Horizontal Electric Steam <strong>Boiler</strong>s
Sight Glass<br />
(Not Pictured)<br />
Description<br />
Applications<br />
Incoming Terminal Block<br />
Fuses<br />
Safety Valve<br />
(Not Pictured)<br />
Durable ASME Code horizontal electric<br />
steam boilers with flange-mounted,<br />
incoloy-sheathed heating elements. Each<br />
boiler is completely automatic with<br />
operating controls, water level control,<br />
and low water cut-off. All joints and seams<br />
are welded and hydrostatically tested.<br />
Constructed of heavy duty steel. <strong>Boiler</strong><br />
is fully insulated with 2” therma-fibre felt<br />
and covered with metal jacket for efficient<br />
operation. All boilers assembled in Cedar<br />
Rapids, IA USA.<br />
- Humidification of high tech environments<br />
such as computer rooms<br />
- Humidification of museum spaces<br />
- Sterilization in medical or laboratory<br />
environments<br />
- Manufacturing processes such as<br />
packaging and shrink labeling, plating,<br />
retreading<br />
- Health clubs and steam rooms<br />
- Food processing such as bakeries,<br />
breweries, shrimp cooking<br />
- Dry cleaning and tailoring<br />
Auxiliary Low<br />
Water Cut-Off<br />
(Behind Panel)<br />
Contactors<br />
Steam Outlet/<br />
Lifting Eye<br />
(Not Pictured)<br />
Pressure<br />
Gauge<br />
Blowdown<br />
Valve<br />
Standard Package Includes<br />
- Heating elements with magnetic<br />
contactors<br />
- McDonnell & Miller level control<br />
- Probe type aux. low water cut-off<br />
- Pressure control switch<br />
- Pressure limit switch with manual reset<br />
- Safety valve<br />
- Blowdown valve(s)<br />
- Feed water valve(s)<br />
Optional Features<br />
Pressure<br />
Switch(s)<br />
Float Control<br />
Blowdown<br />
- Control circuit transformer<br />
- Non-fused interlocking disconnect<br />
- Shunt trip<br />
- Ground fault protection<br />
- Progressive element sequencing<br />
- Low water level alarm<br />
- Building management system interface<br />
- Automatic bottom blowdown<br />
- Automatic surface blowdown<br />
- 24/7 timers<br />
- KWH meter<br />
- Ammeter<br />
- Steam room controls<br />
Primary Low<br />
Water Cut-Off<br />
& Pump<br />
Heating<br />
Element
480 Volt - Three Phase (115 Volt - 1Ph. Control Circut)<br />
KW<br />
9<br />
15<br />
18<br />
24<br />
30<br />
36<br />
48<br />
60<br />
74<br />
93<br />
112<br />
130<br />
148<br />
MODEL BOILER<br />
H.P.<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
BF<br />
9<br />
1.5<br />
1.8<br />
2.4<br />
3.0<br />
3.6<br />
4.8<br />
6.0<br />
7.4<br />
9.3<br />
13<br />
11.2<br />
14.8<br />
PRESSURE<br />
ASME<br />
CODE 4<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
125<br />
125<br />
125<br />
125<br />
125<br />
AMPHERE<br />
DRAW<br />
CONTRACTORS<br />
METHOD OF<br />
CONTROL<br />
TOTAL Quan. Amps. Std. Avail.<br />
10.83<br />
18.04<br />
21.65<br />
28.87<br />
36.08<br />
43.30<br />
57.74<br />
72.17<br />
89.01<br />
111.86<br />
134.72<br />
156.37<br />
178.02<br />
240 Volt - Three Phase (115 Volt - 1Ph. Control Circut)<br />
KW<br />
9<br />
15<br />
18<br />
24<br />
30<br />
36<br />
48<br />
60<br />
74<br />
93<br />
112<br />
130<br />
148<br />
MODEL BOILER<br />
H.P.<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
F<br />
9<br />
1.5<br />
1.8<br />
2.4<br />
3.0<br />
3.6<br />
4.8<br />
6.0<br />
7.4<br />
9.3<br />
13<br />
11.2<br />
14.8<br />
PRESSURE<br />
ASME<br />
CODE 4<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
125<br />
125<br />
125<br />
125<br />
125<br />
AMPHERE<br />
DRAW<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
3<br />
5<br />
6<br />
6<br />
6<br />
40<br />
40<br />
40<br />
40<br />
40<br />
50<br />
40<br />
40<br />
40<br />
40<br />
40<br />
40<br />
40<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2 3<br />
3<br />
3<br />
3<br />
3<br />
METHOD OF<br />
CONTROL<br />
TOTAL Quan. Amps. Std. Avail.<br />
21.65<br />
36.08<br />
43.30<br />
57.74<br />
72.17<br />
86.60<br />
115.47<br />
144.34<br />
178.02<br />
223.72<br />
269.43<br />
312.73<br />
356.03<br />
CONTRACTORS<br />
208 Volt - Three Phase (115 Volt - 1Ph. Control Circut)<br />
KW<br />
9<br />
15<br />
18<br />
24<br />
30<br />
36<br />
48<br />
60<br />
74<br />
93<br />
112<br />
130<br />
148<br />
MODEL BOILER<br />
H.P.<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
AF<br />
9<br />
1.5<br />
1.8<br />
2.4<br />
3.0<br />
3.6<br />
4.8<br />
6.0<br />
7.4<br />
9.3<br />
13<br />
11.2<br />
14.8<br />
PRESSURE<br />
ASME<br />
CODE 4<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
100<br />
125<br />
125<br />
125<br />
125<br />
125<br />
AMPHERE<br />
DRAW<br />
TOTAL<br />
24.98<br />
41.64<br />
49.96<br />
66.62<br />
83.27<br />
99.93<br />
133.23<br />
166.54<br />
205.40<br />
258.14<br />
310.88<br />
360.84<br />
410.81<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
3<br />
5<br />
6<br />
6<br />
6<br />
40<br />
40<br />
40<br />
40<br />
40<br />
50<br />
40<br />
40<br />
40<br />
40<br />
40<br />
40<br />
40<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2 3<br />
2<br />
3<br />
3<br />
3<br />
3<br />
3<br />
3<br />
3<br />
Quan. Amps. Std. Avail.<br />
1<br />
1<br />
1<br />
2<br />
3<br />
2<br />
4<br />
6<br />
3<br />
5<br />
6<br />
6<br />
6<br />
CONTRACTORS<br />
40<br />
50<br />
50<br />
40<br />
40<br />
50<br />
40<br />
40<br />
70<br />
60<br />
60<br />
70<br />
70<br />
METHOD OF<br />
CONTROL<br />
1<br />
1<br />
1<br />
1<br />
1<br />
1<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2<br />
2 3<br />
2<br />
3<br />
3<br />
3<br />
3<br />
3<br />
3<br />
3<br />
OPENINGS<br />
&<br />
DIMENSION<br />
BB<br />
BB<br />
BB<br />
CC<br />
CC<br />
DD<br />
EE<br />
EE<br />
FF<br />
GG<br />
GG<br />
GG<br />
GG<br />
OPENINGS<br />
&<br />
DIMENSION<br />
BB<br />
BB<br />
BB<br />
CC<br />
CC<br />
DD<br />
EE<br />
EE<br />
FF<br />
GG<br />
GG<br />
GG<br />
GG<br />
OPENINGS<br />
&<br />
DIMENSION<br />
BB<br />
BB<br />
BB<br />
CC<br />
CC<br />
DD<br />
EE<br />
EE<br />
FF<br />
GG<br />
GG<br />
GG<br />
GG<br />
APPROX.<br />
SHIP<br />
WT. LBS.<br />
425<br />
425<br />
425<br />
500<br />
500<br />
565<br />
675<br />
675<br />
850<br />
875<br />
875<br />
875<br />
875<br />
APPROX.<br />
SHIP<br />
WT. LBS.<br />
425<br />
425<br />
425<br />
500<br />
500<br />
565<br />
675<br />
675<br />
850<br />
875<br />
875<br />
875<br />
875<br />
APPROX.<br />
SHIP<br />
WT. LBS.<br />
425<br />
425<br />
425<br />
500<br />
500<br />
565<br />
675<br />
675<br />
850<br />
875<br />
875<br />
875<br />
875
Spec.<br />
BB<br />
CC<br />
DD<br />
EE<br />
FF<br />
GG<br />
Dimensions<br />
Length<br />
Overall<br />
A<br />
43:<br />
38"<br />
43"<br />
43"<br />
59"<br />
59"<br />
Width<br />
Overall<br />
B<br />
27"<br />
27"<br />
29"<br />
29"<br />
29"<br />
29"<br />
Footnotes:<br />
Add for<br />
Element<br />
Removal<br />
C<br />
Specifications subject to change without notice.<br />
0"<br />
0"<br />
0"<br />
18"<br />
0"<br />
40"<br />
D<br />
26"<br />
18"<br />
26"<br />
18"<br />
40"<br />
40"<br />
Height<br />
E<br />
29"<br />
29"<br />
29"<br />
32"<br />
32"<br />
32"<br />
Steam <strong>Boiler</strong> Openings<br />
Steam<br />
Outlet<br />
F<br />
3/4"<br />
1"<br />
1 1/4"<br />
1 1/4"<br />
1 1/4"<br />
2"<br />
Feed<br />
Water<br />
G<br />
3/4"<br />
3/4"<br />
3/4"<br />
3/4"<br />
3/4"<br />
3/4"<br />
Blow-Off<br />
Valve<br />
H<br />
3/4"<br />
3/4"<br />
3/4"<br />
3/4"<br />
1"<br />
1"<br />
Base<br />
Length<br />
J<br />
24 1/4"<br />
18 5/8"<br />
24 1/4"<br />
24 1/4"<br />
38 3/8"<br />
38 3/8"<br />
Base<br />
Width<br />
K<br />
20 1/2"<br />
20 1/2"<br />
20 1/2"<br />
20 1/2"<br />
20 1/2"<br />
20 1/2"<br />
1 One pressure switch provides on/off operation. Advise desired operation pressure.<br />
2 Two pressure switches used. Each switch controls approximately one half the load and are set at slightly<br />
different settings to allow two step operation. Advise desired operation pressure.<br />
3 Sequence control optional. (Add P to model number). Number of steps based on number of contactors.<br />
See price sheet for description of sequence control.<br />
4 Pressure shown is standard for steam boilers. High pressures is available on special orders.<br />
Sizes 60 KW and smaller are built under ASME "Miniature Code" which may exempt them from<br />
some local and state regulations. <strong>Boiler</strong>s can be furnished with low pressure controls and trim.<br />
Printed in USA<br />
<strong>Lattner</strong> <strong>Boiler</strong> Manufacturing Co.<br />
Steam Release<br />
Area<br />
Sq. Inches<br />
284<br />
264<br />
345<br />
345<br />
536<br />
536<br />
Water Capacity at<br />
Normal Level-Gallons<br />
9.3<br />
11.0<br />
14.0<br />
14.0<br />
23.0<br />
23.0<br />
<strong>Lattner</strong> <strong>Boiler</strong> Mfg. Co.<br />
1411 9th St. S.W. Box 1527<br />
Cedar Rapids, IA 52406<br />
800-345-1527 • 319-366-0778 • FAX 319-366-0770<br />
http://www.lattner.com • e-mail: info@lattner.com<br />
Bulletin No. SB-106-11