Refrigerant piping work 5CSL0-06B<br />

How to close the stop valve<br />

1. Insert a hexagon wrench into the valve stem, and turn the<br />

valve stem clockwise.<br />

2. When the valve stem cannot be turned any more, stop<br />

turning. Now, the valve is closed.<br />

Service port<br />

Valve stem<br />

Valve cap<br />

Field piping<br />

connection part<br />

Silicon sealant<br />

(Take care not to generate cavity.)<br />

Opening direction Opening direction<br />

<br />

Cautions on handling the valve cap<br />

• The valve is sealed in the arrow area. Take care not to<br />

damage the arrow area.<br />

Valve cap<br />

SVC valve<br />

(valve cap attachment area)<br />

• After handling the valve, make sure to tighten the valve<br />

cap securely.<br />

Liquid line Gas line<br />

3.4~4.2 m-kgf 6.3~8.2 m-kgf<br />

Cautions on handling the service port<br />

• Use charge hose equipped with push in the work.<br />

• After the work, make sure to tighten the valve cap securely.<br />

Tightening torque.....8.5~10.3 ft·lbf<br />

Do not ap<strong>pl</strong>y any force to the valve cap<br />

Using a spanner on the valve cap and the valve body could<br />

cause a refrigerant leak.<br />

Oil Trap<br />

• Necessity <strong>of</strong> trap<br />

Since there is fear <strong>of</strong> the oil held inside the riser piping<br />

flowing back into the compressor when stopped and causing<br />

liquid compression phenomenon, or cases <strong>of</strong> deterioration<br />

<strong>of</strong> oil return, it will be necessary to provide a trap at an<br />

appropriate <strong>pl</strong>ace in the riser gas piping.<br />

• Trap installation spacing<br />

NOTE<br />

Spanner<br />

prohibition to<br />

valve cap and<br />

body part<br />

SVC valve <strong>of</strong> two<br />

hands method<br />

SVC valve <strong>of</strong> one<br />

hands method<br />

294 Guideline for each installation process<br />

Spanner<br />

Torque<br />

wrench<br />

Torque<br />

wrench<br />

A trap is not necessary when the outdoor unit is installed<br />

in a higher position than the indoor unit.