Description: SPED keypad is not replying to main board<br />

Recommended Action:<br />

Status valid only for units with SPED keypad device installed.<br />

1. Make sure the battery is seated secure in the battery holder.<br />

2. Make sure the tamper screw is secure to the SPED Module. Reset the Cash Dispenser by turning<br />

OFF the AC power switch for a few seconds and switching it back ON. Clear the error.<br />

3. If the error persists, replace the SPED keypad module.<br />

<strong>Error</strong> Code: 205<br />

Description: SPED keypad reported tamper condition<br />

Recommended Action:<br />

Status valid only for units with SPED keypad device installed. Make sure the battery is seated secure in<br />

the battery holder. Make sure the tamper screw is secure to the SPED module. Reset the cash dispenser<br />

and clear the error. If the error persists, replace the SPED keypad module.<br />

<strong>Error</strong> Code: 206<br />

Description: SPED keypad could not perform a successful command within SPED_MAX_ATTEMPTS<br />

tries<br />

Recommended Action:<br />

Status valid only for units with SPED keypad device installed. Reset the cash dispenser and clear the<br />

error. If error persists, replace the SPED keypad module.<br />

<strong>Error</strong> Code: 207<br />

Description: SPED not detected<br />

Recommended Action:<br />

This <strong>Error</strong>/Status Code is valid for units with SPED keypad device installed.<br />

1. Check the cable and connections from J7A on the docking station to the SPED board.<br />

2. Verify that the SPED board has the correct DC voltages applied to it.<br />

3. If the DC voltages applied to the SPED board correct and the cables are in good condition and<br />

seated properly, replace the SPED board.<br />

ERROR CODE: 210<br />

DESCRIPTION: Dispenser type unknown<br />

RECOMMENDED ACTION:<br />

Inspect the power and communication cables between the docking board and the dispensing mechanism.<br />

Make sure they are not damaged and that the connectors are securely attached at both ends of the<br />

cable. Clear the error. Reset the cash dispenser by pushing the AC power switch to the OFF position<br />

for about 30 seconds then pushing it to the back to the ON position. If the error persists reload software<br />

on the main board assembly. If the error continues to persist, replace the dispensing mechanism.<br />