5 Cooling<br />

0 +50 +100<br />

-50<br />

°C<br />

Lubrication, Cooling and Heating<br />

5.5.2 Built-in cooling water cooling cover<br />

The water cooling cover is located on the gear unit’s assembly opening and is provided<br />

with cooling water through a water connection that is provided by the operator. It is available<br />

for sizes 180 to 210.<br />

The amount of heat that can be removed depends on the intake temperature and the<br />

volume flow of the cooling medium that flows through the unit. The permitted thermal<br />

rating is listed in the selection tables in chapter 10.2.<br />

STOP<br />

Contact SEW-EURODRIVE if chemically aggressive cooling media, such as brackish<br />

or salt water, are used.<br />

NOTE<br />

For the connection dimensions, refer to chapter 10.3.<br />

Structure The water cooling cover [1] is made of a corrosion-resistant aluminum alloy.<br />

Two bores G1/2' with pipe threads are available to connect to the cooling circuit. The<br />

piping is not included in the scope of delivery.<br />

Gear units in the water cooling cover version are delivered completely assembled.<br />

A water cooling cover may be retrofitted; consult SEW-EURODRIVE.<br />

[1]<br />

[2]<br />

[3]<br />

[2] [1] [3]<br />

Water cooling cover<br />

Inflow<br />

Return<br />

68 <strong>Catalog</strong> – Helical and Bevel-Helical Gear Units X.. Series <strong>Horizontal</strong><br />

[1]<br />

60982AXX