9 TECHNICAL DATA (Ctd.)<br />

FREQUENCY FREQUENCY RESPONSE<br />

RESPONSE<br />

• These values for any level to maximum output level<br />

• +/- 0.1 dB, 10Hz - 20 kHz<br />

• +/- 0.5 dB, 10Hz – 100 kHz<br />

• +/- 1.5 dB, 10Hz – 200 kHz<br />

CIRCUIT CIRCUIT SPEED<br />

SPEED<br />

• Slew rate of the amplification stages: 60 V/us<br />

• Rise time: < 200 ns.<br />

GROUP GROUP DE DELAY DE LAY<br />

• Propagation delay < 1 ms stable with frequency from DC to 100 kHz.<br />

DISTORTION<br />

DISTORTION<br />

• With 1 Vrms output level, 80 KHz measurement bandwidth, 600 Ohms termination<br />

impedance<br />

• THD unbalanced in to balanced out 0.01 % flat with frequency<br />

• IMD unbalanced in to balanced out 0.01 %<br />

OPERATING OPERATING TEMPERATURE<br />

TEMPERATURE<br />

• Room temperature: -30 to +40 degrees Celsius (-22 to +104 degrees Fahrenheit).<br />

• Internal temperature: +45 to +65 degrees Celsius (+113 to +149 degrees<br />

Fahrenheit).<br />

GOLDMUND METIS 3 – ANALOG POWER AMPLIFIER - 11