- Page 1 and 2:
GESTRA Technical Information Steam
- Page 3 and 4:
GESTRA Steam Traps and Steam Trap M
- Page 5 and 6:
For steam and energy management, we
- Page 7 and 8:
Thermostatic Steam Traps BK with Du
- Page 9 and 10:
Thermostatic Steam Traps MK with Me
- Page 11 and 12:
Ball-Float Traps UNA PN 1 - PN 1 0
- Page 13 and 14:
Ball-Float Traps UNA PN 1 - PN Capa
- Page 15 and 16:
Thermodynamic Steam Traps DK PN 0,
- Page 17 and 18:
Steam Traps for Special Application
- Page 19 and 20:
Steam Traps for Special Application
- Page 21 and 22:
Steam Trap Units ECONOline for UNIV
- Page 23 and 24:
Testing Steam Traps Like any other
- Page 25 and 26:
Steam Trap Monitoring Equipment Sys
- Page 27:
Condensate Collector and Steam Mani
- Page 30 and 31:
GESTRA DISCO Non-Return Valves 30 G
- Page 32 and 33:
DISCO ® Non-Return Valves RK, PN 6
- Page 34 and 35:
DISCO ® Non-Return Valves RK, PN 6
- Page 36 and 37:
DISCO ® Non-Return Valves RK, PN 6
- Page 38 and 39:
DISCO ® Non-Return Valves RK, PN 4
- Page 40 and 41:
DISCO ® Non-Return Valves RK, PN 6
- Page 42 and 43:
DISCO ® Non-Return Valves RK, PN 6
- Page 44 and 45:
DISCOCHECK ® Dual-Plate Check Valv
- Page 46 and 47:
DISCOCHECK ® Dual-Plate Check Valv
- Page 48 and 49:
DISCO ® Swing Check Valves CB DN 5
- Page 50 and 51:
Swing Check Valves WB without sprin
- Page 52 and 53:
NAF-Check Valves DN 40 - 1000 mm, P
- Page 54 and 55:
GESTRA Control Valves ZK 54 GESTRA
- Page 56 and 57: Cooling Water Control Valves CW GES
- Page 58 and 59: Return-Temperature Control Valves B
- Page 60 and 61: Return-Temperature Control Valves B
- Page 62 and 63: Self-Acting Pressure Control Pressu
- Page 64 and 65: Self-Acting Temperature Controllers
- Page 66 and 67: Control Valves with Electric and Pn
- Page 68 and 69: Control Valves ZK with Radial Stage
- Page 70 and 71: Control Valves ZK with Radial Stage
- Page 72 and 73: Strainers GSF H H 1 H H 1 72 B S
- Page 74 and 75: Stop Valves GAV H 1 74 L1 Stop Valv
- Page 76 and 77: SPECTOR Product Range GESTRA’s SP
- Page 78 and 79: How to Read Type Codes GESTRA Type
- Page 80 and 81: GESTRA Steam Plant D 80 T P S A J B
- Page 82 and 83: Fundamental Principles of Measureme
- Page 84 and 85: Type Approvals at a Glance GESTRA B
- Page 86 and 87: Type Approval Nos. at a Glance Type
- Page 88 and 89: Level Limitation Low-Level Limiter
- Page 90 and 91: Description 1. Conductivity Measure
- Page 92 and 93: SPECTORcompact Where formerly two d
- Page 94 and 95: Self-Monitoring Low/High-Level Alar
- Page 96 and 97: Modulating Level Control - Conventi
- Page 98 and 99: Accessories for Liquid-Level Alarms
- Page 100 and 101: Level Probes and Control Units for
- Page 102 and 103: Marine Applications Level Electrode
- Page 104 and 105: GESTRA Equipment for Energy Supply
- Page 108 and 109: Temperature Control Conventional Tr
- Page 110 and 111: Conductivity Monitoring Basic Princ
- Page 112 and 113: Conductivity Spector Bus/Compact Lr
- Page 114 and 115: Conductivity Monitoring with Manual
- Page 116 and 117: Conductivity Monitoring with Manual
- Page 118 and 119: Ancillaries: Level Pots and Portabl
- Page 120 and 121: Continuous Blowdown Valves 120 L BA
- Page 122 and 123: Programme-Controlled Blowdown Syste
- Page 124 and 125: Rapid-Action Intermittent Blowdown
- Page 126 and 127: Contamination Detectors for Condens
- Page 128 and 129: Ingress of Oil in Cooling Water Sys
- Page 130 and 131: Flowmeters for Steam, Gases and Liq
- Page 132 and 133: GESTRA SPECTOR Family SpECTorcom/co
- Page 134 and 135: Condensate Recovery and Return Syst
- Page 136 and 137: Closed-Type Condensate Recovery and
- Page 138 and 139: Steam Powered Condensate Return Tan
- Page 140 and 141: Steam Regenerators Steam regenerato
- Page 142 and 143: Flash Vessels Type VD Flash Vessels
- Page 144 and 145: Condensate Dampening Pot ED Technic
- Page 146 and 147: Controls Pump Controls Function The
- Page 148 and 149: Questionnaire for preparing offers
- Page 150 and 151: Questionnaire for preparing offers
- Page 152 and 153: Questionnaire for preparing offers
- Page 154 and 155: Questionnaire for preparing offers
- Page 156 and 157:
156 Our Mobile Testing Station For
- Page 158 and 159:
Technical Advice and Training Semin
- Page 160 and 161:
Useful Conversions MASS 1 kilogramm
- Page 162 and 163:
EC Pressure Equipment Directive (PE
- Page 164 and 165:
EC Pressure Equipment Directive (PE
- Page 166 and 167:
Combined Imperial and S. I. Steam T
- Page 168 and 169:
DIN Material Reference Chart 168 EN
- Page 170 and 171:
Technical Literature Technical Docu
- Page 172 and 173:
Index by Product Name Product Type
- Page 174 and 175:
Index by Product Name Product Type
- Page 176 and 177:
Index by Product Code Type Product
- Page 178:
Note: Responable care has been take