Features 5CSL0-06B<br />

• Group Control<br />

1) Operation Summary<br />

- Where several products are linked, one specific control<br />

device can control a specific number <strong>of</strong> products.<br />

2) Specific Operation<br />

- Connecting line is linked to each <strong>of</strong> the indoor equipments<br />

for communication.<br />

A specific control device is connected to each <strong>of</strong> them<br />

and this control device can control the same function.<br />

- Group control function is enabled by dip switches in the<br />

wired remote control.<br />

At this time, the main system will not respond in order to<br />

prevent data collision.<br />

- While executing group control command, use the random<br />

data(0-3minutes) in the main body <strong>of</strong> indoor equipment<br />

for limiting starting current.<br />

- Control device can control up to 16 indoor equipments.<br />

• Cassette Cover<br />

(Accessory : PTDCQ / PTDCM)<br />

Maintains the ceiling elegance.<br />

- Covers the side area <strong>of</strong> cassette.<br />

- Gives elegant looks.<br />

- Light weight.<br />

- Suitable when false ceiling is unavailable.<br />

• Auto Changeover<br />

With reverse cycle models, the air conditioner will switch<br />

automatically from cooling to heating modes depending on<br />

the set temperature.<br />

• Initial Setting Temp :18 °C:<br />

(Memory the final setting temp)<br />

• Control <strong>of</strong> setting temp.<br />

Wired Remoted Controller:18~30 °C<br />

Reset Button in indoor unit: finally memorized temp.<br />

Wireless Remoted Controller: 23~27<br />

InsideTemp<br />

24 General information<br />

Temp<br />

+2<br />

+1<br />

+0.5<br />

Setting<br />

Temp<br />

-0.5<br />

-1<br />

-2<br />

COMP ON <strong>of</strong>f ON <strong>of</strong>f <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f ON <strong>of</strong>f<br />

Indoor FAN Setting -Low Setting -Low Stop Setting Low stop Setting -Low stop Setting Low<br />

Cycle Cooling<br />

Heating<br />

Cooling