90<br />

AHEAD OF THE FLOW ®<br />

Pipe Support Spacing<br />

ABS & PVC piping should be supported just as any other piping<br />

system. Ordinary hanger straps may be used for suspending<br />

below floor systems. The light weight of ABS & PVC may lead<br />

one to believe that wider hanger spacing could be permitted.<br />

Four or five foot spacing is recommended, with proper support<br />

at the base of each stack. CPVC Pressure pipe should be supported<br />

every three feet.<br />

Since ABS, CPVC, & PVC are non-metallic, they are not as<br />

“stiff” as their metal counterparts, therefore the installer must<br />

exercise care to assure proper alignment of required grades.<br />

Branch fittings serving trap arms should also be secured to the<br />

framing to prevent movement. Hanger straps should not be so<br />

tight as to compress, distort, cut, or abrade the piping.<br />

ALLOWING FOR EXPANSION-In Pressure piping, allowance<br />

for expansion due to changing temperature is important. It is<br />

good practice to include a 12-inch offset every ten feet in a<br />

straight run. Illustrated below are several methods for providing<br />

off sets.<br />

Specific Gravity Correction Factor<br />

1.1 0.98<br />

1.2 0.96<br />

1.4 0.93<br />

1.6 0.90<br />

2.0 0.85<br />

2.5 0.80<br />

The above data is for un-insulated lines. For insulated lines<br />

reduce spans to 70% of table values. For spans of less than 2<br />

feet continuous support should be used.<br />

Pipe Support Spacing, ABS-DWV, Ft.<br />

Nominal<br />

Size 70°F 100°F 140°F<br />

11/4 41/2 41/2 4<br />

11/2 5 5 41/2 2 5 5 41/2 3 6 6 51/2 4 61/4 61/4 53/4 6 63/4 63/4 6<br />

8 7 7 61/2 10 7 7 61/2 12 7 7 61/2 NIBCO INC. WORLD HEADQUARTERS 1516 MIDDLEBURY ST. ELKHART, IN 46516-4740 USA PH: 1.800.234.0227<br />

TECH SERVICES PH: 1.888.446.4226 FAX: 1.888.336.4226 INTERNATIONAL OFFICE PH: +1.574.295.3327 FAX: +1.574.295.3455<br />

www.nibco.com<br />

www.nibco.com<br />

Revised 9/10/2009<br />

Pipe Support Spacing, CPVC-CTS, Ft.<br />

Nominal<br />

Size 70°F 100°F 140°F 180°F<br />

1/2 3 3 21/2 21/2 3/4 3 3 21/2 21/2 1 3 3 21/2 21/2 11/4 4 4 31/2 31/2 11/2 4 4 31/2 31/2 2 4 4 31/2 31/2 Pipe Support Spacing, PVC-Schedule 40, Ft.<br />

Nominal<br />

Size 70°F 100°F 140°F<br />

1/2 4 1/2 4 2 1/2<br />

3/4 5 4 2 1/2<br />

1 5 1/2 4 1/2 2 1/2<br />

1 1/4 6 5 3<br />

1 1/2 6 5 3<br />

2 6 5 3<br />

2 1/2 7 6 3 1/2<br />

3 7 6 3 1/2<br />

4 7 1/2 6 1/2 4<br />

5 7 1/2 6 1/2 4<br />

6 8 1/2 7 1/2 4 1/2<br />

8 9 8 4 1/2<br />

10 10 8 1/2 5<br />

12 10 8 1/2 5<br />

Pipe Support Spacing, PVC-Schedule 80, Ft.<br />

Nominal<br />

Size 70°F 100°F 140°F<br />

1/2 5 4 1/2 2 1/2<br />

3/4 5 1/2 4 2 1/2<br />

1 6 5 3<br />

1 1/4 6 1/2 5 1/2 3 1/2<br />

1 1/2 6 1/2 5 1/2 3 1/2<br />

2 7 6 3 1/2<br />

2 1/2 8 7 4<br />

3 8 7 4<br />

4 9 7 1/2 4 1/2<br />

6 10 9 5<br />

8 11 9 1/2 5 1/2