Specifications 5CSL0-06B<br />

Indoor unit type Ceilling Concealed Duct - High Static<br />

Model ABNH606RLAD [UB60 NRD]<br />

Power Sup<strong>pl</strong>y Ø/V/Hz<br />

Cooling Capacity kW<br />

Heating Capacity kW<br />

Current Nominal running current A<br />

Fan Motor Type<br />

Fan Type<br />

Motor Output x Number <strong>of</strong> Unit<br />

Air Flow Rate(H/M/L) cmm<br />

External Static Pressure mmAq<br />

Capacitor<br />

Drive<br />

μF/Vac<br />

Coil Row x Columns x FPI mm<br />

Dimensions(WxHxD) Body mm<br />

Weight<br />

Air Filter<br />

Body kg<br />

Sound Level (H/M/L) dB(A)+3<br />

Piping Liquid mm<br />

Connections Gas mm<br />

Drain(OD/ID) mm<br />

Dehumidification Rate<br />

Safety devices<br />

Temperature Sensor<br />

Referigerant<br />

Referigerant Control<br />

Connectable outdoor unit<br />

l/h<br />

Power and transmission interunit cable No.x mm2 Note :<br />

1. Capacities are based on the following conditions:<br />

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />

- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />

- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />

Piping Length - Interconnecting Piping Length 7.5m<br />

- Level Difference <strong>of</strong> Zero.<br />

2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />

3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />

1/220-240 / 50<br />

Refer to each combination table<br />

3.65<br />

Induction<br />

Sirocco Fan<br />

357*2<br />

50/45/40<br />

15<br />

15/450<br />

Direct Drive<br />

4Rx13Cx19<br />

1,230*380*590<br />

62<br />

Long life filter<br />

46/44/42<br />

9.52<br />

15.88<br />

32/25<br />

6.5<br />

Fuse, Thermal protector for fan motor<br />

Thermistor<br />

R410A<br />

EEV(Outdoor Unit)<br />

Single A<br />

4*0.75(Including Earth)<br />

Conversion Formula<br />

kcal/h = kW × 859.8<br />

CFM = CMM × 35.3<br />

110 Duct (H)