TECHNICAL DATA<br />

ELECTRICAL:<br />

Solenoid-Pilot actuated V<strong>316</strong> valves are available with a variety of different solenoids for both nonhazardous<br />

and hazardous locations. Basic details of these actuators are listed below. Dimensions, product numbers, and<br />

other details may be found on pages 5.1 through 5.6. For additional data consult factory.<br />

NON HAZARDOUS LOCATION SOLENOIDS<br />

Suffi x<br />

Identifi cation<br />

Protection<br />

Classifi cation<br />

Area Classifi cation<br />

and (Gas Grouping)<br />

3.2<br />

Certifi cation-<br />

(Conformance)<br />

-U General Purpose Indoor & Outdoor CSA NEMA 1, 2, 3<br />

-HC -U General Purpose Indoor & Outdoor CSA NEMA 4;<br />

IP65 per IEC 529<br />

HAZARDOUS LOCATION SOLENOIDS<br />

Suffi x<br />

Identifi cation<br />

-XX<br />

Page 5.3<br />

-LB-XX<br />

Page 5.4<br />

-XN<br />

Page 5.3<br />

-LB-XN<br />

Page 5.4<br />

-XDAS<br />

or<br />

-XDAT<br />

Page 5.3<br />

-XMAA<br />

or<br />

-XMAE<br />

or<br />

-XMAF<br />

or<br />

-XMAG<br />

Page 5.5<br />

-XMFA<br />

or<br />

-XMFE<br />

or<br />

-XMFF<br />

or<br />

-XMFG<br />

Page 5.5<br />

-HC-XISC<br />

-HCC-XISC<br />

Page 5.6<br />

-HC-XISX6<br />

-HCC-XISX6<br />

Page 5.6<br />

-XIFA<br />

or<br />

-XIFE<br />

or<br />

-XIFF<br />

Page 5.6<br />

Protection<br />

Classifi cation<br />

Area Classifi cation<br />

and (Gas Grouping)<br />

Hazardous Locations Class I, Division 2 (A & B)<br />

Class I, Division 1 (C & D)<br />

Class II, Division 1 (E, F, & G)<br />

Hazardous Locations Class I, Division 2 (A & B)<br />

Class I, Division 1 (C & D)<br />

Class II, Division 1 (E, F, & G)<br />

(d) Flameproof Zones 1 and 2<br />

(IIB+H2) Category 2G<br />

T4<br />

(d) Flameproof Zones 1 and 2<br />

(IIB+H2) Category 2G<br />

T6<br />

(d) Flameproof Zones 1 and 2<br />

(IIC) Category 2G<br />

(m) Encapsulation<br />

(e) Increased Safety<br />

(m) Encapsulation<br />

(e) Increased Safety<br />

Zones 1 and 2<br />

(II) Category 2G<br />

Zones 1 and 2<br />

(II) Category 2G<br />

Hazardous Locations Class I,<br />

Groups (A, B, C & D)<br />

Class II, Groups (E, F & G)<br />

Class III, Division 1<br />

(ia) Intrinsic Safe Zones 0, 1 and 2<br />

(IIC) Category 1G<br />

T6<br />

(ib) Intrinsic Safe Zones 1 and 2<br />

(IIB) Category 1G<br />

UL<br />

CSA<br />

UL<br />

CSA<br />

Certifi cation-<br />

(Conformance)<br />

ATEX IP66<br />

ATEX IP66<br />

NEMA 7 & 9<br />

NEMA 7 & 9<br />

ATEX IP66 and IP67<br />

ATEX IP66 and IP67<br />

ATEX IP66 and IP67<br />

Factory Mutual<br />

CSA<br />

NEMA 4<br />

ATEX IP65<br />

ATEX IP66 and IP67<br />

Ingress<br />

Protection<br />

Ingress<br />

Protection