TRITON Error Codes - Cypress Advantage
TRITON Error Codes - Cypress Advantage
TRITON Error Codes - Cypress Advantage
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
ERROR CODE: 395<br />
DESCRIPTION: Multiple cassette of the same type.<br />
RECOMMENDED ACTION:<br />
NMD dispenser allows for only one of each cassette ID to be installed. Verify each cassette ID. Replace<br />
cassette or Inject New Cassette ID.<br />
ERROR CODE: 500<br />
DESCRIPTION: SPED Read <strong>Error</strong>.<br />
RECOMMENDED ACTION:<br />
Verify all SPED connections. Restart the operating system. Clear any errors conditions. Inspect the<br />
battery for a voltage reading of greater than 2.8 VDC. Replace SPED battery is below 2.8 VDC.<br />
Replace SPED module if error persists.<br />
ERROR CODE: 501<br />
DESCRIPTION: SPED invalid return record.<br />
RECOMMENDED ACTION: Refer to error 500.<br />
ERROR CODE: 502<br />
DESCRIPTION: SPED read type error.<br />
RECOMMENDED ACTION:<br />
Refer to error 500.<br />
ERROR CODE: 503<br />
DESCRIPTION: SPED invalid command.<br />
RECOMMENDED ACTION:<br />
Refer to error 500.<br />
ERROR CODE: 504<br />
DESCRIPTION: SPED invalid return ID.<br />
RECOMMENDED ACTION:<br />
Refer to error 500.<br />
ERROR CODE: 505<br />
DESCRIPTION: SPED device busy.<br />
RECOMMENDED ACTION:<br />
Refer to error 500.<br />
ERROR CODE: 506<br />
DESCRIPTION: SPED invalid request.<br />
RECOMMENDED ACTION:Refer to error 500.<br />
36