<strong>Sterlite</strong> Power<br />
Cable Solutions
<strong>Sterlite</strong> Medium Voltage (MV) XLPE-insulated Power Cables<br />
Product Applications<br />
<strong>Sterlite</strong>(R) Medium Voltage (MV) power cables are crosslinked polyethylene (XLPE-insulated) cables that possess very good<br />
electrical, mechanical and thermal characteristics in medium voltage networks. This type of insulation offers excellent chemical<br />
resistant, is non-hygroscopic and is resistant to cold.<br />
Product Applications<br />
Crosslinked polyethylene (XLPE) has become the globally preferred insulation for power cables, both for distribution and<br />
transmission system applications.<br />
Product Benefits<br />
Higher current carrying capacity due to higher permissible continuous conductor temperature<br />
0<br />
Higher Short Circuit rating as it can withstand short circuit temperature up to 250 C<br />
0<br />
Higher temperature to withstand emergency overload up to 130 C<br />
Extremely low dielectric losses<br />
Light-weight<br />
Easier to join and terminate<br />
Smaller bending radius<br />
0<br />
Flexible up to -40 C<br />
Not prone to fatigue damage due to vibration or loading cycles<br />
Typical Product Specifications<br />
Conductor: Electrolytic grade Copper or Aluminum, round, multi-wire stranded, circular and compact in various sizes according to<br />
IS 8130/ IEC 60228.<br />
Conductor Shield: Conductors for cables rated over 3.3 KV are shielded by extruded semi conducting compound which is of<br />
bonded type.<br />
Insulation: Natural, chemically cross linked polyethylene. Thickness is according to relevant IS or IEC standards.<br />
Insulation Shield: Cables rated over 3.3 KV have a non-metallic semi conducting part in combination with a metallic part applied<br />
over the insulation. Non-metallic part is generally made of extruded semi conducting compound and is applied together with<br />
conductor shield. Insulation in one process (wherever required semi conducting tape/ water swellable tape is provided) can be<br />
applied directly over non-metallic insulation screen followed by helically applied bare annealed plain copper tape applied with an<br />
overlap.<br />
Core Identification: It can be provided by coloured strips applied on core or by printed numerals (1, 2&3) or printed strips.<br />
Laying–Up: For multi core cables, the cores are cabled with fillers in the interstices.<br />
Inner Sheath (Common Covering): The laid up cores are provided with a common covering either of tape or extrusion of thickness<br />
as per relevant standard.<br />
Armour: The armour can either be applied directly over core or inner sheath of single core cables and over inner sheath for multi<br />
core cables. Aluminium wire or strip constitutes the armour for single core cables where as GI wire or strip constitutes the armour<br />
for multi core cables.<br />
Outer Sheath: All cables are provided with an extruded inner sheath whose thickness is governed by relevant standard. The PVC of<br />
outer sheath conforms to type ST 2 of IS 5831, wherever required “FR”, “FRLS” or “LSOH” can be provided. The colour of outer<br />
sheath is generally black.<br />
Issued: June 2012 1
Manufacturing Process<br />
To ensure the accuracy and precision of the manufacturing process, <strong>Sterlite</strong> has a state of-the-art plant with top of the line<br />
machines enabling control of critical process and quality parameters. All <strong>Sterlite</strong> production lines are backed up with strong quality<br />
assurance systems. This is done by ensuring that all process and test equipments are periodically calibrated with defined<br />
benchmarks.<br />
Quality Tests<br />
The following tests are performed randomly to ensure a better quality:<br />
Degree of Cross linking for the Dielectric Void and contamination test involving microscopic inspection of imperfections of<br />
the insulation<br />
Bonding test of insulation screen with the insulation<br />
Online Diameter and eccentricity measurement and control by X-Ray unit, to ensure consistency and accuracy of Insulated<br />
core.<br />
Further, all Cables produced are subjected to the following routine tests as per IS 7098 (Part-2):1985:<br />
High Voltage test<br />
Conductor Resistance test<br />
Partial Discharge test<br />
Tests on conductors<br />
Tests on Armour<br />
Test for dimensions of insulation and sheath<br />
Physical tests for insulation<br />
Physical tests for outer sheath<br />
Partial Discharge<br />
Bending test followed by partial discharge<br />
Dielectric Power Factor test as a function of voltage<br />
Dielectric Power Factor test as a function of Temperature<br />
Insulation Resistance (Volume Resistivity test)<br />
Heating cycle test<br />
Impulse withstand test<br />
High Voltage test (4 hours)<br />
Flammability<br />
Issued: June 2012 2
For FR, FRLS cables , in addition to tests mentioned above, following additional tests are done<br />
Test Function Specification Specified Value<br />
Applicable For<br />
Critical Oxygen index To determine the<br />
percentage of oxygen<br />
required for supporting<br />
combustion of sheathing<br />
material at room temperature<br />
ASTM- D- 2863 Min 29<br />
FR and FRLS<br />
Temperature Index To determine at what<br />
temperature 21 % of Oxygen<br />
will support combustion of<br />
sheathing material<br />
ASTM- D- 2863 Min 250° C<br />
FR FR and FRLS<br />
Smoke Density<br />
To determine visibility (light<br />
transmission) under fire of<br />
sheath material<br />
ASTM- D- 2843 Max 60%<br />
FRLS<br />
Acid Gas generation To measure the amount of<br />
Hydrochloric gas evolved<br />
IEC- 754- I<br />
Max 20% by weight<br />
FRLS<br />
Flammability test<br />
from PVC sheath under<br />
construction<br />
1. To determine ignition 1. Swedish<br />
1. Min 300 mm<br />
FRLS<br />
on group of cables resistance and flame<br />
standard SS unburnt portion from<br />
propagation under specified 4241475<br />
top of 850 mm<br />
conditions<br />
class F3<br />
2. To determine ignition 2. IEC 332- I 2. min unburnt portion FR and FRLS<br />
Flammability<br />
test on group<br />
of cables<br />
Longer Packing Lengths<br />
resistance and flame<br />
propagation under specified<br />
conditions<br />
3. To determine ignition<br />
resistance and flame<br />
propagation especially for a<br />
bunch of cable under<br />
specified conditions<br />
To determine flame<br />
propagation in cable in<br />
installed conditions<br />
3. IEC 332- 3<br />
50 mm from the top of<br />
600+ 25 mm sample after<br />
specified duration<br />
3. min 2.5m unburnt<br />
above burner after<br />
specified duration in<br />
3.5 m sample<br />
FR and FRLS<br />
IEEE- 383 In total burning of 20<br />
minutes at 1500 F of 8 m<br />
cable samples, burning<br />
shall not go the top<br />
FR and FRLS<br />
Larger Take up capacities in <strong>Sterlite</strong> make it possible to give longer delivery lengths than those mentioned in the catalogue to minimize number of joints<br />
which are a major cause in failures.<br />
The dimensional details, weights and packing are mentioned in Tables 1 to 10.<br />
Issued: June 2012 3
Operating Conditions:<br />
Electrical Parameters of the cables mentioned in Tables 11 to 19 are based on the following operating conditions<br />
0<br />
Maximum permissible conductor : 90 C<br />
temperature for continuous operation<br />
0<br />
Ambient Air Temperature : 40 C<br />
0<br />
Ground Temperature : 30 C<br />
0<br />
Thermal Resistivity of Soil : 150 C cm/watt<br />
Depth of Laying : 90 cms for cables up to 11 KV<br />
: 105 cms for cables above 11 KV<br />
Three single core cables are laid in trefoil formation with screen/Armour bonded at both ends<br />
Multi core cables are laid singly<br />
Rating Factors:<br />
For installations other than standard conditions mentioned above, rating factors have to be applied and have been given in Tables 20 to 25.<br />
Issued: June 2012<br />
4
DIMENSION AND WEIGHT (Tables)<br />
Table 01<br />
Single-core 3.8/6.6 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semiconducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed<br />
3.8/6.6 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
3.0<br />
3.3<br />
3.5<br />
3.5<br />
3.6<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.3<br />
0.3<br />
0.3<br />
0.3<br />
0.3<br />
0.3<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.5<br />
Table 02<br />
Three-core 3.8/6.6 KV<br />
strip Armoured cables with Aluminium conductors<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
2.8<br />
3.0<br />
3.3<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
0.6<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
Nominal<br />
Dimension of<br />
armour<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.4<br />
1.4<br />
1.4<br />
1.4<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.72<br />
1.88<br />
2.04<br />
2.20<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.56<br />
1.72<br />
1.72<br />
1.88<br />
1.88<br />
2.04<br />
2.2<br />
2.2<br />
2.36<br />
2.52<br />
2.84<br />
Approx<br />
overall<br />
dia<br />
mm<br />
24.5<br />
26.0<br />
28.0<br />
29.0<br />
31.0<br />
35.5<br />
35.5<br />
37.7<br />
42.0<br />
49.0<br />
54.0<br />
59.0<br />
Approx<br />
overall<br />
dia<br />
mm<br />
36.0<br />
39.0<br />
42.0<br />
45.5<br />
49.5<br />
53.0<br />
56.5<br />
60.0<br />
65.5<br />
70.2<br />
79.5<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
760<br />
870<br />
1000<br />
1130<br />
1130<br />
1450<br />
1770<br />
2030<br />
2500<br />
3480<br />
4340<br />
5180<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1650<br />
1900<br />
2190<br />
2610<br />
3040<br />
3510<br />
4000<br />
4575<br />
5465<br />
6390<br />
7950<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Three Core Aluminium Conductor Extruded Semiconducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed<br />
3.8/6.6 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Issued: June 2012<br />
5
DIMENSION AND WEIGHT (Tables)<br />
Table 03<br />
Single-core 6.6/6.6 KV and 6.35/11 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semiconducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed<br />
6.35/11 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
3.6<br />
Minimum<br />
Thickness of<br />
iinner sheath<br />
mm<br />
0.3<br />
0.3<br />
0.3<br />
0.3<br />
0.3<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.6<br />
Table 04<br />
Three-core 6.6/6.6 KV or 6.35/11 KV<br />
strip Armoured cables with Aluminium conductors<br />
Three Core Aluminium Conductor Extruded Semiconducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed<br />
6.35/11 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.4<br />
0.5<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
0.6<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
1.6<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
Nominal<br />
Dimension<br />
outer sheath<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.4<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.72<br />
1.88<br />
2.04<br />
2.20<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.72<br />
1.72<br />
1.88<br />
1.88<br />
2.04<br />
2.20<br />
2.20<br />
2.36<br />
2.52<br />
2.68<br />
2.84<br />
Approx<br />
overall<br />
dia<br />
mm<br />
26.0<br />
27.5<br />
29.5<br />
31.0<br />
32.5<br />
35.0<br />
37.3<br />
39.0<br />
42.5<br />
49.5<br />
54.5<br />
59.0<br />
App<br />
overall<br />
diameter<br />
mm<br />
40.0<br />
42.5<br />
45.5<br />
49.0<br />
53.0<br />
56.5<br />
60.0<br />
64.0<br />
69.0<br />
73.5<br />
80.5<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
840<br />
960<br />
1100<br />
1250<br />
1380<br />
1630<br />
1880<br />
2110<br />
2570<br />
3500<br />
4370<br />
5200<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1940<br />
2175<br />
2500<br />
2900<br />
3450<br />
3900<br />
4370<br />
5030<br />
5920<br />
6780<br />
8120<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Standard<br />
packing length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
350<br />
300<br />
Issued: June 2012<br />
6
DIMENSION AND WEIGHT (Tables)<br />
Table 05<br />
Single-core 11/11 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed 11/11<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.3<br />
0.3<br />
0.3<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
Table 06<br />
Three-core 11/11 KV<br />
strip Armoured cables with Aluminium conductors<br />
Three Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed 11/11<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.5<br />
0.6<br />
0.6<br />
0.6<br />
0.6<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
1.6<br />
1.6<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
2.5<br />
Nominal<br />
Dimension<br />
of Armour<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.72<br />
1.72<br />
1.88<br />
2.04<br />
2.20<br />
2.36<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.88<br />
2.04<br />
2.20<br />
2.20<br />
2.36<br />
2.36<br />
2.52<br />
2.68<br />
2.84<br />
3.00<br />
3.00<br />
Approx<br />
overall<br />
dia<br />
mm<br />
30.2<br />
31.7<br />
34.2<br />
35.5<br />
37.0<br />
38.8<br />
41.5<br />
43.0<br />
46.5<br />
54.5<br />
58.7<br />
63.0<br />
App<br />
overall<br />
diameter<br />
mm<br />
48.5<br />
51.5<br />
54.5<br />
58.0<br />
62.0<br />
65.5<br />
69.0<br />
73.0<br />
78.0<br />
82.0<br />
89.0<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1070<br />
1200<br />
1420<br />
1550<br />
1700<br />
1840<br />
2200<br />
2420<br />
2880<br />
4030<br />
4800<br />
5600<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
2670<br />
3010<br />
3360<br />
3800<br />
4390<br />
4880<br />
5430<br />
6120<br />
7080<br />
7970<br />
9360<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
400<br />
350<br />
250<br />
200<br />
Issued: June 2012<br />
7
DIMENSION AND WEIGHT (Tables)<br />
Table 07<br />
Single-core 12.7/22 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed<br />
12.7/22 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
6.0<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.3<br />
0.3<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
Table 08<br />
Three-core 12.7/22 KV<br />
strip Armoured cables with Aluminium conductors<br />
Three Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed<br />
12.7/22 KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.5<br />
0.6<br />
0.6<br />
0.6<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
1.6<br />
1.6<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
2.5<br />
Nominal<br />
Dimension<br />
of Armour<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.72<br />
1.72<br />
1.72<br />
1.88<br />
2.04<br />
2.20<br />
2.36<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
2.04<br />
2.04<br />
2.20<br />
2.36<br />
2.36<br />
2.52<br />
2.68<br />
2.68<br />
2.84<br />
3.0<br />
3.0<br />
Approx<br />
overall<br />
dia<br />
mm<br />
31.2<br />
32.6<br />
35.2<br />
36.6<br />
38.0<br />
40.2<br />
42.4<br />
44.0<br />
47.7<br />
55.6<br />
59.7<br />
64.0<br />
App<br />
overall<br />
diameter<br />
mm<br />
51.0<br />
53.5<br />
57.0<br />
60.5<br />
64.5<br />
68.0<br />
71.5<br />
75.0<br />
80.0<br />
84.0<br />
91.0<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1140<br />
1280<br />
1500<br />
1650<br />
1800<br />
2030<br />
2300<br />
2550<br />
3000<br />
4160<br />
4970<br />
5800<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
2900<br />
3200<br />
3590<br />
4100<br />
4650<br />
5175<br />
5750<br />
6380<br />
7360<br />
8280<br />
9670<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
400<br />
350<br />
300<br />
250<br />
200<br />
Issued: June 2012<br />
8
DIMENSION AND WEIGHT (Tables)<br />
Table 09<br />
Single-core 19/33 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed 19/33<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
8.8<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
0.7<br />
Table 10<br />
Three-core 19/33 KV<br />
strip Armoured cables with Aluminium conductors<br />
Three Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed 19/33<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
2.5<br />
2.5<br />
3.15<br />
Nominal<br />
Dimension<br />
of Armour<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.56<br />
1.56<br />
1.72<br />
1.72<br />
1.72<br />
1.88<br />
1.88<br />
2.04<br />
2.04<br />
2.36<br />
2.36<br />
2.52<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
2.52<br />
2.68<br />
2.84<br />
2.84<br />
3.00<br />
3.00<br />
3.00<br />
3.00<br />
3.00<br />
Approx<br />
overall<br />
dia<br />
mm<br />
36.5<br />
38.2<br />
40.2<br />
41.6<br />
43.0<br />
45.1<br />
47.3<br />
50.4<br />
53.7<br />
61.2<br />
64.6<br />
70.5<br />
App<br />
overall<br />
diameter<br />
mm<br />
69.5<br />
73.5<br />
77.5<br />
80.5<br />
84.0<br />
88.0<br />
92.5<br />
96.5<br />
103.0<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1470<br />
1600<br />
1800<br />
1960<br />
2100<br />
2340<br />
2630<br />
3070<br />
3500<br />
4700<br />
5410<br />
6560<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
5050<br />
5660<br />
6310<br />
6840<br />
7480<br />
8190<br />
9190<br />
10080<br />
11600<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
400<br />
350<br />
300<br />
250<br />
200<br />
Issued: June 2012<br />
9
ELECTRICAL PARAMETERS (Tables)<br />
Table 11<br />
PERMISSIBLE MAXIMUM SHORT CIRCUIT RATINGS FOR XLPE CABLES<br />
Conductor Area<br />
Sq.mm<br />
16<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
Short circuit rating for 1 second duration<br />
Copper Conductor Aluminium Conductor<br />
KA<br />
2.28<br />
3.57<br />
5.0<br />
7.15<br />
10.0<br />
13.58<br />
17.16<br />
21.45<br />
26.45<br />
34.32<br />
42.9<br />
57.2<br />
71.5<br />
90.0<br />
114.28<br />
142.85<br />
KA<br />
1.51<br />
2.36<br />
3.30<br />
4.72<br />
6.60<br />
8.96<br />
11.32<br />
14.16<br />
17.46<br />
22.65<br />
28.32<br />
37.76<br />
47.20<br />
59.47<br />
75.52<br />
94.40<br />
For duration other than 1 second, short circuit may be calculated from the following formula : Isc = I/t<br />
Isc=Short circuit current during time t in Amperes<br />
I = Short circuit during time of 1 second, as given in above table<br />
t = Short circuit current duration in seconds<br />
Note: For large currents , the force between the conductors must be considered specially when single core cables are used<br />
Table 12<br />
CAPACITANCE<br />
Conductor Area<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
CAPACITANCE<br />
3.8/6.6 KV<br />
6.6/6.6 KV &<br />
6.35/11 KV<br />
11/11 KV<br />
µF/Km<br />
µF/Km<br />
µF/Km<br />
0.22<br />
0.18<br />
0.135<br />
0.24<br />
0.20<br />
0.148<br />
0.27<br />
0.22<br />
0.165<br />
0.31<br />
0.25<br />
0.184<br />
0.35<br />
0.28<br />
0.205<br />
0.38<br />
0.31<br />
0.222<br />
0.42<br />
0.34<br />
0.239<br />
0.46<br />
0.37<br />
0.260<br />
0.51<br />
0.41<br />
0.286<br />
0.51<br />
0.44<br />
0.306<br />
0.53<br />
0.49<br />
0.343<br />
0.56<br />
0.55<br />
0.380<br />
0.63<br />
0.61<br />
0.421<br />
0.69<br />
0.67<br />
0.462<br />
0.75<br />
0.75<br />
0.508<br />
12.7/22 KV<br />
µF/Km<br />
0.128<br />
0.139<br />
0.155<br />
0.173<br />
0.192<br />
0.208<br />
0.224<br />
0.243<br />
0.266<br />
0.285<br />
0.319<br />
0.353<br />
0.391<br />
0.428<br />
0.471<br />
19/33 KV<br />
µF/Km<br />
-<br />
-<br />
0.121<br />
0.134<br />
0.147<br />
0.158<br />
0.169<br />
0.182<br />
0.199<br />
0.211<br />
0.235<br />
0.258<br />
0.284<br />
0.310<br />
0.339<br />
Issued: June 2012<br />
10
ELECTRICAL PARAMETERS (Tables)<br />
Table 13<br />
CURRENT RATING<br />
Cable<br />
size<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
Cable<br />
size<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
Ground<br />
96<br />
115<br />
135<br />
165<br />
195<br />
225<br />
250<br />
285<br />
330<br />
370<br />
420<br />
480<br />
540<br />
610<br />
680<br />
Ground<br />
98<br />
115<br />
140<br />
170<br />
200<br />
225<br />
250<br />
285<br />
325<br />
365<br />
410<br />
465<br />
520<br />
560<br />
600<br />
3.3 kV (E) & (UE)<br />
Duct<br />
86<br />
100<br />
120<br />
145<br />
175<br />
200<br />
220<br />
250<br />
285<br />
325<br />
370<br />
420<br />
470<br />
530<br />
580<br />
Table 14<br />
CURRENT RATING<br />
3.3 kV (E) & (UE)<br />
Duct<br />
87<br />
105<br />
120<br />
150<br />
175<br />
200<br />
220<br />
250<br />
285<br />
320<br />
360<br />
400<br />
445<br />
485<br />
510<br />
Single core XLPE Insulated Unarmoured Cables laid in trefoil formation (Solid Bonded)<br />
Aluminium (Amp) Copper (Amp)<br />
Air<br />
105<br />
125<br />
150<br />
190<br />
235<br />
275<br />
310<br />
360<br />
425<br />
495<br />
580<br />
690<br />
800<br />
930<br />
1060<br />
Air<br />
110<br />
135<br />
160<br />
200<br />
245<br />
285<br />
325<br />
375<br />
440<br />
500<br />
590<br />
680<br />
780<br />
880<br />
970<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Ground<br />
97<br />
115<br />
135<br />
165<br />
200<br />
225<br />
250<br />
285<br />
330<br />
370<br />
425<br />
485<br />
550<br />
620<br />
690<br />
Ground<br />
99<br />
115<br />
140<br />
170<br />
200<br />
225<br />
250<br />
285<br />
325<br />
365<br />
410<br />
455<br />
510<br />
550<br />
590<br />
Duct<br />
86<br />
100<br />
120<br />
145<br />
175<br />
195<br />
220<br />
250<br />
285<br />
325<br />
375<br />
420<br />
475<br />
530<br />
590<br />
Duct<br />
87<br />
105<br />
120<br />
145<br />
175<br />
195<br />
220<br />
245<br />
280<br />
315<br />
355<br />
395<br />
435<br />
470<br />
500<br />
Air<br />
110<br />
135<br />
160<br />
200<br />
245<br />
285<br />
320<br />
370<br />
455<br />
510<br />
600<br />
700<br />
810<br />
940<br />
1070<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Air<br />
115<br />
140<br />
165<br />
210<br />
255<br />
295<br />
330<br />
380<br />
450<br />
510<br />
590<br />
680<br />
780<br />
870<br />
960<br />
22kV(E) & 33kV (E) 3.3kV<br />
Ground<br />
-<br />
115<br />
135<br />
165<br />
195<br />
225<br />
250<br />
280<br />
325<br />
370<br />
420<br />
480<br />
550<br />
610<br />
680<br />
Ground<br />
-<br />
115<br />
135<br />
165<br />
195<br />
225<br />
250<br />
280<br />
320<br />
355<br />
400<br />
445<br />
495<br />
540<br />
570<br />
Duct<br />
-<br />
100<br />
120<br />
145<br />
170<br />
195<br />
215<br />
245<br />
280<br />
320<br />
360<br />
410<br />
470<br />
520<br />
580<br />
Duct<br />
-<br />
100<br />
120<br />
145<br />
170<br />
195<br />
215<br />
240<br />
275<br />
305<br />
345<br />
380<br />
420<br />
460<br />
490<br />
Air<br />
-<br />
140<br />
170<br />
210<br />
255<br />
295<br />
330<br />
380<br />
450<br />
520<br />
610<br />
710<br />
820<br />
950<br />
1080<br />
Single core XLPE Insulated Armoured Cables laid in trefoil formation (Solid Bonded)<br />
Aluminium (Amp) Copper (Amp)<br />
22kV(E) & 33kV (E) 3.3kV<br />
Air<br />
-<br />
145<br />
170<br />
215<br />
260<br />
300<br />
340<br />
385<br />
450<br />
510<br />
600<br />
680<br />
770<br />
870<br />
950<br />
Ground<br />
125<br />
150<br />
175<br />
215<br />
255<br />
290<br />
320<br />
365<br />
420<br />
470<br />
530<br />
600<br />
670<br />
740<br />
800<br />
Ground<br />
125<br />
150<br />
175<br />
215<br />
255<br />
290<br />
325<br />
360<br />
415<br />
460<br />
510<br />
560<br />
610<br />
660<br />
680<br />
Duct<br />
110<br />
130<br />
155<br />
190<br />
225<br />
255<br />
285<br />
320<br />
370<br />
410<br />
465<br />
520<br />
580<br />
640<br />
690<br />
Duct<br />
115<br />
135<br />
155<br />
190<br />
225<br />
255<br />
285<br />
315<br />
360<br />
400<br />
445<br />
485<br />
530<br />
570<br />
580<br />
Air<br />
130<br />
160<br />
195<br />
245<br />
300<br />
350<br />
400<br />
460<br />
550<br />
630<br />
740<br />
860<br />
980<br />
1120<br />
1250<br />
Air<br />
140<br />
170<br />
205<br />
260<br />
315<br />
365<br />
415<br />
475<br />
560<br />
640<br />
730<br />
840<br />
940<br />
1040<br />
1100<br />
Ground<br />
125<br />
150<br />
175<br />
215<br />
255<br />
290<br />
325<br />
365<br />
420<br />
475<br />
540<br />
610<br />
680<br />
750<br />
820<br />
Ground<br />
125<br />
150<br />
175<br />
215<br />
255<br />
290<br />
320<br />
360<br />
410<br />
455<br />
510<br />
550<br />
600<br />
640<br />
670<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Duct<br />
110<br />
130<br />
155<br />
190<br />
225<br />
255<br />
285<br />
320<br />
370<br />
415<br />
465<br />
520<br />
590<br />
640<br />
700<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Duct<br />
110<br />
130<br />
155<br />
190<br />
225<br />
250<br />
280<br />
315<br />
355<br />
395<br />
435<br />
475<br />
520<br />
540<br />
570<br />
Air<br />
140<br />
175<br />
205<br />
260<br />
315<br />
365<br />
415<br />
480<br />
560<br />
650<br />
760<br />
880<br />
1010<br />
1140<br />
700<br />
Air<br />
150<br />
180<br />
215<br />
270<br />
325<br />
375<br />
425<br />
485<br />
570<br />
640<br />
730<br />
830<br />
930<br />
1010<br />
1090<br />
22kV(E) & 33kV (E)<br />
Ground<br />
-<br />
150<br />
175<br />
210<br />
255<br />
290<br />
320<br />
360<br />
420<br />
470<br />
530<br />
600<br />
680<br />
750<br />
820<br />
22kV(E) & 33kV (E)<br />
Ground<br />
-<br />
150<br />
175<br />
215<br />
250<br />
285<br />
315<br />
355<br />
400<br />
445<br />
495<br />
540<br />
580<br />
630<br />
650<br />
Duct<br />
-<br />
130<br />
150<br />
185<br />
220<br />
250<br />
280<br />
315<br />
365<br />
410<br />
460<br />
520<br />
580<br />
640<br />
700<br />
Duct<br />
-<br />
130<br />
150<br />
185<br />
220<br />
245<br />
275<br />
305<br />
350<br />
380<br />
425<br />
460<br />
500<br />
530<br />
550<br />
Air<br />
-<br />
180<br />
215<br />
270<br />
330<br />
380<br />
430<br />
490<br />
580<br />
660<br />
770<br />
890<br />
1020<br />
1160<br />
1290<br />
Air<br />
-<br />
185<br />
220<br />
275<br />
335<br />
385<br />
430<br />
490<br />
570<br />
650<br />
740<br />
830<br />
920<br />
1020<br />
1080<br />
Issued: June 2012<br />
11
ELECTRICAL PARAMETERS (Tables)<br />
Table 15<br />
CURRENT RATING<br />
Cable<br />
size<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Table 16<br />
REACTANCE OF SINGLE CORE XLPE CABLES<br />
Cable<br />
size<br />
mm²<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
Ground<br />
94<br />
115<br />
135<br />
165<br />
195<br />
220<br />
245<br />
280<br />
320<br />
360<br />
410<br />
3.3 kV (E) & (UE)<br />
Duct<br />
80<br />
94<br />
110<br />
140<br />
165<br />
185<br />
210<br />
235<br />
270<br />
305<br />
350<br />
UNARM<br />
0.113<br />
0.105<br />
0.100<br />
0.097<br />
0.095<br />
0.091<br />
0.089<br />
0.088<br />
0.086<br />
0.085<br />
0.082<br />
0.081<br />
0.080<br />
Three core XLPE Insulated Armoured Cables<br />
Aluminium (Amp) Copper (Amp)<br />
Air<br />
99<br />
120<br />
145<br />
185<br />
225<br />
255<br />
295<br />
340<br />
400<br />
460<br />
535<br />
3.8/ 6.6 KV<br />
ARM<br />
/Km /Km<br />
0.128<br />
0.119<br />
0.114<br />
0.111<br />
0.108<br />
0.105<br />
0.101<br />
0.097<br />
0.094<br />
0.091<br />
0.089<br />
0.088<br />
0.087<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Ground<br />
95<br />
115<br />
130<br />
160<br />
190<br />
220<br />
245<br />
275<br />
315<br />
355<br />
400<br />
Duct<br />
82<br />
97<br />
115<br />
140<br />
165<br />
190<br />
210<br />
240<br />
275<br />
310<br />
350<br />
APP REACTANCE AT 50Hz assuming cables in trefoil touching<br />
UNARM<br />
0.117<br />
0.109<br />
0.104<br />
0.101<br />
0.098<br />
0.096<br />
0.092<br />
0.090<br />
0.087<br />
0.085<br />
0.082<br />
0.081<br />
0.080<br />
Air<br />
105<br />
125<br />
150<br />
190<br />
230<br />
260<br />
295<br />
335<br />
395<br />
450<br />
520<br />
6.6/ 6.6KV &<br />
6.35/ 11 KV<br />
ARM<br />
/Km /Km<br />
22kV(E) & 33kV (E) 3.3 kV (E) & (UE)<br />
Ground<br />
-<br />
110<br />
130<br />
160<br />
190<br />
215<br />
240<br />
270<br />
310<br />
350<br />
395<br />
0.128<br />
0.119<br />
0.114<br />
0.111<br />
0.107<br />
0.105<br />
0.101<br />
0.099<br />
0.095<br />
0.092<br />
0.089<br />
0.088<br />
0.087<br />
Duct<br />
-<br />
98<br />
115<br />
140<br />
170<br />
190<br />
215<br />
240<br />
275<br />
310<br />
355<br />
Air<br />
-<br />
130<br />
155<br />
190<br />
230<br />
265<br />
300<br />
340<br />
400<br />
455<br />
530<br />
UNARM<br />
11/ 11 KV<br />
ARM<br />
/Km /Km<br />
0.127<br />
0.118<br />
0.113<br />
0.110<br />
0.107<br />
0.103<br />
0.099<br />
0.097<br />
0.093<br />
0.091<br />
0.088<br />
0.086<br />
0.084<br />
Ground<br />
120<br />
145<br />
170<br />
210<br />
250<br />
285<br />
315<br />
355<br />
410<br />
460<br />
520<br />
Duct<br />
100<br />
120<br />
145<br />
175<br />
210<br />
240<br />
270<br />
300<br />
350<br />
390<br />
440<br />
0.137<br />
0.128<br />
0.124<br />
0.120<br />
0.116<br />
0.111<br />
0.108<br />
0.106<br />
0.101<br />
0.098<br />
0.095<br />
0.093<br />
0.091<br />
Air<br />
125<br />
155<br />
190<br />
235<br />
290<br />
330<br />
375<br />
435<br />
510<br />
590<br />
670<br />
UNARM<br />
12.7/ 22 KV<br />
ARM<br />
/Km /Km<br />
0.130<br />
0.121<br />
0.116<br />
0.112<br />
0.109<br />
0.105<br />
0.101<br />
0.099<br />
0.095<br />
0.093<br />
0.089<br />
0.087<br />
0.085<br />
Ground<br />
120<br />
145<br />
170<br />
210<br />
250<br />
280<br />
310<br />
350<br />
400<br />
445<br />
500<br />
6.6kV (E),11kV(E)<br />
& 11kV(UE)<br />
Duct<br />
105<br />
125<br />
150<br />
180<br />
215<br />
240<br />
270<br />
305<br />
350<br />
390<br />
440<br />
0.139<br />
0.130<br />
0.125<br />
0.121<br />
0.117<br />
0.113<br />
0.109<br />
0.106<br />
0.102<br />
0.100<br />
0.097<br />
0.094<br />
0.092<br />
Air<br />
135<br />
165<br />
195<br />
240<br />
295<br />
335<br />
380<br />
430<br />
500<br />
570<br />
650<br />
UNARM<br />
19/ 33 KV<br />
ARM<br />
/Km /Km<br />
0.143<br />
0.134<br />
0.128<br />
0.124<br />
0.120<br />
0.116<br />
0.111<br />
0.109<br />
0.104<br />
0.100<br />
0.097<br />
0.095<br />
0.092<br />
22kV(E) & 33kV (E)<br />
Ground<br />
-<br />
145<br />
170<br />
205<br />
245<br />
275<br />
305<br />
345<br />
395<br />
440<br />
495<br />
Duct<br />
-<br />
125<br />
150<br />
180<br />
215<br />
245<br />
275<br />
305<br />
350<br />
390<br />
440<br />
Air<br />
-<br />
0.149<br />
0.139<br />
0.134<br />
0.129<br />
0.125<br />
0.121<br />
0.116<br />
0.115<br />
0.109<br />
0.107<br />
0.103<br />
0.099<br />
0.098<br />
165<br />
200<br />
245<br />
300<br />
340<br />
385<br />
435<br />
510<br />
580<br />
660<br />
Issued: June 2012<br />
12
ELECTRICAL PARAMETERS (Tables)<br />
Table 17<br />
REACTANCE OF 3 CORE CABLES<br />
Conductor<br />
Area<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Table 18<br />
DIELECTRIC LOSSES<br />
Conductor<br />
Area<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
REACTANCE OF 3 CORE CABLES<br />
3.8/ 6.6 KV<br />
6.6/ 6.6KV &<br />
6.35/ 11 KV<br />
11/ 11 KV 12.7/ 22 KV 19/ 33 KV<br />
/Km /Km /Km /Km /Km<br />
0.101<br />
0.108<br />
0.123<br />
0.126<br />
0.143<br />
0.097<br />
0.104<br />
0.118<br />
0.121<br />
0.137<br />
0.093<br />
0.099<br />
0.112<br />
0.115<br />
0.130<br />
0.087<br />
0.093<br />
0.104<br />
0.107<br />
0.121<br />
0.084<br />
0.089<br />
0.100<br />
0.103<br />
0.116<br />
0.082<br />
0.087<br />
0.097<br />
0.100<br />
0.112<br />
0.080<br />
0.085<br />
0.094<br />
0.097<br />
0.108<br />
0.078<br />
0.082<br />
0.091<br />
0.093<br />
0.104<br />
0.076<br />
0.080<br />
0.088<br />
0.090<br />
0.101<br />
0.076<br />
0.078<br />
0.086<br />
0.088<br />
0.098<br />
0.075<br />
0.076<br />
0.083<br />
0.085<br />
0.094<br />
3.8/ 6.6 KV<br />
6.6/ 6.6KV &<br />
6.35/ 11 KV<br />
DIELECTRIC LOSSES<br />
11/ 11 KV 12.7/ 22 KV 19/ 33 KV<br />
w/ pH/Km w/ pH/Km w/ pH/Km w/ pH/Km w/ pH/Km<br />
3.943<br />
9.883<br />
20.561<br />
25.923<br />
46.097<br />
4.367<br />
10.892<br />
22.450<br />
28.250<br />
49.810<br />
4.959<br />
12.293<br />
25.063<br />
31.464<br />
54.909<br />
5.632<br />
13.884<br />
28.016<br />
35.094<br />
60.634<br />
6.344<br />
15.566<br />
31.127<br />
38.913<br />
66.628<br />
6.929<br />
16.946<br />
33.673<br />
42.038<br />
71.514<br />
7.555<br />
18.422<br />
36.390<br />
45.369<br />
76.709<br />
8.264<br />
20.091<br />
39.457<br />
49.129<br />
82.556<br />
9.180<br />
22.246<br />
43.413<br />
53.976<br />
90.075<br />
9.299<br />
23.910<br />
46.461<br />
57.709<br />
95.855<br />
9.680<br />
27.036<br />
52.184<br />
64.715<br />
106.680<br />
10.219<br />
30.061<br />
57.714<br />
71.484<br />
117.115<br />
11.382<br />
33.474<br />
63.946<br />
79.108<br />
128.852<br />
12.545<br />
36.883<br />
70.168<br />
86.720<br />
140.552<br />
13.518<br />
40.777<br />
77.270<br />
95.407<br />
153.891<br />
Issued: June 2012<br />
13
ELECTRICAL PARAMETERS (Tables)<br />
Table 19<br />
RESISTANCES<br />
Conductor<br />
Area<br />
mm²<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
500<br />
630<br />
800<br />
1000<br />
D C RESISTANCE AT 20° C A C RESISTANCE AT 90° C<br />
ALUMINIUM COPPER ALUMINIUM COPPER<br />
1.20<br />
0.868<br />
0.641<br />
0.443<br />
0.320<br />
0.253<br />
0.206<br />
0.164<br />
0.125<br />
0.100<br />
0.0778<br />
0.0605<br />
0.0469<br />
0.0367<br />
0.0291<br />
0.727<br />
0.524<br />
0.387<br />
0.268<br />
0.193<br />
0.153<br />
0.124<br />
0.0991<br />
0.0754<br />
0.0601<br />
0.0470<br />
0.0366<br />
0.0283<br />
0.0221<br />
0.0176<br />
1.53<br />
1.11<br />
0.818<br />
0.565<br />
0.409<br />
0.323<br />
0.264<br />
0.210<br />
0.161<br />
0.129<br />
0.102<br />
0.082<br />
0.065<br />
0.931<br />
0.671<br />
0.496<br />
0.344<br />
0.248<br />
0.197<br />
0.160<br />
0.129<br />
0.099<br />
0.080<br />
0.064<br />
0.052<br />
0.042<br />
Issued: June 2012<br />
14
RATING FACTORS<br />
Table 20<br />
RATING FACTORS FOR DEPTH OF LAYING<br />
(For cables laid directly in ground)<br />
Depth of laying<br />
(mm)<br />
500- 750<br />
750- 900<br />
900- 1050<br />
1050- 1200<br />
1200- 1500<br />
1500- 1800<br />
1.1 KV<br />
Cables<br />
1.00<br />
0.98<br />
0.96<br />
0.94<br />
0.92<br />
0.90<br />
3.3, 6.6,11 KV<br />
Cables<br />
-<br />
1.00<br />
0.99<br />
0.98<br />
0.96<br />
0.95<br />
22 & 33 KV<br />
Cables<br />
-<br />
-<br />
1.00<br />
0.99<br />
0.98<br />
0.96<br />
Table 21<br />
GROUP RATING FACTORS FOR MULTI CORE CABLES OR GROUPS OF SINGLE CORE CABLES IN HORIZONTAL FORMATION<br />
(For cables laid directly in ground)<br />
Number of cables or group of single core<br />
cables in same trench<br />
Spacing between cables or groups touching<br />
70 mm<br />
250 mm<br />
2 3<br />
4 5<br />
6<br />
0.79<br />
0.85<br />
0.87<br />
0.69<br />
0.75<br />
0.79<br />
Table 22<br />
GROUP RATING FACTORS FOR MULTI CORE CABLES OR GROUPS OF SINGLE CORE CABLES IN AIR ON LADDER SUPPORTS, METAL TRAYS , WALLS<br />
etc WITH MAINTAINED SPACING BETWEEN CABLES OR GROUPS<br />
Number of cables or group of single core cables<br />
Vertically<br />
1<br />
2<br />
3<br />
0.93<br />
0.83<br />
0.76<br />
0.63<br />
0.68<br />
0.75<br />
0.58<br />
0.64<br />
0.72<br />
0.55<br />
0.60<br />
0.69<br />
1 2<br />
Horizontally<br />
3 4<br />
5<br />
1.00<br />
0.89<br />
0.80<br />
0.87<br />
0.79<br />
0.72<br />
0.84<br />
0.76<br />
0.70<br />
0.83<br />
0.75<br />
0.69<br />
4 0.77 0.72 0.68 0.67 0.66<br />
Table 23<br />
RATING FACTORS FOR VARIATION IN GROUND TEMPERATURE<br />
(For cables laid directly in ground)<br />
GROUND TEMPERATURE ° C<br />
RATING FACTOR<br />
15<br />
1.12<br />
20<br />
1.08<br />
Table 24<br />
RATING FACTORS FOR VARIATION IN AMBIENT AIR TEMPERATURE<br />
AIR TEMPERATURE ° C<br />
RATING FACTOR<br />
20<br />
1.18<br />
25<br />
1.14<br />
Table 25<br />
RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL<br />
Voltage rating of cables<br />
1.1 & 3.3 KV<br />
6.6, 11 & 22 KV<br />
33 KV<br />
25<br />
1.04<br />
30<br />
1.10<br />
30<br />
1.0<br />
35<br />
1.05<br />
35<br />
0.96<br />
40<br />
1.0<br />
40<br />
0.91<br />
45<br />
0.95<br />
45<br />
0.87<br />
50<br />
0.89<br />
Thermal resistivity of soil (° C cm/W)<br />
100<br />
1.18<br />
120<br />
1.08<br />
150<br />
1.0<br />
200<br />
0.88<br />
250<br />
0.81<br />
0.16 1.08 1.0<br />
0.90 0.83<br />
0.12 1.07 1.0<br />
0.90 0.83<br />
50<br />
0.82<br />
55<br />
0.84<br />
300<br />
0.74<br />
0.76<br />
0.78<br />
6<br />
0.82<br />
0.74<br />
0.68<br />
0.65<br />
Issued: June 2012<br />
15
PROCESS FLOW CHART: XLPE INSULATED POWER CABLES (upto 33 kV GRADE)<br />
RAW MATERIALS<br />
ALUMINIIUM/ COPPER<br />
WIRE DRAWING<br />
A<br />
CONDUCTOR STRANDING<br />
XLPE COMPOUND<br />
SEMICONDUCTING COMPOUND XLPE TRUE TRIPLE EXTRUSION<br />
COPPER TAPE<br />
COL. IDENTIFICATION TAPE<br />
FILLERS<br />
PVC TAPE/<br />
PVC COMPOUND<br />
GALVANISED STEEL<br />
FLAT STRIPS/<br />
ROUND WIRES<br />
(A-I QUALITY CHECKPOINTS)<br />
3 CORE<br />
B<br />
C<br />
COPPER TAPING<br />
D<br />
LAYING UP OF CORES<br />
E<br />
INNER SHEATHING<br />
(TAPED/ EXTRUDED)<br />
F<br />
ARMOURING<br />
G<br />
1 CORE<br />
PACKING<br />
OUTER SHEATHING H<br />
I<br />
Issued: June 2012<br />
16
sterlitetechnologies.com<br />
China<br />
Denmark<br />
India<br />
Netherlands<br />
Russia<br />
South Africa<br />
Taiwan<br />
Turkey<br />
United Arab Emirates<br />
United Kingdom<br />
United States of America<br />
About <strong>Sterlite</strong><br />
<strong>Sterlite</strong> Technologies Limited is a leading global<br />
provider of connectivity solutions for the<br />
telecom & power industries.<br />
Equipped with a suite that includes power<br />
conductors, power cables, optical fibers, fiber<br />
cables, data cables and a comprehensive<br />
telecom solutions portfolio, <strong>Sterlite</strong>'s vision is to<br />
'Connect every home on the planet'. <strong>Sterlite</strong> is<br />
also executing multi-million dollar power<br />
transmission system projects, pan-India.<br />
email: communications@sterlite.com<br />
RECYCLABLE June 2012