PHL-H11_INT.QXD 16-07-2004 10:42 Pagina 11.1<br />

<strong>Lighting</strong> <strong>controls</strong>


PHL-H11_INT.QXD 16-07-2004 10:42 Pagina 11.2<br />

11.2 LIGHTING CONTROLS


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.3<br />

Health and well being – Total cost of ownership<br />

The benefits of lighting <strong>controls</strong><br />

Modern lighting <strong>controls</strong> deliver a range of benefits, most of which<br />

can be measured in real improvements to the profits of a business.<br />

From straightforward energy savings, through reduced maintenance<br />

costs to potential increases in productivity, lighting <strong>controls</strong> have<br />

clearly demonstrated their worth.<br />

Over the past 25 years Philips lighting <strong>controls</strong> have developed a full<br />

range of solutions designed to deliver these benefits.<br />

Energy Saving<br />

No business likes to be seen to be wasteful. <strong>Lighting</strong> <strong>controls</strong> ensure<br />

that lighting is only provided when and where it is needed.Advanced<br />

sensors are used to integrate daylight and to detect occupancy.These<br />

solutions have been shown to reduce lighting use by as much as 75%.<br />

Result-no obvious waste or compromise of comfort.<br />

Installation Cost Saving<br />

Occupancy sensors and wireless infra-red <strong>controls</strong> avoid the use of<br />

wired switches. Control products compatible with a ‘plug-in’<br />

approach to installation can save up to 70% of the ‘on-site’ labour<br />

time.And these savings continue during the life of the building<br />

whenever changes are needed.<br />

Comfort<br />

In business today the provision of a comfortable environment for<br />

people to learn, work, shop, eat, rest and play is vital for success.<br />

With Philips’ <strong>controls</strong>, the lighting can be set to suit the task, the<br />

experience, individual preferences and tge required mood – and then<br />

readily change them as well.<br />

Safety<br />

There is an increasing awareness of safety and well being, with a<br />

growing emphasis on the importance of emergency lighting.<br />

Flexibility<br />

It is said that the only certainty in life is that things will change.Any<br />

building that cannot be readily adapted to changing business needs<br />

and use is not acceptable today. Philips lighting <strong>controls</strong> are designed<br />

to facilitate change-rapidly and effectively–whatever the application.<br />

Meeting Legislation<br />

Climate change, as well as health and safety are provoking<br />

governments into making more and more regulations, standards and<br />

legislation. Often lighting alone will not easily meet these demands<br />

without the addition of a control solution. In this field, Philps lighting<br />

<strong>controls</strong> has unrivalled knowledge and experience to share.<br />

Maintenance<br />

The easier it is to maintain a lighting installation the lower the cost<br />

of ownership.A Philips lighting management solution can extend lamp<br />

life, provide regular maintenance schedules and report on the<br />

condition of emergency lights. Our lighting management solutions<br />

ensure that exit route lighting is maintained during periods of<br />

occupancy and emergency lighting is effectively tested and<br />

monitored.<br />

LIGHTING CONTROLS<br />

11.3


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.4<br />

<strong>Lighting</strong> <strong>controls</strong> – Key features<br />

E<br />

Automatic control<br />

1. Movement detection<br />

To control lighting within a specific area, sensing of occupancy by<br />

movement detection ensures that lights are activated only when<br />

needed.<br />

2. Daylight linking<br />

Natural light is energy-saving and beneficial to individual users. Light<br />

output can respond to daylight conditions, maintaining a constant level<br />

of indoor lighting and ensuring comfort at all times.<br />

3.Time schedule<br />

Daily programming of the management of lighting installations enables<br />

the correct lighting levels to be achieved at all times, by changing<br />

lighting levels, by switching lights on and off or by adjusting the way<br />

control systems respond to other devices.<br />

Manual control<br />

4. Pushbuttons/wall switches<br />

<strong>Lighting</strong> Control systems can also be operated manually by connecting<br />

conventional wall switches or pushbuttons to inputs in the lighting<br />

control module.<br />

5. Infrared remote control<br />

In offices and meeting rooms where the lighting requirements change<br />

frequently, wireless infrared control offers the flexibility to set the<br />

lighting, and change it at any time.<br />

6. PC control via IT network (TCP/IP)<br />

For high-level lighting management, the control system can be linked to<br />

a LAN. This option gives individual users’ control over their local<br />

working environment.<br />

7.Telephone handset control (via PABX)<br />

To enhance individual comfort, telephones can be connected to a<br />

lighting management system for a cost-effective way of letting users<br />

control their local lighting.<br />

Monitoring<br />

8. Hours run logging<br />

Keep track of lamp hours and produce precisely targeted relamping<br />

schedules and detailed departmental cost allocations.<br />

9. Emergency lighting test and monitor<br />

<strong>Lighting</strong> management systems offer a reliable way to carry out statutory<br />

testing of emergency and exit lighting, without interfering with the<br />

normal operation of standard luminaires.<br />

10. Current lighting status<br />

The ability to get a real-time view of the status of all the lights in a<br />

building on a floor-by-floor basis enhances effective facility management.<br />

11.4 LIGHTING CONTROLS<br />

DMX<br />

<strong>Lighting</strong> effects<br />

11. Maintained illuminance<br />

Set desired light levels and maintain them throughout the life of the<br />

lamp to achieve significant cost savings.<br />

12. Dimming control<br />

As more and more light sources can be economically dimmed, lighting<br />

<strong>controls</strong> need to provide both switching and dimming capabilities.<br />

13. Grouping of lighting circuits<br />

Managing a comfortably lit interior often involves one group of lights<br />

influencing the status of another circuit.<br />

14. Corridor linking<br />

Holding lights on in common circulation areas and corridors during all<br />

occupied hours is an important contribution to comfort and safety.<br />

15. Scene-setting<br />

To meet the needs of different tasks, events or moods, a selection of<br />

lighting scenes can be created, stored and recalled at the touch of a<br />

button.<br />

16. Control of any lighting type<br />

As lighting designs often require multiple types of lamps, <strong>Lighting</strong><br />

Controls provide the freedom to choose any suitable lamps.<br />

17. Colour changing<br />

The ability to change the colour temperature of a lighting installation<br />

makes it possible to eather create a more comfortable working<br />

environment or introduce dynamic lighting effects in architecture.<br />

System connectivity<br />

18. Link to other building <strong>controls</strong><br />

The <strong>Lighting</strong> Controls product range includes numerous possibilities for<br />

different building control and management systems to share information<br />

and functions.<br />

19. Full LonWorks ® Interoperability<br />

Achieve seamless integration into building-wide control systems by<br />

using a standard network protocol.<br />

20. Digital Adressable <strong>Lighting</strong> Interface<br />

The Digital Addressable <strong>Lighting</strong> Interface is the latest standard control<br />

interface for high-frequency electronic ballasts. With this new<br />

technology, control circuits are completely independent of supply<br />

wiring.<br />

21. DMX interface<br />

The standard protocol for the audio/visual and theatre industry. This<br />

interface links complex lighting scenes to presentations and displays.


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.5<br />

<strong>Lighting</strong> <strong>controls</strong> – System selection matrix<br />

Philips offers a range of innovative lighting control products that<br />

meet the demands of many sizes and types of application.Whether<br />

the project is a large HQ office building, requiring a full lighting<br />

management system, or a small refurbishment job involving a couple<br />

of rooms, there is a Philips lighting control to suit the application.<br />

When matching your project to our lighting control products use<br />

the following criteria as your initial guide to product selection:<br />

E<br />

DMX<br />

Systems Stand alone Luminaire based<br />

Helio Lightmaster Scenio 100 Scenio<br />

Trios<br />

MultiDim<br />

Occuswitch<br />

Intelligent<br />

luminaires<br />

Linesense<br />

Automatic control page 11.15 page 11.16 page 11.27 page 11.31<br />

page<br />

11.30/11.26<br />

page 11.10 page 11.6 page 11.28<br />

Movement detection • • • • • • • •<br />

Daylight linking • • • • •<br />

Time schedule • • •<br />

Manual control<br />

Push buttons/switches • • • • • •<br />

Infrared remote control • • • • • • •<br />

PC control • • o<br />

Telephone control via PABX o<br />

Monitoring<br />

Hours run logging o •<br />

Emergency testing and logging o •<br />

<strong>Lighting</strong> effects<br />

Maintained illuminance • • • • •<br />

Switching and dimming • • • • • • •<br />

Grouping functionality • • • •<br />

Corridor linking • •<br />

Scene setting • • • • • •<br />

Control of any lighting type • • • • • •<br />

Colour changing o o • •<br />

System Connectivity<br />

• The functionality required – dimming, flexibility ….<br />

• The scale of the project (and hence its budget…)<br />

• The application – office, hotel, shop, industry, etc.<br />

Other factors to bear in mind include the choice of lighting design as<br />

well as any requirement for local user <strong>controls</strong> and/or occupancy<br />

response.<br />

Link to other building mgt. syst. • • •<br />

Full LonWorks ® interoperability •<br />

Digital Adressable <strong>Lighting</strong> Interface • • o • • •<br />

DMX interface •<br />

• standard option o project special<br />

LIGHTING CONTROLS 11.5


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.6<br />

Luminaire based and basic solutions<br />

Philips intelligent luminaires –<br />

The simplest way to lighting control<br />

To increase comfort, energy saving and flexibility in offices, Philips has<br />

incorporated miniature lighting <strong>controls</strong> within the luminaires.<br />

Philips <strong>Lighting</strong> offers a choice of intelligent luminaire solutions that<br />

provide a wide range of functions such as daylight linking, movement<br />

detection, remote control and scene setting with energy savings of<br />

up to 70%. Intelligent luminaires enable lighting control to be applied<br />

in a building at any stage of a project.The sensor-controller<br />

combination within the luminaire has little impact, or none at all, on<br />

the electrical installation.<br />

Omnisense – All intelligence in one<br />

Primarily designed for cellular and smaller open plan offices,<br />

Omnisense can also be applied in other areas such as meeting<br />

rooms, toilets and storage rooms. By using the benefits of digital<br />

technology, Omnisense provides 10 pre-programmed modes to<br />

match a variety of applications quickly and easily. Each mode includes<br />

a varies parameters such as delay times and switching behaviour. In<br />

addition to daylight regulation and movement detection, infrared<br />

remote control enables users to interact with their environment:<br />

switch, dim or select preset lighting levels or scenes. Omnisense<br />

functionality can be changed easily so that its behaviour can be<br />

adapted to new situations.<br />

11.6 LIGHTING CONTROLS<br />

Occulux – Movement-dependent daylight regulation<br />

As a combination of a state-of-the-art light sensor and a miniature<br />

movement detector, Occulux regulates lighting levels depending on<br />

the amount of daylight entering a room and on occupation.The<br />

increasing need for flexibility means that lights often remain on<br />

unnecessarily. On the other hand, turning lights off in certain areas of<br />

an open plan office can create an unpleasant visual impression.<br />

Occulux therefore dims light down to a minimum lighting level when<br />

an area is unoccupied.The result is a constant, pleasant lighting level<br />

for office workers with a maintained adjustable minimum, enabling<br />

owners to benefit from considerable savings on energy costs of up<br />

to 50%.<br />

Luxsense – Daylight-dependent regulation option<br />

Luminaires with this option contain a unobtrusive light sensor,<br />

regulating light to the required level depending on the amount of<br />

daylight. Energy saving results from both the use of daylight and the<br />

compensation of the over-design effect (maintained illuminance).<br />

With today’s efficient lamps and optics, the compensation of the<br />

over-design is very effective, particularly in retrofit projects.Average<br />

energy savings can reach up to 35%. Luxsense is also available as a<br />

separate product for both TL5 and TL-D luminaires.


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.7<br />

Occuswitch – <strong>Lighting</strong> control the easy way<br />

The Occuswitch is a very simple occupancy type controller that<br />

provides automatic switching of lighting loads of up to 10A.A built-in<br />

adjustable time delay allows the lights to remain on after occupancy<br />

for a selected period of time.An optional light sensor is also built-in<br />

so that if the natural daylight conditions are sufficient the lights will<br />

not switch on thus saving more energy.<br />

The Occuswitch distinguishes itself in design, quality and ease of<br />

installation; it is simply positioned in the middle of the room or area,<br />

the mains power supply wired directly to it and the luminaire circuit<br />

wired from it. Simplicity at its best! Occuswitch is ideally suited for<br />

those areas that are infrequently occupied and where dimming is not<br />

required - such as washrooms, stores, lobbies, corridors, cellular<br />

offices and meeting rooms.A version with manual IR remote<br />

override control is also available.<br />

Occuswitch<br />

LIGHTING CONTROLS 11.7


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.8<br />

<strong>Lighting</strong> <strong>controls</strong> Omnisense, Occulux, Luxsense<br />

11.8 LIGHTING CONTROLS<br />

LRI1661<br />

Omnisense<br />

- Easy selection of 10 building application modes<br />

with commissioning tool IRT8099<br />

- Mounting height: approx. 3 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy adjustment of required light level with<br />

commissioning tool<br />

- Movement detection area 20 m 2<br />

- Master-slave installation: up to 7 DALI luminaires<br />

can be slaved to 1 luminaire equipped with<br />

Omnisense provided they all remain in the<br />

movement detection area<br />

- Reliable Philips RC5 infrared protocol<br />

- Can be used with or without bracket, depending<br />

on luminaire type<br />

- Available as option for many luminaires<br />

LRI1340<br />

Occulux<br />

- Mounting height: approx. 3 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy manual adjustment of minimum light level<br />

during absence<br />

- Movement detection area 20 m 2<br />

- Master-slave installation: up to 7 HFR luminaires<br />

can be slaved to 1 luminaire equipped with<br />

Occulux provided they all remain in the movement<br />

detection area<br />

- Can be used with or without bracket, depending<br />

on luminaire type<br />

- Available as option for many luminaires<br />

LRL1220<br />

Luxsense<br />

- Mounting height: 2-4 m<br />

- Default setting light level: 500 - 600 lux<br />

- Easy manual adjustment of required light level<br />

IRT8099<br />

Commissioning tool for Omnisense luminaires.<br />

Easy to use and inexpensive tool to adjust light<br />

levels and to switch between functionality modes.<br />

Batteries are included.<br />

Product ID European Order<br />

Code (EOC)<br />

IRT8099/00 51889300<br />

~LIGHTM~Lightmaster


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.9<br />

<strong>Lighting</strong> <strong>controls</strong><br />

LIGHTING CONTROLS 11.9


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.10<br />

<strong>Lighting</strong> <strong>controls</strong> Occuswitch<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRM1050/00 SENSR MOV DET ST 0.26 51725400<br />

LRM1051/00 SENSR MOV DET PLUG 0.34 51732200<br />

LRM1060/00 SENSR MOV DET ST IR 0.26 51734600<br />

LRM1061/00 SENSR MOV DET PLUG IR 0.34 51736000<br />

11.10 LIGHTING CONTROLS<br />

Dimensions in mm<br />

~HELIO~Helio lighting management system<br />

LRM1050/00<br />

Movement detector with built-in lighting switch.The<br />

unit is designed for the automatic switching of<br />

lighting in indoor applications. Connection: Screw<br />

terminals. Switch-off delay time from 1 to 35 min.<br />

(selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).<br />

LRM1051/00<br />

Movement detector with built-in lighting switch.The<br />

unit is designed for the automatic switching of<br />

lighting in indoor applications. Connection: Wieland<br />

connectors GST 18-3 male/female. Switch-off delay<br />

time from 1 to 35 min. (selectable).The pattern of<br />

sensitivity is nearly circular; covering an area with a<br />

diameter of about 7 m. Mounting height 2.5 to 3 m.<br />

Daylight-override 10 to 1000 lux (selectable), factory<br />

set at 750 lux. Max. switching current 10 A rms (any<br />

load).<br />

LRM1060/00<br />

Movement detector with built-in lighting switch and an<br />

infrared receiver, enabling manual control<br />

(OVERRIDE).The unit is designed for the automatic<br />

switching of lighting in indoor applications. Connection:<br />

Screw terminals. Switch-off delay time from 1 to<br />

35 min. (selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).<br />

LRM1061/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(OVERRIDE).The unit is designed for the automatic<br />

switching of lighting in indoor applications.<br />

Connection: Wieland connectors GST 18-3<br />

male/female. Switch-off delay time from 1 to 35 min.<br />

(selectable).The pattern of sensitivity is nearly<br />

circular; covering an area with a diameter of about<br />

7m.Mounting height 2.5 to 3 m. Daylight-override<br />

10 to 1000 lux (selectable), factory set at 750 lux.<br />

Max. switching current 10 A rms (any load).


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.11<br />

<strong>Lighting</strong> <strong>controls</strong> Occuswitch<br />

ASSOCIATED PRODUCTS<br />

Dimensions in mm<br />

IRT8010/00 LRH8010/00<br />

IRT8050/00<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRM1064/00 SENSR ABS DET ST IR 0.26 51755100<br />

LRM1065/00 SENSR ABS DET PLUG IR 0.34 51757500<br />

IRT8010/00 TRANSM IR POINT 0.06 51749000<br />

LRH8010/00 MOUNT IR POINT 0.03 51797100<br />

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000<br />

LRM1064/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(MANUAL SWITCH ON).The unit is designed for<br />

the automatic switching of lighting in indoor<br />

applications. Connection: Screw terminals. Switch-off<br />

delay time from 1 to 35 min. (selectable).The<br />

pattern of sensitivity is nearly circular; covering an<br />

area with a diameter of about 7 m. Mounting height<br />

2.5 to 3 m. Daylight-override 10 to 1000 lux<br />

(selectable), factory set at 750 lux. Max. switching<br />

current 10 A rms (any load).<br />

LRM1065/00<br />

Movement detector with built-in lighting switch and<br />

an infrared receiver, enabling manual control<br />

(MANUAL SWITCH ON).The unit is designed for<br />

the automatic switching of lighting in indoor<br />

applications. Connection: Wieland connectors<br />

GST 18-3 male/female. Switch-off delay time from<br />

1 to 35 min. (selectable).The pattern of sensitivity is<br />

nearly circular; covering an area with a diameter of<br />

about 7 m. Mounting height 2.5 to 3 m. Daylightoverride<br />

10 to 1000 lux (selectable), factory set at<br />

750 lux. Max. switching current 10 A rms (any load).<br />

LIGHTING CONTROLS 11.11


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.12


PHL-H11_INT.QXD 16-07-2004 10:43 Pagina 11.13<br />

<strong>Lighting</strong> management<br />

The working environment<br />

People think and work better in a comfortable environment, which<br />

leads to better productivity.Today's office buildings need to be<br />

adaptable to the needs of both individual users and the companies<br />

they work for.A networked lighting management system is an<br />

essential part of a modern lighting installation.<br />

Flexibility<br />

Change - in a modern building this can happen every day. Philips'<br />

lighting management systems have been developed with change in<br />

mind. From the easily installed hardware to the user-friendly local<br />

override facilities these solutions make change much easier to deal<br />

with, while still delivering the individual lighting levels chosen by the<br />

staff.<br />

LIGHTING CONTROLS 11.13


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.14<br />

LightMaster<br />

LightMaster – Networked lighting management<br />

LightMaster is a family of networked lighting <strong>controls</strong>, which are very<br />

attractive to budget-conscious users, designers and installers.<br />

LightMaster components are built into a simple, yet highly flexible<br />

networked lighting control and monitoring system, that also offers<br />

simple and effective integration possibilities.<br />

With building use changing regularly, often within months, the<br />

expense of reconfiguration is now an important factor for every<br />

building operator.This system is specifically designed to facilitate any<br />

required changes in the lighting installation through the powerful yet<br />

easy-to-use LightManager software suite. Monitoring facilities range<br />

from simple status indication to sophisticated event and run-time<br />

logging.<br />

1. Intial configuration<br />

11.14 LIGHTING CONTROLS<br />

9-output LCM, switching<br />

and dimming<br />

Luminaire<br />

2. Changed configuration (lay-out)Caption<br />

User-friendly graphics<br />

LightManager is both the configuration tool and the user interface<br />

for LightMaster.The package is specifically designed to run under<br />

Microsoft Windows, ensuring that it has a familiar ‘look and feel’ to<br />

welcome the user. Building plans and lighting layouts are imported<br />

from AutoCAD or other industry-standard design packages.These<br />

files then become the foundation of the lighting control system’s<br />

supervisory software. Easily understood icons that give absolute<br />

clarity to the facilities management team illustrate all the lighting<br />

system components.<br />

Multi-sensor<br />

Wall switch


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.15<br />

Helio<br />

Helio - Innovation by integration<br />

Helio is a lighting control system for building-wide control, which can<br />

become an integral part of the building management concept using<br />

one network. Its open system architecture, open communications<br />

protocol and standardised technology allow Helio to be easily<br />

integrated with systems supplied by different vendors such as<br />

heating, ventilation, window blinds, building access and more.<br />

2-output LCM<br />

8-output LCM, either switching<br />

only or switching and dimming<br />

Luminaire<br />

LON multi-sensor or<br />

conventional<br />

(multi-) sensor<br />

1. Get ready for integration<br />

InfraRed receiver<br />

Heating & ventilation<br />

controller<br />

Sunblind controller<br />

2. Take control with sensors,<br />

transmitters and pushbuttons<br />

Integration on all levels<br />

Helio is based on Echelon’s LonWorks® technology, the de facto<br />

standard for leading suppliers of building services <strong>controls</strong>. Plug-ins<br />

for other tools, such as LonMaker for Windows®, are also provided.<br />

As a result Helio offers numerous solutions for lighting and<br />

integration, driven by users’ demands for investment benefits,<br />

functionality and upgradeability.Three levels of lighting solutions give<br />

you virtually unlimited possibilities.These range from a<br />

basic solution for centralised lighting control, through<br />

a system with more advanced control functions using<br />

sensors, transmitters and pushbuttons, to a fully<br />

integrated approach to building <strong>controls</strong>.<br />

3. Complete integration<br />

with HVAC systems and sunblinds<br />

LIGHTING CONTROLS 11.15


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.16<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LBC5000/00 SOFTW A62PC+SOFTW 4.00 53552400<br />

LBC5001/02 SOFTW CARD+SOFTW 0.15 53734400<br />

LFC5255/00 NETWK AREA CONTR 2.44 53932400<br />

11.16 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LRH5300/50 CONTR BASE ASSY PLUG 1.26 53422000<br />

LLC5319/50 CONTR 9X4 PLUG SW&RE 1.71 53460200<br />

LLC5319/70 CONTR 9X4 PLUG SW&RE D-NO 1.00 53710800<br />

LLC5319/71 CONTR 9X4 PLUG SW&RE D-LIM 1.80 53762700<br />

LLC5359/50 CONTR 9X4 PLUG SW&RE RC5 1.71 53930000<br />

~LIGHTM~Lightmaster<br />

LBC5000/00<br />

Central Supervisor. IBM compatible PC with<br />

software and interface card, user interface to the<br />

LM100 system. A Central Supervisor can control up<br />

to 60 Area Controllers.<br />

Also available:<br />

LBC5001/02 Interface Card and LightManager<br />

Software to be used with a PC provided by the<br />

client.<br />

LFC5255/00<br />

Area Controller. A building controlled by a LM100<br />

system is split into a number of areas. Each area is<br />

supervised with an Area Controller.The Area<br />

Controller manages network traffic, schedules time<br />

commands and implements re-configuration<br />

commands from the Central Supervisor.<br />

LRH5300/50<br />

Base to be used with LLC5319 <strong>Lighting</strong> Control<br />

Modules.<br />

LLC5319<br />

Pluggable <strong>Lighting</strong> Control Module with 4 inputs and<br />

9 outputs (Wieland GST). Each output can be<br />

configured to control any light or combination of<br />

lights anywhere on the system. Each individual<br />

output is allowed to switch up to 4 A, with a<br />

maximum for all outputs up to 10 A divided over<br />

the two sides, each 5 A. Requires the LRH5300/50<br />

base to be mounted on.<br />

Versions available:<br />

LLC5319/50 Pluggable LCM (1-10V).<br />

LLC5319/70 Pluggable LCM for use with DALI<br />

ballasts (no feedback).<br />

LLC5319/71 Pluggable LCM for use with DALI<br />

ballasts (limited feedback).<br />

LLC5359/50 Pluggable LCM (1-10V) for use with<br />

RC5 IR remote control.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.17<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LLC5314/50 CONTR 4X4 ST SW&RE 0.89 53572200<br />

LRH5304/50 CONTR BASE ASSY ST 2.14 53590600<br />

LLC5702/50 CONTR 2X2 GT SW&RE 0.36 53574600<br />

LLC5702/41 CONTR 2X2 GT SW&RE TIN 1.37 53412100<br />

LLC5702/42 CONTR 2X2 GT SW&RE 2TIN 1.72 53413800<br />

LLC5702/72 CONTR 16X2 GT SW&RE D 0.40 53756600<br />

LLC5702/73 CONTR 16X2 GT SW&RE IN 1.37 53758000<br />

LLC5314/50<br />

<strong>Lighting</strong> Control Module with screw terminals for<br />

4 inputs and 4 outputs (1-10 V).This unit is used to<br />

control circuits of lights. Each input can be<br />

configured to control any light or combination of<br />

lights anywhere on the system. Requires the<br />

LRH5304/50 Base to be mounted on. Dimension<br />

drawing includes the base (LRH5304/50).<br />

LRH5304/50<br />

Base to be used with LLC5314/50 <strong>Lighting</strong> Control<br />

Module. Dimension drawing includes the lighting<br />

control module (LCC5314/50).<br />

LLC5702/50<br />

Separate Gear Tray <strong>Lighting</strong> Control Module. Can be<br />

mounted inside a luminaire or switch cabinet.<br />

1-10V analogue dimming.<br />

LLC5702/72 Gear Tray <strong>Lighting</strong> Control Module,<br />

with single DALI output, 16 addresses and feedback,<br />

2 inputs.<br />

LLC5702<br />

Gear Tray <strong>Lighting</strong> Control Module with terminals<br />

for 2 outputs and 2 inputs in metal enclosure. Each<br />

input can be configured to control any light or<br />

combination of lights anywhere on the system.<br />

Versions available:<br />

LLC5702/41 1 Gear Tray <strong>Lighting</strong> Control Module in<br />

metal enclosure.<br />

LLC5702/42 2 Gear Tray <strong>Lighting</strong> Control Modules<br />

in 1 metal enclosure.<br />

LLC5702/73 1 Gear Tray <strong>Lighting</strong> Control Module in<br />

metal enclosure with one DALI output, 16 addresses<br />

and feedback, 2 inputs.<br />

LIGHTING CONTROLS 11.17


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.18<br />

<strong>Lighting</strong> <strong>controls</strong> Lightmaster<br />

11.18 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LLC5714/00 CONTR 0X4 DIN 0.28 53414500<br />

LLC5714/41 CONTR 0X4 DIN TIN 1.70 53416900<br />

LLC5724/50 CONTR 4X0 DIN SW&RE 0.47 53578400<br />

LLC5724/41 CONTR 4X0 DIN SW&RE TIN 1.84 53417600<br />

LLC5714/00<br />

Input Module for DIN Rail mounting.<br />

LLC5714/41<br />

Input Module with 4 inputs in metal enclosure.<br />

Allows the connection of 4 sensors or switches.<br />

Each sensor or switch can be configured to control<br />

any light or combination of lights anywhere on the<br />

system.<br />

LLC5724/50<br />

Output Module for DIN Rail mounting.<br />

LLC5724/41<br />

Output Module with 4 outputs in metal enclosure.<br />

It has screw terminals for 4 light circuits. Each of the<br />

outputs can be addressed individually.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.19<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC5040/10 CONTR 1x1 ST SW&RE 0.47 51625700<br />

LRC5042/00 CONTR 2x1 ST SW&RE 1.10 51727800<br />

LRC5043/00 CONTR 2x2 ST SW&RE 1.20 53708500<br />

LRC5038/10 CONTR 8x4 PLUG S 1.48 53740500<br />

~HELIO~Helio lighting management system<br />

LRC5040/10<br />

Helio light controller with single channel for<br />

switching and regulating lighting loads up to 5 A, and<br />

providing a sensor interface for standard IR<br />

receivers, pushbutton interface units, movement<br />

detectors, and light sensors.<br />

LRC5042/00<br />

Helio light controller with two separately controlled<br />

outputs and one interface for standard movement,<br />

light and infrared sensors.The outputs are able to<br />

switch and regulate lighting loads up to 5 A.The<br />

outputs and LON bus have screw connections, the<br />

sensor interface is connected via RJ12 plug.<br />

LRC5043/00<br />

Helio light controller identical to the LRC5042 but<br />

with two sensor interfaces for standard movement<br />

detectors, lights sensor and IR receiver and two<br />

inputs for standard wall switches.The outputs have a<br />

6-pole screw conector that provides Live, Neutral,<br />

Protective Earth, Maintained live for power supply to<br />

batteries in emergency luminaires and a + and - for<br />

1- 10 V dimming.<br />

LRC5038/10<br />

Helio light controller with eight switchable outputs,<br />

two pairs of sensor interfaces for standard<br />

movement detectors, light sensors, IR receivers and<br />

two inputs for standard wall switches.The outputs<br />

are able to switch lighting loads up to 4 A.The unit<br />

has a maximum total rating of 10 A divided over the<br />

two sides, each 5 A. Each output has a 3-pole<br />

Wieland socket (GST) that provides Live, Neutral<br />

and Protective Earth.<br />

LIGHTING CONTROLS 11.19


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.20<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC5048/00 CONTR 8x4 PLUG SW&RE 3.00 51688200<br />

LRI5133/10 SENSR LON MULTISENSOR 0.30 51684400<br />

11.20 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LRC5048/00<br />

Helio light controller with eight separately controlled<br />

outputs and two interfaces for standard movement<br />

detectors, light sensors and pushbutton switches.The<br />

outputs are able to switch and regulate lighting loads<br />

up to 5 A.The unit has a maximum total rating of<br />

16 A. Each output has a 6-pole Wieland socket<br />

(GST) that includes a maintained live for power<br />

supply to batteries in emergency luminaires. Battery<br />

performance can then be tested by interrupting the<br />

maintained power supply at prescribed intervals.<br />

LRI5133/10<br />

Helio multi-sensor with movement detector, light<br />

sensor, and infrared receiver used for remote and<br />

automatic control of lighting, HVAC and sun blind<br />

functions in integrated room control applications.The<br />

IR receiver can be combined with hand-held and wall<br />

transmitters for remote control operations and with<br />

wall transmitters with built-in temperature sensors for<br />

automatic temperature control. Units are connected<br />

directly to LonWorks ® bus cable for network<br />

communication and power supply.Their functional<br />

behaviour can adapted by downloading project<br />

specific software over the bus.<br />

Mounting plate for surface mounting of LRI5133.<br />

This plate is packed together with the sensor itself.<br />

Mounting ring for recessed mounting of LRI5133.<br />

This ring is packed together with the sensor itself.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.21<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LCU5305/00 NETWK 2x2 DIG I/O 0.20 51614100<br />

LCU5315/20 NETWK CLOCK 0.20 51615800<br />

LCN5225/00 NETWK POWER 0.60 51611000<br />

LCN5235/00 NETWK REPEATER 0.60 51612700<br />

LCU5305/00<br />

Helio digital I/O module providing a simple dry<br />

contact interface to and from various systems.<br />

The unit has 2 inputs and 2 outputs.<br />

LCU5315/20<br />

Helio system clock providing a real time clock and<br />

programmable switching schedule.<br />

LCN5225/00<br />

Helio bus power supply unit providing a voltage of<br />

42 V DC and a current of 1.4 A to the linkpower<br />

bus.The bus voltage and current is used by devices<br />

using LPT transceivers like Helio sensors, system<br />

clocks and digital I/Os.<br />

LCN5235/00<br />

Helio bus power supply/repeater regenerating bus<br />

communication and providing power to the bus.<br />

LIGHTING CONTROLS 11.21


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.22<br />

<strong>Lighting</strong> <strong>controls</strong> Helio lighting management system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LCN5245/00 NETWK ROUTER 0.60 51613400<br />

LCC5301/00 CABLE BUS 100M 0.01 51714800<br />

LCS5425/00 SOFTW UNILON CLIENT 0.10 51758200<br />

LCS5430/00 SOFTW UNILON SERVER 0.60 51756800<br />

LCS5435/00 SOFTW UNILON TRAIN 0.60 51849700<br />

LCS5495/00 SOFTW UNILON CREDIT - 51759900<br />

11.22 LIGHTING CONTROLS<br />

Dimensions in mm<br />

LCN5245/00<br />

Helio bus power supply/router repeater<br />

regenerating and managing bus communication and<br />

providing power to the bus.<br />

LCC5301/00<br />

<strong>Lighting</strong> control busline, used to interconnect all<br />

system components of the Helio lighting<br />

management system.<br />

The busline carries all data exchange between the<br />

various "modules" of Helio.<br />

The LCC5301 is a cable of 100 m without<br />

connectors.<br />

Unilon software.<br />

Unilon is a general configuration tool for<br />

LonWorks ® based systems. It offers a fully graphical<br />

user interface and many other features for<br />

commissioning of LonWorks ® systems. Each actual<br />

installation of one node in a network requires a<br />

license, so-called credit key. Unilon is now available in<br />

client and server version. Credits can be separately<br />

ordered in variable amounts.The server package<br />

includes documentation files about Helio and<br />

Unilon.<br />

Helio LNS Plug-ins.<br />

Plug-ins for other configuration tools like<br />

LonMaker for Windows are also available. For<br />

more information please contact your local Philips<br />

<strong>Lighting</strong> Controls representative.


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.23<br />

<strong>Lighting</strong> <strong>controls</strong><br />

LIGHTING CONTROLS 11.23


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.24


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.25<br />

Architecture and shops<br />

Versatile control range<br />

Scenio100 / MultiDim is a scene setting lighting control range that<br />

cover a wide range of applications. It provides from simple to<br />

comprehensive control facilities at the touch of a button.With an<br />

easy-to-use remote control different preset scenes can be<br />

programmed and selected, changing the mood of the room in<br />

seconds.<br />

Creative lighting design<br />

With its capacity to control a large number of channels of lighting,<br />

the Scenio100 / MultiDim range is ideally suited for applications using<br />

many different types of luminaries for incandescent, halogen and<br />

fluorescent lamps. In addition Scenio100 / MultiDim can also be used<br />

to switch on projectors, lower projection screens or close window<br />

blinds at just the touch of a button.<br />

Scene setting for all occasions<br />

The Scenio100 / MultiDim product range can be applied in situations<br />

such as conference halls, boardrooms, lecture theatres, hotel<br />

functions rooms, museums, showrooms, cafes, restaurants and shops.<br />

Caption<br />

Shoebaloo, Amsterdam<br />

Colours set the mood and add emotion<br />

LIGHTING CONTROLS 11.25


PHL-H11_INT.QXD 16-07-2004 10:44 Pagina 11.26<br />

MultiDim<br />

Digital control solution<br />

Philips DALI MultiDim offers today’s most versatile and easy-toinstall<br />

solution that brings the benefits of digital lighting control to<br />

many different application areas.Whether in shops, offices,<br />

conference rooms, hotels, restaurants or other applications.<br />

Quick and economic installation<br />

MultiDim consists of an integrated range of DALI-compatible devices<br />

that can be combined flexibly to create exactly the desired control<br />

functions.The systems addressable digital architecture means that<br />

only a single two-core cable is needed to interconnect all units.The<br />

possibility to eliminate conventional vertical wall wiring both reduces<br />

installation time and cost, and greatly increases the ease with which<br />

later changes can be implemented.<br />

MultiDim product range<br />

11.26 LIGHTING CONTROLS<br />

Freedom in lighting design<br />

MultiDim offers unbeatable freedom and ease of lighting system<br />

design.The MultiDim controllers can be used in combination with<br />

DALI-compatible fluorescent lamp ballasts and lamp interface units<br />

(both high voltage incandescent lamps and low voltage halogen<br />

lamps).Where necessary control functions can be provided by adding<br />

the required MultiDim units such as dimmers, control panels, IR<br />

remote control units and multi sensors for light levels and room<br />

occupancy.<br />

Maximising flexibility with DALI<br />

Thanks to the systems digital addressable control and<br />

communication concept, each unit in the DALI network has its own<br />

unique address that allows it to be switched and controlled<br />

independently.The systems single control line can be used to control<br />

different groups of lamps, and up to 63 devices connected to the<br />

same physical control wire can be addressed and controlled<br />

independently.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.27<br />

Scenio100<br />

Powerful control solution<br />

Scenio100 enables the lighting designer to achieve the correct<br />

ambience for all occasions. Either simple or advanced effects may be<br />

set at the touch of a button, including dynamic lighting and colour<br />

change as well as daylight linking and time control options. Scenes<br />

are created via software run on a PC, LCD touch screen or by<br />

infrared hand held transmitter.<br />

Flexibility in applications<br />

In retail areas time sequenced scene and colour changing is used to<br />

stimulate sales by highlighting products and creating an exciting<br />

environment. In restaurants Scenio100 provides the right atmosphere<br />

for a light breakfast, a working lunch or an intimate dinner.<br />

Other indoor applications include: museums, exhibition and<br />

conference centres, lecture theatres, leisure centres, stadiums, hotels,<br />

public buildings and prestige homes. Scenio100 is also highly effective<br />

in outdoor applications, particularly floodlighting.<br />

Choice of Dimming Racks<br />

Tungsten, low voltage, LED, cold cathode, fluorescent and all other<br />

dimmable light sources may be controlled using phase cutting, digital<br />

or DC voltage techniques. Dimming modules are built into compact,<br />

standard or custom-built racks, which are connected by a serial data<br />

bus to create a multi-channel control solution. Racks feature a mains<br />

input isolator and circuit breakers for individual output protection, as<br />

well as inputs for serial and DMX control, and voltage free contacts<br />

providing an interface to other building management systems.<br />

Control Interfaces<br />

Scenes can be controlled by LCD touch screen, infrared remote<br />

control and manual button control plate. Control plates with a satin<br />

anodised aluminium finish are standard available, with other<br />

decorative finishes optional available. Partition switches join and<br />

separate the control of rooms with demountable partitions.<br />

For further information about the versatile<br />

Scenio 100 system, please contact your local<br />

Philips <strong>Lighting</strong> representative.<br />

LIGHTING CONTROLS 11.27


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.28<br />

Industry lighting systems - Linesense<br />

<strong>Lighting</strong> <strong>controls</strong> in industry<br />

Industrial buildings today are<br />

models of efficiency in meeting<br />

their specific purpose – be it a<br />

logistics’ warehouse or a major<br />

manufacturing complex. <strong>Lighting</strong> in<br />

these environments plays the<br />

same important role as it does in<br />

any other work place.<br />

Philips industrial lighting control<br />

solutions are specifically intended<br />

to meet the exacting demands of<br />

these buildings to be both cost<br />

effective and well lit facilities.<br />

<strong>Lighting</strong> <strong>controls</strong> for TTX400 light-lines<br />

Today’s warehouses and distribution centres can be characterised by<br />

their large size and the few people employed. Light is switched on all<br />

day although the employees need it only for a limited time. For those<br />

applications Philips <strong>Lighting</strong> offers a stand-alone control solution,<br />

Linesense, to be used in combination with TTX400 light-lines.<br />

Linesense dims or even switches off the lights when nobody is<br />

present in a particular zone.<br />

Linesense extention with movement detector<br />

11.28 LIGHTING CONTROLS<br />

Easy to install<br />

The Linesense range comprises a supplementary 300 mm trunking<br />

element, containing the controller, for addition to the TTX400 light<br />

line.This extra unit is easily installed between the light line and the<br />

electrical connection unit – the “6th click” in the TTX400 system.<br />

High bay movement detectors and, optionally, a light sensor are<br />

simply connected through RJ-12 modular cables to the dedicated<br />

brackets. Once installed, the system works automatically and requires<br />

no extra maintenance.<br />

Energy saving<br />

Linesense, in combination with the highly efficient TTX400<br />

luminaires, decreases energy costs substantially by using presence<br />

detection, daylight linking and manual control.<br />

Examples show that energy savings up to 75% can be achieved.With<br />

Linesense energy savings are realised from day one, with no<br />

additional costs in the long run.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.29<br />

LON-DALI<br />

Digital intelligence for Light-lines<br />

The LON-DALI control system provides optimal lighting where it’s<br />

needed and when it’s needed. Promoting maximum productivity,<br />

comfort and safety.A system, moreover, that’s simple to operate and<br />

to adapt to changing industrial requirements. Providing a unique<br />

solution that truly reflects the needs of modern industry – today and<br />

into the future.<br />

Adaptive to needs and activities<br />

The LON-DALI system allows creating lighting zones within and<br />

across light-lines (TTX400 and Maxos). It offers total flexibility to<br />

control the lighting behaviour of each zone and even to reprogram<br />

the zones into a new lighting arrangement to accommodate changes<br />

in floor layout or production activity. New arrangements can be<br />

software configured with no need for rewiring.<br />

Caption<br />

LON-DALI system solution<br />

Optimal lighting<br />

The system, moreover, accommodates time control, manual control,<br />

movement detection and daylight regulation – resulting in optimal<br />

illumination of all tasks on the factory floor and increasing operator<br />

productivity, efficiency, comfort and safety.<br />

Taking control<br />

The LON-DALI controller allows for status monitoring including<br />

individual lamp and ballast status, burning hours and energy<br />

consumption in each light zone. Ensuring that the light line<br />

installation always functions at optimum efficiency, and allowing for<br />

accurate cost allocation to individual departments using the<br />

installation.The controller provides the means to have this<br />

information to be integrated into a modern Building Management<br />

System.<br />

LRC5140/41- LON-DALI light controller for industry<br />

LIGHTING CONTROLS 11.29


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.30<br />

<strong>Lighting</strong> <strong>controls</strong> Trios system<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LRC1010/10 CONTR 1x1 ST S 0.46 51643100<br />

LRC1020/10 CONTR 1x1 ST SW&RE 0.46 51645500<br />

LRC1030/00 CONTR 1x1 PROG ST SW&RE 0.46 51583000<br />

LRC1015/10 CONTR 1x1 DIN S 0.33 51644800<br />

LRC1025/10 CONTR 1x1 DIN SW&RE 0.33 51646200<br />

LRC1035/00 CONTR 1x1 PROG DIN SW&RE 0.33 51586100<br />

11.30 LIGHTING CONTROLS<br />

Dimensions in mm<br />

~HELIO~Helio lighting management system<br />

LRC1010/10<br />

LRC1020/10<br />

LRC1030/00<br />

Trios multifunctional and addressable light controllers<br />

in a housing for distributed installation in three<br />

versions.The switching (LRC1010) and the<br />

switching/regulating (LRC1020) versions have<br />

pre-defined functionalities that depend on the<br />

connection of movement detector, infrared receiver<br />

and/or light sensor.They are specifically designed for<br />

energy saving solutions with dimmable and<br />

non-dimmable luminaires.The functionality of the<br />

switching and regulating LRC1030 can be adapted<br />

by PC programming software (available separately)<br />

for special lighting control applications. A highly<br />

informative Trios Manual is available to assist<br />

designers and installers in selecting the correct<br />

products for their applications.<br />

LRC1015/10<br />

LRC1025/10<br />

LRC1035/00<br />

Trios multifunctional and addressable light controllers<br />

in a DIN-rail housing for centralised installation in<br />

three versions.The switching (LRC1015) and the<br />

switching/regulating (LRC1025) versions have<br />

pre-defined functionalities that depend on the<br />

connection of a movement detector, infrared<br />

receiver and/or light sensor.They are specifically<br />

designed for energy saving solutions with dimmable<br />

and non-dimmable luminaires.The functionality of<br />

the switching and regulating LRC1035 can be<br />

adapted by PC programming software (available<br />

separately) for special lighting control applications.<br />

A highly informative Trios Manual is available to assist<br />

designers and installers in selecting the correct<br />

products for their applications.<br />

LCS1030/00<br />

Trios Software<br />

Software for use on a PC to alter the parameters of<br />

the LRC1030/1035 controllers.<br />

Trios Handbook<br />

Trios Handbook, intended to assist consultants,<br />

engineers, installers and other professionals involved<br />

in project management and design, and in specifying<br />

and procuring lighting control systems. Its purpose is<br />

to aid the reader in selecting the most effective<br />

lighting solution for a particular application<br />

requirement. It describes the fundamental<br />

technicalities of the Trios system and its associated<br />

components, and gives detailed information on<br />

installation, test and commissioning.<br />

More information: www.<strong>controls</strong>4lighting.com


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.31<br />

<strong>Lighting</strong> <strong>controls</strong> Scenio system<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LRC1555/00 CONTR 1X1 0.35 51653000<br />

LRC1505/00 CONTR 1X0 EXTENSION 0.35 51651600<br />

IRT8020/00 TRANSM IR SCENIO 0.22 51761200<br />

~TRIOS~Trios system<br />

LRC1555/00<br />

Scenio light controller with two modular sockets:<br />

one dedicated for sensors (IR receivers and/or<br />

movement detectors) and the other for businterconnection<br />

to the extension modules LRC1505.<br />

Up to three IR receivers and three movement<br />

detectors can be connected to the sensor input.<br />

The unit has one output channel suitable to switch a<br />

maximum load of 1150 VA, and a 1-10 V DC<br />

regulation output.<br />

LRC1505/00<br />

Scenio extension module to be linked to the light<br />

controller LRC1555 via a communication bus line. It<br />

has two modular sockets, both intended for bus<br />

loop-through connections. Sensors (IR receivers,<br />

movement detectors) cannot be connected to this<br />

unit.The unit has one output channel suitable to<br />

switch a maximum load of 1150 VA, and a 1-10 V<br />

DC regulating output. A 20 cm busline<br />

interconnection cable is supplied with the unit.<br />

IRT8020/00<br />

Eight-preset hand-held transmitter, suitable for<br />

infrared control of Scenio applications. It has 4 keys<br />

for presets and one key for “all off”. Keys for<br />

individual control and preset programming are<br />

located under a hinged cover at the bottom of the<br />

transmitter. In “teach mode” the transmitter can be<br />

used as a commissioning tool for Scenio.The group<br />

address selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.<br />

LIGHTING CONTROLS 11.31


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.32<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.32 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

IRT8010/00 TRANSM IR POINT 0.06 51749000<br />

LRH8010/00 MOUNT IR POINT 0.03 51797100<br />

IRT8050/00 TRANSM IR 2KEY WALL 0.12 51707000<br />

IRT8030/00 TRANSM IR TRIOS 0.22 51763600<br />

~GENERAL~General purpose components<br />

IRT8010/00<br />

Hand-held two-key transmitter, for infrared control of<br />

various lighting control systems.This transmitter was<br />

developed for the Occuswitch “presence” and<br />

“absence”, but it can also be used with Trios and<br />

other systems.The Occuswitch-IR is only able to<br />

switch, but when the transmitter is used with the<br />

named systems it can also dim the lights (by pressing<br />

a button >0.5 sec).The group address selector switch<br />

is contained in the battery compartment.The unit is<br />

supplied with batteries. A wall holder is available.<br />

LRH8010/00<br />

Wall holder for the IRT8010 hand-held two-key<br />

transmitter.<br />

IRT8050/00<br />

Two-key infrared remote control transmitter for wall<br />

mounting and table-top use.The unit can be used in<br />

Trios applications.The actual function of the two<br />

large keys can be selected with a dip switch in the<br />

battery compartment. A dip switch is also used to<br />

select the group address.<br />

IRT8030/00<br />

Four-preset hand-held transmitter, suitable for<br />

infrared control of Trios applications. It has 4 keys for<br />

presets and one key for “all off”. Keys for individual<br />

control and preset programming are located under a<br />

hinged cover at the bottom of the transmitter. In<br />

“teach mode” the transmitter can be used as<br />

commissioning tool for Trios.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.33<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

IRT8040/00 TRANSM IR SYS 0.22 51765000<br />

IRT8080/00 TRANSM IR MULTI-FUNC 0.22 51767400<br />

IRT8055/00 TRANSM IR 2KEY WALL TEMP 0.12 51843500<br />

IRT8040/00<br />

Hand-held transmitter, suitable for infrared control of<br />

Helio applications combined with HVAC and<br />

Sunblind systems. It has keys for two lighting groups,<br />

blinds control and temperature control and a key for<br />

“all off/absence”. Keys for lighting presets and preset<br />

programming are located under a hinged cover at<br />

the bottom of the transmitter.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

wall holder and batteries.<br />

IRT8080/00<br />

Hand-held transmitter, suitable for infrared control of<br />

various lighting control systems, other building<br />

systems (sunblind, HVAC).The transmitter can easily<br />

be adapted to project specifications by selecting one<br />

of its 15 settings.This can be achieved without any<br />

tools, and even after installation.The group address<br />

selector switch is contained in the battery<br />

compartment.The unit is supplied complete with<br />

text plates for the various settings, wall holder and<br />

batteries.<br />

IRT8055/00<br />

Multi-purpose infrared remote control transmitter<br />

for wall mounting, suitable for the transmission of<br />

measured temperature values.The unit can be used<br />

in integrated control systems with Heating,<br />

Ventilation and Airconditioning (HVAC) in<br />

combination with Helio applications.The actual<br />

function of the two large keys can be selected with<br />

a switch in the battery compartment.The same<br />

switch is used to select the group address. Only<br />

available as project special.<br />

LIGHTING CONTROLS 11.33


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.34<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.34 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LRM8114/00 SENSOR MOV DET 0.07 51906700<br />

LRI8134/00 SENSOR MULTISENSOR 0.07 51904300<br />

LRM8115/00 SENSR MOV DET LONG 0.07 51722300<br />

LRM8116/00 SENSR MOV DET WIDE 0.07 51841100<br />

LRM8114/00<br />

Compact advanced movement detector that<br />

features variable delay-to-off via DIP switch and can<br />

be part shaded to limit coverage.The sensor is<br />

powered via the additional modular plug-in (RJ12)<br />

connector cable that attaches it to a lighting<br />

controller.The sensor is suitable for both recessed<br />

and surface mounting. Mounting height is between<br />

2.5 m and 3.5 m.<br />

LRI8134/00<br />

Compact multi-sensor combining advanced internal<br />

light sensor, movement detector and infra-red<br />

receiver.The unit features individual element<br />

selection, variable delay-to-off via DIP switch and<br />

auto-calibrating light sensor. Movement detector can<br />

be part shaded to limit coverage.The sensor is<br />

powered via the additional modular plug-in (RJ12)<br />

connector cable that attaches it to a lighting<br />

controller.The sensor is suitable for both recessed<br />

and surface mounting. Mounting height is between<br />

2.5 m and 3.5 m.<br />

LRM8115/00<br />

Wall-mounted passive infrared movement detector<br />

for energy saving solutions in indoor lighting<br />

applications (automatic light switching based on<br />

occupancy). It detects the slightest movement within<br />

a range 25 m long. Equipped with adjustable<br />

switchoff delay times up to 35 minutes. Electrical<br />

connections via an additional sensor cable with a<br />

modular socket (“snap-in”).The daylight override<br />

function prevents the lights being witched on, if<br />

enough daylight is available.<br />

LRM8116/00<br />

Wall-mounted passive infrared movement detector<br />

for energy saving solutions in indoor lighting<br />

applications (automatic light switching based on<br />

occupancy). It detects the slightest movement within<br />

an angle of 90º (maximum range 15 m by 15 m at a<br />

mounting height of 2.1 m). Equipped with adjustable<br />

switchoff delay times up to 35 minutes. Electrical<br />

connections via an additional sensor cable with a<br />

modular socket (“snap-in”).The daylight override<br />

function prevents the lights being switched on, if<br />

enough daylight is available.


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.35<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Product ID<br />

Dimensions in mm<br />

Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

IRR8125/00 SENSR IR NV 0.03 51716200<br />

LRD8000/00 DIMMER 1KVA MAGNETIC TX 0.40 51571700<br />

LRD8010/10 DIMMER 1KVA ELECTRONIC TX 0.53 51573100<br />

LCU8020/00 INTERF PUSHBUTTON 0.10 51656100<br />

IRR8125/00<br />

Infrared receiver for remote control of lighting<br />

systems and other building-related functions.The unit<br />

is especially intended for “invisible” mounting behind<br />

a false ceiling. Only a thin plastic optic protrudes<br />

from the ceiling. More infrared receivers can be<br />

connected in parallel to cover large or odd-shaped<br />

rooms. It is powered from the corresponding<br />

controller, not requiring an external power supply<br />

unit. Electrical connections with a fixed cable (1 m.)<br />

with modular plug. Mounting height 2.5 to 3 m.<br />

LRD8000/00<br />

Light regulator for incandescent lamps, high-voltage<br />

halogen lamps and low-voltage halogen lamps with<br />

conventional transformers.The minimum light output<br />

level can be adjusted between 1% and 10% of<br />

maximum light output level. A green “power on”<br />

LED indicates the power status of the unit. Max. load<br />

is 1000 VA.<br />

LRD8010/10<br />

Light regulator for incandescent lamps, high-voltage<br />

halogen lamps and low-voltage halogen lamps with<br />

electronic transformers.The minimum light output<br />

level can be selected between 1% and 10% of<br />

maximum light output level. A green “power on”<br />

LED indicates the power status of the unit. Max. load<br />

is 1000 VA.<br />

LCU8020/00<br />

Push-button interface. RC5 code generator with<br />

digital inputs for the connection of push-buttons.<br />

Intended for manual control of light controllers and<br />

for coupling to other systems such a building<br />

management systems.The unit is connected to the<br />

infrared remote control input of the controller.<br />

Combination with an IR receiver is possible. Codes<br />

generated, depend on the input terminals used,<br />

20 combinations are possible. Different sets of<br />

codes, for Helio/Trios and Scenio can be selected<br />

with a rotary switch.The unit is powered from the<br />

corresponding controller.<br />

LIGHTING CONTROLS 11.35


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.36<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

11.36 LIGHTING CONTROLS<br />

Dimensions in mm<br />

Product ID Weight<br />

European Order<br />

(kg)<br />

Code (EOC)<br />

LPS100/00 POTSW 1-10V DIM 0.14 55803900<br />

LPS100/01 POTSW 1-10V DIM 0.14 55806000<br />

LCC8024/00 CONN BLOCK RJ12 1M-3F 0.01 51599100<br />

LPS100/00<br />

Manual rotary potentiometer with microswitch for<br />

recessed mounting. In combination with one or<br />

more electronic HF lightregulating ballasts, electronic<br />

light regulators or Trios controllers, it serves to<br />

control the light level of fluorescent lamps, halogen<br />

lamps or incandescent lamps.<br />

LPS100/01<br />

Manual rotary potentiometer with microswitch for<br />

surface mounting. In combination with one or more<br />

electronic HF light-regulating ballasts, electronic light<br />

regulators or Trios controllers, it serves to control<br />

the light level of fluorescent lamps, halogen lamps or<br />

incandescent lamps.<br />

LCC8024/00<br />

Branching connector with three modular sockets<br />

and one modular plug for use when more sensors<br />

are to be connected to the same controller input<br />

socket. (Or extension cable socket).


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.37<br />

<strong>Lighting</strong> <strong>controls</strong> General purpose components<br />

Dimensions in mm<br />

Product ID Weight<br />

(kg)<br />

European Order<br />

Code (EOC)<br />

LCC8014/00 CABLE SENSR RJ12M-RJ12M 5M 0.12 51637000<br />

LCC8012/00 CABLE EXT RJ12M-RJ12F 5M 0.13 51595300<br />

LCC8013/00 CABLE EXT RJ12M-RJ12F 20M 0.50 51597700<br />

LCC8011/00 CABLE INTER RJ12M-RJ12M 1M 0.03 51593900<br />

LCC8015/00 CABLE IR RJ12M-RJ12M 5M 0.12 51711700<br />

LCC8016/00 CABLE RJ12-END 3M 0.06 53920100<br />

LCC8016/10 CABLE RJ12-BL4 3M 0.06 53922500<br />

LCC8014/00<br />

Cable of 5 m length with modular plugs at both<br />

ends for the connection of sensors to the various<br />

types of light controllers.<br />

LCC8012/00/LCC8013/00<br />

Extension cables of 5 m length (LCC8012) and<br />

20 m length (LCC8013) with modular plugs and<br />

sockets to increase the distance between sensors<br />

(infrared receivers, light sensors and movement<br />

detectors) and the corresponding controllers.<br />

Product ID A<br />

LCC8012/00 5000<br />

LCC8013/00 20000<br />

LCC8011/00<br />

Interlink cable of 1 m length with modular plugs at<br />

both ends for interconnection of multifunctional light<br />

controllers so that the connected sensors can be<br />

shared by more controllers.<br />

LCC8015/00<br />

Interlink cable of 5 m length with modular plugs on<br />

both ends for interconnection of Trios light<br />

controllers.The cable is intended to distribute (only)<br />

the RC5 signal from a push-button interface over<br />

the connected controllers, especially in centrally<br />

controlled Trios applications.<br />

LCC8016/00<br />

LCC8016/10<br />

Sensor link cable of 3 m length with RJ12 connector<br />

on one end. Intended to connect general purpose<br />

sensors (excl. IRR8125) to LightMaster systems.<br />

The /00 is free end and /10 has a BL4 connector.<br />

LIGHTING CONTROLS 11.37


PHL-H11_INT.QXD 16-07-2004 10:45 Pagina 11.38<br />

<strong>Lighting</strong> <strong>controls</strong><br />

11.38 LIGHTING CONTROLS

Hooray! Your file is uploaded and ready to be published.