Turbomachinery technology for gas expansion - Air Products and ...
Turbomachinery technology for gas expansion - Air Products and ...
Turbomachinery technology for gas expansion - Air Products and ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Products</strong> to meet your applications<br />
St<strong>and</strong>ard <strong>and</strong><br />
custom machinery<br />
Our focus is providing the right<br />
solution <strong>for</strong> your application. We<br />
offer both st<strong>and</strong>ard <strong>and</strong> customengineered<br />
cryogenic <strong>and</strong> warm <strong>gas</strong><br />
centrifugal turbomachinery used <strong>for</strong><br />
refrigeration <strong>and</strong> power recovery in<br />
diverse market segments. Depending<br />
on your needs, we can customize<br />
our equipment to meet your requirements<br />
<strong>and</strong> applicable regulations.<br />
Since we are both a manufacturer<br />
<strong>and</strong> an operator, we underst<strong>and</strong> your<br />
applications <strong>and</strong> can provide a total<br />
solution—no matter how small or<br />
complex your needs may be.<br />
This represents an overview of <strong>Air</strong> <strong>Products</strong>’<br />
turbomachinery capabilities. If your needs fall<br />
outside of these application ranges, please call<br />
<strong>for</strong> additional in<strong>for</strong>mation.<br />
4<br />
Market segments<br />
<strong>Air</strong> Separation Natural Gas Other<br />
• Gas plants • NGL processing plants • Helium<br />
• Liquefiers • LNG peak shavers • Waste heat power generation<br />
• Specialty cycles • Base load LNG • Hydrogen <strong>and</strong> CO<br />
<strong>and</strong> applications<br />
Typical design capabilities<br />
• Ethylene • Specialty applications<br />
Power 2 kW to 12 MW<br />
(5 to 16,000 hp)<br />
Speed Up to 100,000 rpm<br />
Inlet pressure 1.5 to 98.5 kg/cm 2 g<br />
(25 to 1,400 psig)<br />
Temperature –268˚C to +260˚C<br />
(–450˚F to +500˚F)<br />
Outlet flow 56 to 15,300 am 3 /hr<br />
(33 to 9,000 ACFM)<br />
Impellers 50–550 mm<br />
(2 to 22 inch)<br />
Product operating range<br />
Outlet flow (am 3 /hr)<br />
20,000<br />
2,000<br />
200<br />
Dissipative<br />
Geared<br />
20<br />
1 30 600<br />
12,000<br />
Power (KW)<br />
Comp<strong>and</strong>er