TRITON Error Codes - Cypress Advantage
TRITON Error Codes - Cypress Advantage
TRITON Error Codes - Cypress Advantage
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Description: SPED keypad is not replying to main board<br />
Recommended Action:<br />
Status valid only for units with SPED keypad device installed.<br />
1. Make sure the battery is seated secure in the battery holder.<br />
2. Make sure the tamper screw is secure to the SPED Module. Reset the Cash Dispenser by turning<br />
OFF the AC power switch for a few seconds and switching it back ON. Clear the error.<br />
3. If the error persists, replace the SPED keypad module.<br />
<strong>Error</strong> Code: 205<br />
Description: SPED keypad reported tamper condition<br />
Recommended Action:<br />
Status valid only for units with SPED keypad device installed. Make sure the battery is seated secure in<br />
the battery holder. Make sure the tamper screw is secure to the SPED module. Reset the cash dispenser<br />
and clear the error. If the error persists, replace the SPED keypad module.<br />
<strong>Error</strong> Code: 206<br />
Description: SPED keypad could not perform a successful command within SPED_MAX_ATTEMPTS<br />
tries<br />
Recommended Action:<br />
Status valid only for units with SPED keypad device installed. Reset the cash dispenser and clear the<br />
error. If error persists, replace the SPED keypad module.<br />
<strong>Error</strong> Code: 207<br />
Description: SPED not detected<br />
Recommended Action:<br />
This <strong>Error</strong>/Status Code is valid for units with SPED keypad device installed.<br />
1. Check the cable and connections from J7A on the docking station to the SPED board.<br />
2. Verify that the SPED board has the correct DC voltages applied to it.<br />
3. If the DC voltages applied to the SPED board correct and the cables are in good condition and<br />
seated properly, replace the SPED board.<br />
ERROR CODE: 210<br />
DESCRIPTION: Dispenser type unknown<br />
RECOMMENDED ACTION:<br />
Inspect the power and communication cables between the docking board and the dispensing mechanism.<br />
Make sure they are not damaged and that the connectors are securely attached at both ends of the<br />
cable. Clear the error. Reset the cash dispenser by pushing the AC power switch to the OFF position<br />
for about 30 seconds then pushing it to the back to the ON position. If the error persists reload software<br />
on the main board assembly. If the error continues to persist, replace the dispensing mechanism.<br />
22