Product Description and Overview of Types<br />

2 General information<br />

2.4.12 Cooling<br />

If the thermal rating of the gear unit is not sufficient without additional cooling measures,<br />

the following may used:<br />

• Fan (independent of direction of rotation) on the drive shaft for 2- and 3- stage gear<br />

units. (See chapter 5.5.1). For gear units with fans on the input shaft, make sure that<br />

there is enough space in the axial and radial directions to allow for a sufficient supply<br />

of cooling air.<br />

• Integrated water cooling cover up to size 210, integrated water cooling cartridge for<br />

3- and 4- stage gear units. The water cooling cover may be combined with any lubrication<br />

types (see chapter 5.3.2 and 5.5.3).<br />

• A combination of a fan and a water cooling cover or cooling cartridge.<br />

• An oil supply system with an oil/water or oil/air heat exchanger.<br />

2.4.13 Motor connection<br />

SEW-EURODRIVE can supply the following variants with the gear unit:<br />

• Motor adapter with an elastic coupling for attaching IEC (B5) / NEMA ('C' face) motors<br />

(see chapter 6.4). The motor adapter may optionally be designed with a fan.<br />

• Steel construction as motor swing base and base plate (see chapter 6.5): Comprises<br />

gear unit + steel frame, as well as the necessary components such as input and<br />

output coupling, drum or disk brake, AC motor and protection guards.<br />

• Motor bracket with V-belt drive: Includes motor bracket, pulleys, V-belt and belt<br />

guard.<br />

• Motor scoop, including AC motor, coupling and protection guard.<br />

2.4.14 Backstop<br />

The gear units may optionally be equipped with or without coupling (see chapter 6.3)<br />

2.4.15 Condition monitoring<br />

A variety of optional equipment is available for condition monitoring:<br />

• PT100 temperature sensor (see chapter 7.1):<br />

For measuring the oil bath temperature<br />

• SEW DUO diagnostics system (see chapter 7.3):<br />

For monitoring the condition of the oil in the gear unit<br />

• SEW DUV diagnostics system (see chapter 7.4):<br />

For monitoring vibration of bearings and gears<br />

• Electrical oil level monitor on request<br />

12 <strong>Catalog</strong> – Helical and Bevel-Helical Gear Units X.. Series <strong>Horizontal</strong>