DIMENSION AND WEIGHT (Tables)<br />
Table 05<br />
Single-core 11/11 KV Cables<br />
Single wire Armoured cables with Aluminium conductors<br />
Single Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, PVC type ST 2 inner sheathed, Aluminium wire Armoured, PVC type ST 2 outer sheathed 11/11<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code: A2XWaY<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
630<br />
800<br />
1000<br />
Nominal area<br />
of conductor<br />
Sq.mm<br />
25<br />
35<br />
50<br />
70<br />
95<br />
120<br />
150<br />
185<br />
240<br />
300<br />
400<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
Nominal<br />
Thickness of<br />
insulation<br />
mm<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
5.5<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.3<br />
0.3<br />
0.3<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.4<br />
0.5<br />
0.5<br />
0.6<br />
0.6<br />
Table 06<br />
Three-core 11/11 KV<br />
strip Armoured cables with Aluminium conductors<br />
Three Core Aluminium Conductor Extruded Semi conducting compound screened, XLPE insulated, Semi conducting compound<br />
screened, helical copper tape wrapped, Taped PVC type ST 2 inner sheathed, Steel strip Armoured, PVC type ST 2 outer sheathed 11/11<br />
KV cable conforming to IS 7098 (Part-2):1985 with latest amendments. Code:A2XFY(T)<br />
Minimum<br />
Thickness of<br />
inner sheath<br />
mm<br />
0.5<br />
0.6<br />
0.6<br />
0.6<br />
0.6<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
0.7<br />
Nominal<br />
diameter of<br />
armour<br />
mm<br />
1.6<br />
1.6<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.0<br />
2.5<br />
2.5<br />
2.5<br />
Nominal<br />
Dimension<br />
of Armour<br />
mm<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
4 x 0.8<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.56<br />
1.72<br />
1.72<br />
1.88<br />
2.04<br />
2.20<br />
2.36<br />
Minimum<br />
Thickness of<br />
outer sheath<br />
mm<br />
1.88<br />
2.04<br />
2.20<br />
2.20<br />
2.36<br />
2.36<br />
2.52<br />
2.68<br />
2.84<br />
3.00<br />
3.00<br />
Approx<br />
overall<br />
dia<br />
mm<br />
30.2<br />
31.7<br />
34.2<br />
35.5<br />
37.0<br />
38.8<br />
41.5<br />
43.0<br />
46.5<br />
54.5<br />
58.7<br />
63.0<br />
App<br />
overall<br />
diameter<br />
mm<br />
48.5<br />
51.5<br />
54.5<br />
58.0<br />
62.0<br />
65.5<br />
69.0<br />
73.0<br />
78.0<br />
82.0<br />
89.0<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
1070<br />
1200<br />
1420<br />
1550<br />
1700<br />
1840<br />
2200<br />
2420<br />
2880<br />
4030<br />
4800<br />
5600<br />
Approx<br />
Cable<br />
Weight<br />
kg/km<br />
2670<br />
3010<br />
3360<br />
3800<br />
4390<br />
4880<br />
5430<br />
6120<br />
7080<br />
7970<br />
9360<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
Standard<br />
packing<br />
length<br />
metres<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
500<br />
400<br />
350<br />
250<br />
200<br />
Issued: June 2012<br />
7