5.<br />
6.<br />
8<br />
Connect the left and right power cables from transformer to<br />
the studs in the rear side of electronic module. Connectors<br />
have a tactile mechanical locking. Connect the AC power cable<br />
to the rear side (bottom left) of electronic module.<br />
Note: avoid that cables touch the transformers.<br />
Connect the AC cables from grid to AC connector located at<br />
bottom-right side of transformer module.<br />
Put the left and right covers of transformer module. Connect<br />
the earth cables and fix the covers to transformer module by<br />
using the 2 supplied screws (it is only shown the left side - repeat<br />
the process for left side).<br />
fig. 5.<br />
Process of physical installation.<br />
4.3. cONNEctION.<br />
Wiring methods must be in accordance with local regulations.<br />
Appendix A includes a detailed electrical diagram for a typical<br />
EqUINOX <strong>LV</strong> system.<br />
photovoltaic modules (pV) have to be disconnected<br />
from wires that link the panel with the inverter before<br />
the installation. risk of electrocution.<br />
4.3.1. Of dc input.<br />
The following procedure describes the steps to connect the inverter<br />
to the photovoltaic panels.<br />
attention: a wrong connection can both damage<br />
the equipment and make injuries to the personnel.<br />
do no exceed the stated maximum dc voltage.<br />
1.<br />
2.<br />
3.<br />
4.<br />
5.<br />
6.<br />
7.<br />
Check that power supply cables from photovoltaic panels are<br />
disconnected or not alive.<br />
do not disconnect the cables from photovoltaic<br />
panels, risk of electrocution exists.<br />
Address the DC cables from panels to DC input cable glands of<br />
combinator module.<br />
Connect the negative cable to “PV Array Negative” terminal<br />
strip.<br />
Connect the positive cable to “PV Array Positive” terminal<br />
strip.<br />
Connect the photovoltaic panels to the wires of combinator<br />
module.<br />
Check the open circuit voltage of each circuit (positive cable<br />
of each circuit has to be isolated from DC bus) with a digital<br />
voltmeter. Check the voltage between each positive cable and<br />
negative of terminal strip first. Voltage can be a little bit different<br />
from the expected open circuit votlage due to the temperature<br />
of the module and/or the sunlight. Nevertheless, if<br />
panels are properly wired, each circuit should be at a few volts<br />
from the other ones.<br />
Leave DC switches in OFF position.<br />
4.3.2. Of ac output.<br />
The following procedure describes the steps to connect the inverter<br />
to the protection switchgear panel (interconnection point).<br />
1.<br />
2.<br />
3.<br />
attention: a wrong connection of the panel wiring<br />
can damage the unit and make personal injuries.<br />
Remove the panel of AC wiring.<br />
Connect the AC cable.<br />
Address cables to L1 and L2. Connect the earth cable to GND<br />
terminal.<br />
4.4. UNINStaLLatION.<br />
an error when disconnecting the cables of photovoltaic<br />
panels can cause risk of electrocution.<br />