Specifications 5CSL0-06B<br />

1.2.2 Specifications<br />

Power Sup<strong>pl</strong>y Ø/V/Hz<br />

Cooling Capacity kW<br />

Heating Capacity kW<br />

Current Nominal running current A<br />

Fan Motor Type<br />

Fan Type<br />

Motor Output x Number <strong>of</strong> Unit<br />

Air Flow Rate(H/M/L) cmm<br />

Capacitor μF/Vac<br />

Drive<br />

Coil Row x Column x FPI mm<br />

Dimensions (WxHxD) Body mm<br />

Weight Body kg<br />

Air Filter<br />

Sound Level (H/M/L) dB(A)+3<br />

Piping Liquid mm<br />

Connections Gas mm<br />

Drain(OD/ID) mm<br />

Dehumidification Rate l/h<br />

Safety devices<br />

Temperature Sensor<br />

Referigerant<br />

Referigerant Control<br />

Indoor unit type Ceilling & Floor<br />

Model<br />

Connectable outdoor unit<br />

Power and transmission interunit cable No.x mm2 AVNH09GELAD<br />

[UV09 NED]<br />

Note :<br />

1. Capacities are based on the following conditions:<br />

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB<br />

- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB<br />

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB<br />

- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB<br />

Piping Length - Interconnecting Piping Length 7.5m<br />

- Level Difference <strong>of</strong> Zero.<br />

2. Cooling/heating capacity <strong>of</strong> indoor unit can be lower when it is connected to variable outdoor.<br />

3. Wiring cable size must com<strong>pl</strong>y with the ap<strong>pl</strong>icable local and national code.<br />

AVNH12GELAD<br />

[UV12 NED]<br />

UVNH186BLAD<br />

[UV18 NBD]<br />

1 / 220-240 / 50 1 / 220-240 / 50 1 / 220-240 / 50<br />

Refer to each combination table<br />

BLDC BLDC Induction<br />

Cross Flow Fan Cross Flow Fan Cross Flow Fan<br />

20.0*1 20.0*1 30.0*1<br />

7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.2 13.5 / 12 / 11<br />

- - 1.5/370<br />

Direct Drive Direct Drive Direct Drive<br />

2R x 12C x 20 2R x 12C x 20 2R x 12C x 18<br />

900*200*490 900*200*490 1,200*205*615<br />

13.7 13.7 30.0<br />

Long life filter Long life filter Long life filter<br />

40 / 36 / 31 40 / 36 / 31 43 / 40 / 37<br />

6.35 6.35 6.35<br />

9.52 9.52 12.7<br />

20/16 20/16 20/16<br />

0.93 1.3 1.54<br />

Thermistor<br />

Fuse, Thermal protector for fan motor<br />

Thermistor Thermistor<br />

R410A R410A R410A<br />

EEV(Outdoor Unit) EEV(Outdoor Unit) EEV(Outdoor Unit)<br />

Single A Single A Single A<br />

4*0.75(Including Earth) 4*0.75(Including Earth) 4*0.75(Including Earth)<br />

Conversion Formula<br />

kcal/h = kW × 859.8<br />

CFM = CMM × 35.3<br />