong>of</strong> batteries.<br />
• There is risk <strong>of</strong> fire or ex<strong>pl</strong>osion.<br />
If the liquid from the batteries gets onto your skin or<br />
clothes, wash it well with clean water. Do not use the<br />
remote if the batteries have leaked.<br />
• The chemicals in batteries could cause burns or other<br />
health hazards.<br />
Do not use the product for special purposes, such as<br />
preserving foods, works <strong>of</strong> art, etc. It is a consumer air<br />
conditioner, not a precision refrigeration system.<br />
• There is risk <strong>of</strong> damage or loss <strong>of</strong> property.<br />
Do not touch the metal parts <strong>of</strong> the product when<br />
removing the air filter.<br />
• There is risk <strong>of</strong> personal injury.<br />
If the refrigerant gas leaks during the installation or<br />
operation ventilate the area immediately.<br />
• Otherwise it can be harmfull for your health.<br />
Do not turn <strong>of</strong>f the power immediately after stopping<br />
the operation.<br />
• Always wait for 5 minutes before turning <strong>of</strong>f the power otherwise<br />
water leakage and troubles can occur.<br />
Do not let the air conditioner run for a long time when<br />
the humidity is very high and a door or a window is left<br />
open.<br />
• Moisture may condense and wet or damage furniture.<br />
Do not expose your skin or kids or <strong>pl</strong>ants to the cool or<br />
hot air draft.<br />
• This could harm to your health.<br />
Do not drink the water drained from the product.<br />
• It is not sanitary and could cause serious health issues.<br />
Use a firm stool or ladder when cleaning, maintaining<br />
or repairing the product at an height.<br />
• Be careful and avoid personal injury.<br />
Dismantling <strong>of</strong> the unit , treatment <strong>of</strong> the refrigerant oil<br />
and eventual parts should be done in accordance with<br />
local and national standards.<br />
Do not recharge or disassemble the batteries. Do not<br />
dispose <strong>of</strong>f batteries in fire.<br />
• They may burn or ex<strong>pl</strong>ode.<br />
Installation <strong>of</strong> indoor unit 319
Safety precautions<br />
3.1.1 Points for ex<strong>pl</strong>anation about<br />
operations<br />
The items with WARNING and CAUTION marks in the operation<br />
manual are the items pertaining to possibillties for<br />
bodily injury and material damage in addition to the general<br />
usage <strong>of</strong> the product. Accordingly, it is necessary that you<br />
make a full ex<strong>pl</strong>anation about the described contents and<br />
also ask your customers to read the owner's manual.<br />
1. Note to the installer<br />
Be sure to instruct customers how to properly operate the<br />
unit (especially cleaning filters, operating different functions,<br />
and adjusting the temperature) by having them carry out<br />
operations themselves while looking at the manual.<br />
3.1.2 Selecting installation site for<br />
indoor units<br />
1. Select an installation site where the following conditions<br />
are fulfilled and that meets with your customer's<br />
approval.<br />
1) Location strong enough to bear the weight <strong>of</strong> the unit.<br />
2) Location accessible and having enough clearance for<br />
inspection and service in the future.<br />
3) Location allowing easy condensate drainage and suitable<br />
gradient <strong>of</strong> the unit and the drain pipe.<br />
4) Piping between the indoor and outdoor unit is possible<br />
within the allowable limits.<br />
5) Location free from electrical noise.<br />
6) Location allowing optimum air distribution without any<br />
blocking to air flow.<br />
7) Location having no risk <strong>of</strong> flammable gas leakage.<br />
8) Location free from mineral oil mist or an oil spray or<br />
vapor exam<strong>pl</strong>e in kitchen .It could result in leakage .<br />
9) Location free from corrosive gases such as sulphurous<br />
acid gas because it corrodes the copper pipes or soldered<br />
parts resulting in leakage .<br />
10) Location free from any machinery emitting electromagnetic<br />
waves which may disturb the control system<br />
thus causing malfunction <strong>of</strong> the unit .<br />
11) Location free from flammable gases , carbon fibre , or<br />
ignitable dust suspensions in the air or where volatile<br />
flames are handled like gasoline or thinner. Operating<br />
in such conditions may result in fire .<br />
12) Install the indoor and outdoor units, power sup<strong>pl</strong>y<br />
wiring and connecting wires at least 1m away from<br />
televisions or radios in order to prevent image interference<br />
or noise. (Depending on the radio waves, a<br />
distance <strong>of</strong> 1m. may not be sufficient enough to eliminate<br />
the noise.)<br />
5CSL0-06B<br />
13) Consider whether the <strong>pl</strong>ace where the unit will be<br />
installed can support the full weight <strong>of</strong> the unit, and<br />
reinforce it with boards and beams, etc. If needed<br />
before proceeding with the installation. Also, reinforce<br />
the <strong>pl</strong>ace to prevent vibration and noise before<br />
installing.<br />
14) The indoor artcool, artcool mirror, wallmount unit may<br />
not be directly installed on the wall. Use the attached<br />
installation <strong>pl</strong>ate before installing the unit.<br />
15) Obey the local and national regulations and limits<br />
regarding airconditioner installation.<br />
320 Installation <strong>of</strong> indoor unit
5CSL0-06B Safety precautions<br />
2. For the following items, take special care during construction and check after installation is finished<br />
1. Items to be checked after com<strong>pl</strong>etion <strong>of</strong> installtion work<br />
Items to be checked If not properly done, what is likely to occur Check<br />
Are the indoor and outdoor unit fixed firmly? The units may drop, vibrate or make noise.<br />
Is the gas leak test finished? It may result in insufficient cooling or heating.<br />
Is the unit fully insulated? Condensate water may drip.<br />
Does drainage flow smoothly? Condensate water may drip.<br />
Does the power sup<strong>pl</strong>y voltage correspond to that<br />
shown on the name <strong>pl</strong>ate?<br />
The unit may malfunction or the components burn out.<br />
Are wiring and piping correct? The unit may malfunction or the components burn out.<br />
Is the unit safely grounded? It may be dangerous during electric leakage.<br />
Is wiring size correct according to specifications? The unit may malfunction or the components burn out.<br />
Is there something blocking the air outlet or inlet <strong>of</strong><br />
either the indoor or outdoor units?<br />
It may result in insufficient cooling or heating.<br />
Are refrigerant piping length and additional<br />
refrigerant charge noted down?<br />
The refrigerant charge in the system is not clear.<br />
3.1.3 Before installation<br />
1. During product unpacking and removing it from the packing case, be sure to lift it without exerting any pressure on<br />
other parts, especially, horizontal flaps, the refrigerant piping, drain piping, and other resin parts.<br />
• The accessories needed for installation must be retained in your custody until the installation work is com<strong>pl</strong>eted. Do not discard<br />
them!<br />
• Decide upon a line <strong>of</strong> transport.<br />
• Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is unavoidable, use a sling <strong>of</strong><br />
s<strong>of</strong>t material or protective <strong>pl</strong>ates together with a rope when lifting, to avoid damage or scratches to the unit.<br />
• When using the wireless remote controller, refer to the installation manual attached to the wireless remote controller.<br />
NOTE<br />
• Be sure to read this manual before installing the indoor unit.<br />
• Entrust installation to the <strong>pl</strong>ace <strong>of</strong> purchase or an authorized serviceman. Improper installation could lead to leaks and in<br />
worst cases, electric shock <strong>of</strong> fire.<br />
• Use only parts provided with the unit or parts satisfying required specifications. Unspecified parts could cause the unit to<br />
fall out <strong>of</strong> <strong>pl</strong>ace, or could lead to leaks and in the worst cases, electric shock or fire.<br />
Installation <strong>of</strong> indoor unit 321
Ceiling cassette 4-way<br />
3.2 Ceiling cassette 4-way<br />
• Please read the instruction sheets com<strong>pl</strong>etely before installing the product.<br />
• When the power cord is damaged, re<strong>pl</strong>acement work shall be performed by authorized personnel only.<br />
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.<br />
Name<br />
Quantity<br />
Air sup<strong>pl</strong>y<br />
3.2.1 Accessories<br />
Check whether the following accessories are included with your unit.<br />
1) Standard accessories<br />
Drain hose<br />
1 EA<br />
Air<br />
return<br />
Clamp metal<br />
1 EA<br />
Washer for<br />
hanging backet<br />
8 EA<br />
Clamp<br />
Insulation for<br />
fitting<br />
1 SET<br />
Shape for gas pipe<br />
for liquid pipe<br />
5CSL0-06B<br />
322 Installation <strong>of</strong> indoor unit<br />
8 EA<br />
Long life filter<br />
(Other)<br />
• Paper pattern for<br />
installation<br />
• Owner's manual<br />
• Installation manual
5CSL0-06B Ceiling cassette 4-way<br />
3.2.2 Selection <strong>of</strong> the best location<br />
• There should not be any heat source or steam near the<br />
unit.<br />
• There should not be any obstacles to the air circulation.<br />
• There should be provision <strong>of</strong> easy condensate drain.<br />
• Taking into accounting the noise prevention criteria, spot<br />
the installation location.<br />
• Do not install the unit near the door way.<br />
• Keep proper distances, <strong>of</strong> the unit, from ceiling, fence,<br />
floor, walls and other obstacles as shown in figure.<br />
• The indoor unit must have the maintenance space.<br />
NOTE<br />
Ceiling<br />
False ceiling<br />
1500 or<br />
more<br />
Above figure means minimum value. Please keep these<br />
value at least.<br />
If H is 2700~3200: High ceiling operation control requied<br />
If H is ~2700: Normal operation<br />
1500 or more<br />
1500<br />
or more<br />
20 or more<br />
1500 or more<br />
H<br />
Floor<br />
1500 or<br />
more<br />
1500 or more<br />
False ceiling<br />
1500 or more<br />
Unit:mm<br />
3.2.3 Precautions regarding cassette<br />
indoor unit installation<br />
1) Main points about the indoor installation<br />
• In case <strong>of</strong> high height ceiling<br />
In general commercial <strong>pl</strong>aces and <strong>of</strong>fices though the<br />
height <strong>of</strong> the ceiling is 2.7 m, the ceiling height can be 3<br />
m. In such cases because <strong>of</strong> the temperature difference<br />
with the floor the heating effect can fall down.<br />
High elevation<br />
<strong>of</strong> the ceiling<br />
Discharge<br />
• Countermeasure method<br />
① Air conditioner must be able to operate in high ceiling<br />
conditioner.<br />
② Plan to install the circulator.<br />
③ The air discharge port is made to give more airflow to the<br />
down wood directions.<br />
④ The gate or exit <strong>of</strong> the building is protected by dual door<br />
system.<br />
2) In case the floor or surfaces <strong>of</strong> the <strong>pl</strong>ace<br />
to be air conditioned is in direct contact<br />
with the outdoor air<br />
• The floor <strong>of</strong> the heating room indirect contact with<br />
the storeroom, garage or the outside air receives<br />
the cold air at the floor and the floor temperature<br />
decrease will feel cold at the feet.<br />
Outdoor side<br />
In such <strong>pl</strong>aces where the feet comes in direct contact<br />
with floors will give a cold feeling to the floor.<br />
Installation <strong>of</strong> indoor unit 323<br />
Suction<br />
Hot air<br />
Cold air<br />
Indoor<br />
Outdoor side<br />
Garage<br />
Outdoor<br />
side (Entering <strong>of</strong> air by<br />
frequent opening<br />
and closing <strong>of</strong> door)<br />
Low temperature<br />
<strong>of</strong> the floor<br />
(50~100mm<br />
Insulation required)<br />
Outdoor side
Ceiling cassette 4-way<br />
• Countermeasure:<br />
- Use the carpet on the floor (compared to the tiles the carpet<br />
over it will have a 3 degree rise in temperature)<br />
- Insulating the floor.<br />
- Floor heating<br />
CAUTION<br />
• Case <strong>of</strong> cold air intake:<br />
The duct surface will have the dew drops so a insulation<br />
on the duct is a must.(Insulation material: a glass wool <strong>of</strong><br />
thickness 25 mm will be appropriate.)<br />
3) In case <strong>of</strong> high temperature or high<br />
humidity between the false ceiling and<br />
ceiling slab(near by the sea, river, lake,<br />
spa)<br />
• In case <strong>of</strong> temperature <strong>of</strong> 30 degree and humidity<br />
above 80%, the units body as well as the piping<br />
insulation should be strengthened.<br />
Refer to the picture given below.<br />
Psychrometric chart Enhance additional<br />
insulation required area<br />
Relative humidity<br />
30˚C<br />
• Places having the temperature and humidity <strong>of</strong> the<br />
surrounding and the<br />
The surrounding water sources(sea, river etc.)<br />
In case the steam is generated between the false ceiling<br />
and the ceiling slab<br />
Due to some nearby by steam source.<br />
- Indoor unit: Insulate the unit body with some insulation<br />
like glass wool atleast 10 mm in thickness.<br />
Additional insulation required<br />
5CSL0-06B<br />
• In case <strong>of</strong> the multi flow type, use the high humidity kit.<br />
Otherwise the dew drops can be seen in the unit body.<br />
• Refrigerant piping: Increase the piping insulation<br />
thickness with thickness above 20 mm.<br />
• Others: Inside the ceiling near th air tight seal <strong>pl</strong>aces<br />
(no escape <strong>of</strong> the humidity)<br />
Grill for ventilation<br />
Refrigerant piping<br />
• In case <strong>of</strong> multi<strong>pl</strong>e indoor cassette units<br />
(recommended)<br />
Indoor unit<br />
Above 1500mm<br />
324 Installation <strong>of</strong> indoor unit<br />
Lighting<br />
Ventilator<br />
Above 2000mm<br />
Above 3000mm<br />
Indoor unit
5CSL0-06B Ceiling cassette 4-way<br />
3.2.4 Ceiling opening dimensions and<br />
hanging bolt location<br />
① The dimensions <strong>of</strong> the paper pattern for installation are<br />
the same as those <strong>of</strong> the ceiling opening dimensions.<br />
② Select and mark the position for fixing bolts and piping<br />
hole.<br />
③ Decide the position for fixing bolts slightly tilted to the<br />
drain direction after considering the direction <strong>of</strong> drain<br />
hose.<br />
④ Drill the hole for anchor bolt on the wall.<br />
39.5<br />
671<br />
TQ,TR MODEL<br />
600 (Ceiling opening)<br />
521(Hanging bolt) 39.5<br />
570 Unit siz size<br />
570 Unit siz size<br />
TP/TN/TM Model<br />
875(Ceiling opening)<br />
787(Hanging bolt)<br />
840 Unit size<br />
840 Unit size<br />
684(Hanging bolt)<br />
450 (Hanging bolt) 75<br />
75<br />
600 (Ceiling opening)<br />
Unit:mm<br />
875(Ceiling opening)<br />
Unit:mm<br />
1) Install the suspension bolts.<br />
(Use either a W3/8” or M10 size bolt) Use a hole-in anchor<br />
for existing ceilings, and a sunken insert, sunken anchor or<br />
other field sup<strong>pl</strong>ied parts for new ceilings to reinforce the<br />
ceiling to bear the weight <strong>of</strong> the unit. Adjust clearance from<br />
the ceiling before proceeding further.<br />
All the above parts are field suppiled.<br />
Installation <strong>of</strong> indoor unit 325<br />
NOTE<br />
Ceiling<br />
Anchor<br />
Long nut or turn-buckle<br />
Suspension bolt<br />
False ceiling
Ceiling cassette 4-way<br />
3.2.5 Indoor unit installation<br />
• Installing <strong>of</strong> the accessories (except for the decoration<br />
panel) before installing the indoor unit is easier.<br />
1) Install the indoor unit temporarily.<br />
• Attach the hanger bracket to the suspension bolt. Be sure<br />
to fix it securely by using a nut and washer from the upper<br />
and lower sides <strong>of</strong> the hanger bracket.<br />
Hanging bolt<br />
(W3/8 or M10)<br />
Nut<br />
(W3/8 or M10)<br />
Spring washer<br />
(M10)<br />
Keep the length<br />
<strong>of</strong> the bolt<br />
from the bracket<br />
to 40mm or more<br />
Adjust the same height<br />
Ceiling<br />
Air conditioner body<br />
• The following parts are local purchasing.<br />
- Hanging Bolt - W 3/8 or M10<br />
- Nut - W 3/8 or M10<br />
- Spring Washer - M10<br />
- Plate Washer - M10<br />
Flat washer for M10<br />
(accessory)<br />
Flat washer for M10<br />
(accessory)<br />
Nut<br />
(W3/8 or M10)<br />
False ceiling<br />
2) For new ceilings<br />
(1) Refer to the paper pattern for ceiling opening<br />
dimension.<br />
• The center <strong>of</strong> the ceiling opening is indicated on the<br />
paper pattern for installation.<br />
The center <strong>of</strong> the unit is indicated on the label attached<br />
to the unit and on the paper pattern for installation.<br />
• First remove paper packaging material from the<br />
4 corners <strong>of</strong> the paper pattern for installation , fix the<br />
paper pattern to the unit with screws.<br />
• Ceiling height is shown on the side <strong>of</strong> the paper pattern<br />
for installation. Adjust the height <strong>of</strong> the unit according to<br />
this indication.<br />
5CSL0-06B<br />
<br />
(2) Adjust the unit to the right position for installation.<br />
(3) Assure that the unit is horizontal.<br />
• The indoor unit is equipped with a built-in drain pump<br />
and float switch. At each <strong>of</strong> the unit's 3 corners, verify<br />
that it is level by using awater-level or a water-filled<br />
vinyl tube. (Otherwise it will result in the malfunctioning<br />
<strong>of</strong> unit and cause water to drip.)<br />
(4) Remove the washer fixing <strong>pl</strong>ate used for<br />
preventing the washer from falling and tighten<br />
the upper nut.<br />
(5) Remove the paper pattern for installation<br />
3) For existing ceilings<br />
(1) Adjust the height and position <strong>of</strong> the unit.<br />
(2) Perform steps 3 and 4 in "5.1 For new ceilings".<br />
3.2.6 Connecting pipes to the indoor<br />
unit<br />
1) Refrigerant piping work<br />
<strong>pl</strong>ease refer “REFRIGERANT PIPING WORK”.<br />
2) Piping insulation<br />
① Perform heat insulation work com<strong>pl</strong>etely on both gas and<br />
the liquid pipe. Because improper insulation will result<br />
condensate formation over pipe.<br />
② Use the heat insulation material for the refrigerant piping<br />
which has an excellent heat resistance (over 120°C).<br />
③ Precautions in high humidity circumstance:<br />
④ Refer to insulation work<br />
CAUTION<br />
• Make sure to insulate any field piping all the way to the<br />
piping connection inside the unit. Any exposed piping<br />
may cause condensation or burns if touched.<br />
326 Installation <strong>of</strong> indoor unit
5CSL0-06B Ceiling cassette 4-way<br />
3) Indoor unit drain piping<br />
• Drain piping must have downward (1/50 to 1/100): be sure<br />
not to provide up-and-down slope to prevent reverse flow.<br />
• During drain piping connection, be careful not to exert<br />
extra force on the drain port on the indoor unit.<br />
• The outside diameter <strong>of</strong> the drain connection on the inddor<br />
unit is 32mm.<br />
Piping material: Polyvinyl chloride pipe 25mm and pipe<br />
fittings<br />
p<br />
• Be sure to install heat insulation on the drain piping.<br />
Heat insulation material: Polyethylene foam with thickness<br />
more than 10 mm.<br />
4) Drain test<br />
Sqeezing<br />
Water feeder<br />
Drain pump<br />
Drain pan<br />
1/50~<br />
1/100<br />
MAX<br />
700mm<br />
Upward<br />
routing<br />
not allowed<br />
Flexible drain hose<br />
(Accessory)<br />
Main<br />
drain pipe<br />
Drain<br />
port Glue the joint<br />
Drain hose connection<br />
use the clip (Accessory)<br />
Flexible drain hose<br />
3.2.7 Decoration panel<br />
The decoration panel has its installation<br />
direction.<br />
Before installing the decoration panel, always<br />
remove the paper tem<strong>pl</strong>ate.<br />
1. Temporarily fix two decoration panel fixing screws<br />
(hexagon M5 screw) on the unit body. (Tighten by<br />
amount 10mm in length.)<br />
The fixing screws (hexagon M5 screw) are included<br />
the indoor unit box.<br />
2. Remove the air inlet grille from the decoration panel.<br />
(Remove the hook for the air inlet grille cord.)<br />
3. Hook the decoration panel key hole ( ) on the<br />
screws fixed in step above, and slide the panel so that<br />
the screws reach the key hole edge.<br />
4. Retighten com<strong>pl</strong>etely two temporarily fixed screws and<br />
other two screws. (Total 4 screws)<br />
5. Connect the louver motor connector and dis<strong>pl</strong>ay connector.<br />
6. After tightening these screws, install the air inlet grille<br />
(including the air filter).<br />
Decoration panel fixing screws<br />
(hexagon M5 screws)<br />
Temporally fitting at 2 <strong>pl</strong>aces<br />
(Tightening about 10mm)<br />
Inlet Grille<br />
Air conditioner unit<br />
Piping side<br />
Decoration panel<br />
Decoration panel fixing screws<br />
(Hexagon M5 M5 screw) screw)<br />
Control box cover<br />
Flexible drain hose<br />
Louver motor<br />
Installation <strong>of</strong> indoor unit 327<br />
Dis<strong>pl</strong>ay<br />
Lead wire for<br />
louver motor and<br />
dis<strong>pl</strong>ay
Ceiling cassette 4-way<br />
CAUTION<br />
Install certainly the decoration panel.<br />
Cool air leakage causes sweating.<br />
➔ Water drops fall.<br />
3.2.8 Electric wiring work<br />
1) General instructions<br />
Air conditioner<br />
unit<br />
Decoration panel<br />
Fit the insulation (this part) and<br />
be careful for cool air leakage<br />
Air<br />
False<br />
ceiling<br />
Air conditioner unit<br />
Cool air leakage(no good)<br />
False<br />
ceiling<br />
Decoration panel<br />
① All field sup<strong>pl</strong>ied parts and materials, electric works must<br />
conform to local codes.<br />
Use copper wire only.<br />
② Follow the "WIRING DIAGRAM” attached to the unit<br />
body to wire the outdoor unit, indoor units and the remote<br />
controller.<br />
③ All wiring must be performed by an authorized electrician.<br />
④ This system consists <strong>of</strong> multi<strong>pl</strong>e indoor units. Mark each<br />
indoor unit as unit A, unit B..., and be sure the terminal<br />
board wiring to the outdoor unit and indoor units are<br />
properly matched. If wiring and piping between the outdoor<br />
unit and an indoor units are mismatched, the system<br />
may cause a malfunction.<br />
⑤ A circuit breaker capable <strong>of</strong> shutting down the power<br />
sup<strong>pl</strong>y to the entire system must be installed.<br />
5CSL0-06B<br />
2) Wiring Connection<br />
① Open the control box cover and connect the Remote<br />
controller cord and Indoor power wires.<br />
Indoor<br />
power cable<br />
Remote<br />
controller<br />
cable<br />
Control Box Cover Control box<br />
cover screw<br />
Indoor<br />
power<br />
cord<br />
Terminal block in indoor<br />
[Air inlet side view]<br />
1(L) 2(N) 3 4<br />
Connected to outdoor Unit<br />
Remote<br />
control<br />
cord<br />
② Make sure to attach the sealing material (field sup<strong>pl</strong>ied)<br />
to hole <strong>of</strong> wiring to prevent the infiltration <strong>of</strong> foreign particle<br />
from outside. Otherwise a short-circuit may occur<br />
inside the electric parts box<br />
328 Installation <strong>of</strong> indoor unit
5CSL0-06B Ceiling cassette 4-way<br />
③ When clamping the wires, be sure no pressure is ap<strong>pl</strong>ied<br />
to the wire connections by using the included clamping<br />
material to make appropriate clamps. Also, when wiring,<br />
make sure the cover on the electric parts box fits snugly<br />
by arranging the wires neatly and attaching the electric<br />
parts box cover firmly. When attaching the electric parts<br />
box cover, make sure no wires get caught in the edges.<br />
Pass wiring through the holes to prevent damage to<br />
them.<br />
④ Make sure the remote controller wiring, the wiring<br />
between the units, and other electrical wiring do not pass<br />
through the same locations outside <strong>of</strong> the unit, separating<br />
them properly, otherwise electrical noise (external<br />
static) could cause product malfunction.<br />
NOTE<br />
WARNING<br />
• Make sure that the screws <strong>of</strong> the terminal are not loose.<br />
1. Use round crimp-style terminals for connecting<br />
wires to the power sup<strong>pl</strong>y terminal block. If<br />
unavailable, observe the following points when<br />
wiring.<br />
• Do not connect wires <strong>of</strong> different gauge to the same<br />
power sup<strong>pl</strong>y terminal. (Looseness connection may<br />
cause overheating.)<br />
• Use the specified electric wire. Connect the wire<br />
securely to the terminal. Lock the wire down without<br />
ap<strong>pl</strong>ying excessive force to the terminal.<br />
Round crimp-style terminal<br />
Attach insulation sleeve<br />
Electricwire<br />
Connect wires <strong>of</strong> the same gauge to both sides<br />
2. Tightening torque for the terminal screws.<br />
• Use the correct screwdriver for tightening the terminal<br />
screws. If the blade <strong>of</strong> screwdriver is too small, the<br />
head <strong>of</strong> the screw might be damaged, and the screw<br />
will not be properly tightened.<br />
• If the terminal screws are tightened too hard, screws<br />
might be damaged.<br />
3. Do not connect wires <strong>of</strong> different gauge to the<br />
same grounding terminal. Loose connection may<br />
deteriorate protection.<br />
4. At the unit, keep proper separation between transmissio<br />
and power sup<strong>pl</strong>y wiring.<br />
The equipment may malfunction if subjected to<br />
electrical (external) noise.<br />
5. Never connect power sup<strong>pl</strong>y wiring to the terminal<br />
block for remote controller wiring. A mistake <strong>of</strong><br />
the sort could damage the entire system.<br />
6. Use only specified wire and tightly connect wires<br />
to terminals. Be careful that wires should not<br />
<strong>pl</strong>ace external stress on terminals. Keep wiring in<br />
neat order and so as not to obstruct other equipment<br />
such as popping open the electric parts box<br />
cover. Make sure the cover closes tight.<br />
Incom<strong>pl</strong>ete connections could result in overheating,<br />
and in worst case, electric shock or fire.<br />
CAUTION<br />
After the confirmation <strong>of</strong> the above conditions, prepare the<br />
wiring as follows:<br />
1) Never fail to have an individual power circuit specifically<br />
for the air conditioner. As for the method <strong>of</strong> wiring, be<br />
guided by the circuit diagram posted on the inside <strong>of</strong><br />
control cover.<br />
2) The screw which fasten the wiring in the casing <strong>of</strong> electrical<br />
fittings are liable to become loose from vibrations<br />
to which the unit is subjected during the course <strong>of</strong> transportation.<br />
Check them and make sure that they are all<br />
tightly fastened. (If they are loose, it could cause burnout<br />
<strong>of</strong> the wires.)<br />
3) Confirm the specification <strong>of</strong> power source.<br />
4) Confirm that electrical capacity is sufficient.<br />
5) See to that the starting voltage is maintained at more<br />
than 90 percent <strong>of</strong> the rated voltage marked on the<br />
name <strong>pl</strong>ate.<br />
6) Confirm that the cable thickness is as specified in the<br />
power source specification.<br />
(Particularly note the relation between cable length and<br />
thickness.)<br />
7) Always install an earth leakage circuit breaker in a wet<br />
or moist area.<br />
8) The following would be caused by voltage drop.<br />
• Vibration <strong>of</strong> a magnetic switch, which will damage the<br />
contact point, fuse breaking, disturbance <strong>of</strong> the normal<br />
function <strong>of</strong> the overload.<br />
9) The means for disconnection from a power sup<strong>pl</strong>y shall<br />
be incorporated in the fixed wiring and have an air gap<br />
contact separation <strong>of</strong> at least 3mm in each<br />
active(phase) conductors.<br />
Installation <strong>of</strong> indoor unit 329
Ceiling and floor, Ceiling suspended only<br />
3.3. Ceiling and floor, Ceiling suspended only<br />
• Please read the instruction sheets com<strong>pl</strong>etely before installing the product.<br />
• When the power cord is damaged, re<strong>pl</strong>acement work shall be performed by authorized personnel only.<br />
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.<br />
1) Installation parts provided<br />
① Installation Plate (VB, 2pcs)<br />
② Installation Plate (VE, 1pcs)<br />
③ Washer Bolt (M8×L25, 4pcs, type "A")<br />
④ Floor Mount Bracket (1pcs)<br />
⑤ Drain Hose, Insulated<br />
⑥ Drain Hose Hanger and screw<br />
2) The other installation parts needed<br />
⑦ Suspension Bolt<br />
⑧ Bolts for Mount Bracket<br />
- Connecting Tube(mm)<br />
• Gas side : Ø12.7, Ø15.88, Ø9.52<br />
• Liquid side : Ø6.35, Ø9.52<br />
- Connecting Cable<br />
- Drain Hose for extention<br />
2<br />
(Floor mounting)<br />
5CSL0-06B<br />
330 Installation <strong>of</strong> indoor unit<br />
7<br />
6<br />
8<br />
4<br />
1<br />
(Ceiling/wall mounting)<br />
3.3.1 How to set Floor/Ceiling selection button (UV09 NED,UV12 NED)<br />
CN_ CENTRAL<br />
CONTROL<br />
CN_ WRITE<br />
CN_ DISPLAY<br />
CN_ OPTION<br />
CN_ REMO<br />
CN_ PIPE/OUT<br />
SW01<br />
CVT 5:Install<br />
Off (Factory Set) Ceiling<br />
On Bottom<br />
CN_ PIPE/IN CN_ ROOM<br />
CN_ vain 1<br />
CN_ vain 2<br />
CN_ DOOR CN_ MOTOR1<br />
CN_ MOTOR2<br />
BOTTOM INSTALLATION : SET No.5 SW "ON"<br />
CEILING INSTALLATION : NO NEED TO SET SW01 MAIN PCB.<br />
CN_ POWER<br />
5<br />
3
5CSL0-06B Ceiling and floor, Ceiling suspended only<br />
3.3.2 Selection <strong>of</strong> the best location<br />
• There should not be any heat source or steam near the<br />
unit.<br />
• There should not be any obstacles to the air circulation.<br />
• There should be provision <strong>of</strong> easy condensate drain.<br />
• Taking into accounting the noise prevention criteria, spot<br />
the installation location.<br />
• Do not install the unit near the door way.<br />
• Keep proper distances, <strong>of</strong> the unit, from ceiling, fence,<br />
floor, walls and other obstacles as shown in figure.<br />
• The indoor unit must have the maintenance space.<br />
• The mounting ceiling or wall should be strong and solid<br />
enough to protect it from the vibration.<br />
More than<br />
20cm<br />
More than eye-level<br />
More than<br />
20cm<br />
3.3.3 Installation<br />
(Ceiling installation)<br />
(Floor/wall installation)<br />
Models : UV18, UV24, UV30<br />
More than<br />
20cm<br />
1. Before Installing, prepare Installation<br />
Plates<br />
• 'Installation Plates' are attached at the bottom <strong>of</strong> indoor<br />
unit.<br />
Detach them by removing each 3 screws at both sides.<br />
• Pull the upper right and left side <strong>of</strong> 'Inlet Grille' to the front,<br />
and it will stop at slightly tilted position.<br />
• Unhook the 'Inlet hanger' from the 'Hanger screw' on the<br />
both left and right side.<br />
• Detach the 'Inlet Grille' from the Indoor Unit.<br />
• Detach 'Side Plate (R,L)' by removing each 3 screws on<br />
both sides.<br />
R<br />
R<br />
More than<br />
20cm<br />
Install Plate<br />
Inlet Grille<br />
Side Plate<br />
Inlet hanger<br />
1) Installation on the ceiling<br />
① Measure and mark the position for the Suspension bolts<br />
and the piping hole.<br />
② Drill the hole for anchor nut on the ceiling.<br />
Drill the piping hole on the wall slightly tilted to the outdoor<br />
side using a ø70 hole-core drill.<br />
❈ Before secure the Installation Plates, select the bent<br />
direction <strong>of</strong> the Installion Plate to the inside or the outside<br />
according to the installation circumstances.<br />
Installation <strong>of</strong> indoor unit 331<br />
1)<br />
2)<br />
1076<br />
Suspension<br />
bolt<br />
R<br />
265<br />
Hanger<br />
screw<br />
Center-line for the<br />
piping hole<br />
1236 265<br />
Indoor WALL<br />
Outdoor<br />
5~7mm
Ceiling and floor, Ceiling suspended only<br />
③ Insert the nuts and washer onto the suspension bolts for<br />
locking the suspension bolts on the ceiling.<br />
④ Mount the suspension bolts to the anchor-nuts firmly.<br />
⑤ Secure the installation <strong>pl</strong>ates onto the suspension bolts<br />
(adjust level roughly) using nuts, washers and spring<br />
washers.<br />
1<br />
2<br />
Suspension<br />
bolts<br />
Spring<br />
washer<br />
Nut<br />
max.<br />
12mm Washer<br />
Ceiling<br />
Nut<br />
Suspension<br />
bolts<br />
Anchor nut<br />
Washer<br />
⑥ Engage 2 hooks on the both left and right side <strong>of</strong> the unit<br />
to the lower slot <strong>of</strong> Installation <strong>pl</strong>ates.<br />
⑦ Adjust a level with a level gauge on the direction <strong>of</strong> leftright,<br />
back-forth by adjusting suspension bolts.<br />
⑧ Move the hooks on the unit to the upper slot <strong>of</strong> installation<br />
<strong>pl</strong>ates. Then the unit will be declined to the bottomside<br />
so as to drain well.<br />
Suspension<br />
bolt<br />
Lower slot<br />
Level gauge<br />
R<br />
Installation <strong>pl</strong>ate<br />
Adjust a level<br />
5CSL0-06B<br />
⑨ Secure the unit to the installation <strong>pl</strong>ates with four M8<br />
bolts and washers.<br />
⑩ Before working, refer to 'Connecting pipe and cable to<br />
indoor unit.<br />
⑪ Fit the projection hooks <strong>of</strong> the side <strong>pl</strong>ates to the 'Side<br />
Panel'<br />
⑫ Fasten the screws.<br />
332 Installation <strong>of</strong> indoor unit<br />
R<br />
R<br />
R<br />
R<br />
R<br />
Upper slot
5CSL0-06B Ceiling and floor, Ceiling suspended only<br />
⑬ Hook up the Inlet Grille Hook to the cabinet. • Fit the projection hooks <strong>of</strong> the side <strong>pl</strong>ates to the 'Side<br />
Panel' and the 'Front Panel' by lifting it.<br />
Inlet hanger<br />
• Fasten the screws.<br />
CAUTION : Installation Information For Declination<br />
1. Install declination <strong>of</strong> the indoor unit is very important for the drain <strong>of</strong> the convertible type air conditioner.<br />
2. Minimum thickness <strong>of</strong> the insulation for the connecting pipe shall be 10mm.<br />
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be declined to the bottomside.<br />
Drain hose<br />
R<br />
Hook<br />
Cabinet Bottom<br />
5~10mm<br />
10~20mm<br />
Front <strong>of</strong> view<br />
• The unit must be horizontal or inclined at angle.<br />
• The inclination should be less than or equal to 1° or in between 10 to 20mm inclined in drain<br />
direction as shown in fig.<br />
Ceiling<br />
Ceiling<br />
Side <strong>of</strong> view<br />
Ceiling<br />
10~20mm<br />
• The unit must be declined to the bottomside <strong>of</strong> the unit when finished installation.<br />
Installation <strong>of</strong> indoor unit 333<br />
1<br />
R<br />
R<br />
2
Ceiling and floor, Ceiling suspended only<br />
2) Installation on the Wall<br />
① Select and mark the position for fixing bolts and piping<br />
hole.<br />
Decide the position for fixing bolts slightly tilted to the<br />
drain direction after considering the direction <strong>of</strong> drain<br />
hose.<br />
② Drill the hole for anchor nut on the wall.<br />
③ Secure the 'Install <strong>pl</strong>ate' onto the wall with four anchor<br />
bolts, washers and spring washers.<br />
Nut<br />
Spring<br />
washer<br />
more than<br />
260<br />
Washer<br />
Anchor nut<br />
Less than<br />
12mm<br />
Wall<br />
1076<br />
※ Before securing the installation <strong>pl</strong>ates, select the bent<br />
direction <strong>of</strong> the 'Installation <strong>pl</strong>ates' to the inside or outside<br />
according to the installation circumstances.<br />
1236<br />
265<br />
Unit: mm<br />
Unit: mm<br />
5CSL0-06B<br />
3) Install the indoor unit on the installation <strong>pl</strong>ate.<br />
① Insert 2 hooks on the both left and right side <strong>of</strong> the unit to<br />
the inner slot (wall side) <strong>of</strong> the Installation Plate.<br />
② Secure the unit to the Installation Plate with four M8 bolts<br />
and washers.<br />
• Before working, refer to "Connecting pipe<br />
and cable to Indoor Unit".<br />
③ Fit the projection hooks <strong>of</strong> the side <strong>pl</strong>ates to the 'Side<br />
Panel' and the 'Front Panel' by lifting it.<br />
④ Fasten the screws.<br />
⑤ Hook up the Inlet Grille Hook to the cabinet.<br />
⑥ Hang the Inlet Hanger to the screw.<br />
334 Installation <strong>of</strong> indoor unit<br />
R<br />
Inner slot
5CSL0-06B Ceiling and floor, Ceiling suspended only<br />
4) Installation on the floor<br />
Installation <strong>of</strong> mount bracket.<br />
① Select and mark the position for Mount Brackets and the<br />
piping hole.<br />
② Drill the hole for the anchor nut on the wall.<br />
③ Drill the piping hole using a ø70 hole-core drill.<br />
④ Secure the mount brackets on the wall with four M4<br />
screws.<br />
5) Install the indoor unit on the mount brackets.<br />
① Engage the slot at the back <strong>of</strong> the unit with mount bracket.<br />
Slot<br />
Floor mount<br />
bracket<br />
From the left wall<br />
more than 760mm<br />
From the<br />
right wall<br />
more than 840mm<br />
448mm<br />
6) After installing, reassemble detached parts.<br />
① Hang the 'Inlet grille' and hook the 'Inlet hanger' to the<br />
hanger screw.<br />
② Assemble the 'Side <strong>pl</strong>ates(R,L)' with 2 screws on both<br />
left and right side.<br />
Slot<br />
Wall<br />
Floor mount<br />
bracket<br />
Install <strong>pl</strong>ate<br />
Piping hole<br />
Models : UV38, UV42, UV48, UV60<br />
1) Installation on the ceiling<br />
① Prepare 4 suspension bolts (Each bolts length should be<br />
same.)<br />
② Measure and mark the position for the suspension bolts<br />
and the piping hole.<br />
③ Insert the nuts and washer onto the suspension bolts for<br />
locking the suspension bolts on the ceiling.<br />
④ Mount the suspension bolts to the anchor-nuts firmly.<br />
⑤ Secure the hangers onto the suspension bolts (adjust<br />
level roughly) using nuts, washers and spring washers.<br />
⑥ Adjust a level with a level gauge on the direction <strong>of</strong> leftright,<br />
back-forth by adjusting suspension bolts.<br />
⑦ Adjust a level on the direction <strong>of</strong> top-bottom by adjusting<br />
supension bolts. Then the unit will be declined to the bottomside<br />
so as to drain well.<br />
Nut<br />
Suspension<br />
bolts<br />
piping hole<br />
(Ø45)<br />
Suspension bolt<br />
Installation <strong>of</strong> indoor unit 335<br />
Ceiling<br />
Anchor nut<br />
CAUTION<br />
Washer<br />
40<br />
820<br />
Suspension<br />
bolts<br />
Spring<br />
washer<br />
Hangen<br />
Max.<br />
12mm<br />
235<br />
Nut<br />
Washer<br />
50<br />
100<br />
Reference<br />
<strong>of</strong> piping<br />
hole (Ø25)<br />
• Tighten the nut and bolt to prevent unit from falling.
Ceiling and floor, Ceiling suspended only<br />
Hanging bolt<br />
(W3/8 or M10)<br />
Nut<br />
(W3/8 or M10)<br />
Spring washer<br />
(M10)<br />
2) Installation on the wall<br />
Flat washer for M10<br />
(accessory)<br />
Flat washer for M10<br />
(accessory)<br />
Nut<br />
(W3/8 or M10)<br />
The wall you select should be strong enough to prevent<br />
vibration<br />
① Mount the installation <strong>pl</strong>ate on the wall with<br />
type "A" screws. If mounting the unit on a concrete wall,<br />
use anchor bolts.<br />
② Mount the installation <strong>pl</strong>ate horizontally by aligning the<br />
centerline using a level.<br />
Type "A" screw<br />
Installation Plate<br />
③ Measure the wall and mark the centerline. It is also<br />
important to use caution concerning the location <strong>of</strong> the<br />
installation <strong>pl</strong>ate-routing <strong>of</strong> the wiring to power outlets is<br />
through the walls typically. Drilling the hole through the<br />
wall for piping connections must be done safely.<br />
70<br />
Ø70mm<br />
Installation <strong>pl</strong>ate<br />
120<br />
Left rear piping more than 200<br />
Right rear piping<br />
Foor<br />
Ø70mm<br />
70<br />
Models : UV36, UV42, UV48, UV60<br />
1) Open side cover<br />
5CSL0-06B<br />
1. Remove two screws from side-cover as shown in fig.<br />
2. Unlock side-cover from side panel by slightly pulling<br />
the edge <strong>of</strong> side cover.<br />
3. Tap the side-cover with your palm on the<br />
backside.(Inlet grill side.)<br />
4. Hold the side-cover with other hand while tapping to<br />
prevent it to fall down.<br />
Recommendation: it is recommended to select the left<br />
side for drain to have common hole in the side-cover<br />
along with pipe and wiring.<br />
5. Remove the rubber stop<strong>pl</strong>e in the desired drain<br />
direction.<br />
6. Knock out the pipe hole from the left side-cover with<br />
the help or nipper/<strong>pl</strong>ier.<br />
7. Knock hole on right side-cover only if right side is<br />
selected for water drain.<br />
336 Installation <strong>of</strong> indoor unit<br />
2<br />
Edge part<br />
1
5CSL0-06B Ceiling and floor, Ceiling suspended only<br />
2) Mounting the anchor nut and bold<br />
• Prepare 4 suspension bolts. (Each bolts length<br />
should be same.)<br />
• Measure and mark the position for the Suspension<br />
bolts and the piping hole.<br />
• Drill the hole for anchor nut on the ceiling.<br />
• Insert the nuts and washer onto the suspension<br />
bolts for locking the suspension bolts on the ceiling.<br />
• Mount the suspension bolts to the anchor-nuts<br />
firmly.<br />
• Secure the hangers onto the Suspension bolts<br />
(adjust level roughly.) using nuts, washers and<br />
spring washers.<br />
• Adjust a level with a level gauge on the direction<br />
<strong>of</strong> left-right, back-forth by adjusting suspension<br />
bolts.<br />
• Adjust a level on the direction <strong>of</strong> top-bottom by<br />
adjusting supension bolts. Then the unit will be<br />
declined to the bottomside so as to drain well.<br />
MODEL<br />
DIM.<br />
A B<br />
VL 1655 320<br />
VK 1255 320<br />
VJ 855 320<br />
Ceiling<br />
Nut<br />
Suspension<br />
bolts<br />
Anchor nut<br />
Washer<br />
A<br />
Suspension bolt<br />
Suspension<br />
bolts<br />
Spring<br />
washer<br />
Hangen<br />
Max.<br />
12mm<br />
B<br />
Nut<br />
Washer<br />
3.3.4 Piping and drainage<br />
1) Installation on the ceiling<br />
• Connecting the pipes to the indoor unit<br />
The pipe can be connected to right side, bottom or back <strong>of</strong><br />
the unit.<br />
• For the right side piping<br />
① After bending an end <strong>of</strong> the connecting tube, align the<br />
center <strong>of</strong> the pipings and sufficiently tighten the flare nut<br />
with fingers.<br />
② Finally, tighten the flare nut with torque wrench until the<br />
wrench clicks.<br />
③ Connect the drain hose insulated to the drain outlet. Drain<br />
hose should go under the hose bracket as shown in figure ❹.<br />
④ Hang the drain hose on the hose hanger and fix it to the<br />
hole <strong>of</strong> the hose bracket with a screw.<br />
Installation <strong>of</strong> indoor unit 337<br />
R<br />
4<br />
R<br />
Piping<br />
2<br />
Drain hose<br />
Hose hanger<br />
5<br />
1<br />
Hose<br />
Bracket<br />
3
Ceiling and floor, Ceiling suspended only<br />
• For the bottom side piping<br />
① Remove the knock-out from the bottomside <strong>of</strong> inlet grille<br />
② Align the center <strong>of</strong> the pipings and sufficiently tighten the<br />
flare nut with fingers.<br />
③ Finally, tighten the flare nut with torque wrench until the<br />
wrench clicks.<br />
④ Connect the drain hose insulated to the drain outlet.<br />
⑤ Hang the drain hose on the hose hanger and fix it to the<br />
hole <strong>of</strong> cabinet bottom with a screw.<br />
R<br />
Hose<br />
hanger<br />
• Connecting the drain hose<br />
① The drain hose can be connected to not only the right<br />
side but also left side <strong>of</strong> the unit.<br />
② If the drain hose is connected to the left side, it should go<br />
through the cabinet bottom.<br />
③ Hang the drain hose on the hose hanger and fix it to the<br />
hole <strong>of</strong> cabinet bottom with a screw.<br />
Hose hanger<br />
Drain hose<br />
Bottom<br />
5CSL0-06B<br />
2) Installation on the wall or floor<br />
• Connecting the pipes to the indoor unit<br />
• For the right rear piping<br />
① Remove the knock-out from the back side <strong>of</strong> the cabinet.<br />
② After bending an end <strong>of</strong> the connecting tube, align the<br />
center <strong>of</strong> the pipings and sufficiently tighten the flare nut<br />
with fingers.<br />
③ Finally, tighten the flare nut with torque wrench until the<br />
wrench clicks.<br />
④ Connect the drain hose to the drain outlet.<br />
⑤ Tape the drain hose to the pipings to avoid coming <strong>of</strong>f <strong>of</strong><br />
the drain-outlet.<br />
338 Installation <strong>of</strong> indoor unit<br />
Taping<br />
Taping<br />
Drain hose<br />
Wired remote<br />
control<br />
Drain hose<br />
Piping<br />
• For the right side piping<br />
① After bending an end <strong>of</strong> the connecting tube, align the<br />
center <strong>of</strong> the pipings and sufficiently tighten the flare nut<br />
with fingers.<br />
② Finally, tighten the flare nut with torque wrench until the<br />
wrench clicks.<br />
③ Connect the drain hose to the drain outlet.<br />
④ Tape the drain hose to the pipings to avoid coming <strong>of</strong>f<br />
the drain-outlet.<br />
Taping<br />
Drain hose<br />
Piping<br />
• For the right bottom piping<br />
① Align the center <strong>of</strong> the pipings and sufficiently tighten the<br />
flare nut with fingers.<br />
② Finally, tighten the flare nut with torque wrench until the<br />
wrench clicks.<br />
③ Connect the drain hose to the drain outlet.<br />
Piping<br />
Connecting<br />
Cable
5CSL0-06B Ceiling and floor, Ceiling suspended only<br />
• Connecting the drain hose<br />
① The drain hose can be connected to not only right side<br />
but also left side <strong>of</strong> the unit.<br />
Drain hose<br />
3) Checking the drainage<br />
• Remove the air filter.<br />
• Check the drainage.<br />
① Spray one or two glasses <strong>of</strong> water upon the evaporator.<br />
② Ensure that water flows through drain hose <strong>of</strong> indoor unit<br />
without any leakage.<br />
R<br />
R<br />
Rear<br />
Bottom<br />
① To remove air filter, take hold <strong>of</strong> tab and pull slightly<br />
upwards.<br />
3.3.5 Electric wiring work<br />
1) General instructions<br />
① All field sup<strong>pl</strong>ied parts and materials, electric works must<br />
conform to local codes.<br />
Use copper wire only.<br />
② Follow the "WIRING DIAGRAM” attached to the unit body to<br />
wire the outdoor unit, indoor units and the remote controller.<br />
③ All wiring must be performed by an authorized electrician.<br />
③ This system consists <strong>of</strong> multi<strong>pl</strong>e indoor units. Mark each<br />
indoor unit as unit A, unit B...., and be sure the terminal<br />
board wiring to the outdoor unit and indoor unit are properly<br />
matched. If wiring and piping between the outdoor unit and<br />
an indoor unit are mismatched, the system may cause a<br />
malfunction.<br />
④ A circuit breaker capable <strong>of</strong> shutting down the power sup<strong>pl</strong>y<br />
to the entire system must be installed.<br />
2) Wiring connection<br />
• Connecting cables to the indoor unit<br />
① Remove the air guide - L by loosening 2 screws after removing<br />
the inlet grille from the Indoor unit.<br />
② Connect the wires to the terminals on the control board individually<br />
according to the outdoor unit connection.<br />
• Ensure that the color <strong>of</strong> the wires <strong>of</strong> outdoor unit and the<br />
terminal No. are the same as those <strong>of</strong> indoor unit respectively<br />
Terminal block in indoor<br />
1(L) 2(N) 3 4<br />
Connected to outdoor Unit<br />
2) Clamping <strong>of</strong> cables<br />
① Arrange 2 power cables on the control panel.<br />
② First, fasten the steel clamp with a screw to the inner<br />
boss <strong>of</strong> control panel.<br />
③ For the cooling model, fix the other side <strong>of</strong> the clamp with<br />
a screw strongly.<br />
For the heat pump model, put the 0.75mm2 cable(thinner<br />
cable) on the clamp and tighten it with a <strong>pl</strong>astic clamp to<br />
the other boss <strong>of</strong> the control panel.<br />
④ In Australia, the length <strong>of</strong> power sup<strong>pl</strong>y cord measured<br />
from the entry <strong>of</strong> the power sup<strong>pl</strong>y cord to the middle <strong>of</strong><br />
live pin on the power <strong>pl</strong>ug should be over 1.8m.<br />
Installation <strong>of</strong> indoor unit 339
Ceiling and floor, Ceiling suspended only<br />
Air guide-l<br />
Indoor unit<br />
Clamp<br />
CAUTION<br />
CAUTION<br />
1<br />
Control<br />
panel<br />
• Make sure that the screws <strong>of</strong> the terminal are fixed<br />
tightly.<br />
• Make sure to attach the sealing material (field sup<strong>pl</strong>ied) to<br />
hole <strong>of</strong> wiring to prevent the infiltration <strong>of</strong> foreign particle<br />
from outside. Otherwise a short-circuit may occur inside the<br />
electric parts box<br />
• When clamping the wires, be sure no pressure is ap<strong>pl</strong>ied to<br />
the wire connections by using the included clamping material<br />
to make appropriate clamps. Also, when wiring, make<br />
sure the cover on the electric parts box fits snugly by<br />
arranging the wires neatly and attaching the electric parts<br />
box cover firmly. When attaching the electric parts box<br />
cover, make sure no wires get caught in the edges. Pass<br />
wiring through the holes to prevent damage to them.<br />
• Make sure the remote controller wiring, the wiring between<br />
the units, and other electrical wiring do not pass through the<br />
same locations outside <strong>of</strong> the unit, separating them properly,<br />
otherwise electrical noise (external static) could cause<br />
mistaken operation or breakage.<br />
R<br />
2<br />
5CSL0-06B<br />
1. Use round crimp-style terminals for connecting wires to<br />
the power sup<strong>pl</strong>y terminal block.<br />
If unavailable, observe the following points when wiring.<br />
① Do not connect wires <strong>of</strong> different gauge to the same power sup<strong>pl</strong>y<br />
terminal.<br />
② Use the specified electric wire. connect the wire securely to the<br />
terminal. Lock the wire down without ap<strong>pl</strong>ying excessive force<br />
to the terminal.<br />
2. Tightening torque for the terminal screws.<br />
① Use the correct screw driver for tightening the terminal screws.<br />
If the blade <strong>of</strong> screwdriver is too small, the head <strong>of</strong> the screw<br />
might be damaged, and the screw will not be properly tightened.<br />
② If the terminal screws are tightened too hard, screws might be<br />
damaged.<br />
3. Do not connect wires <strong>of</strong> different gauge to the same<br />
grounding terminal. Loose connection may deteriorate<br />
protection.<br />
4. Outside <strong>of</strong> the unit, keep proper separation between<br />
transmission and power sup<strong>pl</strong>y wiring. The equipment<br />
may malfunction if subjected to electrical (external)<br />
noise.<br />
5. Never connect power sup<strong>pl</strong>y wiring to the terminal<br />
block for remote controller wiring. A mistake <strong>of</strong> the sort<br />
could damage the entire system.<br />
6. Use only specified wire and tightly connect wires to terminals.<br />
Be careful wires do not <strong>pl</strong>ace external stress on<br />
terminals. Keep wiring in neat order and so as not to<br />
obstruct other equipment such as popping open the<br />
electric parts box cover. Make sure the cover closes<br />
tight. Incom<strong>pl</strong>ete connections could result in overheating,<br />
and in worse case, electric shock or fire.<br />
340 Installation <strong>of</strong> indoor unit<br />
NOTE<br />
Round crimp-style terminal<br />
Attach insulation sleeve<br />
Electric wire<br />
Connect wires <strong>of</strong> the same gauge to both sides
5CSL0-06B Ceiling concealed duct (High static)<br />
3.4 Ceiling concealed duct (High static)<br />
• Please read the instruction sheets com<strong>pl</strong>etely before installing the product.<br />
• When the power cord is damaged, re<strong>pl</strong>acement work shall be performed by authorized personnel only.<br />
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.<br />
3.4.1 Accessories<br />
Check whether the following accessories are included with your unit.<br />
1) Standard accessories<br />
Name<br />
Quantity<br />
Clamp metal<br />
1 EA<br />
Air Sup<strong>pl</strong>y<br />
Drain hose<br />
1 EA<br />
Air sup<strong>pl</strong>y vents<br />
Air return vents<br />
Insulation for<br />
fitting<br />
Shape for gas pipe<br />
Remote controller<br />
1 set 6 EA 1 set<br />
for liquid pipe<br />
Air return<br />
Clamp<br />
Air filters<br />
(Optional)<br />
Remote controller<br />
Screws for<br />
duct flanges<br />
Air filter<br />
Can be installed<br />
inside return grill.<br />
(Other)<br />
• Owner's manual<br />
• Installation manual<br />
• Washers(8 pcs.)<br />
Installation <strong>of</strong> indoor unit 341
Ceiling concealed duct (High static)<br />
3.4.2 Selection <strong>of</strong> the best location<br />
Install the air conditioner in the location that satisfies the following<br />
conditions.<br />
1. The <strong>pl</strong>ace shall easily bear a load <strong>of</strong> the indoor unit.<br />
2. The <strong>pl</strong>ace should have enough area for inspection as shown<br />
in figure.<br />
3. The <strong>pl</strong>ace where the unit shall be leveled.<br />
4. The <strong>pl</strong>ace shall allow easy water drainage.(Suitable dimension<br />
“H” is necessary to get a slope to drain as figure.)<br />
5. The <strong>pl</strong>ace shall easily connect with the outdoor unit.<br />
6. The <strong>pl</strong>ace where the unit is not affected by an electrical<br />
noise.<br />
7. The <strong>pl</strong>ace where air circulation in the room will be good .<br />
8. There should not be any heat source or steam near the unit.<br />
3.4.3 Ceiling dimension, also hanging<br />
bolt location and service space<br />
1) Select an installation site where the following conditions<br />
are fulfilled and also that meets with your<br />
customer's approval.<br />
• If supporting structural members are not strong enough<br />
to take the units weight, the unit could fall out <strong>of</strong> <strong>pl</strong>ace<br />
and cause serious injury.<br />
• Where sufficient clearance <strong>of</strong> maintenance and service<br />
can be ensured.<br />
• Where optimum air distribution can be ensured.<br />
• Where nothing blocks the air passage.<br />
• Where condensate can be properly drained.<br />
• Where piping between indoor and outdoor units is possible<br />
within the allowable limit (Refer to the installation<br />
manual <strong>of</strong> the outdoor unit.)<br />
• Keep the indoor and outdoor units, power cable and<br />
transmission wiring, at least 1 m from TVs and radios,<br />
to prevent distorted pictures and static.(Depending on<br />
the type and source <strong>of</strong> the electrical waves, static may<br />
be heard even when more than 1 m away.)<br />
B<br />
A C<br />
Model A B C<br />
ABNH186HLAD [UB18 NHD]<br />
ABNH246HLAD [UB24 NHD]<br />
880 260 450<br />
ABNH306GLAD [UB30 NGD]<br />
ABNH366GLAD [UB36 NGD]<br />
ABNH426RLAD [UB42 NRD]<br />
1,180 298 450<br />
ABNH486RLAD [UB48 NRD]<br />
ABNH606RLAD [UB60 NRD]<br />
1,229 589 379<br />
Min. 460<br />
(Service space)<br />
30mm or more<br />
30mm or more<br />
5CSL0-06B<br />
2) Relative positions <strong>of</strong> indoor unit, suspension bolt<br />
and inspection hatch size<br />
3) Install a canvass duct to the air discharge outlet<br />
and air inlet so that vibration from the machine<br />
body is not transmitted to the duct or ceiling. You<br />
should also ap<strong>pl</strong>y acoustic (insulation material) to<br />
the inside <strong>of</strong> the duct, and vibration insulation<br />
rubber to the suspension bolts.<br />
4) Install suspension bolts.<br />
(Use bolts <strong>of</strong> 10 mm diameter.)<br />
• Install the equipment where supporting structures are<br />
strong enough to bear the equipment's weight. Use<br />
embedded inserts or anchor bolts with new buildings<br />
and hole-in-anchors with old buildings.<br />
342 Installation <strong>of</strong> indoor unit<br />
NOTE<br />
a<br />
If the service panel is at the top <strong>of</strong> the unit, then provide<br />
sufficient service clearance as per convenience.<br />
932<br />
882<br />
1232<br />
1182<br />
Model A<br />
ABNH186HLAD [UB18 NHD]<br />
ABNH246HLAD [UB24 NHD]<br />
900<br />
ABNH306GLAD [UB30 NGD]<br />
ABNH366GLAD [UB36 NGD]<br />
ABNH426RLAD [UB42 NRD]<br />
1200<br />
ABNH486RLAD [UB48 NRD]<br />
ABNH606RLAD [UB60 NRD]<br />
1320<br />
120<br />
Inspection<br />
hatch 600 x 600<br />
150<br />
740<br />
740<br />
Inspection<br />
hatch 600 x 600
5CSL0-06B Ceiling concealed duct (High static)<br />
3.4.4 Position <strong>of</strong> suspension bolt<br />
① Install the unit leaning to a drainage hole side as given in<br />
the figure above for easy water drainage.<br />
② A <strong>pl</strong>ace where the unit will be leveled and that can support<br />
the weight <strong>of</strong> the unit.<br />
③ A <strong>pl</strong>ace where the unit can withstand its vibration.<br />
④ A <strong>pl</strong>ace where service can be easily performed.<br />
⑤ Select and mark the position for fixing bolts.<br />
⑥ Drill the hole for set anchor on the face <strong>of</strong> ceiling.<br />
CAUTION<br />
M10 Nut x 4<br />
M10 SP. washer x 4<br />
M10 washer<br />
(Local<br />
sup<strong>pl</strong>y)<br />
x 4<br />
M10 washer x 4<br />
M10 SP. washer x 4<br />
M10 Nut<br />
(Local<br />
sup<strong>pl</strong>y)<br />
x 4<br />
• Tighten the nut and bolt to prevent unit from<br />
falling.<br />
⑦ Insert the set anchor and washer on the suspension bolts<br />
for locking the suspension bolts on the ceiling.<br />
⑧ Mount the suspension bolts to the set anchor firmly.<br />
⑨ Secure the installation <strong>pl</strong>ates on the suspension bolts<br />
(adjust level roughly) using nuts, washers and spring<br />
washers.<br />
Old building New building<br />
1 Set anchor<br />
2 Plate washer<br />
3 Spring washer<br />
4 Nut<br />
5 Suspension<br />
bolts<br />
Installation <strong>of</strong> indoor unit 343
Ceiling concealed duct (High static)<br />
3.4.5 Connection pipes to the indoor<br />
unit<br />
1) Refrigerant piping work<br />
<strong>pl</strong>ease refer “REFRIGERANT PIPING WORK”.<br />
2) Piping insulation<br />
① Perform heat insulation work com<strong>pl</strong>etely on both gas and<br />
the liquid pipe. Because improper insulation will result<br />
due condensate formation over pipe.<br />
② Use the heat insulation material for the refrigerant piping<br />
which has an excellent heat resistance (over 120°C).<br />
③ Precautions in high humidity circumstance.<br />
④ Refer to the insulation works.<br />
CAUTION<br />
Liquid pipe<br />
Union for gas pipe<br />
Clamp for insulation<br />
(Local sup<strong>pl</strong>y)<br />
Insulation<br />
(Local sup<strong>pl</strong>y)<br />
Refrigerant pipe and thermal<br />
insulation(Local sup<strong>pl</strong>y)<br />
Thermal insulation for refrigerant pipe<br />
(Local sup<strong>pl</strong>y) Thermal insulation for<br />
piping(Local sup<strong>pl</strong>y)<br />
Overlap with<br />
insulation<br />
Make sure that there is no clearance here.<br />
• Make sure to insulate any field piping all the way to the<br />
piping connection inside the unit. Any exposed piping<br />
may cause condensation or burns if touched.<br />
3) Indoor unit drain piping<br />
5CSL0-06B<br />
① During drain piping connection, be careful not to exert<br />
extra force on the drain port on the indoor unit.<br />
② The outside diameter <strong>of</strong> the drain connection on the<br />
indoor unit is 32mm.<br />
Piping material: Polyvinyl chloride pipe inner diameter<br />
Ø 25mm and pipe fitting<br />
CAUTION<br />
1. Decline Installation <strong>of</strong> indoor unit is very important for<br />
the drain <strong>of</strong> the duct type air conditioner.<br />
2. Minimum thickness <strong>of</strong> the insulation for the connecting<br />
pipe should be 5mm.<br />
4) Caution for gradient <strong>of</strong> unit and drain piping<br />
- Without drain pump<br />
① Always lay the drain with downward inclination (1/50 to<br />
1/100).<br />
Prevent any upward flow or reverse flow in any part.<br />
② 10mm or thicker formed thermal insulation shall always<br />
be provided for the drain pipe.<br />
Approx 2~3mm<br />
Attached drain hose<br />
Downward 1/50~1/100 or more<br />
Bottom <strong>of</strong> unit<br />
※ U-trap is not required for low static model in which the<br />
external static pressure is below 50 pa(5mm Aq)<br />
344 Installation <strong>of</strong> indoor unit<br />
50mm<br />
or more<br />
50mm<br />
or more
5CSL0-06B Ceiling concealed duct (High static)<br />
- With drain pump<br />
① Possible drain head is upto 700mm.<br />
② Keep the drain pipe downward stope upto 1/50~1/100.<br />
Prevent any upward flow or reverse flow in any part.<br />
③ 10mm or thicker insulation should be provided for the<br />
drain pipe.<br />
Unit<br />
Drain Pipe<br />
Drain Pump<br />
3) Checking the drain<br />
1) Checking the drain<br />
① Remove the air filter.<br />
MAX 700mm<br />
Elbow<br />
Drain pump<br />
1/50~1/100<br />
Thermal insulattion<br />
(Local sup<strong>pl</strong>y)<br />
Drain pipe<br />
(Local sup<strong>pl</strong>y)<br />
2. Check the drain.<br />
① Poor eough water on the drain pan.<br />
② Ensure that water flows through the drain pipe from<br />
indoor unit without any leakage.<br />
3.4.6 Electric wiring work<br />
1) General instructions<br />
① All field sup<strong>pl</strong>ied parts and materials, electric works must<br />
conform to local codes.<br />
Use copper wire only.<br />
② Follow the "WIRING DIAGRAM” attached to the unit<br />
body to wire the outdoor unit, indoor units and the remote<br />
controller.<br />
③ All wiring must be performed by an authorized electrician.<br />
④ This system consists <strong>of</strong> multi<strong>pl</strong>e indoor units. Mark each<br />
indoor unit as unit A, unit B..., and be sure the terminal<br />
board wiring to the outdoor unit and indoor unit are properly<br />
matched. If wiring and piping between the outdoor<br />
unit and an indoor unit are mismatched, the system may<br />
cause a malfunction.<br />
⑤ A circuit breaker capable <strong>of</strong> shutting down the power<br />
sup<strong>pl</strong>y to the entire system must be installed.<br />
Installation <strong>of</strong> indoor unit 345
Ceiling concealed duct (High static)<br />
2) Wiring connection<br />
Connect the wires to the terminals on the control board individually<br />
according to the outdoor unit connection.<br />
① Ensure that the color <strong>of</strong> the wires <strong>of</strong> outdoor unit and the<br />
terminal No. are the same as those <strong>of</strong> indoor unit respectively<br />
30k/36k/42k/48k/60kBtu/h.<br />
② If the sup<strong>pl</strong>y cord is damaged, it must be re<strong>pl</strong>aced by a<br />
special cord or assembly availible from the manufacturer<br />
<strong>of</strong> its service agent.<br />
WARNING<br />
Terminal block in indoor<br />
1(L) 2(N) 3 4<br />
Connected to outdoor unit<br />
1(L) 2(N)<br />
POWER INPUT<br />
• Make sure that the screws <strong>of</strong> the terminal are fixed tightly.<br />
CAUTION<br />
• Make sure to attach the sealing material or (field sup<strong>pl</strong>ied)<br />
to hole <strong>of</strong> wiring to prevent the infiltration <strong>of</strong> foreign<br />
particle from outside. Otherwise a short-circuit may<br />
occur inside the electric parts box<br />
• When clamping the wires, be sure no pressure is ap<strong>pl</strong>ied<br />
to the wire connections by using the included clamping<br />
material to make appropriate clamps. Also, when wiring,<br />
make sure the cover on the electric parts box fits snugly<br />
by arranging the wires neatly and attaching the electric<br />
parts box cover firmly. When attaching the electric parts<br />
box cover, make sure no wires get caught in the edges.<br />
Pass wiring through the holes to prevent damage to<br />
them.<br />
• Make sure the remote controller wiring, the wiring<br />
between the units, and other electrical wiring do not pass<br />
through the same locations outside <strong>of</strong> the unit, separating<br />
them properly, otherwise electrical noise (external<br />
static) could cause product malfunction.<br />
5CSL0-06B<br />
1. Use round crimp-style terminals for connecting<br />
wires to the power sup<strong>pl</strong>y terminal block. If<br />
unavailable, observe the following points when<br />
wiring.<br />
① Do not connect wires <strong>of</strong> different gauge to the same<br />
power sup<strong>pl</strong>y terminal.<br />
② Use the specified electric wire. Connect the wire securely<br />
to the terminal. Lock the wire down without ap<strong>pl</strong>ying<br />
excessive force to the terminal.<br />
2 Tightening torque for the terminal screws.<br />
① Use the correct screwdriver for tightening the terminal<br />
screws. If the blade <strong>of</strong> screwdriver is too small, the head<br />
<strong>of</strong> the screw might be damaged, and the screw will not<br />
be properly tightened.<br />
② If the terminal screws are tightened too hard, screws<br />
might be damaged.<br />
3. Do not connect wires <strong>of</strong> different gauge to the<br />
same grounding terminal. Loose connection may<br />
deteriorate protection.<br />
4. Outside <strong>of</strong> the unit, keep proper separation<br />
between transmission and power sup<strong>pl</strong>y wiring.<br />
The equipment may malfunction if subjected to<br />
electrical (external) noise.<br />
5. Never connect power sup<strong>pl</strong>y wiring to the terminal<br />
block for remote controller wiring. A mistake <strong>of</strong><br />
the sort could damage the entire system.<br />
6. Use only specified wire and tightly connect wires<br />
to terminals. Be careful wires do not <strong>pl</strong>ace external<br />
stress on terminals. Keep wiring in neat order<br />
and so as not to obstruct other equipment such as<br />
popping open the electric parts box cover. Make<br />
sure the cover closes tight. Incom<strong>pl</strong>ete connections<br />
could result in overheating, and in worse<br />
case, electric shock or fire.<br />
346 Installation <strong>of</strong> indoor unit<br />
NOTE<br />
Round crimp-style terminal<br />
Attach insulation sleeve<br />
Electric wire<br />
Connect wires <strong>of</strong> the same gauge to both sides
5CSL0-06B Console (Floor stand)<br />
3.5 Console (Floor stand)<br />
3.5.1 Accessories<br />
Check whether the following accessories are included with your unit.<br />
1) Standard accessories<br />
Name<br />
Quantity<br />
Shape<br />
❈ You should purchase the installation parts.<br />
Install <strong>pl</strong>ate<br />
1 EA<br />
Drain hose<br />
1 EA<br />
Remote controller<br />
& holder<br />
Battery<br />
Sleeve<br />
Bushing-Sleeve<br />
Putty(Gum Type Sealant)<br />
Bend the pipe as closely<br />
on the wall as possible,<br />
but be careful that it<br />
doesn't break.<br />
Allergy filter<br />
Screw<br />
1 set 1 EA 1 set<br />
• Fixing Screw for<br />
R. Controller<br />
Holder<br />
• Fixing Screw for<br />
Install Plate 4 x<br />
25mm<br />
• Wood Screw for<br />
Indoor fixation<br />
(Other)<br />
• Owner's<br />
manual<br />
• Installation<br />
manual<br />
• Washers<br />
(8 pcs.)<br />
Installation <strong>of</strong> indoor unit 347
Console (Floor stand)<br />
3.5.2 Selection <strong>of</strong> the best location<br />
Install the air conditioner in the location that satisfies the following<br />
conditions.<br />
1.There should not be any heat or steam near the unit.<br />
2. Select a <strong>pl</strong>ace where there are no obstacles around <strong>of</strong> the<br />
unit.<br />
3. Make sure that condensation drainage can be conveniently<br />
routed away.<br />
4. Do not install near a doorway.<br />
5. Ensure that the interval between a wall and the left (or right)<br />
<strong>of</strong> the unit is more than 300mm.<br />
6. Use a metal detector to locate studs to prevent unnecessary<br />
damage to the wall.<br />
7. It is away from electronic ignition type fluorescent lamps as<br />
they may shorten the remote controller range.<br />
8. Please check at least 1m away from television or radio.(It<br />
cause interference with the picture or sount)<br />
NOTE<br />
• Before choosing the installation site, <strong>pl</strong>ease obtain user<br />
approval<br />
• If the unit is installed below a window,check the interference<br />
<strong>of</strong> window curtain.(more than 300mm)<br />
• Because <strong>of</strong> dust problem, If the bottm height "H" is less<br />
than 100mm, Keep the bottom vane close not to make<br />
dust from the bottom.<br />
More than<br />
300<br />
250 or less<br />
from the Floor<br />
More than 300<br />
More than<br />
300<br />
(Unit : mm)<br />
3.5.3 Installation<br />
1) Preparation / Removing front panel<br />
5CSL0-06B<br />
① Open the front grille by pulling forward<br />
② Then pull out the link <strong>of</strong> grille from groove in front panel.<br />
③ Then pull out 2 hinges <strong>of</strong> grille from grooves in front<br />
panel.<br />
④ Then remove 4 screws, dismount the front panel while<br />
pulling it forward.<br />
2) Preparation / For Moldings , Side Piping,<br />
and Concealed Installation<br />
① For Moldings<br />
• Remove the slit portions on the Rear Panel.<br />
Remove<br />
348 Installation <strong>of</strong> indoor unit
5CSL0-06B Console (Floor stand)<br />
② For Concealed Installation<br />
• Remove the 6 screws.<br />
• Remove the Upper Deco cover.<br />
• Remove the Side Deco covers.<br />
Side Deco cover<br />
③ For Side Piping (Reference ②)<br />
• Remove the Deco Covers.<br />
• Remove the slit portions<br />
• Assemble the Deco Covers.<br />
3) Refrigerant Piping<br />
① The location <strong>of</strong> hole is different depending on which side<br />
<strong>of</strong> the pipe is taken out.<br />
② Drill a hole (Ø70mm)in the point indicated by symbol<br />
in the illustration as below<br />
45<br />
Upper Deco cover<br />
Left bottom piping 90 75 Right bottom piping<br />
Right back piping<br />
50<br />
Left/right piping<br />
40<br />
Wall<br />
60<br />
90 75<br />
Left back piping Right back piping<br />
45<br />
45<br />
(Unit : mm)<br />
The suggested shortage pipe length is 5m,in order to avoid<br />
noise from the outdoor unit and vibration.<br />
4) Drill a Hole in the wall<br />
• Drill the piping hole with a ø70mm hole core drill. Drill<br />
the piping hole at either the right or the left with the<br />
hole slightly slanted to the outdoor side.<br />
5) Drain piping<br />
① The Outer diameter <strong>of</strong> Drain Hose (which is sup<strong>pl</strong>ied with<br />
indoor unit) is 17mm at connecting end,600mm long.<br />
② Use commercial rigid PVC pipe for extension.<br />
③ Insulate the indoor drain pipe with 10mm or more <strong>of</strong> insulation<br />
material to prevent condensation.<br />
Installation <strong>of</strong> indoor unit 349<br />
NOTE<br />
NOTE<br />
Indoor<br />
[Unit : mm]<br />
103<br />
Water<br />
leakage<br />
Water<br />
leakage<br />
600<br />
Do not raise<br />
WALL<br />
87<br />
Tip <strong>of</strong> drain hose<br />
dipped in water<br />
Ditch<br />
Water<br />
leakage<br />
5-7mm<br />
Outdoor<br />
(3/16"~5/16")<br />
Accumulated<br />
drain water<br />
Air<br />
Waving<br />
Ø17<br />
Less than<br />
50mm gap<br />
The drain pipe should be inclined downward so that water<br />
will flow smoothly without any accumulation.
Console (Floor stand)<br />
6) Installing Indoor unit<br />
① Installation on the Floor.<br />
• Fix up using 6 screws for floor installation.<br />
② Installation on the Wall<br />
• Fix up the installation <strong>pl</strong>ate using 5 screws and the<br />
indoor unit using 4 screws.<br />
• The installation <strong>pl</strong>ate should be fixed on a wall which<br />
4 screw (M*25L)<br />
6 screw (M*25L)<br />
30.5<br />
210<br />
180<br />
140<br />
170<br />
Installation Plate<br />
Molding<br />
can support the weight <strong>of</strong> the indoor unit.<br />
64<br />
(700)<br />
647<br />
159<br />
30.5<br />
26<br />
140<br />
170<br />
160<br />
(600)<br />
574<br />
(Unit : mm)<br />
③ Half concealed installation.<br />
• Make a wall hole <strong>of</strong> the size shown Fig-1.<br />
5CSL0-06B<br />
• Installation <strong>of</strong> sup<strong>pl</strong>emental <strong>pl</strong>ate for attaching main unit<br />
The rear <strong>of</strong> the unit can be fixed with screws at the points<br />
shown in the Fig-2. Be sure to install the sup<strong>pl</strong>emental<br />
<strong>pl</strong>ate in accordance with the depth <strong>of</strong> the inner wall.<br />
• Pipeing Hole<br />
350 Installation <strong>of</strong> indoor unit<br />
45<br />
Wall<br />
Sup<strong>pl</strong>emental <strong>pl</strong>ate<br />
(Field sup<strong>pl</strong>y)<br />
200<br />
150<br />
Hole<br />
670<br />
200<br />
150<br />
585<br />
<br />
95 Sup<strong>pl</strong>emental <strong>pl</strong>ate<br />
(Field sup<strong>pl</strong>y)<br />
1) Normal concealed 2) Deep concealed<br />
50<br />
140<br />
170<br />
75<br />
647<br />
<br />
(Unit : mm)<br />
140<br />
170<br />
Left bottom pipng Right bottom pipng<br />
75<br />
35<br />
(Unit : mm)<br />
Wall
5CSL0-06B Console (Floor stand)<br />
• Remove the Deco Covers and Fixing Indoor Unit<br />
Remove the Deco Covers.(Reference ② <strong>of</strong> 2))<br />
Insert the Indoor Unit to the Wall hole.<br />
Secure using 6 screws. (shown the illustration)<br />
NOTE<br />
Left pipng<br />
Wall<br />
50<br />
Check the horizon <strong>of</strong> Indoor unit with the wall. Please use<br />
the Leveler on the drain pan guide.<br />
45<br />
(Unit : mm)<br />
Leveler Drain pan<br />
Less than 5mm<br />
Less than 5mm<br />
Less than 5mm<br />
Installation <strong>of</strong> indoor unit 351
Console (Floor stand)<br />
3.5.4 Connection pipes to the indoor<br />
unit<br />
1) Refrigerant piping work<br />
<strong>pl</strong>ease refer “REFRIGERANT PIPING WORK”.<br />
2) Piping connection<br />
① When you connect the refrigerant pipe, it is easier that<br />
connect the gas pipe first.<br />
② The direction <strong>of</strong> piping is available for six way as below<br />
illustration.<br />
③ Remove the pillars <strong>of</strong> side covers and rear panel what<br />
you need to cut.<br />
3<br />
2<br />
CAUTION<br />
1<br />
4<br />
5<br />
More than<br />
5mm<br />
• If the drain hose is routed inside the room insulate<br />
the hose with an insulation material* so that dripping<br />
from sweating (condensation) will not damage<br />
furniture or floors.<br />
* Foamed polyethylene or equivalent is recommended.<br />
6<br />
Drain hose<br />
Connecting pipe<br />
5CSL0-06B<br />
3.5.5 Wiring connection<br />
1) Loosen No 1,2 screws <strong>of</strong> control box<br />
cover.<br />
2) Connect the cable followed by circuit diagram.<br />
3) If it is needed for indoor units setting,<br />
loosen No.3 screw and lift up the PCB.<br />
(option: usage <strong>of</strong> bottom vanes, limit<br />
angle <strong>of</strong> top vane)<br />
352 Installation <strong>of</strong> indoor unit<br />
1<br />
2<br />
3<br />
Tape<br />
Connecting<br />
cable<br />
Terminal Block <strong>of</strong> Indoor Unit<br />
1(L) 2(N) 3<br />
Dip S/W Description S/W OFF S/W ON<br />
S/W 5 Install scene Exposed Half<br />
Concealed<br />
S/W 7 Vane Top+Bottom Top vane<br />
vane only
5CSL0-06B Console (Floor stand)<br />
CAUTION<br />
The connecting cable connected to the indoor and<br />
outdoor unit should be com<strong>pl</strong>ied with the following<br />
specifications (Rubber insulation, type H05RN-F<br />
approved by HAR or SAA).<br />
If the sup<strong>pl</strong>y cord is damaged, it must be re<strong>pl</strong>aced<br />
by a special cord or assembly available from the<br />
manufacturer <strong>of</strong> its service agent.<br />
WARNING<br />
GN/YL<br />
4) Electrical wiring<br />
20mm<br />
NORMAL<br />
CROSS-SECTIONAL<br />
AREA 0.75mm 2 (9k12k/18k Btu/h)<br />
Make sure that the screws <strong>of</strong> the terminal are free<br />
from looseness.<br />
① All wiring must com<strong>pl</strong>y with LOCAL REGULATIONS.<br />
② Select a power source that is capable <strong>of</strong> sup<strong>pl</strong>ying the<br />
current required by the air conditioner.<br />
③ Feed the power source to the unit via a distribution<br />
switch board designed for this purpose.<br />
④ The terminal screws inside the control box may be loose<br />
due to vibration during transport.<br />
Check the screws for loose connection.<br />
(Running the air conditioner with loose connection can<br />
overload and damage electrical components.)<br />
⑤ Always ground the air conditioner with a grounding wire<br />
and connector to meet the LOCAL REGULATION.<br />
CAUTION<br />
• The circuit diagram is not subject to change without notice.<br />
• Be sure to connect wires according to the wiring diagram.<br />
• Connect the wires firmly, so that not to be pulled out easily.<br />
• Connect the wires according to color codes by referring the<br />
wiring diagram.<br />
Main power source<br />
Air<br />
Conditioner<br />
3.5.6 Installation front panel<br />
Circuit Breaker<br />
① Fit the Front Panel onto the indoor unit and push the<br />
upper area that are marked with arrows<br />
② Check the air sensor and install the 4 screws<br />
③ Then assemble the front grille and put the hinges<br />
④ Close the grille.<br />
Installation <strong>of</strong> indoor unit 353
Console (Floor stand)<br />
5CSL0-06B<br />
354 Installation <strong>of</strong> indoor unit
5CSL0-06B<br />
4. Installation <strong>of</strong> outdoor unit<br />
4.1 Safety Precautions<br />
Please strictly follow the instructions given in the Installation<br />
manual .Improper installation by ignoring the instructions<br />
can lead to damage to life and property.<br />
Make sure to read the following safety instructions very<br />
carefully and throughly .<br />
WARNING : This symbol indicates the possibility <strong>of</strong><br />
death or serious injury.<br />
CAUTION : This symbol indicates the possibility <strong>of</strong><br />
injury or damage to properties.<br />
■ The meanings <strong>of</strong> the symbols used in this manual are as<br />
shown below.<br />
: Be sure not to do.<br />
: Be sure to follow the instruction.<br />
WARNING<br />
Do not use a defective or underrated circuit breaker.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Do not use a multi consent. Always use this ap<strong>pl</strong>iance<br />
on a dedicated circuit and breaker.<br />
• Otherwise it can cause electric shock or fire.<br />
For electrical work, contact the dealer, seller, a qualified<br />
electrician, or an authorized service center. Do not disassemble<br />
or repair the product by yourself.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Always ground the product as per the wiring diagram.<br />
Do not connect the ground wire to gas or water pipes<br />
lightening rod or telephone ground wire.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
Install the panel and the cover <strong>of</strong> control box securely.<br />
• There is risk <strong>of</strong> fire or electric shock due to dust , water<br />
etc.<br />
Use the correctly rated breaker or fuse.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
If the power cable or cord has scratches or skin peeled<br />
<strong>of</strong>f or deterioted then immediately re<strong>pl</strong>ace it.<br />
• There is risk <strong>of</strong> fire or electric shock.<br />
For installation, removal or reinstall, always contact the<br />
dealer or an authorized service center.<br />
• There is risk <strong>of</strong> fire, electric shock, ex<strong>pl</strong>osion, or injury.<br />
Do not install the product on a defective foundation. Be<br />
sure that the installation area does not deteriorate with<br />
age.<br />
• If the foundation collapses, the air conditioner could fall<br />
with it, causing property damage, product failure, and personal<br />
injury.<br />
Safety Precautions<br />
Never install the outdoor unit at a <strong>pl</strong>ace from where it<br />
can fall down.<br />
• The falling outdoor unit can cause damage or injury or<br />
even death <strong>of</strong> a person and also damage or malfunctioning<br />
<strong>of</strong> the product itself.<br />
When the product is soaked (flooded or submerged) in<br />
water, contact an authorized service center for repair<br />
before using it again.<br />
• There is risk <strong>of</strong> fire or eletric shock.<br />
In outdoor units the the step up capacitor sup<strong>pl</strong>ies high<br />
voltage electricity to the electrical components. Be sure<br />
to discharge the capacitor com<strong>pl</strong>etely before conducting<br />
the repair work.<br />
• An charged capacitor can cause electrical shock.<br />
Be sure to use only those parts which are listed in the<br />
svc parts list. Never attempt to modify the equipment.<br />
• The use <strong>of</strong> inappropriate parts can cause an electrical<br />
shock, excessive heat generation or fire.<br />
Indoor/outdoor wiring connections must be secured<br />
tightly and the cable should be routed properly so that<br />
there is no force pulling the cable at the connection<br />
terminals.<br />
• Improper or loose connections can cause excessive heat<br />
heat generation or fire.<br />
Safely dispose <strong>of</strong>f the packing materials.<br />
• Things like screws, nails, batteries, broken things etc after<br />
installation or svc can cause injury to small kids. Tear<br />
away and throw away the <strong>pl</strong>astic packaging bags so that<br />
children will not <strong>pl</strong>ay with them.<br />
Make sure to check that the power cable <strong>pl</strong>ug is not<br />
dirty, loose or broken, then only insert the <strong>pl</strong>ug com<strong>pl</strong>etely.<br />
• Dirty,loose or broken power <strong>pl</strong>ug can cause electric shock<br />
or fire.<br />
During svc be sure to check the refrigerant to the used.<br />
• Incorrect refrigerant used can prevent the normal operation<br />
<strong>of</strong> the unit.<br />
When installing the unit, use the installation kit provided<br />
with the product.<br />
• Otherwise the unit may fall and cause severe injury .<br />
Do not touch, operate, or repair the product with wet<br />
hands.<br />
• There is risk <strong>of</strong> electric shock or fire.<br />
Do not <strong>pl</strong>ace a heater or other ap<strong>pl</strong>iances near the<br />
power cable.<br />
• There is risk <strong>of</strong> fire and electric shock.<br />
Do not allow water to run into electric parts. Install the<br />
unit away from water sources<br />
• There is risk <strong>of</strong> fire, failure <strong>of</strong> the product, or electric shock.<br />
Do not store or use or even allow flammable gas or<br />
combustibles near the product.<br />
• There is risk <strong>of</strong> fire or failure <strong>of</strong> product.<br />
Installation <strong>of</strong> outdoor unit 355
Safety Precautions 5CSL0-06B<br />
If strange sounds, smell or smoke comes from the<br />
product, immediately turn the breaker <strong>of</strong>f or disconnect<br />
the power sup<strong>pl</strong>y cable.<br />
• There is risk <strong>of</strong> electric shock or fire.<br />
Do not open the front grill <strong>of</strong> the product during operation.<br />
(Do not touch the electrostatic filter, if the unit is<br />
so equipped.)<br />
• There is risk <strong>of</strong> physical injury, electric shock, or product<br />
failure.<br />
Turn the main power <strong>of</strong>f when cleaning or repairing the<br />
product.<br />
• There is risk <strong>of</strong> electric shock.<br />
When the product is not to be used for a long time, turn<br />
<strong>of</strong>f the circuit breaker.<br />
• There is risk <strong>of</strong> product damage or failure, or unintended<br />
operation.<br />
Take care to ensure that nobody especially kids could<br />
step on or fall onto the outdoor unit.<br />
• This could result in personal injury and product damage.<br />
CAUTION<br />
Use two or more peo<strong>pl</strong>e to lift and transport the product.<br />
• Avoid personal injury.<br />
Do not install the product where it will be exposed to<br />
sea wind (salt spray) directly.<br />
• It may cause corrosion on the product. Corrosion, particularly<br />
on the condenser and evaporator fins, could cause<br />
product malfunction or inefficient operation.<br />
Keep level even when installing the product.<br />
• To avoid vibration or noise.<br />
Do not install the product where the noise or hot air<br />
from the outdoor unit could damage or disturb the<br />
neighborhoods.<br />
• It may cause a problem for your neighbors and hence dispute.<br />
Always check for gas (refrigerant) leakage after installation<br />
or repair <strong>of</strong> product.<br />
• Low refrigerant levels may cause failure <strong>of</strong> product.<br />
Do not block the inlet or outlet <strong>of</strong> air flow.<br />
• It may cause product failure.<br />
Do not step on or put anyting on the product.<br />
• There is risk <strong>of</strong> personal injury and failure <strong>of</strong> product.<br />
Do not insert hands or other objects through the air<br />
inlet or outlet while the product is operating.<br />
• There are sharp and moving parts that could cause personal<br />
injury.<br />
Be cautious when unpacking and installing the product.<br />
• Sharp edges could cause injury. Be especially careful <strong>of</strong><br />
the case edges and the fins on the condenser and evaporator.<br />
If the refrigerant gas leaks during the repair, do not<br />
touch the leaking refrigerant gas.<br />
• The refrigernat gas can cause frostbite (cold burn).<br />
Do not tilt the unit when removing or uninstalling it.<br />
• The condensed water inside can cause spill and wet the<br />
furniture and the floor.<br />
Do not mix air or gas other than the specified refrigerant<br />
used in the system.<br />
• If air enters the refrigerant system, an excessively high<br />
pressure results, causing equipment damage or injury.<br />
If the refrigerant gas leaks during the installation or<br />
operation ventilate the area immediately.<br />
• Otherwise it can be harmfull for your health.<br />
Do not expose your skin or kids or <strong>pl</strong>ants to the cool or<br />
hot air draft.<br />
• This could harm to your health.<br />
Use a firm stool or ladder when cleaning, maintaining<br />
or repairing the product at an height.<br />
• Be careful and avoid personal injury.<br />
Dismantling the unit , treatment <strong>of</strong> the refrigerant oil, oil<br />
and eventual parts should be done in accordance with<br />
local and national standards.<br />
4.1.1 Points for ex<strong>pl</strong>anation about<br />
operations<br />
The items with WARNING and CAUTION marks in the operation<br />
manual are the items pertaining to possibillties for<br />
bodily injury and material damage in addition to the general<br />
usage <strong>of</strong> the product. Accordingly, it is necessary that you<br />
make a full ex<strong>pl</strong>anation about the described contents and<br />
also ask your customers to read the operation manual.<br />
4.1.2 Note to the installer<br />
Be sure to instruct customers how to properly operate the<br />
unit (especially cleaning filters, operating different functions,<br />
and adjusting the temperature) by having them carry out<br />
operations themselves while looking at the manual.<br />
4.1.3 Selecting installation site for<br />
outdoor units<br />
Select an installation site where the following conditions are<br />
fulfilled and that meets with your customer's approval.<br />
1. Location strong enough to bear the weight <strong>of</strong> the unit.<br />
2. Location accessible and having enough clearance for<br />
inspection and service in the future.<br />
3. Location allowing easy condensate drainage suitable gradient<br />
<strong>of</strong> the unit and the drain pipe.<br />
4. Piping between the indoor and outdoor unit is possible<br />
within the allowable limits.<br />
356 Installation <strong>of</strong> outdoor unit
5CSL0-06B<br />
5. Location free from electrical noise.<br />
6. Location allowing optimum air distribution without any<br />
blocking to air flow.<br />
7. Location having no risk <strong>of</strong> flammable gas leakage.<br />
8. Location free from mineral oil mist or an oil spray or vapor<br />
eg in kitchen .It could result in leakage .<br />
9. Location free from corrosive gases such as sulphurous<br />
acid gas because it corrodes the copper pipes or soldered<br />
parts resulting in leakage .<br />
10. Location free from any machinery emitting electromagnetic<br />
waves which may disturb the control system thus<br />
causing malfunction <strong>of</strong> the unit .<br />
11. Location free from flammable gases , carbon fibre , or<br />
ignitable dust suspensions in the air or where volatile<br />
flames are handled like gasoline or thinner. Operating in<br />
such conditions may result in fire.<br />
Safety Precautions<br />
12. Install the indoor and outdoor units, power sup<strong>pl</strong>y wiring<br />
and connecting wires at least 1m. away from televisions<br />
or radios in order to prevent image interference or noise.<br />
(Depending on the radio waves, a distance <strong>of</strong> 1m. may<br />
not be sufficient enough to eliminate the noise.)<br />
13. Consider whether the <strong>pl</strong>ace where the unit will be<br />
installed can support the full weight <strong>of</strong> the unit, and reinforce<br />
it with boards and beams, etc. if needed before<br />
proceeding with the installation. Also, reinforce the <strong>pl</strong>ace<br />
to prevent vibration and noise before installing. (The<br />
installation pitch can be found on the paper pattern for<br />
installation (3), so refer to it when considering the<br />
necessity for reinforcing the location.)<br />
14. Obey the local and national regulations and limits<br />
regarding airconditioner installation.<br />
15. Location free from lavatory (NH3.etc.). NH3 gas will<br />
cause corrosion <strong>of</strong> outdoor unit metallic parts.<br />
4.1.4 For the following items, take special care during construction and check<br />
after installation is finished<br />
1. Items to be checked after com<strong>pl</strong>etion <strong>of</strong> work<br />
Unit<br />
Are the indoor and outdoor unit fixed firmly? The units may drop, vibrate or make noise.<br />
Is the gas leak test finished? It may result in insufficient cooling.<br />
Is the unit fully insulated? Condensate water may drip.<br />
Does drainage flow smoothly? Condensate water may drip.<br />
Does the power sup<strong>pl</strong>y voltage correspond to that<br />
shown on the name <strong>pl</strong>ate?<br />
The unit may malfunction or the components burn out.<br />
Are wiring and piping correct? The unit may malfunction or the components burn out.<br />
Is the unit safely grounded? It may be dangerous at electric leakage.<br />
Is wiring size according to specifications? The unit may malfunction or the components burn out.<br />
Is something blocking the air outlet or inlet <strong>of</strong><br />
either the indoor or outdoor units?<br />
It may result in insufficient cooling.<br />
Are refrigerant piping length and additional<br />
refrigerant charge noted down?<br />
The refrigerant charge in the system is not clear.<br />
CAUTION<br />
NOTE<br />
Items to be checked If not properly done, what is likely to occur Check<br />
• Be very careful about product transportation.<br />
Some products use PP bands for packaging. Do not use any PP bands for a means <strong>of</strong> transportation. It is dangerous.<br />
• Safely dispose <strong>of</strong> the packing materials.<br />
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.<br />
Tear apart and throw away <strong>pl</strong>astic packaging bags so that children will not <strong>pl</strong>ay with them. If children <strong>pl</strong>ay with a <strong>pl</strong>astic<br />
bag which was not torn apart, they face the risk <strong>of</strong> suffocation.<br />
• Install the indoor and outdoor units, power sup<strong>pl</strong>y wiring and connecting wires at least 1m. away from televisions<br />
or radios in order to prevent image interference or noise.<br />
(Depending on the radio waves, a distance <strong>of</strong> 1m. may not be sufficient enough to eliminate the noise.)<br />
Installation <strong>of</strong> outdoor unit 357
Safety Precautions<br />
4.1.5 Before installation<br />
5CSL0-06B<br />
• During product unpacking and removing it from the packing case, be sure to lift it without exerting any pressure<br />
on other parts, especially, horizontal flaps, the refrigerant piping, drain piping, and other resin parts.<br />
• Be sure to remove a cushion (corrugated paper) located between the heat exchanger and the right air filter.<br />
• Be sure to check the type <strong>of</strong> R410A refrigerant to be used before installing the unit. (Using an incorrect refrigerant will prevent<br />
normal operation <strong>of</strong> the unit.)<br />
• The accessories needed for installation must be retained in your custody until the installation work is com<strong>pl</strong>eted. Do not<br />
discard them!<br />
• Decide upon a line <strong>of</strong> transport.<br />
• Leave the unit inside its packaging while moving, until reaching the installation site. Where unpacking is unavoidable, use<br />
a sling <strong>of</strong> s<strong>of</strong>t material or protective <strong>pl</strong>ates together with a rope when lifting, to avoid damage or scratches to the unit.<br />
• For the installation <strong>of</strong> an outdoor unit, refer to the installation manual attached to the outdoor unit.<br />
• When using the wireless remote controller, refer to the installation manual attached to the wireless remote controller.<br />
• Entrust installation to the <strong>pl</strong>ace <strong>of</strong> purchase or an authorized serviceman. Improper installation could lead to leaks and in<br />
worst cases, electric shock <strong>of</strong> fire.<br />
• Use only parts provided with the unit or parts satisfying required specifications. Unspecified parts could cause the unit to<br />
fall out <strong>of</strong> <strong>pl</strong>ace, or could lead to leaks and, in the worst cases, electric shock or fire.<br />
358 Installation <strong>of</strong> outdoor unit
5CSL0-06B Introduction<br />
4.2 Introduction<br />
This installation guidance describes the procedures for outdoor unit installation, piping, wiring, and control between outdoor<br />
units, indoor units and controller.<br />
Installation <strong>of</strong> the indoor units is not described in this part. Please refer to the installation guidance manual which sup<strong>pl</strong>ied<br />
with indoor units for their respective installation.<br />
4.2.1 Lifting method<br />
1. When carrying the unit suspended, pass the ropes under<br />
the unit and use the two fork lift slots each at the front<br />
and rear.<br />
2. Always lift the unit with ropes attached at four points so<br />
that impact is not ap<strong>pl</strong>ied to the unit.<br />
3. Attach the ropes to the unit at an angle <strong>of</strong> 40° or less.<br />
4. Use two ropes at least 7 m long.<br />
CAUTION<br />
Be very careful when carrying the product.<br />
• PP bands are used to pack some products. Do not use<br />
them as a mean for transportation because they are<br />
dangerous.<br />
• Do not touch heat exchanger fins with your bare hands.<br />
Otherwise you may get a cut.<br />
• Tear <strong>pl</strong>astic packaging bag and scrap it so that children<br />
cannot <strong>pl</strong>ay with it. Otherwise <strong>pl</strong>astic packaging bag<br />
may suffocate children to death.<br />
• When carrying in outdoor unit, be sure to support it at<br />
four points. Carrying in and lifting with 3-point support<br />
may make outdoor unit unstable, resulting in a fall <strong>of</strong> it.<br />
4.2.2 Inspecting and handling the<br />
unit<br />
At the time <strong>of</strong> delivery, the package should be checked for<br />
any damage from out side and inside, If damaged then it<br />
should be reported to the carrier claims agent immediately .<br />
When handling the unit refer to following cautions:<br />
1. Handle the unit with care. Keep the unit upright in order<br />
to avoid inside components damage.<br />
2. If a forklift is to be used it should pass the forklift arms<br />
through the openings at the bottom <strong>of</strong> the unit.<br />
3. If a crane is used, lift the unit preferably with 2 ropes <strong>of</strong><br />
at least 7m length.<br />
4. When lifting the unit with a crane, always use protectors<br />
to prevent belt damage and pay attention to the position<br />
<strong>of</strong> the unit's center <strong>of</strong> gravity.<br />
5. Bring the unit in original package to prevent damage<br />
during local transport.<br />
Installation <strong>of</strong> outdoor unit 359
Foundation<br />
4.3. Foundation<br />
For good drain <strong>of</strong> outdoor unit, keep the bottom height from icing upward.<br />
AUUW096D [ULD]<br />
AUUW126D [ULD]<br />
AUUH126D [ULD]<br />
<br />
Bolt Factor M10-J type<br />
Concrete height 100mm or more<br />
Bolt inserted depth 70mm or more<br />
AUUW186D [UED],*AUUW186DH [UED]<br />
AUUW186D1[UED1]<br />
AUUW246D[UU24W UED], AUUW306D[UU30W UED]<br />
AUUH186D [UED]<br />
AUUH246D[UU24 UED], AUUH306D[UU30 UED]<br />
<br />
Bolt Factor M10-J type<br />
Concrete height 100mm or more<br />
Bolt inserted depth 70mm or more<br />
* AUUW186DH : DISCHARGE GRILLE SHPE IS<br />
DOFFERENT<br />
AUUW366D[UU36W UED]<br />
AUUW368D[UU37W UED]<br />
AUUH368D[UU37 UED]<br />
<br />
Bolt Factor M10-J type<br />
Concrete height 200mm or more<br />
Bolt inserted depth 70mm or more<br />
100mm<br />
or more<br />
100mm<br />
or more<br />
100mm<br />
or more<br />
546mm 370mm or more<br />
518mm 287mm or more<br />
550mm 360mm or more<br />
5CSL0-06B<br />
360 Installation <strong>of</strong> outdoor unit
5CSL0-06B Foundation<br />
AUUW426D[UU42W U3D], AUUW486D[UU42W U3D]<br />
AUUW606D[UU60W U3D], AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D], AUUW608D[UU61W U3D]<br />
AUUH488D[UU48 U3D], AUUH608D[UU60 U3D]<br />
<br />
Bolt Factor M10-J type<br />
Concrete height 200mm or more<br />
Bolt inserted depth 70mm or more<br />
Diagram <strong>of</strong> lower<br />
surface<br />
AUUW216DH[UU21WH U4D]<br />
AUUW246DH[UU24WH U4D]<br />
<br />
Bolt Factor M10-J type<br />
Concrete height 200mm or more<br />
Bolt inserted depth 70mm or more<br />
Diagram <strong>of</strong> lower<br />
surface<br />
20<br />
20<br />
200mm<br />
or more<br />
200mm<br />
or more<br />
Installation <strong>of</strong> outdoor unit 361<br />
200mm<br />
200mm<br />
400mm 620mm or more<br />
400mm 620mm or more
Settlement <strong>of</strong> the outdoor unit<br />
5CSL0-06B<br />
4.4 Settlement <strong>of</strong> the outdoor unit 4.5 Selection <strong>of</strong> the best location<br />
• Anchor the outdoor unit with a bolt and nut tightly and<br />
horizontally on a concrete or rigid mount.<br />
• When installing on the wall, ro<strong>of</strong> or ro<strong>of</strong>top, anchor the<br />
mounting base securely with a nail or wire assuming the<br />
influence <strong>of</strong> wind and earthquake.<br />
• In the case when the vibration <strong>of</strong> the unit is conveyed to<br />
the house, secure the unit with an anti-vibration rubber.<br />
Bolt construction work<br />
Settlement draw <strong>of</strong> outdoor units<br />
Bolt<br />
CAUTION<br />
Mechanical anchor bolt<br />
M10<br />
Diagram <strong>of</strong> lower surface<br />
60~120<br />
20<br />
Tubing connection<br />
• The ingredients <strong>of</strong> foundation : Cement : Sand : Gravel<br />
for the concrete should 1 : 2 : 4 ratio<br />
• The foundation surface should be finished with mortar.<br />
• The edges <strong>of</strong> foundation should be rounded.<br />
• A drain passage should be made around the foundation<br />
to thoroughly drain water away from the equipment<br />
installation area.<br />
• If installing the outdoor units on the ro<strong>of</strong>, the ro<strong>of</strong>'s<br />
strength have to be checked.<br />
• Care should be taken for weather - pro<strong>of</strong>ing<br />
• Blocking all gaps <strong>of</strong> outdoor unit, for passing piping and<br />
wiring, using sealing material (Field sup<strong>pl</strong>y)<br />
(Animals and bugs might enter in the machine.)<br />
This Single A unit is suitable for installation in a residential<br />
and commercial environmental situation.<br />
If installed near a household ap<strong>pl</strong>iance it can cause electromagnetic<br />
interference.<br />
The units should be installed in a location that meets the following<br />
requirements:<br />
1. A robust and strong base which can support the weight <strong>of</strong><br />
the unit and will not degrade easily<br />
2. If an awning is built over the unit to prevent direct sunlight<br />
or rain exposure, make sure that the discharge air <strong>of</strong> the<br />
condenser is not restricted.<br />
3. It is recommended that the outdoor unit should be fenced<br />
to avoid animals or <strong>pl</strong>ants being exposed in the direct<br />
path <strong>of</strong> the discharged air .<br />
4. Ensure proper spaces between the unit and its surrounding<br />
as given in the figure.<br />
5. Ensure that the water shall not cause any damage by<br />
overflowing in case <strong>of</strong> water condensation<br />
6. The noise, vibration and hot discharged air <strong>of</strong> the outdoor<br />
unit should not annoy the surrounding environment.<br />
7. Ensure that there is no damage to the pipes in long run<br />
as it may cause the refrigerant leakage.<br />
8. In case the outdoor may have heavy snow :<br />
a. Make foundation at a suitable height not for ice to grow<br />
upward.<br />
b. Fit a suitable hood or a awning over the unit not to<br />
attach outdoor unit heat exchanger directly.<br />
c. In very cold snowing area, <strong>pl</strong>ease consult with your<br />
consultant.<br />
9. Ro<strong>of</strong>top Installations : If the outdoor unit is installed on a<br />
ro<strong>of</strong> structure, be sure to level the unit. Ensure the ro<strong>of</strong><br />
structure and anchoring method are adequate for the unit<br />
location. Consult local codes regarding ro<strong>of</strong>top mounting.<br />
CAUTION<br />
An inverter air conditioner can cause electronic noise<br />
generated from broadcasting frequency. Make sure to<br />
maintain proper distances between the products and<br />
electric wires keeping away from stereo, TV set or other<br />
ap<strong>pl</strong>iances<br />
1. Branch switch, over current breaker<br />
2. Remote controller<br />
3. Cool/heat selector<br />
4. Radio or TV set<br />
5. Wireless microphone<br />
If frequency signal <strong>of</strong> AM broadcasting or TV Set is non<br />
stable, keep distances <strong>of</strong> 3m or more from product and<br />
use electric wire along with conduit tubes for power and<br />
transmission cable.<br />
362 Installation <strong>of</strong> outdoor unit
5CSL0-06B Selection <strong>of</strong> the best location<br />
CAUTION<br />
1. Actually the R410A refrigerant is not toxic, nonflammable and odor free. Any how if the refrigerant is leaked then its<br />
concentration may exceed the allowable limit depending on the related space volume.<br />
Due to this, it is necessary to take measures for the volume size against leakage.<br />
2. Do not install unit in following locations.<br />
• Locations where sulfurous acids or this kind <strong>of</strong> other corrosive gases might be help to corrode <strong>of</strong> copper piping and<br />
soldered joints, and can cause refrigerant leakage.<br />
• Locations such as kitchens or cuisine which contain a lot <strong>of</strong> hot oil or steam or where oil may s<strong>pl</strong>atter to the product.<br />
Can cause the unit to make leak or other serious problem.<br />
• Locations where electromagnetic waves is prevalent. The electromagnetic waves may cause the control system to<br />
malfunction or causing an abnormal operation.<br />
• Locations where inflammable gas might leak, where combined gasoline, methane or other volatile substances, carbon<br />
dust and other incendiary substances are found in the atmosphere. Leaked gas may accumulate around the unit, can<br />
cause an serious ex<strong>pl</strong>osion.<br />
Installation <strong>of</strong> outdoor unit 363
Clearance space 5CSL0-06B<br />
4.6 Clearance space<br />
4.6.1 Clearance around outdoor unit<br />
AUUW096D [UU09W ULD]<br />
AUUW126D [UU12W ULD]<br />
AUUW186D [UU18W UED]<br />
AUUW186D1[UU18W UED1]<br />
AUUW246D[UU24W UED]<br />
AUUW306D[UU30W UED]<br />
AUUH126D [UU12 ULD]<br />
AUUH186D [UU18 UED]<br />
AUUH246D[UU24 UED]<br />
AUUH306D[UU30 UED]<br />
200 mm or more<br />
300 mm<br />
or more 300 mm<br />
or more<br />
300 mm<br />
or more<br />
200 mm or more<br />
300 mm<br />
or more<br />
200 mm<br />
or more<br />
Fence or<br />
obstacles<br />
Air inlet grille<br />
Sunro<strong>of</strong><br />
100 100 mm<br />
mm<br />
or or more<br />
600 mm or m<br />
(Service spac<br />
More than 50cm<br />
(Service space)<br />
• Ensure that the space around the back is more than 200 mm on the opposite to the PCB side and secure 600 mm<br />
space near the compressor and PCB side <strong>of</strong> the aircondition for service.<br />
AUUW366D[UU36W UED]<br />
AUUW368D[UU37W UED]<br />
AUUH368D[UU37 UED]<br />
AUUW216DH [UU21WH U4D]<br />
AUUW246DH [UU24WH U4D]<br />
• Ensure that the space around the back is<br />
more than 300 mm on the opposite side<br />
to the PCB side and secure 600 mm<br />
space near the compressor and PCB<br />
side <strong>of</strong> the air conditioner for service.<br />
AUUW426D[UU42W U3D]<br />
AUUW486D[UU42W U3D]<br />
AUUW606D[UU60W U3D]<br />
AUUW428D[UU43W U3D]<br />
AUUW488D[UU49W U3D]<br />
AUUW608D[UU61W U3D]<br />
AUUH488D[UU48 U3D]<br />
AUUH608D[UU60 U3D]<br />
• Install the unit so that its discharge port faces to the<br />
wall <strong>of</strong> the building.<br />
Keep a distance 500mm or more between the unit<br />
and the wall surface.<br />
• Supposing the wind direction during the operation<br />
season <strong>of</strong> the air conditioner, install the unit so that<br />
the discharge port is set at right angle to the wind<br />
direction.<br />
300 mm<br />
or more<br />
Fence or<br />
obstacles<br />
Sunro<strong>of</strong><br />
Turn the air outlet side toward the<br />
building's wall, fence or windbreak<br />
screen.<br />
300 mm<br />
or more<br />
600 mm or more<br />
(Service space)<br />
More than 50cm<br />
(Service space)<br />
364 Installation <strong>of</strong> outdoor unit<br />
500<br />
Strong<br />
wind<br />
Blown<br />
air<br />
Sunro<strong>of</strong><br />
Strong<br />
wind<br />
Set the otlet side at a rignt angle<br />
to the direction <strong>of</strong> the wind.
5CSL0-06B<br />
Clearance <strong>of</strong> side discharge unit (unit : mm).<br />
1. Where there is an obstacle on the air intake side:<br />
■ No obstacle above<br />
• Obstacle on the suction side only • Obstacle on the both sides<br />
100 or more<br />
■ Obstacle above, too<br />
• Obstacle on the air intake side, too • Obstacle on the air intake side, and both sides<br />
500 or less<br />
100 or more<br />
1000 or more<br />
500 or more<br />
Clearance space<br />
Installation <strong>of</strong> outdoor unit 365<br />
300 or more<br />
2. Where there is an obstacle on the discharge side:<br />
300 or more<br />
600 or more<br />
500 or less<br />
600 or more<br />
■ No obstacle above ■ Obstacle above, too<br />
3. Where there are obstacles on both suction and discharge sides:<br />
■ Where the obstacles on the discharge side is higher than the unit:<br />
• No obstacle above<br />
• Obstacle above, too<br />
The relations between H, A and L are as follows:<br />
L A<br />
L ≤ H<br />
0 < L ≤ 1/2H<br />
1/2H < L<br />
750<br />
1000<br />
H < L Set the stand as: L ≤ H<br />
Close the bottom <strong>of</strong> the installation frame to prevent<br />
the discharged air from being bypassed.<br />
100 or more<br />
1000 or more<br />
150 or more<br />
H<br />
500 or less<br />
500 or more<br />
500 or more<br />
A<br />
500 or less<br />
1000 or more<br />
100 or more<br />
L<br />
1000 or more<br />
200 or more
Clearance space 5CSL0-06B<br />
■ Where the obstacles on the discharge side is lower than the unit:<br />
• No obstacle above<br />
• Obstacle above, too<br />
The relations between H, A and L are as follows:<br />
L A<br />
L ≤ H<br />
0 < L ≤ 1/2H<br />
1/2H < L<br />
100<br />
200<br />
H < L Set the stand as: L ≤ H<br />
Close the bottom <strong>of</strong> the installation frame to prevent<br />
the discharged air from being bypassed.<br />
4. Series installation<br />
4.6.2 Air guide work<br />
In case <strong>of</strong> out door unit is located outdoor cabin <strong>of</strong> apartment<br />
or flats, then the efficiency can drop and system<br />
pressure increases thus finally damaging the compressor<br />
or other components in the system by heat short circuit.<br />
4.6.3 Lightning safety zone<br />
1) To protect outdoor unit from lightning, it should be <strong>pl</strong>aced<br />
within lightning safety zone.<br />
Safety zone<br />
Building Height [m] 20 30 45 60<br />
Protection Angle [˚] 55 45 35 25<br />
2) Power cable and communication cable should be 1.5m<br />
away from lightning rod.<br />
3) High resistance grounded system should be performed<br />
against induced lightning or indirect stroke.<br />
4) If the building has no lightning protection, outdoor may be<br />
damage from lightning. This should be informed to customer<br />
or building owner in advance.<br />
500 or more<br />
[Exam<strong>pl</strong>e]<br />
1000 or more<br />
<br />
Safety dorice activation<br />
Lightning rod<br />
Protection Angle (25˚~55˚)<br />
<br />
Normal operation<br />
366 Installation <strong>of</strong> outdoor unit<br />
Lightning rod<br />
100 or more<br />
1.5m<br />
Ground<br />
500 or more<br />
L<br />
500 or less<br />
Safe zone<br />
100 or more<br />
500 or more<br />
A<br />
H<br />
1000 or more<br />
※ Regarding the safety<br />
from atmosphere<br />
electricity, follow the<br />
local or national<br />
regulations
5CSL0-06B<br />
4.7 Outdoor unit piping<br />
4.7.1 Outdoor unit piping<br />
Required tools<br />
4.7.2 Connecting piping<br />
1) Connecting socket must be used when connecing the piping to the indoor and outdoor units<br />
■ Branching kit<br />
C<br />
Outdoor unit piping<br />
Screw Driver Drill M/C f 3.5/F14.5 Measuring Tape, Blade Core drill Spanner Torque Wrench<br />
Soap Foam Thermometer Hexagonal wrench(4mm, 5mm) Hook Meter Multi Tester Flare Set<br />
A<br />
Indoor Classification Model Name Capacity Ratio(%)<br />
2 Units PMUB11A 50:50 (1:1)<br />
3 Units PMUB111A 33:33:33 (1:1:1)<br />
4 Units PMUB1111A 25:25:25:25(1:1:1:1)<br />
B<br />
2) Finally, tighten the flare nut with torque wrench until the wrench clicks.<br />
• When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow on the wrench.<br />
Suction Line piping<br />
(Bigger diameter)<br />
Torque wrench<br />
D<br />
Evaporator Line<br />
piping<br />
(Smaller<br />
diameter)<br />
a b c<br />
a b<br />
Type 1 Type 2<br />
Unit : mm (inch)<br />
(I.D) ⓐ ⓑ ⓒ Type<br />
Ⓐ Ø15.88(5/8) Ø19.05(3/4) Ø25.4(1) 1<br />
Ⓑ<br />
Ø9.52(3/8)<br />
Ø12.7(1/2) Ø12.7(1/2)<br />
Ø15.88(5/8)<br />
- 2<br />
Ⓒ Ø6.35(1/4) Ø9.52(3/8) - 2<br />
Ⓓ Ø9.52(3/8) Ø12.7(1/2) - 2<br />
Continuous<br />
Torque<br />
wrench<br />
(250mm )<br />
Installation <strong>of</strong> outdoor unit 367<br />
➝<br />
❈ When tighten the pipe, hold the haxagonal body.
Outdoor unit installation requirments 5CSL0-06B<br />
4.8 Outdoor unit installation requirments<br />
4.8.1 Piping elevation and length<br />
• For 1 Phase Inverter Model<br />
Model<br />
UU09W/UU12W<br />
UU18W<br />
UU24W<br />
UU30W<br />
UU36W<br />
UU42W<br />
UU48W<br />
UU60W<br />
Model<br />
UU37W<br />
UU43W<br />
UU49W<br />
UU61W<br />
Pipe Size (Diameter:Ø) Length(m) Elevation(m) *Additional<br />
Gas Liquid Standard Max. Max. refrigerant(g/m)<br />
9.52 (3/8)<br />
12.7 (1/2)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
• For 3 Phase Inverter Model<br />
6.35 (1/4)<br />
6.35 (1/4)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
5.0<br />
5.0<br />
5.0<br />
5.0<br />
5.0<br />
7.5<br />
7.5<br />
7.5<br />
368 Installation <strong>of</strong> outdoor unit<br />
15<br />
40<br />
50<br />
50<br />
50<br />
75<br />
75<br />
75<br />
10<br />
30<br />
30<br />
30<br />
30<br />
30<br />
30<br />
30<br />
Pipe Size (Diameter:Ø) Length(m) Elevation(m)<br />
Gas Liquid Standard Max. Max.<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
• For Non-inverter Model<br />
Model<br />
UU12<br />
UU18<br />
UU24<br />
UU30<br />
UU36<br />
UU48<br />
UU60<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
Pipe Size (Diameter:Ø)<br />
5.0<br />
7.5<br />
7.5<br />
7.5<br />
50<br />
75<br />
75<br />
75<br />
30<br />
30<br />
30<br />
30<br />
Length(m) Elevation(m)<br />
Gas Liquid Standard Max. Max.<br />
9.52 (3/8)<br />
12.7 (1/2)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
15.88 (5/8)<br />
6.35 (1/4)<br />
6.35 (1/4)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
9.52 (3/8)<br />
5.0<br />
5.0<br />
5.0<br />
5.0<br />
5.0<br />
7.5<br />
7.5<br />
15<br />
50<br />
40<br />
50<br />
50<br />
50<br />
40<br />
10<br />
30<br />
30<br />
30<br />
30<br />
30<br />
30<br />
20<br />
20<br />
35<br />
35<br />
50<br />
40<br />
40<br />
40<br />
*Additional<br />
refrigerant(g/m)<br />
45<br />
40<br />
40<br />
40<br />
*Additional<br />
refrigerant(g/m)<br />
20<br />
35<br />
45<br />
45<br />
45<br />
50<br />
50
5CSL0-06B<br />
❈ Extra refrigerant = (Extended length - Rated length) x Additional refrigerant.<br />
CAUTION<br />
2) DC inverter Single A - synchro<br />
Outdoor unit installation requirments<br />
Install the branch pipe so that pipe length and difference between high and low will not exceed below SPEC.<br />
h1<br />
Indoor unit<br />
L2<br />
L3<br />
L4<br />
L5<br />
B<br />
Main (L1)<br />
A<br />
Outdoor unit<br />
Branch<br />
Indoor unit<br />
• When installing the branch pipe, direction and angle <strong>of</strong> installation is not limited.<br />
• Take care so that burrs and foreign material may not enter into the cutting surface when connecting.<br />
• Donʼt use the liquid pipe by too bending or twisting.<br />
h2<br />
Outdoor unit<br />
• Capacity is based on standard length and maximum allowance length is on the basis <strong>of</strong> reliability.<br />
• Improper refrigerant charge may result in abnormal cycle.<br />
A<br />
Pipe Length(m)<br />
Total(Main+Branch)<br />
L1+L2+L3+L4+L5<br />
Main Pipe(L1)<br />
Total Branch Pipe<br />
Each Barnch(L2, L3, L4, L5)<br />
In out (h1)<br />
In-In (h2)<br />
L1+L2, L1+L3, L1+L4, L1+L5<br />
Indoor-Indoor_(b)<br />
L2-L3, L4-L5<br />
AUUW42~606(8)D<br />
Installation <strong>of</strong> outdoor unit 369<br />
B<br />
80<br />
50<br />
40<br />
15<br />
30<br />
1<br />
70<br />
10
Outdoor unit installation requirments 5CSL0-06B<br />
Refrigerant Additional Charging Method<br />
For additional charging method, see below table.<br />
NOTE<br />
Synchro Refrigerant Additional charging (kg)<br />
Duo<br />
Trio<br />
Quartet<br />
(L1=Main Pipe, L2~L5 : Branch Pipe)<br />
Model<br />
AUUW42-606(8)D 7.5 m<br />
NOTE<br />
CAUTION<br />
If the total additional charge value after calculation comes out to be negative, then do not consider additional charge.<br />
Long pipe setting (Inverter Single A)<br />
1. Open the side panel <strong>of</strong> outdoor unit.<br />
2. Set the DIP SW2 as below Fig.<br />
DIP SW2<br />
ON<br />
1 2 3 4 5<br />
0 0 0 1 0<br />
3. Close the side panel and check whether the<br />
product works normally.<br />
CAUTION<br />
Refrigerant = (L1-a) x B + (L2 + L3) x A<br />
Refrigerant = (L1-a) x B + (L2 + L3 + L4) x A<br />
Refrigerant = (L1-a) x B + (L2 + L3 + L4 + L5) x A<br />
a<br />
✽ 1 means S/W up.<br />
0 means S/W down.<br />
Do not open the top cover or set the pipe<br />
length when operating the product.<br />
B<br />
0.04 kg/m<br />
Refrigerant Branch<br />
Pipe (mm)<br />
370 Installation <strong>of</strong> outdoor unit<br />
Ø 6.35<br />
Ø 9.52<br />
DIP SW2<br />
ON<br />
1 2 3 4 5<br />
A<br />
0.03 kg/m<br />
0.04 kg/m<br />
If total additional charge value after calculation comes out to be negative, then do not consider additional charge.<br />
a Standard piping length<br />
A Refrigerant Additional charging (For Branch Pipe)<br />
B Refrigerant Additional charging (For Main Pipe)<br />
• Rated performance for refrigerant line length <strong>of</strong> 7.5m.<br />
• Capacity is based on standard length and maximum allowance length is on the basis <strong>of</strong><br />
reliability.<br />
• Improper refrigerant charge may result in abnormal cycle.
5CSL0-06B<br />
1. DIP SW2 Setting<br />
Set the DIP SW2 as below Table.a (Ⓐ)<br />
❈ 1 means S/W up.<br />
0 means S/W down.<br />
2. Auto Addressing Method<br />
Addressing work assigns address to each indoor<br />
unit. When firstly installing product or re<strong>pl</strong>acing the<br />
indoor unit PCB.Auto Addressing work should be<br />
done for simultaneous operation.<br />
❈ Work procedure<br />
1) DIP SW2 correctly.<br />
2) Turn on main power.<br />
3) Press the SW01B for about 3 seconds within 3minutes<br />
After main power on.(Ⓑ)<br />
4) After step 3), the LED01H(green LED) rapidly flickers.When<br />
Addressing work is done, green LED is<br />
<strong>of</strong>f, else LED stops flickering and lights continuously.<br />
5) If you fail to perform the Addressing work, repeat<br />
step 2),3).<br />
CAUTION<br />
1. Regulation for refrigerant leakage<br />
: the amount <strong>of</strong> refrigerant leakage should satisfy the following equation for human safety.<br />
Total amount <strong>of</strong> refrigerant in the system<br />
Volume <strong>of</strong> the room at which indoor unit <strong>of</strong> the least capacity is installed<br />
Outdoor unit installation requirments<br />
Table.a DIP SW2 Setting<br />
DIP SW2 Indoor Unit No.<br />
≤ 0.3 ( kg / m 3 )<br />
2. If the above equation can not be satisfied, then follow the following steps.<br />
① Selection <strong>of</strong> air conditioning system: select one <strong>of</strong> the followings.<br />
• Effective opening part Installation<br />
• Reconfirmation <strong>of</strong> outdoor unit capacity and piping length<br />
• Reduction <strong>of</strong> the amount or refrigerant<br />
• 2 or more security device installation <strong>of</strong> alarm for gas leakage<br />
② Change indoor unit type<br />
: installation position should be over 2m from the floor (Wall mounted type Cassette type)<br />
③ Adoption <strong>of</strong> ventilation system<br />
: choose ordinary ventilation system or building ventilation system<br />
④ Limitation in piping work<br />
: design for earthquake-pro<strong>of</strong> and prevention against thermal stress<br />
1(Single)<br />
2(Duo)<br />
3(Trio)<br />
4(Quartet)<br />
Installation <strong>of</strong> outdoor unit 371<br />
DIP SW2<br />
ON<br />
A<br />
LED01H<br />
B<br />
ON<br />
1 2 3 4 5<br />
0 0 0 0 0<br />
ON<br />
1 2 3 4 5<br />
1 0 0 0 0<br />
ON<br />
1 2 3 4 5<br />
1 1 0 0 0<br />
ON<br />
1 2 3 4 5<br />
SW01B<br />
1 2 3 4 5<br />
1 1 1 0 0<br />
MAIN PCB
Outdoor unit cabin 5CSL0-06B<br />
4.9 Outdoor unit cabin<br />
4.9.1 Outdoor Cabin louver requirement<br />
1. Outdoor cabin type : Manual door open type<br />
2. Louver angle : less than 15° on the horizontal base<br />
3. Louver interval: over 100mm (recommend)<br />
4. Louver shape : wing type or <strong>pl</strong>ane type<br />
CAUTION<br />
• Opening rate and suction should be considered for<br />
louvered outdoor room.<br />
• Do not use 'S' type louver.<br />
NOTE<br />
Noise can occur due to the<br />
backward flow <strong>of</strong> the air<br />
passing through the louver<br />
blade<br />
Louver<br />
Outside<br />
Max15°<br />
(Recommended)<br />
Over 100mm<br />
(Recommended)<br />
Section<br />
Inside<br />
The problem in case the louver opening rate is small.<br />
1. Noise can occur due to the increased velocity <strong>of</strong> the air passing through louver blade.<br />
2. Noise can occur due to the louver blade vibrations.<br />
3. Drop in outdoor fan performance (Excess static pressure damage can cause drop in the performance as well as outdoor<br />
heat exchange efficiency).<br />
4. In case the louver opening rate is small or there is insufficient air flow exchange, it might stop the air conditioner.<br />
Opening rate by louver radian<br />
≤ 15°<br />
ho = h * COS<br />
Total face area(A) = H * W<br />
Number <strong>of</strong> open space (N) = (number <strong>of</strong> louver - 1)<br />
Effective face area(Af) = ho * W * N<br />
Louver opening rate (n) = Af/A<br />
Af = A * n<br />
ho<br />
Effective face area <strong>of</strong> cross section<br />
h<br />
[Side view]<br />
372 Installation <strong>of</strong> outdoor unit<br />
W<br />
[Front view]<br />
H
5CSL0-06B<br />
4.9.2 Air flow rate confirmation<br />
Exam<strong>pl</strong>e. 1<br />
■ Ap<strong>pl</strong>ication Model : AUUW366D [UU36W UED] Airflow rate 106CMM<br />
[Total opening rate]<br />
1400mm<br />
1200mm<br />
1900mm<br />
Air guide duct<br />
1380 mm<br />
■ Louver total dimension (excluding frame) (A) = 1.2 m x 1.9 m = 2.28 m 2<br />
■ Louver shielding dimension by product (B) = 0.9 m x 1.13 m = 1.02 m 2<br />
■ Suction able louver dimension (A-B) = 1.26m 2<br />
■ Equivalent suction dimension (Opening rate 80%) = 1.26 m 2 x 0.8 = 1.01 m 2<br />
■ Equivalent suction air volume = 1.2816 m 2 x 2.5 m/s x 60s/m = 152 CMM<br />
■ Required air volume / equivalent voloume = 152 CMM / 106 CMM(product airflow rate) = 142 %<br />
➡ OK<br />
950mm<br />
■ Case : velocity <strong>of</strong> discharging air: 5m/s,<br />
velocity <strong>of</strong> suction air: 2.5m/s<br />
■ Openness rate = 80% or more<br />
✻ Openness rate =<br />
Effective face area(Af)<br />
Total face area(A)<br />
Outdoor unit cabin<br />
■ Air guide <strong>of</strong> discharging air part should be equipped.<br />
Installation <strong>of</strong> outdoor unit 373
5CSL0-06B<br />
374 Installation <strong>of</strong> outdoor unit
Part 4 Accessories<br />
List <strong>of</strong> ap<strong>pl</strong>icable models<br />
1. Controller accessories .......................................................................377<br />
1.1 Wireless remote controller .........................................................................................377<br />
1.2 Sim<strong>pl</strong>e remote controller ............................................................................................382<br />
1.3 Deluxe remote controller............................................................................................384<br />
1.4 Hotel use remote controller........................................................................................386<br />
1.5 Zone controller ...........................................................................................................388<br />
1.6 Dry contact module ....................................................................................................391<br />
2. Mechanical accessories............................................................................393<br />
2.1 Branch kit ...................................................................................................................393<br />
2.2 Drain pump ................................................................................................................395<br />
2.3 Air guide.....................................................................................................................400<br />
2.4 Cassette cover ...........................................................................................................401<br />
Accessories 375
List <strong>of</strong> ap<strong>pl</strong>icable models 5CSL0-06B<br />
List <strong>of</strong> ap<strong>pl</strong>icable models<br />
Individual<br />
control<br />
CAC Network<br />
function<br />
Special<br />
function kit<br />
Wired Remote Controller(Deluxed)<br />
Wired Remote Controller(Sim<strong>pl</strong>e)<br />
Wired Remote Controller(for hotel use)<br />
Picto wired remote controlxer<br />
Wireless Remote Controller<br />
General Central Controller(Non LGAP)<br />
Network Function(LGAP)<br />
PI485<br />
Function<br />
Dry_Contact<br />
PDI(Power Distribution Indicator)<br />
Low Ambient Kit<br />
Zone Controller (for Duct)<br />
Model name<br />
Wall mounted Artcool CST Ceiling & Floor Duct<br />
X X PQRCUDS0 X PQRCUDS0<br />
X X PQRCUCA0 PVRCUSZ0 PQRCUCA0<br />
X X PQRCFCS0 X PQRCFCS0<br />
X X PQRCUSA0 X X<br />
X X "PQWRHSF0 X "PQWRHSF0<br />
X X AHWRHD X AHWRHD<br />
X X AHWRHS X AHWRHS<br />
X X X X X<br />
O O O O O<br />
PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0 PMNFP14A0<br />
PQDSB PQDSB PQDSB PQDSB PQDSB<br />
PQNUD1S00 PQNUD1S00 PQNUD1S00 PQNUD1S00 PQNUD1S00<br />
AQLA AQLA AQLA AQLA AQLA<br />
X X X X ABZCA<br />
376 Accessories
5CSL0-06B Wireless remote controller<br />
1. Controller accessories<br />
1.1 Wireless remote controller<br />
Picture:<br />
Functions:<br />
A Wireless remote controller allows the operation <strong>of</strong> air conditioner from any corner <strong>of</strong> the room<br />
Ap<strong>pl</strong>icable Models:<br />
Ceiling cassete<br />
Ceiling concealed duct<br />
PQWRHSF0<br />
AHWRHD<br />
AHWRHS<br />
Functions PQWRHSF0 AHWRHD AHWRHS<br />
Air circulation / Fan operation<br />
Room temperature checking<br />
Sleep mode operation<br />
Temperature settings<br />
Operation mode selection<br />
Air-swing & Jet cool (Cassette Only)<br />
On/Off Timer settings<br />
Accessory: Wireless remote control ............................................................................................................................1EA<br />
Owner's manual ........................................................................................................................................1EA<br />
Controller accessories 377
Wireless remote controller<br />
Installation procedure:<br />
Mounting on the wall<br />
1) Mount the remote control stand on the wall with the help <strong>of</strong> screw driver and screw purchased<br />
locally.<br />
2) Insert the remote control in the stand.<br />
How to insert batteries:<br />
1) Remove the battery cover from the remote control. Slide the cover in the direction <strong>of</strong> arrow.<br />
2) Insert two batteries. Take care about the polarity(+/-) and batteries should be new.<br />
3) Re-<strong>pl</strong>ace the cover by sliding it back into position.<br />
How to use<br />
For ceiling cassette :<br />
Point the signal transmitter towards the front panel <strong>of</strong> the cassette indoor unit (for C, D, E, F<br />
Chassis models) and press any function key. For B chassis point the signal transmitter towards<br />
the wired remote control and press any function key.<br />
For ceiling concealed duct, ducted s<strong>pl</strong>it & Single package :<br />
Point the signal transmitter towards the wired remote control and press any function key.<br />
Remarks<br />
1. Do not use rechargeable batteries for wireless remote control .<br />
2. Remove the batteries from the remote control if the air conditioner is not going to be used for<br />
long time.<br />
5CSL0-06B<br />
378 Controller accessories
5CSL0-06B Wireless remote controller<br />
Function's detail<br />
Models : PQWRHSF0<br />
The remote control transmits the signals to the system.<br />
5<br />
6<br />
4<br />
2<br />
7<br />
11<br />
8<br />
13<br />
15<br />
ON OFF<br />
Operation Mode<br />
CANCEL<br />
SET<br />
AUTO CLEAN<br />
Cooling Operation<br />
Auto Operation or Auto Changeover<br />
Healthy Dehumidification Operation<br />
Heating Operation<br />
Signal transmitter<br />
1<br />
3<br />
10<br />
9<br />
12<br />
14<br />
16<br />
Flip-up door<br />
(opened)<br />
• Cooling Model( ), Heat Pump Model( )<br />
17<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
8.<br />
9<br />
10.<br />
11.<br />
12.<br />
13.<br />
14.<br />
15.<br />
16.<br />
17.<br />
START/STOP BUTTON<br />
Operation starts when this button is pressed and stops<br />
when the button is pressed again.<br />
Operation mode selection button<br />
Used to select the operation mode.<br />
ROOM TEMPERATURE SETTING BUTTONS<br />
Used to select the room temperature.<br />
INDOOR FAN SPEED SELECTOR<br />
Used to select fan speed in four steps<br />
low, medium, high and CHAOS.<br />
JET COOL<br />
Used to start or stop the speed<br />
cooling. (Speed cooling operates<br />
super high fan speed in cooling mode.)<br />
CHAOS SWING BUTTON<br />
Used to stop or start louver movement and set the desired<br />
up/down airflow direction.<br />
ON/OFF TIMER BUTTONS<br />
Used to set the time <strong>of</strong> starting and stopping operation.<br />
TIME SETTING BUTTONS<br />
Used to adjust the time.<br />
TIMER SET/CANCEL BUTTON<br />
Used to set the timer when the desired time is obtained and<br />
to cancel the Timer operation.<br />
SLEEP MODE AUTO BUTTON<br />
Used to set Sleep Mode Auto operation.<br />
AIR CIRCULATION BUTTON<br />
Used to circulate the room air without cooling or heating.<br />
ROOM TEMPERATURE CHECKING BUTTON<br />
Used to check the room temperature.<br />
PLASMA(OPTIONAL)<br />
Used to start or stop the <strong>pl</strong>asma-purification function.<br />
HORIZONTAL AIRFLOW DIRECTION CONTROL<br />
BUTTON (NOT ON ALL MODELS)<br />
Used to set the desired horizontal airflow direction.<br />
RESET BUTTON<br />
Used prior to resetting time or after re<strong>pl</strong>acing batteries.<br />
2nd F Button<br />
Used prior to using modes printed in blue at the bottom <strong>of</strong><br />
buttons.<br />
AUTO CLEAN(OPTIONAL)<br />
Used to set Auto Clean mode.<br />
Controller accessories 379
Wireless remote controller<br />
Models : AHWRHD<br />
3<br />
4<br />
5<br />
6<br />
Flip-up door(opened)<br />
ON OFF<br />
SET CANCEL<br />
Signal transmitter<br />
1<br />
7<br />
2<br />
8<br />
9<br />
10<br />
11<br />
5CSL0-06B<br />
1. Operation dis<strong>pl</strong>ay<br />
Dis<strong>pl</strong>ays the operation conditions.<br />
2. Start/Stop button<br />
Operation starts when this button is pressed and stops<br />
when the button is pressed again.<br />
3. Operation mode selection button<br />
Used to select the operation mode.<br />
4. on/<strong>of</strong>f timer buttons<br />
Used to set the time <strong>of</strong> starting and stopping operation.<br />
5. Time setting buttons<br />
Used to adjust the time.<br />
6. timer set/cancel buttons<br />
Used to set the timer when the desired time is obtained<br />
and to cancel the Timer operation.<br />
7. Air flow direction start/stop button<br />
Used to stop or start louver movement and set the<br />
desired up/down airflow direction.<br />
8. Sleep mode auto button<br />
Used to set Sleep Mode Auto operation.<br />
9. Air circulation button<br />
Used to circulate the room air without cooling or heating<br />
(turns indoor fan on/<strong>of</strong>f).<br />
10. room temperature checking button<br />
Used to check the room temperature.<br />
11. Reset button<br />
Used prior to resetting time or after re<strong>pl</strong>acing batteries.<br />
380 Controller accessories
5CSL0-06B Wireless remote controller<br />
Models : AHWRHS<br />
Signal transmitter<br />
Transmits the signals to the signal receptor.<br />
1<br />
4<br />
3<br />
5<br />
6<br />
A/CL<br />
9<br />
2<br />
7<br />
8<br />
1. FAN operation button<br />
Used to circulate room air without cooling or heating.<br />
2. Cooling operation button<br />
3. S<strong>of</strong>t dry operation button<br />
Used to dehumidify without overcooling.<br />
4. Heating operation button<br />
(Heat pump model only)<br />
5. Timer set button<br />
Used to set the timer when the desired time is obtained.<br />
Then the wired remote controller is set up to 24 hours by<br />
an hour but the wireless remote controller is set up to 7<br />
hours by an hour. Therefore, if you want to set over 7<br />
hours, use the wired remote controller.<br />
6. Fan speed button<br />
Used to set the desired fan speed.<br />
7. On/Off button<br />
Operation starts when this button is pressed, and stops<br />
when the button is pressed again.<br />
8. Set temperature button<br />
Used to set the temperature when the desired temperature<br />
is obtained<br />
9. Auto operation button<br />
Controller accessories 381
Sim<strong>pl</strong>e wired remote control<br />
1.2 Sim<strong>pl</strong>e wired remote controller<br />
Models : PQRCUCA0<br />
Picture:<br />
Ap<strong>pl</strong>icable models<br />
Cassette, duct and ceiling and floor<br />
Functional control<br />
Dimension<br />
PQRCHCS0<br />
Defrost Preheat Out door<br />
Slo<br />
Lo<br />
Med<br />
Hi<br />
Po<br />
Cooling Heating Auto Dry Fan<br />
MODE<br />
FAN<br />
SPEED<br />
Room Temp<br />
Total on<br />
Central Run<br />
120mm<br />
1<br />
2<br />
3<br />
4<br />
5<br />
PQRCHCS0<br />
Defrost Preheat Out door<br />
Slo<br />
Room Temp<br />
Lo<br />
Total on<br />
Med<br />
Hi<br />
Po<br />
Central Run<br />
Cooling Heating Auto Dry Fan<br />
MODE<br />
70mm<br />
FAN<br />
SPEED<br />
Functional description:<br />
13.5mm<br />
5CSL0-06B<br />
1. Sim<strong>pl</strong>e design.<br />
2. Sim<strong>pl</strong>e & easy use.<br />
3. Memorize data(operation data) in case <strong>of</strong> power failure.<br />
4. ON/OFF , Temperature setting, room temperature dis<strong>pl</strong>ay,<br />
Air flow control, lock setting, Fault diagnosis function,<br />
operation mode setting, basic functions.<br />
5. Easy address setting with central control.<br />
6. Operation LED is on during operation.<br />
1. Operation Dis<strong>pl</strong>ay Panel<br />
2. On/<strong>of</strong>f Function<br />
3. Fan Speed Button<br />
4. Temperature Control Button<br />
5. Mode Selection Check Button<br />
382 Controller accessories
5CSL0-06B Sim<strong>pl</strong>e wired remote control<br />
Installation method:<br />
1 Put the installation paper on the <strong>pl</strong>ace and determine the position and height <strong>of</strong> the fixing screws <strong>of</strong> the wired remote controller.<br />
• Refer to the printed side <strong>of</strong> the installation paper.<br />
2 Plug the connecting cable into the indoor unit.<br />
• The product is being shipped with the cable connected only to the remote controller.<br />
Fix the connecting cable with the cable rack.<br />
Side <strong>of</strong><br />
remote Controller<br />
The position <strong>of</strong> the fixing screws<br />
Side <strong>of</strong><br />
Indoor Unit<br />
3 Remove the installation paper before installing the remote controller so that it can fit at the right <strong>pl</strong>ace.<br />
Fixing the<br />
remote controller<br />
Main frame<br />
* Do not embed the remote controller into the wall. (It may cause the breakdown <strong>of</strong> the temperature sensor.)<br />
* If you want to install a number <strong>of</strong> remote controller at the same <strong>pl</strong>ace in a vertical line, install them at regular intervals <strong>of</strong><br />
2cm. (It may cause the breakdown <strong>of</strong> the temperature sensor.)<br />
* Do not install the cable with a distance <strong>of</strong> 30 m or longer. (This can cause communication error.)<br />
* When installing the cable, check whether the connector between the remote controller and the product is installed properly.<br />
The connector will not be connected when installed in opposite sides.<br />
o Sup<strong>pl</strong>y the power after connecting wired remote controller.<br />
When you need to change wired remote controller, switch <strong>of</strong>f the main power and change it.<br />
If the wired remote controller is changed before switching <strong>of</strong>f the main power, the option function <strong>of</strong> the indoor unit can't<br />
be used. (option function like "slow" fan speed selection)<br />
Controller accessories 383<br />
2CM<br />
Main<br />
indoor unit<br />
CN-M C CN-ZONE<br />
J15<br />
C01K<br />
J14<br />
CN-REMO<br />
IC01A<br />
CN-DISP<br />
LO1K<br />
LO1D C07D<br />
LO2K<br />
Red Yellow Brown
Deluxe wired remote controller<br />
1.3 Deluxe wired remote controller<br />
Models : PQRCUDS0<br />
Picture:<br />
Ap<strong>pl</strong>icable models<br />
Cassette, duct and ceiling and floor<br />
Functional control<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
11<br />
12<br />
13<br />
14<br />
15<br />
16<br />
17<br />
18<br />
19<br />
20<br />
5CSL0-06B<br />
Functional Description:<br />
1. Big LCD panel which can dis<strong>pl</strong>ay various information.<br />
2. Deluxe touch panel.<br />
3. Memorize data(operation data) in case <strong>of</strong> power failure.<br />
4. ON/OFF,Temperature setting, room temperature dis<strong>pl</strong>ay,<br />
5. Air flow control, lock setting,reservation function,<br />
6. Fault diagnosis function, operation mode setting, basic<br />
functions.<br />
7. Easy address setting with central control.<br />
8. Deluxe with LCD back light ap<strong>pl</strong>ied<br />
9. Vane control & child lock, optimum air control as deluxe<br />
function<br />
10. Back light LED is on during operation.<br />
1. Operation Dis<strong>pl</strong>ay Panel<br />
2. Room Temperature Button<br />
3. Fan Speed Button<br />
4. Fan/Plasma/Swirl Swing Button<br />
5. Automatic / Power Saving Vane Control Button<br />
6. Timer Mode Button<br />
7. Date Selection Button<br />
8. Hour/Minute Button<br />
9. Mode Selection Button<br />
10. On/Off Button for reservation<br />
11. Temperature Control Button<br />
12. On/Off Button<br />
13. Special Function Button<br />
14. Dehumidification/ Heater/ Go-out Button<br />
15. Sub Function Button<br />
16. Easy Reservation Button<br />
17. Cancel Button<br />
18. Heating/Ventilation/Elevation Grill Button<br />
19. Setting Button<br />
20. Cooling / Auto Swing / Child Lock Button<br />
384 Controller accessories
5CSL0-06B Deluxe wired remote controller<br />
Installation method:<br />
1 Put the installation paper on the <strong>pl</strong>ace and determine the position and height <strong>of</strong> the fixing screws <strong>of</strong> the wired remote controller.<br />
• Refer to the printed side <strong>of</strong> the installation paper.<br />
The position <strong>of</strong> the fixing screws<br />
2 Plug the connecting cable into the indoor unit.<br />
• The product is being shipped with the cable connected only to the remote controller. Put each cable to the remote controller<br />
according to the color match<br />
Yellow<br />
Yellow<br />
Side <strong>of</strong><br />
remote Controller<br />
Side <strong>of</strong><br />
Indoor Unit<br />
Main frame<br />
3 Remove the installation paper before installing the remote controller so that it can fit into the right <strong>pl</strong>ace.<br />
CN-M C CN-ZONE<br />
J15<br />
Fixing the<br />
remote controller<br />
Be careful not to alter the colors<br />
<strong>of</strong> the remote controller<br />
connection cables.<br />
C01K<br />
J14<br />
CN-REMO<br />
IC01A<br />
CN-DISP<br />
LO1K<br />
LO1D C07D<br />
Red Yellow Brown<br />
LO2K<br />
Fixing the<br />
connecting cable<br />
* When installing the wired remote controller, do not install it so that it is buried to the wall. (This can cause error in the<br />
temperature sensor)<br />
* When installing multi<strong>pl</strong>e wired remote controllers horizontally in one location, leave a minimum distance apart (2cm).<br />
(This can cause error in the temperature sensor)<br />
* Do not install the cable with a distance <strong>of</strong> 50 m or longer. (This can cause communication error.)<br />
* When installing the cable, check whether the connector between the remote controller and the product is installed properly.<br />
The connector will not be connected when installed in opposite sides.<br />
❏ Sup<strong>pl</strong>y the power after connecting wired remote controller.<br />
When you need to change wired remote controller, switch <strong>of</strong>f the main power and change it Before switch <strong>of</strong>f the main<br />
power if changed the wired remote controller , you can't use the option function <strong>of</strong> the indoor unit.<br />
Controller accessories 385
Hotel use remote controller<br />
1.4 Hotel use remote controller<br />
Models : PQRCFCS0<br />
Picture:<br />
Ap<strong>pl</strong>icable models<br />
Cassette, duct and ceiling and floor<br />
Functional control<br />
PQRCHCS0<br />
Defrost Preheat Out door<br />
Slo<br />
Lo<br />
Med<br />
Hi<br />
Po<br />
Cooling Heating Auto Dry Fan<br />
MODE<br />
FAN<br />
SPEED<br />
Room Temp<br />
Total on<br />
Central Run<br />
1<br />
2<br />
3<br />
4<br />
5<br />
Functional description:<br />
5CSL0-06B<br />
Can control one or multi indoor units which have been<br />
installed at remote areas with same function by same controller<br />
at same time<br />
1. Sim<strong>pl</strong>e design.<br />
2. Sim<strong>pl</strong>e & easy use.<br />
3. Memorize data(operation data) in case <strong>of</strong> power failure.<br />
4. ON/OFF , Temperature setting, room temperature dis<strong>pl</strong>ay,<br />
Air flow control, lock setting, Fault diagnosis function,<br />
operation mode setting, basic functions.<br />
5. Easy address setting with central control.<br />
6. Operation LED is on during operation.<br />
7. Operation mode setting can be done by central control<br />
1. Operation Dis<strong>pl</strong>ay Panel<br />
2. On/<strong>of</strong>f Function<br />
3. Fan Speed Button<br />
4. Temperature Control Button<br />
5. Room temperature button<br />
386 Controller accessories
5CSL0-06B Hotel use remote controller<br />
Dimension<br />
Operation<br />
1. LCD Panel to show various information.<br />
2. Can check indoor operation status by Key.<br />
3. Memorize data(operation data) in case <strong>of</strong> power failure.<br />
4. ON/OFF , Temperature setting, room temperature dis<strong>pl</strong>ay, Air flow control, lock setting, Fault diagnosis function, operation<br />
mode setting, basic functions, reservation function, Clock function.<br />
5. Easy address setting with central control.<br />
NOTE<br />
120mm<br />
PQRCHCS0<br />
Defrost Preheat Out door<br />
Slo<br />
Room Temp<br />
Lo<br />
Total on<br />
Med<br />
Hi<br />
Po<br />
Central Run<br />
Cooling Heating Auto Dry Fan<br />
MODE<br />
70mm<br />
FAN<br />
SPEED<br />
13.5mm<br />
1. Two types <strong>of</strong> controller CST/DUCT.<br />
2. Can control one or multi indoor units which have been installed at remote areas with same function by same controller at<br />
same time.<br />
Controller accessories 387
Zone Control<br />
1.5 Zone Control<br />
Models : ABZCA<br />
Picture<br />
Zone Control<br />
sub PCB<br />
Ap<strong>pl</strong>icable models<br />
Ceiling concealed duct<br />
Accessory<br />
• Factory Sup<strong>pl</strong>ied :<br />
5CSL0-06B<br />
- Zone Control PCB............................................................................................................................................................1EA<br />
- Trans................................................................................................................................................................................1EA<br />
- Case ................................................................................................................................................................................1EA<br />
- Cover ...............................................................................................................................................................................1EA<br />
- Main lead wires................................................................................................................................................................1EA<br />
- Screws .............................................................................................................................................................................4EA<br />
- Holder ..............................................................................................................................................................................4EA<br />
- Installation Manual................................................................................................................................................................1<br />
• Purchased Locally :<br />
- Damper Motor<br />
- Thermostat<br />
- Damper<br />
ROOM1 Thermostat<br />
Damper Motor<br />
Damper Motor<br />
ROOM3 Thermostat<br />
ROOM2 Thermostat<br />
Damper Motor<br />
Damper Motor<br />
ROOM4 Thermostat<br />
Functional Description:<br />
1) Operation Summary<br />
A device which senses temperature <strong>of</strong> each zone controls<br />
operation <strong>of</strong> each diffuser,so temperature <strong>of</strong> each zone<br />
can be controlled.<br />
2) Specific Operation<br />
- If every zone (diffuser) is closed, Comp and outer fan<br />
become turned <strong>of</strong>f to protect compressor.<br />
* Zone controller requires diffuser temperatures and controllers<br />
available locally.<br />
3) Operating Scene<br />
• The temperature <strong>of</strong> all zones are controlled individually<br />
(makes energy savings) controlled by the signal <strong>of</strong> every<br />
zones in duct system (By connecting the thermostat<br />
and VAV Diffuser to Main PCB,comp. & fan)<br />
• Diffuser and Thermostat are locally sourced Connected<br />
to Another Apparatus, Control it Freely.<br />
388 Controller accessories
5CSL0-06B Zone Control<br />
Installation method:<br />
• Connect main lead wires between main PCB and Zone Control.<br />
• Connect thermostat to Zone Control according to thermostat maker's manuals.<br />
• Connect Damper Motor to Zone Control according to Damper Motor maker's manuals.<br />
• Wiring also depends upon the type <strong>of</strong> the damper actuators.<br />
• Spring Return Damper Actuators<br />
Trans : 12VA<br />
(24V/130mA*4)<br />
Trans<br />
Main<br />
PCB<br />
Indoor Unit<br />
Zone<br />
Controller<br />
PCB<br />
CH1<br />
CH2<br />
CH3<br />
CH4<br />
COM<br />
COM<br />
COM<br />
COM<br />
AC 24V<br />
24V<br />
24V<br />
Power Input<br />
24V<br />
AC220~240V 50/60Hz<br />
Thermostat #1<br />
Thermostat #2<br />
Thermostat #3<br />
Thermostat #4<br />
• Non Spring Return Damper Actuators<br />
Trans : 12VA<br />
(24V/130mA*4)<br />
Trans<br />
Main<br />
PCB<br />
Indoor Unit<br />
Zone<br />
Controller<br />
PCB<br />
AC(L) AC(N)<br />
CH1<br />
CH2<br />
CH3<br />
CH4<br />
COM<br />
COM<br />
COM<br />
COM<br />
AC 24V<br />
24V<br />
24V<br />
Power Input<br />
24V<br />
AC(L) AC(N)<br />
AC220~240V 50/60Hz<br />
By Pass Damper System :-<br />
24 VCA<br />
power sup<strong>pl</strong>y<br />
HVAC<br />
Thermostat #1<br />
Thermostat #2<br />
Thermostat #3<br />
Thermostat #4<br />
By-pass damper<br />
Damper<br />
Motor<br />
#1<br />
Damper<br />
Motor<br />
#2<br />
Damper<br />
Motor<br />
#3<br />
Damper<br />
Motor<br />
#4<br />
Controller accessories 389<br />
N<br />
Damper<br />
Motor<br />
#1<br />
N<br />
L L L L<br />
N N N<br />
S S S S<br />
Damper<br />
Motor<br />
#2<br />
Damper<br />
Motor<br />
#3<br />
N N N<br />
L : Live<br />
N : Neutral<br />
S : Signal<br />
Return Sup<strong>pl</strong>y<br />
40 VA<br />
transformer<br />
NC NO<br />
Pressure controller<br />
Closed<br />
Open<br />
Common<br />
2 3<br />
1<br />
Static<br />
pressure<br />
control<br />
3-channel damper motor<br />
Damper<br />
Motor<br />
#4<br />
To maintain an adequate flow <strong>of</strong> air and static pressure through the HVAC system, a by-pass system can be used that is<br />
equipped with a motorized damper and a static pressure control.
Zone Control<br />
Installation Procedure:<br />
5CSL0-06B<br />
• The control should be mounted to control panel using 4 screws sup<strong>pl</strong>ied.<br />
• Fasten it to any holes on control panel as long as there is enough space to install. If necessary drill holes to install on proper<br />
position.<br />
• When drilling, ensure that metal f does not foul any electronic components.<br />
* Central<br />
Contr oller<br />
Wiring Diagram:<br />
* Central<br />
Sub PCB<br />
** Wir ed<br />
Remote<br />
Contr oller<br />
**Main Pcb<br />
** Dis<strong>pl</strong>ay PCB<br />
*RF<br />
Remote<br />
Contr oller<br />
Indoor Unit<br />
When the area dampers open or close, the static pressure control will open or close the by-pass damper so as to maintain<br />
the adequate static pressure. Dimensions <strong>of</strong> the by-pass damper depends on the cooling capacity <strong>of</strong> the unit.<br />
Btu/h Size <strong>of</strong> the by-pass (ø)<br />
36K 250 mm<br />
42K 250 mm<br />
48K 300 mm<br />
60K 300 mm<br />
91K 350 mm<br />
120K 350 mm<br />
Remarks:<br />
• Turn <strong>of</strong>f the Power before installation or maintenance.<br />
Array <strong>of</strong> PCB & Controllers Local sourcing components<br />
* Zone<br />
Contr oller<br />
Sub Pcb<br />
AC 24V<br />
Transformer<br />
Outdoor Unit<br />
ZONE CONTROLLER WIRING DIAGRAM<br />
Thermostat #1<br />
Thermostat #2<br />
Thermostat #3<br />
Thermostat #4<br />
In case <strong>of</strong> 220V Damper,<br />
attach AC 24V Relay<br />
390 Controller accessories<br />
Relay<br />
Relay<br />
Relay<br />
Relay<br />
Damper<br />
#1<br />
Damper<br />
#2<br />
Damper<br />
#3<br />
Damper<br />
#4
5CSL0-06B Dry contact module<br />
1.6 Dry contact module<br />
Models : PQDSA [Without case], PQDSB [With case]<br />
Picture:<br />
PQDSA<br />
Accessory:<br />
PQDSA<br />
• Dry Contact PCB ..........................................................1EA<br />
• Installation Manual .......................................................1EA<br />
• Lead Wire Assembly ....................................................4EA<br />
Ap<strong>pl</strong>icable Models<br />
• LGAP ap<strong>pl</strong>ication models<br />
Installation Procedure:<br />
Installation steps for single product<br />
PQDSB<br />
• Dry Contact PCB 1EA<br />
• Case 1EA<br />
• Installation Manual 1EA<br />
• Lead Wire Assembly 4EA<br />
1 . Connect CN-CC with Main PCB by the cable(provided)<br />
- Connection <strong>of</strong> Dry contact only - Connection <strong>of</strong> Dry contact & LG Central Controller<br />
MAIN<br />
PCB<br />
CN-CC CN-CC<br />
PQDSB<br />
DRY CONTACT<br />
SUB PCB<br />
2 1 1<br />
4 4<br />
3 3<br />
2 2<br />
1 1<br />
AC 220V<br />
1<br />
3 4 5 6<br />
Controller accessories 391<br />
MAIN<br />
PCB<br />
2<br />
1 CN-POWER : AC 220V Connector<br />
2 CN-CC : MAIN PCB Connector<br />
3 CN_DRY (L) : DRY CONTROLLER Connector<br />
4 CN_DRY ( SIG ) : DRY CONTROLLER Connector<br />
5 CN_DRY (ERROR CHECK) : ERROR Check<br />
Dis<strong>pl</strong>ay Connector<br />
6 CN_DRY( OPER STATE): Operation Dis<strong>pl</strong>ay<br />
Connector<br />
Connection PCB<br />
(6871A30056A)<br />
CN-CC CN-CC<br />
S1<br />
BR1<br />
ON<br />
L1 2 3 4<br />
TANS01Y<br />
C03Y<br />
SWITCH<br />
U03Y<br />
OSC01B<br />
L02D<br />
L01D<br />
U04Y<br />
C04Y<br />
U02Y<br />
C01A<br />
LED1<br />
LED01G<br />
LED02G<br />
LED03G<br />
IC01A<br />
CN_COMM<br />
ZNR01Y<br />
DRY CONTACT<br />
SUB PCB<br />
2 1 1<br />
4 4<br />
3 3<br />
2 2<br />
1 1<br />
AC 220V<br />
PI485 PCB : Special purchase for<br />
Central Control<br />
(Ex : PHNFP14A0 or PSNFP14A0...)
Dry contact module<br />
Installation steps for muiti product<br />
1 . Connect CN_DRY with Control Unit .<br />
(Fix SUB PCB into the proper location.)<br />
- To ap<strong>pl</strong>y power source through PCB - To ap<strong>pl</strong>y power source from the outside<br />
DRY CONTACT<br />
SUB PCB<br />
CN-CC<br />
User guide<br />
Function<br />
RY1<br />
RY2<br />
4 4<br />
3 3<br />
2 2<br />
1 1<br />
2<br />
2 1 N L<br />
1<br />
INPUT<br />
AC 220V<br />
Operation Dis<strong>pl</strong>ay<br />
Error Check Dis<strong>pl</strong>ay<br />
Dry contact<br />
Controller<br />
DRY CONTACT<br />
SUB PCB<br />
Dry contact<br />
Controller<br />
5CSL0-06B<br />
392 Controller accessories<br />
CN-CC<br />
RY1<br />
RY2<br />
2<br />
2 1 N L<br />
1<br />
4 4<br />
3 3<br />
2 2<br />
1 1<br />
AC 220V<br />
Operation Dis<strong>pl</strong>ay<br />
Error Check Dis<strong>pl</strong>ay<br />
It gives a selection whether to turn ON the unit directly or not from the external source (such as key holder in hotel rooms).<br />
The selection can be made by pressing Cancel button <strong>of</strong> the wireless remote controller 3 times within 3 minutes <strong>of</strong> starting<br />
the unit facing it towards the unit (This function availability depends on indoor unit model type.)<br />
1. Normal mode (Factory set)<br />
• Not to turn ON the unit directly from the external source.<br />
On inserting the key inside the key holder, it activates the system.<br />
Later on , the unit can be turned ON by the remote controller.<br />
2.Automatic mode<br />
• To turn ON the unit directly from the external source<br />
On inserting the key inside the key holder, it automatically turns<br />
ON the air conditioner. So no need to use remote controller.<br />
❈ However the unit can be turned <strong>of</strong>f directly if the key is taken out <strong>of</strong> the key holder for both cases.<br />
CAUTION<br />
• In case <strong>of</strong> power failure the air conditioner will resume its similar operation before the power failure.<br />
• In case power comes again after a power failure. Auto restart the unit auto magically operates to the previous operation<br />
conditions.
5CSL0-06B Branch kit<br />
2. Mechanical accessories<br />
2.1 Branch kit<br />
Models : PMUB11A, PMUB111A, PMUB1111A<br />
Picture<br />
Features<br />
Connectable <strong>of</strong><br />
indoor units<br />
Models<br />
2 Units PMUB 11A<br />
3 Units<br />
4 Units<br />
PMUB 111A<br />
PMUB 1111A<br />
Gas pipe Liquid pipe<br />
Gas pipe Liquid pipe<br />
(1:1) (1:1)<br />
(1:1:1) (1:1:1)<br />
(1:1:1:1) (1:1:1:1)<br />
Mechanical accessories 393
Branch kit<br />
Branch kit<br />
Between units are the required Branch kits mentioned, that are necessary to install the combination.<br />
C<br />
Indoor Classification<br />
2 Units<br />
3 Units<br />
4 Units<br />
A<br />
Model Name<br />
PMUB11A<br />
PMUB111A<br />
PMUB1111A<br />
a b c<br />
a b<br />
Type 1 Type 2<br />
B<br />
D<br />
Capacity Ratio(%)<br />
50:50 (1:1)<br />
33:33:33 (1:1:1)<br />
25:25:25:25(1:1:1:1)<br />
5CSL0-06B<br />
Unit : mm (inch)<br />
394 Mechanical accessories<br />
(I.D)<br />
ⓐ ⓑ ⓒ Type<br />
Ⓐ Ø15.88(5/8) Ø19.05(3/4) Ø25.4(1) 1<br />
Ⓑ<br />
Ø9.52(3/8)<br />
Ø12.7(1/2)<br />
Ø12.7(1/2)<br />
Ø15.88(5/8)<br />
- 2<br />
Ⓒ Ø6.35(1/4) Ø9.52(3/8) - 2<br />
Ⓓ Ø9.52(3/8) Ø12.7(1/2) - 2
5CSL0-06B<br />
2.2 Drain pump<br />
Ceiling Concealed Duct<br />
Accessory Model Name D, F Chassis G, H & R Chassis E Chassis<br />
ABDPD ABDPG ABDPE<br />
Functional Description:<br />
• To remove the condensed water from the indoor unit.<br />
• In some <strong>of</strong> the <strong>pl</strong>aces where natural drainage is not possible Drain Pump is very useful to remove condensed water.<br />
Picture:<br />
Accessory:<br />
Factory Sup<strong>pl</strong>ied Parts<br />
For D, E & F Chassis Models<br />
- Drain Pump Assembly<br />
(AC220-240,50/60Hz,400CMM).........................1EA<br />
- Elbow (ø32)........................................................1EA<br />
- Hose...................................................................1EA<br />
- Tie Wrap ...........................................................2EA<br />
- Screw ...............................................................10EA<br />
- Rubber ...............................................................1EA<br />
- Installation Manual .............................................1EA<br />
For G, H & R Chassis Models :<br />
- Drain Pump Assembly<br />
(AC220-240,50/60Hz,400CMM).........................1EA<br />
- Screw .................................................................4EA<br />
- Cap ....................................................................1EA<br />
- Installation Manual .............................................1EA<br />
ABDPD/ABDPE ABDPG<br />
Parts needed for servicing<br />
(Factory Sup<strong>pl</strong>ied)<br />
For D, E & F Chassis Models :<br />
Part Name Part No.<br />
Water Pump 5858A10001L<br />
Switch Assy, Float 6601A20001E<br />
For G, H & R Chassis Models :<br />
Part Name Part No.<br />
Water Pump 5858A10001L<br />
Switch Assy, Float 6601A20001E<br />
Drain pump<br />
Mechanical accessories 395
Drain pump 5CSL0-06B<br />
Installation procedure<br />
For D,E&F Chassis Models:<br />
Step 1. Separate the filter and Open the top cover.<br />
Step 2. Assemble the drain pump assembly and Attach the elbow to the side panel. Tighten 4 screws to the channel.<br />
Tighten 2 screws to the Side panel.<br />
Step 3. Connect the hose and tie wrap and Connect two lead wires to control box. Connect two lead wires to control box,<br />
One wire is for float switch and other Wire is for power sup<strong>pl</strong>y to drain pump.<br />
.<br />
Step 4. Assemble the top cover.<br />
396 Mechanical accessories
5CSL0-06B<br />
Installation procedure<br />
For G, H & R Chassis Models:<br />
Step 1. Separate the filter and Open the top cover.<br />
Drain pump<br />
Step 2. Remove the knock-out from the side panel and Assemble the drain pump assembly. Tighten 4 screws to the Side<br />
Panel.<br />
Step 3. Connect two lead wires to control box and Close the drainage hole with the provided cap. Connect two lead wires<br />
to control box (One wire is for float switch and other Wire is for power sup<strong>pl</strong>y to drain pump.)<br />
Step 4. Assemble the top cover and insert the filter.<br />
Mechanical accessories 397
Drain pump 5CSL0-06B<br />
Wiring diagram:<br />
For D, E & F chassis models<br />
For G & H Chassis Models :<br />
TO OUTDOOR UNIT<br />
TO OUTDOOR UNIT<br />
1(L) 2(N) 4<br />
3 5<br />
TERMINAL<br />
BLOCK<br />
1(L) 2(N) 4<br />
3 5<br />
TERMINAL<br />
BLOCK<br />
T/B<br />
BR<br />
BL<br />
RD<br />
BK<br />
GN/YL<br />
BR<br />
BL<br />
RD<br />
BK<br />
BL<br />
GN/YL<br />
VENTILATOR<br />
INDOOR ELECTRIC CIRCUIT<br />
INDOOR<br />
MOTOR<br />
398 Mechanical accessories<br />
COMP<br />
BR<br />
YL<br />
FUSE<br />
250V10A<br />
OR<br />
RD<br />
BL<br />
BK<br />
4 WAY<br />
GN/YL<br />
DRAIN<br />
PUMP<br />
BL<br />
BL<br />
Drain Pump Assy<br />
ZONE<br />
CONTROL<br />
INDOOR ELECTRIC CIRCUIT<br />
FUSE<br />
250V 8A<br />
COMP<br />
YL<br />
BR<br />
OR<br />
A/CL<br />
UNIT<br />
INDOOR<br />
MOTOR<br />
BR<br />
BK<br />
4 WAY<br />
GN/YL<br />
TRIAC<br />
VENT<br />
TELECONTROL/<br />
CENTRAL CONTROL<br />
DRAIN<br />
PUMP<br />
BL<br />
BL<br />
Drain Pump Assy<br />
ZONE<br />
CONTROL<br />
TEMP.<br />
THERMISTOR<br />
TEMP.<br />
THERMISTOR<br />
PIPE<br />
THERMISTOR<br />
FLOAT S/W<br />
REMOTE<br />
CONTROL<br />
PIPE<br />
THERMISTOR<br />
FLOAT S/W<br />
REMOTE<br />
CONTROL<br />
OPTION
5CSL0-06B<br />
Remarks<br />
For D, E, F, G, H & R Chassis Models<br />
• Possible drain-head height is up to 700mm. so, installation must be<br />
below 700mm.<br />
• Keep the drain hose inclined downward with a slope <strong>of</strong> 1/50~1/100.<br />
• Prevent upward or reverse flow.<br />
- To prevent condensate forming over the drain pipe minimum 5mm thick insulation should be ap<strong>pl</strong>ied.<br />
- Upward rounding is not allowed.<br />
- Be sure that there should not be any leakage<br />
- after closing the drainage hole with the cap.<br />
Unit<br />
1/50~1/100<br />
Drainage Hole<br />
• Disconnect the power sup<strong>pl</strong>y before installation & maintenance.<br />
• Check the drain pump for normal operation and abnormal noise after electrical wiring.<br />
Drain Pipe<br />
Drain Pump<br />
MAX 700mm<br />
Drain pump<br />
1/50~1/100<br />
Mechanical accessories 399<br />
Elbow<br />
Drain pump<br />
Thermal insulator<br />
(Local sup<strong>pl</strong>y)<br />
Drainage pipe<br />
(Local sup<strong>pl</strong>y)<br />
Cap
Air guide 5CSL0-06B<br />
2.3 Air guide<br />
Models : PQAGA.<br />
Picture:<br />
Accessory:<br />
Air Guide........................................................................1EA<br />
Dimension<br />
Installation Procedure:<br />
587.6<br />
372.5<br />
1. Fix the air guide unit on the top <strong>of</strong> the outdoor unit as shown in the figure.<br />
600mm<br />
390<br />
Ap<strong>pl</strong>icable Models<br />
• Multi-V <strong>pl</strong>us chassis; UQ, UY, UW<br />
• Multi F DX chassis; UY, UW<br />
• Single A; UY, UW<br />
400 Mechanical accessories<br />
125<br />
2400mm<br />
723.5<br />
950mm Air guide<br />
950mm<br />
Functional Description:<br />
• It is an air guide that specially fits the Outdoor design.<br />
• Air discharge can be changed by a sim<strong>pl</strong>e installation.<br />
• With one outdoor unit top discharge and front discharge<br />
are available simultaneously.
5CSL0-06B<br />
2.4 Cassette cover<br />
Models : PTDCQ, PTDCM<br />
Picture:<br />
Functional Description:<br />
Maintains the ceiling elegance.<br />
• Covers the side area <strong>of</strong> cassette.<br />
• Gives elegant looks.<br />
• Light weight..<br />
• Suitable when false ceiling is unavailable.<br />
Ap<strong>pl</strong>icable Models:<br />
PTDCQ : UT09, UT12, UT18 TR/TQ CHASSIS<br />
PTDCM : UT24 ~ UT60 TP/TN/TM CHASSIS<br />
Cassette cover<br />
Mechanical accessories 401
Air Conditioner<br />
20 Yeouido-dong, Yeongdeungpo-gu,<br />
Yeouido P.O.Box 335 Seoul,<br />
150-721, Korea.<br />
http://www.lgeaircon.com<br />
All rights reserved<br />
Printed in Korea December/2010<br />
The specifications, designs, and<br />
information in this brochure are subject to<br />
change without notice.<br />
P/No.: 3828A20576H<br />
The air conditioners manufactured by LG have received ISO9001 certificate for<br />
quality assurance and ISO14001 certificate for environmental management system.