<strong>Instrumentation</strong> <strong>Cable</strong><br />
<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />
BS 5308 type<br />
PE-insulated instrumentation cable, pairs, overall shielded,<br />
PVC or halogen free outer sheath<br />
According to EN 50288-7; based on BS 5308: Part 1: table 2:<br />
1986<br />
Application<br />
LINKING THE FUTU<strong>RE</strong><br />
www.prysmiangroup.com<br />
© 2008<br />
Changes reserved<br />
according<br />
to technical progress<br />
Used as instrumentation cables, especially for petrochemical industry, not suitable for outdoor laying. Optional available<br />
with light blue outer sheath for intrinsically safe use in explosive areas.<br />
Colour Coding<br />
Pair no. 1 2 3 4 5 6 7 8 9 10 11 12 13<br />
a-wire black black blue black blue green black blue green brow<br />
b-wire blue green green brow<br />
Pair no. 14 15<br />
a-wire brow<br />
n<br />
white<br />
b-wire red red<br />
n<br />
brow<br />
n<br />
Principle drawing<br />
<strong>Instrumentation</strong> <strong>Cable</strong><br />
<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y<br />
15x2x0.8<br />
brow<br />
n<br />
n<br />
black blue green<br />
white white white white red red red<br />
2008_49e<br />
Version 1 | 04.11.2008<br />
Page 1 of 3
<strong>Instrumentation</strong> <strong>Cable</strong><br />
<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />
BS 5308 type<br />
Construction<br />
<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y<br />
Conductor copper, solid, 0.8 mm = 0.5 sqmm soft annealed<br />
Insulation PE (<strong>2Y</strong>), colours see colour coding above<br />
Twisting cores twisted to pairs (SZ-stranding), n pairs twisted to group (SZ-stranding), groups twisted to<br />
<strong>Cable</strong> core wrapping at least one plastic tape<br />
LINKING THE FUTU<strong>RE</strong><br />
cable core (SZ-stranding), see table additional properties for grouping details<br />
Drain wire copper, tinned, 0.8 mm = 0.5 sqmm, soft annealed<br />
Shielding Al-PETP foil, metal side facing inward, with overlap, longitudinally applied, fixed with two helixes<br />
Outer sheath PVC (Y) or halogen free material (H), black (optional light blue for intrinsically safe),<br />
with inkjet marking: DRAKA EN 50288-7 m<br />
Mechanical and Thermal Properties<br />
Temperature range during operation - 30°C to + 60°C<br />
during installation - 5°C to + 60°C<br />
Electrical Properties at 20°C ± 5°C<br />
Conductor diameter mm 0.8<br />
Conductor resistance at 20°C Ω/km ≤ 36.8<br />
Insulation resistance GΩxkm ≥ 5<br />
Mutual capacitance at 1 kHz pF/m ≤ 115<br />
Capacitance unbalance at 1 kHz pair-to-<br />
pair<br />
AC test voltage for 1 minute<br />
pF/250 m<br />
≤ 250<br />
conductor/conductor V 1000<br />
conductor/screen V 1000<br />
www.prysmiangroup.com<br />
2008_49e<br />
Version 1 | 04.11.2008<br />
Page 2 of 3
<strong>Instrumentation</strong> <strong>Cable</strong><br />
<strong>RE</strong>-<strong>2Y</strong>(<strong>St</strong>)Y/H nx2x0.8<br />
BS 5308 type<br />
Additional Properties<br />
Dimensi<br />
on<br />
Outer<br />
diameter<br />
nominal<br />
<strong>Cable</strong><br />
weight<br />
net<br />
LINKING THE FUTU<strong>RE</strong><br />
<strong>St</strong>andar<br />
d<br />
supply<br />
length<br />
Drum<br />
size<br />
flange-Ø<br />
Transport<br />
weight<br />
gross<br />
www.prysmiangroup.com<br />
Copper<br />
content<br />
mm kg/km m mm kg/drum kg/km<br />
Grouping of pairs<br />
<strong>Instrumentation</strong> <strong>Cable</strong> n x 2 x 0.8 mm<br />
1 x 5.0 40 1000 400 45 15 (1pr)<br />
2 x<br />
(quad)<br />
5.5 50 1000 500 55 25<br />
(1quad)<br />
4 x 8.0 80 1000 600 90 45 (4pr)<br />
8 x 10.5 150 1000 700 160 86 (4pr) (4pr)<br />
10 x 12.0 180 1000 1000 230 106 (10pr)<br />
12 x 12.5 210 1000 1000 260 126 (4pr) (4pr) (4pr)<br />
15 x 14.0 250 1000 1000 320 156 (5pr) (10pr)<br />
16 x 14.5 260 1000 1000 330 166 (4pr) (4pr) (4pr) (4pr)<br />
20 x 16.0 320 1000 1200 470 206 (10pr) (10pr)<br />
24 x 17.5 380 1000 1200 530 246 (4pr) (4pr) (4pr) (4pr) (4pr)<br />
(4pr)<br />
[PRODUCT CODE TABLE]<br />
© PRYSMIAN GROUP 2008, All Rights Reserved<br />
All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any<br />
modification or alteration afterwards of product may give different result.<br />
The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without<br />
the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to<br />
amend this specification without prior notice. This specification is not contractually valid unless specifically authorised by Prysmian Group.<br />
2008_49e<br />
Version 1 | 04.11.2008<br />
Page 3 of 3