Project Planning<br />

4 Project planning procedure<br />

Altitude factor f 1<br />

NOTE<br />

Altitude H [m above sea level]<br />

Up to 1000 1000 - 2000 2000 - 3000 3000 - 4000 4000 - 5000<br />

f1 1.00 0.95 0.91 0.87 0.83<br />

Contact SEW-EURODRIVE in case of deviating conditions.<br />

4.2.9 Step 9: Checking the thermal rating:<br />

The gear unit’s thermal rating must be at least as large as the operating power on the<br />

input shaft [HSS]<br />

PT ≥ PK1 4.2.10 Step 10: Checking the external additional forces:<br />

Dependencies The permitted forces on the shaft depend on the following factors:<br />

• Service factor<br />

• Required bearing service life<br />

• Direction of the axial load (from or towards gear unit)<br />

• Application angle of the overhung load (rotating or at a specific position)<br />

• Application angle of the overhung load in relation to the shaft shoulder<br />

• Relation axial load/overhung load and vice versa<br />