WDT Operating Instructions PAKDOS 60 (V61-04/06) page 14 von 22<br />

6.2 LED Indicators for function and irritations<br />

Grüne LED L0:<br />

Green LED – indicates program switch and external inputs<br />

on contiuously: GRANUDOS in operation<br />

no light: Transformer Tr. 2 or fuse F1 for control system burnt<br />

fast blink (0,5 second on, 0,5 second off...)<br />

- programme knob not on a programme position<br />

- end of test programme<br />

- dosing switched off with front fascia switch<br />

slow blink (2 seconds on, 2 seconds off)<br />

External switch off e.g. by a central control on conn. S04-5<br />

Flickering:<br />

- dosing switched off on program BZ<br />

- external switch off of dosing on connector S04-4<br />

-<br />

Red LED shows function of dosing and interruptions indicated by the different<br />

Sensors. At any interruption dosing stops. Flickering of L4 shows that the dosing motor is<br />

activated, the motor should run.<br />

LED irritation what<br />

happens<br />

see below<br />

L1 burns water level high 2<br />

water flow too low<br />

L2 burns water level low 1<br />

pump pressure low 1<br />

L3 burns counter pressure high (external) 1<br />

L4 burns dosing hopper empty 3<br />

blink slow fuse F2 315 mAT – dosing motor 2<br />

L1 + L4 L1 blink slow fuse F3 800 mAT or power transformer faulty 1<br />

L4 blink fast<br />

Effect 1: dosing stops, booster pump stops<br />

Effect 2: dosing stops<br />

Effect 3: only indication, no further