09.08.2013 Views

Instrumentation Cable RE-2Y(St) - Draka Communications ...

Instrumentation Cable RE-2Y(St) - Draka Communications ...

Instrumentation Cable RE-2Y(St) - Draka Communications ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Instrumentation</strong> <strong>Cable</strong><br />

<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />

BS 5308 type<br />

PE-insulated instrumentation cable, pairs, overall shielded,<br />

PVC or halogen free outer sheath<br />

According to EN 50288-7; based on BS 5308: Part 1: table 2:<br />

1986<br />

Application<br />

LINKING THE FUTU<strong>RE</strong><br />

www.prysmiangroup.com<br />

© 2008<br />

Changes reserved<br />

according<br />

to technical progress<br />

Used as instrumentation cables, especially for petrochemical industry, not suitable for outdoor laying. Optional available<br />

with light blue outer sheath for intrinsically safe use in explosive areas.<br />

Colour Coding<br />

Pair no. 1 2 3 4 5 6 7 8 9 10 11 12 13<br />

a-wire black black blue black blue green black blue green brow<br />

b-wire blue green green brow<br />

Pair no. 14 15<br />

a-wire brow<br />

n<br />

white<br />

b-wire red red<br />

n<br />

brow<br />

n<br />

Principle drawing<br />

<strong>Instrumentation</strong> <strong>Cable</strong><br />

<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y<br />

15x2x0.8<br />

brow<br />

n<br />

n<br />

black blue green<br />

white white white white red red red<br />

2008_49e<br />

Version 1 | 04.11.2008<br />

Page 1 of 3


<strong>Instrumentation</strong> <strong>Cable</strong><br />

<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />

BS 5308 type<br />

Construction<br />

<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y<br />

Conductor copper, solid, 0.8 mm = 0.5 sqmm soft annealed<br />

Insulation PE (<strong>2Y</strong>), colours see colour coding above<br />

Twisting cores twisted to pairs (SZ-stranding), n pairs twisted to group (SZ-stranding), groups twisted to<br />

<strong>Cable</strong> core wrapping at least one plastic tape<br />

LINKING THE FUTU<strong>RE</strong><br />

cable core (SZ-stranding), see table additional properties for grouping details<br />

Drain wire copper, tinned, 0.8 mm = 0.5 sqmm, soft annealed<br />

Shielding Al-PETP foil, metal side facing inward, with overlap, longitudinally applied, fixed with two helixes<br />

Outer sheath PVC (Y) or halogen free material (H), black (optional light blue for intrinsically safe),<br />

with inkjet marking: DRAKA EN 50288-7 m<br />

Mechanical and Thermal Properties<br />

Temperature range during operation - 30°C to + 60°C<br />

during installation - 5°C to + 60°C<br />

Electrical Properties at 20°C ± 5°C<br />

Conductor diameter mm 0.8<br />

Conductor resistance at 20°C Ω/km ≤ 36.8<br />

Insulation resistance GΩxkm ≥ 5<br />

Mutual capacitance at 1 kHz pF/m ≤ 115<br />

Capacitance unbalance at 1 kHz pair-to-<br />

pair<br />

AC test voltage for 1 minute<br />

pF/250 m<br />

≤ 250<br />

conductor/conductor V 1000<br />

conductor/screen V 1000<br />

www.prysmiangroup.com<br />

2008_49e<br />

Version 1 | 04.11.2008<br />

Page 2 of 3


<strong>Instrumentation</strong> <strong>Cable</strong><br />

<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />

BS 5308 type<br />

Additional Properties<br />

Dimensi<br />

on<br />

Outer<br />

diameter<br />

nominal<br />

<strong>Cable</strong><br />

weight<br />

net<br />

LINKING THE FUTU<strong>RE</strong><br />

<strong>St</strong>andar<br />

d<br />

supply<br />

length<br />

Drum<br />

size<br />

flange-Ø<br />

Transport<br />

weight<br />

gross<br />

www.prysmiangroup.com<br />

Copper<br />

content<br />

mm kg/km m mm kg/drum kg/km<br />

Grouping of pairs<br />

<strong>Instrumentation</strong> <strong>Cable</strong> n x 2 x 0.8 mm<br />

1 x 5.0 40 1000 400 45 15 (1pr)<br />

2 x<br />

(quad)<br />

5.5 50 1000 500 55 25<br />

(1quad)<br />

4 x 8.0 80 1000 600 90 45 (4pr)<br />

8 x 10.5 150 1000 700 160 86 (4pr) (4pr)<br />

10 x 12.0 180 1000 1000 230 106 (10pr)<br />

12 x 12.5 210 1000 1000 260 126 (4pr) (4pr) (4pr)<br />

15 x 14.0 250 1000 1000 320 156 (5pr) (10pr)<br />

16 x 14.5 260 1000 1000 330 166 (4pr) (4pr) (4pr) (4pr)<br />

20 x 16.0 320 1000 1200 470 206 (10pr) (10pr)<br />

24 x 17.5 380 1000 1200 530 246 (4pr) (4pr) (4pr) (4pr) (4pr)<br />

(4pr)<br />

[PRODUCT CODE TABLE]<br />

© PRYSMIAN GROUP 2008, All Rights Reserved<br />

All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any<br />

modification or alteration afterwards of product may give different result.<br />

The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without<br />

the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to<br />

amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.<br />

2008_49e<br />

Version 1 | 04.11.2008<br />

Page 3 of 3