Operation manual - Werner Dosiertechnik
Operation manual - Werner Dosiertechnik
Operation manual - Werner Dosiertechnik
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WDT Operating Instructions PAKDOS 60 (V61-04/06) page 14 von 22<br />
6.2 LED Indicators for function and irritations<br />
Grüne LED L0:<br />
Green LED – indicates program switch and external inputs<br />
on contiuously: GRANUDOS in operation<br />
no light: Transformer Tr. 2 or fuse F1 for control system burnt<br />
fast blink (0,5 second on, 0,5 second off...)<br />
- programme knob not on a programme position<br />
- end of test programme<br />
- dosing switched off with front fascia switch<br />
slow blink (2 seconds on, 2 seconds off)<br />
External switch off e.g. by a central control on conn. S04-5<br />
Flickering:<br />
- dosing switched off on program BZ<br />
- external switch off of dosing on connector S04-4<br />
-<br />
Red LED shows function of dosing and interruptions indicated by the different<br />
Sensors. At any interruption dosing stops. Flickering of L4 shows that the dosing motor is<br />
activated, the motor should run.<br />
LED irritation what<br />
happens<br />
see below<br />
L1 burns water level high 2<br />
water flow too low<br />
L2 burns water level low 1<br />
pump pressure low 1<br />
L3 burns counter pressure high (external) 1<br />
L4 burns dosing hopper empty 3<br />
blink slow fuse F2 315 mAT – dosing motor 2<br />
L1 + L4 L1 blink slow fuse F3 800 mAT or power transformer faulty 1<br />
L4 blink fast<br />
Effect 1: dosing stops, booster pump stops<br />
Effect 2: dosing stops<br />
Effect 3: only indication, no further