THE SHPP KALJANI<br />

Two Francis Units versus Two Cross-flow Units<br />

Criteria (No.1)…..Annual generati<strong>on</strong>:<br />

Variant II: 2 x Cross flow unit … Hn = 36,5 m; Qi = 2 x 2,0 m3/s<br />

Flow rate 100% 90% 60% 30% 17%<br />

Output kW 610 549 366 183 101<br />

Flow rate l/s 2000 1800 1200 600 340<br />

Efficiency (%) ( ή ) 84 84 84 83 81<br />

Annual generati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> Variant II: ....... 4,68 GWh