<strong>EL</strong>-<strong>6890</strong><br />

PC Interface Software<br />

User’s Guide<br />

What Does PC Interface Software Do?<br />

Backup Backs up all <strong>EL</strong>-<strong>6890</strong> data to<br />

your PC.<br />

Restore Restores data from a backup<br />

file into an <strong>EL</strong>-<strong>6890</strong>.<br />

Address Utility Allows you to type in an<br />

address, E-mail or WWW<br />

entry on a PC and download it<br />

into your <strong>EL</strong>-<strong>6890</strong>.<br />

Supplied Items<br />

* One 3.5" Floppy Disk (PC Interface Software)<br />

* PC Interface Cable<br />

* PC Interface Software User's Guide (this sheet)<br />

Please contact your nearest SHARP dealer if<br />

any of the above items are missing from the<br />

<strong>EL</strong>-<strong>6890</strong>P package or are damaged.<br />

Getting Started<br />

Known Incompatibilities<br />

• While you are backing up or restoring data, a<br />

transfer error may occur with certain 3D<br />

screen saver utility programs enabled. Before<br />

transferring data, disable any 3D screen saver<br />

utility programs you may be running.<br />

• PC Interface Software may not run reliably<br />

with certain virus scanning programs enabled.<br />

If you have problems in transferring data with<br />

your <strong>EL</strong>-<strong>6890</strong>, disable any virus checking<br />

software you may be running.<br />

• PC Interface Software may not run reliably<br />

with certain power management features<br />

enabled. If you have problems in transferring<br />

data with your <strong>EL</strong>-<strong>6890</strong>, disable any power<br />

management features you may have turned<br />

on.<br />

System Requirements<br />

• Windows ® 2000 Professional, Windows ® 98,<br />

or Windows ® 95<br />

• 8MB free hard disk space<br />

• VGA monitor or better<br />

• Microsoft ® Mouse or compatible Pointing<br />

Device<br />

• 3.5” disk drive<br />

• One available serial port with D-sub 9-pin<br />

connector<br />

And for Windows ® 2000 Professional:<br />

• 133MHz or higher Pentium-compatible CPU<br />

• 64MB RAM available<br />

And for Windows ® 98, Windows ® 95:<br />

• IBM-compatible 486 or Pentium-compatible<br />

CPU (66MHz or higher)<br />

• 24MB RAM available<br />

PC Interface Software Main Screen<br />

All operations can be accessed from the Main<br />

Screen.<br />

To access the Main Screen, click [Start] ➝<br />

[Program] ➝ [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>] ➝ [EO-Utility].<br />

Before You Begin<br />

Connecting Your <strong>EL</strong>-<strong>6890</strong> to a PC<br />

PC Interface Cable<br />

(supplied)<br />

1. Turn off your PC and the <strong>EL</strong>-<strong>6890</strong>.<br />

2. Connect the standard 9-pin connector of the<br />

PC interface cable into a COM port on your<br />

PC.<br />

NOTE<br />

* Using a 25-pin connector instead of the<br />

standard 9-pin connector requires an<br />

additional adaptor.<br />

3. Connect the other end of the PC Interface<br />

Cable into the PC interface connector<br />

located on the left side of the <strong>EL</strong>-<strong>6890</strong>.<br />

Setting the COM port<br />

Your PC<br />

<strong>EL</strong>-<strong>6890</strong><br />

E R<br />

A S D<br />

Z X<br />

1. Connect your <strong>EL</strong>-<strong>6890</strong> to a PC.<br />

2. Click [Start] ➝ [Program] ➝ [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>]<br />

➝ [EO-Utility].<br />

The PC Interface Software Main Screen<br />

appears.<br />

3. Click [COM port...].<br />

The COM port setting dialog box appears.<br />

* Click the radio button to select an<br />

appropriate port, or<br />

* Click [Auto Detect...]<br />

to allow an<br />

appropriate port to<br />

be selected<br />

automatically.<br />

COMPUTER LINK<br />

Q<br />

W<br />

4 5<br />

1<br />

1<br />

2nd<br />

Installing<br />

1. Insert the PC Interface Software disk into<br />

your disk drive.<br />

2. Click on the Windows [Start] button and then<br />

click [Run].<br />

3. Type in a:\Setup.exe and click on [OK].<br />

• Type in your disk drive name ("a:" in this<br />

example).<br />

4. Follow the on-screen instructions.<br />

The software is installed into the following<br />

location and can be accessed in the<br />

following directory:<br />

C:\Program Files\<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>\<br />

Application: [Start] ➝ [Program] ➝ [<strong>Sharp</strong><br />

<strong>EL</strong>-<strong>6890</strong>] ➝[EO-Utility]<br />

ReadMe : [Start] ➝ [Program] ➝ [<strong>Sharp</strong><br />

<strong>EL</strong>-<strong>6890</strong>] ➝[ReadMe]<br />

You are recommended not to change the<br />

default folder name: [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>].<br />

5. Click [Finish].<br />

NOTE<br />

* When you are using a notebook PC, an error<br />

message may be displayed when you click<br />

[Auto Detect...]. Check the BIOS setting on<br />

your notebook PC and set it to the serial port.<br />

Even when the BIOS setting is correctly<br />

made, you may need to select an appropriate<br />

port manually.<br />

SHARP CORPORATION<br />

PRINTED IN CHINA<br />

00CTO(TINSE0385EHZZ)


Backup and Restore<br />

Making a Backup File<br />

1. Connect your <strong>EL</strong>-<strong>6890</strong> to a PC.<br />

2. Click [Start] ➝ [Program] ➝ [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>]<br />

➝ [EO-Utility].<br />

The PC Interface Software Main Screen<br />

appears.<br />

3. Click [Backup].<br />

The dialog box appears asking you to enter<br />

the backup file name, if necessary.<br />

* The default name is determined according<br />

to the PC clock system, in the format of<br />

"YYYYMMDD.BKE", for example,<br />

20010101.BKE.<br />

* [Browse...] allows you to change the<br />

backup file, its file name and its destination.<br />

NOTE<br />

* When the COM port has not been selected,<br />

the warning message dialog box appears.<br />

Click [OK]. Then click [COM port...] on the<br />

Main Screen and select the appropriate port.<br />

4. Click [NEXT >>] to start the backup process.<br />

The instructions screen appears.<br />

• To cancel the backup process, click [Abort]<br />

on the instructions screen.<br />

5. On your <strong>EL</strong>-<strong>6890</strong>:<br />

Press 2nd OPTION and 4 to select<br />

“4: BACKUP”. Then press Y to start the<br />

backup process.<br />

Restoring a Backup File<br />

"Restore" function replaces all the data in the<br />

<strong>EL</strong>-<strong>6890</strong> with the backup file saved on a PC.<br />

NOTE<br />

* Make sure you really want to delete all the<br />

data in your <strong>EL</strong>-<strong>6890</strong> before executing the<br />

"Restore" function. Once you start the<br />

restoration process, all the data in the <strong>EL</strong>-<br />

<strong>6890</strong> will be deleted, even if you cancel the<br />

restoration process.<br />

1. Connect your <strong>EL</strong>-<strong>6890</strong> to a PC.<br />

2. Click [Start] ➝ [Program] ➝ [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>]<br />

➝ [EO-Utility].<br />

The PC Interface Software Main Screen<br />

appears.<br />

3.Click [Restore].<br />

The dialog box appears asking you to<br />

choose the backup file name.<br />

4. Click [NEXT >>] to start the restoration<br />

process.<br />

The confirmation dialog box appears.<br />

• To cancel the restoration process, click<br />

[NO].<br />

5. Click [YES].<br />

The instructions screen appears.<br />

• To cancel the restoration process, click<br />

[Abort] on the instructions screen.<br />

6. On your <strong>EL</strong>-<strong>6890</strong>:<br />

Press 2nd OPTION and 5 to select<br />

“5: RESTORE”.<br />

The data transfer is started.<br />

Address Utility<br />

Click [Address Utility] on the Main Screen to<br />

open the Address Utility window.<br />

Command Buttons<br />

Entry fields of T<strong>EL</strong>/E-mail<br />

mode<br />

Mode tabs<br />

Switch the mode window<br />

between T<strong>EL</strong>/E-mail mode<br />

and WWW mode.<br />

Secret button<br />

Sets this data as secret.<br />

Click on this area.<br />

: Secret ON : Secret OFF<br />

Entering an Address<br />

Send button<br />

Transfers the data<br />

to your <strong>EL</strong>-<strong>6890</strong>.<br />

New button<br />

Clears the input<br />

data in all entry<br />

fields to create<br />

new data.<br />

Done button<br />

Closes the<br />

dialog window.<br />

Enter the following data as secret<br />

data in T<strong>EL</strong>/E-mail mode.<br />

Name Edwards Bob<br />

Number 201-265-5600<br />

F 265-1234<br />

Address Supervisor Sales dept.<br />

ABCD co. 15 North St.<br />

E-mail edwards@abcd.efg.com<br />

1. Connect your <strong>EL</strong>-<strong>6890</strong> to a PC.<br />

2. Click [Start] ➝ [Program] ➝ [<strong>Sharp</strong> <strong>EL</strong>-<strong>6890</strong>]<br />

➝ [EO-Utility].<br />

The PC Interface Software Main Screen<br />

appears.<br />

3. Click [Address Utility].<br />

4. Click [T<strong>EL</strong>/E-mail] tab.<br />

5. Click [New] to clear the input data in all entry<br />

fields.<br />

6. Enter the information.<br />

• The cursor appears in the entry field you<br />

click for input.<br />

7. (After entering the information), click [Send].<br />

The instructions screen appears.<br />

• To cancel the transferring process, click<br />

[Abort] on the instructions screen.<br />

8. On your <strong>EL</strong>-<strong>6890</strong>:<br />

Press 2nd OPTION and 2 to select<br />

“2: RECV ” (RECEIVE).<br />

If the transferred data is displayed on the<br />

display of the <strong>EL</strong>-<strong>6890</strong>, the transferring<br />

process is completed.<br />

NOTES<br />

* Do not forget to fill in the Name field before<br />

clicking [Send]. Otherwise, the data you typed<br />

in can not be sent.<br />

* You can not enter the characters or symbols<br />

not supported by the <strong>EL</strong>-<strong>6890</strong> in the entry<br />

fields.<br />

In U.S.A.<br />

Customer <strong>Support</strong><br />

www.sharp-usa.com <strong>Sharp</strong> Web Site<br />

Information and FAQs<br />

1-630-378-3590 <strong>Sharp</strong> Customer Assistance<br />

Center<br />