c) Disconnect the wire connector from the<br />
motor.<br />
Motor Connector<br />
3-14<br />
5. To remove the ambient bimetal:<br />
a) Unclip the bimetal from the compressor<br />
process stub. NOTE: When reinstalling<br />
the bimetal on the process stub, keep<br />
the bimetal as close to the compressor<br />
as possible.<br />
b) Follow the instructions supplied with<br />
the replacement bimetal to connect it to<br />
the unit.<br />
Ambient<br />
Bimetal