WDT Operating Instructions PAKDOS 60 (V61-04/06) page 16 von 22<br />

3. Empty switch is faulty – fit a new one<br />

L4 blink slow fuse F2 of the dosing motor 315 mAT burnt<br />

1. dosing motor may be blocked by<br />

- particles in the powder<br />

- blocking of the powder in the dosing screw<br />

- blocking of the dosing tube maybe by<br />

humidity<br />

In every case dismount the dosing motor with the screwThe screw<br />

must have a very smooth surface. Clean dosing tube proper.<br />

2. dosing motor faulty<br />

L4 blinks fast Option: if opical sensor is fitted to monitor the powder dosing:<br />

For longer than 8 minutes no powder has been seen by the sensor.<br />

1. reasons for that as above indicated<br />

adjustment of the with clear water and clean transparent tube the switch LED must<br />

opto sensor burn. Turn adjusting screw to left till end (LED off) then again to right<br />

(Carlo Gavazzi) till the LED burns + 10°<br />

.