TECHNICAL DATA<br />
ELECTRICAL:<br />
Solenoid-Pilot actuated V<strong>316</strong> valves are available with a variety of different solenoids for both nonhazardous<br />
and hazardous locations. Basic details of these actuators are listed below. Dimensions, product numbers, and<br />
other details may be found on pages 5.1 through 5.6. For additional data consult factory.<br />
NON HAZARDOUS LOCATION SOLENOIDS<br />
Suffi x<br />
Identifi cation<br />
Protection<br />
Classifi cation<br />
Area Classifi cation<br />
and (Gas Grouping)<br />
3.2<br />
Certifi cation-<br />
(Conformance)<br />
-U General Purpose Indoor & Outdoor CSA NEMA 1, 2, 3<br />
-HC -U General Purpose Indoor & Outdoor CSA NEMA 4;<br />
IP65 per IEC 529<br />
HAZARDOUS LOCATION SOLENOIDS<br />
Suffi x<br />
Identifi cation<br />
-XX<br />
Page 5.3<br />
-LB-XX<br />
Page 5.4<br />
-XN<br />
Page 5.3<br />
-LB-XN<br />
Page 5.4<br />
-XDAS<br />
or<br />
-XDAT<br />
Page 5.3<br />
-XMAA<br />
or<br />
-XMAE<br />
or<br />
-XMAF<br />
or<br />
-XMAG<br />
Page 5.5<br />
-XMFA<br />
or<br />
-XMFE<br />
or<br />
-XMFF<br />
or<br />
-XMFG<br />
Page 5.5<br />
-HC-XISC<br />
-HCC-XISC<br />
Page 5.6<br />
-HC-XISX6<br />
-HCC-XISX6<br />
Page 5.6<br />
-XIFA<br />
or<br />
-XIFE<br />
or<br />
-XIFF<br />
Page 5.6<br />
Protection<br />
Classifi cation<br />
Area Classifi cation<br />
and (Gas Grouping)<br />
Hazardous Locations Class I, Division 2 (A & B)<br />
Class I, Division 1 (C & D)<br />
Class II, Division 1 (E, F, & G)<br />
Hazardous Locations Class I, Division 2 (A & B)<br />
Class I, Division 1 (C & D)<br />
Class II, Division 1 (E, F, & G)<br />
(d) Flameproof Zones 1 and 2<br />
(IIB+H2) Category 2G<br />
T4<br />
(d) Flameproof Zones 1 and 2<br />
(IIB+H2) Category 2G<br />
T6<br />
(d) Flameproof Zones 1 and 2<br />
(IIC) Category 2G<br />
(m) Encapsulation<br />
(e) Increased Safety<br />
(m) Encapsulation<br />
(e) Increased Safety<br />
Zones 1 and 2<br />
(II) Category 2G<br />
Zones 1 and 2<br />
(II) Category 2G<br />
Hazardous Locations Class I,<br />
Groups (A, B, C & D)<br />
Class II, Groups (E, F & G)<br />
Class III, Division 1<br />
(ia) Intrinsic Safe Zones 0, 1 and 2<br />
(IIC) Category 1G<br />
T6<br />
(ib) Intrinsic Safe Zones 1 and 2<br />
(IIB) Category 1G<br />
UL<br />
CSA<br />
UL<br />
CSA<br />
Certifi cation-<br />
(Conformance)<br />
ATEX IP66<br />
ATEX IP66<br />
NEMA 7 & 9<br />
NEMA 7 & 9<br />
ATEX IP66 and IP67<br />
ATEX IP66 and IP67<br />
ATEX IP66 and IP67<br />
Factory Mutual<br />
CSA<br />
NEMA 4<br />
ATEX IP65<br />
ATEX IP66 and IP67<br />
Ingress<br />
Protection<br />
Ingress<br />
Protection