European Technical Approval ETA-06/0157 - ETA-Danmark
European Technical Approval ETA-06/0157 - ETA-Danmark
European Technical Approval ETA-06/0157 - ETA-Danmark
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>ETA</strong>-<strong>Danmark</strong> A/S<br />
Kollegievej 6<br />
DK-2920 Charlottenlund<br />
Tel. +45 72 24 59 00<br />
Fax +45 72 24 59 04<br />
Internet www.etadanmark.dk<br />
Authorised and notified according to<br />
Article 10 of the Council Directive<br />
89/1<strong>06</strong>/EEC of 21 December 1988 on<br />
the approximation of laws, regulations<br />
and administrative provisions of<br />
Member States relating to construction<br />
products<br />
<strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
MEMBER OF EOTA<br />
This <strong>ETA</strong> is a renewal of the previous <strong>ETA</strong> with the same number and validity from 20<strong>06</strong>-09-<strong>06</strong> to 2011-09-<strong>06</strong><br />
Trade name:<br />
Holder of approval:<br />
Generic type and use of construction<br />
product:<br />
Valid from:<br />
to:<br />
Manufacturing plant:<br />
This <strong>European</strong> <strong>Technical</strong><br />
<strong>Approval</strong> contains:<br />
DERBIGUM SP 4 FR single layer roof-waterproofing<br />
kit and DERBICOLOR 4 WSL single layer roofwaterproofing<br />
kit<br />
Imperbel S. A.<br />
Parc Industriel<br />
B-1360 Perwez<br />
Tel. +32 81 65 44 11<br />
Fax +32 81 65 43 09<br />
Single layer mechanically fastened roof-waterproofing<br />
kit<br />
2011-09-<strong>06</strong><br />
2016-09-<strong>06</strong><br />
Imperbel S. A.<br />
Parc Industriel<br />
B-1360 Perwez<br />
23 pages including 4 Annexes which form an integral<br />
part of the document
I LEGAL BASIS AND GENERAL<br />
CONDITIONS<br />
Page 2 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
1 This <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> is issued by<br />
<strong>ETA</strong>-<strong>Danmark</strong> A/S in accordance with:<br />
- Council Directive 89/1<strong>06</strong>/EEC of 21 December<br />
1988 on the approximation of laws, regulations<br />
and administrative provisions of Member States<br />
relating to construction products 1) , as amended by<br />
Council Directive 93/68/EEC of 22 July 1993 2) .<br />
- Bekendtgørelse 559 af 27-<strong>06</strong>-1994 (afløser<br />
bekendtgørelse 480 af 25-<strong>06</strong>-1991) om ikrafttræden<br />
af EF direktiv af 21. december 1988 om<br />
indbyrdes tilnærmelse af medlemsstaternes love<br />
og administrative bestemmelser om byggevarer.<br />
- Common Procedural Rules for Requesting,<br />
Preparing and the Granting of <strong>European</strong> <strong>Technical</strong><br />
<strong>Approval</strong>s set out in the Annex to Commission<br />
Decision 94/23/EC 3) .<br />
- Guideline for <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> of<br />
Mechanically fastened roof-waterproofing kits,<br />
<strong>ETA</strong>-Guideline N o 0<strong>06</strong>, Edition March 2000.<br />
2 <strong>ETA</strong>-<strong>Danmark</strong> A/S is authorized to check whether<br />
the provisions of this <strong>European</strong> <strong>Technical</strong><br />
<strong>Approval</strong> are met. Checking may take place in the<br />
manufacturing plant. Nevertheless, the responsibility<br />
for the conformity of the products to the<br />
<strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> and for their fitness<br />
for the intended use remains with the holder of<br />
the <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong>.<br />
3 This <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> is not to be<br />
transferred to manufacturers or agents of manufacturers<br />
other than those indicated on page 1, or<br />
manufacturing plants other than those indicated<br />
on page 1 of this <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong>.<br />
4 This <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> may be<br />
withdrawn by <strong>ETA</strong>-<strong>Danmark</strong> A/S pursuant to<br />
Article 5(1) of Council Directive89/1<strong>06</strong>/EEC.<br />
1) Official Journal of the <strong>European</strong> Communities N o L40, 11 Feb 1989, p 12.<br />
2) Official Journal of the <strong>European</strong> Communities N o L220, 30 Aug 1993, p 1.<br />
3) Official Journal of the <strong>European</strong> Communities N o L 17, 20 Jan 1994, p 34.<br />
5 Reproduction of this <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong><br />
including transmission by electronic means shall be<br />
in full. However, partial reproduction can be made<br />
with the written consent of <strong>ETA</strong>-<strong>Danmark</strong> A/S. In<br />
this case partial reproduction has to be designated as<br />
such. Texts and drawings of advertising brochures<br />
shall not contradict or misuse the <strong>European</strong> <strong>Technical</strong><br />
<strong>Approval</strong>.<br />
6 This <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> is issued by<br />
<strong>ETA</strong>-<strong>Danmark</strong> A/S in Danish.<br />
This version corresponds fully to the version circulated<br />
within EOTA. Translations into other languages<br />
have to be designated as such.
Page 3 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
II SPECIAL CONDITIONS OF THE<br />
EUROPEAN TECHNICAL APPROVAL<br />
1 Definition of product and intended use<br />
Description of the kit<br />
DERBIGUM SP 4 FR is a single layer mechanically fastened roof-waterproofing kit, which consists of a membrane<br />
and a specified fastening system. The membrane is fastened through an insulation material into the substrate.<br />
DERBICOLOR 4 WSL is a single layer mechanically fastened roof-waterproofing kit, which consists of a membrane<br />
and a specified fastening system. The membrane is fastened through an insulation material into the substrate.<br />
The mineral wool boards are not part of the kit.<br />
DERBIGUM SP 4 FR and DERBICOLOR 4 WSL are also placed on the market with the designation DERBIGUM<br />
SP 4 FM and DERBICOLOR 4 FM respectively.<br />
Membranes<br />
DERBIGUM SP 4 FR is a membrane made from polymer modified bitumen (APP) with a double-layer reinforcement<br />
in the top layer of the membrane of approx. 150 g/m 2 non-woven polyester felt and 55 g/m 2 fibreglass. DERBIGUM<br />
SP 4 FR has a total thickness of 4 mm and a weight of 4,3 kg/m 2 . Standard width is 1,10 m.<br />
DERBICOLOR 4 WSL is a membrane made from polymer modified bitumen (APP) with reinforcement complex in<br />
the middle layer of the membrane of approx. 210 g/m 2 non-woven polyester felt and fibreglass. DERBICOLOR has a<br />
total thickness of 4 mm and a weight of 5,3 kg/m 2 . Standard width is 1,10 m.<br />
The membranes are supplied in roll form<br />
The different membranes and fasteners which can compose the mechanically fastened flexible roof waterproofing<br />
membrane kit (in the following referred to as MEFAWAME) and their properties are presented in Annexes 1 and<br />
2. The holder of the <strong>ETA</strong> is fundamentally responsible of the MEFAWAME. The flexible membranes which<br />
constitute the MEFAWAME are exclusively distributed by Imperbel S.A, subsidiary companies and distributors.<br />
Fasteners<br />
The different fasteners, manufactured by different manufacturers (SFS INTEC or LR <strong>ETA</strong>NCO), depend on the<br />
substrate:<br />
Profiled metal decking substrate (standard)<br />
• screw IR2 4.8xL + plate IR 82x40 (manufacturer SFS INTEC)<br />
• screw IR2S 4.8xL + plate IR 82x40 (manufacturer SFS INTEC)<br />
• screw EHBDF2C 4.8xL + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVDF2C 4.8xL + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVDF2C 4.8xL + plate 82x40R SC (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw VMS2C 4.8xL + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVF2C 4.8xL + plate 82x40 R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVF2C 4.8xL + plate 82x40R SC (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw ISODRILL TT + plate Etancoplast T80x40 (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EGB2C 4.8XL + plate Etancoplast T80x40 (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw ISODRILL TT + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw ISODRILL TH DF + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)
Page 4 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Perforated Profiled metal decking substrate (acoustic)<br />
• screw IFP2 6.7xL + plate IRP 82x40 (manufacturer SFS INTEC)<br />
• screw TPR 6.3xL + IRD 82x40 (manufacturer SFS INTEC)<br />
• screw FASTOVIS 3036 TF DF + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• rivet PER/RER + 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
Concrete substrate<br />
• screw TI 6.3xL + plate IRD 82x40 (manufacturer SFS INTEC)<br />
• nail DT 6.3xL + plate IRD 82x40 (manufacturer SFS INTEC)<br />
• screw TI 6.3xL + plate IF/IG C 82x40 (manufacturer SFS INTEC)<br />
• screw BETOFAST TH 3C + plate 82x40R (manufacturer <strong>ETA</strong>NCO)<br />
• screw BETOFAST TH DF 3C + plate 82x40R (manufacturer <strong>ETA</strong>NCO)<br />
• screw BETOFAST TT 2C + plastic sleeve <strong>ETA</strong>NCOPLAST T80x40 (manufacturer <strong>ETA</strong>NCO)<br />
• nail NAILFIX CH + plate 82x40 R SC (manufacturer LR <strong>ETA</strong>NCO)<br />
Lightweight concrete substrate<br />
• screw IGR S 8.0xL + plate IG8 C 82x40 (manufacturer SFS INTEC)<br />
• screw MULTIFAST TB INOX A2 + 80x40R (manufacturer LR <strong>ETA</strong>NCO)<br />
Wood substrate<br />
• screw IG 6.0xL + plate IRD 82x40 (manufacturer SFS INTEC)<br />
• screw IWT 5.0xL + plate IRC/W 82x40 (manufacturer SFS INTEC)<br />
• screw EVF2C 4.8xL + plate 82x40R SC (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVDF2C 4.8xL + plate 82x40R DF (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw EVDF 2C 4.8xL + plate 82x40R SC (manufacturer LR <strong>ETA</strong>NCO)<br />
• screw MULTIFAST TF + plate 80x40R (manufacturer LR <strong>ETA</strong>NCO)<br />
All the fasteners conform to the specifications of the <strong>ETA</strong>G 0<strong>06</strong>(see Note).<br />
The flexible membranes and the fasteners are commercialised in separate transactions and assembled on site.<br />
The means of fastening are presented in annex 4.<br />
The insulation material is fastened in the centre of each insulation panel with fasteners. The number of fasteners<br />
or fasteners and the type are defined in the National Regulations and /or product certificates for the insulation<br />
materials.<br />
Note In addition to the list of fasteners, other fasteners may also be used unless they are covered by a valid<br />
<strong>ETA</strong> and with rectangular plate with dimensions of 82 × 40 (as example, the fasteners of the <strong>ETA</strong> 08/0285 from<br />
AFAST BV – Guardian Fastening System- with plate size 82 × 40)<br />
Insulation<br />
The wind uplift test has been performed on a mineral wool substrate with compressibility at 10% of 50 kPa and<br />
point load behaviour of 120 kPa, deformation 5 mm, and the values are valid for other insulation materials with<br />
the same thickness (0 mm – 350 mm) and equal or higher compressibility and point load behaviour. The<br />
insulation material is not part of the kit. The use of the insulation board as substrate for mechanically fastened<br />
roof waterproofing is defined in national provisions.<br />
Intended use<br />
DERBIGUM SP 4 FR and DERBICOLOR 4 WSL single layer roof waterproofing kit is used for waterproof covering<br />
for sloped or flat roofs. The kits are specially designed for mechanical fastening.<br />
The load bearing elements are made from steel, concrete, lightweight concrete or wood. The MEFAWAME can be<br />
installed directly on the substrate or on an insulation material. In the latter case the insulation material shall comply<br />
with the requirements mentioned above.
Page 5 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
In the manufacturer's technical dossier (MTD) 4 to this <strong>European</strong> technical approval (<strong>ETA</strong>) the manufacturer has<br />
given information concerning the substrate, which the roof waterproofing is suitable for and on how these<br />
substrates shall be pre-treated.<br />
Assumed working life<br />
The tests and assessment have been based on the assumption that the working life of DERBIGUM SP 4 FR and<br />
DERBICOLOR 4 WSL single layer roof waterproofing kits for the above described intended use is at least 10 years.<br />
This cannot be understood as a guarantee given by Imperbel S.A, subsidiary companies and distributors or <strong>ETA</strong>-<br />
<strong>Danmark</strong> A/S.<br />
4 The manufacturer's technical dossier (MTD) comprises all information necessary for the production and the processing of the<br />
product as well as for the repair of the roof waterproofing made from that. It was checked by <strong>ETA</strong>-<strong>Danmark</strong> A/S and it was found<br />
to be in accordance with the conditions stated in the approval and the characteristic values determined during the approval testing
Page 6 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
2 Characteristics of product and assessment<br />
Characteristics of products and systems<br />
The components of the roof waterproofing kit show the characteristic values with respect to the permissible<br />
tolerances which are stated in the MTD 5 to this <strong>ETA</strong>.<br />
The chemical composition and the characteristic property values of the components of the kit and the<br />
manufacturing methods are confidential and deposited with <strong>ETA</strong>-<strong>Danmark</strong> A/S.<br />
The <strong>ETA</strong> is issued for the kit on the basis of the product composition deposited with <strong>ETA</strong>-<strong>Danmark</strong> A/S.<br />
Changes to the components of the kit or in the production process of the components, which could result in the<br />
production process and/or the properties of the product deposited being incorrect should be notified to <strong>ETA</strong>-<br />
<strong>Danmark</strong> A/S before the changes are introduced. <strong>ETA</strong>-<strong>Danmark</strong> A/S will decide whether or not such changes<br />
affect the <strong>ETA</strong> and consequently the validity of the CE marking on the basis of the <strong>ETA</strong> and if so whether further<br />
assessment/alterations to the <strong>ETA</strong> shall be necessary.<br />
The performances of the membranes, the fasteners and the kits are presented in Annexes 1, 2 and 3.<br />
Methods of verification<br />
Assessment of the fitness of the roof waterproofing for the intended use with regard to the essential requirements<br />
N° 2 to N° 4 was performed following the "Guideline for <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> of systems of<br />
mechanically fastened flexible roof waterproofing membranes" (<strong>ETA</strong>G 0<strong>06</strong>).<br />
According to the manufacturer's declaration the roof waterproofing taking account of the EU database 6 does not<br />
contain any dangerous or forbidden substances.<br />
5) The manufacturer's technical dossier (MTD) comprises all information necessary for the production and the processing of the<br />
product as well as for the repair of the roof waterproofing made from that. It was checked by <strong>ETA</strong>-<strong>Danmark</strong> A/S and it was found<br />
to be in accordance with the conditions stated in the approval and the characteristic values determined during the approval testing.<br />
6) In accordance with http://europa.eu.int-/comm/enterprise/construction/internal/dangsub/dangmain.htm In addition to the specific<br />
clauses relating to dangerous substances contained in this <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong>, there may be other requirements<br />
applicable to the products falling within its scope (e.g. transposed <strong>European</strong> legislation and national laws, regulations and<br />
administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also<br />
to be complied with, when and where they apply.
Page 7 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
3 Attestation of Conformity and CE marking<br />
3.1 Attestation of Conformity system<br />
The attestation of conformity applied to this product specified by the <strong>European</strong> Commission in Mandate Construct<br />
98/143EC of February 1998, Annex 3 is System 2+ and provides:<br />
a) Tasks for the manufacturer:<br />
(1) Initial type testing of the product<br />
(2) Factory production control,<br />
b) Tasks for the notified body:<br />
(1) Initial inspection of factory and of factory production control (FPC)<br />
(2) Continuous surveillance, assessment and approval of factory production control<br />
3.2 Responsibilities<br />
3.2.1 Tasks for the manufacturer<br />
3.2.1.1 Factory production control.<br />
The manufacturer of the membrane has a factory production control system in the plant and exercises permanent<br />
internal control of production. All the elements, requirements and provisions adopted by the manufacturer are<br />
documented in a systematic manner in the form of written policies and procedures. This production control system<br />
ensures that the product is in conformity with the <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong>.<br />
The manufacturers of the fasteners have a factory production control system in the plant and exercises permanent<br />
internal control of production. All the elements, requirements and provisions adopted by the manufacturer are<br />
documented in a systematic manner in the form of written policies and procedures. This production control system<br />
ensures that the product is in conformity with the <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong>.<br />
The manufacturer of membranes and fasteners may only use raw materials or components stated in the technical<br />
documentation of this <strong>European</strong> technical approval.<br />
The factory production control shall be in accordance with the "Control Plan” relating to the <strong>European</strong> technical<br />
approval <strong>ETA</strong> - which is part of the technical documentation of this <strong>European</strong> technical approval. The "Control<br />
Plan" is laid down in the context of the factory production control system operated by the manufacturer and<br />
deposited at <strong>ETA</strong>-<strong>Danmark</strong> A/S. 7<br />
The results of factory production control shall be recorded and evaluated in accordance with the provisions of the<br />
"Control Plan".<br />
The results of factory production control are recorded and evaluated. The records include at least the following<br />
information:<br />
• Designation of the product, basic material and components;<br />
• Type of control or testing;<br />
• Date of manufacture of the product and date of testing of the product or basic material and components;<br />
• Result of control and testing and, if appropriate, comparison with requirements;<br />
• Signature of person responsible for factory production control.<br />
The records shall be presented to <strong>ETA</strong>-<strong>Danmark</strong> A/S on request<br />
3.2.1.2 Initial type testing of the product<br />
7 The "control plan" is a confidential part of the <strong>European</strong> technical approval and only handed over to the approved body or bodies<br />
involved in the procedure of attestation of conformity. See section 3.2.2.
Page 8 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
For initial type-testing the results of the tests performed as part of the assessment for the <strong>European</strong> <strong>Technical</strong><br />
<strong>Approval</strong> shall be used unless there are changes in the production line or plant. In such cases the necessary initial type<br />
testing has to be agreed between <strong>ETA</strong>-<strong>Danmark</strong> A/S and the manufacturer.<br />
3.2.1.3 Other tasks of the manufacturer<br />
The manufacturer shall, on the basis of a contract, involve a body which is notified for the tasks referred to in section<br />
3, in the field of the product in order to undertake the actions laid down in section 3.2.2. For this purpose, the control<br />
plan referred to in section 3.2.2 shall be handed over by the manufacturer to the notified body involved.<br />
3.2.2 Tasks of notified bodies<br />
3.2.2.1 Initial inspection of factory and production control.<br />
<strong>ETA</strong>-<strong>Danmark</strong> A/S ascertains that, in accordance with the MTD, factory conditions and production control allow<br />
the manufacturer to ensure the consistency and homogeneity of the manufactured product and its traceability,<br />
thus guaranteeing that the final characteristics of the product are those indicated in chapter 2.<br />
3.2.2.2 Continuous surveillance, assessment and approval of Factory Production Control<br />
The Notified Body shall visit the factory of flexible membranes at least once a year.<br />
Surveillance of the manufacturing processes shall include:<br />
• Checking the documentation of factory production control, to ensure continuing compliance with the<br />
provisions of the <strong>ETA</strong>,<br />
• Identification of changes by comparing data obtained during the initial inspection or during the last<br />
inspection.<br />
In the event the <strong>ETA</strong> provisions are not complied with, the certificate of conformity shall be withdrawn and<br />
<strong>ETA</strong>-<strong>Danmark</strong> A/S will be informed without delay.<br />
3.3 CE Marking<br />
The CE marking shall be affixed on the kit, components itself/themselves, an attached label, the packaging, or the<br />
accompanying commercial document.<br />
The required information to accompany the symbol ‘’CE’’ is:<br />
• name or identifying name of the producer<br />
• number of the notified body<br />
• last two digits of the year in which the CE marking was affixed<br />
• Number of the certificate of conformity of the Factory Production Control (System 2+)<br />
• number of the <strong>ETA</strong><br />
• <strong>ETA</strong>G 0<strong>06</strong><br />
The components shall be marked as belonging to the kit DERBIGUM SP 4 FR or DERBICOLOR 4 WSL.
Page 9 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
4 Assumptions under which the fitness of the product for the intended use was favourably<br />
assessed<br />
4.1 Installation and design<br />
Annex 4 contains detailed information on installation and design. The information comprises the following:<br />
Principle sketches:<br />
• type of mechanical fastening of membranes<br />
• type of arranging of fasteners at upstands and penetrations<br />
Membrane:<br />
Seam overlap according to detailing<br />
Fastening:<br />
Design of fastener spacing and areas according to national requirements<br />
Spacing of fasteners (according to kind of fastening)<br />
Design of perimeter and edge fixation<br />
Fastening to supporting construction<br />
Design principles of up-stands and flashings<br />
Design principles of penetrations fastening of installed parts/units according to national requirements<br />
The flexible membranes manufacturer’s installation guide forms part of this <strong>ETA</strong>.<br />
The design of the roof intended to be covered by the mechanically fastened roof waterproofing system should<br />
take account of the following factors:<br />
• Dead and imposed loads<br />
• Design wind pressure<br />
• Structural strength, stiffness and deflection limits<br />
• Attachment of the roof deck to the structural framing<br />
• Provision of insulation<br />
• Assessment of condensation risk and provision of vapour control layers<br />
• Sound insulation<br />
• Fire precautions<br />
• Roof attachments, fixtures and penetrations<br />
• Falls and drainage<br />
• Means of access for inspection and maintenance<br />
4.2 Substrates<br />
The substrate onto which the waterproofing kit is to be laid should be sufficiently rigid, dense, and dimensionally<br />
stable to support the system (membrane +insulation). Its nature will depend on the type of roof selected (warm<br />
deck, cold deck or inverted) and in turn will have a direct influence on the method of attachment.<br />
In order to support the loads imposed by traffic, insulation materials for use in warm decks should be capable of<br />
resisting permanent deformation or damage when subjected to concentrated loads. They should have a dust-free<br />
surface and sufficient laminar strength to resist with a margin of safety and stress imposed by wind uplift forces.
Page 10 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
It shall be ensured that the insulation material on site has a 10% compression of at least 50 kPa and a point load<br />
behaviour of 120 kPa, deformation 5 mm. The use of the insulation board as substrate for mechanically fastened<br />
roof waterproofing is defined in national provisions.<br />
4.3 Flexible membranes manufacturer’s responsibilities<br />
It is the manufacturer's responsibility to make sure that all those who use the kit are appropriately informed about<br />
the specific conditions according to sections 1, 2, 4, and 5 including the annexes to this <strong>ETA</strong> and the not<br />
confidential parts of the MTD to this <strong>ETA</strong>.<br />
5 Recommendations<br />
5.1 Packaging, transport and storage<br />
This product is neither toxic nor inflammable, so it is not necessary to follow any safety instructions for transport<br />
and handling.<br />
Rolls must always be stored vertically.<br />
The product must keep away from any source of heat, sparks, flame, etc.<br />
5.2 Maintenance and repair of the works<br />
The assessment of the fitness for use is based on the assumption that a normal maintenance of the system is<br />
performed.<br />
This maintenance shall include:<br />
• inspections of the roof at regular interval, e.g. twice a year. This inspection should include:<br />
o cleaning of downpipes and leaf filters<br />
o removal of stones, branches and leafs…<br />
o inspection of flashings along the edge of the roof, chimneys, drains and roof lights<br />
o removal of organic growths such as vines<br />
• Flashings to chimneys, roof edges, skylights, caps, drains etc. should be inspected every 5 years and<br />
corrected or replaced if necessary<br />
• Abrasion and minor impact damage shall be repaired.<br />
When replacing components they shall be approved by the manufacturer and covered by the <strong>ETA</strong>.<br />
Thomas Bruun<br />
Manager, <strong>ETA</strong>-<strong>Danmark</strong> A/S
Page 11 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Annex 1<br />
Characteristics of membranes (manufacturers declared values)<br />
MEMBRANE Expression of result DERBIGUM SP4 DERBICOLOR 4<br />
WSL<br />
Reference<br />
Reaction to fire Euroclass Euroclass E Euroclass F EN 13501-1<br />
Peel resistance of joint MDV(±20%) 60 N/50 mm 90 N/50 mm EN 12316-1<br />
Shear resistance of joint MDV (±10%) 560 N/50 mm 950 N/50 mm EN 12317-1<br />
Tear resistance (nail) Long<br />
MDV(±20%)<br />
200 N<br />
300 N<br />
EN 12310-1<br />
Trans<br />
MDV(±20%)<br />
200 N<br />
300 N<br />
Cold bending MLV -15 °C -18 °C EN 1109<br />
Water pressure No leakage Pass Pass EN 1928<br />
Tensile properties Long<br />
(MDV ± 20 %)<br />
700 N/50 mm 1000 N/50 mm EN 12311-1<br />
Trans<br />
650 N/50 mm 1000 N/50 mm<br />
Elongation<br />
(MDV ± 20 %)<br />
Long<br />
(MDV ± 15)<br />
45 %<br />
18 %<br />
Trans<br />
(MDV ± 15)<br />
45 %<br />
18 %<br />
Static loading resistance MLV<br />
20 kg<br />
20 kg<br />
EN 12730<br />
Impact loading resistance MLV<br />
Peel resistance after After heat<br />
ageing<br />
After water:<br />
Shear resistance after After heat<br />
ageing<br />
Cold bending After heat<br />
After UV<br />
Dimensional stability Long<br />
MLV<br />
Trans<br />
MLV<br />
∅ 15 mm<br />
Max ∆ 20 %<br />
∅ 15 mm<br />
Max ∆ 20 %<br />
EN 12691<br />
EN 12316-1<br />
Max ∆ 20 % Max ∆ 20 %<br />
Max ∆ 20 % Max ∆ 20 % EN 12317-1<br />
Max ∆ 15 °C<br />
Max ∆ 15 °C<br />
0,2 %<br />
0,2 %<br />
Max ∆ 15 °C<br />
Max ∆ 15 °C<br />
0,3 %<br />
0,3 %<br />
EN 1109<br />
EN 1107-1
Type<br />
<strong>ETA</strong>G Paragraph<br />
IR2 4,8 × L + IR 82 × 40<br />
SFS INTEC<br />
IR2S 4,8 × L + IR 82 × 40<br />
SFS INTEC<br />
EHBDF2C 4.8xL + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
EVDF2C 4.8xL + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
EVDF2C 4.8xL + 82x40R SC<br />
LR <strong>ETA</strong>NCO<br />
VMS2C 4.8xL + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
EVF2C 4.8xL + 82x40R SC<br />
LR <strong>ETA</strong>NCO<br />
EVF2C 4.8xL + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
ISODRILL TT + Etancoplast<br />
T80x40<br />
LR <strong>ETA</strong>NCO<br />
EGB2C 4.8xL + Etancoplast<br />
T80x40<br />
LR <strong>ETA</strong>NCO<br />
ISODRILL TT + 82x40 R DF<br />
LR <strong>ETA</strong>NCO<br />
ISODRILL TH DF + 82x40 R DF<br />
LR <strong>ETA</strong>NCO<br />
Page 12 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
5.3.4.1<br />
Axial<br />
loading<br />
test<br />
(N)<br />
Annex 2<br />
Characteristics of fasteners<br />
5.3.4.2<br />
Unwinding<br />
5.3.4.3<br />
Mechanical<br />
resistance of<br />
sleeve<br />
5.3.7.1<br />
Resistance to<br />
corrosion of<br />
metallic<br />
fastenings,<br />
15 Kesternich<br />
cycles<br />
5.3.7.2<br />
Mechanical<br />
resistance after<br />
heat ageing of<br />
plastic<br />
fastenings<br />
Profiled steel deck<br />
1450 Pass Not relevant Pass (
Type<br />
Page 13 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
<strong>ETA</strong>G Paragraph<br />
IFP2 6,7 × L + IRP 82 × 40<br />
SFS INTEC<br />
TPR 6,3 × L + IRD 82 × 40<br />
SFS INTEC<br />
FASTOVIS 3036 TF + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
Rivet RER/PER + 82x40 R DF<br />
LR <strong>ETA</strong>NCO<br />
TI 6,3 × L + IRD 82 × 40<br />
SFS INTEC<br />
TI 6,3 × L + IF/IG C 82 × 40<br />
SFS INTEC<br />
DT 6,3 × L + IRD 82 × 40<br />
SFS INTEC<br />
BETOFAST TH 3C + 82x40R<br />
LR <strong>ETA</strong>NCO<br />
BETOFAST TH DF 3C + 82x40R<br />
LR <strong>ETA</strong>NCO<br />
NAILFIX CH + 82x40 R SC<br />
LR <strong>ETA</strong>NCO<br />
BETOFAST TT 2C+ <strong>ETA</strong>NCOPLAST<br />
T80x40<br />
LR <strong>ETA</strong>NCO<br />
IGR S 8,0 × L + IG8 C 82 × 40<br />
SFS INTEC<br />
MULTIFAST TB INOX + 82x40R<br />
LR <strong>ETA</strong>NCO<br />
IG 6,0 × L + IRD 82 × 40<br />
SFS INTEC<br />
IWT 5.0 × L + IRC/W 82 × 40<br />
SFS INTEC<br />
MULTIFAST TF + 80x40R<br />
LR <strong>ETA</strong>NCO<br />
EVF2C 4.8xL + 82x40R SC<br />
LR <strong>ETA</strong>NCO<br />
EVDF2C 4.8xL + 82x40R DF<br />
LR <strong>ETA</strong>NCO<br />
EVDF2C 4.8xL + 82x40R SC<br />
LR <strong>ETA</strong>NCO<br />
5.3.4.1<br />
Axial<br />
loading<br />
test<br />
(N)<br />
5.3.4.2<br />
Unwinding<br />
5.3.4.3<br />
Mechanical<br />
resistance of<br />
sleeve<br />
5.3.7.1<br />
Resistance to<br />
corrosion of<br />
metallic<br />
fastenings,<br />
15 Kesternich<br />
cycles<br />
5.3.7.2<br />
Mechanical<br />
resistance after<br />
heat ageing of<br />
plastic<br />
fastenings<br />
Perforated profiled steel deck<br />
2600 Pass Not relevant Pass (
Material properties of the screws and fasteners:<br />
Page 14 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Screws<br />
• IR2 4.8xL: Hardened carbon steel screw. Double-thread, with a diameter of 4,8 mm, length L and with a 8 mm<br />
hexagonal head. Durocoat corrosion protection.<br />
• IR2S 4,8xL: Austenitic stainless steel A4 screw. Diameter of 4,8 mm, length L and with a 8 mm hexagon head.<br />
• IFP2 6,7xL: Hardened carbon steel screw. Double-thread, with a diameter of 6,7 mm, length L and with a 11 mm<br />
diameter flat head. Durocoat corrosion protection.<br />
• IWT 5xL: Hardened carbon steel screw. Diameter of 5 mm, length L and with a 9.5 mm diameter flat head.<br />
Duracoat corrosion protection.<br />
• IG 6xL: Hardened carbon steel screw. Diameter of 6 mm, length L and with a 8 mm diameter flat head. Duracoat<br />
corrosion protection.<br />
• IGR-S 8,0xL: Austenitic stainless steel A2 screw. Diameter of 8,0 mm, length L and with a 12 mm countersunk<br />
head.<br />
• TI 6,3xL: Hardened carbon steel screw. Diameter of 6,3 mm, length L and with a 8 mm hexagon head. Duracoat<br />
corrosion protection.<br />
• DT 6xL: Hardened carbon steel screw. Diameter of 6,3 mm, length L<br />
• IG 6xL: Hardened carbon steel screw. Diameter of 6 mm, length L and with a 8 mm diameter flat head. Duracoat<br />
corrosion protection.<br />
• EVF 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 12 mm circular head.<br />
Supracoat corrosion protection.<br />
• EVDF 2C 4.8xL: hardened carbon steel screws with double-thread under head, with a diameter of 4,8 mm, length L<br />
and with a 12 mm circular head. Supracoat corrosion protection.<br />
• EVBDF 2C: hardened carbon steel screws with double-thread under head, with a diameter of 4,8 mm, length L and<br />
with a 12 mm circular head. Supracoat corrosion protection.<br />
• EHBDF 2C 4.8xL: hardened carbon steel screw with double-thread under head, with a diameter of 4,8 mm, length<br />
L and with a 8 mm hexagonal head. Supracoat corrosion protection.<br />
• VMS 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 8.5 mm circular head.<br />
Supracoat corrosion protection.<br />
• EGB 2C 4.8xL: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 12 mm circular head.<br />
Supracoat corrosion protection.<br />
• ISODRILL TT: stainless steel screw. Diameter of 4,8 mm, length L and with a 8,5 mm circular head. A4 (1.4404)<br />
Stainless steel.<br />
• ISODRILL TH DF: Stainless steel screw with double-thread under head, with a diameter of 4,8 mm, length L and<br />
with a 8 mm hexagonal head. A4 (1.4304) stainless steel.<br />
• FASTOVIS 3036 TF 2C : hardened carbon steel screw. Diameter of 6,5 mm, length L and with a 11 mm<br />
cuntersunk head. Supracoat corrosion protection.<br />
• FASTOVIS 3036 TF DF 2C : hardened carbon steel screws with double-thread under head, with a diameter of 6,5<br />
mm, length L and with a 11 mm countersunk head. Supracoat corrosion protection.<br />
• PER and RER : Aluminium rivet. Diameter of 4,8 mm, length L and with a 10 mm circular head.<br />
• TPR 6,3xL : Aluminium rivet. Diameter of 6,3 mm, length L.<br />
• BETOFAST TH 3C: hardened carbon steel screw, with a diameter of 6,6 mm, length L and with a 8 mm hexagonal<br />
head. Supracoat corrosion protection.<br />
• BETOFAST TH DF 3C : hardened carbon steel screw with double-thread under head, with a diameter of 6,6 mm,<br />
length L and with a 8 mm hexagonal head. Supracoat corrosion protection.<br />
• BETOFAST TT 2C: hardened carbon steel screw. Diameter of 4,8 mm, length L and with a 8,5 mm circular head.<br />
Supracoat corrosion protection<br />
• NAILFIX CH: carbon steel nail diameter 4,8 mm, length L with a 10 circular head. Hot dip galvanized corrosion<br />
protection.<br />
• MULTIFAST TB INOX A2 : Stainless steel screw. Diameter of 6 mm, length L and with a 12 mm circular head.<br />
A2 (1.4301) stainless steel.<br />
• MULTIFAST TF : Stainless steel screw. Diameter of 6 mm, length L and with a 11 mm countersunk head. A2<br />
(1.4301) stainless steel.
Page 15 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Washers<br />
• 82x40 R DF: reinforced steel plate 82x40 mm, thickness 10/10e mm with punched inside cone. Hole Ø 5,1 mm.<br />
Aluzinc AZ 150 protection<br />
• 82x40 R: reinforced steel plate 82x40 mm, thickness 10/10e with punched inside cone. Hole Ø 6 mm. Aluzinc AZ<br />
150 protection<br />
• 82x40 R SC: reinforced steel plate 82x40 mm, thickness 10/10e mm. Hole Ø 6,4 mm. Aluzinc AZ 150 protection<br />
• IR 82x40, IRD 82x40, IRP 82x40, IF/IG C 82x40, IG8 C 82x40, IRC/W 82x40: steel plates with aluzinc<br />
protection, dimension 82x40 mm, thickness 1.00 mm<br />
• Etancoplast T 80x40: Ø 73x40 plastic plate with shaft<br />
Note In addition to the list of fasteners, other fasteners may also be used unless they are covered by a valid <strong>ETA</strong> and<br />
with rectangular plate with dimensions of 82X40 (as example, the fasteners of the <strong>ETA</strong> 08/0285 from AFAST BV –<br />
Guardian Fastening System- with plate size 82X40)
Page 16 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Annex 3<br />
Characteristics of the kit<br />
Membrane Fastener Wadm External fire performance<br />
DERBIGUM SP 4 FR See list in 1.1 784 N/Fastener Broof (t1)<br />
Field of application: see<br />
below<br />
Broof (t2)<br />
Field of application: see<br />
below<br />
Broof (t3)<br />
Field of application: see<br />
below<br />
DERBICOLOR 4 WSL See list in 1.1 784 N/Fastener Broof (t1)<br />
Field of application: see<br />
below<br />
Field of application for external fire performance<br />
Broof (t2)<br />
Field of application: see<br />
below<br />
Broof (t3)<br />
Field of application: see<br />
below<br />
The classification valid for the following conditions:<br />
• All pitches up to 20°<br />
• Range of decks: any wooden continuous deck with a minimum thickness of 16 mm and with gaps not exceeding<br />
5mm +/- 0.5 mm and any non-combustible continuous deck with a minimum thickness of 10 mm<br />
• Range of insulations: Combustible and non-combustible insulation materials with a density of at least 25 kg/m 3 and<br />
thickness at least 50 mm.<br />
• Mechanically fastened according to this <strong>ETA</strong><br />
Wadm was determined with a fastener with axial loading resistance Roc = 1458 N,<br />
To determine Wadm for other combinations (other substrate and other fastener) the following formula and conditions<br />
apply:<br />
If Rnc ≥ Roc then Wadm, nc = Wadm, oc<br />
If Rnc < Roc then Wadm, nc = (Rnc/Roc) × Wadm,oc<br />
The application of the full scale test results for systems with other fasteners (Rnc) and/or substrates according to annex 2<br />
of this <strong>ETA</strong>, a separate <strong>ETA</strong> or Fastener PASS issued on the basis of <strong>ETA</strong>G 0<strong>06</strong>, is possible if:<br />
• The plates are protected against corrosion;<br />
• The minimal thickness of the metallic plates is:<br />
o 0.75 mm, if they are ribbed,<br />
o 1.00 mm, if they are flat.<br />
In the new system, the use of plates that are different from those in the reference system is possible under the following<br />
conditions:<br />
• The steel plates are permitted with their resistance R determined in the whole system,
Page 17 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
• The metal grades and thicknesses are higher or equal to those of reference ones,<br />
• The dimensions of washers comply with the conditions in the following Table.<br />
Round washers<br />
Plates “nc”<br />
Square, rectangular or oblong<br />
Plates “oc”<br />
washers<br />
Round, Ø test Ø ≥ Ø test Width and length larger than or<br />
equal to the one tested<br />
Square, rectangular or<br />
Ø ≥ diagonal of washer tested Dimensions larger than or equal<br />
oblong<br />
oc = original combination (tested)<br />
nc = new combination<br />
to the one tested<br />
The fasteners have to be in conformity with the specifications given in section 1.1.2 and annex 2 of this <strong>ETA</strong>, an <strong>ETA</strong><br />
delivered on the basis on the <strong>ETA</strong>G 0<strong>06</strong> or a FASTENER PASS FOR MEFAWAME <strong>ETA</strong> – Intermediate evaluation in<br />
compliance with the <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> Guideline n°0<strong>06</strong>.
Page 18 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Annex 4<br />
Design and installation details<br />
Design and installation<br />
The suitability of this kit is valid only if the installation is carried out in accordance with the manufacturer’s<br />
instructions.<br />
The kit may be laid in conditions normal to roofing work and must not be laid in rain, snow or heavy fog, nor if the<br />
temperature falls below 2°C, unless specific precautions have been taken.<br />
Laying and overlaps<br />
The roll, with a nominal width of 110 or 55 cm, is aligned and unrolled in contact of the substrate. The DERBIGUM<br />
will always be placed with its glass fibre armature, of which the stripes are visible, upwards.<br />
The roll is then mechanically fixed with the fasteners and washers under the longitudinal overlaps (cfr Figure 1). The<br />
longitudinal overlaps between adjacent membranes are 130 mm ± 10 mm (min 120 mm), the end overlaps are 150 mm.<br />
Figure 1 : longitudinal overlap with mechanical fastener<br />
The crossing of the overlaps is done with a T-joint. The edge of the corner is cut at 45° (cfr Figure 2).<br />
Figure 2 : T-joint<br />
Overlaps must be then welded over their whole widths, the edges are then correctly pressed down. A small quantity of<br />
bitumen must be exuded from the overlap joint.
Page 19 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Fasteners<br />
The system is mechanically fastened in the overlaps by using prescribed fasteners (see chapter above). The position of<br />
the fastener in the overlap is shown on the figure 1 above.<br />
The calculation of the distance between fasteners and the number of fasteners per square meters on the different roof<br />
zones are determined according to the national Standards.<br />
The distance E between fasteners is determined by the formula E ≤ 1 / (D * Lr) with the following restrictive<br />
conditions:<br />
- Minimal distance between fasteners = 18 cm<br />
- Maximal distance between fasteners = 34 cm (or in accordance with national standards).<br />
With<br />
- D = minimal density of fasteners = Dp / Wadm of the “kit”<br />
- Lr = distance between fasteners rows (= width of the waterproofing sheet – width of the overlap; 97 cm for a<br />
110 cm sheet, 42 cm for a 55 cm sheet). Figure 5 below gives Lr values for several sheet laying.<br />
- Dp = Wind air pressure in the different roof zones (central, edge, corner,…) according to the national standards.<br />
If the calculated distance with a 110 cm sheet is E < 18 cm it is needed to adapt the laying of the system by either :<br />
- using sheets of 55 cm in width with fasteners in the longitudinal overlaps. See figure 3 below.<br />
- laying additional fasteners in a row at the middle of the sheet. Those fasteners are then recovered by a bridging<br />
stroke of width 20 cm in DERBIGUM fully torched. See figure 4 below.<br />
- Enlarge the width of the longitudinal overlaps > 130 mm.<br />
Figure 3 : half strokes Figure 4 : bridging strokes
Page 20 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Figure 5 : Distance between rows of fasteners<br />
Insulation<br />
The possibly laid insulation layer is constituted by thermal insulation boards appropriate for the use considered (see<br />
<strong>ETA</strong>G 0<strong>06</strong> chapter 5.4 and 6.4). They are loose laid on the possibly present vapour barrier. The mechanical fastening<br />
of the waterproofing system fastens the movement of the underlying layers to the deck. In some case (in function of<br />
insulation boards size and national standards) the insulation boards need to be independently fixed by 1 or 2 fasteners<br />
per boards that are not counted for in the density calculation for the mechanically fixed waterproofing. The insulation<br />
layer and the vapour barrier are realized according to the national standards.
Details<br />
Page 21 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
Upstands<br />
The waterproofing upstand on vertical surfaces is carried out according to the details 6 and 7. The realization detail<br />
(size of strokes, minimal upstand height) and the finishing at the top of the upstand (flashing, finishing profile, etc…)<br />
are in accordance with national recommendations.<br />
Examples of layout for the waterproofing upstand<br />
5<br />
3 4<br />
≥ 2 cm<br />
≥ 4 cm<br />
Figure 6 : Upstand with upperlying<br />
reinforcing strip<br />
h 2<br />
1. Substrate of the waterproofing sheet<br />
2. Waterproofing mechanically fixed<br />
3. Reinforcing strip fully torched<br />
4. Waterproofing upstand fully torched<br />
5. Finishing at the end of the waterproofing<br />
h minimum height : see national recommendations<br />
For the realization details : see national recommendations<br />
1<br />
5<br />
3 4<br />
≥ 2 cm ≥ 4 cm<br />
Figure 7 : Upstand with underlying<br />
reinforcing strip<br />
h 2<br />
Water outlet<br />
A recess is carried in the substrate or in the insulation board (in case of a warm roof buildup) around the water outlet,<br />
with a thickness difference of min 10 mm. See detail here below.<br />
1. Recess in the waterproofing substrate<br />
1<br />
Figure 8 : water outlet with fastened flange<br />
a<br />
5 3<br />
2<br />
4<br />
1
Page 22 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
2. Reinforcing piece in DERBIGUM<br />
3. Flange of the water outlet mechanically fixed at the corners<br />
4. Waterproofing mechanically fixed<br />
5. Grate<br />
a minimum width of the flange : see national recommendations<br />
For the realization details: see national recommendations<br />
Penetration fastening<br />
The waterproofing detail on punctual penetration are carried as shown in Figure 9.<br />
Figure 9 : Penetration fastening example<br />
1<br />
≥ 100 mm<br />
a<br />
6<br />
1. Substrate<br />
2. Waterproofing mechanically fixed<br />
3. Sleeve of the penetration (duct, tube, roof vent etc…) with flange mechanically fixed at the corners<br />
4. Fastener of the flange<br />
5. Waterproofing mechanically fixed<br />
6. Flashing<br />
a minimum width of the flange : see national recommendations<br />
Details relatives to some specific national recommendations<br />
Central valley with a zero slope<br />
1. Valley reinforcement ;<br />
- waterproofing mechanically fixed ; DERBIGUM SP 4 FR<br />
- or waterproofing mechanically fixed ; DERBICOLOR WSL returned<br />
3<br />
4<br />
5<br />
2
Page 23 of 23 of <strong>European</strong> <strong>Technical</strong> <strong>Approval</strong> no. <strong>ETA</strong>-<strong>06</strong>/<strong>0157</strong><br />
- or DERBICOAT HP (380N/fastener) with a line of additional fixation in the middle of the sheet, with the same<br />
spacing of fasteners as on the edge<br />
2. Waterproofing fully torched<br />
3. Waterproofing mechanically fixed<br />
Edge valley with a zero slope<br />
1. Reinforcement corner or strip<br />
2. Valley reinforcement ;<br />
- waterproofing mechanically fixed ; DERBIGUM SP 4 FR<br />
- or waterproofing mechanically fixed ; DERBICOLOR WSL<br />
- or DERBICOAT HP (380N/fastener) with a line of additional fixation in the middle of the sheet, with the same<br />
spacing of fasteners as on the edge<br />
3. Upstands fully torched